Catheter Robot Atlas

About

About the atlas

A discovery catalogue: each record describes a robot and links to its sources. Listing is descriptive and is not an endorsement.

Who maintains it

The BIRO Lab, New York University. Maintainers: [maintainer names]. Contact: [contact e-mail].

The maintainers built two of the catalogued robots: LegoBot and the portable catheter robot.

How the catalogue was built

  1. Two seed papers: LegoBot (IEEE/ASME T-MECH 2026) and the portable catheter robot (IEEE/ASME T-MECH 2025).
  2. Snowballing: the references of both seeds and the papers citing them and their predecessors gave 393 candidate papers.
  3. Logged searches by robot family, then gap searches for robots they missed, each query recorded with the coverage of the sources it reached (offline arXiv and dblp mirrors, then live bibliographic services), so "not found" is only said after a complete search.
  4. One row per robot line: versions merged, every number with its source key and section, full texts read where available, N.R. where a paper is silent.
  5. Pictures chosen from every paper of a robot's lineage, graded A/B/C, and shown here only when the licence allows.
SearchScopeRecords
academicSearch of academic bedside robots.28
commercialSearch of commercial and clinical-stage systems.24
actuated-tipSearch of actuated-tip and magnetic devices.28
gapGap searches for robots the other searches missed.46

The catalogue accompanies a review paper: Endovascular Catheter and Guidewire Robots: A Hardware Atlas (in preparation).

Licences

  • Site code (build scripts, validator, pages, styles): MIT.
  • Catalogue metadata (the records, the JSON and CSV files): [CC0 1.0 or CC BY 4.0 — maintainers to choose].
  • Pictures keep their owners' licences. Only pictures under CC BY (without NC, ND or SA) or our own material are published, with credit and a list of changes; all others are linked at their source.
  • Papers and products belong to their authors and companies. Listing is not an endorsement.

Picture credits

RobotSourceLicenceChanges
United Imagingsong2025_vascularpilot3d Fig. 5, top panel (arXiv 2405.09375v2, p. 5, native raster 1052 x 1462) ↗CC BY 4.0native extract; cropped to the top panel; nothing erased; none upscaled
Tianjin MR-fluidsong2023_masterslave Fig. 11(b) (developed slave equipment), Sensors 2023, image https://mdpi-res.com/sensors/sensors-23-03584/article_deploy/html/images/sensors-23-03584-g011.png ↗CC BY 4.0MDPI web image (1657x1196); cropped to panel (b); not upscaled; white dashed module boxes and labels on the robot left in place
Asan PCI robotchoi2021_vascular Fig. 12 (phantom setup for PCI), Biosensors 2021, image https://mdpi-res.com/biosensors/biosensors-11-00329/article_deploy/html/images/biosensors-11-00329-g012.png ↗CC BY 4.0MDPI web images (2815x1631, 3426x1310); main cropped, one leader line + its dot over the wall/pole and a text fragment at the edge removed (OpenCV Telea)
LegoBotBIRO Lab, New York University (own photograph)lab own (BIRO Lab, New York University)—
Portable robotBIRO Lab, New York University (own photograph)lab own (BIRO Lab, New York University)—
KCL lead-screwjackson2026_manual Fig. 2 (arXiv 2607.07253v1 HTML figure https://arxiv.org/html/2607.07253v1/Figs_robot_figure.png; page https://arxiv.org/html/2607.07253) ↗CC BY 4.0downloaded PNG 2888x989; cropped; letter tags a-e and their white arrows kept (arrows end on the frame and motors); not upscaled
Haptic wire robotmohammadi2026_haptic Fig. 8(a) (Ann Biomed Eng version 10.1007/s10439-026-04315-2; embedded 1500x1917) ↗CC BY 4.0native extract; cropped inside the panel border; panel letter 'a' erased (LaMa, on wood, not touching the robot); 12 px trimmed at top-left; not upscaled
ALLVAStian2026_visionlanguage (arXiv 2606.30698) Fig. 3(a), native image xref 313 with the authors' soft mask, p5 ↗CC BY 4.0 (both arXiv licences checked on arxiv.org/abs)full native image 777x690 with the authors' alpha, flattened on white; cut = authors' alpha (no SAM)
Raysight PCIliu2026_ai Fig. 1(b), MDPI full-resolution figure https://mdpi-res.com/bioengineering/bioengineering-13-00848/article_deploy/html/images/bioengineering-13-00848-g001.png (1796x1176; article https://www.mdpi.com/2306-5354/13/8/848) ↗CC BY 4.0cropped (78,662)-(882,1172) of the 1796x1176 MDPI image, i.e. panel (b) right of the panel letter; no erasing; not upscaled
Helical magneticdreyfus2024_dexterous accepted version (zenodo.org/records/10813540) Fig. 2 centre (eMNS beside the patient table, C-arm, advancer) ↗CC BY 4.0 (Zenodo record licence of the accepted manuscript; ETH Research Collection lists In Copyright for the same item)native extract (1332 px), circular inset fragments around the edge painted white, crop
CMNSli2024_multisection Fig. 1(B) embedded photo (CMNS with two UR arms, magnet, ultrasound probe and phantom; the figure's circles and labels are vector overlays and are not in the raster) ↗CC BY 4.0 (Cyborg Bionic Syst.; PMC open-access metadata licence_code CC BY)native extract from the PMC open-data PDF; no crop, no edits; not upscaled
7-T MRI steeringtiryaki2023_magnetic Fig. 1(A) (PMC10132757 figure file sciadv.adg6438-f1.jpg) ↗CC BY 4.0cropped panel A from the 785 px PMC figure; panel letter removed by crop; none upscaled
MFCRwang2023_magnetic Fig. 1(c), p. 3 ↗CC BY 4.0native embedded raster (two strips of 3418 px joined); cropped to panel (c), panel letter cropped off; labels 'Camera', 'MFCR', 'Magnetic System', 'Testbed' and their arrows kept (one arrow touches the MFCR); not upscaled
TUT catheter systemma2021_design Fig. 3 slave manipulator, https://cdn.ncbi.nlm.nih.gov/pmc/blobs/69b3/7861939/0d63d0cf83e2/ABB2021-8898311.003.jpg (page https://pmc.ncbi.nlm.nih.gov/articles/PMC7861939/) ↗CC BY (Creative Commons Attribution License, as stated)PMC image as served; no edits; not upscaled
Soochow robotyang2023_interventional Fig. 1 right panel, https://mdpi-res.com/applsci/applsci-13-05301/article_deploy/html/images/applsci-13-05301-g001.png (page https://www.mdpi.com/2076-3417/13/9/5301) ↗CC BY 4.0cropped to the slave photo; not upscaled
CIOMP isomorphicchen2025_design Fig. 1 centre panel, https://mdpi-res.com/actuators/actuators-14-00029/article_deploy/html/images/actuators-14-00029-g001.png (page https://www.mdpi.com/2076-0825/14/1/29) ↗CC BY 4.0cropped to the grey render panel; not upscaled
KAIST feederbaek2022_design Fig. 14(c), OUP view-large image qwac065fig14.jpeg (page https://academic.oup.com/jcde/article/9/4/1467/6660650) ↗CC BYcropped to panel (c) above the 'drape' label; not upscaled
CathROBcercenelli2017_cathrob Fig. 2(b) top (Motion Unit on articulated arm), native embedded image on PDF p. 3 from the PMC open-access PDF ↗CC BY 4.0native extract (1586 x 1320); cropped to Motion Unit and upper arm; no erasing (labels were vector overlays outside the bitmap); not upscaled (upscale disabled)
ROSESdanieli2022_development Fig. 12, centre unit (robot actuator, second edition); https://mdpi-res.com/applmech/applmech-03-00054/article_deploy/html/images/applmech-03-00054-g012.png (article https://doi.org/10.3390/applmech3030054) ↗CC BY 4.0full-size MDPI figure image; cropped to the centre unit; not upscaled
Caranx TAVI robotsmits2025_tavi_FRAI Fig. 2 (left panel, in-vivo set-up 15 Mar 2024), robotic instrument manipulator region ↗CC BY 4.0the PDF splits the photo into 3 raster tiles (705x430, 705x288, 284x715): stitched at native size (no vector annotations included), cropped to the manipulator
CardioXplorerxu2024_cardioxplorer_Robotics Fig. 4 left photo (SmartTouch SF catheter in the catheter-agnostic gripper); full-size image https://mdpi-res.com/robotics/robotics-13-00080/article_deploy/html/images/robotics-13-00080-g004.png ↗CC BY 4.0cropped from the 3155x1185 MDPI full-size figure (caption text below the photo excluded); no other edits; not upscaled
RVIR-CI / RobEnt galleryDraped slave on the angiography table during the first-patient angiography (RobEnt). Jiang et al., Applied Bionics and Biomechanics (2018), Fig. 3, PMC5926525 (former main picture of robent_jiang2018, patient area cropped) ↗CC BY (Creative Commons Attribution License, version not stated in the article XML)cropped to the panel; resized
RVIR-CI / RobEnt galleryMaster console with two haptic devices and the slave on the angiography table (RobEnt). Jiang et al., Applied Bionics and Biomechanics (2018), Fig. 1, PMC5926525 ↗CC BY (Creative Commons Attribution License)cropped to the panel; resized
RVIR-CI / RobEnt gallerySlave grippers holding catheter and guidewire under the sterile drape (RobEnt). Jiang et al., Applied Bionics and Biomechanics (2018), Fig. 2, PMC5926525 ↗CC BY (Creative Commons Attribution License)cropped to the panel; resized
RVIR-CI / RobEnt galleryPhysician at the draped slave and operator at the master console during the first patient (RobEnt). Jiang et al., Applied Bionics and Biomechanics (2018), Fig. 4(a), left photos, p. 4 ↗CC BY (Creative Commons Attribution License, version not stated)cropped to the panel; resized
RVIR-CI / RobEnt galleryPhysician beside the draped slave during the first-in-human angiography (RobEnt). Jiang et al., Applied Bionics and Biomechanics (2018), Fig. 5, p. 4 ↗CC BY (Creative Commons Attribution License, version not stated)cropped to the panel; resized
RVIR-CI / RobEnt gallerySlave manipulator arm on the angiography table, draped, with the console screens behind (RobEnt). Liu et al., Applied Bionics and Biomechanics (2021), Fig. 1, p. 4 (three image tiles, page region rendered at 300 dpi) ↗CC BY (Creative Commons Attribution License, version not stated)cropped to the panel; resized
RVIR-CI / RobEnt galleryGear grippers of the slave arm holding the guidewire under the drape (RobEnt). Liu et al., Applied Bionics and Biomechanics (2021), Fig. 2, p. 4 ↗CC BY (Creative Commons Attribution License, version not stated)cropped to the panel; resized
RVIR-CI / RobEnt galleryJoint between the slave arm and the femoral sheath of the pig (RobEnt). Liu et al., Applied Bionics and Biomechanics (2021), Fig. 4, p. 4 ↗CC BY (Creative Commons Attribution License, version not stated)cropped to the panel; resized
RVIR-CI / RobEnt galleryBama miniature pig on the table with the slave arm and the team (RobEnt). Liu et al., Applied Bionics and Biomechanics (2021), Fig. 3, p. 4 (two image tiles, page region rendered at 300 dpi) ↗CC BY (Creative Commons Attribution License, version not stated)cropped to the panel; resized
RVIR-CI / RobEnt gallerySlave manipulator of the string-driven version: driver modules and clamps on one rail. Zhou et al., Micromachines (2022), Fig. 4 (MDPI HTML figure g004; former main picture of bit_stringdriven_zhou2022, labels removed) ↗CC BY 4.0cropped to the panel; resized
RVIR-CI / RobEnt gallerySlave clamps and driver modules, master manipulator and vascular model (string-driven version). Zhou et al., Micromachines (2022), Fig. 8 (MDPI HTML figure g008) ↗CC BY 4.0cropped to the panel; resized
RVIR-CI / RobEnt galleryMaster manipulator CAD with force-feedback assemblies and its circuit board (string-driven version). Zhou et al., Micromachines (2022), Fig. 3 (MDPI HTML figure g003) ↗CC BY 4.0cropped to the panel; resized
RAECS / ECRS galleryECRS slave with catheter and guidewire manipulation units on a slide rail. Li et al., Micromachines (2022), Fig. 3 (MDPI HTML figure g003) ↗CC BY 4.0cropped to the panel; resized
RAECS / ECRS galleryMR-fluid haptic master: magnetic field generator around the input catheter. Yin et al., Micromachines (2018), Fig. 11 (MDPI HTML figure g011) ↗CC BY 4.0cropped to the panel; resized
RAECS / ECRS galleryMR-fluid master with encoders for translation and rotation of the catheter. Zhang et al., Micromachines (2021), Fig. 3 (MDPI HTML figure g003) ↗CC BY 4.0cropped to the panel; resized
RAECS / ECRS gallerySlave manipulator with load cell and sliding table for force calibration. Zhang et al., Micromachines (2021), Fig. 13 (MDPI HTML figure g013) ↗CC BY 4.0cropped to the panel; resized
RAECS / ECRS gallerySlave manipulator robot driving devices into the EVE vascular model. Li et al., Micromachines (2022), Fig. 15(b) (MDPI HTML figure g015) ↗CC BY 4.0cropped to the panel; resized
RAECS / ECRS galleryMRF master interface and slave manipulator with force sensor on the bench. Zhang et al., Sensors (2025), Fig. 12 (MDPI HTML figure g012) ↗CC BY 4.0cropped to the panel; resized
RAECS / ECRS galleryCAD of the ECRS slave with catheter and guidewire operating units. Li et al., Micromachines (2022), Fig. 2 (MDPI HTML figure g002) ↗CC BY 4.0cropped to the panel; resized
SIAT haptic robot galleryPrimary console shown in four guidewire manipulation patterns. Du et al., IEEE Transactions on Human-Machine Systems (2024), Fig. 1, p. 3 ↗CC BY 4.0cropped to the panel; resized
United Imaging galleryRobot and vascular phantom on the angiography table. Song et al., 2025 IEEE International Conference on Robotics and Automation (ICRA) (2025), Fig. 5 (middle left), p. 5, arXiv 2405.09375v2 ↗CC BY 4.0cropped to the panel; resized
Tianjin MR-fluid galleryMaster manipulator, controller boards and slave manipulator with EVE model. Song et al., Sensors (2023), Fig. 17 (left part) (MDPI HTML figure g017) ↗CC BY 4.0cropped to the panel; resized
Tianjin MR-fluid galleryMaster manipulator coupled to force sensors for calibration. Song et al., Sensors (2023), Fig. 13 (MDPI HTML figure g013) ↗CC BY 4.0cropped to the panel; resized
Tianjin MR-fluid galleryPrototype of the MR-fluid master manipulator. Song et al., Sensors (2023), Fig. 3(b) (MDPI HTML figure g003) ↗CC BY 4.0cropped to the panel; resized
Tianjin MR-fluid galleryCAD of the slave: friction wheels, electromagnet and guidewire clamp. Song et al., Sensors (2023), Fig. 11(a) (MDPI HTML figure g011) ↗CC BY 4.0cropped to the panel; resized
Asan PCI robot galleryClinical prototype: master console with haptic device and slave robot end-effector. Choi et al., Biosensors (2021), Fig. 5 ↗CC BY 4.0cropped to the panel; resized
Asan PCI robot galleryClinical trial: team at the table and operator at the master console. Choi et al., Biosensors (2021), Fig. 17 ↗CC BY 4.0cropped to the panel; resized
Asan PCI robot galleryRoller module with EM tracker and Aurora field generator beside a phantom. Choi et al., Biosensors (2021), Fig. 11 ↗CC BY 4.0cropped to the panel; resized
Asan PCI robot galleryRenderings of the slave side and master side with labelled parts. Choi et al., Biosensors (2021), Fig. 1 ↗CC BY 4.0cropped to the panel; resized
Asan PCI robot galleryCAD of the end-effector modules for guidewire, catheter and balloon. Choi et al., Biosensors (2021), Fig. 2 ↗CC BY 4.0cropped to the panel; resized
Asan PCI robot galleryCAD of the bi-motional roller cartridge, roller module and clamping drive. Choi et al., Biosensors (2021), Fig. 3 ↗CC BY 4.0cropped to the panel; resized
Asan PCI robot galleryCAD of the haptic master device: spherical, linear and planar mechanisms. Choi et al., Biosensors (2021), Fig. 4 ↗CC BY 4.0cropped to the panel; resized
Asan PCI robot galleryCatheter steered to two targets in a vascular phantom, image sequence. Choi et al., Biosensors (2021), Fig. 13 ↗CC BY 4.0cropped to the panel; resized
LegoBot galleryThree-module robot driving devices into a neurovascular phantom, gamepad and GUI. Gao et al., IEEE/ASME Transactions on Mechatronics (2026), lab photo IMG_4635.jpg, unannotated original of Fig. 2 ↗lab own (collaborator material)cropped to the panel; resized
LegoBot gallerySingle guide-catheter module with catheter loaded, gear train visible through window. Gao et al., IEEE/ASME Transactions on Mechatronics (2026), lab video IMG_4651.MOV still, t = 0.67 s ↗lab own (collaborator material)cropped to the panel; resized
Portable robot galleryTop module with guide-catheter clamp, rotation gear, lead screw and rails. Kantu et al., IEEE/ASME Transactions on Mechatronics (2025), lab photo image50.jpg, unannotated original of Fig. 4(b) ↗lab own (collaborator material)cropped to the panel; resized
Portable robot galleryRobot with top covers on feeding a guide catheter toward a heart model. Kantu et al., IEEE/ASME Transactions on Mechatronics (2025), lab video poster frame image18.png, PCI lecture deck ↗lab own (collaborator material)cropped to the panel; resized
CathBot galleryIn-vivo porcine trial: remote manipulator on mounting arm, master in control room. Dagnino et al., IEEE Transactions on Biomedical Engineering (2023), Fig. 2(A)-(D), p. 2 ↗CC BY 4.0cropped to the panel; resized
CathBot galleryMR-safe slave robot driving devices into an aortic phantom under fluoroscopy. Kundrat et al., IEEE Transactions on Biomedical Engineering (2021), Fig. 4(b), p. 6 ↗CC BY 4.0cropped to the panel; resized
CathBot galleryRendered platform: valve manifold, pneumatic tubing, master device and remote manipulator. Dagnino et al., IEEE Transactions on Biomedical Engineering (2023), Fig. 1, p. 2 ↗CC BY 4.0cropped to the panel; resized
CathBot galleryCAD side view of catheter and guidewire drivers with quick-release lid details. Kundrat et al., IEEE Transactions on Biomedical Engineering (2021), Fig. 3(b), p. 4 ↗CC BY 4.0cropped to the panel; resized
CathBot galleryHaptic master device with the navigation user interface in the control room. Kundrat et al., IEEE Transactions on Biomedical Engineering (2021), Fig. 4(a), p. 6 ↗CC BY 4.0cropped to the panel; resized
CathBot galleryMaster device prototype opened: belt drive, rotary and linear motors, force sensor. Kundrat et al., IEEE Transactions on Biomedical Engineering (2021), Fig. 2(b), p. 3 ↗CC BY 4.0cropped to the panel; resized
KCL lead-screw galleryLead-screw manipulator beside a vascular phantom on the table under a mobile C-arm. Robertshaw et al. (2026), Fig. 2, p. 3 (arXiv 2604.20151v1) ↗CC BY 4.0cropped to the panel; resized
KCL lead-screw galleryLong concentric-tube manipulator: lead-screw guide rail, telescopic tubes, actuation units. Robertshaw et al., IEEE Robotics and Automation Letters (2026), Fig. 3, p. 4 (arXiv 2602.18663v1) ↗CC BY 4.0cropped to the panel; resized
KCL lead-screw galleryRobot and force-sensing phantom under a mobile C-arm in a mock angiography suite. Jackson et al. (2026), Fig. 4(a), p. 4 (arXiv 2607.07253v1) ↗CC BY 4.0cropped to the panel; resized
KCL lead-screw galleryDevice-mimicking haptic controller: handle, brushless motors, mode buttons. Jackson et al. (2026), Fig. 1, p. 2 (arXiv 2607.07253v1) ↗CC BY 4.0cropped to the panel; resized
KCL lead-screw galleryNeuroradiologist teleoperating the robot from the control room. Jackson et al. (2026), Fig. 4(b), p. 4 (arXiv 2607.07253v1) ↗CC BY 4.0cropped to the panel; resized
Wire manipulator galleryEx-vivo porcine liver bench with guidewire manipulator, C-arm, pump and gamepad. Karstensen et al., International Journal of Computer Assisted Radiology and Surgery (2022), Fig. 3(c), p. 5 ↗CC BY 4.0cropped to the panel; resized
Wire manipulator gallery2020 test bench: 2-DOF manipulator housing, lit 2D phantom, camera and gamepad. Karstensen et al., Current Directions in Biomedical Engineering (2020), Fig. 1, p. 2 ↗CC BY 4.0cropped to the panel; resized
Wire manipulator gallery2020 bench: the 2-DOF guidewire manipulator in its housing beside the camera-tracked vessel phantom and a gamepad for manual control (labelled figure). Karstensen et al., Current Directions in Biomedical Engineering (2020), Fig. 1, p. 2 (embedded 972x728) ↗CC BY 4.0cropped to the panel; resized
Haptic wire robot galleryRobot feeding a guidewire into the modular artificial-artery testbed with stenosis. Mohammadi et al., Annals of Biomedical Engineering (2026), Fig. 9(b), p. 11 ↗CC BY 4.0cropped to the panel; resized
Haptic wire robot galleryCAD overview: main Dynamixel servo, three miniature servos, belt and wire guide. Mohammadi et al., Annals of Biomedical Engineering (2026), Fig. 3(a), p. 5 ↗CC BY 4.0cropped to the panel; resized
Haptic wire robot galleryCAD of the gripper-belt advance cycle and rack-and-pinion rotation. Mohammadi et al., Annals of Biomedical Engineering (2026), Fig. 2(a)-(d), p. 4 ↗CC BY 4.0cropped to the panel; resized
Haptic wire robot galleryCAD of the assembled testbed rack with the robot installed. Mohammadi et al., Annals of Biomedical Engineering (2026), Fig. 7(c), p. 9 ↗CC BY 4.0cropped to the panel; resized
SENTANTE galleryBedside unit cassettes holding three endovascular devices, close view. Huistra et al., CardioVascular and Interventional Radiology (2026), Fig. 1(B), p. 3 ↗CC BY 4.0cropped to the panel; resized
SENTANTE galleryRemote workstation and the operator moving the input device by hand. Huistra et al., CardioVascular and Interventional Radiology (2026), Fig. 2, p. 4 ↗CC BY 4.0cropped to the panel; resized
SENTANTE galleryWorkstation INFLATE unit for remote balloon inflation and contrast injection. Huistra et al., CardioVascular and Interventional Radiology (2026), Fig. 3, p. 4 ↗CC BY 4.0cropped to the panel; resized
Navion galleryElectromagnetic navigation system beside the procedure table and C-arm in Zurich. Madder et al., JACC: Advances (2025), Fig. 1 (left), PMC11719301 ↗CC BY 4.0cropped to the panel; resized
Navion galleryGamepad controller with labelled catheter, guidewire and field-steering inputs. Madder et al., JACC: Advances (2025), Fig. 1 (right), PMC11719301 ↗CC BY 4.0cropped to the panel; resized
ALLVAS galleryDraped mechanical arms carrying the rotatable gripper relays. Chen et al. (2026), Fig. 2, arXiv p. 3 ↗CC BY 4.0cropped to the panel; resized
ALLVAS galleryFunctional unit: renderings and a photograph beside the angiography table. Song et al., European Radiology (2023), Fig. 1, p. 3 ↗CC BY 4.0cropped to the panel; resized
ALLVAS galleryRendering of the interventional console with monitors and control panels. Song et al., European Radiology (2023), Fig. 2, p. 3 ↗CC BY 4.0cropped to the panel; resized
ALLVAS galleryRenderings of the grippers rotating through four motion states. Song et al., European Radiology (2023), Fig. 5, p. 8 ↗CC BY 4.0cropped to the panel; resized
ALLVAS galleryRendering of the two mechanical arms with gripper ends. Tian et al. (2026), Fig. 3(b), arXiv p. 5 ↗CC BY 4.0cropped to the panel; resized
ALLVAS galleryBionic design: two three-axis arms with four manipulators and grippers (labelled). Song et al., Micromachines (2022), Fig. 2(a-c), p. 4 ↗CC BY 4.0cropped to the panel; resized
ALLVAS galleryRendering of the coaxial manipulators clamping a stent-graft system. Song et al., Micromachines (2022), Fig. 3(b), p. 6 ↗CC BY 4.0cropped to the panel; resized
ALLVAS galleryRobot grippers at the table beside the angiograms of five porcine procedure types. Song et al., Micromachines (2022), Fig. 8(a-e), p. 13 ↗CC BY 4.0cropped to the panel; resized
Raysight PCI galleryRendering of the Raysight robot on the patient table beside a C-arm. Liu et al., Bioengineering (2026), Fig. 1(a), PMC13509165 ↗CC BY 4.0cropped to the panel; resized
Helical magnetic galleryHelical robot navigating trans-radial, trans-femoral and aneurysm phantom routes. Dreyfus et al., Science Robotics (2024), Fig. 5(B-E), accepted version p. 31 ↗CC BY 4.0 (Zenodo 10813540 accepted version)cropped to the panel; resized
Helical magnetic galleryDrawing of the helical guidewire, microcatheter and motorized advancer. Dreyfus et al., Science Robotics (2024), Fig. 3, accepted version p. 29 ↗CC BY 4.0 (Zenodo 10813540 accepted version)cropped to the panel; resized
Helical magnetic galleryExploded drawing of the advancer: friction drive wheel, guiding insert, motor. Dreyfus et al., Science Robotics (2024), Fig. S1, accepted version p. 38 ↗CC BY 4.0 (Zenodo 10813540 accepted version)cropped to the panel; resized
Magnet gantry gallery2023 system concept: arm-held magnet on a mobile cart, wire/catheter advancer, console (labelled). Fu et al., Advanced Intelligent Systems (2023), Fig. 1(b), p. 3 ↗CC BY (Creative Commons Attribution License, version not printed)cropped to the panel; resized
Magnet gantry galleryIn-vitro setup: arm-held magnet, pulsatile pumps, 3D phantom and guidewire advancer (labelled). Fu et al., Advanced Intelligent Systems (2023), Fig. 5(a), p. 12 ↗CC BY (Creative Commons Attribution License, version not printed)cropped to the panel; resized
Magnet gantry gallerySystem on a mobile cart beside the bed under DSA in a catheterisation room. Fu et al., Advanced Intelligent Systems (2023), Fig. 6(a), p. 13 ↗CC BY (Creative Commons Attribution License, version not printed)cropped to the panel; resized
Magnet gantry galleryTrajectory-following platform: arm-held magnet, phantom, cameras and guidewire advancer (labelled). Fu et al., Advanced Intelligent Systems (2023), Fig. 4(a), p. 10 ↗CC BY (Creative Commons Attribution License, version not printed)cropped to the panel; resized
CMNS galleryTwo UR arms with magnet and ultrasound transducer over a soft anthropomorphic phantom. Li et al., Cyborg and Bionic Systems (2024), Fig. 8(A), p. 11 ↗CC BY 4.0cropped to the panel; resized
CMNS galleryAutonomous navigation through a 3D ring path: setup and snapshot sequence. Li et al., Cyborg and Bionic Systems (2024), Fig. 7, p. 11 ↗CC BY 4.0cropped to the panel; resized
CMNS galleryCollaborative multirobot navigation system: arm kinematics, whole system, US tracking. Li et al., Cyborg and Bionic Systems (2024), Fig. 4, p. 7 ↗CC BY 4.0cropped to the panel; resized
Milli-spinner galleryRotating magnet on a robot arm driving the spinner through a head-model flow phantom. Wu et al., Advanced Materials (2025), Fig. 2(h-j), p. 3 ↗CC BY (Creative Commons Attribution License)cropped to the panel; resized
Milli-spinner galleryFluoroscopy-guided navigation setup in an angiography suite with the flow model. Wu et al., Advanced Materials (2025), Fig. 2(e-f), p. 3 ↗CC BY (Creative Commons Attribution License)cropped to the panel; resized
Milli-spinner galleryOptimized milli-spinner design drawing with photos of the printed spinner. Lu et al., Advanced Robotics Research (2026), Fig. 8(a), p. 9 ↗CC BY (Creative Commons Attribution License)cropped to the panel; resized
7-T MRI steering galleryGuidewire steering in renal, arch, carotid and cerebral glass models. Tiryaki et al., Science Advances (2023), Fig. 7 ↗CC BY 4.0cropped to the panel; resized
7-T MRI steering galleryObstacle tasks with three tip-magnet configurations inside the 7-T scanner. Tiryaki et al., Science Advances (2023), Fig. 5 ↗CC BY 4.0cropped to the panel; resized
MFCR galleryMFCR in J and S modes passing an obstacle into a branch under the electromagnet system. Wang et al., Actuators (2023), Fig. 6, p. 8 ↗CC BY 4.0cropped to the panel; resized
MFCR galleryMFCR turning through 30-130 degree ring channels and aorta-coronary models. Wang et al., Actuators (2023), Fig. 5, p. 7 ↗CC BY 4.0cropped to the panel; resized
Beihang VIR galleryCAD of the MIVI robot: bionic fingers, clamping and rotation motors. Guan et al., BMC Surgery (2023), Fig. 5(a), p. 4 ↗CC BY 4.0cropped to the panel; resized
Beihang VIR galleryCatheter navigated to four target positions in a bifurcation phantom. Guan et al., BMC Surgery (2023), Fig. 6, p. 4 ↗CC BY 4.0cropped to the panel; resized
Beihang VIR galleryBionic-finger catheter driver (COR / MIVI robot) during a rotation test. Guan et al., BMC Surgery (2023), Fig. 5(b), p. 4 (previous main picture; the same photo is meng2016_novel Fig. 5) ↗CC BY 4.0cropped to the panel; resized
TUT catheter system galleryMaster end manipulator: encoders on the catheter held by the surgeon. Ma et al., Applied Bionics and Biomechanics (2021), Fig. 4 (PMC7861939 figure 004) ↗CC BY (Creative Commons Attribution License, as stated)cropped to the panel; resized
TUT catheter system gallerySlave end console with two graspers, load cell and torque sensor. Ma et al., Applied Bionics and Biomechanics (2021), Fig. 7 (PMC7861939 figure 007) ↗CC BY (Creative Commons Attribution License, as stated)cropped to the panel; resized
TUT catheter system gallerySurgeon's console: hollow encoder, couplings and shaft holders. Ma et al., Applied Bionics and Biomechanics (2021), Fig. 6 (PMC7861939 figure 006) ↗CC BY (Creative Commons Attribution License, as stated)cropped to the panel; resized
TUT catheter system gallery2020 system: main end handle stage and slave end on its inclined stand. Ma et al., Applied Bionics and Biomechanics (2020), Fig. 1 (PMC7775165 figure 001) ↗CC BY (Creative Commons Attribution License, as stated)cropped to the panel; resized
TUT catheter system galleryAxial force measurement mechanism: catheter frame, clamp plate, load cell. Ma et al., Applied Bionics and Biomechanics (2020), Fig. 4 (PMC7775165 figure 004) ↗CC BY (Creative Commons Attribution License, as stated)cropped to the panel; resized
Soochow robot gallerySlave with DC motors, encoders, guidewire and catheter clamping modules. Yang et al., Applied Sciences (2023), Fig. 2 (MDPI HTML figure g002) ↗CC BY 4.0cropped to the panel; resized
Soochow robot galleryCatheter manipulator and guidewire manipulator on the slave rail. Wei et al., Machines (2022), Fig. 2 (MDPI HTML figure g002) ↗CC BY 4.0cropped to the panel; resized
Soochow robot galleryCAD of the clamping module: gears, DC motor, sensor and steering engine. Yang et al., Applied Sciences (2023), Fig. 3 (MDPI HTML figure g003) ↗CC BY 4.0cropped to the panel; resized
Soochow robot galleryForce sensor mounted on the module slideway. Yang et al., Applied Sciences (2023), Fig. 5 (MDPI HTML figure g005) ↗CC BY 4.0cropped to the panel; resized
Soochow robot galleryResistance sensing in the catheter module, CAD and photos. Wei et al., Machines (2022), Fig. 3 (MDPI HTML figure g003) ↗CC BY 4.0cropped to the panel; resized
Soochow robot galleryCAD of the force-sensing slideway under the clamping module. Yang et al., Applied Sciences (2023), Fig. 4 (MDPI HTML figure g004) ↗CC BY 4.0cropped to the panel; resized
Soochow robot galleryCatheter tip with thin-film strain gauges. Wei et al., Machines (2022), Fig. 8 (MDPI HTML figure g008) ↗CC BY 4.0cropped to the panel; resized
Soochow robot galleryMaster manipulator with two control knobs and touch screen. Yang et al., Applied Sciences (2023), Fig. 1 (left part) (MDPI HTML figure g001) ↗CC BY 4.0cropped to the panel; resized
CIOMP isomorphic galleryLeader robot, follower robot, camera and IPC on the test bench. Chen et al., Actuators (2025), Fig. 4(a) (MDPI HTML figure g004) ↗CC BY 4.0cropped to the panel; resized
CIOMP isomorphic galleryCAD close-ups: catheter delivery, catheter rotation and guidewire mechanisms. Chen et al., Actuators (2025), Fig. 1 (bottom row) (MDPI HTML figure g001) ↗CC BY 4.0cropped to the panel; resized
HKU MR-safe robot galleryRobotic catheter platform at the 1.5T MRI scanner with LA phantom. Dong et al., IEEE Transactions on Robotics (2022), Fig. 15(a), p. 14 ↗CC BY 4.0cropped to the panel; resized
HKU MR-safe robot galleryMR-safe slave with three-cylinder actuation unit, master part behind the wave guide. Dong et al., IEEE Transactions on Robotics (2022), Fig. 6, p. 8 ↗CC BY 4.0cropped to the panel; resized
KAIST feeder galleryCatheter driving unit with the feeder in the buckling-prevention test. Baek et al., Journal of Computational Design and Engineering (2022), Fig. 9(c) (OUP figure qwac065fig9) ↗CC BY (OUP open access, oa=CC BY)cropped to the panel; resized
KAIST feeder galleryFeeder prototype and disposable roller module prototype. Baek et al., Journal of Computational Design and Engineering (2022), Fig. 14(a)-(b) (OUP figure qwac065fig14) ↗CC BY (OUP open access, oa=CC BY)cropped to the panel; resized
KAIST feeder galleryFeeder at the distal end of the catheter-driving unit. Baek et al., Journal of Computational Design and Engineering (2022), Fig. 1 (OUP figure qwac065fig1) ↗CC BY (OUP open access, oa=CC BY)cropped to the panel; resized
KAIST feeder galleryInsertion-force test of the feeder with load cell and drape. Baek et al., Journal of Computational Design and Engineering (2022), Fig. 9(a) (OUP figure qwac065fig9) ↗CC BY (OUP open access, oa=CC BY)cropped to the panel; resized
KAIST feeder galleryDesign of the 2-DOF feeder: motors, driving shafts, cross-section. Baek et al., Journal of Computational Design and Engineering (2022), Fig. 3 (OUP figure qwac065fig3) ↗CC BY (OUP open access, oa=CC BY)cropped to the panel; resized
KAIST feeder galleryDisposable roller module and its exploded view with the drape. Baek et al., Journal of Computational Design and Engineering (2022), Fig. 4 (OUP figure qwac065fig4) ↗CC BY (OUP open access, oa=CC BY)cropped to the panel; resized
CathROB galleryDraped Motion Unit on its arm prepared for the in-vivo animal study. Cercenelli et al., Applied Bionics and Biomechanics (2017), Fig. 9, p. 9 ↗CC BY 4.0 (Hindawi; PDF states 'Creative Commons Attribution License')cropped to the panel; resized
CathROB galleryIn-vitro set-up: arm-mounted Motion Unit feeding a catheter into a vascular model. Cercenelli et al., Applied Bionics and Biomechanics (2017), Fig. 8(a), p. 8 ↗CC BY 4.0 (Hindawi; PDF states 'Creative Commons Attribution License')cropped to the panel; resized
CathROB galleryWhole system: arm-mounted Motion Unit, GUI monitor, control box and push-button box. Cercenelli et al., Applied Bionics and Biomechanics (2017), Fig. 2(b), p. 3 ↗CC BY 4.0 (Hindawi; PDF states 'Creative Commons Attribution License')cropped to the panel; resized
CathROB galleryMotion Unit holding an EP catheter handle, with clamp insets. Cercenelli et al., Applied Bionics and Biomechanics (2017), Fig. 3, p. 4 ↗CC BY 4.0 (Hindawi; PDF states 'Creative Commons Attribution License')cropped to the panel; resized
CathROB galleryDisassembled Motion Unit, supporting arm, anchoring plate and cable. Cercenelli et al., Applied Bionics and Biomechanics (2017), Fig. 4, p. 4 ↗CC BY 4.0 (Hindawi; PDF states 'Creative Commons Attribution License')cropped to the panel; resized
CathROB galleryHandle adapters fitting four commercial tip-steerable EP catheters. Cercenelli et al., Applied Bionics and Biomechanics (2017), Fig. 5, p. 5 ↗CC BY 4.0 (Hindawi; PDF states 'Creative Commons Attribution License')cropped to the panel; resized
CathROB galleryCommand interface: mock catheter handle and push-button box. Cercenelli et al., Applied Bionics and Biomechanics (2017), Fig. 6, p. 6 ↗CC BY 4.0 (Hindawi; PDF states 'Creative Commons Attribution License')cropped to the panel; resized
CathROB gallery3D rendering of the system attached to a cath-lab table by an articulated arm. Cercenelli et al., Applied Bionics and Biomechanics (2017), Fig. 1, p. 2 ↗CC BY 4.0 (Hindawi; PDF states 'Creative Commons Attribution License')cropped to the panel; resized
ROSES galleryFirst patient case: operator at the ROSES console, robot actuator on the table. Danieli et al., Applied Mechanics (2022), Fig. 9(a), p. 6 ↗CC BY 4.0cropped to the panel; resized
ROSES galleryFirst ROSES prototype ever built, on a wooden bench. Danieli et al., Applied Mechanics (2022), Fig. 1, p. 2 ↗CC BY 4.0cropped to the panel; resized
ROSES galleryDisposable actuator closed and open, showing four friction wheels and spur gears. Danieli et al., Applied Mechanics (2022), Fig. 6, p. 5 ↗CC BY 4.0cropped to the panel; resized
ROSES galleryEarly in vitro trial under X-ray with PVC tubing on the angiography table. Danieli et al., Applied Mechanics (2022), Fig. 8(a), p. 6 ↗CC BY 4.0cropped to the panel; resized
ROSES galleryFirst in vitro experiment in water-filled transparent tubing at Catanzaro. Danieli et al., Applied Mechanics (2022), Fig. 7(a), p. 5 ↗CC BY 4.0cropped to the panel; resized
ROSES galleryCAD of the cart arm that holds the robot actuator. Danieli et al., Applied Mechanics (2022), Fig. 13, p. 9 ↗CC BY 4.0cropped to the panel; resized
Caranx TAVI robot galleryOperator teleoperating the TAVI robot with a wireless handheld from a shielded room. Smits et al., Frontiers in Robotics and AI (2025), Fig. 3, p. 6 ↗CC BY 4.0cropped to the panel; resized
Caranx TAVI robot galleryPhantom testbench with tracking camera, monitor and user input device. Smits et al., Frontiers in Robotics and AI (2025), Fig. 7(a), p. 14 ↗CC BY 4.0cropped to the panel; resized
Hamlyn driver galleryCatheter manipulator at a vascular phantom with flow pumps, camera and EM tracking. Chi et al., International Journal of Computer Assisted Radiology and Surgery (2018), Fig. 4, p. 5 ↗CC BY 4.0cropped to the panel; resized
CardioXplorer galleryRobot driving an ablation catheter into the AF cardiac phantom in the cath lab. Xu et al., Robotics (2024), Fig. 12(a), robot trial, p. 10 ↗CC BY 4.0cropped to the panel; resized
CardioXplorer galleryManufactured robot from above: rotation module on the linear module, with dimensions. Xu et al., Robotics (2024), Fig. 2(a), lower photo, p. 4 ↗CC BY 4.0cropped to the panel; resized
CardioXplorer gallerySide view of the manufactured robot holding a catheter handle, with dimensions. Xu et al., Robotics (2024), Fig. 2(a), upper photo, p. 4 ↗CC BY 4.0cropped to the panel; resized
CardioXplorer galleryCAD rendering of the linear, rotation and catheter-mount modules. Xu et al., Robotics (2024), Fig. 2(b), p. 4 ↗CC BY 4.0cropped to the panel; resized
CardioXplorer galleryCAD of the adaptive silicone gripper around a catheter knob. Xu et al., Robotics (2024), Fig. 3(b), p. 4 ↗CC BY 4.0cropped to the panel; resized
CardioXplorer galleryGamepad controller in the control room and responder robot at the catheterisation suite. Xu et al., Robotics (2024), Fig. 8, p. 7 ↗CC BY 4.0cropped to the panel; resized
CardioXplorer galleryThree actuation configurations with the resulting catheter tip articulation. Xu et al., Robotics (2024), Fig. 9, p. 7 ↗CC BY 4.0cropped to the panel; resized

How to cite

@misc{catheter_robot_atlas,
  title  = {Catheter Robot Atlas: an open catalogue of endovascular catheter and guidewire robots},
  author = {[maintainer names]},
  year   = {2026},
  url    = {[site address]},
  note   = {Accompanies: Endovascular Catheter and Guidewire Robots: A Hardware Atlas (in preparation)}
}