Catheter Robot Atlas

Documentation

Schema & API

Every robot is one record, validated against a JSON Schema. The compiled catalogue is a set of static JSON files: fetch them directly, no key, no rate limit.

Records

One YAML file per robot in records/robots/<id>.yaml, all with the same fields. Free-text fields keep the wording of the sources, with the source key and section for every number. N.R. means the sources read do not report it; an empty field means nobody has filled it yet.

For now the records are generated from the catalogue CSV that the review's search agents fill (the CSV is the source of truth); the fields marked derived (devices, rotation_mechanism, has_sim_model, read_level) are classified from the free text by tools/build_site.py. Check any record with python3 tools/validate_records.py.

Robot fields

Required fields: schema_version, id, name, full_name, group, family, category, first_year, devices, translation_mechanism, rotation_mechanism, highest_validation, sim2real, picture, sources, read_level, maintainers_own. Examples are from the LegoBot record.

FieldTypeReq.Definition and allowed valuesExample
schema_versionintegeryesVersion of this schema.1
idstringyes<shortname>_<firstauthor or company><year>, lower case; also the file name and the page URL (robots/<id>.html).legobot_gao2026
namestringyesShort display name used on cards.LegoBot
full_namestringyesFull name as the sources give it, with a short description.LegoBot
groupstringyesDeveloper: laboratory, university or company, with clinical partners where stated.NYU BIRO Lab (H. Su)
group_shortstringShort form of the developer for cards.NYU
familystringyesOne of four families used across the atlas.
commercial, academic, tip, magnetic
academic
categorystringyesFiner category of the search briefs; family groups these.
commercial, clinical-stage, academic, actuated-device, magnetic-navigation
academic
first_yearinteger | nullyesYear of the first publication or product of this robot line; null when not reported.2026
latest_yearinteger | nullYear of the latest version found.2026
versionsstringLineage of versions with their papers (oldest first).2026 modular 2-DOF module; 2-module (4-DOF) and 3-module (6-DOF) assemblies
target_anatomystringIntended procedure or vessel territory.neurovascular (diagnostic angiography, aspiration thrombectomy); coronary and peripheral s…
devicesarray of stringyesDevice types the robot drives (derived from devices_driven by keyword; the free text is authoritative).
guidewire, microcatheter, catheter, sheath, therapeutic-device, other, not-reported
["guidewire", "microcatheter", "catheter"]
devices_drivenstringWhich devices, sizes and how many at once, as the sources state.guidewire 0.014 in; 2.8 Fr/0.028 in microcatheter; 5 Fr angiographic catheter; 6 Fr aspira…
n_dofinteger | nullNumber of actuated degrees of freedom (the leading number of n_dof_detail); null when not stated as a number.6
n_dof_detailstringDegrees of freedom as the sources state them.2 per module; 4 (two modules) or 6 (three modules)
translation_mechanismstringyesHow the robot pushes and pulls the device.
friction-roller, clamp-relay, belt/track, linear-stage+clamp, magnetic, tendon/tip-actuation, other, not-reported
friction-roller
translation_detailstringTranslation mechanism in the sources' words.friction-roller
rotation_mechanismstringyesHow the robot twists the device about its own axis (derived from rotation_detail by keyword with reviewed exceptions while the CSV is the source of truth).
rotating-clamp, rotating-drive-unit, roller-rolling, handle-rotation, tendon-bending, magnetic-field, none, other, not-reported
rotating-clamp
rotation_detailstringRotation mechanism in the sources' words.clamped-wheel rotation: hollow-shaft direct-drive motor (0.9 N.m peak) turns the clamped i…
device_rangestringDevice sizes the drive accepts.0.33-3 mm (adjustable clamp)
footprint_mmstringSize of the bedside unit in mm as reported.345 x 249 x 115 (three modules, Fig. 6a); module 190 mm wide
mass_kgstringMass in kg as reported.N.R.
force_sensingstringForce or torque sensing: where, how, accuracy.motor side only (current, dual 17-bit encoders); no direct instrument sensing (stated limi…
haptics_leaderstringLeader (master) device and haptic feedback.none; Xbox gamepad teleoperation; haptic feedback not yet implemented
imaging_compatstringImaging the robot works with (fluoroscopy, MRI, ultrasound) and radiation-related design.N.R. (not tested)
sterilitystringSterile barrier, cassette or disposable concept.not validated (stated future work); preloaded replaceable modules; standard Luer lock / Y-…
highest_validationstringyesHighest level at which the robot was tested.
bench, phantom, ex-vivo, animal, human
phantom
validation_detailstringWhat was tested, how often, with whom.benchtop: 8 Fr catheter slip test; buckling-load test with 5 devices; silicone neurovascul…
key_numbersstringHeadline performance numbers with their sources.peak insertion force 5.3 N and torque 8.4 mN.m (8 Fr) vs requirement 4.5 N / 8 mN.m; buckl…
sim_modelstringPublished simulation model of this robot or its devices (simulator, paper), or 'none found'.none found
has_sim_modelbooleanDerived: sim_model names a model (does not start with none, no or N.R.).False
sim2realstringyesHas a controller or model trained in simulation run on this robot?
yes, partial, model-based, unclear, none-found
none-found
sim2real_detailstringThe study, its level and its numbers.none found
pictureobjectyesThe best picture of the robot found. Only pictures whose licence allows reuse (CC BY without NC/ND/SA, or the maintainers' own material) are published; the others are described and linked to their source.{"status": "cleared", "grade": "A", "kind": "photo", "source": "BIRO Lab, New York Univers…
  picture.statusstringyescleared = licence allows reuse and the picture is shown; not-cleared = a picture exists at the source; none = no picture found.
cleared, not-cleared, none
cleared
  picture.gradestringyesQuality of the best picture found.
A, B, C, none
A
  picture.kindstring | nullWhat the picture is.
photo, render, product-photo, clinical-photo, drawing
photo
  picture.sourcestringWhere the picture comes from: paper key and figure, or page URL.BIRO Lab, New York University (own photograph)
  picture.source_urlstring | nullLink to the picture's source (DOI, arXiv or web page).
  picture.licencestringLicence as stated by the source.lab own (BIRO Lab, New York University)
  picture.creditstringAttribution line shown under a cleared picture.Photo: BIRO Lab, New York University.
  picture.editsstringChanges made to the picture (cropping, erased labels); CC BY asks for these to be indicated.
  picture.filestring | nullWeb-size copy (long side 800 px) in pictures/; present only when status is cleared.pictures/legobot_gao2026.jpg
picturesarray of objectFurther pictures of the robot from its papers or its maker (the gallery on its page), best first. Like the main picture, only cleared pictures are published; the others are described and linked to their source.[{"id": "legobot_gao2026_01", "status": "cleared", "file": "pictures/extra/legobot_gao2026…
  pictures.idstringyes<robot_id>_<nn>; also the file name.legobot_gao2026_01
  pictures.statusstringyescleared = licence allows reuse (shown on the public site); not-cleared = linked only.
cleared, not-cleared
cleared
  pictures.filestring | nullWeb copy, long side 1200 px; only when cleared.pictures/extra/legobot_gao2026_01.jpg
  pictures.thumbstring | nullThumbnail, long side 360 px; only when cleared.pictures/thumbs/legobot_gao2026_01.jpg
  pictures.kindstringyesWhat the picture shows.
photo, render, in-use, close-up, leader, setup
in-use
  pictures.captionstringyesNeutral caption, 6-15 words.Three-module robot driving devices into a neurovascular phantom, gamepad and GUI
  pictures.source_keystringBibTeX key of the paper, or web:<site> for a company or press page.gao2026_legobot
  pictures.sourcestringAttribution: authors, venue (year), figure and page.Gao et al., IEEE/ASME Transactions on Mechatronics (2026), lab photo IMG_4635.jpg, unannot…
  pictures.source_urlstring | nullLink to the source (DOI, arXiv or page).https://doi.org/10.1109/TMECH.2026.3695773
  pictures.wherestringFigure and page in the source, or the image URL.lab photo IMG_4635.jpg, unannotated original of Fig. 2
  pictures.licencestringyesLicence as stated by the source.lab own (collaborator material)
sourcesarray of objectyesPapers and pages the record is built from, oldest first where known.[{"key": "gao2026_legobot", "doi": "10.1109/TMECH.2026.3695773", "url": null, "title": "Le…
  sources.keystringyesBibTeX key <firstauthor><year>_<word>.gao2026_legobot
  sources.doistring | nullDOI without the https://doi.org/ prefix.10.1109/TMECH.2026.3695773
  sources.urlstring | nullLink when there is no DOI.
  sources.titlestring | nullLegoBot: Modular, compact, device-agnostic robot for endovascular catheter and guidewire m…
  sources.yearinteger | null2026
  sources.venuestring | nullIEEE/ASME Transactions on Mechatronics
read_levelstringyesDeepest reading behind the record.
full, partial, abstract, web, secondary
full
read_level_detailstringWhich source was read at which level.full
notesstringAnything that does not fit the fields above.Table I (gao2026_legobot) compares with CorPath GRX, LIBERTY, Magellan, R-One, ICL, KAIST,…
maintainers_ownbooleanyesTrue for the robots built by the lab that maintains this catalogue (conflict of interest, stated once on the About page; not marked on the site).True
found_bystringWhich logged search added the record.
academic, commercial, actuated-tip, gap, contributor
academic

Controlled vocabularies

Generated from the JSON Schema at build time, so they always match what validation accepts. Record counts are for this build.

family

ValueLabelDefinitionRecords
commercialCommercial and clinical-stage systemsProducts and clinical-stage systems from companies, including commercial magnetic systems.33
academicAcademic bedside robotsResearch robots at the bedside that push and twist catheters and guidewires.62
tipActuated-tip devicesDevices whose own tip bends (tendons, shape-memory alloy, fluid, notched tubes), with or without a bedside drive.10
magneticMagnetic navigationAcademic systems that steer a magnetic device tip with an external field.21

translation_mechanism

ValueLabelDefinitionRecords
friction-rollerFriction rollersA pair of wheels pinches the device and turns to push it; unlimited stroke.29
clamp-relayClamp relayGrippers alternately clamp and move, hand over hand.12
belt/trackBelt pinchTwo belts or tracks squeeze the device.2
linear-stage+clampLinear stageOne clamp rides a carriage on a rail or lead screw; stroke = rail length.16
magneticMagneticThe tip is steered by an external field; a separate feeder may push.25
tendon/tip-actuationTip-actuatedThe device bends itself (tendons, SMA, fluid).10
otherOther drivesHybrid or other drive; see translation_detail.24
not-reportedNot reportedNot reported in the sources read.8

rotation_mechanism

ValueLabelDefinitionRecords
rotating-clampRotating clampA clamp, gripper, chuck or torque device holds the device and turns with it.19
rotating-drive-unitRotating drive unitThe whole roller pair, cassette or frame turns about the device axis.18
roller-rollingRolling between rollersRollers or pads move across each other and roll the device between them, like thumb and forefinger.6
handle-rotationHandle or knobMotors turn a catheter handle or its steering knobs.11
tendon-bendingTendon bending onlyNo shaft rotation; the tip bends by tendons.4
magnetic-fieldField directionNo shaft rotation; the tip direction follows an external field.25
noneNoneNo rotation degree of freedom, or rotation by hand.8
otherOtherActuated, but the mechanism fits none of the classes above or is described only as 'a motor'.18
not-reportedNot reportedNot reported in the sources read.17

highest_validation

ValueLabelDefinitionRecords
benchBenchDevice driven on the bench (in air, in a straight tube); accuracy tests.18
phantomPhantomVessel phantom (silicone, 3D-printed, glass).54
ex-vivoEx vivoExcised tissue or cadaver.3
animalAnimalIn vivo animal study.26
humanHumanFirst-in-human or clinical study.25

sim2real

ValueLabelDefinitionRecords
yesYesA controller or perception model trained in simulation ran on this robot.8
partialPartial (motor level)A simulation-trained part ran on the robot at motor level only, not for navigation.1
model-basedModel-based onlyCommands computed in a simulator or from a physical model ran on the robot; nothing was learned.4
unclearUnclearLearning or simulation is reported but where it was trained is not stated.1
none-foundNone foundNo simulation-trained controller found for this robot.112

devices

ValueLabelDefinitionRecords
guidewireGuidewireGuidewire or microwire (including a robot's own wire).73
microcatheterMicrocatheterMicrocatheter.15
catheterCatheterGuide, diagnostic, aspiration, ablation, imaging or steerable catheter.94
sheathSheathSheath or steerable sheath.21
therapeutic-deviceBalloon, stent or valveBalloon, stent, stent retriever, coil, clip or valve delivery system.25
otherOtherOwn untethered or soft robot, or an unspecified instrument.7
not-reportedNot reportedNot reported.1

read_level

ValueLabelDefinitionRecords
fullFull text read.100
partialParts of the full text read.8
abstractAbstract only.10
webCompany, press or project page.8
secondaryThrough another review or catalogue.0

found_by

ValueLabelDefinitionRecords
academicSearch of academic bedside robots.28
commercialSearch of commercial and clinical-stage systems.24
actuated-tipSearch of actuated-tip and magnetic devices.28
gapGap searches for robots the other searches missed.46
contributorAdded by a contributor through a pull request.0

category

ValueLabelDefinitionRecords
commercialOn the market.13
clinical-stageCompany system in or near clinical trials.14
academicUniversity or institute research robot.62
actuated-deviceA device that actuates its own tip.10
magnetic-navigationExternal-field steering system.27

picture.status

ValueDefinitionRecords
clearedLicence allows reuse with credit; shown on the public site.21
not-clearedA picture exists but its licence does not allow reuse; the site links to the source.105
noneNo picture found.0

picture.grade

ValueDefinitionRecords
AClean, sharp, whole robot; good printed 2 in wide.28
BUsable with one flaw (small, clutter at the edge, CAD only, partly hidden).49
CBest available is still annotated, tiny or partial.49
noneNo picture found.0

Example record

api/robots/legobot_gao2026.json, shown as YAML:

schema_version: 1
id: legobot_gao2026
name: LegoBot
full_name: LegoBot
group: NYU BIRO Lab (H. Su)
group_short: NYU
family: academic
category: academic
first_year: 2026
latest_year: 2026
versions: 2026 modular 2-DOF module; 2-module (4-DOF) and 3-module (6-DOF) assemblies
target_anatomy: neurovascular (diagnostic angiography, aspiration thrombectomy); coronary and peripheral stated
  as applicable
devices:
- guidewire
- microcatheter
- catheter
devices_driven: guidewire 0.014 in; 2.8 Fr/0.028 in microcatheter; 5 Fr angiographic catheter; 6 Fr aspiration catheter;
  8 Fr guide catheter (five off-the-shelf devices tested for buckling load)
n_dof: 6
n_dof_detail: 2 per module; 4 (two modules) or 6 (three modules)
translation_mechanism: friction-roller
translation_detail: friction-roller
rotation_mechanism: rotating-clamp
rotation_detail: 'clamped-wheel rotation: hollow-shaft direct-drive motor (0.9 N.m peak) turns the clamped instrument;
  module coupler adds a second torque input via bevel gears; decoupled from translation by command compensation'
device_range: 0.33-3 mm (adjustable clamp)
footprint_mm: 345 x 249 x 115 (three modules, Fig. 6a); module 190 mm wide
mass_kg: N.R.
force_sensing: motor side only (current, dual 17-bit encoders); no direct instrument sensing (stated limitation)
haptics_leader: none; Xbox gamepad teleoperation; haptic feedback not yet implemented
imaging_compat: N.R. (not tested)
sterility: not validated (stated future work); preloaded replaceable modules; standard Luer lock / Y-connector interfaces
highest_validation: phantom
validation_detail: 'benchtop: 8 Fr catheter slip test; buckling-load test with 5 devices; silicone neurovascular
  phantom (Type III arch): angiography with 2 modules and aspiration thrombectomy with 3 modules (clot aspirated);
  one demonstration each, repeat counts N.R.; one timed module exchange 1 min 50 s'
key_numbers: 'peak insertion force 5.3 N and torque 8.4 mN.m (8 Fr) vs requirement 4.5 N / 8 mN.m; buckling load
  0.1 N (0.014 in wire) to 4.3 N (8 Fr); coupler: 5 full microcatheter rotations vs ~180 deg without; 500 Hz command
  loop; 345x249x115 mm for 3 instruments vs 360x250x250 mm (2 instruments) of Kantu per Table I'
sim_model: none found
has_sim_model: false
sim2real: none-found
sim2real_detail: none found
picture:
  status: cleared
  grade: A
  kind: photo
  source: BIRO Lab, New York University (own photograph)
  source_url: null
  licence: lab own (BIRO Lab, New York University)
  credit: 'Photo: BIRO Lab, New York University.'
  edits: ''
  file: pictures/legobot_gao2026.jpg
pictures:
- id: legobot_gao2026_01
  status: cleared
  file: pictures/extra/legobot_gao2026_01.jpg
  thumb: pictures/thumbs/legobot_gao2026_01.jpg
  kind: in-use
  caption: Three-module robot driving devices into a neurovascular phantom, gamepad and GUI
  source_key: gao2026_legobot
  source: Gao et al., IEEE/ASME Transactions on Mechatronics (2026), lab photo IMG_4635.jpg, unannotated original
    of Fig. 2
  source_url: https://doi.org/10.1109/TMECH.2026.3695773
  where: lab photo IMG_4635.jpg, unannotated original of Fig. 2
  licence: lab own (collaborator material)
- id: legobot_gao2026_02
  status: cleared
  file: pictures/extra/legobot_gao2026_02.jpg
  thumb: pictures/thumbs/legobot_gao2026_02.jpg
  kind: close-up
  caption: Single guide-catheter module with catheter loaded, gear train visible through window
  source_key: gao2026_legobot
  source: Gao et al., IEEE/ASME Transactions on Mechatronics (2026), lab video IMG_4651.MOV still, t = 0.67 s
  source_url: https://doi.org/10.1109/TMECH.2026.3695773
  where: lab video IMG_4651.MOV still, t = 0.67 s
  licence: lab own (collaborator material)
- id: legobot_gao2026_03
  status: not-cleared
  file: null
  thumb: null
  kind: photo
  caption: Guide-catheter, microcatheter and guidewire modules chained with triaxial devices loaded
  source_key: gao2026_legobot
  source: Gao et al., IEEE/ASME Transactions on Mechatronics (2026), Fig. 6(b), p. 6
  source_url: https://doi.org/10.1109/TMECH.2026.3695773
  where: Fig. 6(b), p. 6
  licence: publisher copyright (IEEE)
- id: legobot_gao2026_04
  status: not-cleared
  file: null
  thumb: null
  kind: photo
  caption: Top view of the stacked three-module 6-DOF prototype with dimensions
  source_key: gao2026_legobot
  source: Gao et al., IEEE/ASME Transactions on Mechatronics (2026), Fig. 6(a), p. 6
  source_url: https://doi.org/10.1109/TMECH.2026.3695773
  where: Fig. 6(a), p. 6
  licence: publisher copyright (IEEE)
- id: legobot_gao2026_05
  status: not-cleared
  file: null
  thumb: null
  kind: in-use
  caption: Two-module configuration performing diagnostic angiography in a silicone phantom
  source_key: gao2026_legobot
  source: Gao et al., IEEE/ASME Transactions on Mechatronics (2026), Fig. 9(a), p. 8
  source_url: https://doi.org/10.1109/TMECH.2026.3695773
  where: Fig. 9(a), p. 8
  licence: publisher copyright (IEEE)
- id: legobot_gao2026_06
  status: not-cleared
  file: null
  thumb: null
  kind: render
  caption: 'Exploded CAD of guidewire and catheter modules: lid, housing, 2-DOF cassette'
  source_key: gao2026_legobot
  source: Gao et al., IEEE/ASME Transactions on Mechatronics (2026), Fig. 5(c), p. 5
  source_url: https://doi.org/10.1109/TMECH.2026.3695773
  where: Fig. 5(c), p. 5
  licence: publisher copyright (IEEE)
- id: legobot_gao2026_07
  status: not-cleared
  file: null
  thumb: null
  kind: close-up
  caption: Cutaway CAD of the adjustable friction-roller clamping mechanism
  source_key: gao2026_legobot
  source: Gao et al., IEEE/ASME Transactions on Mechatronics (2026), Fig. 4, p. 4
  source_url: https://doi.org/10.1109/TMECH.2026.3695773
  where: Fig. 4, p. 4
  licence: publisher copyright (IEEE)
- id: legobot_gao2026_08
  status: not-cleared
  file: null
  thumb: null
  kind: setup
  caption: Guide-catheter module on bench with load cell for insertion and torque tests
  source_key: gao2026_legobot
  source: Gao et al., IEEE/ASME Transactions on Mechatronics (2026), Fig. 8(a)-(b), p. 7
  source_url: https://doi.org/10.1109/TMECH.2026.3695773
  where: Fig. 8(a)-(b), p. 7
  licence: publisher copyright (IEEE)
sources:
- key: gao2026_legobot
  doi: 10.1109/TMECH.2026.3695773
  url: null
  title: 'LegoBot: Modular, compact, device-agnostic robot for endovascular catheter and guidewire manipulation
    in stroke thrombectomy'
  year: 2026
  venue: IEEE/ASME Transactions on Mechatronics
read_level: full
read_level_detail: full
notes: Table I (gao2026_legobot) compares with CorPath GRX, LIBERTY, Magellan, R-One, ICL, KAIST, BIT and Kantu.
  Table I lists Kantu at 360x250x250 mm; the Kantu abstract says 250x350x250 mm.
maintainers_own: true
found_by: academic

Files and API

Static files next to the pages; all paths are relative to the site root.

PathContent
api/robots.jsonAll 126 robot records in one envelope: {name, generated, schema, metadata_licence, count, robots: [...]}.
api/robots/<id>.jsonOne robot record, e.g. api/robots/legobot_gao2026.json.
api/reviews.json34 hardware review records.
api/sim2real.json26 simulation-to-robot study records.
api/stats.jsonCounts by family, validation level, decade, push and twist mechanism, device, sim-to-real.
api/schema.jsonJSON Schema of a robot record (also review.schema.json, sim2real.schema.json).
robots.csvFlat table of all robot records: lists joined by '; ', picture.* as picture_* columns.

Fetch examples

Replace https://OWNER.github.io/REPO with the address where the site is published; locally, run python3 -m http.server 8000 in the site folder and use http://localhost:8000.

# everything
curl -s https://OWNER.github.io/REPO/api/robots.json -o robots.json
# one robot
curl -s https://OWNER.github.io/REPO/api/robots/legobot_gao2026.json
# robots tested in humans, with jq
curl -s https://OWNER.github.io/REPO/api/robots.json | jq -r '.robots[] | select(.highest_validation=="human") | .name'

schema.org markup

The home page carries a Dataset (name, description, creator, variables, JSON and CSV DataDownloads) for dataset search engines; the library page an ItemList of robot pages; each robot page a Thing whose subjectOf lists its papers as ScholarlyArticles with DOIs; the reviews page an ItemList of ScholarlyArticles. Absolute URLs are filled when the site is built with --base-url.

Review and study records

Hardware review (review.schema.json)

FieldTypeReq.DefinitionExample
schema_versionintegeryes1
keystringyesBibTeX key <firstauthor><year>_<word>.bonatti2014_robotic
yearintegeryesPublication year.2014
venuestringJournal or conference.Nat. Rev. Cardiol.
titlestringyesRobotic technology in cardiovascular medicine
doistring | nullyesDOI without the https://doi.org/ prefix.10.1038/nrcardio.2014.23
n_robotsstringHow many robots the review lists, and where.N.R. (abstract)
robot_picturesstringWhether the review shows pictures of the robots it lists.unknown (full text not read)
taxonomy_axesstringHow the review classifies robots.abstract: by field (interventional cardiology, electrophysiology, endovascular surgery, mi…
commercialstringCoverage of commercial systems (yes / no / which).unknown (full text not read)
academicstringCoverage of academic robots.unknown (full text not read)
actuated_tipstringCoverage of actuated-tip devices.unknown (full text not read)
magneticstringCoverage of magnetic navigation.unknown (full text not read)
simulationstringCoverage of simulation.unknown (full text not read)
sim2realstringCoverage of simulation-to-robot transfer.unknown (full text not read)
pagesinteger | string | nullPage count.10 (11(5):266-275)
n_refsinteger | string | nullNumber of references.54 (Crossref)
citationsinteger | string | nullCitation count when the review was read (source: OpenCitations or publisher page).86 (COCI, V1 2026-11-07)
read_levelstringHow the review was read.abstract (Europe PMC, PMID 24663088, R4A 2026-11-07)

Simulation-to-robot study (sim2real.schema.json)

FieldTypeReq.DefinitionExample
schema_versionintegeryes1
keystringyesBibTeX key of the study.behr2019_deep
yearintegeryes2019
venuestringCurr. Dir. Biomed. Eng. 5(1)
titlestring | nullyesPaper title from the bibliography; null when not in it.Deep Reinforcement Learning for the Navigation of Neurovascular Catheters
doistring | null10.1515/cdbme-2019-0002
urlstring | null
robot_idstring | nullThe robot record this study ran on, when the robot is in the catalogue.fraunhofer_karstensen2022
robot_usedstringThe physical robot as the paper describes it.Fraunhofer IPA experimental robotic manipulator for the two DOF of a guidewire: maximum li…
simulatorstringSOFA + BeamAdapter; rigid vessel walls, wall-guidewire friction 0.1, empty lumen (no dynam…
trainedstringWhat was trained (policy, perception model) and how.policy (DDPG, with HER and human demonstrations as options, OpenAI Baselines; DQN with dou…
observationstringabsolute guidewire tip coordinates, the target and the manipulator rotation (Sec. 2.1); on…
action_spacestringDDPG: continuous translation and rotation; DQN: discrete, 8 combinations of the two DOF (S…
gap_closingstringWhat the study did to close the simulation-to-robot gap.none described; 'The simulation does not yet include noise and latency' (Sec. 3)
real_setupstringWhere it ran on hardware (phantom, animal) and how often.idealised PMMA phantom, constant 10 mm vessel diameter, a bifurcation followed by a bi- an…
sim_successstringSuccess in simulation as reported.DDPG + HER 89.6% (sparse reward), DQN + Rainbow 86.5% (dense reward), average success rate…
real_successstringSuccess on the robot as reported.7/10 (the trained DDPG model on the test bench) (Sec. 3)
gap_measurestring89.6% -> 70% (7/10), reading the transferred 'trained DDPG model' as the DDPG + HER of the…
code_publicstringno
read_levelstringfull
notesstringPrimary read 2026-11-08: not simulation-only. The two reviews did not disagree: Robertshaw…