 "name": "Catheter Robot Atlas",
 "generated": "2026-11-11",
 "schema": "schema.json",
 "metadata_licence": "to be decided by the maintainers (CC0-1.0 or CC-BY-4.0)",
 "pictures": "Each picture keeps its owner's licence (see picture.licence); only cleared pictures are published.",
 "count": 126,
 "robots": [
  {
   "schema_version": 1,
   "id": "bit_rvirci_bao2022",
   "name": "RVIR-CI / RobEnt",
   "full_name": "RVIR-CI / RobEnt: BIT remote-controlled vascular interventional robot (catheter and guidewire cooperating on one rail; called RobEnt in the Tiantan clinical papers), with multilevel operation strategy",
   "group": "Beijing Institute of Technology (Shuxiang Guo, Nan Xiao) with Kagawa University; clinical partners Beijing Neurosurgical Institute / Beijing Tiantan Hospital (Youxiang Li, Yuhua Jiang, Keyun Liu)",
   "group_short": "BIT / Tiantan",
   "family": "commercial",
   "category": "clinical-stage",
   "first_year": 2012,
   "latest_year": 2022,
   "versions": "Kagawa remote catheter systems incl. remote angiography on a dog Kagawa-Beijing (chen2023_operating, secondary, ~2012) -> guo2016_design (MR-fluid force-feedback catheter system) -> bao2018_cooperation (RVIR-CI: catheter AND guidewire, 780 mm range) -> yang2019_vascular (fuzzy control, in vivo animal) -> bao2022_multilevel (three force zones, two haptic devices); isomorphic leader yang2022_isomorphic (full: real catheter and guidewire as handles on belt-coupled encoder platforms with linear-force and torque feedback, built after surgeons' feedback from in vivo experiments; Sec. 2-3); in-human operation evaluation bao2018_operation (Biomed. Microdevices 20:34, doi:10.1007/s10544-018-0277-5, title via Crossref, cited as ref. 13 of yang2022). Later BIT-Abrobo reciprocating robot (cao2024_reciprocating) became PANVIS-A: A4 scope, not catalogued here.; string-driven multi-slider slave with an optical-mouse master and kinetics + ADRC control (zhou2022_kinetics; its Sec. 2.2 says the slave was evaluated in bao2018_cooperation); RobEnt, the Tiantan team's name for the robot: first patient (jiang2018_initial, 2018) and ten pigs with micro-devices, a disposable waterproof cover and a sheath sleeve (liu2021_animal, 2021); 2011-15: J. Guo / N. Xiao (Kagawa-BIT) robotic catheter system with real-time force feedback: load cell + fibre-optic sensor (Guo 2011, 2012 ROBIO), Xiao 2012, push-force feedback with a mock-handle leader (Xiao 2015 ICIA) (Belikov 2024 Fig. 6 XI) (belikov2024_evolution; chen2023_operating; li2024_design); 2015: Jia / S. Guo (BIT) interventional surgical robot with force feedback, spur-gear rotation and torque-controlled gripper (Jia 2015 ROBIO; follow-ups Guo 2016, Wang 2018, Guo 2018) (Belikov 2024 Fig. 5 JI) (belikov2024_evolution; chen2023_operating); 2016: Bao / S. Guo guidewire navigation robot with fuzzy-PID force control (Bao 2016 ICMA; Guo 2016 ICMA) (Konda 2025 Table 2 row 13) (konda2025_robotically); 2018-20: Y. Zhao / S. Guo slave with on-line acquisition of the operating force by torque measurement (Zhao 2018 Biomed. Microdevices; 2019; 2020) (Belikov 2024 Fig. 6 ZH1) (belikov2024_evolution; chen2023_operating); 2022-24: C. Lyu / S. Guo robot with a flexible tactile-sensing gripper (FTG; lasso-style grip, force estimated from finger bending; Lyu 2023 RA-L) (Alekseeva 2025 Table 9 row 4, Figs. 10k, 14d) (alekseeva2025_design; li2024_design); 2020: N. Xiao (BIT) balloon-catheter delivery module with two geared conveyor belts on the lab's direct-push catheter/guidewire robot with joystick handles, bench (Yuan 2020 ICMA; host robot and operation logic Wang 2020 ICMA) (Alekseeva 2025 Table 4 row 4, Fig. 13b) (yuan2020_design; wang2020_reciprocating; alekseeva2025_design); 2018: S. Guo / N. Xiao (BIT) real-time master-slave (RTMS) system with closed-loop force feedback and a master handle that measures the surgeon's force (Guo 2018 Biomed. Microdevices 20, doi:10.1007/s10544-018-0278-4; Chen 2023 calls its guidewire mechanism heavy) (guo2018_realtime; chen2023_operating); 2019 and 2022: N. Xiao (BIT) sterile-side drive parts: bevel-gear catheter rotation structure for the guidewire operator (K. Wang 2019 ICMA) and a guidewire rotation-and-delivery transmission that limits slip (M. Cheng 2022 ICMA), both bench-tested for accuracy; Belikov codes the 2022 paper CHEs (wang2019_novel; cheng2022_novel; belikov2024_evolution); 2022-24: Y. Yan / S. Guo (BIT) 3-DoF slave with clamping-bracket grippers (PG2 SEA gripper, TIM 2023), grasping-force passive safety method with Changhai Hospital (TIM 2023) and an SEA haptic leader (ICRA 2024), ex vivo phantom per Alekseeva (Alekseeva 2025 Table 8 row 3, Fig. 10h) (alekseeva2025_design; yan2023_seabased; yan2023_grasping; yan2024_novel); 2022: deep-learning guidewire-compliant control (GCCM) run on the BIT endovascular surgery robot platform, slave rebuilt after Y. Zhao 2020 and Bao 2019, Geomagic Touch X leader, acrylic phantom, five operators: operating force -44.0 %, time -24.6 % (Lyu 2022 Micromachines; Konda 2025 control row 32) (lyu2022_deeplearningbased; konda2025_robotically); 2023: Y. Yan / S. Guo (BIT) spring-based tendon-driven steerable catheter for the group's master-slave robot: 1.5 mm active section (support spring with a 20 mm stainless-steel spine, one tendon, silicone coating) on a PTFE-lined passive section; the tendon pulled by a Maxon motor through a rack and pinion, displacement from the motor encoder; bench only, active section bent against a printed circle grid (radii 22.5 to 6 mm), bending radius from tendon displacement with mean absolute error 0.109 mm (6.53 %) (Yan 2023 ICMA, Secs. II-A, III, Figs. 8-10; Alekseeva 2025 Table 15 row 3) (yan2023_novel; alekseeva2025_design); RobEnt: robot of endovascular treatment with force feedback and cooperating catheter and guidewire (built by Beijing Institute of Technology; clinical team Beijing Neurosurgical Institute / Tiantan Hospital); BIT string-driven vascular intervention surgical robotic system (ADRC control)",
   "target_anatomy": "neurovascular: cerebral angiography in a patient (bilateral carotid and vertebral arteries, jiang2018_initial); human body vessel model; pig aortic arch vessels ex vivo",
   "devices": [
    "guidewire",
    "microcatheter",
    "catheter"
   ],
   "devices_driven": "catheter (5 F tested) + guidewire (0.8 mm rod used in rotary test), driven simultaneously by two manipulators on one rail (bao2018 Sec. 4); first patient: 5 F 135-degree angiographic catheter (Cordis) and 0.035-in 150 cm hydrophilic guidewire (Terumo) (jiang2018_initial p. 2); 2021 animals: also Exel-14 microcatheter and 0.014-in micro-guidewire inside the 5 F catheter (liu2021_animal p. 2, 4)",
   "n_dof": 4,
   "n_dof_detail": "4 (linear + rotary for each of catheter manipulator and guidewire manipulator; bao2018 Table 1)",
   "translation_mechanism": "linear-stage+clamp",
   "translation_detail": "linear-stage+clamp",
   "rotation_mechanism": "rotating-clamp",
   "rotation_detail": "Rotating conical-clamp grasper in each manipulator; assistant grasping mechanisms 1-3 on the rail hold the device while the manipulator returns (bao2018 Figs. 10, 12)",
   "device_range": "5 F catheter; guidewire ~0.8 mm (steel-rod test stand); no stated range limits; RobEnt 2018: travel 0.9 m, linear speed up to 90 cm/s, rotation up to 420 deg/s (jiang2018_initial p. 4); 2021: push 1.2 m, < 5 cm/s, < 180 deg/s (liu2021_animal p. 5)",
   "footprint_mm": "rail travel 780 mm (bao2018 Sec. 4.1); overall size N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "Proximal axial force per manipulator by strain-gauge sensor behind a low-friction bearing transmission (static connection, to avoid the slip of friction wheels): max relative error 2.53 % (catheter) / 2.48 % (guidewire) vs ATI reference (bao2018 Sec. 5.1). Tip contact: 1.3 mm fibre-optic pressure sensor in a 5 F catheter, 0-0.2 N (guo2019_novel Sec. IV-B).; RobEnt papers: force feedback on the console handle, resistance and vessel contact shown on the console, sensor type N.R. (jiang2018_initial p. 4)",
   "haptics_leader": "Bao 2018/2022: two commercial haptic devices (Geomagic Touch X), one per device. Guo 2019: passive magnetorheological-fluid leader around a real 7 F input catheter. Yang 2022: isomorphic leader with real catheter and guidewire as handles. yang2022 detail: catheter and guidewire fixed on their own handle platforms, belt-coupled to encoder motors, with linear-force and torque feedback devices and eccentric force compensation (Sec. 3, Figs. 3-11).; first patient: console with two haptic handles outside the room (jiang2018_initial Fig. 1); zhou2022: optical-mouse master reading axial and circumferential displacement, force feedback N.R.",
   "imaging_compat": "X-ray DSA (Siemens Artis zee III in 2018, AXIOM Artis dBA in 2021); robot not connected to the DSA (jiang2018_initial p. 4, 9)",
   "sterility": "sterile membrane over the slave, sterilisation time < 1 h (jiang2018_initial p. 4, 6); 2021: disposable sterile waterproof transparent cover and a sleeve at the arterial sheath (liu2021_animal p. 6-7); conical clamp holds the device without damaging its surface (bao2018 Sec. 2.2)",
   "highest_validation": "human",
   "validation_detail": "Human: 1 patient (chosen from 5 inpatients with suspected intracranial aneurysm), robot-driven cerebral angiography of both carotid and both vertebral arteries, about 40 min, no complication on 7.0 T MRI at 48 h or at the 7-day follow-up; Beijing Tiantan Hospital, Beijing; local ethics committee approval, no registration stated (jiang2018_initial Secs. 2-4). yang2022 Sec. 2 also cites clinical trials with this robot (Bao et al. 2018, Biomed. Microdevices 20:34, bao2018_operation, not read; patient count N.R.). Animal: 10 Bama miniature pigs (15-20 kg), at least three vessels each (liu2021_animal); pig in vivo trial (yang2019_vascular); dog remote test Kagawa-Beijing via the review chen2023_operating. Phantom: human-body vessel model (bao2018), in vitro model and ex vivo pig aortic arch (bao2022), vascular model 10 of 10 runs to the left subclavian artery (yang2022 Sec. 4.3), 2-D paraffin-wax model (zhou2022 Sec. 4).",
   "key_numbers": "CM accuracy 0.11 +/- 0.023 mm and 1.43 +/- 0.30 deg; GM 0.12 +/- 0.024 mm and 1.43 +/- 0.28 deg (bao2018 Table 1); range 780 mm at 20 mm/s; max grip force/torque CM 20.2 N / 24.4 mN.m, GM 18.5 N / 21.6 mN.m; leader-follower mean displacement error 0.038-0.241 mm (bao2022 Sec. V); pig in vivo tracking mean 0.22 mm / 0.17 deg (chen2023_operating, secondary); jiang2018: procedure about 40 min, axial accuracy 0.2 mm, rotation 2 deg; liu2021: mean operation 38.8 min, catheter-guidewire switch 2.8 min, axial 0.1 mm, rotation 5 deg; zhou2022: maximum steady errors 0.45 mm and 6.67 deg with kinetics + ADRC",
   "sim_model": "Not of the robot. Kagawa/BIT virtual-reality catheter-operation training simulators model catheter-vessel interaction (guo2012_virtual JRM; wang2016_virtual IJMRCAS, abstract level); no robot-drive simulator found.",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "photo",
    "source": "yang2019_vascular Fig. 4(a) (slave prototype on the linear motion platform), MBEC 2019, doi:10.1007/s11517-019-02016-8",
    "source_url": "https://doi.org/10.1007/s11517-019-02016-8",
    "licence": "publisher copyright",
    "credit": "Yang et al., Medical &amp; Biological Engineering &amp; Computing (2019), Fig. 4(a). publisher copyright.",
    "edits": "native extract (2057x1090 embedded image); cropped to panel (a); two white callout arrows on the wall and a red highlight around the steel ruler erased (LaMa, machine lock); one arrow-tip fragment on the table covered with adjacent table pixels; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "bit_rvirci_bao2022_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Slave manipulator mounted beside the C-arm for the in vivo pig trial",
     "source_key": "yang2019_vascular",
     "source": "Yang et al., Medical &amp; Biological Engineering &amp; Computing (2019), Fig. 9(a), p. 9",
     "source_url": "https://doi.org/10.1007/s11517-019-02016-8",
     "where": "Fig. 9(a), p. 9",
     "licence": "publisher copyright"
    },
    {
     "id": "bit_rvirci_bao2022_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "Physical prototype: catheter and guidewire manipulators with three assistant graspers",
     "source_key": "bao2018_cooperation",
     "source": "Bao et al., Biomedical Microdevices (2018), Fig. 12, p. 10",
     "source_url": "https://doi.org/10.1007/s10544-018-0261-0",
     "where": "Fig. 12, p. 10",
     "licence": "publisher copyright"
    },
    {
     "id": "bit_rvirci_bao2022_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Control module of one manipulator with gears and wiring",
     "source_key": "yang2019_vascular",
     "source": "Yang et al., Medical &amp; Biological Engineering &amp; Computing (2019), Fig. 4(d), p. 4",
     "source_url": "https://doi.org/10.1007/s11517-019-02016-8",
     "where": "Fig. 4(d), p. 4",
     "licence": "publisher copyright"
    },
    {
     "id": "bit_rvirci_bao2022_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Disposable clamping module gripping the catheter or guidewire",
     "source_key": "yang2019_vascular",
     "source": "Yang et al., Medical &amp; Biological Engineering &amp; Computing (2019), Fig. 4(b), p. 4",
     "source_url": "https://doi.org/10.1007/s11517-019-02016-8",
     "where": "Fig. 4(b), p. 4",
     "licence": "publisher copyright"
    },
    {
     "id": "bit_rvirci_bao2022_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Catheter manipulator coupled to an ATI force sensor for grasp tests",
     "source_key": "bao2018_cooperation",
     "source": "Bao et al., Biomedical Microdevices (2018), Fig. 13, p. 10",
     "source_url": "https://doi.org/10.1007/s10544-018-0261-0",
     "where": "Fig. 13, p. 10",
     "licence": "publisher copyright"
    },
    {
     "id": "bit_rvirci_bao2022_06",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Master side: catheter and guidewire haptic devices at the console",
     "source_key": "bao2018_cooperation",
     "source": "Bao et al., Biomedical Microdevices (2018), Fig. 7, p. 7",
     "source_url": "https://doi.org/10.1007/s10544-018-0261-0",
     "where": "Fig. 7, p. 7",
     "licence": "publisher copyright"
    },
    {
     "id": "bit_rvirci_bao2022_07",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Virtual prototype of the whole RVIR-CI on its linear motion platform",
     "source_key": "bao2018_cooperation",
     "source": "Bao et al., Biomedical Microdevices (2018), Fig. 11, p. 9",
     "source_url": "https://doi.org/10.1007/s10544-018-0261-0",
     "where": "Fig. 11, p. 9",
     "licence": "publisher copyright"
    },
    {
     "id": "bit_rvirci_bao2022_08",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Cutaway of the adjustable gripping mechanism inside the catheter manipulator",
     "source_key": "bao2022_multilevel",
     "source": "Bao et al., IEEE Transactions on Robotics (2022), Fig. 6(a), p. 5",
     "source_url": "https://doi.org/10.1109/tro.2022.3140887",
     "where": "Fig. 6(a), p. 5",
     "licence": "publisher copyright"
    },
    {
     "id": "bit_rvirci_bao2022_09",
     "status": "cleared",
     "file": "pictures/extra/bit_rvirci_bao2022_09.jpg",
     "thumb": "pictures/thumbs/bit_rvirci_bao2022_09.jpg",
     "kind": "in-use",
     "caption": "Draped slave on the angiography table during the first-patient angiography (RobEnt)",
     "source_key": "jiang2018_initial",
     "source": "Jiang et al., Applied Bionics and Biomechanics (2018), Fig. 3, PMC5926525 (former main picture of robent_jiang2018, patient area cropped)",
     "source_url": "https://doi.org/10.1155/2018/9735979",
     "where": "Fig. 3, PMC5926525 (former main picture of robent_jiang2018, patient area cropped)",
     "licence": "CC BY (Creative Commons Attribution License, version not stated in the article XML)"
    },
    {
     "id": "bit_rvirci_bao2022_10",
     "status": "cleared",
     "file": "pictures/extra/bit_rvirci_bao2022_10.jpg",
     "thumb": "pictures/thumbs/bit_rvirci_bao2022_10.jpg",
     "kind": "setup",
     "caption": "Master console with two haptic devices and the slave on the angiography table (RobEnt)",
     "source_key": "jiang2018_initial",
     "source": "Jiang et al., Applied Bionics and Biomechanics (2018), Fig. 1, PMC5926525",
     "source_url": "https://doi.org/10.1155/2018/9735979",
     "where": "Fig. 1, PMC5926525",
     "licence": "CC BY (Creative Commons Attribution License)"
    },
    {
     "id": "bit_rvirci_bao2022_11",
     "status": "cleared",
     "file": "pictures/extra/bit_rvirci_bao2022_11.jpg",
     "thumb": "pictures/thumbs/bit_rvirci_bao2022_11.jpg",
     "kind": "close-up",
     "caption": "Slave grippers holding catheter and guidewire under the sterile drape (RobEnt)",
     "source_key": "jiang2018_initial",
     "source": "Jiang et al., Applied Bionics and Biomechanics (2018), Fig. 2, PMC5926525",
     "source_url": "https://doi.org/10.1155/2018/9735979",
     "where": "Fig. 2, PMC5926525",
     "licence": "CC BY (Creative Commons Attribution License)"
    },
    {
     "id": "bit_rvirci_bao2022_12",
     "status": "cleared",
     "file": "pictures/extra/bit_rvirci_bao2022_12.jpg",
     "thumb": "pictures/thumbs/bit_rvirci_bao2022_12.jpg",
     "kind": "in-use",
     "caption": "Physician at the draped slave and operator at the master console during the first patient (RobEnt)",
     "source_key": "jiang2018_initial",
     "source": "Jiang et al., Applied Bionics and Biomechanics (2018), Fig. 4(a), left photos, p. 4",
     "source_url": "https://doi.org/10.1155/2018/9735979",
     "where": "Fig. 4(a), left photos, p. 4",
     "licence": "CC BY (Creative Commons Attribution License, version not stated)"
    },
    {
     "id": "bit_rvirci_bao2022_13",
     "status": "cleared",
     "file": "pictures/extra/bit_rvirci_bao2022_13.jpg",
     "thumb": "pictures/thumbs/bit_rvirci_bao2022_13.jpg",
     "kind": "in-use",
     "caption": "Physician beside the draped slave during the first-in-human angiography (RobEnt)",
     "source_key": "jiang2018_initial",
     "source": "Jiang et al., Applied Bionics and Biomechanics (2018), Fig. 5, p. 4",
     "source_url": "https://doi.org/10.1155/2018/9735979",
     "where": "Fig. 5, p. 4",
     "licence": "CC BY (Creative Commons Attribution License, version not stated)"
    },
    {
     "id": "bit_rvirci_bao2022_14",
     "status": "cleared",
     "file": "pictures/extra/bit_rvirci_bao2022_14.jpg",
     "thumb": "pictures/thumbs/bit_rvirci_bao2022_14.jpg",
     "kind": "photo",
     "caption": "Slave manipulator arm on the angiography table, draped, with the console screens behind (RobEnt)",
     "source_key": "liu2021_animal",
     "source": "Liu et al., Applied Bionics and Biomechanics (2021), Fig. 1, p. 4 (three image tiles, page region rendered at 300 dpi)",
     "source_url": "https://doi.org/10.1155/2021/8836268",
     "where": "Fig. 1, p. 4 (three image tiles, page region rendered at 300 dpi)",
     "licence": "CC BY (Creative Commons Attribution License, version not stated)"
    },
    {
     "id": "bit_rvirci_bao2022_15",
     "status": "cleared",
     "file": "pictures/extra/bit_rvirci_bao2022_15.jpg",
     "thumb": "pictures/thumbs/bit_rvirci_bao2022_15.jpg",
     "kind": "close-up",
     "caption": "Gear grippers of the slave arm holding the guidewire under the drape (RobEnt)",
     "source_key": "liu2021_animal",
     "source": "Liu et al., Applied Bionics and Biomechanics (2021), Fig. 2, p. 4",
     "source_url": "https://doi.org/10.1155/2021/8836268",
     "where": "Fig. 2, p. 4",
     "licence": "CC BY (Creative Commons Attribution License, version not stated)"
    },
    {
     "id": "bit_rvirci_bao2022_16",
     "status": "cleared",
     "file": "pictures/extra/bit_rvirci_bao2022_16.jpg",
     "thumb": "pictures/thumbs/bit_rvirci_bao2022_16.jpg",
     "kind": "close-up",
     "caption": "Joint between the slave arm and the femoral sheath of the pig (RobEnt)",
     "source_key": "liu2021_animal",
     "source": "Liu et al., Applied Bionics and Biomechanics (2021), Fig. 4, p. 4",
     "source_url": "https://doi.org/10.1155/2021/8836268",
     "where": "Fig. 4, p. 4",
     "licence": "CC BY (Creative Commons Attribution License, version not stated)"
    },
    {
     "id": "bit_rvirci_bao2022_17",
     "status": "cleared",
     "file": "pictures/extra/bit_rvirci_bao2022_17.jpg",
     "thumb": "pictures/thumbs/bit_rvirci_bao2022_17.jpg",
     "kind": "in-use",
     "caption": "Bama miniature pig on the table with the slave arm and the team (RobEnt)",
     "source_key": "liu2021_animal",
     "source": "Liu et al., Applied Bionics and Biomechanics (2021), Fig. 3, p. 4 (two image tiles, page region rendered at 300 dpi)",
     "source_url": "https://doi.org/10.1155/2021/8836268",
     "where": "Fig. 3, p. 4 (two image tiles, page region rendered at 300 dpi)",
     "licence": "CC BY (Creative Commons Attribution License, version not stated)"
    },
    {
     "id": "bit_rvirci_bao2022_18",
     "status": "cleared",
     "file": "pictures/extra/bit_rvirci_bao2022_18.jpg",
     "thumb": "pictures/thumbs/bit_rvirci_bao2022_18.jpg",
     "kind": "render",
     "caption": "Slave manipulator of the string-driven version: driver modules and clamps on one rail",
     "source_key": "zhou2022_kinetics",
     "source": "Zhou et al., Micromachines (2022), Fig. 4 (MDPI HTML figure g004; former main picture of bit_stringdriven_zhou2022, labels removed)",
     "source_url": "https://doi.org/10.3390/mi13050770",
     "where": "Fig. 4 (MDPI HTML figure g004; former main picture of bit_stringdriven_zhou2022, labels removed)",
     "licence": "CC BY 4.0"
    },
    {
     "id": "bit_rvirci_bao2022_19",
     "status": "cleared",
     "file": "pictures/extra/bit_rvirci_bao2022_19.jpg",
     "thumb": "pictures/thumbs/bit_rvirci_bao2022_19.jpg",
     "kind": "setup",
     "caption": "Slave clamps and driver modules, master manipulator and vascular model (string-driven version)",
     "source_key": "zhou2022_kinetics",
     "source": "Zhou et al., Micromachines (2022), Fig. 8 (MDPI HTML figure g008)",
     "source_url": "https://doi.org/10.3390/mi13050770",
     "where": "Fig. 8 (MDPI HTML figure g008)",
     "licence": "CC BY 4.0"
    },
    {
     "id": "bit_rvirci_bao2022_20",
     "status": "cleared",
     "file": "pictures/extra/bit_rvirci_bao2022_20.jpg",
     "thumb": "pictures/thumbs/bit_rvirci_bao2022_20.jpg",
     "kind": "leader",
     "caption": "Master manipulator CAD with force-feedback assemblies and its circuit board (string-driven version)",
     "source_key": "zhou2022_kinetics",
     "source": "Zhou et al., Micromachines (2022), Fig. 3 (MDPI HTML figure g003)",
     "source_url": "https://doi.org/10.3390/mi13050770",
     "where": "Fig. 3 (MDPI HTML figure g003)",
     "licence": "CC BY 4.0"
    },
    {
     "id": "bit_rvirci_bao2022_21",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "Yuan 2020 balloon-catheter module",
     "source_key": "yuan2020_design",
     "source": "Yuan et al., 2020 IEEE International Conference on Mechatronics and Automation (ICMA) (2020), yuan2020_design Fig. 8 photo of the balloon-catheter delivery device, p. 4",
     "source_url": "https://doi.org/10.1109/icma49215.2020.9233595",
     "where": "yuan2020_design Fig. 8 photo of the balloon-catheter delivery device, p. 4",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "bit_rvirci_bao2022_22",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Yuan 2020 balloon-catheter module: CAD of the three modules: conveyors, drive unit and support arm",
     "source_key": "yuan2020_design",
     "source": "Yuan et al., 2020 IEEE International Conference on Mechatronics and Automation (ICMA) (2020), Fig. 3, p. 3",
     "source_url": "https://doi.org/10.1109/icma49215.2020.9233595",
     "where": "Fig. 3, p. 3",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "bit_rvirci_bao2022_23",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Yuan 2020 balloon-catheter module: Conveyor module with pressure and belt-tensioning devices (CAD)",
     "source_key": "yuan2020_design",
     "source": "Yuan et al., 2020 IEEE International Conference on Mechatronics and Automation (ICMA) (2020), Fig. 5, p. 3",
     "source_url": "https://doi.org/10.1109/icma49215.2020.9233595",
     "where": "Fig. 5, p. 3",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "bit_rvirci_bao2022_24",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Yuan 2020 balloon-catheter module: Render of the host direct-push catheter and guidewire robot",
     "source_key": "wang2020_reciprocating",
     "source": "Wang et al., 2020 IEEE International Conference on Mechatronics and Automation (ICMA) (2020), Fig. 1, p. 2",
     "source_url": "https://doi.org/10.1109/ICMA49215.2020.9233703",
     "where": "Fig. 1, p. 2",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "bit_rvirci_bao2022_25",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Yuan 2020 balloon-catheter module: Laser rangefinder over the host robot rail during the tracking test",
     "source_key": "wang2020_reciprocating",
     "source": "Wang et al., 2020 IEEE International Conference on Mechatronics and Automation (ICMA) (2020), Fig. 9, p. 4",
     "source_url": "https://doi.org/10.1109/ICMA49215.2020.9233703",
     "where": "Fig. 9, p. 4",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "bit_rvirci_bao2022_26",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Yuan 2020 balloon-catheter module: Catheter and guidewire joystick handles of the host robot",
     "source_key": "wang2020_reciprocating",
     "source": "Wang et al., 2020 IEEE International Conference on Mechatronics and Automation (ICMA) (2020), Fig. 4, p. 2",
     "source_url": "https://doi.org/10.1109/ICMA49215.2020.9233703",
     "where": "Fig. 4, p. 2",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "bit_rvirci_bao2022_27",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Steerable-catheter bench: Maxon motor tendon drive, active section on a circle grid, camera",
     "source_key": "yan2023_novel",
     "source": "Yan et al., 2023 IEEE International Conference on Mechatronics and Automation (ICMA) (2023), Fig. 8(a), p. 770",
     "source_url": "https://doi.org/10.1109/icma57826.2023.10216269",
     "where": "Fig. 8(a), p. 770",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "bit_rvirci_bao2022_28",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Spring-based tendon-driven tip bent to radii from 22.5 to 6 mm",
     "source_key": "yan2023_novel",
     "source": "Yan et al., 2023 IEEE International Conference on Mechatronics and Automation (ICMA) (2023), Fig. 9, p. 771",
     "source_url": "https://doi.org/10.1109/icma57826.2023.10216269",
     "where": "Fig. 9, p. 771",
     "licence": "publisher copyright (IEEE)"
    }
   ],
   "sources": [
    {
     "key": "bao2018_cooperation",
     "doi": "10.1007/s10544-018-0261-0",
     "url": null,
     "title": "A cooperation of catheters and guidewires-based novel remote-controlled vascular interventional robot",
     "year": 2018,
     "venue": "Biomedical Microdevices"
    },
    {
     "key": "bao2022_multilevel",
     "doi": "10.1109/tro.2022.3140887",
     "url": null,
     "title": "Multilevel Operation Strategy of a Vascular Interventional Robot System for Surgical Safety in Teleoperation",
     "year": 2022,
     "venue": "IEEE Transactions on Robotics"
    },
    {
     "key": "guo2019_novel",
     "doi": "10.1109/tro.2019.2896763",
     "url": null,
     "title": "A Novel Robot-Assisted Endovascular Catheterization System With Haptic Force Feedback",
     "year": 2019,
     "venue": "IEEE Transactions on Robotics"
    },
    {
     "key": "guo2016_design",
     "doi": "10.1007/s10544-016-0100-0",
     "url": null,
     "title": "Design and characteristics evaluation of a novel teleoperated robotic catheterization system with force feedback for vascular interventional surgery",
     "year": 2016,
     "venue": "Biomedical Microdevices"
    },
    {
     "key": "yang2019_vascular",
     "doi": "10.1007/s11517-019-02016-8",
     "url": null,
     "title": "A vascular interventional surgical robot based on surgeon’s operating skills",
     "year": 2019,
     "venue": "Medical &amp; Biological Engineering &amp; Computing"
    },
    {
     "key": "yang2022_isomorphic",
     "doi": "10.3390/mi13010111",
     "url": null,
     "title": "An Isomorphic Interactive Device for the Interventional Surgical Robot after In Vivo Study",
     "year": 2022,
     "venue": "Micromachines"
    },
    {
     "key": "chen2023_operating",
     "doi": "10.1109/tmrb.2023.3272049",
     "url": null,
     "title": "The Catheter and Guidewire Operating Systems of Vascular Interventional Surgical Robots: A Systematic Review",
     "year": 2023,
     "venue": "IEEE Transactions on Medical Robotics and Bionics"
    },
    {
     "key": "guo2012_virtual",
     "doi": "10.20965/jrm.2012.p0649",
     "url": null,
     "title": "Virtual Reality Simulators Based on a Novel Robotic Catheter Operating System for Training in Minimally Invasive Surgery",
     "year": 2012,
     "venue": "Journal of Robotics and Mechatronics"
    },
    {
     "key": "wang2016_virtual",
     "doi": "10.1002/rcs.1769",
     "url": null,
     "title": "A virtual‐reality simulator and force sensation combined catheter operation training system and its preliminary evaluation",
     "year": 2016,
     "venue": "The International Journal of Medical Robotics and Computer Assisted Surgery"
    },
    {
     "key": "bao2018_operation",
     "doi": "10.1007/s10544-018-0277-5",
     "url": null,
     "title": "Operation evaluation in-human of a novel remote-controlled vascular interventional robot",
     "year": 2018,
     "venue": "Biomedical Microdevices"
    },
    {
     "key": "jiang2018_initial",
     "doi": "10.1155/2018/9735979",
     "url": null,
     "title": "Initial Clinical Trial of Robot of Endovascular Treatment with Force Feedback and Cooperating of Catheter and Guidewire",
     "year": 2018,
     "venue": "Applied Bionics and Biomechanics"
    },
    {
     "key": "liu2021_animal",
     "doi": "10.1155/2021/8836268",
     "url": null,
     "title": "Animal Experiment of a Novel Neurointerventional Surgical Robotic System with Master-Slave Mode",
     "year": 2021,
     "venue": "Applied Bionics and Biomechanics"
    },
    {
     "key": "zhou2022_kinetics",
     "doi": "10.3390/mi13050770",
     "url": null,
     "title": "Kinetics Analysis and ADRC-Based Controller for a String-Driven Vascular Intervention Surgical Robotic System",
     "year": 2022,
     "venue": "Micromachines"
    },
    {
     "key": "belikov2024_evolution",
     "doi": "10.1016/j.jestch.2024.101789",
     "url": null,
     "title": "Evolution and current state of robotic catheters for endovascular surgery: A comprehensive review",
     "year": 2024,
     "venue": "Engineering Science and Technology, an International Journal"
    },
    {
     "key": "li2024_design",
     "doi": "10.1109/tmrb.2024.3377374",
     "url": null,
     "title": "Robotic Systems Design in Endovascular Treatment",
     "year": 2024,
     "venue": "IEEE Transactions on Medical Robotics and Bionics"
    },
    {
     "key": "konda2025_robotically",
     "doi": "10.1126/scirobotics.adt7461",
     "url": null,
     "title": "Robotically steerable guidewires—Current trends and future directions",
     "year": 2025,
     "venue": "Science Robotics"
    },
    {
     "key": "alekseeva2025_design",
     "doi": "10.1002/rob.22480",
     "url": null,
     "title": "The Design of Endovascular Robots for Cardiac Interventions: A Survey",
     "year": 2024,
     "venue": "Journal of Field Robotics"
    },
    {
     "key": "yuan2020_design",
     "doi": "10.1109/icma49215.2020.9233595",
     "url": null,
     "title": "Design of a Novel Balloon Catheter Delivery Mechanism for the Vascular Interventional Robotic System",
     "year": 2020,
     "venue": "2020 IEEE International Conference on Mechatronics and Automation (ICMA)"
    },
    {
     "key": "wang2020_reciprocating",
     "doi": "10.1109/ICMA49215.2020.9233703",
     "url": null,
     "title": "Reciprocating Operation Method for Vascular Intervention Surgery Robot",
     "year": 2020,
     "venue": "2020 IEEE International Conference on Mechatronics and Automation (ICMA)"
    },
    {
     "key": "guo2018_realtime",
     "doi": "10.1007/s10544-018-0278-4",
     "url": null,
     "title": "Study on real-time force feedback for a master–slave interventional surgical robotic system",
     "year": 2018,
     "venue": "Biomedical Microdevices"
    },
    {
     "key": "wang2019_novel",
     "doi": "10.1109/icma.2019.8816446",
     "url": null,
     "title": "A Novel Catheter Rotation Structure for Aseptic Environment of Interventional Surgery Robot",
     "year": 2019,
     "venue": "2019 IEEE International Conference on Mechatronics and Automation (ICMA)"
    },
    {
     "key": "cheng2022_novel",
     "doi": "10.1109/icma54519.2022.9856010",
     "url": null,
     "title": "A Novel Guide Wire Rotation and Delivery Structure for Interventional Surgical Robot",
     "year": 2022,
     "venue": "2022 IEEE International Conference on Mechatronics and Automation (ICMA)"
    },
    {
     "key": "yan2023_seabased",
     "doi": "10.1109/tim.2022.3229695",
     "url": null,
     "title": "SEA-Based Humanoid Finger-Functional Parallel Gripper With Two Actuators: PG2 Gripper",
     "year": 2023,
     "venue": "IEEE Transactions on Instrumentation and Measurement"
    },
    {
     "key": "yan2023_grasping",
     "doi": "10.1109/tim.2023.3309365",
     "url": null,
     "title": "Grasping-Force-Based Passive Safety Method for a Vascular Interventional Surgery Robot System",
     "year": 2023,
     "venue": "IEEE Transactions on Instrumentation and Measurement"
    },
    {
     "key": "yan2024_novel",
     "doi": "10.1109/icra57147.2024.10611034",
     "url": null,
     "title": "A Novel SEA-based Haptic Interface for Robot-Assisted Vascular Interventional Surgery",
     "year": 2024,
     "venue": "2024 IEEE International Conference on Robotics and Automation (ICRA)"
    },
    {
     "key": "lyu2022_deeplearningbased",
     "doi": "10.3390/mi13122237",
     "url": null,
     "title": "A Deep-Learning-Based Guidewire Compliant Control Method for the Endovascular Surgery Robot",
     "year": 2022,
     "venue": "Micromachines"
    },
    {
     "key": "yan2023_novel",
     "doi": "10.1109/icma57826.2023.10216269",
     "url": null,
     "title": "A Novel Steerable Catheter for Vascular Interventional Surgery",
     "year": 2023,
     "venue": "2023 IEEE International Conference on Mechatronics and Automation (ICMA)"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (bao2018_cooperation; yang2022_isomorphic; zhou2022_kinetics; jiang2018_initial; liu2021_animal); partial (bao2022, guo2019); abstract (yang2019); title (bao2018_operation in-human); secondary via review (dog test); full (yan2023_novel, version line)",
   "notes": "Mechanism lesson stated in bao2018 Introduction: friction wheels slip, so proximal force is hard to measure; the group moved to conical-clamp graspers mounted on a force-sensing stage. ren2023_critical Table IV lists 'stroke 780 mm' for the BIT row, which matches bao2018 (the S8 evidence file could not find it in guo2019). | 2026-11-08 X3: highest_validation animal -> human on yang2022 Sec. 2 (clinical trials with this robot) + its ref. 13 (Bao 2018 in-human evaluation). robent_jiang2018 (X2 scope; Jiang, Liu, Li of Tiantan with BIT, first cerebral angiography, ABB 2018) is very likely the same BIT robot: coordinator to decide a merge. Bao 2018 in-human paper (Springer) not downloaded in this round | X4 2026-11-08: robent_jiang2018 and bit_stringdriven_zhou2022 merged into this row (data/merge_map.csv: same group, same one-rail slave, same room and slave in jiang2018 Fig. 1(b) and yang2019 Fig. 4). Category academic -> clinical-stage: a university robot that treated a first patient, filed like the Beihang, Hanyang and Asan robots (paper Secs. II, IV). | N4 2026-11-09: yan2023_novel read in full: the tendon is motor-driven (Sec. III, p. 770: 'actuated by a Maxon motor with a rack and pinion mechanism'), tested on the bench only (in air, against a circle grid; no vessel phantom in the paper, unlike Alekseeva's 'ex vivo phantom'); filed as a version line of this group's row, as Gao 2017 on sia_zhang2025; row cells unchanged; merged from robent_jiang2018 (A2); merged from bit_stringdriven_zhou2022 (A2)",
   "maintainers_own": false,
   "found_by": "academic"
  },
  {
   "schema_version": 1,
   "id": "kagawa_mrf_guo2019",
   "name": "RAECS / ECRS",
   "full_name": "Kagawa/BIT magnetorheological-fluid haptic master-slave catheter system (RAECS / ECRS)",
   "group": "Kagawa University and Beijing Institute of Technology (Shuxiang Guo; Yu Song, Xuanchun Yin, Linshuai Zhang, Xingyu Li); later Chengdu University of Information Technology",
   "group_short": "Kagawa / BIT",
   "family": "academic",
   "category": "academic",
   "first_year": 2016,
   "latest_year": 2025,
   "versions": "guo2016_design (MR-fluid leader, force-sensor array) -> yin2018_magnetorheological (2-DOF slave, force sensing unit) -> song2018_performance -> guo2019_novel (T-RO: MR leader around a real catheter, fibre-optic tip sensor, collision zones) -> zhang2021_magnetorheological (catheter+guidewire system) -> li2022_collaborative (ECRS: collaborative handles, hydrogel + solid MR fluid, tremor-reduction structure) -> zhang2025_innovative (MRF master interface); 2007: S. Guo (Kagawa) \"new catheter operating system\" (Guo, Kondo, Wang, Guo, Tamiya 2007, ICME; Rafii-Tari 2014 Table 4 row 2) (rafiitari2014_current); 2014-21: J. Guo / S. Guo grasper-type slave (Belikov GU2.1-2.3): 2014 grasper, 2019 wedge-block guidewire clamp (ICMA), 2020 fuzzy PID, 2021 pinion fixture (ICMA), Liao 2022 (Alekseeva 2025 Table 6 row 5, Fig. 10f) (alekseeva2025_design; belikov2024_evolution; chen2023_operating; li2024_design); 2006: Harbin Engineering University with S. Guo, master-slave catheter driving mechanism for intravascular neurosurgery, two stepping motors (disk gear rotation, gear-pair axial drive), Internet remote control, bench precision test of a 2 mm catheter with a laser displacement sensor (Feng 2006 ICMA) (Zhao 2022 Table 1 row 24; Li 2024 Fig. 5A) (feng2006_highly; zhao2022_remote; li2024_design)",
   "target_anatomy": "cerebrovascular / general (endovascular evaluator model)",
   "devices": [
    "guidewire",
    "catheter"
   ],
   "devices_driven": "guo2016: catheter on a slave whose insertion angle adjusts 0-45 deg (guo2016 Sec. 2.4); yin2018 and guo2019: one 5 F patient catheter (7 F input catheter at the leader); zhang2021: catheter or guidewire held by an electromagnetic adaptive collet (Sec. 3, Fig. 4); li2022: 5 Fr catheter and 260 cm J-type guidewire at once, catheter and guidewire manipulation units (CMU, GMU) (Sec. 2.2, 4.4)",
   "n_dof": 2,
   "n_dof_detail": "2 for the catheter (axial, radial; guo2016, yin2018, guo2019); li2022 CMU + GMU move catheter and guidewire separately (count N.R.)",
   "translation_mechanism": "clamp-relay",
   "translation_detail": "clamp-relay (guo2019: platform on two stepper motors, grasper A holds for insertion/retraction/rotation while grasper B holds the catheter during A's return; axial grip force 4 N, S8 reading of Sec. II-B)",
   "rotation_mechanism": "rotating-clamp",
   "rotation_detail": "Rotation of the holding grasper (radial DOF)",
   "device_range": "5 F catheter (guo2019)",
   "footprint_mm": "li2022 slave: 920 mm overall length, 400 mm CMU/GMU travel (Sec. 2.2); earlier versions N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "Load cell on the follower for proximal force; 1.3 mm fibre-optic pressure sensor in a 5 F catheter for tip contact force, working range 0-0.2 N (guo2019 Sec. IV-B); guo2016: load cell on the driven module behind grasper 1, plus a tip force-sensor array; zhang2021: load cell under the clamp; li2022: two TEAC TU-UJ load cells (+/-5 N) and two torque sensors for radial torque (Sec. 2.2)",
   "haptics_leader": "Passive MR-fluid haptic interface around the real input catheter; resistance up to ~0.5 N at 150 mT (0.4 N at 110 mT); three levels switched at tip forces 0.08, 0.10, 0.12 N (guo2019); ten operators noticed the step at 150 mT in 93 % of trials",
   "imaging_compat": "N.R.",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "In vitro only: guo2016 tracking and force-feedback benches with a vascular model; yin2018 ten novice volunteers drove a 5 Fr catheter through a rigid cerebral model into a wide-neck aneurysm; guo2019 ten operators in the EVE model; zhang2021 ten non-medical subjects in the EVE model with collision cues; li2022 tracking tests and six trialists inserting a guidewire into the EVE model with and without haptics; zhang2025 volunteers reaching targets along a 15 cm vascular-model path (Sec. 4 of each)",
   "key_numbers": "guo2019: axial positioning error 1.23 +/- 0.07 mm, rotation 1.57 +/- 0.07 deg; li2022: mean translation tracking error 0.94 mm, rotation 0.89 deg (abstract); MR resistance 0.16-0.5 N across 30-150 mT; guo2016: axial tracking error < 2 mm; zhang2021: axial transmission error < 1 mm (10 runs), 5 Fr catheter driven at 3.5 mm/s in the force test; li2022: CMU/GMU stepping motors 0.36 deg resolution",
   "sim_model": "VR catheter-operation simulators from the same group (guo2012_virtual; wang2016_virtual); no physics model of the follower found",
   "has_sim_model": true,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "A",
    "kind": "photo",
    "source": "guo2019_novel Fig. 3 (catheter manipulator photo: grasper A, load cell, grasper B on ball-screw stage), T-RO 2019, doi:10.1109/TRO.2019.2896763",
    "source_url": "https://doi.org/10.1109/TRO.2019.2896763",
    "licence": "publisher copyright",
    "credit": "Guo et al., IEEE Transactions on Robotics (2019), Fig. 3. publisher copyright.",
    "edits": "native extract (2073x1373); 4 text labels and 4 straight leader arrows on the wall, a curved double arrow above grasper A, and a double-headed motion arrow over the linear-stage base plate erased (LaMa + OpenCV Telea for arrow tips, local chroma correction of fill tint); cropped; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "kagawa_mrf_guo2019_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Local master haptic interface and remote catheter manipulator with vascular model",
     "source_key": "guo2019_novel",
     "source": "Guo et al., IEEE Transactions on Robotics (2019), Fig. 14, p. 7",
     "source_url": "https://doi.org/10.1109/tro.2019.2896763",
     "where": "Fig. 14, p. 7",
     "licence": "publisher copyright"
    },
    {
     "id": "kagawa_mrf_guo2019_02",
     "status": "cleared",
     "file": "pictures/extra/kagawa_mrf_guo2019_02.jpg",
     "thumb": "pictures/thumbs/kagawa_mrf_guo2019_02.jpg",
     "kind": "photo",
     "caption": "ECRS slave with catheter and guidewire manipulation units on a slide rail",
     "source_key": "li2022_collaborative",
     "source": "Li et al., Micromachines (2022), Fig. 3 (MDPI HTML figure g003)",
     "source_url": "https://doi.org/10.3390/mi13040505",
     "where": "Fig. 3 (MDPI HTML figure g003)",
     "licence": "CC BY 4.0"
    },
    {
     "id": "kagawa_mrf_guo2019_03",
     "status": "cleared",
     "file": "pictures/extra/kagawa_mrf_guo2019_03.jpg",
     "thumb": "pictures/thumbs/kagawa_mrf_guo2019_03.jpg",
     "kind": "leader",
     "caption": "MR-fluid haptic master: magnetic field generator around the input catheter",
     "source_key": "yin2018_magnetorheological",
     "source": "Yin et al., Micromachines (2018), Fig. 11 (MDPI HTML figure g011)",
     "source_url": "https://doi.org/10.3390/mi9090465",
     "where": "Fig. 11 (MDPI HTML figure g011)",
     "licence": "CC BY 4.0"
    },
    {
     "id": "kagawa_mrf_guo2019_04",
     "status": "cleared",
     "file": "pictures/extra/kagawa_mrf_guo2019_04.jpg",
     "thumb": "pictures/thumbs/kagawa_mrf_guo2019_04.jpg",
     "kind": "leader",
     "caption": "MR-fluid master with encoders for translation and rotation of the catheter",
     "source_key": "zhang2021_magnetorheological",
     "source": "Zhang et al., Micromachines (2021), Fig. 3 (MDPI HTML figure g003)",
     "source_url": "https://doi.org/10.3390/mi12060640",
     "where": "Fig. 3 (MDPI HTML figure g003)",
     "licence": "CC BY 4.0"
    },
    {
     "id": "kagawa_mrf_guo2019_05",
     "status": "cleared",
     "file": "pictures/extra/kagawa_mrf_guo2019_05.jpg",
     "thumb": "pictures/thumbs/kagawa_mrf_guo2019_05.jpg",
     "kind": "setup",
     "caption": "Slave manipulator with load cell and sliding table for force calibration",
     "source_key": "zhang2021_magnetorheological",
     "source": "Zhang et al., Micromachines (2021), Fig. 13 (MDPI HTML figure g013)",
     "source_url": "https://doi.org/10.3390/mi12060640",
     "where": "Fig. 13 (MDPI HTML figure g013)",
     "licence": "CC BY 4.0"
    },
    {
     "id": "kagawa_mrf_guo2019_06",
     "status": "cleared",
     "file": "pictures/extra/kagawa_mrf_guo2019_06.jpg",
     "thumb": "pictures/thumbs/kagawa_mrf_guo2019_06.jpg",
     "kind": "in-use",
     "caption": "Slave manipulator robot driving devices into the EVE vascular model",
     "source_key": "li2022_collaborative",
     "source": "Li et al., Micromachines (2022), Fig. 15(b) (MDPI HTML figure g015)",
     "source_url": "https://doi.org/10.3390/mi13040505",
     "where": "Fig. 15(b) (MDPI HTML figure g015)",
     "licence": "CC BY 4.0"
    },
    {
     "id": "kagawa_mrf_guo2019_07",
     "status": "cleared",
     "file": "pictures/extra/kagawa_mrf_guo2019_07.jpg",
     "thumb": "pictures/thumbs/kagawa_mrf_guo2019_07.jpg",
     "kind": "setup",
     "caption": "MRF master interface and slave manipulator with force sensor on the bench",
     "source_key": "zhang2025_innovative",
     "source": "Zhang et al., Sensors (2025), Fig. 12 (MDPI HTML figure g012)",
     "source_url": "https://doi.org/10.3390/s25247450",
     "where": "Fig. 12 (MDPI HTML figure g012)",
     "licence": "CC BY 4.0"
    },
    {
     "id": "kagawa_mrf_guo2019_08",
     "status": "cleared",
     "file": "pictures/extra/kagawa_mrf_guo2019_08.jpg",
     "thumb": "pictures/thumbs/kagawa_mrf_guo2019_08.jpg",
     "kind": "render",
     "caption": "CAD of the ECRS slave with catheter and guidewire operating units",
     "source_key": "li2022_collaborative",
     "source": "Li et al., Micromachines (2022), Fig. 2 (MDPI HTML figure g002)",
     "source_url": "https://doi.org/10.3390/mi13040505",
     "where": "Fig. 2 (MDPI HTML figure g002)",
     "licence": "CC BY 4.0"
    }
   ],
   "sources": [
    {
     "key": "guo2019_novel",
     "doi": "10.1109/tro.2019.2896763",
     "url": null,
     "title": "A Novel Robot-Assisted Endovascular Catheterization System With Haptic Force Feedback",
     "year": 2019,
     "venue": "IEEE Transactions on Robotics"
    },
    {
     "key": "guo2016_design",
     "doi": "10.1007/s10544-016-0100-0",
     "url": null,
     "title": "Design and characteristics evaluation of a novel teleoperated robotic catheterization system with force feedback for vascular interventional surgery",
     "year": 2016,
     "venue": "Biomedical Microdevices"
    },
    {
     "key": "yin2018_magnetorheological",
     "doi": "10.3390/mi9090465",
     "url": null,
     "title": "Magnetorheological Fluids Actuated Haptic-Based Teleoperated Catheter Operating System",
     "year": 2018,
     "venue": "Micromachines"
    },
    {
     "key": "song2018_performance",
     "doi": "10.1007/s10544-018-0294-4",
     "url": null,
     "title": "Performance evaluation of a robot-assisted catheter operating system with haptic feedback",
     "year": 2018,
     "venue": "Biomedical Microdevices"
    },
    {
     "key": "zhang2021_magnetorheological",
     "doi": "10.3390/mi12060640",
     "url": null,
     "title": "A Magnetorheological Fluids-Based Robot-Assisted Catheter/Guidewire Surgery System for Endovascular Catheterization",
     "year": 2021,
     "venue": "Micromachines"
    },
    {
     "key": "li2022_collaborative",
     "doi": "10.3390/mi13040505",
     "url": null,
     "title": "An Endovascular Catheterization Robotic System Using Collaborative Operation with Magnetically Controlled Haptic Force Feedback",
     "year": 2022,
     "venue": "Micromachines"
    },
    {
     "key": "zhang2025_innovative",
     "doi": "10.3390/s25247450",
     "url": null,
     "title": "An Innovative Master Haptic Interface Employing Magnetorheological Fluids for Endovascular Catheterization",
     "year": 2025,
     "venue": "Sensors"
    },
    {
     "key": "guo2012_virtual",
     "doi": "10.20965/jrm.2012.p0649",
     "url": null,
     "title": "Virtual Reality Simulators Based on a Novel Robotic Catheter Operating System for Training in Minimally Invasive Surgery",
     "year": 2012,
     "venue": "Journal of Robotics and Mechatronics"
    },
    {
     "key": "wang2016_virtual",
     "doi": "10.1002/rcs.1769",
     "url": null,
     "title": "A virtual‐reality simulator and force sensation combined catheter operation training system and its preliminary evaluation",
     "year": 2016,
     "venue": "The International Journal of Medical Robotics and Computer Assisted Surgery"
    },
    {
     "key": "rafiitari2014_current",
     "doi": "10.1007/s10439-013-0946-8",
     "url": null,
     "title": "Current and Emerging Robot-Assisted Endovascular Catheterization Technologies: A Review",
     "year": 2014,
     "venue": "Annals of Biomedical Engineering"
    },
    {
     "key": "alekseeva2025_design",
     "doi": "10.1002/rob.22480",
     "url": null,
     "title": "The Design of Endovascular Robots for Cardiac Interventions: A Survey",
     "year": 2024,
     "venue": "Journal of Field Robotics"
    },
    {
     "key": "belikov2024_evolution",
     "doi": "10.1016/j.jestch.2024.101789",
     "url": null,
     "title": "Evolution and current state of robotic catheters for endovascular surgery: A comprehensive review",
     "year": 2024,
     "venue": "Engineering Science and Technology, an International Journal"
    },
    {
     "key": "chen2023_operating",
     "doi": "10.1109/tmrb.2023.3272049",
     "url": null,
     "title": "The Catheter and Guidewire Operating Systems of Vascular Interventional Surgical Robots: A Systematic Review",
     "year": 2023,
     "venue": "IEEE Transactions on Medical Robotics and Bionics"
    },
    {
     "key": "li2024_design",
     "doi": "10.1109/tmrb.2024.3377374",
     "url": null,
     "title": "Robotic Systems Design in Endovascular Treatment",
     "year": 2024,
     "venue": "IEEE Transactions on Medical Robotics and Bionics"
    },
    {
     "key": "feng2006_highly",
     "doi": "10.1109/icma.2006.257760",
     "url": null,
     "title": "Highly Precise Catheter Driving Mechanism for Intravascular Neurosurgery",
     "year": 2006,
     "venue": "2006 International Conference on Mechatronics and Automation"
    },
    {
     "key": "zhao2022_remote",
     "doi": "10.21037/qims-21-792",
     "url": null,
     "title": "Remote vascular interventional surgery robotics: a literature review",
     "year": 2022,
     "venue": "Quantitative Imaging in Medicine and Surgery"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (guo2019; guo2016_design, yin2018, zhang2021, li2022 and zhang2025 PDFs in lit/pdfs, 2026-11-08)",
   "notes": "Highest validation is bench/phantom in every paper found; the animal and dog experiments belong to the RVIR-CI lineage (bit_rvirci_bao2022). MDPI and PMC render URLs returned HTTP 403 for the wrapper, so 2018-2022 MDPI papers are abstract-level (manual-download list in the notes). | 2026-11-08 X3: five MDPI/Springer papers read in full; gallery already 8, nothing added. All tests stay in vitro, so validation stays phantom",
   "maintainers_own": false,
   "found_by": "academic"
  },
  {
   "schema_version": 1,
   "id": "southeast_jin2024",
   "name": "MR-fluid platform",
   "full_name": "Southeast University / Kagawa MR-fluid haptic robotic platform with force sensing and guidewire-catheter collaborative operation",
   "group": "Southeast University, State Key Laboratory of Digital Medical Engineering (Aiguo Song; Xiaoliang Jin) with Kagawa University (Shuxiang Guo); Zhuhai Hanglok Medical Technology co-author on the 2025 follow-up",
   "group_short": "Southeast U.",
   "family": "academic",
   "category": "academic",
   "first_year": 2023,
   "latest_year": 2024,
   "versions": "jin2024_novel (T-IM 2024, received Mar 2023) -> jin2025_natural (T-HMS 2025: leader device with haptic feedback; abstract not read)",
   "target_anatomy": "vessel model; endovascular evaluator (EVE) model at 120/80 mmHg",
   "devices": [
    "guidewire",
    "catheter"
   ],
   "devices_driven": "guidewire and catheter (guidewire unit GMU, catheter unit CMU)",
   "n_dof": null,
   "n_dof_detail": "N.R.",
   "translation_mechanism": "linear-stage+clamp",
   "translation_detail": "linear-stage+clamp",
   "rotation_mechanism": "rotating-clamp",
   "rotation_detail": "Synchronous-belt rotation of the grasper (pulley diameter 46.3 mm; belt also used for linear motion)",
   "device_range": "N.R.",
   "footprint_mm": "rail with ruler in Fig. 6 photo; size N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "Total proximal force by TEAC TU-UJ5N load cell (-5 to 5 N) on a lead screw behind the grasper (spring-loaded slider moves slightly under load); torque by torque sensor during rotation; load cell reads positive for guidewire insertion",
   "haptics_leader": "MR-fluid haptic leader: two coils (30 mm inner, 120 mm outer diameter, 1200 turns); haptic force rises with current over 0-0.6 A (about 0.4 to 2.1 N, read from the Fig. 5 plot)",
   "imaging_compat": "N.R.",
   "sterility": "N.R.; grasper contact blocks are rubber-faced and opened by hollow steppers",
   "highest_validation": "phantom",
   "validation_detail": "Vessel model and EVE endovascular evaluator; sample counts N.R. in the sections read",
   "key_numbers": "Load cell +/-5 N; stepper 0.36 deg resolution; haptic force 0.4-2.1 N for 0-0.6 A (plot reading)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "photo",
    "source": "jin2024_novel Fig. 6 (follower manipulator with CMU and GMU), T-IM 2024, doi:10.1109/TIM.2023.3338682",
    "source_url": "https://doi.org/10.1109/TIM.2023.3338682",
    "licence": "publisher copyright",
    "credit": "Jin et al., IEEE Transactions on Instrumentation and Measurement (2024), Fig. 6. publisher copyright.",
    "edits": "native extract (688x380, the largest copy in the PDF); red dashed unit boxes, 4 labels and 4 arrows removed (OpenCV Telea, colour and darkness masks on the wall and rail); 5 px frame cropped; not upscaled.",
    "file": null
   },
   "pictures": [
    {
     "id": "southeast_jin2024_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Follower manipulator delivering devices into the EVE model under a camera",
     "source_key": "jin2024_novel",
     "source": "Jin et al., IEEE Transactions on Instrumentation and Measurement (2024), Fig. 13, p. 6",
     "source_url": "https://doi.org/10.1109/tim.2023.3338682",
     "where": "Fig. 13, p. 6",
     "licence": "publisher copyright"
    },
    {
     "id": "southeast_jin2024_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "MR-fluid leader manipulator with catheter and guidewire control units",
     "source_key": "jin2024_novel",
     "source": "Jin et al., IEEE Transactions on Instrumentation and Measurement (2024), Fig. 3, p. 3",
     "source_url": "https://doi.org/10.1109/tim.2023.3338682",
     "where": "Fig. 3, p. 3",
     "licence": "publisher copyright"
    },
    {
     "id": "southeast_jin2024_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Linkage leader device coupled to an F/T sensor for testing",
     "source_key": "jin2025_natural",
     "source": "Jin et al., IEEE Transactions on Human-Machine Systems (2025), Fig. 7, p. 5",
     "source_url": "https://doi.org/10.1109/thms.2025.3591542",
     "where": "Fig. 7, p. 5",
     "licence": "publisher copyright"
    },
    {
     "id": "southeast_jin2024_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Leader device next to the follower manipulator and joystick",
     "source_key": "jin2025_natural",
     "source": "Jin et al., IEEE Transactions on Human-Machine Systems (2025), Fig. 12, p. 7",
     "source_url": "https://doi.org/10.1109/thms.2025.3591542",
     "where": "Fig. 12, p. 7",
     "licence": "publisher copyright"
    },
    {
     "id": "southeast_jin2024_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Grasper device with two sliding blocks driven by stepping motors",
     "source_key": "jin2024_novel",
     "source": "Jin et al., IEEE Transactions on Instrumentation and Measurement (2024), Fig. 7(a), p. 4",
     "source_url": "https://doi.org/10.1109/tim.2023.3338682",
     "where": "Fig. 7(a), p. 4",
     "licence": "publisher copyright"
    },
    {
     "id": "southeast_jin2024_06",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD of the leader device: linkage, encoders and DC motors",
     "source_key": "jin2025_natural",
     "source": "Jin et al., IEEE Transactions on Human-Machine Systems (2025), Fig. 3(a), p. 3",
     "source_url": "https://doi.org/10.1109/thms.2025.3591542",
     "where": "Fig. 3(a), p. 3",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "jin2024_novel",
     "doi": "10.1109/tim.2023.3338682",
     "url": null,
     "title": "A Novel Robotic Platform for Endovascular Surgery: Human–Robot Interaction Studies",
     "year": 2024,
     "venue": "IEEE Transactions on Instrumentation and Measurement"
    }
   ],
   "read_level": "partial",
   "read_level_detail": "partial (jin2024 text); abstract (jin2025)",
   "notes": "Same Kagawa lineage as kagawa_mrf_guo2019 but with a load cell mounted on the grasper slide for proximal force. | 2026-10-13 coordinator: jin2025_natural moved to hanglok_wang2024: its follower is the Hanglok MULLER unit (W4, P2) | 2026-10-13 Q2: latest_year 2025 -> 2024 after jin2025_natural moved to hanglok_wang2024",
   "maintainers_own": false,
   "found_by": "academic"
  },
  {
   "schema_version": 1,
   "id": "hanglok_wang2024",
   "name": "Hanglok-Tech VIR",
   "full_name": "Hanglok-Tech vascular interventional robot (distributed architecture with DSA vision-servoing co-pilot)",
   "group": "Hanglok-Tech Co. Ltd., with Southeast University, South China University of Technology, Macau University of Science and Technology, Guangzhou First People's Hospital",
   "group_short": "Hanglok-Tech",
   "family": "academic",
   "category": "academic",
   "first_year": 2024,
   "latest_year": 2026,
   "versions": "wang2024_vision (CBS 2024, phantom in an interventional suite) -> zhu2026_bending (T-RO 2026, adds phantom paths and in vivo trials)",
   "target_anatomy": "head-and-neck / arch phantom (Elastrat); porcine vessels",
   "devices": [
    "guidewire",
    "microcatheter",
    "catheter",
    "sheath"
   ],
   "devices_driven": "0.014 in microwire, guide catheter (8 F sheath in phantom), microcatheter; contrast injection module",
   "n_dof": null,
   "n_dof_detail": "N.R.",
   "translation_mechanism": "other",
   "translation_detail": "other: microwire by an electric-gripper clamp on a lead-screw carriage with reverse drive (alternate clamp/release); microcatheter by dual friction wheels with multitooth Shore A70 silicone sleeve; guide catheter by advance-rotation module with Y-valve",
   "rotation_mechanism": "rotating-clamp",
   "rotation_detail": "Microwire twisted by the clamp ('guidewire twister', not friction wheels); guide catheter rotated through bevel gears and clutch",
   "device_range": "0.014 in microwire (nominal 0.36 mm); catheter sizes N.R.",
   "footprint_mm": "800x400x250 (jin2025_natural Sec. III-C)",
   "mass_kg": "N.R.",
   "force_sensing": "Pressure and torque sensors on USART ports of the embedded boards (zhu2026 Fig. 5); no force numbers reported in the sections read",
   "haptics_leader": "Hand-held controller with joystick and touch screen (no haptics described)",
   "imaging_compat": "Runs in a clinical angiography suite with DSA frames fed to the controller (X-ray)",
   "sterility": "Disinfected end effector; disposable contrast injector; further sterile-barrier detail N.R.",
   "highest_validation": "animal",
   "validation_detail": "Phantom: six vascular paths. Animal: nine in vivo vessel-navigation trials in pigs under IACUC approval of 20 Feb 2024 (zhu2026).",
   "key_numbers": "Vision co-pilot lowered the mean maximum bending-risk value 113.0 -> 49.0 in phantom (-56.6 %) and 239.8 -> 80.5 in animals (-66.4 %) (zhu2026 abstract)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "photo",
    "source": "jin2025_natural Fig. 6(b) (prototype of the follower manipulator, MULLER, designed by Zhuhai Hanglok per Sec. III-C), T-HMS 2025, doi:10.1109/THMS.2025.3591542",
    "source_url": "https://doi.org/10.1109/THMS.2025.3591542",
    "licence": "publisher copyright",
    "credit": "Jin et al., IEEE Transactions on Human-Machine Systems (2025), Fig. 6(b). publisher copyright.",
    "edits": "native extract (2000x1931 figure); main cropped to the drive unit",
    "file": null
   },
   "pictures": [
    {
     "id": "hanglok_wang2024_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "MULLER follower on the angiography table beside the DSA device",
     "source_key": "jin2025_natural",
     "source": "Jin et al., IEEE Transactions on Human-Machine Systems (2025), Fig. 6(c), p. 5",
     "source_url": "https://doi.org/10.1109/thms.2025.3591542",
     "where": "Fig. 6(c), p. 5",
     "licence": "publisher copyright"
    },
    {
     "id": "hanglok_wang2024_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Robot in the intervention room during the Bama pig trial",
     "source_key": "zhu2026_bending",
     "source": "Zhu et al., IEEE Transactions on Robotics (2026), Fig. 9(b), p. 10",
     "source_url": "https://doi.org/10.1109/tro.2026.3712458",
     "where": "Fig. 9(b), p. 10",
     "licence": "publisher copyright"
    },
    {
     "id": "hanglok_wang2024_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Robot with the aortic phantom, control room and intervention room",
     "source_key": "zhu2026_bending",
     "source": "Zhu et al., IEEE Transactions on Robotics (2026), Fig. 9(a), p. 10",
     "source_url": "https://doi.org/10.1109/tro.2026.3712458",
     "where": "Fig. 9(a), p. 10",
     "licence": "publisher copyright"
    },
    {
     "id": "hanglok_wang2024_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Follower manipulator, haptic leader device and joystick on the bench",
     "source_key": "jin2025_natural",
     "source": "Jin et al., IEEE Transactions on Human-Machine Systems (2025), Fig. 12, p. 7",
     "source_url": "https://doi.org/10.1109/thms.2025.3591542",
     "where": "Fig. 12, p. 7",
     "licence": "publisher copyright"
    },
    {
     "id": "hanglok_wang2024_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Follower CAD with the disposable consumable lid open",
     "source_key": "jin2025_natural",
     "source": "Jin et al., IEEE Transactions on Human-Machine Systems (2025), Fig. 6(a), p. 5",
     "source_url": "https://doi.org/10.1109/thms.2025.3591542",
     "where": "Fig. 6(a), p. 5",
     "licence": "publisher copyright"
    },
    {
     "id": "hanglok_wang2024_06",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "System modules in the interventional operating room, robot on the table",
     "source_key": "wang2024_vision",
     "source": "Wang et al., 2024 IEEE International Conference on Cyborg and Bionic Systems (CBS) (2024), Fig. 5 (left), p. 5",
     "source_url": "https://doi.org/10.1109/cbs61689.2024.10860327",
     "where": "Fig. 5 (left), p. 5",
     "licence": "publisher copyright"
    },
    {
     "id": "hanglok_wang2024_07",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD of the microwire advancement and guide-catheter modules",
     "source_key": "zhu2026_bending",
     "source": "Zhu et al., IEEE Transactions on Robotics (2026), Fig. 4(b)-(c), p. 5",
     "source_url": "https://doi.org/10.1109/tro.2026.3712458",
     "where": "Fig. 4(b)-(c), p. 5",
     "licence": "publisher copyright"
    },
    {
     "id": "hanglok_wang2024_08",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Hand-held control unit with control stick, motor and circuit board",
     "source_key": "zhu2026_bending",
     "source": "Zhu et al., IEEE Transactions on Robotics (2026), Fig. 6, p. 6",
     "source_url": "https://doi.org/10.1109/tro.2026.3712458",
     "where": "Fig. 6, p. 6",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "wang2024_vision",
     "doi": "10.1109/cbs61689.2024.10860327",
     "url": null,
     "title": "Vision Servoing Endovascular Interventional Robot System: Design and Verification",
     "year": 2024,
     "venue": "2024 IEEE International Conference on Cyborg and Bionic Systems (CBS)"
    },
    {
     "key": "zhu2026_bending",
     "doi": "10.1109/tro.2026.3712458",
     "url": null,
     "title": "Bending-Aware Vision Co-Pilot for Intelligent Robotic Assistance in Endovascular Intervention",
     "year": 2026,
     "venue": "IEEE Transactions on Robotics"
    },
    {
     "key": "jin2025_natural",
     "doi": "10.1109/thms.2025.3591542",
     "url": null,
     "title": "Natural Human–Robot Interaction for Vascular Interventional Surgery: Design and Evaluation of a Leader Device With Haptic Feedback",
     "year": 2025,
     "venue": "IEEE Transactions on Human-Machine Systems"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (wang2024, zhu2026 text); abstract (jin2025)",
   "notes": "Hanglok is a company; commercial status was not established in the papers, so the row is filed as academic with a company-affiliated prototype. The perception module is a trained DSA segmentation network, but it was not trained in simulation. | 2026-10-13 coordinator: footprint from jin2025_natural Sec. III-C (MULLER follower; W4, P2)",
   "maintainers_own": false,
   "found_by": "academic"
  },
  {
   "schema_version": 1,
   "id": "sjtu_xie_shen2019",
   "name": "SJTU hybrid drive",
   "full_name": "SJTU master-slave vascular intervention robot with progressive (friction + clamp) drive and force display",
   "group": "Shanghai Jiao Tong University School of Biomedical Engineering (Le Xie; Hao Shen, Cheng Wang, Shuang Wang, Zheng Liu) with Chinese Academy of Sciences and Peking Union Medical College Hospital",
   "group_short": "SJTU",
   "family": "academic",
   "category": "academic",
   "first_year": 2019,
   "latest_year": 2024,
   "versions": "xiang2019_masterslave (RO-MAN 2019: guidewire between two electric grippers on a lead-screw base, balloon catheter by friction wheels, two master manipulators, Kalman filter) -> shen2019_novel (IJCARS 2019: hybrid progressive drive, contrast injector, Omega 3 leader, in vivo swine) -> liu2022_magnetorheological (MRF leader, abstract not read) -> wang2024_improved (force sensors integrated, admittance control); 2016-17: earlier SJTU (Le Xie, Hao Shen) lead-screw catheter/guidewire pusher with a chuck on an ATI Nano43 six-axis sensor (Lin et al. 2016, Machine Design & Research), run by Wuhan Univ. of Technology as MISR with a Phantom Omni, 3:1 motion scaling and vibration warning, PVC-tube phantom (Xie 2017 ACIRS; Alekseeva 2025 Table 3 row 3, Fig. 10b) (xie2017_masterslave; alekseeva2025_design); 2012: guidewire tele-manipulation system with a laser-mouse-sensor motion detector as leader and a guidewire manipulation appliance, tested by operating time against tip-to-target distance and angle (Shen 2012 Zhongguo Yi Liao Qi Xie Za Zhi 36:32-35, PMID 22571149); group link only by Zhao 2022 Table 1 row 10c (PubMed affiliation: The 455 Hospital of PLA, Shanghai 200240) (shen2012_design; zhao2022_remote)",
   "target_anatomy": "carotid and coronary (swine; left coronary silicone model)",
   "devices": [
    "guidewire",
    "therapeutic-device"
   ],
   "devices_driven": "guidewire (0.035 in in wang2024), balloon catheter, plus contrast injector",
   "n_dof": 3,
   "n_dof_detail": "3 plus injector (S8 evidence reading of shen2019)",
   "translation_mechanism": "other",
   "translation_detail": "friction-roller + clamp hybrid ('progressive' drive; guidewire clamps on a shifting board, balloon catheter on a friction module; shen2019 Fig. 1c)",
   "rotation_mechanism": "not-reported",
   "rotation_detail": "Guidewire rotation by the actuator (mechanism detail not extracted; text of shen2019 is column-mangled)",
   "device_range": "0.035 in guidewire (wang2024)",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "Force and torque at the drive (shen2019); wang2024 adds force sensors at the proximal guidewire and electromagnetic (Aurora) sensors at both ends for delivered motion",
   "haptics_leader": "Omega 3 (Force Dimension) in a console with display (shen2019 Fig. 1a); MRF leader in liu2022",
   "imaging_compat": "X-ray angiography in the swine trials; MR N.R.",
   "sterility": "N.R.",
   "highest_validation": "animal",
   "validation_detail": "shen2019: bench performance tests plus four in vivo swine trials including carotid stent revascularisation; wang2024: silicone left-coronary model, five repeats per condition",
   "key_numbers": "Translational error <= 0.45 %, rotational error <= 2.6 deg, contrast injection error < 0.2 mL (shen2019 abstract); safety threshold 0.3 N and distal error larger than proximal error (wang2024, S8 evidence)",
   "sim_model": "none found (control simulations in MATLAB only)",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "render",
    "source": "shen2019_novel Fig. 1(b) (patient-side system: robotic arm, actuator, table, C-arm), IJCARS 2019, doi:10.1007/s11548-018-01906-w",
    "source_url": "https://doi.org/10.1007/s11548-018-01906-w",
    "licence": "publisher copyright",
    "credit": "Shen et al., International Journal of Computer Assisted Radiology and Surgery (2019), Fig. 1(b). publisher copyright.",
    "edits": "native extract (2032x1561); cropped to panel (b); 4 text tags and 4 leader arrows erased on the plain grey render background (LaMa, two passes); not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "sjtu_xie_shen2019_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Slave robot on the table and master console with two Falcons",
     "source_key": "wang2024_improved",
     "source": "Wang et al., International Journal of Computer Assisted Radiology and Surgery (2023), Fig. 2(b), p. 3",
     "source_url": "https://doi.org/10.1007/s11548-023-03017-7",
     "where": "Fig. 2(b), p. 3",
     "licence": "publisher copyright"
    },
    {
     "id": "sjtu_xie_shen2019_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Bench setup: Falcon, actuation unit, slave robot, vascular model, EM tracker",
     "source_key": "wang2024_improved",
     "source": "Wang et al., International Journal of Computer Assisted Radiology and Surgery (2023), Fig. 8, p. 9",
     "source_url": "https://doi.org/10.1007/s11548-023-03017-7",
     "where": "Fig. 8, p. 9",
     "licence": "publisher copyright"
    },
    {
     "id": "sjtu_xie_shen2019_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "Slave robot on the bench with the vascular phantom in its box",
     "source_key": "xiang2019_masterslave",
     "source": "Xiang et al., 2019 28th IEEE International Conference on Robot and Human Interactive Communication (RO-MAN) (2019), Fig. 5(a), p. 5",
     "source_url": "https://doi.org/10.1109/ro-man46459.2019.8956423",
     "where": "Fig. 5(a), p. 5",
     "licence": "publisher copyright"
    },
    {
     "id": "sjtu_xie_shen2019_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD of the slave: catheter and guidewire translation and rotation modules",
     "source_key": "wang2024_improved",
     "source": "Wang et al., International Journal of Computer Assisted Radiology and Surgery (2023), Fig. 2(a), p. 3",
     "source_url": "https://doi.org/10.1007/s11548-023-03017-7",
     "where": "Fig. 2(a), p. 3",
     "licence": "publisher copyright"
    },
    {
     "id": "sjtu_xie_shen2019_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Master side: two Omega haptic devices and the control laptop",
     "source_key": "xiang2019_masterslave",
     "source": "Xiang et al., 2019 28th IEEE International Conference on Robot and Human Interactive Communication (RO-MAN) (2019), Fig. 5(b), p. 5",
     "source_url": "https://doi.org/10.1109/ro-man46459.2019.8956423",
     "where": "Fig. 5(b), p. 5",
     "licence": "publisher copyright"
    },
    {
     "id": "sjtu_xie_shen2019_06",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Top view of the actuator: guidewire, balloon and injector modules",
     "source_key": "shen2019_novel",
     "source": "Shen et al., International Journal of Computer Assisted Radiology and Surgery (2019), Fig. 1(c), p. 3",
     "source_url": "https://doi.org/10.1007/s11548-018-01906-w",
     "where": "Fig. 1(c), p. 3",
     "licence": "publisher copyright"
    },
    {
     "id": "sjtu_xie_shen2019_07",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Master console platform with display centre and Omega 3",
     "source_key": "shen2019_novel",
     "source": "Shen et al., International Journal of Computer Assisted Radiology and Surgery (2019), Fig. 1(a), p. 3",
     "source_url": "https://doi.org/10.1007/s11548-018-01906-w",
     "where": "Fig. 1(a), p. 3",
     "licence": "publisher copyright"
    },
    {
     "id": "sjtu_xie_shen2019_08",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Slave mechanism with guidewire/catheter, balloon and contrast modules",
     "source_key": "xiang2019_masterslave",
     "source": "Xiang et al., 2019 28th IEEE International Conference on Robot and Human Interactive Communication (RO-MAN) (2019), Fig. 1, p. 2",
     "source_url": "https://doi.org/10.1109/ro-man46459.2019.8956423",
     "where": "Fig. 1, p. 2",
     "licence": "publisher copyright"
    },
    {
     "id": "sjtu_xie_shen2019_09",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "Xie 2017 MISR",
     "source_key": "xie2017_masterslave",
     "source": "Xie et al., 2017 2nd Asia-Pacific Conference on Intelligent Robot Systems (ACIRS) (2017), xie2017_masterslave Fig. 1 experimental scene, p. 2",
     "source_url": "https://doi.org/10.1109/ACIRS.2017.7986099",
     "where": "xie2017_masterslave Fig. 1 experimental scene, p. 2",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "sjtu_xie_shen2019_10",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "Xie 2017 MISR: Slave rail with conduit support, sensor clamp and rotating device (labelled)",
     "source_key": "xie2017_masterslave",
     "source": "Xie et al., 2017 2nd Asia-Pacific Conference on Intelligent Robot Systems (ACIRS) (2017), Fig. 2(d), p. 2",
     "source_url": "https://doi.org/10.1109/ACIRS.2017.7986099",
     "where": "Fig. 2(d), p. 2",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "sjtu_xie_shen2019_11",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Xie 2017 MISR: Main console: Phantom Omni handle and the control PC",
     "source_key": "xie2017_masterslave",
     "source": "Xie et al., 2017 2nd Asia-Pacific Conference on Intelligent Robot Systems (ACIRS) (2017), Fig. 3, p. 2",
     "source_url": "https://doi.org/10.1109/ACIRS.2017.7986099",
     "where": "Fig. 3, p. 2",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "sjtu_xie_shen2019_12",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Xie 2017 MISR: Chuck and six-axis force sensor mount of the slave (CAD)",
     "source_key": "xie2017_masterslave",
     "source": "Xie et al., 2017 2nd Asia-Pacific Conference on Intelligent Robot Systems (ACIRS) (2017), Fig. 2(c), p. 2",
     "source_url": "https://doi.org/10.1109/ACIRS.2017.7986099",
     "where": "Fig. 2(c), p. 2",
     "licence": "publisher copyright (IEEE)"
    }
   ],
   "sources": [
    {
     "key": "shen2019_novel",
     "doi": "10.1007/s11548-018-01906-w",
     "url": null,
     "title": "A novel robotic system for vascular intervention: principles, performances, and applications",
     "year": 2019,
     "venue": "International Journal of Computer Assisted Radiology and Surgery"
    },
    {
     "key": "xiang2019_masterslave",
     "doi": "10.1109/ro-man46459.2019.8956423",
     "url": null,
     "title": "Master-Slave Guidewire and Catheter Robotic System for Cardiovascular Intervention",
     "year": 2019,
     "venue": "2019 28th IEEE International Conference on Robot and Human Interactive Communication (RO-MAN)"
    },
    {
     "key": "wang2024_improved",
     "doi": "10.1007/s11548-023-03017-7",
     "url": null,
     "title": "Improved precise guidewire delivery of a cardiovascular interventional surgery robot based on admittance control",
     "year": 2023,
     "venue": "International Journal of Computer Assisted Radiology and Surgery"
    },
    {
     "key": "liu2022_magnetorheological",
     "doi": "10.1007/s10846-022-01716-y",
     "url": null,
     "title": "A Magnetorheological Fluid Based Force Feedback Master Robot for Vascular Interventional Surgery",
     "year": 2022,
     "venue": "Journal of Intelligent &amp; Robotic Systems"
    },
    {
     "key": "xie2017_masterslave",
     "doi": "10.1109/ACIRS.2017.7986099",
     "url": null,
     "title": "Research and implementation of master-slave control for interventional robot system",
     "year": 2017,
     "venue": "2017 2nd Asia-Pacific Conference on Intelligent Robot Systems (ACIRS)"
    },
    {
     "key": "alekseeva2025_design",
     "doi": "10.1002/rob.22480",
     "url": null,
     "title": "The Design of Endovascular Robots for Cardiac Interventions: A Survey",
     "year": 2024,
     "venue": "Journal of Field Robotics"
    },
    {
     "key": "shen2012_design",
     "doi": null,
     "url": null,
     "title": null,
     "year": null,
     "venue": null
    },
    {
     "key": "zhao2022_remote",
     "doi": "10.21037/qims-21-792",
     "url": null,
     "title": "Remote vascular interventional surgery robotics: a literature review",
     "year": 2022,
     "venue": "Quantitative Imaging in Medicine and Surgery"
    }
   ],
   "read_level": "partial",
   "read_level_detail": "partial (shen2019, wang2024, xiang2019 text); abstract (liu2022)",
   "notes": "S8 evidence lists this system as 'SJTU-SIAT'; the shen2019 affiliation lines show SJTU, a CAS institute in Beijing and PUMCH, so SIAT is not confirmed.",
   "maintainers_own": false,
   "found_by": "academic"
  },
  {
   "schema_version": 1,
   "id": "siat_omisore2018",
   "name": "SIAT belt grasper",
   "full_name": "SIAT second-generation robotic catheter system for cardiovascular intervention (belt-driven graspers)",
   "group": "Shenzhen Institutes of Advanced Technology, CAS (Lei Wang; Olatunji Mumini Omisore)",
   "group_short": "SIAT",
   "family": "academic",
   "category": "academic",
   "first_year": 2018,
   "latest_year": 2018,
   "versions": "omisore2018_towards (TBCAS 2018, second generation); the same lab's third-generation isomorphic primary-secondary system (du2024_analyzing, omisore2024_sample, duan2025_development) is row siat_haptic_duan2025; 2011-14: SIAT first-generation master-slave robot (P. Zhang 2011 ICMA; Mi 2014 ICMA) (Alekseeva 2025 Table 2 row 5; Belikov 2024 Fig. 6 MIs; Zhao 2022 Table 1 row 15b) (alekseeva2025_design; belikov2024_evolution; zhao2022_remote)",
   "target_anatomy": "radial artery through axillary and subclavian arteries to the aortic arch (tubular phantoms)",
   "devices": [
    "catheter",
    "sheath"
   ],
   "devices_driven": "one 9 Fr, 130 cm unactuated catheter sheath (no steerable catheters)",
   "n_dof": 2,
   "n_dof_detail": "2 (axial translation, rotation)",
   "translation_mechanism": "belt/track",
   "translation_detail": "belt/track",
   "rotation_mechanism": "rotating-clamp",
   "rotation_detail": "Rotary drive grasper on a Maxon EC16 motor; belt carries four axial drive graspers for continuous push (Maxon EC32)",
   "device_range": "9 Fr catheter sheath; two guiding sheaths of 35 mm length, 10 mm inner diameter at the belt ends",
   "footprint_mm": "400 x 180 x 150",
   "mass_kg": "about 9.5 (S8 evidence reading of Sec. II-C); battery 10,000 mAh, 220 +/- 27 min",
   "force_sensing": "Strain gauges on the 9 Fr sheath, 5 mm and 25 mm from the tip (gauge factor 2.08, 120 ohm), Coulomb friction term subtracted; EM sensor (NDI Aurora) in the lumen for tip motion",
   "haptics_leader": "none in this paper",
   "imaging_compat": "N.R.",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "Tubular PVC phantoms (10 mm) from the radial artery to the aortic arch; one insertion with compensation and none without (S8 reading)",
   "key_numbers": "Backlash gaps 3.94-9.30 mm between motor encoder and tip EM sensor; adaptive neuro-fuzzy compensation final error 0.4 mm (duan2023_progress, review statement); sensor accuracy 0.9 mm / 0.8 deg",
   "sim_model": "none found for the robot",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found for this generation. The 2024 DRL PID-tuning study (omisore2024_sample, full) ran on the current-generation slave (Sec. II-A: \"The current generation is an isomorphic master-slave RCS\"; 57 x 22 x 16 cm, 4 DoF), not on this belt-driven robot: see row siat_haptic_duan2025.",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "photo",
    "source": "omisore2018_towards Fig. 13 (experimental setup, robot outlined in red), TBCAS 2018, doi:10.1109/TBCAS.2018.2825359",
    "source_url": "https://doi.org/10.1109/TBCAS.2018.2825359",
    "licence": "publisher copyright",
    "credit": "Omisore et al., IEEE Transactions on Biomedical Circuits and Systems (2018), Fig. 13. publisher copyright.",
    "edits": "native extract (2050x1275 figure, soft source photo); cropped; red outline, red arrow, label box and a yellow leader erased (LaMa, colour mask + boxes); not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "siat_omisore2018_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD of the second-generation robot: axial graspers, rotary grasper, actuators",
     "source_key": "omisore2018_towards",
     "source": "Omisore et al., IEEE Transactions on Biomedical Circuits and Systems (2018), Fig. 1, p. 2",
     "source_url": "https://doi.org/10.1109/tbcas.2018.2825359",
     "where": "Fig. 1, p. 2",
     "licence": "publisher copyright"
    },
    {
     "id": "siat_omisore2018_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Catheter tip with strain-gauge force sensors and plastic holder",
     "source_key": "omisore2018_towards",
     "source": "Omisore et al., IEEE Transactions on Biomedical Circuits and Systems (2018), Fig. 2, p. 3",
     "source_url": "https://doi.org/10.1109/tbcas.2018.2825359",
     "where": "Fig. 2, p. 3",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "omisore2018_towards",
     "doi": "10.1109/tbcas.2018.2825359",
     "url": null,
     "title": "Towards Characterization and Adaptive Compensation of Backlash in a Novel Robotic Catheter System for Cardiovascular Interventions",
     "year": 2018,
     "venue": "IEEE Transactions on Biomedical Circuits and Systems"
    },
    {
     "key": "duan2023_progress",
     "doi": "10.3390/mi14010197",
     "url": null,
     "title": "Technical and Clinical Progress on Robot-Assisted Endovascular Interventions: A Review",
     "year": 2023,
     "venue": "Micromachines"
    },
    {
     "key": "alekseeva2025_design",
     "doi": "10.1002/rob.22480",
     "url": null,
     "title": "The Design of Endovascular Robots for Cardiac Interventions: A Survey",
     "year": 2024,
     "venue": "Journal of Field Robotics"
    },
    {
     "key": "belikov2024_evolution",
     "doi": "10.1016/j.jestch.2024.101789",
     "url": null,
     "title": "Evolution and current state of robotic catheters for endovascular surgery: A comprehensive review",
     "year": 2024,
     "venue": "Engineering Science and Technology, an International Journal"
    },
    {
     "key": "zhao2022_remote",
     "doi": "10.21037/qims-21-792",
     "url": null,
     "title": "Remote vascular interventional surgery robotics: a literature review",
     "year": 2022,
     "venue": "Quantitative Imaging in Medicine and Surgery"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (omisore2018 via S8 evidence + figures); omisore2024_sample full text read 2026-10-14 and moved to row siat_haptic_duan2025",
   "notes": "Fig. 1 of the paper is a CAD model; the setup photo was chosen as the prototype image. F4 2026-10-14: omisore2024_sample removed from this row (it describes the current, isomorphic generation).",
   "maintainers_own": false,
   "found_by": "academic"
  },
  {
   "schema_version": 1,
   "id": "siat_haptic_duan2025",
   "name": "SIAT haptic robot",
   "full_name": "SIAT third-generation isomorphic primary-secondary robotic catheter system with haptic-enabled primary (clamp-relay secondary manipulator, magnetic-powder-brake primary interface)",
   "group": "Shenzhen Institutes of Advanced Technology, CAS (Lei Wang, Hongbo Wang, Olatunji Omisore) with Fudan University (Wenke Duan)",
   "group_short": "SIAT / Fudan",
   "family": "academic",
   "category": "academic",
   "first_year": 2023,
   "latest_year": 2025,
   "versions": "third generation cited to 2022 (du2024 Sec. II-A ref. [25], Du et al., T-MRB 2022; not read) -> 2024 improved prototype that logs proximal and distal force, 168 trials by surgeons and novices in a coronary phantom (du2024_analyzing, full) -> 2024 4-DoF slave-side device in a white branded housing on an arm, PID gains tuned by deep RL in a CoppeliaSim model (omisore2024_sample, full) -> 2025 primary haptic interface with magnetic powder brake and a resistance-detection module on the clamp (duan2025_development, ToH 2025)",
   "target_anatomy": "cardiovascular model with pulse pump (right coronary artery, stenoses)",
   "devices": [
    "guidewire",
    "catheter"
   ],
   "devices_driven": "guidewire / catheter (one tool at a time; sizes N.R.): guidewire through a guiding catheter into the anterior descending branch (du2024 Sec. II-B); \"flexible endovascular tools such as catheter and guidewire\" (omisore2024 Sec. II)",
   "n_dof": 4,
   "n_dof_detail": "4 on the secondary manipulator (clamping, delivery, rotation, orientation adjustment; duan2025 Sec. II-B); \"a robotic 4-DoF mechanism\", of which axial translation and axial rotation are used (omisore2024 Sec. II-A)",
   "translation_mechanism": "clamp-relay",
   "translation_detail": "clamp-relay",
   "rotation_mechanism": "other",
   "rotation_detail": "Rotation module with self-aligning roller bearing and four balance springs (mechanism details N.R.) du2024 and omisore2024 defer the drive mechanism to earlier papers (du2024 Sec. II-D ref. [29]; omisore2024 Sec. II-A ref. [20]).",
   "device_range": "N.R.",
   "footprint_mm": "570 x 220 x 160 (slave-side device; omisore2024 Sec. II-A: \"57x22x16 cm\"); secondary travel 150 mm per stroke (duan2025 Sec. II-B)",
   "mass_kg": "N.R.",
   "force_sensing": "Proximal vessel-tool interaction force: axial resistance pushes the tool against clamp A, which compresses a bearing plate on LFS-13-10N sensors (Ligent, Shenzhen) 2024 prototype (du2024 Sec. II-A, II-D3 to II-D5): proximal axial force sensor on the secondary's slider (SBT674-2kg, range 19.6 N) measures friction plus tool-tissue force; a 32-channel flexible pressure sensor on the primary control ring (0.01-19.6 N) measures the operator's finger force; distal tool-tissue force comes from a 6-axis F/T sensor (SBT308, 49 N per axis, composite error 1.0 %) under the phantom, not on the robot. omisore2024 Sec. II-A: \"in-built sensing units for position and force feedback\".",
   "haptics_leader": "Primary interface with magnetic powder brake; dynamic hysteresis compensation model; human-perception-based haptic enhancement amplifying low-force changes and a safety strategy The 2024 primary uses the same motion sensors as the 2025 interface (magnetostrictive position sensor SDM20T-0150, rotary encoder E40H12-1000-3; du2024 Sec. II-D, duan2025 Sec. II-A); du2024 renders no force to the operator. omisore2024: master with a control knob and potentiometer, commands over TCP/IP with about 0.1 s delay (Sec. II-A, IV-C).",
   "imaging_compat": "N.R.",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "Haptic force calibration, then robot-assisted catheterisation in a cardiovascular model; human-subject study approved by SIAT-IRB-220915-H0606 (participant count not extracted) du2024: 168 robot-assisted trials, 12 per subject, in a 1:1 adult vascular simulator with pulsatile blood-like fluid; path with one branch, two stenoses (37.45 %, 42.69 %) and a tortuous part; group A 10 subjects without and group B 5 with manual PCI experience (168 / 12 = 14, so Sec. II-B and II-E2 disagree on the count); same IRB approval SIAT-IRB-220915-H0606 (du2024 p. 1, Sec. II-B, II-E2). omisore2024: bench only, 1 mm displacement commands on the slave-side device, number of runs N.R. (Sec. IV-C, Fig. 7).",
   "key_numbers": "Stroke 150 mm; haptic enhancement and hysteresis compensation as the stated contributions; no headline error numbers extracted du2024: CNN recognition of operator-robot cooperation 99.99 % (test set); synergy ratios 89.66 %, 90.28 % and 91.12 % \"based on the three aspects of delay consideration\" for experienced operators; constant delay modelled as 0.254 s (Abstract, Sec. III). omisore2024: on the robot, displacement error within +/-2 x 10^-2 mm (Sec. IV-C, Fig. 7); in CoppeliaSim, DRL-PID error 0.003 +/- 0.0058 mm vs 0.012 +/- 0.009 (Ziegler-Nichols PID) and 0.015 +/- 0.011 mm (fuzzy PID), 10 trials of 100 set-points each (Sec. IV-B).",
   "sim_model": "CoppeliaSim model of the slave-side robot: Solidworks CAD exported as URDF, prismatic and revolute joints for axial translation and rotation with parameterised static and dynamic variables and simulated position sensors; no vessel or device model (omisore2024_sample Sec. III-A, Fig. 3)",
   "has_sim_model": true,
   "sim2real": "partial",
   "sim2real_detail": "partial (motor level, bench; not a navigation controller): a deep-RL agent that tunes PID gains for axial translation was trained in the CoppeliaSim model of the slave (converged in 20 episodes of 100 steps); \"the final tuning parameters were exported and applied in the robotic system\" (Raspberry Pi 4), which tracked 1 mm displacement commands from the master knob within +/-2 x 10^-2 mm; no device, phantom or baseline on the hardware, number of runs N.R. (omisore2024_sample Sec. III-A, III-D, IV-C, Fig. 7)",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "photo",
    "source": "duan2025_development Fig. 13(a) (whole system platform, secondary manipulator), ToH 2025, doi:10.1109/TOH.2023.3346479",
    "source_url": "https://doi.org/10.1109/TOH.2023.3346479",
    "licence": "publisher copyright",
    "credit": "Duan et al., IEEE Transactions on Haptics (2025), Fig. 13(a). publisher copyright.",
    "edits": "native extract (4092x1548 figure); cropped between label boxes; not upscaled; a red pointer arrow touching the clamp module is left in place (it crosses the mechanism)",
    "file": null
   },
   "pictures": [
    {
     "id": "siat_haptic_duan2025_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "Slave device of the PCI robot on an articulated support arm",
     "source_key": "omisore2024_sample",
     "source": "Omisore et al., 2024 IEEE International Conference on Robotics and Biomimetics (ROBIO) (2024), Fig. 1, p. 3",
     "source_url": "https://doi.org/10.1109/robio64047.2024.10907735",
     "where": "Fig. 1, p. 3",
     "licence": "publisher copyright"
    },
    {
     "id": "siat_haptic_duan2025_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Master controller with joystick and the slave-side device",
     "source_key": "omisore2024_sample",
     "source": "Omisore et al., 2024 IEEE International Conference on Robotics and Biomimetics (ROBIO) (2024), Fig. 6, p. 6",
     "source_url": "https://doi.org/10.1109/robio64047.2024.10907735",
     "where": "Fig. 6, p. 6",
     "licence": "publisher copyright"
    },
    {
     "id": "siat_haptic_duan2025_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Primary haptic interface with magnetic powder brake on the test bench",
     "source_key": "duan2025_development",
     "source": "Duan et al., IEEE Transactions on Haptics (2025), Fig. 10, p. 7",
     "source_url": "https://doi.org/10.1109/toh.2023.3346479",
     "where": "Fig. 10, p. 7",
     "licence": "CC BY-NC-ND 4.0"
    },
    {
     "id": "siat_haptic_duan2025_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD of the secondary manipulator with clamping and resistance modules",
     "source_key": "duan2025_development",
     "source": "Duan et al., IEEE Transactions on Haptics (2025), Fig. 4, p. 4",
     "source_url": "https://doi.org/10.1109/toh.2023.3346479",
     "where": "Fig. 4, p. 4",
     "licence": "CC BY-NC-ND 4.0"
    },
    {
     "id": "siat_haptic_duan2025_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD of the primary haptic interface: handle, encoder, powder brake",
     "source_key": "duan2025_development",
     "source": "Duan et al., IEEE Transactions on Haptics (2025), Fig. 3, p. 3",
     "source_url": "https://doi.org/10.1109/toh.2023.3346479",
     "where": "Fig. 3, p. 3",
     "licence": "CC BY-NC-ND 4.0"
    },
    {
     "id": "siat_haptic_duan2025_06",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Resistance detection module between the tool clamp and force sensor",
     "source_key": "duan2025_development",
     "source": "Duan et al., IEEE Transactions on Haptics (2025), Fig. 5, p. 4",
     "source_url": "https://doi.org/10.1109/toh.2023.3346479",
     "where": "Fig. 5, p. 4",
     "licence": "CC BY-NC-ND 4.0"
    },
    {
     "id": "siat_haptic_duan2025_07",
     "status": "cleared",
     "file": "pictures/extra/siat_haptic_duan2025_07.jpg",
     "thumb": "pictures/thumbs/siat_haptic_duan2025_07.jpg",
     "kind": "leader",
     "caption": "Primary console shown in four guidewire manipulation patterns",
     "source_key": "du2024_analyzing",
     "source": "Du et al., IEEE Transactions on Human-Machine Systems (2024), Fig. 1, p. 3",
     "source_url": "https://doi.org/10.1109/thms.2024.3452975",
     "where": "Fig. 1, p. 3",
     "licence": "CC BY 4.0"
    },
    {
     "id": "siat_haptic_duan2025_08",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Slave robot model in the CoppeliaSim simulator",
     "source_key": "omisore2024_sample",
     "source": "Omisore et al., 2024 IEEE International Conference on Robotics and Biomimetics (ROBIO) (2024), Fig. 3, p. 5",
     "source_url": "https://doi.org/10.1109/robio64047.2024.10907735",
     "where": "Fig. 3, p. 5",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "duan2025_development",
     "doi": "10.1109/toh.2023.3346479",
     "url": null,
     "title": "Development of an Intuitive Interface With Haptic Enhancement for Robot-Assisted Endovascular Intervention",
     "year": 2025,
     "venue": "IEEE Transactions on Haptics"
    },
    {
     "key": "du2024_analyzing",
     "doi": "10.1109/thms.2024.3452975",
     "url": null,
     "title": "Analyzing Surgeon–Robot Cooperative Performance in Robot-Assisted Intravascular Catheterization",
     "year": 2024,
     "venue": "IEEE Transactions on Human-Machine Systems"
    },
    {
     "key": "omisore2024_sample",
     "doi": "10.1109/robio64047.2024.10907735",
     "url": null,
     "title": "A Novel Sample-Efficient Deep Reinforcement Learning with Episodic Policy Transfer for PID-Based Control in Robotic Catheter System",
     "year": 2024,
     "venue": "2024 IEEE International Conference on Robotics and Biomimetics (ROBIO)"
    },
    {
     "key": "omisore2018_towards",
     "doi": "10.1109/tbcas.2018.2825359",
     "url": null,
     "title": "Towards Characterization and Adaptive Compensation of Backlash in a Novel Robotic Catheter System for Cardiovascular Interventions",
     "year": 2018,
     "venue": "IEEE Transactions on Biomedical Circuits and Systems"
    }
   ],
   "read_level": "full",
   "read_level_detail": "partial (duan2025 text); full (du2024_analyzing, omisore2024_sample; 2026-10-14)",
   "notes": "Shows the SIAT move from belt-driven graspers (2018) to clamp-relay plus a force-sensing clamp (2023-25). F4 2026-10-14: du2024 and omisore2024 are attached here because they come from the same SIAT group (Lei Wang, Omisore, Duan, Du, Akinyemi), carry the same IRB number as duan2025, use the same primary-interface sensors as duan2025, and call the system the third / current isomorphic primary-secondary generation. omisore2024 Figs. 1 and 6 show the slave in a closed branded housing; duan2025 Fig. 13(a) shows an open clamp-relay manipulator. That they are one mechanism is not stated.",
   "maintainers_own": false,
   "found_by": "academic"
  },
  {
   "schema_version": 1,
   "id": "sjtu_coronary_meng2025",
   "name": "SJTU PCI robot",
   "full_name": "SJTU master-slave PCI robot with magnetic-coupling modular drive and thin-film force sensing",
   "group": "Shanghai Jiao Tong University, School of Mechanical Engineering (Meng, Fang, Jing, Fu et al.)",
   "group_short": "SJTU",
   "family": "academic",
   "category": "academic",
   "first_year": 2025,
   "latest_year": 2025,
   "versions": "meng2025_design (ROBIO 2025)",
   "target_anatomy": "coronary PCI (complex vascular geometries in simulation and bench)",
   "devices": [
    "guidewire",
    "catheter",
    "therapeutic-device"
   ],
   "devices_driven": "guidewire (0.014-0.035 in), guide catheter, balloon/stent catheter",
   "n_dof": 4,
   "n_dof_detail": "4 (guidewire advance and rotation; catheter linear insertion; balloon/stent linear transport)",
   "translation_mechanism": "friction-roller",
   "translation_detail": "friction-roller (guidewire: gear-driven dual friction wheels; balloon/stent: symmetric friction wheels; catheter: gear-rack clamping with linear drive)",
   "rotation_mechanism": "other",
   "rotation_detail": "Guidewire rotated continuously through drive wheel 1 and bevel gears (360 deg)",
   "device_range": "guidewire 0.014 in to 0.035 in",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "Thin-film pressure sensors between worm and housing give axial guidewire force",
   "haptics_leader": "N.R.",
   "imaging_compat": "N.R.",
   "sterility": "Electromechanical decoupling by magnetic coupling torque transmission so the distal module can be a hygienic, separable part",
   "highest_validation": "bench",
   "validation_detail": "Simulink control simulation plus hardware experiments; number of trials N.R.",
   "key_numbers": "Displacement error within +/-1 mm and angular error within +/-15 deg; Smith predictor + RBF self-tuning PID",
   "sim_model": "Simulink control-loop model only",
   "has_sim_model": true,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "render",
    "source": "meng2025_design Fig. 1 (structure of the robotic system), ROBIO 2025, doi:10.1109/ROBIO66223.2025.11378419",
    "source_url": "https://doi.org/10.1109/ROBIO66223.2025.11378419",
    "licence": "publisher copyright",
    "credit": "Meng et al., 2025 IEEE International Conference on Robotics and Biomimetics (ROBIO) (2025), Fig. 1. publisher copyright.",
    "edits": "figure rebuilt from its 19 embedded raster tiles at native scale (labels and leader lines are inside the tiles); main panel cropped; fragments of neighbouring panels whitened; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "sjtu_coronary_meng2025_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD of the guidewire drive module with an inset of the catheter module",
     "source_key": "meng2025_design",
     "source": "Meng et al., 2025 IEEE International Conference on Robotics and Biomimetics (ROBIO) (2025), Fig. 1 (right part), p. 2",
     "source_url": "https://doi.org/10.1109/robio66223.2025.11378419",
     "where": "Fig. 1 (right part), p. 2",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "meng2025_design",
     "doi": "10.1109/robio66223.2025.11378419",
     "url": null,
     "title": "Design and Control of a Robotic System for Coronary Interventions",
     "year": 2025,
     "venue": "2025 IEEE International Conference on Robotics and Biomimetics (ROBIO)"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (meng2025 text)",
   "notes": "CAD render only; no prototype photo in the paper.",
   "maintainers_own": false,
   "found_by": "academic"
  },
  {
   "schema_version": 1,
   "id": "hust_guidewire_li2024",
   "name": "HUST wire robot",
   "full_name": "HUST 2-DOF friction-wheel guidewire platform for autonomous navigation (centerline-guided)",
   "group": "Huazhong University of Science and Technology (Naner Li, Yiwei Wang, Huan Zhao, Han Ding)",
   "group_short": "HUST",
   "family": "academic",
   "category": "academic",
   "first_year": 2024,
   "latest_year": 2024,
   "versions": "li2024_vascular (ICRA 2024)",
   "target_anatomy": "clinical-grade interventional training model (arch and branches)",
   "devices": [
    "guidewire"
   ],
   "devices_driven": "0.035 in hydrophilic guidewire (Terumo)",
   "n_dof": 2,
   "n_dof_detail": "2",
   "translation_mechanism": "friction-roller",
   "translation_detail": "friction-roller (pair of friction wheels with silicone layer, belt-driven from one motor)",
   "rotation_mechanism": "roller-rolling",
   "rotation_detail": "Wheel pair translated in opposite directions by a screw-driven motor, rubbing the wire to rotate it (Fig. 1d)",
   "device_range": "0.035 in",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "none",
   "haptics_leader": "none (autonomous; manual baseline also run)",
   "imaging_compat": "No X-ray: Aurora electromagnetic tip tracking replaces imaging",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "96 trials: four methods (manual, trial-and-error, centerline-guided, DTW variant) on several routes, eight repeats per route",
   "key_numbers": "Autonomous methods beat manual in trajectory smoothness, length and wrong-branch entries in a static model; manual was fastest (platform speed-limited)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found (S7b evidence: sim_to_real_tested = no)",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "photo",
    "source": "li2024_vascular Fig. 1(a) region 1 (platform, top view), ICRA 2024, doi:10.1109/ICRA57147.2024.10611329",
    "source_url": "https://doi.org/10.1109/ICRA57147.2024.10611329",
    "licence": "publisher copyright",
    "credit": "Li et al., 2024 IEEE International Conference on Robotics and Automation (ICRA) (2024), Fig. 1(a). publisher copyright.",
    "edits": "native extract (1030x694 figure); cropped inside the yellow dashed box and below its number tag; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "hust_guidewire_li2024_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Platform, console laptop, phantom and NDI tracker on the bench",
     "source_key": "li2024_vascular",
     "source": "Li et al., 2024 IEEE International Conference on Robotics and Automation (ICRA) (2024), Fig. 1(a), p. 1",
     "source_url": "https://doi.org/10.1109/icra57147.2024.10611329",
     "where": "Fig. 1(a), p. 1",
     "licence": "publisher copyright"
    },
    {
     "id": "hust_guidewire_li2024_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD of the platform: friction-wheel shafts, Motor 1 and Motor 2",
     "source_key": "li2024_vascular",
     "source": "Li et al., 2024 IEEE International Conference on Robotics and Automation (ICRA) (2024), Fig. 1(b), p. 1",
     "source_url": "https://doi.org/10.1109/icra57147.2024.10611329",
     "where": "Fig. 1(b), p. 1",
     "licence": "publisher copyright"
    },
    {
     "id": "hust_guidewire_li2024_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Rotation principle: friction wheels sliding in opposite directions",
     "source_key": "li2024_vascular",
     "source": "Li et al., 2024 IEEE International Conference on Robotics and Automation (ICRA) (2024), Fig. 1(d), p. 1",
     "source_url": "https://doi.org/10.1109/icra57147.2024.10611329",
     "where": "Fig. 1(d), p. 1",
     "licence": "publisher copyright"
    },
    {
     "id": "hust_guidewire_li2024_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Advance principle: paired friction wheels gripping the guidewire",
     "source_key": "li2024_vascular",
     "source": "Li et al., 2024 IEEE International Conference on Robotics and Automation (ICRA) (2024), Fig. 1(c), p. 1",
     "source_url": "https://doi.org/10.1109/icra57147.2024.10611329",
     "where": "Fig. 1(c), p. 1",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "li2024_vascular",
     "doi": "10.1109/icra57147.2024.10611329",
     "url": null,
     "title": "Vascular Centerline-Guided Autonomous Navigation Methods for Robot-Lead Endovascular Interventions",
     "year": 2024,
     "venue": "2024 IEEE International Conference on Robotics and Automation (ICRA)"
    }
   ],
   "read_level": "partial",
   "read_level_detail": "partial (li2024 text)",
   "notes": "Autonomy is rule/centerline based, not learned in simulation. F4 2026-10-14: li2025_sensorfree (RA-L 2025, same group, full) estimates guidewire shape and contact force from a graph shortest path plus a COMSOL finite-element model; \"the guidewire was manually inserted into the phantoms\" (Sec. IV-A), so it uses no robot and adds no picture.",
   "maintainers_own": false,
   "found_by": "academic"
  },
  {
   "schema_version": 1,
   "id": "unitedimaging_yao2025",
   "name": "United Imaging",
   "full_name": "United Imaging vascular interventional robot (VascularPilot3D platform)",
   "group": "United Imaging and United Imaging Research Institute of Intelligent Imaging, with U. Michigan (Ghaffari); also used by Tongji University (Tianliang Yao, Peng Qi), Soochow University (Bo Lu), Siemens Healthineers",
   "group_short": "UIH / Tongji",
   "family": "academic",
   "category": "academic",
   "first_year": 2024,
   "latest_year": 2025,
   "versions": "song2025_vascularpilot3d (arXiv 2405.09375 v1 2024-05-15; ICRA 2025): United Imaging's own robot carrying the VascularPilot3D navigation stack ('Our own robot was built', Sec. III, Fig. 5) -> yao2025_sim4endor (ICRA 2025, open-loop replay) -> yao2025_sim2real (T-ASE 2025)",
   "target_anatomy": "simplified vascular phantom and complex coronary phantom",
   "devices": [
    "guidewire"
   ],
   "devices_driven": "guidewire (simulated 0.9 mm radius, 1.55 g/cm3)",
   "n_dof": null,
   "n_dof_detail": "translation + rotation of the guidewire (Fig. 3 labels); count N.R.",
   "translation_mechanism": "not-reported",
   "translation_detail": "N.R. (robot only described as a 'specialized vascular intervention robot provided by United Imaging')",
   "rotation_mechanism": "not-reported",
   "rotation_detail": "N.R.",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "N.R.",
   "haptics_leader": "N.R.",
   "imaging_compat": "United Imaging uAngio 960 fluoroscopy, mean delay 0.2 s from the C-arm to the navigation software; pre-operative CT on uCT 860 (song2025_vascularpilot3d Sec. III)",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "Physical robot, Target B of a vascular phantom; 5 trials per RL method, 3 trials per human operator (yao2025_sim2real); autonomous navigation to 5 destinations in a transparent phantom under fluoroscopy, 5 trials each, which the paper calls ex-vivo (song2025_vascularpilot3d Sec. III, Fig. 5)",
   "key_numbers": "PPO+GAE+DR: 100 % success, 53.0 +/- 5.1 s, error 2.92 +/- 0.41 mm (A) and 2.06 +/- 0.31 mm (B); plain PPO 60 % in 61.0 +/- 4.8 s; SAC 75 % (45.0 s); DDPG 75 % (40.0 s); humans 100 % in 35.0 and 39.0 s (yao2025_sim2real); VascularPilot3D 25 of 25 autonomous navigations, 18.38 % fewer control loops than the human operator, one control step about 2 s (song2025_vascularpilot3d abstract, Sec. III)",
   "sim_model": "SOFA with BeamAdapter discrete-point guidewire model; anatomy from CT, built with Blender and Onshape; Sim4EndoR platform (yao2025_sim4endor)",
   "has_sim_model": true,
   "sim2real": "yes",
   "sim2real_detail": "yes: policy trained only in simulation (PPO with GAE and domain randomisation over friction and tissue elasticity) deployed on this robot with no real-time position feedback; sim 90 % (9/10, Target B) -> robot 100 % (5/5) (yao2025_sim2real, full). yao2025_sim4endor: robot 5/5 and 3/5, open-loop replay (S7b evidence)",
   "picture": {
    "status": "cleared",
    "grade": "A",
    "kind": "photo",
    "source": "song2025_vascularpilot3d Fig. 5, top panel (arXiv 2405.09375v2, p. 5, native raster 1052 x 1462)",
    "source_url": "https://arxiv.org/abs/2405.09375v2",
    "licence": "CC BY 4.0",
    "credit": "Song et al., 2025 IEEE International Conference on Robotics and Automation (ICRA) (2025), Fig. 5. CC BY 4.0.",
    "edits": "native extract; cropped to the top panel; nothing erased; none upscaled",
    "file": "pictures/unitedimaging_yao2025.jpg"
   },
   "pictures": [
    {
     "id": "unitedimaging_yao2025_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Robot on the operation table with phantom, C-arm and monitor",
     "source_key": "yao2025_sim2real",
     "source": "Yao et al., IEEE Transactions on Automation Science and Engineering (2025), Fig. 3, p. 10",
     "source_url": "https://doi.org/10.1109/tase.2025.3555559",
     "where": "Fig. 3, p. 10",
     "licence": "publisher copyright"
    },
    {
     "id": "unitedimaging_yao2025_02",
     "status": "cleared",
     "file": "pictures/extra/unitedimaging_yao2025_02.jpg",
     "thumb": "pictures/thumbs/unitedimaging_yao2025_02.jpg",
     "kind": "in-use",
     "caption": "Robot and vascular phantom on the angiography table",
     "source_key": "song2025_vascularpilot3d",
     "source": "Song et al., 2025 IEEE International Conference on Robotics and Automation (ICRA) (2025), Fig. 5 (middle left), p. 5, arXiv 2405.09375v2",
     "source_url": "https://doi.org/10.1109/icra55743.2025.11127370",
     "where": "Fig. 5 (middle left), p. 5, arXiv 2405.09375v2",
     "licence": "CC BY 4.0"
    }
   ],
   "sources": [
    {
     "key": "song2025_vascularpilot3d",
     "doi": "10.1109/icra55743.2025.11127370",
     "url": null,
     "title": "VascularPilot3D: Toward a 3D Fully Autonomous Navigation for Endovascular Robotics",
     "year": 2025,
     "venue": "2025 IEEE International Conference on Robotics and Automation (ICRA)"
    },
    {
     "key": "yao2025_sim2real",
     "doi": "10.1109/tase.2025.3555559",
     "url": null,
     "title": "Sim2Real Learning With Domain Randomization for Autonomous Guidewire Navigation in Robotic-Assisted Endovascular Procedures",
     "year": 2025,
     "venue": "IEEE Transactions on Automation Science and Engineering"
    },
    {
     "key": "yao2025_sim4endor",
     "doi": "10.1109/icra55743.2025.11127627",
     "url": null,
     "title": "Sim4EndoR: A Reinforcement Learning Centered Simulation Platform for Task Automation of Endovascular Robotics",
     "year": 2025,
     "venue": "2025 IEEE International Conference on Robotics and Automation (ICRA)"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (song2025_vascularpilot3d; yao2025_sim2real); S7b evidence (sim4endor)",
   "notes": "United Imaging built the robot itself ('Our own robot was built', song2025_vascularpilot3d Sec. III) and runs its navigation software on ROS on a laptop; no paper describes the drive mechanism. Same white two-cassette bedside unit on an arm as in yao2025_sim2real Fig. 3. Found 2026-11-07 by the user (arXiv 2405.09375), missed by the searches because the title names the navigation system, not the robot.",
   "maintainers_own": false,
   "found_by": "academic"
  },
  {
   "schema_version": 1,
   "id": "kaist_cho2022",
   "name": "KAIST wire bench",
   "full_name": "KAIST/Asan guidewire-controller test bench for image-based sim-to-real navigation",
   "group": "KAIST School of Electrical Engineering (Dong Eui Chang; Yongjun Cho, Sangbaek Yoo) with Asan Medical Center / University of Ulsan and LN Robotics (Jaesoon Choi)",
   "group_short": "KAIST / Asan",
   "family": "academic",
   "category": "academic",
   "first_year": 2021,
   "latest_year": 2025,
   "versions": "cho2022_sim (IROS 2022, DDPG+behaviour cloning) -> yoo2025_robust (ICRA 2025, PPO with domain randomisation); same test bench in both",
   "target_anatomy": "planar vessel phantom (bifurcating paths) on a bench; coronary-like trees in simulation",
   "devices": [
    "guidewire"
   ],
   "devices_driven": "one guidewire",
   "n_dof": 2,
   "n_dof_detail": "2 (translation 0.4 mm steps, rotation 10 deg steps in cho2022)",
   "translation_mechanism": "not-reported",
   "translation_detail": "N.R. (called 'a guidewire controller'; photo shows a compact block with wiring, mechanism not described)",
   "rotation_mechanism": "not-reported",
   "rotation_detail": "N.R.",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "none",
   "haptics_leader": "none",
   "imaging_compat": "Overhead camera replaces X-ray; image reduced to vessel and guidewire masks",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "cho2022: 40 phantom episodes; yoo2025: three tests of 40 runs each on one bench with four paths",
   "key_numbers": "cho2022: simulation 100/100, phantom 40/40, 35.06 s vs 63.2 s for the rule-based controller; yoo2025: simulation 86.9 % with vessel randomisation vs 53.7 % without, phantom 93.3 %, 89.2 %, 91.7 % (earlier controllers 83.3 % and 19.2 % in test I) (S7b evidence)",
   "sim_model": "SOFA vessel and guidewire simulation, one planar map with four targets (cho2022); randomised vessel trees every episode (yoo2025)",
   "has_sim_model": true,
   "sim2real": "yes",
   "sim2real_detail": "yes: both papers train in SOFA and run on the physical bench (cho2022 40/40; yoo2025 93.3 %, 89.2 %, 91.7 %); full read by S7b agent, abstract/figures re-checked here",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "photo",
    "source": "cho2022_sim Fig. 8 (guidewire controller, controller box, camera, phantom), IROS 2022, doi:10.1109/IROS47612.2022.9982168",
    "source_url": "https://doi.org/10.1109/IROS47612.2022.9982168",
    "licence": "publisher copyright",
    "credit": "Cho et al., 2022 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (2022), Fig. 8. publisher copyright.",
    "edits": "native extract (878x878); cropped to the bench; no erasing; not upscaled",
    "file": null
   },
   "pictures": [],
   "sources": [
    {
     "key": "cho2022_sim",
     "doi": "10.1109/iros47612.2022.9982168",
     "url": null,
     "title": "Sim-to-Real Transfer of Image-Based Autonomous Guidewire Navigation Trained by Deep Deterministic Policy Gradient with Behavior Cloning for Fast Learning",
     "year": 2022,
     "venue": "2022 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS)"
    },
    {
     "key": "yoo2025_robust",
     "doi": "10.1109/icra55743.2025.11127741",
     "url": null,
     "title": "A Robust Deep Reinforcement Learning Framework for Image-Based Autonomous Guidewire Navigation",
     "year": 2025,
     "venue": "2025 IEEE International Conference on Robotics and Automation (ICRA)"
    }
   ],
   "read_level": "partial",
   "read_level_detail": "partial (cho2022, yoo2025 text); S7b evidence",
   "notes": "Jaesoon Choi is listed with LN Robotics in yoo2025, the maker of the commercial AVIAR (A4 scope); the bench driver may share hardware with AVIAR but the papers do not say so.",
   "maintainers_own": false,
   "found_by": "academic"
  },
  {
   "schema_version": 1,
   "id": "tianjin_song2023",
   "name": "Tianjin MR-fluid",
   "full_name": "Tianjin master-slave interventional robot with MR-fluid passive haptic interface (catheter + guidewire simultaneously)",
   "group": "Tianjin University of Technology, Tianjin Key Laboratory for Control Theory and Applications (Yu Song, Yu Tian, Lin Li) with South China Agricultural University (Xuanchun Yin); Song Yu previously at Kagawa",
   "group_short": "Tianjin U. Tech.",
   "family": "academic",
   "category": "academic",
   "first_year": 2018,
   "latest_year": 2025,
   "versions": "song2018_performance (Biomed Microdevices 2018, Kagawa-era catheter operating system with haptics) -> song2023_masterslave (Sensors 2023) -> song2025_passive (MBEC 2025, passive haptic interface, abstract not read)",
   "target_anatomy": "1:1 in vitro vessel model with circulating pump (song2023_masterslave Sec. 4.3, Figs. 17-18)",
   "devices": [
    "guidewire",
    "catheter"
   ],
   "devices_driven": "catheter and guidewire navigated simultaneously",
   "n_dof": 3,
   "n_dof_detail": "3 (catheter axial + rotation, guidewire axial) (song2023 Sec. 3.2.1)",
   "translation_mechanism": "other",
   "translation_detail": "friction-roller + clamp hybrid: catheter clamped by a solenoid gripper and pushed by a stepper-driven slide (clamp + stage); guidewire between an active and an electromagnet-pressed driven friction wheel on a stepper; a solenoid guidewire-support clamp holds the wire while the catheter advances (Sec. 3.2.1-3.2.2, Figs. 11-12)",
   "rotation_mechanism": "rotating-clamp",
   "rotation_detail": "catheter only: the clamps of the catheter unit grip and a stepper motor rotates them (Sec. 3.2.2); guidewire not rotated",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "catheter resistance: the gripper floats between four force sensors and touches them under load (Sec. 3.2.1); reflected to the MRF master",
   "haptics_leader": "MRF passive haptic interface with a rigid catheter as handle: axial motion read by a Hall encoder through a removable friction wheel, rotation through a rotating tube with encoder; the force-feedback friction wheel is braked by MR fluid (Sec. 3.1)",
   "imaging_compat": "N.R.",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "bench: 1000 mm deliveries at 5-30 mm/s, 10 repeats per speed (Sec. 4.2, Fig. 15); phantom: surgeon at the master in an isolated room driving catheter and guidewire through a 1:1 in vitro model with circulating pump (Sec. 4.3, Figs. 17-18)",
   "key_numbers": "catheter axial delivery error mean 0.95 mm, max < 2.0 mm; guidewire mean 1 mm, max < 2.0 mm over 1000 mm at 5-30 mm/s (Sec. 4.2)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "cleared",
    "grade": "C",
    "kind": "photo",
    "source": "song2023_masterslave Fig. 11(b) (developed slave equipment), Sensors 2023, image https://mdpi-res.com/sensors/sensors-23-03584/article_deploy/html/images/sensors-23-03584-g011.png",
    "source_url": "https://doi.org/10.3390/s23073584",
    "licence": "CC BY 4.0",
    "credit": "Song et al., Sensors (2023), Fig. 11(b). CC BY 4.0.",
    "edits": "MDPI web image (1657x1196); cropped to panel (b); not upscaled; white dashed module boxes and labels on the robot left in place",
    "file": "pictures/tianjin_song2023.jpg"
   },
   "pictures": [
    {
     "id": "tianjin_song2023_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Master manipulator at the console and slave robot at the 1:1 EVE model",
     "source_key": "song2025_passive",
     "source": "Song et al., Medical &amp; Biological Engineering &amp; Computing (2025), Fig. 23, p. 12",
     "source_url": "https://doi.org/10.1007/s11517-025-03374-2",
     "where": "Fig. 23, p. 12",
     "licence": "publisher copyright"
    },
    {
     "id": "tianjin_song2023_02",
     "status": "cleared",
     "file": "pictures/extra/tianjin_song2023_02.jpg",
     "thumb": "pictures/thumbs/tianjin_song2023_02.jpg",
     "kind": "setup",
     "caption": "Master manipulator, controller boards and slave manipulator with EVE model",
     "source_key": "song2023_masterslave",
     "source": "Song et al., Sensors (2023), Fig. 17 (left part) (MDPI HTML figure g017)",
     "source_url": "https://doi.org/10.3390/s23073584",
     "where": "Fig. 17 (left part) (MDPI HTML figure g017)",
     "licence": "CC BY 4.0"
    },
    {
     "id": "tianjin_song2023_03",
     "status": "cleared",
     "file": "pictures/extra/tianjin_song2023_03.jpg",
     "thumb": "pictures/thumbs/tianjin_song2023_03.jpg",
     "kind": "leader",
     "caption": "Master manipulator coupled to force sensors for calibration",
     "source_key": "song2023_masterslave",
     "source": "Song et al., Sensors (2023), Fig. 13 (MDPI HTML figure g013)",
     "source_url": "https://doi.org/10.3390/s23073584",
     "where": "Fig. 13 (MDPI HTML figure g013)",
     "licence": "CC BY 4.0"
    },
    {
     "id": "tianjin_song2023_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Passive haptic master: rigid catheter, axial and radial haptic devices",
     "source_key": "song2025_passive",
     "source": "Song et al., Medical &amp; Biological Engineering &amp; Computing (2025), Fig. 3, p. 4",
     "source_url": "https://doi.org/10.1007/s11517-025-03374-2",
     "where": "Fig. 3, p. 4",
     "licence": "publisher copyright"
    },
    {
     "id": "tianjin_song2023_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD of the slave robot with catheter and guidewire manipulators",
     "source_key": "song2025_passive",
     "source": "Song et al., Medical &amp; Biological Engineering &amp; Computing (2025), Fig. 19, p. 11",
     "source_url": "https://doi.org/10.1007/s11517-025-03374-2",
     "where": "Fig. 19, p. 11",
     "licence": "publisher copyright"
    },
    {
     "id": "tianjin_song2023_06",
     "status": "cleared",
     "file": "pictures/extra/tianjin_song2023_06.jpg",
     "thumb": "pictures/thumbs/tianjin_song2023_06.jpg",
     "kind": "leader",
     "caption": "Prototype of the MR-fluid master manipulator",
     "source_key": "song2023_masterslave",
     "source": "Song et al., Sensors (2023), Fig. 3(b) (MDPI HTML figure g003)",
     "source_url": "https://doi.org/10.3390/s23073584",
     "where": "Fig. 3(b) (MDPI HTML figure g003)",
     "licence": "CC BY 4.0"
    },
    {
     "id": "tianjin_song2023_07",
     "status": "cleared",
     "file": "pictures/extra/tianjin_song2023_07.jpg",
     "thumb": "pictures/thumbs/tianjin_song2023_07.jpg",
     "kind": "render",
     "caption": "CAD of the slave: friction wheels, electromagnet and guidewire clamp",
     "source_key": "song2023_masterslave",
     "source": "Song et al., Sensors (2023), Fig. 11(a) (MDPI HTML figure g011)",
     "source_url": "https://doi.org/10.3390/s23073584",
     "where": "Fig. 11(a) (MDPI HTML figure g011)",
     "licence": "CC BY 4.0"
    },
    {
     "id": "tianjin_song2023_08",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Axial haptic device with force sensor and rigid catheters on the bench",
     "source_key": "song2025_passive",
     "source": "Song et al., Medical &amp; Biological Engineering &amp; Computing (2025), Fig. 15, p. 9",
     "source_url": "https://doi.org/10.1007/s11517-025-03374-2",
     "where": "Fig. 15, p. 9",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "song2023_masterslave",
     "doi": "10.3390/s23073584",
     "url": null,
     "title": "A Novel Master–Slave Interventional Surgery Robot with Force Feedback and Collaborative Operation",
     "year": 2023,
     "venue": "Sensors"
    },
    {
     "key": "song2018_performance",
     "doi": "10.1007/s10544-018-0294-4",
     "url": null,
     "title": "Performance evaluation of a robot-assisted catheter operating system with haptic feedback",
     "year": 2018,
     "venue": "Biomedical Microdevices"
    },
    {
     "key": "song2025_passive",
     "doi": "10.1007/s11517-025-03374-2",
     "url": null,
     "title": "Passive haptic interface for robot-assisted endovascular catheterization",
     "year": 2025,
     "venue": "Medical &amp; Biological Engineering &amp; Computing"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (song2023_masterslave, ); abstract (song2018_performance, song2025_passive)",
   "notes": "Mechanism details need the Sensors 2023 PDF (manual-download list). | 2026-11-08 X3: Sensors 2023 read in full; translation N.R. -> friction-roller + clamp hybrid; gallery already 8 (G2 used this paper's MDPI figures)",
   "maintainers_own": false,
   "found_by": "academic"
  },
  {
   "schema_version": 1,
   "id": "asan_choi2021",
   "name": "Asan PCI robot",
   "full_name": "Asan Medical Center modular bi-motional roller-cartridge PCI robot",
   "group": "Asan Medical Center, University of Ulsan College of Medicine (Jaesoon Choi; Dept. of Cardiology, Young-Hak Kim; Dept. of Convergence Medicine, Youngjin Moon) (choi2021_vascular p. 1)",
   "group_short": "Asan Med. Center",
   "family": "commercial",
   "category": "clinical-stage",
   "first_year": 2021,
   "latest_year": 2021,
   "versions": "choi2021_vascular (Biosensors 2021); 2017-18: Asan (J. Choi) EP platform driving a commercial ablation (steerable) catheter with rolling belts, leader with a 3-RRR planar manipulator (Moon 2018), ex vivo phantom (Hu 2017) (Alekseeva 2025 Table 3 row 7, Fig. 8f; Belikov 2024 Fig. 5 HU1) (alekseeva2025_design; belikov2024_evolution); 2020-21: Asan (J. Choi, Y.-H. Kim) cardiac-ablation catheter robot: dual-gripper front module inserts and rotates the catheter without slip, handle module turns the bending knob, Jacobian updated from two position sensors on the catheter (Lee 2021 J. Mech. Robot. 13, doi:10.1115/1.4048224) (Belikov 2024 Fig. 5 LE) (lee2021_design; belikov2024_evolution); 2021: deep RL (Rainbow) guidewire navigation trained and tested on the physical 2-D and 3-D coronary phantoms with an Asan robotic module whose opposed roller pair advances the wire and whose vertical roller shift rotates it, step 0.4 mm or 33 deg (Kweon 2021 IEEE Access; Konda 2025 control row 33); real-world training, not sim-to-real (kweon2021_deep; konda2025_robotically)",
   "target_anatomy": "coronary (PCI)",
   "devices": [
    "guidewire",
    "catheter",
    "therapeutic-device"
   ],
   "devices_driven": "three modules drive a guiding catheter, a guidewire and a balloon catheter (Sec. 2.1.2, p. 3), 3 devices at once; the clamping also fits guide extensions and IVUS catheters (p. 2); bench devices 5 F catheter, 0.014-in guidewire, 3.5 x 15 mm balloon (p. 10); in vivo only the guidewire was robot-driven (p. 13-16)",
   "n_dof": 8,
   "n_dof_detail": "8 by our sum (paper gives no total): guiding-catheter and guidewire modules 3-DOF each (clamp, translate, rotate), balloon module 2-DOF (choi2021_vascular Sec. 2.1.2, p. 3)",
   "translation_mechanism": "friction-roller",
   "translation_detail": "friction-roller (tightly pressed roller pairs, 20 mm rollers driven through bevel gears) (choi2021_vascular Sec. 2.1.1, p. 2-3)",
   "rotation_mechanism": "rotating-clamp",
   "rotation_detail": "Roller pair rubs the device: a motor, bevel gear and ball screw raise the cartridge frame; limited range of about 900-1800 degrees from a 25 mm vertical displacement (Sec. 2.3.2, p. 7); clamping by motor, timing belt and bidirectional ball screw (p. 4)",
   "device_range": "accommodates instruments of various sizes via the active clamping mechanism; rotation range about 900-1800 degrees per cartridge stroke (p. 7); translation stroke and speeds N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "none: no force sensor; the haptic cue is a virtual wall near the cartridge rotation limit, computed from cartridge position (choi2021_vascular Discussion, p. 17)",
   "haptics_leader": "master: 3-RRR planar parallel mechanism + linear actuator ('clutch-like trigger') + spherical wrist mechanism, called a 6-DOF mechanism (Sec. 2.1.3, p. 4-5; p. 17), Maxon DC motors; force feedback used only as a virtual wall",
   "imaging_compat": "real-time fluoroscopy on the console monitors; physician behind radiation-shielded glass (choi2021_vascular p. 5, Fig. 17b)",
   "sterility": "roller cartridge designed as a disposable part (p. 4); sterile drapes and detachable sterilised rollers form the sterile interface, no closed housing (p. 15, 17)",
   "highest_validation": "human",
   "validation_detail": "bench: 20 cartridge-gap trials, 10 repetitions per translation length and per 360-degree rotation; phantom: EVE silicone model, trial count N.R.; animal: one 60 kg pig, robot-driven guidewire into the RCA; clinical: 2 patients (coronary angiography), robot-driven guidewire to the LAD and the RCA, both technically successful; MFDS approval 20190064902 (choi2021_vascular p. 9-16)",
   "key_numbers": "translation mean error: guiding catheter -0.93 to 0.75 mm, guidewire 0.11-0.86 mm, balloon 0.07-0.57 mm (Table 1); rotation error at 360 degrees: guiding catheter 3.29 +- 5.48, guidewire 1.93 +- 2.50 degrees (Table 2) (choi2021_vascular)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "cleared",
    "grade": "B",
    "kind": "photo",
    "source": "choi2021_vascular Fig. 12 (phantom setup for PCI), Biosensors 2021, image https://mdpi-res.com/biosensors/biosensors-11-00329/article_deploy/html/images/biosensors-11-00329-g012.png",
    "source_url": "https://doi.org/10.3390/bios11090329",
    "licence": "CC BY 4.0",
    "credit": "Choi et al., Biosensors (2021), Fig. 12. CC BY 4.0.",
    "edits": "MDPI web images (2815x1631, 3426x1310); main cropped, one leader line + its dot over the wall/pole and a text fragment at the edge removed (OpenCV Telea)",
    "file": "pictures/asan_choi2021.jpg"
   },
   "pictures": [
    {
     "id": "asan_choi2021_01",
     "status": "cleared",
     "file": "pictures/extra/asan_choi2021_01.jpg",
     "thumb": "pictures/thumbs/asan_choi2021_01.jpg",
     "kind": "photo",
     "caption": "Clinical prototype: master console with haptic device and slave robot end-effector",
     "source_key": "choi2021_vascular",
     "source": "Choi et al., Biosensors (2021), Fig. 5",
     "source_url": "https://doi.org/10.3390/bios11090329",
     "where": "Fig. 5 (https://mdpi-res.com/biosensors/biosensors-11-00329/article_deploy/html/images/biosensors-11-00329-g005.png)",
     "licence": "CC BY 4.0"
    },
    {
     "id": "asan_choi2021_02",
     "status": "cleared",
     "file": "pictures/extra/asan_choi2021_02.jpg",
     "thumb": "pictures/thumbs/asan_choi2021_02.jpg",
     "kind": "in-use",
     "caption": "Clinical trial: team at the table and operator at the master console",
     "source_key": "choi2021_vascular",
     "source": "Choi et al., Biosensors (2021), Fig. 17",
     "source_url": "https://doi.org/10.3390/bios11090329",
     "where": "Fig. 17 (https://mdpi-res.com/biosensors/biosensors-11-00329/article_deploy/html/images/biosensors-11-00329-g017.png)",
     "licence": "CC BY 4.0"
    },
    {
     "id": "asan_choi2021_03",
     "status": "cleared",
     "file": "pictures/extra/asan_choi2021_03.jpg",
     "thumb": "pictures/thumbs/asan_choi2021_03.jpg",
     "kind": "setup",
     "caption": "Roller module with EM tracker and Aurora field generator beside a phantom",
     "source_key": "choi2021_vascular",
     "source": "Choi et al., Biosensors (2021), Fig. 11",
     "source_url": "https://doi.org/10.3390/bios11090329",
     "where": "Fig. 11 (https://mdpi-res.com/biosensors/biosensors-11-00329/article_deploy/html/images/biosensors-11-00329-g011.png)",
     "licence": "CC BY 4.0"
    },
    {
     "id": "asan_choi2021_04",
     "status": "cleared",
     "file": "pictures/extra/asan_choi2021_04.jpg",
     "thumb": "pictures/thumbs/asan_choi2021_04.jpg",
     "kind": "render",
     "caption": "Renderings of the slave side and master side with labelled parts",
     "source_key": "choi2021_vascular",
     "source": "Choi et al., Biosensors (2021), Fig. 1",
     "source_url": "https://doi.org/10.3390/bios11090329",
     "where": "Fig. 1 (https://mdpi-res.com/biosensors/biosensors-11-00329/article_deploy/html/images/biosensors-11-00329-g001.png)",
     "licence": "CC BY 4.0"
    },
    {
     "id": "asan_choi2021_05",
     "status": "cleared",
     "file": "pictures/extra/asan_choi2021_05.jpg",
     "thumb": "pictures/thumbs/asan_choi2021_05.jpg",
     "kind": "render",
     "caption": "CAD of the end-effector modules for guidewire, catheter and balloon",
     "source_key": "choi2021_vascular",
     "source": "Choi et al., Biosensors (2021), Fig. 2",
     "source_url": "https://doi.org/10.3390/bios11090329",
     "where": "Fig. 2 (https://mdpi-res.com/biosensors/biosensors-11-00329/article_deploy/html/images/biosensors-11-00329-g002.png)",
     "licence": "CC BY 4.0"
    },
    {
     "id": "asan_choi2021_06",
     "status": "cleared",
     "file": "pictures/extra/asan_choi2021_06.jpg",
     "thumb": "pictures/thumbs/asan_choi2021_06.jpg",
     "kind": "close-up",
     "caption": "CAD of the bi-motional roller cartridge, roller module and clamping drive",
     "source_key": "choi2021_vascular",
     "source": "Choi et al., Biosensors (2021), Fig. 3",
     "source_url": "https://doi.org/10.3390/bios11090329",
     "where": "Fig. 3 (https://mdpi-res.com/biosensors/biosensors-11-00329/article_deploy/html/images/biosensors-11-00329-g003.png)",
     "licence": "CC BY 4.0"
    },
    {
     "id": "asan_choi2021_07",
     "status": "cleared",
     "file": "pictures/extra/asan_choi2021_07.jpg",
     "thumb": "pictures/thumbs/asan_choi2021_07.jpg",
     "kind": "leader",
     "caption": "CAD of the haptic master device: spherical, linear and planar mechanisms",
     "source_key": "choi2021_vascular",
     "source": "Choi et al., Biosensors (2021), Fig. 4",
     "source_url": "https://doi.org/10.3390/bios11090329",
     "where": "Fig. 4 (https://mdpi-res.com/biosensors/biosensors-11-00329/article_deploy/html/images/biosensors-11-00329-g004.png)",
     "licence": "CC BY 4.0"
    },
    {
     "id": "asan_choi2021_08",
     "status": "cleared",
     "file": "pictures/extra/asan_choi2021_08.jpg",
     "thumb": "pictures/thumbs/asan_choi2021_08.jpg",
     "kind": "in-use",
     "caption": "Catheter steered to two targets in a vascular phantom, image sequence",
     "source_key": "choi2021_vascular",
     "source": "Choi et al., Biosensors (2021), Fig. 13",
     "source_url": "https://doi.org/10.3390/bios11090329",
     "where": "Fig. 13 (https://mdpi-res.com/biosensors/biosensors-11-00329/article_deploy/html/images/biosensors-11-00329-g013.png)",
     "licence": "CC BY 4.0"
    }
   ],
   "sources": [
    {
     "key": "choi2021_vascular",
     "doi": "10.3390/bios11090329",
     "url": null,
     "title": "A Vascular Intervention Assist Device Using Bi-Motional Roller Cartridge Structure and Clinical Evaluation",
     "year": 2021,
     "venue": "Biosensors"
    },
    {
     "key": "alekseeva2025_design",
     "doi": "10.1002/rob.22480",
     "url": null,
     "title": "The Design of Endovascular Robots for Cardiac Interventions: A Survey",
     "year": 2024,
     "venue": "Journal of Field Robotics"
    },
    {
     "key": "belikov2024_evolution",
     "doi": "10.1016/j.jestch.2024.101789",
     "url": null,
     "title": "Evolution and current state of robotic catheters for endovascular surgery: A comprehensive review",
     "year": 2024,
     "venue": "Engineering Science and Technology, an International Journal"
    },
    {
     "key": "lee2021_design",
     "doi": "10.1115/1.4048224",
     "url": null,
     "title": "Design and Control of a Robotic Steering Mechanism for Electrophysiological Catheters",
     "year": 2020,
     "venue": "Journal of Mechanisms and Robotics"
    },
    {
     "key": "kweon2021_deep",
     "doi": "10.1109/access.2021.3135277",
     "url": null,
     "title": "Deep Reinforcement Learning for Guidewire Navigation in Coronary Artery Phantom",
     "year": 2021,
     "venue": "IEEE Access"
    },
    {
     "key": "konda2025_robotically",
     "doi": "10.1126/scirobotics.adt7461",
     "url": null,
     "title": "Robotically steerable guidewires—Current trends and future directions",
     "year": 2025,
     "venue": "Science Robotics"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (choi2021_vascular)",
   "notes": "Jaesoon Choi also appears with LN Robotics (maker of commercial AVIAR, A4 scope); a precursor relationship is plausible but not stated in the abstract. | X2 2026-11-08: full text read: no mention of LN Robotics or AVIAR (no company named, no conflict of interest declared); the 'force feedback' of the abstract is a virtual wall without a force sensor; humans: 2 patients, guidewire only.",
   "maintainers_own": false,
   "found_by": "academic"
  },
  {
   "schema_version": 1,
   "id": "hanyang_crr_kim2023",
   "name": "Hanyang CRR",
   "full_name": "Hanyang/Yonsei master-slave catheter-guidewire driving systems (assembly-type 2016; coaxial controller-responder robot CRR 2023)",
   "group": "Hanyang University (Byung-Ju Yi) with Yonsei University Severance Hospital (Jong Yun Won)",
   "group_short": "Hanyang / Yonsei",
   "family": "commercial",
   "category": "clinical-stage",
   "first_year": 2016,
   "latest_year": 2024,
   "versions": "cha2016_assembly (Proc IMechE H 231(1):69-79, issue 2017, online 2016: assembly-type 4-DOF master-slave, phantom) -> Woo 2019 Appl Sci (5-DOF, haptic) and Song 2021 Appl Sci (in vivo usability), cited by kim2023 refs 14-15, not read -> 2022 its 5-DOF slave used as the guidewire/guide-catheter advancer of DGIST's ECMIS, 2 swine (hwang2022_ecmis p. 8) -> kim2023_robotassisted (JVIR 2023: 7-DOF coaxial controller-responder robot, CRR, human pilot)",
   "target_anatomy": "hepatic arteries for TACE (CRR); arterial phantom (2016)",
   "devices": [
    "guidewire",
    "microcatheter",
    "catheter"
   ],
   "devices_driven": "2016: 5 F catheter and 0.035-in guidewire (cha2016_assembly p. 75); CRR: 5 F catheter, 0.035-in guidewire, 2.2 F microcatheter (Progreat) and 0.014-in micro-guidewire (Meister), 4 devices (kim2023_robotassisted p. 1566-1567); how many move simultaneously N.R.",
   "n_dof": 7,
   "n_dof_detail": "4 (2016: insertion and rotation of catheter and guidewire, cha2016_assembly p. 71); 7 (CRR: insertion and rotation of catheter, guidewire and micro-guidewire, insertion of microcatheter, kim2023_robotassisted p. 1566)",
   "translation_mechanism": "friction-roller",
   "translation_detail": "friction-roller (2016 guidewire: active and passive roller, spring-adjusted friction) plus other: rack-and-pinion carriage that moves the catheter drive (cha2016_assembly p. 72); CRR drive type N.R. (kim2023_robotassisted)",
   "rotation_mechanism": "other",
   "rotation_detail": "2016: plastic gear trains rotate the catheter (Y-connector fixed to the rotation part) and the guidewire roller unit (cha2016_assembly p. 72); CRR N.R.",
   "device_range": "commercially available devices; 2016 catheter drive stroke 460 mm (cha2016_assembly p. 73); CRR 5 F catheter stroke 45 cm, microcatheter stroke 20 cm longer (kim2023_robotassisted p. 1568-1569)",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "Guidewire-tip contact estimated from actuator current, no dedicated sensor: under 200 mA in a straight artery, +300 mA curved, +500 mA blocked (cha2016_assembly p. 76); CRR N.R.",
   "haptics_leader": "2016: 2-DOF parallel-mechanism master (insertion, rotation) with two DC motors for haptic feedback, activate/release and catheter/guidewire mode buttons (cha2016_assembly p. 74); CRR: finger-grip handle with activate/release buttons (kim2023_robotassisted p. 1566), force feedback N.R.",
   "imaging_compat": "2016: camera over a transparent water-filled phantom; CRR: hybrid angio-CT suite (Canon INFX-8000C with Aquilion), robot mounted on the angiotable (kim2023_robotassisted p. 1567, Fig. 2a)",
   "sterility": "Device-contacting parts detach and are EtO-sterilised (all but the roller actuator part), assembly 86 s (cha2016_assembly p. 73, 77); the same for the CRR (kim2023_robotassisted citing cha2016)",
   "highest_validation": "human",
   "validation_detail": "2016: bench (10 insertion trials) and phantom (4 users x 3 trials; survey of 8) (cha2016_assembly); 2022: 2 swine as ECMIS advancer (hwang2022_ecmis); kim2023: single-centre prospective pilot, 10 HCC patients, 5 robot-assisted vs 5 conventional TACE, one operator; technical success 4/5 patients and 7/8 target vessels (one failure: 5 F catheter twisted in the telescope); no procedure-related adverse event",
   "key_numbers": "2016: max insertion error 0.63 mm, max response time 16 ms (cha2016_assembly). CRR: operator dose median 0.4 vs 53.2 uSv (P = .005); patient dose 2,167.5 vs 2,989.7 uSv (P = .311); procedure time median 56 (47-65) vs 37 (30-58) min (P = .101); 8 of 30 TACE steps robotised (abstract; Results: 8 of 22 procedural steps) (kim2023_robotassisted)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "photo",
    "source": "kim2023_robotassisted Fig. 1(a) (photo of the 7-DOF CRR responder robot), J Vasc Interv Radiol 2023;34:1565-1574, p. 4,",
    "source_url": "https://doi.org/10.1016/j.jvir.2023.06.004",
    "licence": "publisher copyright (SIR / Elsevier)",
    "credit": "Kim et al., Journal of Vascular and Interventional Radiology (2023), Fig. 1(a). publisher copyright (SIR / Elsevier).",
    "edits": "native extract (embedded 2073 x 2247, panels a-d); cropped to panel a below the three module labels; the label descenders (rows 165-178, x 215-765) replaced by mirrored backdrop rows 179-192; panel letter \"a\" (bottom left, on the backdrop) filled with a smoothed Coons patch of its border (no LaMa); none upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "hanyang_crr_kim2023_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Master console and slave robot over the patient in the angiography room",
     "source_key": "song2022_learningbased",
     "source": "Song et al., Journal of Computational Design and Engineering (2022), Fig. 4, J Comput Des Eng 2022 (academic.oup.com view-large 379575173)",
     "source_url": "https://doi.org/10.1093/jcde/qwac074",
     "where": "Fig. 4, J Comput Des Eng 2022 (academic.oup.com view-large 379575173)",
     "licence": "CC BY-NC (article page; version not stated)"
    },
    {
     "id": "hanyang_crr_kim2023_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Two-DOF joystick master device with mode and activation buttons",
     "source_key": "song2022_learningbased",
     "source": "Song et al., Journal of Computational Design and Engineering (2022), Fig. 17 (view-large 379575229)",
     "source_url": "https://doi.org/10.1093/jcde/qwac074",
     "where": "Fig. 17 (view-large 379575229)",
     "licence": "CC BY-NC (article page; version not stated)"
    },
    {
     "id": "hanyang_crr_kim2023_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Autonomous setup: slave robot, vascular phantom, RGB camera and control screens",
     "source_key": "song2022_learningbased",
     "source": "Song et al., Journal of Computational Design and Engineering (2022), Fig. 14 (view-large 379575215)",
     "source_url": "https://doi.org/10.1093/jcde/qwac074",
     "where": "Fig. 14 (view-large 379575215)",
     "licence": "CC BY-NC (article page; version not stated)"
    },
    {
     "id": "hanyang_crr_kim2023_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD of the 7-DOF responder robot: telescopic support, catheter/guidewire and microcatheter modules",
     "source_key": "kim2023_robotassisted",
     "source": "Kim et al., Journal of Vascular and Interventional Radiology (2023), Fig. 1(b), p. 4",
     "source_url": "https://doi.org/10.1016/j.jvir.2023.06.004",
     "where": "Fig. 1(b), p. 4",
     "licence": "publisher copyright"
    },
    {
     "id": "hanyang_crr_kim2023_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Controller device: finger-grip handle on a pantograph with insertion and rotation axes",
     "source_key": "kim2023_robotassisted",
     "source": "Kim et al., Journal of Vascular and Interventional Radiology (2023), Fig. 1(c-d), p. 4",
     "source_url": "https://doi.org/10.1016/j.jvir.2023.06.004",
     "where": "Fig. 1(c-d), p. 4",
     "licence": "publisher copyright"
    },
    {
     "id": "hanyang_crr_kim2023_06",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Responder robot mounted on the angiography table over the patient during TACE",
     "source_key": "kim2023_robotassisted",
     "source": "Kim et al., Journal of Vascular and Interventional Radiology (2023), Fig. 2(b), p. 5",
     "source_url": "https://doi.org/10.1016/j.jvir.2023.06.004",
     "where": "Fig. 2(b), p. 5",
     "licence": "publisher copyright"
    },
    {
     "id": "hanyang_crr_kim2023_07",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Assistants at the table and operator at the shielded controller site",
     "source_key": "kim2023_robotassisted",
     "source": "Kim et al., Journal of Vascular and Interventional Radiology (2023), Fig. 2(c-d), p. 5",
     "source_url": "https://doi.org/10.1016/j.jvir.2023.06.004",
     "where": "Fig. 2(c-d), p. 5",
     "licence": "publisher copyright"
    },
    {
     "id": "hanyang_crr_kim2023_08",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "Four-DOF slave robot of the earlier assembly-type master-slave system",
     "source_key": "song2022_learningbased",
     "source": "Song et al., Journal of Computational Design and Engineering (2022), Fig. 2 (previous main picture; OUP view-large 379575168)",
     "source_url": "https://doi.org/10.1093/jcde/qwac074",
     "where": "Fig. 2 (previous main picture; OUP view-large 379575168)",
     "licence": "CC BY-NC (per the OUP permissions link; version not stated)"
    }
   ],
   "sources": [
    {
     "key": "cha2016_assembly",
     "doi": "10.1177/0954411916679328",
     "url": null,
     "title": "An assembly-type master–slave catheter and guidewire driving system for vascular intervention",
     "year": 2016,
     "venue": "Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine"
    },
    {
     "key": "kim2023_robotassisted",
     "doi": "10.1016/j.jvir.2023.06.004",
     "url": null,
     "title": "Robot-Assisted Transarterial Chemoembolization of Hepatocellular Carcinoma Using a Coaxial Microcatheter Driving Controller-Responder Robot System: Clinical Pilot Study",
     "year": 2023,
     "venue": "Journal of Vascular and Interventional Radiology"
    },
    {
     "key": "hwang2022_ecmis",
     "doi": "10.1002/adhm.202102529",
     "url": null,
     "title": "An Electromagnetically Controllable Microrobotic Interventional System for Targeted, Real-Time Cardiovascular Intervention",
     "year": 2022,
     "venue": "Advanced Healthcare Materials"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (cha2016_assembly, kim2023_robotassisted)",
   "notes": "kim2023 cites cha2016 (ref. 13) as a previous description of the CRR system ('described in previous studies (13-15)'); the word predecessor is not used. latest_year 2024 is not supported by cha2016 or kim2023 (kim2023 is 2023). Elsevier/SAGE papers received by hand 2026-11-08. F4 2026-10-14: du2024_analyzing (full) uses the SIAT isomorphic primary-secondary robot and never mentions Hanyang; moved to row siat_haptic_duan2025. | X2 2026-11-08: raised to full text; main picture now the CRR itself (kim2023 Fig. 1a).",
   "maintainers_own": false,
   "found_by": "academic"
  },
  {
   "schema_version": 1,
   "id": "yu_complexcoronary_2023",
   "name": "Multi-device PCI",
   "full_name": "Master-slave vascular interventional robot for complex coronary lesions (collaborative multi-instrument delivery, resistance-based haptics)",
   "group": "Yanshan University (Haoyang Yu, Hongbo Wang, Jianye Niu) with co-authors Chang, Liu, Wang (yu2023_design author list; same group as yanshan_yu2023)",
   "group_short": "Yu et al.",
   "family": "academic",
   "category": "academic",
   "first_year": 2023,
   "latest_year": 2023,
   "versions": "yu2023_design (MBEC 2023)",
   "target_anatomy": "coronary complex lesions",
   "devices": [
    "other"
   ],
   "devices_driven": "multiple interventional instruments delivered collaboratively",
   "n_dof": null,
   "n_dof_detail": "N.R.",
   "translation_mechanism": "not-reported",
   "translation_detail": "N.R.",
   "rotation_mechanism": "not-reported",
   "rotation_detail": "N.R.",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "Resistance measuring mechanism for delivery resistance",
   "haptics_leader": "Active drag system generates haptic force; force-velocity mapping avoids vibration",
   "imaging_compat": "N.R.",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "Series of bench experiments (abstract); full text Sec. 3.3: human vessel model, radial artery to aortic arch, 10 testers x 10 deliveries of a catheter and a guidewire with one guidewire exchange (W4_notes.md item 4)",
   "key_numbers": "N.R.",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "photo",
    "source": "yu2023_design Fig. 16 (experiment platform: slave manipulator above, master and electronics below), MBEC 2023, doi:10.1007/s11517-023-02775-5",
    "source_url": "https://doi.org/10.1007/s11517-023-02775-5",
    "licence": "publisher copyright",
    "credit": "Yu et al., Medical &amp; Biological Engineering &amp; Computing (2023), Fig. 16. publisher copyright.",
    "edits": "native extract (960x607); main cropped to the slave",
    "file": null
   },
   "pictures": [
    {
     "id": "yu_complexcoronary_2023_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Slave manipulator delivering several instruments into a vascular phantom",
     "source_key": "yu2023_design",
     "source": "Yu et al., Medical &amp; Biological Engineering &amp; Computing (2023), Fig. 23, p. 12",
     "source_url": "https://doi.org/10.1007/s11517-023-02775-5",
     "where": "Fig. 23, p. 12",
     "licence": "publisher copyright"
    },
    {
     "id": "yu_complexcoronary_2023_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Slave manipulator and master electronics for the force-feedback test",
     "source_key": "yu2023_design",
     "source": "Yu et al., Medical &amp; Biological Engineering &amp; Computing (2023), Fig. 21, p. 12",
     "source_url": "https://doi.org/10.1007/s11517-023-02775-5",
     "where": "Fig. 21, p. 12",
     "licence": "publisher copyright"
    },
    {
     "id": "yu_complexcoronary_2023_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Resistance measurement unit with load cell, spring and clamp",
     "source_key": "yu2023_design",
     "source": "Yu et al., Medical &amp; Biological Engineering &amp; Computing (2023), Fig. 19, p. 11",
     "source_url": "https://doi.org/10.1007/s11517-023-02775-5",
     "where": "Fig. 19, p. 11",
     "licence": "publisher copyright"
    },
    {
     "id": "yu_complexcoronary_2023_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Virtual prototype of the slave with catheter and guidewire modules",
     "source_key": "yu2023_design",
     "source": "Yu et al., Medical &amp; Biological Engineering &amp; Computing (2023), Fig. 6, p. 5",
     "source_url": "https://doi.org/10.1007/s11517-023-02775-5",
     "where": "Fig. 6, p. 5",
     "licence": "publisher copyright"
    },
    {
     "id": "yu_complexcoronary_2023_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Virtual prototype of the master manipulator with two operating handles",
     "source_key": "yu2023_design",
     "source": "Yu et al., Medical &amp; Biological Engineering &amp; Computing (2023), Fig. 3, p. 3",
     "source_url": "https://doi.org/10.1007/s11517-023-02775-5",
     "where": "Fig. 3, p. 3",
     "licence": "publisher copyright"
    },
    {
     "id": "yu_complexcoronary_2023_06",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Internal structure of the master operating handle",
     "source_key": "yu2023_design",
     "source": "Yu et al., Medical &amp; Biological Engineering &amp; Computing (2023), Fig. 4, p. 4",
     "source_url": "https://doi.org/10.1007/s11517-023-02775-5",
     "where": "Fig. 4, p. 4",
     "licence": "publisher copyright"
    },
    {
     "id": "yu_complexcoronary_2023_07",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Resistance measurement mechanism of the clamping module",
     "source_key": "yu2023_design",
     "source": "Yu et al., Medical &amp; Biological Engineering &amp; Computing (2023), Fig. 13, p. 8",
     "source_url": "https://doi.org/10.1007/s11517-023-02775-5",
     "where": "Fig. 13, p. 8",
     "licence": "publisher copyright"
    },
    {
     "id": "yu_complexcoronary_2023_08",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Guidewire clamping module with roller gear train",
     "source_key": "yu2023_design",
     "source": "Yu et al., Medical &amp; Biological Engineering &amp; Computing (2023), Fig. 9, p. 6",
     "source_url": "https://doi.org/10.1007/s11517-023-02775-5",
     "where": "Fig. 9, p. 6",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "yu2023_design",
     "doi": "10.1007/s11517-023-02775-5",
     "url": null,
     "title": "Design and evaluation of vascular interventional robot system for complex coronary artery lesions",
     "year": 2023,
     "venue": "Medical &amp; Biological Engineering &amp; Computing"
    }
   ],
   "read_level": "abstract",
   "read_level_detail": "abstract (Europe PMC)",
   "notes": "Group must be identified from the PDF. | 2026-10-13 Q2: highest_validation bench -> phantom from the full text (W4_notes.md item 4); group from the full-text author list. The coordinator correction of 18:00 had been applied to yanshan_yu2023 by mistake (W6_notes.md item 9). Other cells left at abstract level so that Sec. V and VII counts stay as written (Sec. V-B names the full-text mechanism).",
   "maintainers_own": false,
   "found_by": "academic"
  },
  {
   "schema_version": 1,
   "id": "dmci_peng2023",
   "name": "DMCI",
   "full_name": "DMCI: ergonomic dual-use mechanism (master interface or compact slave with unlimited travel) for cardiovascular intervention",
   "group": "Authors Peng, Wang, Xie, Gu (affiliation not retrieved; Lixu Gu is at Shanghai Jiao Tong University, not verified from the abstract)",
   "group_short": "Peng et al.",
   "family": "academic",
   "category": "academic",
   "first_year": 2022,
   "latest_year": 2023,
   "versions": "peng2023_design (IJCARS 2023)",
   "target_anatomy": "cardiovascular intervention (bench)",
   "devices": [
    "guidewire",
    "catheter"
   ],
   "devices_driven": "interventional tool (guidewire/catheter)",
   "n_dof": null,
   "n_dof_detail": "translation + rotation, motion decoupling and coupling kinematics",
   "translation_mechanism": "not-reported",
   "translation_detail": "N.R.",
   "rotation_mechanism": "not-reported",
   "rotation_detail": "N.R.",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "N.R.",
   "haptics_leader": "DMCI doubles as the ergonomic leader interface; compared against a joystick",
   "imaging_compat": "N.R.",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "Kinematic verification and master-slave teleoperation tests; operator study vs joystick (sizes N.R.)",
   "key_numbers": "Kinematic mean errors < 1 deg and < 1 mm; master-slave errors 0.821 +/- 0.753 deg and 0.608 +/- 0.512 mm",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "A",
    "kind": "photo",
    "source": "peng2023_design Fig. 2(a) (prototype adopting DMCI), IJCARS 2023, doi:10.1007/s11548-022-02755-4",
    "source_url": "https://doi.org/10.1007/s11548-022-02755-4",
    "licence": "publisher copyright",
    "credit": "Peng et al., International Journal of Computer Assisted Radiology and Surgery (2022), Fig. 2(a). publisher copyright.",
    "edits": "native extract (2032x1154 figure); cropped to panel (a); panel letter on the white background whitened; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "dmci_peng2023_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Teleoperation setup: camera, phantom, DMCI master, gamepad and slave",
     "source_key": "peng2023_design",
     "source": "Peng et al., International Journal of Computer Assisted Radiology and Surgery (2022), Fig. 7, p. 8",
     "source_url": "https://doi.org/10.1007/s11548-022-02755-4",
     "where": "Fig. 7, p. 8",
     "licence": "publisher copyright"
    },
    {
     "id": "dmci_peng2023_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Bench evaluation of the DMCI master and slave devices",
     "source_key": "peng2023_design",
     "source": "Peng et al., International Journal of Computer Assisted Radiology and Surgery (2022), Fig. 4, p. 6",
     "source_url": "https://doi.org/10.1007/s11548-022-02755-4",
     "where": "Fig. 4, p. 6",
     "licence": "publisher copyright"
    },
    {
     "id": "dmci_peng2023_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Internal motion of the DMCI: translation, rotation and both",
     "source_key": "peng2023_design",
     "source": "Peng et al., International Journal of Computer Assisted Radiology and Surgery (2022), Fig. 3, p. 4",
     "source_url": "https://doi.org/10.1007/s11548-022-02755-4",
     "where": "Fig. 3, p. 4",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "peng2023_design",
     "doi": "10.1007/s11548-022-02755-4",
     "url": null,
     "title": "Design, development and evaluation of an ergonomically designed dual-use mechanism for robot-assisted cardiovascular intervention",
     "year": 2022,
     "venue": "International Journal of Computer Assisted Radiology and Surgery"
    }
   ],
   "read_level": "abstract",
   "read_level_detail": "abstract (Europe PMC)",
   "notes": "Group must be identified from the PDF. | 2026-10-13 coordinator: highest_validation bench -> phantom from the full text (W4_notes.md)",
   "maintainers_own": false,
   "found_by": "academic"
  },
  {
   "schema_version": 1,
   "id": "legobot_gao2026",
   "name": "LegoBot",
   "full_name": "LegoBot",
   "group": "NYU BIRO Lab (H. Su)",
   "group_short": "NYU",
   "family": "academic",
   "category": "academic",
   "first_year": 2026,
   "latest_year": 2026,
   "versions": "2026 modular 2-DOF module; 2-module (4-DOF) and 3-module (6-DOF) assemblies",
   "target_anatomy": "neurovascular (diagnostic angiography, aspiration thrombectomy); coronary and peripheral stated as applicable",
   "devices": [
    "guidewire",
    "microcatheter",
    "catheter"
   ],
   "devices_driven": "guidewire 0.014 in; 2.8 Fr/0.028 in microcatheter; 5 Fr angiographic catheter; 6 Fr aspiration catheter; 8 Fr guide catheter (five off-the-shelf devices tested for buckling load)",
   "n_dof": 6,
   "n_dof_detail": "2 per module; 4 (two modules) or 6 (three modules)",
   "translation_mechanism": "friction-roller",
   "translation_detail": "friction-roller",
   "rotation_mechanism": "rotating-clamp",
   "rotation_detail": "clamped-wheel rotation: hollow-shaft direct-drive motor (0.9 N.m peak) turns the clamped instrument; module coupler adds a second torque input via bevel gears; decoupled from translation by command compensation",
   "device_range": "0.33-3 mm (adjustable clamp)",
   "footprint_mm": "345 x 249 x 115 (three modules, Fig. 6a); module 190 mm wide",
   "mass_kg": "N.R.",
   "force_sensing": "motor side only (current, dual 17-bit encoders); no direct instrument sensing (stated limitation)",
   "haptics_leader": "none; Xbox gamepad teleoperation; haptic feedback not yet implemented",
   "imaging_compat": "N.R. (not tested)",
   "sterility": "not validated (stated future work); preloaded replaceable modules; standard Luer lock / Y-connector interfaces",
   "highest_validation": "phantom",
   "validation_detail": "benchtop: 8 Fr catheter slip test; buckling-load test with 5 devices; silicone neurovascular phantom (Type III arch): angiography with 2 modules and aspiration thrombectomy with 3 modules (clot aspirated); one demonstration each, repeat counts N.R.; one timed module exchange 1 min 50 s",
   "key_numbers": "peak insertion force 5.3 N and torque 8.4 mN.m (8 Fr) vs requirement 4.5 N / 8 mN.m; buckling load 0.1 N (0.014 in wire) to 4.3 N (8 Fr); coupler: 5 full microcatheter rotations vs ~180 deg without; 500 Hz command loop; 345x249x115 mm for 3 instruments vs 360x250x250 mm (2 instruments) of Kantu per Table I",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "cleared",
    "grade": "A",
    "kind": "photo",
    "source": "BIRO Lab, New York University (own photograph)",
    "source_url": null,
    "licence": "lab own (BIRO Lab, New York University)",
    "credit": "Photo: BIRO Lab, New York University.",
    "edits": "",
    "file": "pictures/legobot_gao2026.jpg"
   },
   "pictures": [
    {
     "id": "legobot_gao2026_01",
     "status": "cleared",
     "file": "pictures/extra/legobot_gao2026_01.jpg",
     "thumb": "pictures/thumbs/legobot_gao2026_01.jpg",
     "kind": "in-use",
     "caption": "Three-module robot driving devices into a neurovascular phantom, gamepad and GUI",
     "source_key": "gao2026_legobot",
     "source": "Gao et al., IEEE/ASME Transactions on Mechatronics (2026), lab photo IMG_4635.jpg, unannotated original of Fig. 2",
     "source_url": "https://doi.org/10.1109/TMECH.2026.3695773",
     "where": "lab photo IMG_4635.jpg, unannotated original of Fig. 2",
     "licence": "lab own (collaborator material)"
    },
    {
     "id": "legobot_gao2026_02",
     "status": "cleared",
     "file": "pictures/extra/legobot_gao2026_02.jpg",
     "thumb": "pictures/thumbs/legobot_gao2026_02.jpg",
     "kind": "close-up",
     "caption": "Single guide-catheter module with catheter loaded, gear train visible through window",
     "source_key": "gao2026_legobot",
     "source": "Gao et al., IEEE/ASME Transactions on Mechatronics (2026), lab video IMG_4651.MOV still, t = 0.67 s",
     "source_url": "https://doi.org/10.1109/TMECH.2026.3695773",
     "where": "lab video IMG_4651.MOV still, t = 0.67 s",
     "licence": "lab own (collaborator material)"
    },
    {
     "id": "legobot_gao2026_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "Guide-catheter, microcatheter and guidewire modules chained with triaxial devices loaded",
     "source_key": "gao2026_legobot",
     "source": "Gao et al., IEEE/ASME Transactions on Mechatronics (2026), Fig. 6(b), p. 6",
     "source_url": "https://doi.org/10.1109/TMECH.2026.3695773",
     "where": "Fig. 6(b), p. 6",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "legobot_gao2026_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "Top view of the stacked three-module 6-DOF prototype with dimensions",
     "source_key": "gao2026_legobot",
     "source": "Gao et al., IEEE/ASME Transactions on Mechatronics (2026), Fig. 6(a), p. 6",
     "source_url": "https://doi.org/10.1109/TMECH.2026.3695773",
     "where": "Fig. 6(a), p. 6",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "legobot_gao2026_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Two-module configuration performing diagnostic angiography in a silicone phantom",
     "source_key": "gao2026_legobot",
     "source": "Gao et al., IEEE/ASME Transactions on Mechatronics (2026), Fig. 9(a), p. 8",
     "source_url": "https://doi.org/10.1109/TMECH.2026.3695773",
     "where": "Fig. 9(a), p. 8",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "legobot_gao2026_06",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Exploded CAD of guidewire and catheter modules: lid, housing, 2-DOF cassette",
     "source_key": "gao2026_legobot",
     "source": "Gao et al., IEEE/ASME Transactions on Mechatronics (2026), Fig. 5(c), p. 5",
     "source_url": "https://doi.org/10.1109/TMECH.2026.3695773",
     "where": "Fig. 5(c), p. 5",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "legobot_gao2026_07",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Cutaway CAD of the adjustable friction-roller clamping mechanism",
     "source_key": "gao2026_legobot",
     "source": "Gao et al., IEEE/ASME Transactions on Mechatronics (2026), Fig. 4, p. 4",
     "source_url": "https://doi.org/10.1109/TMECH.2026.3695773",
     "where": "Fig. 4, p. 4",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "legobot_gao2026_08",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Guide-catheter module on bench with load cell for insertion and torque tests",
     "source_key": "gao2026_legobot",
     "source": "Gao et al., IEEE/ASME Transactions on Mechatronics (2026), Fig. 8(a)-(b), p. 7",
     "source_url": "https://doi.org/10.1109/TMECH.2026.3695773",
     "where": "Fig. 8(a)-(b), p. 7",
     "licence": "publisher copyright (IEEE)"
    }
   ],
   "sources": [
    {
     "key": "gao2026_legobot",
     "doi": "10.1109/TMECH.2026.3695773",
     "url": null,
     "title": "LegoBot: Modular, compact, device-agnostic robot for endovascular catheter and guidewire manipulation in stroke thrombectomy",
     "year": 2026,
     "venue": "IEEE/ASME Transactions on Mechatronics"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full",
   "notes": "Table I (gao2026_legobot) compares with CorPath GRX, LIBERTY, Magellan, R-One, ICL, KAIST, BIT and Kantu. Table I lists Kantu at 360x250x250 mm; the Kantu abstract says 250x350x250 mm.",
   "maintainers_own": true,
   "found_by": "academic"
  },
  {
   "schema_version": 1,
   "id": "portable_kantu2025",
   "name": "Portable robot",
   "full_name": "Portable and versatile catheter robot",
   "group": "NC State Univ. / NYU (Buckner, Su)",
   "group_short": "NC State / NYU",
   "family": "academic",
   "category": "academic",
   "first_year": 2025,
   "latest_year": 2025,
   "versions": "2025 (single version)",
   "target_anatomy": "coronary (simulated PCI in 3D-printed heart model)",
   "devices": [
    "guidewire",
    "catheter"
   ],
   "devices_driven": "guide catheter 5-9 F (5 F and 8 F tested) and guidewire 0.33-1 mm (0.36 mm and 0.89 mm tested)",
   "n_dof": 4,
   "n_dof_detail": "4 (guide catheter T+R, guidewire T+R)",
   "translation_mechanism": "other",
   "translation_detail": "other: guide catheter on 1.5 mm-pitch lead-screw platform (300 mm range); guidewire by active friction roller plus spring-loaded passive roller, range > 1200 mm",
   "rotation_mechanism": "rotating-clamp",
   "rotation_detail": "guide catheter: BLDC motor with 2:1 spur gears (360 deg); guidewire: commercial torque device on motor gear train (360 deg)",
   "device_range": "catheter 5-9 F; wire 0.33-1 mm (abstract: 1-9 F; text: clamp for 0.33-3 mm)",
   "footprint_mm": "250 x 350 x 250 (abstract; LegoBot Table I writes 360 x 250 x 250)",
   "mass_kg": "N.R. (direct-drive motor 92 g each)",
   "force_sensing": "motor current; external load cell in bench tests only",
   "haptics_leader": "none",
   "imaging_compat": "N.R.",
   "sterility": "N.R. (cartridge for sterilisation proposed in discussion)",
   "highest_validation": "phantom",
   "validation_detail": "benchtop tracking with motion capture; force/torque tests (2 catheters, 2 wires); guidewire advanced to left coronary ostium in a 3D-printed human-heart phantom with EM tracker (one demonstration)",
   "key_numbers": "peak force 5.49 N (8 F), 3.44 N (5 F), wire 0.38/0.35 N; peak torque 10.61/6.55 mN.m (8F/5F), wire 0.42/0.22 mN.m; tracking RMSE 10.3 deg and 0.31 mm; wire deviation ~6.9 deg / 0.9 mm; 90% smaller than CorPath (1780x690x1170 mm)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "cleared",
    "grade": "A",
    "kind": "photo",
    "source": "BIRO Lab, New York University (own photograph)",
    "source_url": null,
    "licence": "lab own (BIRO Lab, New York University)",
    "credit": "Photo: BIRO Lab, New York University.",
    "edits": "",
    "file": "pictures/portable_kantu2025.jpg"
   },
   "pictures": [
    {
     "id": "portable_kantu2025_01",
     "status": "cleared",
     "file": "pictures/extra/portable_kantu2025_01.jpg",
     "thumb": "pictures/thumbs/portable_kantu2025_01.jpg",
     "kind": "close-up",
     "caption": "Top module with guide-catheter clamp, rotation gear, lead screw and rails",
     "source_key": "kantu2025_portable",
     "source": "Kantu et al., IEEE/ASME Transactions on Mechatronics (2025), lab photo image50.jpg, unannotated original of Fig. 4(b)",
     "source_url": "https://doi.org/10.1109/TMECH.2025.3559911",
     "where": "lab photo image50.jpg, unannotated original of Fig. 4(b)",
     "licence": "lab own (collaborator material)"
    },
    {
     "id": "portable_kantu2025_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "Assembled 4-DoF prototype from above, top, middle and bottom modules labelled",
     "source_key": "kantu2025_portable",
     "source": "Kantu et al., IEEE/ASME Transactions on Mechatronics (2025), Fig. 4, centre photo, p. 5",
     "source_url": "https://doi.org/10.1109/TMECH.2025.3559911",
     "where": "Fig. 4, centre photo, p. 5",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "portable_kantu2025_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Guidewire module: roller insertion drive and rotation gear",
     "source_key": "kantu2025_portable",
     "source": "Kantu et al., IEEE/ASME Transactions on Mechatronics (2025), Fig. 4(c), p. 5",
     "source_url": "https://doi.org/10.1109/TMECH.2025.3559911",
     "where": "Fig. 4(c), p. 5",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "portable_kantu2025_04",
     "status": "cleared",
     "file": "pictures/extra/portable_kantu2025_04.jpg",
     "thumb": "pictures/thumbs/portable_kantu2025_04.jpg",
     "kind": "in-use",
     "caption": "Robot with top covers on feeding a guide catheter toward a heart model",
     "source_key": "kantu2025_portable",
     "source": "Kantu et al., IEEE/ASME Transactions on Mechatronics (2025), lab video poster frame image18.png, PCI lecture deck",
     "source_url": "https://doi.org/10.1109/TMECH.2025.3559911",
     "where": "lab video poster frame image18.png, PCI lecture deck",
     "licence": "lab own (collaborator material)"
    },
    {
     "id": "portable_kantu2025_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Robot deploying a guidewire into a human heart phantom with EM tracking",
     "source_key": "kantu2025_portable",
     "source": "Kantu et al., IEEE/ASME Transactions on Mechatronics (2025), Fig. 9 (top), p. 8",
     "source_url": "https://doi.org/10.1109/TMECH.2025.3559911",
     "where": "Fig. 9 (top), p. 8",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "portable_kantu2025_06",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Transparent CAD of the three-module robot with instrument paths and dimensions",
     "source_key": "kantu2025_portable",
     "source": "Kantu et al., IEEE/ASME Transactions on Mechatronics (2025), Fig. 2(a), p. 3",
     "source_url": "https://doi.org/10.1109/TMECH.2025.3559911",
     "where": "Fig. 2(a), p. 3",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "portable_kantu2025_07",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD of the guidewire drive: active and passive rollers, torquer, gears",
     "source_key": "kantu2025_portable",
     "source": "Kantu et al., IEEE/ASME Transactions on Mechatronics (2025), Fig. 2(c), p. 3",
     "source_url": "https://doi.org/10.1109/TMECH.2025.3559911",
     "where": "Fig. 2(c), p. 3",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "portable_kantu2025_08",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Guide-catheter clamp holding 5 F and 8 F catheters",
     "source_key": "kantu2025_portable",
     "source": "Kantu et al., IEEE/ASME Transactions on Mechatronics (2025), Fig. 5(a)-(b), p. 6",
     "source_url": "https://doi.org/10.1109/TMECH.2025.3559911",
     "where": "Fig. 5(a)-(b), p. 6",
     "licence": "publisher copyright (IEEE)"
    }
   ],
   "sources": [
    {
     "key": "kantu2025_portable",
     "doi": "10.1109/TMECH.2025.3559911",
     "url": null,
     "title": "Portable and Versatile Catheter Robot for Image-Guided Cardiovascular Interventions",
     "year": 2025,
     "venue": "IEEE/ASME Transactions on Mechatronics"
    },
    {
     "key": "gao2026_legobot",
     "doi": "10.1109/TMECH.2026.3695773",
     "url": null,
     "title": "LegoBot: Modular, compact, device-agnostic robot for endovascular catheter and guidewire manipulation in stroke thrombectomy",
     "year": 2026,
     "venue": "IEEE/ASME Transactions on Mechatronics"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full",
   "notes": "Coupled guidewire translation-rotation per LegoBot Table I; direct-drive 40x28 mm motors 0.15 N.m nominal / 0.33 N.m peak.",
   "maintainers_own": true,
   "found_by": "academic"
  },
  {
   "schema_version": 1,
   "id": "cathbot_kundrat2021",
   "name": "CathBot",
   "full_name": "CathBot (MR-safe platform)",
   "group": "Imperial College London, Hamlyn Centre (Dagnino, Kundrat, Yang)",
   "group_short": "Imperial",
   "family": "academic",
   "category": "academic",
   "first_year": 2018,
   "latest_year": 2023,
   "versions": "2018 haptic active constraints (Dagnino IROS); 2021 MR-safe platform (Kundrat TBME); 2023 in-vivo platform (Dagnino TBME)",
   "target_anatomy": "renal, mesenteric, iliac and carotid arteries (pig); thoracic/abdominal phantoms",
   "devices": [
    "guidewire",
    "catheter"
   ],
   "devices_driven": "one catheter and one guidewire, one at a time (not simultaneously); standard instruments, plug-and-play carriers",
   "n_dof": 6,
   "n_dof_detail": "6 per Kundrat Sec. II-C (three actuated axes per instrument); 4 per LegoBot Table I",
   "translation_mechanism": "clamp-relay",
   "translation_detail": "clamp-relay (pneumatic clamps with pneumatic stepper drivers, regripping; single stroke 20 mm per review Table IV)",
   "rotation_mechanism": "other",
   "rotation_detail": "pneumatic rotary stepper (0.3 mm and 10 deg steps)",
   "device_range": "N.R. (supplement not opened); 6 Fr sheath in the pig study",
   "footprint_mm": "520 x 140 x 120 (follower); leader 191 x 111 x 85",
   "mass_kg": "N.R.",
   "force_sensing": "none on follower; haptics rendered from image-derived tip-to-wall distance",
   "haptics_leader": "yes: handle with linear and rotary motors renders viscous force/torque; virtual fixtures slow the follower near the wall",
   "imaging_compat": "MR-Safe (ASTM F2503 class); used under fluoroscopy",
   "sterility": "single-use concept; instrument carriers detachable",
   "highest_validation": "animal",
   "validation_detail": "4 pigs, 5 target arteries, cannulation and balloon angioplasty, robot vs manual; earlier phantom user study with 7 vascular surgeons/registrars",
   "key_numbers": "success 100% both; completion 35+-14 min robot vs 15+-6 min manual (p=0.03); fluoroscopy 7+-5 vs 2+-1 min; feed 7-10 mm/s, max 30 mm/s; actuator latency 10-15 ms; clamp holding force 10.2 N (calc.)",
   "sim_model": "none found for the robot (Kundrat/Dagnino texts)",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found (Hamlyn learning-from-demonstration studies listed by search, e.g. Chi ICRA 2020, were not matched to CathBot hardware)",
   "picture": {
    "status": "not-cleared",
    "grade": "A",
    "kind": "photo",
    "source": "abdelaziz2019_versatile Fig. 1, right part (MR-safe slave robot, studio photo; embedded image 3396x1600 on p1)",
    "source_url": "https://doi.org/10.1109/iros40897.2019.8968237",
    "licence": "publisher copyright (IEEE)",
    "credit": "Abdelaziz et al., 2019 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (2019), Fig. 1. publisher copyright (IEEE).",
    "edits": "native extract; cropped to the slave robot (master device on the left excluded); no erasing; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "cathbot_kundrat2021_01",
     "status": "cleared",
     "file": "pictures/extra/cathbot_kundrat2021_01.jpg",
     "thumb": "pictures/thumbs/cathbot_kundrat2021_01.jpg",
     "kind": "in-use",
     "caption": "In-vivo porcine trial: remote manipulator on mounting arm, master in control room",
     "source_key": "dagnino2023_in",
     "source": "Dagnino et al., IEEE Transactions on Biomedical Engineering (2023), Fig. 2(A)-(D), p. 2",
     "source_url": "https://doi.org/10.1109/tbme.2022.3227734",
     "where": "Fig. 2(A)-(D), p. 2",
     "licence": "CC BY 4.0"
    },
    {
     "id": "cathbot_kundrat2021_02",
     "status": "cleared",
     "file": "pictures/extra/cathbot_kundrat2021_02.jpg",
     "thumb": "pictures/thumbs/cathbot_kundrat2021_02.jpg",
     "kind": "in-use",
     "caption": "MR-safe slave robot driving devices into an aortic phantom under fluoroscopy",
     "source_key": "kundrat2021_mr",
     "source": "Kundrat et al., IEEE Transactions on Biomedical Engineering (2021), Fig. 4(b), p. 6",
     "source_url": "https://doi.org/10.1109/tbme.2021.3065146",
     "where": "Fig. 4(b), p. 6",
     "licence": "CC BY 4.0"
    },
    {
     "id": "cathbot_kundrat2021_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Slave robot on a patient phantom inside the MRI scanner bore",
     "source_key": "abdelaziz2019_versatile",
     "source": "Abdelaziz et al., 2019 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (2019), Fig. 6(a), p. 8",
     "source_url": "https://doi.org/10.1109/iros40897.2019.8968237",
     "where": "Fig. 6(a), p. 8",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "cathbot_kundrat2021_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD close-up of pneumatic clamps and quick-release lid on the drive rails",
     "source_key": "abdelaziz2019_versatile",
     "source": "Abdelaziz et al., 2019 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (2019), Fig. 3(c), p. 3",
     "source_url": "https://doi.org/10.1109/iros40897.2019.8968237",
     "where": "Fig. 3(c), p. 3",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "cathbot_kundrat2021_05",
     "status": "cleared",
     "file": "pictures/extra/cathbot_kundrat2021_05.jpg",
     "thumb": "pictures/thumbs/cathbot_kundrat2021_05.jpg",
     "kind": "render",
     "caption": "Rendered platform: valve manifold, pneumatic tubing, master device and remote manipulator",
     "source_key": "dagnino2023_in",
     "source": "Dagnino et al., IEEE Transactions on Biomedical Engineering (2023), Fig. 1, p. 2",
     "source_url": "https://doi.org/10.1109/tbme.2022.3227734",
     "where": "Fig. 1, p. 2",
     "licence": "CC BY 4.0"
    },
    {
     "id": "cathbot_kundrat2021_06",
     "status": "cleared",
     "file": "pictures/extra/cathbot_kundrat2021_06.jpg",
     "thumb": "pictures/thumbs/cathbot_kundrat2021_06.jpg",
     "kind": "render",
     "caption": "CAD side view of catheter and guidewire drivers with quick-release lid details",
     "source_key": "kundrat2021_mr",
     "source": "Kundrat et al., IEEE Transactions on Biomedical Engineering (2021), Fig. 3(b), p. 4",
     "source_url": "https://doi.org/10.1109/tbme.2021.3065146",
     "where": "Fig. 3(b), p. 4",
     "licence": "CC BY 4.0"
    },
    {
     "id": "cathbot_kundrat2021_07",
     "status": "cleared",
     "file": "pictures/extra/cathbot_kundrat2021_07.jpg",
     "thumb": "pictures/thumbs/cathbot_kundrat2021_07.jpg",
     "kind": "leader",
     "caption": "Haptic master device with the navigation user interface in the control room",
     "source_key": "kundrat2021_mr",
     "source": "Kundrat et al., IEEE Transactions on Biomedical Engineering (2021), Fig. 4(a), p. 6",
     "source_url": "https://doi.org/10.1109/tbme.2021.3065146",
     "where": "Fig. 4(a), p. 6",
     "licence": "CC BY 4.0"
    },
    {
     "id": "cathbot_kundrat2021_08",
     "status": "cleared",
     "file": "pictures/extra/cathbot_kundrat2021_08.jpg",
     "thumb": "pictures/thumbs/cathbot_kundrat2021_08.jpg",
     "kind": "leader",
     "caption": "Master device prototype opened: belt drive, rotary and linear motors, force sensor",
     "source_key": "kundrat2021_mr",
     "source": "Kundrat et al., IEEE Transactions on Biomedical Engineering (2021), Fig. 2(b), p. 3",
     "source_url": "https://doi.org/10.1109/tbme.2021.3065146",
     "where": "Fig. 2(b), p. 3",
     "licence": "CC BY 4.0"
    }
   ],
   "sources": [
    {
     "key": "kundrat2021_mr",
     "doi": "10.1109/tbme.2021.3065146",
     "url": null,
     "title": "An MR-Safe Endovascular Robotic Platform: Design, Control, and Ex-Vivo Evaluation",
     "year": 2021,
     "venue": "IEEE Transactions on Biomedical Engineering"
    },
    {
     "key": "dagnino2023_in",
     "doi": "10.1109/tbme.2022.3227734",
     "url": null,
     "title": "In-Vivo Validation of a Novel Robotic Platform for Endovascular Intervention",
     "year": 2023,
     "venue": "IEEE Transactions on Biomedical Engineering"
    },
    {
     "key": "dagnino2018_haptic",
     "doi": "10.1109/iros.2018.8593628",
     "url": null,
     "title": "Haptic Feedback and Dynamic Active Constraints for Robot-Assisted Endovascular Catheterization",
     "year": 2018,
     "venue": "2018 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS)"
    },
    {
     "key": "pescio2025_endovascular",
     "doi": "10.1080/13645706.2025.2454237",
     "url": null,
     "title": "Endovascular robotics: technical advances and future directions",
     "year": 2025,
     "venue": "Minimally Invasive Therapy & Allied Technologies"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (kundrat2021_mr, dagnino2023_in); numbers also from",
   "notes": "LegoBot Table I lists ICL as 190x90x64 mm, clamp-based linear, 20 mm single stroke; Kundrat gives 520x140x120 mm. Row id keeps the proposed name.",
   "maintainers_own": false,
   "found_by": "academic"
  },
  {
   "schema_version": 1,
   "id": "kclneuro_sadati2025",
   "name": "KCL lead-screw",
   "full_name": "KCL lead-screw neurointervention manipulator",
   "group": "King's College London (Booth, Bergeles; Robertshaw, Jackson, Chen)",
   "group_short": "KCL",
   "family": "academic",
   "category": "academic",
   "first_year": 2025,
   "latest_year": 2026,
   "versions": "Hamlyn Symposium 2025 (Sadati, long CTR in vitro); RA-L 2026 HM-MARL; IROS 2026 world model; arXiv 2026 progressive fusion; arXiv 2607.07253 haptic leader study",
   "target_anatomy": "neurovascular: femoral artery to carotid / ICA in printed phantoms of patient CTA",
   "devices": [
    "guidewire",
    "microcatheter",
    "catheter",
    "therapeutic-device"
   ],
   "devices_driven": "0.035 in guidewire (180 cm Terumo) + 0.058 in Navien support catheter (125 cm) (towardb); jackson2026: Terumo Glidewire + Penumbra SlipCath Beacon, Penumbra Neuron MAX fixed (Sec. III-B); concentric shafts allow up to three devices (guidewires, microcatheters, stent retrievers; jackson2026 Sec. II-B)",
   "n_dof": 2,
   "n_dof_detail": "2 per carriage (translation, rotation); 4 with two devices",
   "translation_mechanism": "linear-stage+clamp",
   "translation_detail": "linear-stage+clamp (carriages on one 1 m, 2 mm-pitch lead screw; telescopic tubes between carriages against buckling)",
   "rotation_mechanism": "rotating-clamp",
   "rotation_detail": "hollow-shaft NEMA 17 stepper per carriage with drill-chuck coupling",
   "device_range": "two device sizes used; range N.R.",
   "footprint_mm": "1 m lead screw on 20x20 mm aluminium frame; other dimensions N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "ATI Mini 58 six-DOF force sensor in the guidewire carriage, proximal axial/lateral/torsional forces at 250 Hz (jackson2026 Sec. II-B, Fig. 2(c)); phantom with eight piezoresistive wall-force sensors (Fig. 3)",
   "haptics_leader": "yes in jackson2026_manual: device-mimicking dual-device handle (buttons select catheter, guidewire or both) on MyActuator RMD-L 4015 brushless motors, force reflection at 250 Hz; compared with manual, joystick and haptics-off (Sec. II-A, Fig. 1)",
   "imaging_compat": "overhead camera or mobile C-arm (Siemens Cios Spin) tracking; robot and phantom under the mobile C-arm in a mock angiography suite (jackson2026 Fig. 4(a)); no MR claim",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "in-vitro printed phantoms: 10 episodes per task (HM-MARL), 5 runs per task n=25 (world model), 5 runs per sub-task (progressive); 10 neuroradiologists x 8 runs in the haptic leader study",
   "key_numbers": "HM-MARL in vitro right ICA 100% (A12) and 70-80% (A23), left 0%; manual expert 10/10 right, 2/10 left; world model 68% vs SAC 60% in vitro; max 40 mm/s translation, 180 deg/s rotation",
   "sim_model": "yes: stEVE / SOFA BeamAdapter patient-specific CTA models (Navien and Terumo wire, E = 47 and 43 MPa) - robertshaw2026_towardb",
   "has_sim_model": true,
   "sim2real": "yes",
   "sim2real_detail": "yes: hierarchical multi-agent SAC (RA-L 2026): sim 92-100% single anatomy -> in vitro 100/70-80% right, 0% left; TD-MPC2 world model 58% sim holdout -> 68% bench; progressive fusion 90% sim -> 60/67% bench (the sim-to-real study table, robertshaw2026_towardb read full)",
   "picture": {
    "status": "cleared",
    "grade": "C",
    "kind": "photo",
    "source": "jackson2026_manual Fig. 2 (arXiv 2607.07253v1 HTML figure https://arxiv.org/html/2607.07253v1/Figs_robot_figure.png; page https://arxiv.org/html/2607.07253)",
    "source_url": "https://arxiv.org/abs/2607.07253v1",
    "licence": "CC BY 4.0",
    "credit": "Jackson et al., 2026, Fig. 2. CC BY 4.0.",
    "edits": "downloaded PNG 2888x989; cropped; letter tags a-e and their white arrows kept (arrows end on the frame and motors); not upscaled",
    "file": "pictures/kclneuro_sadati2025.jpg"
   },
   "pictures": [
    {
     "id": "kclneuro_sadati2025_01",
     "status": "cleared",
     "file": "pictures/extra/kclneuro_sadati2025_01.jpg",
     "thumb": "pictures/thumbs/kclneuro_sadati2025_01.jpg",
     "kind": "in-use",
     "caption": "Lead-screw manipulator beside a vascular phantom on the table under a mobile C-arm",
     "source_key": "robertshaw2026_safe",
     "source": "Robertshaw et al. (2026), Fig. 2, p. 3 (arXiv 2604.20151v1)",
     "source_url": "https://arxiv.org/abs/2604.20151",
     "where": "Fig. 2, p. 3 (arXiv 2604.20151v1)",
     "licence": "CC BY 4.0"
    },
    {
     "id": "kclneuro_sadati2025_02",
     "status": "cleared",
     "file": "pictures/extra/kclneuro_sadati2025_02.jpg",
     "thumb": "pictures/thumbs/kclneuro_sadati2025_02.jpg",
     "kind": "photo",
     "caption": "Long concentric-tube manipulator: lead-screw guide rail, telescopic tubes, actuation units",
     "source_key": "robertshaw2026_towardb",
     "source": "Robertshaw et al., IEEE Robotics and Automation Letters (2026), Fig. 3, p. 4 (arXiv 2602.18663v1)",
     "source_url": "https://doi.org/10.1109/lra.2026.3664661",
     "where": "Fig. 3, p. 4 (arXiv 2602.18663v1)",
     "licence": "CC BY 4.0"
    },
    {
     "id": "kclneuro_sadati2025_03",
     "status": "cleared",
     "file": "pictures/extra/kclneuro_sadati2025_03.jpg",
     "thumb": "pictures/thumbs/kclneuro_sadati2025_03.jpg",
     "kind": "in-use",
     "caption": "Robot and force-sensing phantom under a mobile C-arm in a mock angiography suite",
     "source_key": "jackson2026_manual",
     "source": "Jackson et al. (2026), Fig. 4(a), p. 4 (arXiv 2607.07253v1)",
     "source_url": "https://arxiv.org/abs/2607.07253",
     "where": "Fig. 4(a), p. 4 (arXiv 2607.07253v1)",
     "licence": "CC BY 4.0"
    },
    {
     "id": "kclneuro_sadati2025_04",
     "status": "cleared",
     "file": "pictures/extra/kclneuro_sadati2025_04.jpg",
     "thumb": "pictures/thumbs/kclneuro_sadati2025_04.jpg",
     "kind": "leader",
     "caption": "Device-mimicking haptic controller: handle, brushless motors, mode buttons",
     "source_key": "jackson2026_manual",
     "source": "Jackson et al. (2026), Fig. 1, p. 2 (arXiv 2607.07253v1)",
     "source_url": "https://arxiv.org/abs/2607.07253",
     "where": "Fig. 1, p. 2 (arXiv 2607.07253v1)",
     "licence": "CC BY 4.0"
    },
    {
     "id": "kclneuro_sadati2025_05",
     "status": "cleared",
     "file": "pictures/extra/kclneuro_sadati2025_05.jpg",
     "thumb": "pictures/thumbs/kclneuro_sadati2025_05.jpg",
     "kind": "leader",
     "caption": "Neuroradiologist teleoperating the robot from the control room",
     "source_key": "jackson2026_manual",
     "source": "Jackson et al. (2026), Fig. 4(b), p. 4 (arXiv 2607.07253v1)",
     "source_url": "https://arxiv.org/abs/2607.07253",
     "where": "Fig. 4(b), p. 4 (arXiv 2607.07253v1)",
     "licence": "CC BY 4.0"
    }
   ],
   "sources": [
    {
     "key": "robertshaw2026_towardb",
     "doi": "10.1109/lra.2026.3664661",
     "url": null,
     "title": "Toward AI Autonomous Navigation for Mechanical Thrombectomy Using Hierarchical Modular Multi-Agent Reinforcement Learning (HM-MARL)",
     "year": 2026,
     "venue": "IEEE Robotics and Automation Letters"
    },
    {
     "key": "robertshaw2026_safe",
     "doi": null,
     "url": "https://arxiv.org/abs/2604.20151",
     "title": "Toward Safe Autonomous Robotic Endovascular Interventions using World Models",
     "year": 2026,
     "venue": null
    },
    {
     "key": "robertshaw2026_progressive",
     "doi": null,
     "url": "https://arxiv.org/abs/2608.18647",
     "title": "Progressive Experience Fusion for Multi-Task World Model Control in Endovascular Navigation",
     "year": 2026,
     "venue": null
    },
    {
     "key": "jackson2026_manual",
     "doi": null,
     "url": "https://arxiv.org/abs/2607.07253",
     "title": "Manual, Joystick, or Haptic Control? An In Vitro Comparison of Navigation Strategies for Robotic Interventional Neuroradiology Procedures",
     "year": 2026,
     "venue": null
    }
   ],
   "read_level": "full",
   "read_level_detail": "full",
   "notes": "Fig. 3 caption of towardb calls the device a 'concentric tube robot' [Sadati 2025]; id kclneuro_sadati2025 is the proposed id in the sim-to-real study table. | 2026-11-08 X3: jackson2026 read in full: two NEMA 17 steppers (24 V, 600 mA, 80 Ncm), one for lead-screw translation and one for rotation; scissor-frame and telescopic-tube anti-buckling (Sec. II-B); 10 neuroradiologists (4 novices, 6 experts) x 8 navigations; wall forces stayed below 0.70 N with every controller; manual 47.7 s vs haptic-on 248.7 s, haptic-off 314.7 s, joystick 392.6 s (Abstract)",
   "maintainers_own": false,
   "found_by": "academic"
  },
  {
   "schema_version": 1,
   "id": "fau_fischer2026",
   "name": "roboEVI",
   "full_name": "roboEVI compact top-loading robot",
   "group": "FAU Erlangen-Nuernberg, SPARC lab (Mathis-Ullrich; Fischer, Karstensen)",
   "group_short": "FAU Erlangen",
   "family": "academic",
   "category": "academic",
   "first_year": 2026,
   "latest_year": 2026,
   "versions": "2026 (single)",
   "target_anatomy": "aortic arch / supra-aortic phantom (aortic root, left vertebral V2)",
   "devices": [
    "guidewire",
    "catheter"
   ],
   "devices_driven": "0.035 in guidewire or 5.2 Fr catheter, one at a time",
   "n_dof": 2,
   "n_dof_detail": "2 (translation + rotation of one instrument)",
   "translation_mechanism": "clamp-relay",
   "translation_detail": "clamp-relay (two alternating carts with pneumatic membrane grippers, threaded rod, stroke 17.5 mm per cart; leader-follower hand-over)",
   "rotation_mechanism": "rotating-clamp",
   "rotation_detail": "stepper through pinion shaft turning the gripper gear (78.4 deg per hand-over)",
   "device_range": "0.035 in wire and 5.2 Fr catheter tested; top-loading for any size",
   "footprint_mm": "176 x 137.6 x 63.2",
   "mass_kg": "N.R.",
   "force_sensing": "none (future work)",
   "haptics_leader": "none; gamepad",
   "imaging_compat": "N.R.",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "motion tracking with guidewire and catheter; pulsatile vascular phantom, 5 repeats per mode (aortic root / vertebral artery, manual vs robot)",
   "key_numbers": "relative tracking error 3.6+-2.2% (translation) and 4.1+-1.6% (rotation); phantom success 90% robot vs 100% manual; unintended branch insertions 8 vs 5; hand-over limited speed 30.4 mm/s, tested up to 19 mm/s",
   "sim_model": "none for this robot (group's stEVE/SOFA environment is separate)",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "render",
    "source": "fischer2026_compact Fig. 1 (CAD, embedded as three 2237x400 strips)",
    "source_url": "https://arxiv.org/abs/2607.11779",
    "licence": "arXiv non-exclusive distribution licence (authors' copyright)",
    "credit": "Fischer et al., 2026, Fig. 1. arXiv non-exclusive distribution licence (authors' copyright).",
    "edits": "native extract; three strips restacked; cropped; 40 px top and 25 px bottom white padding on the render's white background",
    "file": null
   },
   "pictures": [
    {
     "id": "fau_fischer2026_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Robot at the femoral access of a pulsatile vascular phantom with gamepad control",
     "source_key": "fischer2026_compact",
     "source": "Fischer et al. (2026), Fig. 2, p. 7 (arXiv 2607.11779v1)",
     "source_url": "https://arxiv.org/abs/2607.11779",
     "where": "Fig. 2, p. 7 (arXiv 2607.11779v1)",
     "licence": "arXiv non-exclusive distribution licence (authors' copyright)"
    },
    {
     "id": "fau_fischer2026_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Uncovered actuation unit with power supply, pneumatic valves and camera tracking rig",
     "source_key": "fischer2026_compact",
     "source": "Fischer et al. (2026), Fig. 3, p. 8 (arXiv 2607.11779v1)",
     "source_url": "https://arxiv.org/abs/2607.11779",
     "where": "Fig. 3, p. 8 (arXiv 2607.11779v1)",
     "licence": "arXiv non-exclusive distribution licence (authors' copyright)"
    }
   ],
   "sources": [
    {
     "key": "fischer2026_compact",
     "doi": null,
     "url": "https://arxiv.org/abs/2607.11779",
     "title": "A Compact Top-Loading Robot for Endovascular Interventions: Design, Control and Evaluation",
     "year": 2026,
     "venue": null
    }
   ],
   "read_level": "full",
   "read_level_detail": "full",
   "notes": "Fig. 1 is CAD; Fig. 3 photo shows the robot only small.",
   "maintainers_own": false,
   "found_by": "academic"
  },
  {
   "schema_version": 1,
   "id": "fraunhofer_karstensen2022",
   "name": "Wire manipulator",
   "full_name": "Karstensen guidewire manipulator (stEVE test platform)",
   "group": "Fraunhofer IPA, Project Group for Automation in Medicine and Biotechnology (T. Behr, L. Karstensen, J. Stallkamp) / KIT then FAU Erlangen-Nuernberg (F. Mathis-Ullrich)",
   "group_short": "Fraunhofer IPA",
   "family": "academic",
   "category": "academic",
   "first_year": 2019,
   "latest_year": 2025,
   "versions": "2019 CDBME test bench (behr2019_deep: 'experimental robotic manipulator' for the two guidewire DOF, 300 mm linear travel, infinite rotation, PMMA phantom, Sec. 2.4); 2020 CDBME 2D phantom bench (karstensen2020_autonomous: 'testbench manipulator ... reused', Materials and methods, Fig. 1); 2022 IJCARS (ex-vivo liver); 2025 CBM stEVE benchmark (camera and fluoroscopy benches)",
   "target_anatomy": "hepatic veins (porcine liver ex vivo); aortic arch phantoms; planar PMMA / 3D-printed 2D vessel phantoms (2019, 2020)",
   "devices": [
    "guidewire"
   ],
   "devices_driven": "one guidewire (0.035 in Terumo Radifocus angled stiff)",
   "n_dof": 2,
   "n_dof_detail": "2 (translation, continuous rotation)",
   "translation_mechanism": "linear-stage+clamp",
   "translation_detail": "linear-stage+clamp (wire fixed to a stepper on a linear rail driven by a second stepper)",
   "rotation_mechanism": "rotating-clamp",
   "rotation_detail": "stepper with the wire attached directly (infinite rotation)",
   "device_range": "N.R.",
   "footprint_mm": "N.R. (translation 300 mm)",
   "mass_kg": "N.R.",
   "force_sensing": "none",
   "haptics_leader": "none; gamepad manual control",
   "imaging_compat": "C-arm fluoroscopy with recurrent-CNN tip tracker; or overhead camera (2019-2020: camera above, light source below the phantom emulating fluoroscopy, 5 Hz; karstensen2020 Methods)",
   "sterility": "N.R.",
   "highest_validation": "ex-vivo",
   "validation_detail": "2019: 10 sim-trained DDPG runs on a PMMA bifurcation phantom (behr2019 Sec. 3); 2020: 2D glycerin-water phantom, sim-trained DDPG+HER on the bench (karstensen2020 Results); 2022: 30 targets (10 per main vein) in one ex-vivo porcine liver; 2025: 100 + 100 camera trials, 10 fluoroscopy trials on printed arch phantoms",
   "key_numbers": "2019: sim 89.6% (DDPG+HER) -> bench 7/10 (behr2019 Sec. 3); 2020: sim max 96% after 52,500 episodes, bench 'same results as in simulation', 100% with the next bifurcation as interim target (karstensen2020 Results); 2022: sim 100% (150/150) -> ex vivo 30% (9/30; wrong branch 10, entanglement 11); 2025: BasicWireNav sim 98% -> camera 97%, fluoroscopy 10/10; ArchVariety sim 90% -> camera 84%; action limits +-10 mm/s, +-6.28 rad/s at 7.5 Hz",
   "sim_model": "yes: SOFA + BeamAdapter (behr2019_deep, karstensen2020_autonomous, karstensen2022_learning), stEVE (karstensen2025_learning)",
   "has_sim_model": true,
   "sim2real": "yes",
   "sim2real_detail": "yes: behr2019_deep (full) DDPG sim 89.6% -> bench 7/10; karstensen2020_autonomous (full) DDPG+HER sim 96% -> bench same, 100% with interim targets; karstensen2022_learning (full) 100% sim -> 30% ex vivo; karstensen2025_learning (via the sim-to-real study table) 97%/84%/10-of-10",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "photo",
    "source": "karstensen2025_learning Fig. 4(a) (arXiv 2410.01956 preprint, embedded 2342x1553): guidewire manipulator in its 'guido' housing, callout 6",
    "source_url": "https://arxiv.org/abs/2410.01956",
    "licence": "arXiv non-exclusive distribution licence (authors' copyright)",
    "credit": "Karstensen et al., Computers in Biology and Medicine (2025), Fig. 4(a). arXiv non-exclusive distribution licence (authors' copyright).",
    "edits": "native extract; cropped; callouts 3 and 6 and the camera-image inset kept (the inset covers the back of the housing; removing it would invent pixels); not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "fraunhofer_karstensen2022_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Guidewire manipulator housing at a phantom under the C-arm fluoroscopy detector",
     "source_key": "karstensen2025_learning",
     "source": "Karstensen et al., Computers in Biology and Medicine (2025), Fig. 4(b), p. 7 (arXiv 2410.01956 preprint)",
     "source_url": "https://doi.org/10.1016/j.compbiomed.2025.110844",
     "where": "Fig. 4(b), p. 7 (arXiv 2410.01956 preprint)",
     "licence": "arXiv non-exclusive distribution licence (authors' copyright)"
    },
    {
     "id": "fraunhofer_karstensen2022_02",
     "status": "cleared",
     "file": "pictures/extra/fraunhofer_karstensen2022_02.jpg",
     "thumb": "pictures/thumbs/fraunhofer_karstensen2022_02.jpg",
     "kind": "in-use",
     "caption": "Ex-vivo porcine liver bench with guidewire manipulator, C-arm, pump and gamepad",
     "source_key": "karstensen2022_learning",
     "source": "Karstensen et al., International Journal of Computer Assisted Radiology and Surgery (2022), Fig. 3(c), p. 5",
     "source_url": "https://doi.org/10.1007/s11548-022-02646-8",
     "where": "Fig. 3(c), p. 5",
     "licence": "CC BY 4.0"
    },
    {
     "id": "fraunhofer_karstensen2022_03",
     "status": "cleared",
     "file": "pictures/extra/fraunhofer_karstensen2022_03.jpg",
     "thumb": "pictures/thumbs/fraunhofer_karstensen2022_03.jpg",
     "kind": "setup",
     "caption": "2020 test bench: 2-DOF manipulator housing, lit 2D phantom, camera and gamepad",
     "source_key": "karstensen2020_autonomous",
     "source": "Karstensen et al., Current Directions in Biomedical Engineering (2020), Fig. 1, p. 2",
     "source_url": "https://doi.org/10.1515/cdbme-2020-0007",
     "where": "Fig. 1, p. 2",
     "licence": "CC BY 4.0"
    },
    {
     "id": "fraunhofer_karstensen2022_04",
     "status": "cleared",
     "file": "pictures/extra/fraunhofer_karstensen2022_04.jpg",
     "thumb": "pictures/thumbs/fraunhofer_karstensen2022_04.jpg",
     "kind": "setup",
     "caption": "2020 bench: the 2-DOF guidewire manipulator in its housing beside the camera-tracked vessel phantom and a gamepad for manual control (labelled figure)",
     "source_key": "karstensen2020_autonomous",
     "source": "Karstensen et al., Current Directions in Biomedical Engineering (2020), Fig. 1, p. 2 (embedded 972x728)",
     "source_url": "https://doi.org/10.1515/cdbme-2020-0007",
     "where": "Fig. 1, p. 2 (embedded 972x728)",
     "licence": "CC BY 4.0"
    }
   ],
   "sources": [
    {
     "key": "karstensen2022_learning",
     "doi": "10.1007/s11548-022-02646-8",
     "url": null,
     "title": "Learning-based autonomous vascular guidewire navigation without human demonstration in the venous system of a porcine liver",
     "year": 2022,
     "venue": "International Journal of Computer Assisted Radiology and Surgery"
    },
    {
     "key": "karstensen2025_learning",
     "doi": "10.1016/j.compbiomed.2025.110844",
     "url": null,
     "title": "Learning-based autonomous navigation, benchmark environments and simulation framework for endovascular interventions",
     "year": 2025,
     "venue": "Computers in Biology and Medicine"
    },
    {
     "key": "karstensen2020_autonomous",
     "doi": "10.1515/cdbme-2020-0007",
     "url": null,
     "title": "Autonomous guidewire navigation in a two dimensional vascular phantom",
     "year": 2020,
     "venue": "Current Directions in Biomedical Engineering"
    },
    {
     "key": "behr2019_deep",
     "doi": "10.1515/cdbme-2019-0002",
     "url": null,
     "title": "Deep Reinforcement Learning for the Navigation of Neurovascular Catheters",
     "year": 2019,
     "venue": "Current Directions in Biomedical Engineering"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (karstensen2022_learning; behr2019_deep and karstensen2020_autonomous CDBME PDFs read 2026-11-08; karstensen2025 via the sim-to-real study table)",
   "notes": "Manipulator is small and drawn as a labelled box; no close-up photo in the paper. | 2026-11-08 X3: first_year 2022 -> 2019: behr2019 (Sec. 2.4) already ran a sim-trained DDPG on this group's 2-DOF guidewire manipulator (300 mm travel, infinite rotation), and karstensen2020 states the test-bench manipulator was reused. behr2019 is not simulation-only: 7 of 10 bench runs reached the goal (Sec. 3)",
   "maintainers_own": false,
   "found_by": "academic"
  },
  {
   "schema_version": 1,
   "id": "western_thakur2009",
   "name": "RCNS",
   "full_name": "Remote Catheter Navigation System (RCNS / MR-RCNS)",
   "group": "Western University and Robarts Research Institute (Drangova)",
   "group_short": "Western U.",
   "family": "academic",
   "category": "academic",
   "first_year": 2009,
   "latest_year": 2016,
   "versions": "2009 TBME (Thakur, fluoroscopy); 2013 TBME (Tavallaei, MR-compatible, ultrasonic motors); 2016 IJCARS (3 DOF, plunger added)",
   "target_anatomy": "cardiac / EP catheterisation; carotid model; ablation lesions (porcine, thesis)",
   "devices": [
    "catheter"
   ],
   "devices_driven": "6-7 F ablation catheters (input catheter as leader, patient catheter as follower)",
   "n_dof": 2,
   "n_dof_detail": "2 (axial, radial) in 2009 and 2013; 3 in 2016",
   "translation_mechanism": "friction-roller",
   "translation_detail": "friction-roller (urethane drive wheel(s) with spring-loaded idler rollers; two chained active rollers from 2013)",
   "rotation_mechanism": "rotating-drive-unit",
   "rotation_detail": "catheter in a slip-ring gantry rotated by a servo (2013: ultrasonic motors); chain drive",
   "device_range": "adjustable platform for different catheter gauges; 6-7 F used",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "none",
   "haptics_leader": "none; leader is a real input catheter read by optical encoders",
   "imaging_compat": "fluoroscopy (2009); MRI-compatible (2013): worst-case SNR drop 2.5%, slave 60 cm from isocentre; 2016 SNR drop < 3%, no artifacts",
   "sterility": "N.R.",
   "highest_validation": "animal",
   "validation_detail": "2009: bench plus 8 operators navigating a carotid model; 2013: bench and in-scanner tests; porcine in-vivo and ex-vivo tests reported in the Western thesis (ir.lib.uwo.ca/etd/3024), web summary only, animal count not read",
   "key_numbers": "2009: within 1 mm and 1 deg, latency under 300 ms; 2013: delay 41+-21 ms, 2+-2 deg radial, 1.0+-0.8 mm over 100 mm axial; 2016: axial error < 1 mm over 30 mm; axial grip 4 N, radial grip 18 mN.m",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "photo",
    "source": "tavallaei2016_mri3dof Fig. 2, upper half (3-DOF MR-compatible slave: handle manipulator + catheter manipulator; embedded 969x666)",
    "source_url": "https://doi.org/10.1007/s11548-015-1337-4",
    "licence": "publisher copyright (Springer; (c) CARS 2015)",
    "credit": "Tavallaei et al., International Journal of Computer Assisted Radiology and Surgery (2016), Fig. 2. publisher copyright (Springer; (c) CARS 2015).",
    "edits": "native extract; cropped to the slave half; 4 text labels and 2 arrows erased with LaMa on the plain blue backdrop (one arrow lay on the catheter manipulator's black support rod; checked at 4x zoom); not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "western_thakur2009_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "MR-compatible catheter manipulator on the patient table at the MRI bore",
     "source_key": "tavallaei2016_mri3dof",
     "source": "Tavallaei et al., International Journal of Computer Assisted Radiology and Surgery (2016), Fig. 1 (photo part), p. 2",
     "source_url": "https://doi.org/10.1007/s11548-015-1337-4",
     "where": "Fig. 1 (photo part), p. 2",
     "licence": "publisher copyright (Springer; (c) CARS 2015)"
    },
    {
     "id": "western_thakur2009_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Master user interface: catheter sensor and plunger sensor for the input catheter",
     "source_key": "tavallaei2016_mri3dof",
     "source": "Tavallaei et al., International Journal of Computer Assisted Radiology and Surgery (2016), Fig. 2, lower half, p. 2",
     "source_url": "https://doi.org/10.1007/s11548-015-1337-4",
     "where": "Fig. 2, lower half, p. 2",
     "licence": "publisher copyright (Springer; (c) CARS 2015)"
    },
    {
     "id": "western_thakur2009_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "2009 fluoroscopy version: catheter sensor, gantry catheter manipulator and phantom",
     "source_key": "thakur2009_remote",
     "source": "Thakur et al., IEEE Transactions on Biomedical Engineering (2009), Fig. 1, p. 2",
     "source_url": "https://doi.org/10.1109/TBME.2009.2017203",
     "where": "Fig. 1, p. 2",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "western_thakur2009_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "2013 MR-compatible version: master catheter sensor beside the ultrasonic-motor slave",
     "source_key": "tavallaei2013_mri",
     "source": "Tavallaei et al., IEEE Transactions on Biomedical Engineering (2013), Fig. 2, p. 2",
     "source_url": "https://doi.org/10.1109/TBME.2012.2229709",
     "where": "Fig. 2, p. 2",
     "licence": "publisher copyright (IEEE)"
    }
   ],
   "sources": [
    {
     "key": "thakur2009_remote",
     "doi": "10.1109/TBME.2009.2017203",
     "url": null,
     "title": "Design and Performance Evaluation of a Remote Catheter Navigation System",
     "year": 2009,
     "venue": "IEEE Transactions on Biomedical Engineering"
    },
    {
     "key": "tavallaei2013_mri",
     "doi": "10.1109/TBME.2012.2229709",
     "url": null,
     "title": "A Magnetic-Resonance-Imaging-Compatible Remote Catheter Navigation System",
     "year": 2013,
     "venue": "IEEE Transactions on Biomedical Engineering"
    },
    {
     "key": "tavallaei2016_mri3dof",
     "doi": "10.1007/s11548-015-1337-4",
     "url": null,
     "title": "Magnetic resonance imaging compatible remote catheter navigation system with 3 degrees of freedom",
     "year": 2016,
     "venue": "International Journal of Computer Assisted Radiology and Surgery"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (2009, 2013); abstract/web (2016, thesis)",
   "notes": "Row id uses 2009 first author; the same lab filed patents and founded Vital Biomedical Technologies (web, unverified).",
   "maintainers_own": false,
   "found_by": "academic"
  },
  {
   "schema_version": 1,
   "id": "leuven_alahmad2023",
   "name": "RACS",
   "full_name": "RACS braided-sleeve-gripper catheterisation system",
   "group": "KU Leuven (Vander Poorten, Ourak) with FBGS International",
   "group_short": "KU Leuven",
   "family": "academic",
   "category": "academic",
   "first_year": 2023,
   "latest_year": 2023,
   "versions": "2023 (single); 2015: KU Leuven teleoperated active catheter for TAVI: 2-DoF catheter driver (two DC motors: roller insertion, hollow-shaft rotation) plus pneumatic-artificial-muscle distal bending, 4-DoF haptic leader, three joystick mappings compared in an artificial aorta model (Rosa 2015 IROS) (Belikov 2024 Fig. 6 RO; Zhao 2022 Table 1 row 22) (rosa2015_intuitive; belikov2024_evolution; zhao2022_remote)",
   "target_anatomy": "cardiac ablation (beating-heart contact force); femoral-to-heart route in swine",
   "devices": [
    "guidewire",
    "catheter",
    "sheath"
   ],
   "devices_driven": "generic catheters and guidewires, one at a time (8 Fr ablation catheter and 8 Fr sheath used)",
   "n_dof": 2,
   "n_dof_detail": "2 (translation, rotation)",
   "translation_mechanism": "clamp-relay",
   "translation_detail": "clamp-relay (pair of pneumatic braided-sleeve grippers on two linear DC servomotors, dynamic regripping, infinite stroke)",
   "rotation_mechanism": "rotating-drive-unit",
   "rotation_detail": "spur-gear ring turning the whole frame about the instrument axis (maxon EC-i 40)",
   "device_range": "N.R. (design target: generic instruments)",
   "footprint_mm": "330 x 178 x 194",
   "mass_kg": "N.R.",
   "force_sensing": "multi-core FBG fibre in the catheter (pose and tip contact force); Hall sensors on the drive",
   "haptics_leader": "none; joystick",
   "imaging_compat": "monoplane fluoroscopy; MRI N.R.",
   "sterility": "N.R.",
   "highest_validation": "animal",
   "validation_detail": "bench force-control comparison (3 controllers, 3 runs each); feasibility in one live 40 kg swine (femoral incision)",
   "key_numbers": "design targets: 40 mm/s, grip force >= 4.5 N, grip torque >= 15 N.mm; contact-force error with best controller 0.0020+-0.0119 N (12.7% of 0.2 N setpoint); the 2023 stroke is unlimited",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "photo",
    "source": "alahmad2023_force Fig. 3(C), left photo (gripping-force bench; embedded 1145x1204)",
    "source_url": "https://doi.org/10.1109/tmrb.2023.3291026",
    "licence": "publisher copyright (IEEE)",
    "credit": "Al-Ahmad et al., IEEE Transactions on Medical Robotics and Bionics (2023), Fig. 3. publisher copyright (IEEE).",
    "edits": "native extract (figure labels are a separate vector layer, embedded photos are clean); cropped; no erasing; not upscaled (a Real-ESRGAN x2 version was discarded after the no-upscale rule)",
    "file": null
   },
   "pictures": [
    {
     "id": "leuven_alahmad2023_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Robot on a jointed arm at the bedside during the porcine CathLab study",
     "source_key": "alahmad2023_force",
     "source": "Al-Ahmad et al., IEEE Transactions on Medical Robotics and Bionics (2023), Fig. 9(A), p. 10",
     "source_url": "https://doi.org/10.1109/tmrb.2023.3291026",
     "where": "Fig. 9(A), p. 10",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "leuven_alahmad2023_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Close-up of the robot over the pig with a catheter deployed",
     "source_key": "alahmad2023_force",
     "source": "Al-Ahmad et al., IEEE Transactions on Medical Robotics and Bionics (2023), Fig. 9(B), p. 10",
     "source_url": "https://doi.org/10.1109/tmrb.2023.3291026",
     "where": "Fig. 9(B), p. 10",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "leuven_alahmad2023_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Robot angled toward the femoral access with a guidewire deployed in vivo",
     "source_key": "alahmad2023_force",
     "source": "Al-Ahmad et al., IEEE Transactions on Medical Robotics and Bionics (2023), Fig. 9(C), p. 10",
     "source_url": "https://doi.org/10.1109/tmrb.2023.3291026",
     "where": "Fig. 9(C), p. 10",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "leuven_alahmad2023_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD of the complete system with enclosing frames and rotation ring",
     "source_key": "alahmad2023_force",
     "source": "Al-Ahmad et al., IEEE Transactions on Medical Robotics and Bionics (2023), Fig. 1(A), p. 3",
     "source_url": "https://doi.org/10.1109/tmrb.2023.3291026",
     "where": "Fig. 1(A), p. 3",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "leuven_alahmad2023_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD without enclosing frames: grippers, linear actuator and spur gears",
     "source_key": "alahmad2023_force",
     "source": "Al-Ahmad et al., IEEE Transactions on Medical Robotics and Bionics (2023), Fig. 1(B), p. 3",
     "source_url": "https://doi.org/10.1109/tmrb.2023.3291026",
     "where": "Fig. 1(B), p. 3",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "leuven_alahmad2023_06",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Braided-sleeve gripper clamping a catheter, pneumatic fittings visible",
     "source_key": "alahmad2023_force",
     "source": "Al-Ahmad et al., IEEE Transactions on Medical Robotics and Bionics (2023), Fig. 3(A), p. 5",
     "source_url": "https://doi.org/10.1109/tmrb.2023.3291026",
     "where": "Fig. 3(A), p. 5",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "leuven_alahmad2023_07",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Isometric CAD of the sleeve-based gripper",
     "source_key": "alahmad2023_force",
     "source": "Al-Ahmad et al., IEEE Transactions on Medical Robotics and Bionics (2023), Fig. 1(D.i), p. 3",
     "source_url": "https://doi.org/10.1109/tmrb.2023.3291026",
     "where": "Fig. 1(D.i), p. 3",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "leuven_alahmad2023_08",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Characterisation bench: robot, phantom box, motion tracker and control PC",
     "source_key": "alahmad2023_force",
     "source": "Al-Ahmad et al., IEEE Transactions on Medical Robotics and Bionics (2023), Fig. 3(E), p. 5",
     "source_url": "https://doi.org/10.1109/tmrb.2023.3291026",
     "where": "Fig. 3(E), p. 5",
     "licence": "publisher copyright (IEEE)"
    }
   ],
   "sources": [
    {
     "key": "alahmad2023_force",
     "doi": "10.1109/tmrb.2023.3291026",
     "url": null,
     "title": "Force Control With a Novel Robotic Catheterization System Based on Braided Sleeve Grippers",
     "year": 2023,
     "venue": "IEEE Transactions on Medical Robotics and Bionics"
    },
    {
     "key": "rosa2015_intuitive",
     "doi": "10.1109/iros.2015.7353734",
     "url": null,
     "title": "Intuitive teleoperation of active catheters for endovascular surgery",
     "year": 2015,
     "venue": "2015 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS)"
    },
    {
     "key": "belikov2024_evolution",
     "doi": "10.1016/j.jestch.2024.101789",
     "url": null,
     "title": "Evolution and current state of robotic catheters for endovascular surgery: A comprehensive review",
     "year": 2024,
     "venue": "Engineering Science and Technology, an International Journal"
    },
    {
     "key": "zhao2022_remote",
     "doi": "10.21037/qims-21-792",
     "url": null,
     "title": "Remote vascular interventional surgery robotics: a literature review",
     "year": 2022,
     "venue": "Quantitative Imaging in Medicine and Surgery"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full",
   "notes": "Limitation stated: large distance from the distal gripper to the sheath insertion point.",
   "maintainers_own": false,
   "found_by": "academic"
  },
  {
   "schema_version": 1,
   "id": "saer_sankaran2018",
   "name": "SAER",
   "full_name": "SAER Surgeon Augmented Endovascular Robotic system",
   "group": "Univ. of Illinois Urbana-Champaign / Univ. at Buffalo (Kesavadas, Siddiqui, Snyder)",
   "group_short": "UIUC / Buffalo",
   "family": "academic",
   "category": "academic",
   "first_year": 2018,
   "latest_year": 2020,
   "versions": "2018 TBME (sankaran2018_design); 2020 IJMRCAS force calibration of the same robot's current-based proximal force estimate by bilevel optimisation (sankaran2020_force, full)",
   "target_anatomy": "branching vascular phantoms (one mimics bovine aortic arch)",
   "devices": [
    "guidewire"
   ],
   "devices_driven": "conventional guidewire (same type on leader and follower)",
   "n_dof": 2,
   "n_dof_detail": "2 (translation, rotation, uncoupled)",
   "translation_mechanism": "friction-roller",
   "translation_detail": "friction-roller (knurled rollers)",
   "rotation_mechanism": "rotating-drive-unit",
   "rotation_detail": "motor rotating the roller box about the tool axis (slip ring)",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "none; reaction force estimated from motor current, calibrated by bilevel optimisation, checked against a load cell",
   "haptics_leader": "sensing unit with encoder-read rollers on a real tool; vibratory/audio alert above 1.5 N (no force reflection)",
   "imaging_compat": "N.R.",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "simple and complex branching phantoms; count of runs N.R.; 2020: load-cell bench with a short phantom section and guidewire navigation in a simple branching phantom with a haptic alert at the block (sankaran2020 Figs. 2, 9)",
   "key_numbers": "stop/haptic threshold 1.5 N; force estimate validated at 30 and 50 rpm (curves, no error number); 2020: guidewire feed 15.7 mm/s at 30 rpm; bias force 0.6716 N at 30 rpm; unbiased estimate vs load cell RMS error 0.22 N (30 rpm) and 0.23 N (50 rpm) (sankaran2020 Results, Fig. 8)",
   "sim_model": "dynamic model of the drive only (no vessel simulator)",
   "has_sim_model": true,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "A",
    "kind": "photo",
    "source": "sankaran2018_design Fig. 4, right panel (robot module photo; embedded 3000x895)",
    "source_url": "https://doi.org/10.1109/tbme.2018.2800639",
    "licence": "publisher copyright (IEEE)",
    "credit": "Sankaran et al., IEEE Transactions on Biomedical Engineering (2018), Fig. 4. publisher copyright (IEEE).",
    "edits": "native extract; cropped off the labelled CAD panel; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "saer_sankaran2018_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Operator at the sensing unit teleoperating the robot unit into a phantom",
     "source_key": "sankaran2018_design",
     "source": "Sankaran et al., IEEE Transactions on Biomedical Engineering (2018), Fig. 14, p. 8",
     "source_url": "https://doi.org/10.1109/tbme.2018.2800639",
     "where": "Fig. 14, p. 8",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "saer_sankaran2018_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Force validation bench: robot unit, load cell, tube, controllers and power supply",
     "source_key": "sankaran2018_design",
     "source": "Sankaran et al., IEEE Transactions on Biomedical Engineering (2018), Fig. 10, p. 6",
     "source_url": "https://doi.org/10.1109/tbme.2018.2800639",
     "where": "Fig. 10, p. 6",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "saer_sankaran2018_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD of the robot module: gear train, knurled-roller box unit, slip ring",
     "source_key": "sankaran2018_design",
     "source": "Sankaran et al., IEEE Transactions on Biomedical Engineering (2018), Fig. 4, left panel, p. 4",
     "source_url": "https://doi.org/10.1109/tbme.2018.2800639",
     "where": "Fig. 4, left panel, p. 4",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "saer_sankaran2018_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Exploded view of the robot module and its linear drive unit",
     "source_key": "sankaran2018_design",
     "source": "Sankaran et al., IEEE Transactions on Biomedical Engineering (2018), Fig. 5, p. 4",
     "source_url": "https://doi.org/10.1109/tbme.2018.2800639",
     "where": "Fig. 5, p. 4",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "saer_sankaran2018_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Sensor module CAD and the surgeon's translation and rotation holding postures",
     "source_key": "sankaran2018_design",
     "source": "Sankaran et al., IEEE Transactions on Biomedical Engineering (2018), Fig. 2(a)-(c), p. 3",
     "source_url": "https://doi.org/10.1109/tbme.2018.2800639",
     "where": "Fig. 2(a)-(c), p. 3",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "saer_sankaran2018_06",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Sensor module CAD and photo with a hand-held catheter; robot module CAD and photo",
     "source_key": "sankaran2020_force",
     "source": "Sankaran et al., The International Journal of Medical Robotics and Computer Assisted Surgery (2020), Fig. 1(A)-(B), p. 2",
     "source_url": "https://doi.org/10.1002/rcs.2045",
     "where": "Fig. 1(A)-(B), p. 2",
     "licence": "publisher copyright (Wiley)"
    }
   ],
   "sources": [
    {
     "key": "sankaran2018_design",
     "doi": "10.1109/tbme.2018.2800639",
     "url": null,
     "title": "Design and Development of Surgeon Augmented Endovascular Robotic System",
     "year": 2018,
     "venue": "IEEE Transactions on Biomedical Engineering"
    },
    {
     "key": "sankaran2020_force",
     "doi": "10.1002/rcs.2045",
     "url": null,
     "title": "Force calibration for an endovascular robotic system with proximal force measurement",
     "year": 2020,
     "venue": "The International Journal of Medical Robotics and Computer Assisted Surgery"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (partial text) (sankaran2018_design); full (sankaran2020_force, )",
   "notes": "2026-11-08 X3: ashammagari2016_image (IMECE 2016, same Kesavadas group) is NOT this robot: its autonomous aortic-arch run used a 7-DOF Robai Cyton arm feeding a guidewire into the VIST simulator, MDP policy, 30/30 trials, mean 31.23 s (Experiments and Results, Fig. 4)",
   "maintainers_own": false,
   "found_by": "academic"
  },
  {
   "schema_version": 1,
   "id": "toronto_nazari2024",
   "name": "EP-catheter robot",
   "full_name": "Master-follower EP-catheter teleoperation system (Althea II lineage)",
   "group": "Toronto Metropolitan University (Zareinia, Janabi-Sharifi)",
   "group_short": "Toronto Metropolitan",
   "family": "academic",
   "category": "academic",
   "first_year": 2024,
   "latest_year": 2024,
   "versions": "Althea II (earlier, year N.R.); 2024 grip-insert-release follower",
   "target_anatomy": "cardiac ablation catheterisation",
   "devices": [
    "catheter"
   ],
   "devices_driven": "one bidirectional steerable ablation catheter (handle, shaft, knob)",
   "n_dof": 3,
   "n_dof_detail": "3 (insertion, rotation, knob bending)",
   "translation_mechanism": "clamp-relay",
   "translation_detail": "clamp-relay (grip-insert-release with rack gears; feeder supports the shaft)",
   "rotation_mechanism": "handle-rotation",
   "rotation_detail": "DC motors turn the held handle",
   "device_range": "one ablation catheter",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "N.R. (motor characterisation)",
   "haptics_leader": "yes: master models handle, shaft and knob with reaction motors on rail (3 DOF force feedback)",
   "imaging_compat": "N.R.",
   "sterility": "N.R.",
   "highest_validation": "bench",
   "validation_detail": "open-loop path tracking: circle, infinity, spiral",
   "key_numbers": "mean Euclidean error 0.64-1.53 cm; mean absolute error 0.81-1.92 cm; UDP latency 1-2 ms",
   "sim_model": "none found (master tested earlier in a simulated environment, ref [39] of the paper)",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "render",
    "source": "nazari2024_master Fig. 3 (follower CAD: handler, feeder, linear rail; embedded 1868x695)",
    "source_url": "https://arxiv.org/abs/2407.13162",
    "licence": "arXiv non-exclusive distribution licence (authors' copyright)",
    "credit": "Nazari et al., 2024, Fig. 3. arXiv non-exclusive distribution licence (authors' copyright).",
    "edits": "native extract; cropped; 30 px white padding at the bottom; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "toronto_nazari2024_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "Follower prototype: feeder with grip-insert-release unit and catheter handler",
     "source_key": "nazari2024_master",
     "source": "Nazari et al. (2024), Fig. 10(c)-(d), p. 18 (arXiv 2407.13162v2)",
     "source_url": "https://arxiv.org/abs/2407.13162",
     "where": "Fig. 10(c)-(d), p. 18 (arXiv 2407.13162v2)",
     "licence": "arXiv non-exclusive distribution licence (authors' copyright)"
    },
    {
     "id": "toronto_nazari2024_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Master device prototype on its linear rail with handle and reaction motors",
     "source_key": "nazari2024_master",
     "source": "Nazari et al. (2024), Fig. 10(a), p. 18 (arXiv 2407.13162v2)",
     "source_url": "https://arxiv.org/abs/2407.13162",
     "where": "Fig. 10(a), p. 18 (arXiv 2407.13162v2)",
     "licence": "arXiv non-exclusive distribution licence (authors' copyright)"
    },
    {
     "id": "toronto_nazari2024_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD of the follower handler: rotation and bending motors on the catheter handle",
     "source_key": "nazari2024_master",
     "source": "Nazari et al. (2024), Fig. 4, p. 8 (arXiv 2407.13162v2)",
     "source_url": "https://arxiv.org/abs/2407.13162",
     "where": "Fig. 4, p. 8 (arXiv 2407.13162v2)",
     "licence": "arXiv non-exclusive distribution licence (authors' copyright)"
    },
    {
     "id": "toronto_nazari2024_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD of the follower feeder with grip-insert-release assembly and gear chain",
     "source_key": "nazari2024_master",
     "source": "Nazari et al. (2024), Fig. 5, p. 8 (arXiv 2407.13162v2)",
     "source_url": "https://arxiv.org/abs/2407.13162",
     "where": "Fig. 5, p. 8 (arXiv 2407.13162v2)",
     "licence": "arXiv non-exclusive distribution licence (authors' copyright)"
    },
    {
     "id": "toronto_nazari2024_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "CAD side view of the final grip-insert-release feeder mechanism",
     "source_key": "nazari2024_master",
     "source": "Nazari et al. (2024), Fig. 7(A), p. 10 (arXiv 2407.13162v2)",
     "source_url": "https://arxiv.org/abs/2407.13162",
     "where": "Fig. 7(A), p. 10 (arXiv 2407.13162v2)",
     "licence": "arXiv non-exclusive distribution licence (authors' copyright)"
    },
    {
     "id": "toronto_nazari2024_06",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "CAD of the master handle with rotational and bending reaction motors",
     "source_key": "nazari2024_master",
     "source": "Nazari et al. (2024), Fig. 2, p. 6 (arXiv 2407.13162v2)",
     "source_url": "https://arxiv.org/abs/2407.13162",
     "where": "Fig. 2, p. 6 (arXiv 2407.13162v2)",
     "licence": "arXiv non-exclusive distribution licence (authors' copyright)"
    },
    {
     "id": "toronto_nazari2024_07",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD of the initial roller-type feeder design, later replaced",
     "source_key": "nazari2024_master",
     "source": "Nazari et al. (2024), Fig. 6(A), p. 9 (arXiv 2407.13162v2)",
     "source_url": "https://arxiv.org/abs/2407.13162",
     "where": "Fig. 6(A), p. 9 (arXiv 2407.13162v2)",
     "licence": "arXiv non-exclusive distribution licence (authors' copyright)"
    }
   ],
   "sources": [
    {
     "key": "nazari2024_master",
     "doi": null,
     "url": "https://arxiv.org/abs/2407.13162",
     "title": "A Master-Follower Teleoperation System for Robotic Catheterization: Design, Characterization, and Tracking Control",
     "year": 2024,
     "venue": null
    }
   ],
   "read_level": "full",
   "read_level_detail": "full",
   "notes": "Steerable EP catheter handle driver; boundary case for the endovascular scope.",
   "maintainers_own": false,
   "found_by": "academic"
  },
  {
   "schema_version": 1,
   "id": "nebraska_mohammadi2026",
   "name": "Haptic wire robot",
   "full_name": "Haptic portable guidewire robot",
   "group": "Univ. of Nebraska Omaha / UNMC (Kamenskiy, MacTaggart)",
   "group_short": "U. Nebraska",
   "family": "academic",
   "category": "academic",
   "first_year": 2026,
   "latest_year": 2026,
   "versions": "medRxiv Feb 2026; Ann Biomed Eng 2026 (DOI 10.1007/s10439-026-04315-2)",
   "target_anatomy": "peripheral / prehospital use; bench stenosis tube",
   "devices": [
    "guidewire",
    "catheter"
   ],
   "devices_driven": "guidewire or catheter (standard tools)",
   "n_dof": 2,
   "n_dof_detail": "2 (advance/retract, axial twist)",
   "translation_mechanism": "clamp-relay",
   "translation_detail": "clamp-relay (servo-driven timing belt; gripper engaged on advance, released on retract)",
   "rotation_mechanism": "rotating-clamp",
   "rotation_detail": "front servo plus twisting gripper (rack-and-pinion)",
   "device_range": "N.R.",
   "footprint_mm": "160 x 75 x 90",
   "mass_kg": "0.4",
   "force_sensing": "servo current only",
   "haptics_leader": "current-based impedance control with virtual mass-spring-damper; autonomous mode",
   "imaging_compat": "N.R.",
   "sterility": "N.R.",
   "highest_validation": "bench",
   "validation_detail": "flexible tubing with 20-80% stenosis inserts, 160 experiments (two current thresholds, rigid and flexible inserts)",
   "key_numbers": "400 g; lesion stiffness F-score 0.83 / 0.77 / 0.95 (soft / medium / stiff); retractions rise with stenosis",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "cleared",
    "grade": "A",
    "kind": "photo",
    "source": "mohammadi2026_haptic Fig. 8(a) (Ann Biomed Eng version 10.1007/s10439-026-04315-2; embedded 1500x1917)",
    "source_url": "https://doi.org/10.1007/s10439-026-04315-2",
    "licence": "CC BY 4.0",
    "credit": "Mohammadi et al., Annals of Biomedical Engineering (2026), Fig. 8(a). CC BY 4.0.",
    "edits": "native extract; cropped inside the panel border; panel letter 'a' erased (LaMa, on wood, not touching the robot); 12 px trimmed at top-left; not upscaled",
    "file": "pictures/nebraska_mohammadi2026.jpg"
   },
   "pictures": [
    {
     "id": "nebraska_mohammadi2026_01",
     "status": "cleared",
     "file": "pictures/extra/nebraska_mohammadi2026_01.jpg",
     "thumb": "pictures/thumbs/nebraska_mohammadi2026_01.jpg",
     "kind": "in-use",
     "caption": "Robot feeding a guidewire into the modular artificial-artery testbed with stenosis",
     "source_key": "mohammadi2026_haptic",
     "source": "Mohammadi et al., Annals of Biomedical Engineering (2026), Fig. 9(b), p. 11",
     "source_url": "https://doi.org/10.1007/s10439-026-04315-2",
     "where": "Fig. 9(b), p. 11",
     "licence": "CC BY 4.0"
    },
    {
     "id": "nebraska_mohammadi2026_02",
     "status": "cleared",
     "file": "pictures/extra/nebraska_mohammadi2026_02.jpg",
     "thumb": "pictures/thumbs/nebraska_mohammadi2026_02.jpg",
     "kind": "render",
     "caption": "CAD overview: main Dynamixel servo, three miniature servos, belt and wire guide",
     "source_key": "mohammadi2026_haptic",
     "source": "Mohammadi et al., Annals of Biomedical Engineering (2026), Fig. 3(a), p. 5",
     "source_url": "https://doi.org/10.1007/s10439-026-04315-2",
     "where": "Fig. 3(a), p. 5",
     "licence": "CC BY 4.0"
    },
    {
     "id": "nebraska_mohammadi2026_03",
     "status": "cleared",
     "file": "pictures/extra/nebraska_mohammadi2026_03.jpg",
     "thumb": "pictures/thumbs/nebraska_mohammadi2026_03.jpg",
     "kind": "close-up",
     "caption": "CAD of the gripper-belt advance cycle and rack-and-pinion rotation",
     "source_key": "mohammadi2026_haptic",
     "source": "Mohammadi et al., Annals of Biomedical Engineering (2026), Fig. 2(a)-(d), p. 4",
     "source_url": "https://doi.org/10.1007/s10439-026-04315-2",
     "where": "Fig. 2(a)-(d), p. 4",
     "licence": "CC BY 4.0"
    },
    {
     "id": "nebraska_mohammadi2026_04",
     "status": "cleared",
     "file": "pictures/extra/nebraska_mohammadi2026_04.jpg",
     "thumb": "pictures/thumbs/nebraska_mohammadi2026_04.jpg",
     "kind": "render",
     "caption": "CAD of the assembled testbed rack with the robot installed",
     "source_key": "mohammadi2026_haptic",
     "source": "Mohammadi et al., Annals of Biomedical Engineering (2026), Fig. 7(c), p. 9",
     "source_url": "https://doi.org/10.1007/s10439-026-04315-2",
     "where": "Fig. 7(c), p. 9",
     "licence": "CC BY 4.0"
    }
   ],
   "sources": [
    {
     "key": "mohammadi2026_haptic",
     "doi": "10.1007/s10439-026-04315-2",
     "url": null,
     "title": "Haptic Portable Robotic Device for Automated Guidewire or Catheter Navigation in Endovascular Procedures",
     "year": 2026,
     "venue": "Annals of Biomedical Engineering"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full",
   "notes": "Autonomous rule-based controller, not learned.",
   "maintainers_own": false,
   "found_by": "academic"
  },
  {
   "schema_version": 1,
   "id": "dupont_fagogenis2019",
   "name": "Haptic-vision cath.",
   "full_name": "Autonomous intracardiac catheter (haptic vision)",
   "group": "Boston Children's Hospital / Harvard Medical School, Pediatric Cardiac Bioengineering Lab (G. Fagogenis, P. E. Dupont)",
   "group_short": "Boston Children's",
   "family": "academic",
   "category": "academic",
   "first_year": 2019,
   "latest_year": 2019,
   "versions": "2019 Sci Robot",
   "target_anatomy": "transapical aortic paravalvular leak closure (pig)",
   "devices": [
    "catheter"
   ],
   "devices_driven": "its own concentric-tube robotic catheter (three precurved superelastic tubes, OD 2.77 / 2.40 / 1.875 mm, Table 1) carrying the haptic-vision sensor; tools pass through the innermost tube (occluder on a wire inside a delivery cannula, Fig. 6)",
   "n_dof": null,
   "n_dof_detail": "N.R. as a number: the drive rotates and telescopically extends three tubes relative to each other, forming two telescoping sections (Robotic catheter design; Table 1; movie S1)",
   "translation_mechanism": "other",
   "translation_detail": "other: concentric-tube drive at the tube bases rotates and telescopically extends three precurved superelastic tubes (Robotic catheter design)",
   "rotation_mechanism": "other",
   "rotation_detail": "concentric-tube drive rotates each tube at its base (Robotic catheter design)",
   "device_range": "tube OD 1.875-2.77 mm; sensor: 8 mm silicone optical window with 2.5 mm working channel (Table 1; Haptic vision sensor design)",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "no force sensor: tissue contact is inferred from the haptic-vision image (1 mm^3 NanEye CMOS camera + LED in an 8 mm silicone window); tip force set by the contact duty cycle (Fig. 1, Fig. 7)",
   "haptics_leader": "Touch (3D Systems) six-DOF joystick for the teleoperated comparator; force feedback N.R. (Computer software design)",
   "imaging_compat": "tip camera (haptic vision) for navigation; ultrasound monitor in the OR set-up (Fig. 2B); fluoroscopy N.R.",
   "sterility": "drive system draped in plastic in the OR (Fig. 2B); valve and flush system at the inner tube's proximal end keeps air out of the lumen (Robotic catheter design)",
   "highest_validation": "animal",
   "validation_detail": "in vivo, Yorkshire swine 84.3 +- 4.7 kg with a custom leaky bioprosthetic aortic valve, transapical access: apex to annulus 5 animals / 90 autonomous trials (teleop 3 / 9, manual 3 / 13); circumnavigation 3 animals / 65 trials; to the leak 5 animals / 83 trials; occluder deployment 8/11 autonomous, 7/9 teleop, 11/13 manual (Results, In vivo experiments); ex vivo pressurized porcine heart for software testing (Fig. 5)",
   "key_numbers": "autonomous 99% (89/90) apex to annulus; 95% (79/83) to leak; 66% (43/65) for annulus following; time 39+-17 s vs 34+-29 s teleop vs 31+-27 s manual; tip-to-leak distance 3.0 +- 2.0 mm (operator registration) and 2.9 +- 1.5 mm (autonomous) (Results)",
   "sim_model": "none found (a data-replay simulator of recorded in vivo images and trajectories was used to develop the navigation software, Fig. 5; it is not a mechanics model of the robot)",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "photo",
    "source": "https://www.therobotreport.com/wp-content/uploads/2019/04/kinematicControl.jpg (lead image of https://www.therobotreport.com/robotic-catheter-brings-autonomous-navigation-into-the-human-body/; credit Pediatric Cardiac Bioengineering Lab, Boston Children's Hospital)",
    "source_url": "https://www.therobotreport.com/wp-content/uploads/2019/04/kinematicControl.jpg",
    "licence": "press image",
    "credit": "https://www.therobotreport.com/wp-content/uploads/2019/04/kinematicControl.jpg (lead image of https://www.therobotreport.com/robotic-catheter-brings-autonomous-navigation-into-the-human-body/; credit Pediatric Cardiac Bioengineering Lab, Boston Children's Hospital). Licence: press image.",
    "edits": "full-size JPEG 2048x1536; cropped; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "dupont_fagogenis2019_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Draped catheter drive system at a porcine heart, joystick and graphical interface",
     "source_key": "fagogenis2019_autonomous",
     "source": "Fagogenis et al., Science Robotics (2019), Fig. 2(B), author manuscript (PMC image nihms-1035499-f0002.jpg, 800 px)",
     "source_url": "https://doi.org/10.1126/scirobotics.aaw1977",
     "where": "Fig. 2(B), author manuscript (PMC image nihms-1035499-f0002.jpg, 800 px)",
     "licence": "publisher copyright (AAAS; NIH author manuscript PMC6693882)"
    },
    {
     "id": "dupont_fagogenis2019_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "The three pre-curved concentric tubes of the robotic catheter",
     "source_key": "fagogenis2019_autonomous",
     "source": "Fagogenis et al., Science Robotics (2019), Fig. 4(C), author manuscript (PMC image nihms-1035499-f0004.jpg, 800 px)",
     "source_url": "https://doi.org/10.1126/scirobotics.aaw1977",
     "where": "Fig. 4(C), author manuscript (PMC image nihms-1035499-f0004.jpg, 800 px)",
     "licence": "publisher copyright (AAAS; NIH author manuscript PMC6693882)"
    },
    {
     "id": "dupont_fagogenis2019_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Haptic-vision sensor at the catheter tip beside a US cent coin",
     "source_key": "fagogenis2019_autonomous",
     "source": "Fagogenis et al., Science Robotics (2019), Fig. 1(A), p. 2",
     "source_url": "https://doi.org/10.1126/scirobotics.aaw1977",
     "where": "Fig. 1(A), p. 2",
     "licence": "publisher copyright"
    },
    {
     "id": "dupont_fagogenis2019_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "Fabricated concentric-tube catheter with sensor inside a 3D-printed heart model",
     "source_key": "fagogenis2019_autonomous",
     "source": "Fagogenis et al., Science Robotics (2019), Fig. 4(B), p. 7",
     "source_url": "https://doi.org/10.1126/scirobotics.aaw1977",
     "where": "Fig. 4(B), p. 7",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "fagogenis2019_autonomous",
     "doi": "10.1126/scirobotics.aaw1977",
     "url": null,
     "title": "Autonomous robotic intracardiac catheter navigation using haptic vision",
     "year": 2019,
     "venue": "Science Robotics"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (fagogenis2019_autonomous,, hand-downloaded 2026-11-08)",
   "notes": "Tip-actuated catheter: overlaps agent A5; listed because it was named in the brief. Coordinator may drop. | 2026-11-08 X3: full text read. Correction: translation_mechanism tendon/tip-actuation -> other: concentric-tube drive (the paper builds the catheter as a concentric tube robot, no tendons); the drive sits on a passively adjustable frame on the OR table",
   "maintainers_own": false,
   "found_by": "academic"
  },
  {
   "schema_version": 1,
   "id": "corpathgrx_corindus2016",
   "name": "CorPath GRX",
   "full_name": "CorPath 200 / CorPath GRX",
   "group": "Corindus (Siemens Healthineers 2019-)",
   "group_short": "Corindus",
   "family": "commercial",
   "category": "commercial",
   "first_year": 2011,
   "latest_year": 2026,
   "versions": "CorPath 200 (FDA 510(k) K120834, 2012-07-19; used in PRECISE, weisz2013_safety, and in the RAPID peripheral trial, mahmud2016_feasibility); CorPath GRX (K160121, 2016-10-27; PVI 2018; PMDA 2018; neuro CE/TGA 2019-2020); neuro cassette",
   "target_anatomy": "coronary; peripheral; neurovascular (angiography, aneurysm coiling, carotid stenting; thrombectomy in vitro only)",
   "devices": [
    "guidewire",
    "microcatheter",
    "catheter",
    "therapeutic-device"
   ],
   "devices_driven": "GRX: guide catheter (advance 100 mm + rotate), 0.014-in guidewire, rapid-exchange balloon/stent catheter; neuro cassette: microcatheter, 0.014-in wire, coils/stents (stent/stent-retriever compatibility limited); CorPath 200: all commercial 0.014-in guidewires, rapid-exchange balloons and stent delivery systems, guide catheter positioned by hand and connected to the disposable cassette (6 F in 119, 7 F in 45 PRECISE patients) (weisz2013_safety p. 1597-1598); RAPID: 0.014-in wires and RX balloons 3-7 x 20 mm, the over-the-wire self-expanding stent delivered by hand (mahmud2016_feasibility p. 2059)",
   "n_dof": 5,
   "n_dof_detail": "5 for GRX (gao2026_legobot Table I via S8); CorPath 200: 3, insertion and rotation of the guidewire and insertion of the stent catheter (cha2016_assembly p. 70); li2024_design Table I says 2 (conflict)",
   "translation_mechanism": "friction-roller",
   "translation_detail": "friction-roller",
   "rotation_mechanism": "rotating-clamp",
   "rotation_detail": "clamped-wheel rotation of guidewire in single-use cassette (S8 csv)",
   "device_range": "N.R.",
   "footprint_mm": "N.R. (bedside arm on table rail + radiation-shielded cockpit)",
   "mass_kg": "N.R.",
   "force_sensing": "none (ren2023_critical Table IV); CorPath 200: proximal force measurement (rafiitari2014_current Table 3); no haptic feedback",
   "haptics_leader": "no: CorPath 200 radiation-shielded mobile cockpit with console joysticks or touch-screen buttons (weisz2013_safety p. 1597), 2 joysticks (mahmud2016_feasibility p. 2059); GRX control console with touch screen and three joysticks for device, guidewire and guide catheter (Corindus media-kit image Control-Console_HR.jpg)",
   "imaging_compat": "standard cath lab fluoroscopy; fluoroscopic, ECG and haemodynamic images slaved to duplicate monitors in the cockpit (weisz2013_safety p. 1597)",
   "sterility": "single-use sterile cassette on the bedside arm (weisz2013_safety; mahmud2016_feasibility, cassette attached to the sheath with a Tuohy-Borst); drape not mentioned in these papers",
   "highest_validation": "human",
   "validation_detail": "PRECISE 164 pts at 9 sites, 23 operators (CorPath 200, weisz2013_safety p. 1597); RAPID peripheral 20 pts/29 lesions, single centre (Graz), 3 operators (CorPath 200, mahmud2016_feasibility); GRX PCI 980 procedures pooled; neuro: 117-pt aneurysm study (10 sites), 214 diagnostic angiographies single centre, 6 aneurysm, 4 carotid stent, 10 angio/carotid; thrombectomy only in vitro/3D-printed models",
   "key_numbers": "PRECISE: device technical success 162/164 (98.8%), clinical success 160/164 (97.6%), 2 conversions for stent-delivery resistance, procedure time 24.4 +- 14.1 min, fluoroscopy 11.1 +- 6.2 min, operator dose 95.2% lower in the cockpit than at the table (weisz2013_safety). RAPID: device technical success, safety and clinical procedural success 100%, 3 minor access-site haematomas, operator dose not measured (mahmud2016_feasibility). Neuro aneurysm: 110/117 (94.0%) without unplanned conversion, 117.3+-47.3 min total, 2 ruptures 2 strokes (mendespereira2024_evaluation abstract). Diagnostic cerebral angiography 214 robotic vs 636 manual: no difference in times or patient dose, conversion 39/214 (18%) (hamimi2026_learning abstract). Meta-analysis 7 neuro studies/265 pts: pooled technical success 87% (95% CI 75-96) (tan2026_corpathmeta abstract). Visceral: 16/18 (88.9%) technical success (wagenpfeil2026_visceral abstract). Automated movements on vs off 49 pts: conversion 22% vs 18% (ruggiero2026_evaluation).",
   "sim_model": "none found (no public model of the robot; neuro in-vitro/3D-printed-phantom studies used the real robot: tomasello2024_modeling, kaneko2026_in, williams2025_robotic)",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found; only fixed-rule automation in the product (Rotate-on-Retract, technIQ), alnooryani2018_rotate (human, 1 patient, full) - not learned; Siemens ARPA-H award 2026-08-20 aims at autonomous remote thrombectomy (press, not a result)",
   "picture": {
    "status": "not-cleared",
    "grade": "A",
    "kind": "product-photo",
    "source": "https://web.archive.org/web/2019id_/https://www.corindus.com/assets/images/mediakit/Extended-Reach_Arm_HR.jpg (Corindus media kit page https://www.corindus.com/news-events/media-kit, Wayback snapshot 2019-12-21)",
    "source_url": "https://web.archive.org/web/2019id_/https://www.corindus.com/assets/images/mediakit/Extended-Reach_Arm_HR.jpg",
    "licence": "press image (Corindus media kit; image carries \"Copyright (c) Corindus, Inc. All rights reserved\"; credit Corindus/Siemens Healthineers in caption)",
    "credit": "https://web.archive.org/web/2019id_/https://www.corindus.com/assets/images/mediakit/Extended-Reach_Arm_HR.jpg (Corindus media kit page https://www.corindus.com/news-events/media-kit, Wayback snapshot 2019-12-21). Licence: press image (Corindus media kit; image carries \"Copyright (c) Corindus, Inc. All rights reserved\"; credit Corindus/Siemens Healthineers in caption).",
    "edits": "cropped (350,160)-(5745,2760) of 5952x3040, which also drops the copyright line at bottom right (put the credit in the caption)",
    "file": null
   },
   "pictures": [
    {
     "id": "corpathgrx_corindus2016_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Robotic drive with the single-use cassette, product close-up",
     "source_key": "web:corindus.com (Wayback)",
     "source": "corindus.com (Wayback), Corindus media kit Robotic-Drive-and-Single-use-Cassette_HR.jpg",
     "source_url": "https://web.archive.org/web/2019id_/https://www.corindus.com/assets/images/mediakit/Robotic-Drive-and-Single-use-Cassette_HR.jpg",
     "where": "Corindus media kit Robotic-Drive-and-Single-use-Cassette_HR.jpg, https://web.archive.org/web/2019id_/https://www.corindus.com/assets/images/mediakit/Robotic-Drive-and-Single-use-Cassette_HR.jpg",
     "licence": "press image"
    },
    {
     "id": "corpathgrx_corindus2016_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Operator seated at the CorPath GRX interventional cockpit with joysticks",
     "source_key": "chen2023_operating",
     "source": "Chen et al., IEEE Transactions on Medical Robotics and Bionics (2023), Fig. 8(d), p. 7",
     "source_url": "https://doi.org/10.1109/tmrb.2023.3272049",
     "where": "Fig. 8(d), p. 7",
     "licence": "publisher copyright"
    },
    {
     "id": "corpathgrx_corindus2016_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "CorPath GRX control console: touch screen and joysticks for device, guidewire and guide catheter",
     "source_key": "web:corindus.com media kit",
     "source": "corindus.com media kit, Corindus media kit Control-Console_HR.jpg (2913 x 2574; hand-downloaded, figures/raw/web/Control-Console_HR.jpg); bottom strip with the copyright line cropped",
     "source_url": null,
     "where": "Corindus media kit Control-Console_HR.jpg (2913 x 2574; hand-downloaded, figures/raw/web/Control-Console_HR.jpg); bottom strip with the copyright line cropped",
     "licence": "press image"
    },
    {
     "id": "corpathgrx_corindus2016_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "CorPath 200 in the cath lab: operator in the shielded cockpit, cassette at the table",
     "source_key": "weisz2013_safety",
     "source": "Weisz et al., Journal of the American College of Cardiology (2013), Fig. 1, p. 2",
     "source_url": "https://doi.org/10.1016/j.jacc.2012.12.045",
     "where": "Fig. 1, p. 2",
     "licence": "publisher copyright"
    },
    {
     "id": "corpathgrx_corindus2016_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "CorPath 200 layout: articulating arm, robotic drive, single-use cassette and cockpit (labelled)",
     "source_key": "mahmud2016_feasibility",
     "source": "Mahmud et al., JACC: Cardiovascular Interventions (2016), Fig. 1, p. 3",
     "source_url": "https://doi.org/10.1016/j.jcin.2016.07.002",
     "where": "Fig. 1, p. 3",
     "licence": "publisher copyright"
    },
    {
     "id": "corpathgrx_corindus2016_06",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Peripheral intervention: draped robotic drive at the leg and investigator at the cockpit",
     "source_key": "mahmud2016_feasibility",
     "source": "Mahmud et al., JACC: Cardiovascular Interventions (2016), Fig. 2(A-B), p. 4",
     "source_url": "https://doi.org/10.1016/j.jcin.2016.07.002",
     "where": "Fig. 2(A-B), p. 4",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "fda2012_k120834",
     "doi": null,
     "url": "https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfPMN/pmn.cfm?ID=K120834",
     "title": "510(k) Premarket Notification K120834: CorPath 200 System (Corindus, Inc.)",
     "year": 2012,
     "venue": null
    },
    {
     "key": "fda2016_k160121",
     "doi": null,
     "url": "https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfPMN/pmn.cfm?ID=K160121",
     "title": "510(k) Premarket Notification K160121: CorPath GRX System (Corindus, Inc.)",
     "year": 2016,
     "venue": null
    },
    {
     "key": "weisz2013_safety",
     "doi": "10.1016/j.jacc.2012.12.045",
     "url": null,
     "title": "Safety and Feasibility of Robotic Percutaneous Coronary Intervention",
     "year": 2013,
     "venue": "Journal of the American College of Cardiology"
    },
    {
     "key": "mahmud2025_robotic",
     "doi": "10.1016/j.jscai.2025.103655",
     "url": null,
     "title": "Robotic-Assisted Percutaneous Coronary Intervention: Final Results of the PRECISION and PRECISION GRX Studies",
     "year": 2025,
     "venue": "Journal of the Society for Cardiovascular Angiography & Interventions"
    },
    {
     "key": "mahmud2016_feasibility",
     "doi": "10.1016/j.jcin.2016.07.002",
     "url": null,
     "title": "Feasibility and Safety of Robotic Peripheral Vascular Interventions",
     "year": 2016,
     "venue": "JACC: Cardiovascular Interventions"
    },
    {
     "key": "mendespereira2020_first",
     "doi": "10.1136/neurintsurg-2019-015671.rep",
     "url": null,
     "title": "First-in-human, robotic-assisted neuroendovascular intervention",
     "year": 2020,
     "venue": "Journal of NeuroInterventional Surgery"
    },
    {
     "key": "mendespereira2024_evaluation",
     "doi": "10.1136/jnis-2023-020161",
     "url": null,
     "title": "Evaluation of effectiveness and safety of the CorPath GRX robotic system in endovascular embolization procedures of cerebral aneurysms",
     "year": 2023,
     "venue": "Journal of NeuroInterventional Surgery"
    },
    {
     "key": "hamimi2026_learning",
     "doi": "10.3174/ajnr.a9651",
     "url": null,
     "title": "Robotic-Assisted versus Manual Diagnostic Cerebral Angiography: Comparative Outcomes and Learning Curve in a Large Single-Institution Cohort",
     "year": 2026,
     "venue": "American Journal of Neuroradiology"
    },
    {
     "key": "tan2026_corpathmeta",
     "doi": "10.1007/s11701-026-03665-2",
     "url": null,
     "title": "Evaluating the CorPath GRX robotic system in cerebral aneurysm embolization and diagnostic angiography: a systematic review and single-arm meta-analysis",
     "year": 2026,
     "venue": "Journal of Robotic Surgery"
    },
    {
     "key": "wagenpfeil2026_visceral",
     "doi": "10.1007/s00270-025-04340-z",
     "url": null,
     "title": "Clinical Feasibility of Robotic-Assisted Endovascular Visceral Interventions",
     "year": 2026,
     "venue": "CardioVascular and Interventional Radiology"
    },
    {
     "key": "ruggiero2026_evaluation",
     "doi": "10.1016/j.carrev.2025.05.027",
     "url": null,
     "title": "Evaluation of the CorPath-GRX technIQ automated movements during robotic-PCI (NAVIGATE GRX study)",
     "year": 2026,
     "venue": "Cardiovascular Revascularization Medicine"
    },
    {
     "key": "kaneko2026_in",
     "doi": "10.1177/15910199231206315",
     "url": null,
     "title": "In vitro comparison of manual and robotic endovascular thrombectomy for acute ischemic stroke",
     "year": 2023,
     "venue": "Interventional Neuroradiology"
    },
    {
     "key": "tomasello2024_modeling",
     "doi": "10.3174/ajnr.A8205",
     "url": null,
     "title": "Modeling Robotic-Assisted Mechanical Thrombectomy Procedures with the CorPath GRX Robot: The Core-Flow Study",
     "year": 2024,
     "venue": "American Journal of Neuroradiology"
    },
    {
     "key": "williams2025_robotic",
     "doi": "10.5853/jos.2024.05057",
     "url": null,
     "title": "Robotic Stroke Thrombectomy: A Feasibility and Efficacy Study in Flow Models",
     "year": 2025,
     "venue": "Journal of Stroke"
    },
    {
     "key": "alnooryani2018_rotate",
     "doi": "10.1155/2018/6086034",
     "url": null,
     "title": "Rotate-on-Retract Procedural Automation for Robotic-Assisted Percutaneous Coronary Intervention: First Clinical Experience",
     "year": 2018,
     "venue": "Case Reports in Cardiology"
    },
    {
     "key": "winsor2024_performance",
     "doi": "10.1016/j.jscai.2024.102148",
     "url": null,
     "title": "Performance of a Novel Miniaturized Robotic System in Percutaneous Coronary Intervention: A Preclinical Study",
     "year": 2024,
     "venue": "Journal of the Society for Cardiovascular Angiography & Interventions"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (weisz2013_safety, mahmud2016_feasibility: CorPath 200); abstract + web (rest: S8 integration; hamimi2026, tan2026, wagenpfeil2026 abstracts via Europe PMC)",
   "notes": "MARKET EXIT: Siemens Healthineers announced May 2023 it stops selling/developing CorPath for cardiology and peripheral, keeps neurovascular R&D (massdevice/dotmed, via web search summary, not opened). Installed units still reported in 2025-2026 studies. No FDA neuro clearance found; neuro cleared under CE and TGA (mendespereira2020_first). PMDA approval for PCI mid-2018 (mpo-mag 2018-07-19). Siemens+Stryker strategic partnership (2025) for robotic neurovascular system; ARPA-H AIR award up to US$31.1M over 5 y (2026-08-20, Stryker sub-awardee) for autonomous remote thrombectomy; Siemens page: under development, not commercially available. | X2 2026-11-08: PRECISE and RAPID used the CorPath 200, not the GRX (full texts). Gallery adds the GRX control console (media kit) and three paper figures.",
   "maintainers_own": false,
   "found_by": "commercial"
  },
  {
   "schema_version": 1,
   "id": "rone_robocath2019",
   "name": "R-One",
   "full_name": "R-One / R-One+ (next-generation robot)",
   "group": "Robocath (acquired by Stereotaxis, closed 2026-07-07); Cathbot JV with MicroPort MedBot",
   "group_short": "Robocath",
   "family": "commercial",
   "category": "commercial",
   "first_year": 2019,
   "latest_year": 2026,
   "versions": "R-One (CE 2019); R-One+; second-generation robot (up to 5 devices, first-in-human started 2026-01-27, 20 pts planned); R-ONE (NMPA 2023-12-08 via Cathbot JV)",
   "target_anatomy": "coronary (PCI); carotid stenting reported",
   "devices": [
    "guidewire",
    "catheter",
    "therapeutic-device"
   ],
   "devices_driven": "0.014-in guidewire + rapid-exchange balloon/stent catheter; guide catheter manual. Next-gen: up to 5 devices simultaneously (press)",
   "n_dof": 3,
   "n_dof_detail": "3 (gao2026_legobot via S8); 2 in li2024_design (conflict)",
   "translation_mechanism": "other",
   "translation_detail": "other: motorised pads combining translation and rotation",
   "rotation_mechanism": "roller-rolling",
   "rotation_detail": "same pads (coupled with translation)",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "none",
   "haptics_leader": "no",
   "imaging_compat": "standard fluoroscopy; robot placed on table beside patient (official photo)",
   "sterility": "single-use cassette (clear cover visible in company photo)",
   "highest_validation": "human",
   "validation_detail": "R-EVOLUTION 62 pts, 6 sites; registrational trial 145 pts (MicroPort, press); FIH of 2nd-gen 2026 (press)",
   "key_numbers": "R-EVOLUTION: technical success 59/62 (95.2%), clinical success 100%, 3 conversions (1 robot-related); robotic 19.9+-9.6 of 39.9+-14.6 min; operator dose -84.5% under apron (durand2023_evaluation Results, partial). 15 systems installed worldwide (medtechdive, web).",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "A",
    "kind": "product-photo",
    "source": "https://www.robocath.com/wp-content/uploads/2023/04/visuel2.png (listed by robocath.com WordPress media API; page https://www.robocath.com/product/)",
    "source_url": "https://www.robocath.com/wp-content/uploads/2023/04/visuel2.png",
    "licence": "press image (Robocath",
    "credit": "https://www.robocath.com/wp-content/uploads/2023/04/visuel2.png (listed by robocath.com WordPress media API; page https://www.robocath.com/product/). Licence: press image (Robocath.",
    "edits": "cropped (30,30)-(1620,1000) of 1920x1014",
    "file": null
   },
   "pictures": [
    {
     "id": "rone_robocath2019_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Loading a device into the open R-One+ cassette on its arm at the table",
     "source_key": "web:robocath.com",
     "source": "robocath.com, (robocath.com media library)",
     "source_url": "https://www.robocath.com/wp-content/uploads/2024/11/IMG_2880.JPG-1-scaled.jpg",
     "where": "https://www.robocath.com/wp-content/uploads/2024/11/IMG_2880.JPG-1-scaled.jpg (robocath.com media library)",
     "licence": "press image"
    },
    {
     "id": "rone_robocath2019_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Close-up of the R-One bedside unit housing with the Robocath logo",
     "source_key": "web:robocath.com",
     "source": "robocath.com, (robocath.com media library)",
     "source_url": "https://www.robocath.com/wp-content/uploads/2023/04/P1350494-compressed-scaled.jpg",
     "where": "https://www.robocath.com/wp-content/uploads/2023/04/P1350494-compressed-scaled.jpg (robocath.com media library)",
     "licence": "press image"
    },
    {
     "id": "rone_robocath2019_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Physician at the radioprotected control station with joystick and touch screen",
     "source_key": "web:robocath.com",
     "source": "robocath.com, (robocath.com media library)",
     "source_url": "https://www.robocath.com/wp-content/uploads/2024/04/visuel3-scaled-1.jpg",
     "where": "https://www.robocath.com/wp-content/uploads/2024/04/visuel3-scaled-1.jpg (robocath.com media library)",
     "licence": "press image"
    },
    {
     "id": "rone_robocath2019_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Rendering of the control-station joystick panel with catheter and guide keys",
     "source_key": "web:robocath.com",
     "source": "robocath.com, (robocath.com media library)",
     "source_url": "https://www.robocath.com/wp-content/uploads/2023/05/Plan_Joystick_A.jpg",
     "where": "https://www.robocath.com/wp-content/uploads/2023/05/Plan_Joystick_A.jpg (robocath.com media library)",
     "licence": "press image"
    },
    {
     "id": "rone_robocath2019_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Operator seated at the R-One control station during a demonstration",
     "source_key": "web:robocath.com",
     "source": "robocath.com, (robocath.com media library)",
     "source_url": "https://www.robocath.com/wp-content/uploads/2024/11/IMG_2892.JPG-1-scaled.jpg",
     "where": "https://www.robocath.com/wp-content/uploads/2024/11/IMG_2892.JPG-1-scaled.jpg (robocath.com media library)",
     "licence": "press image"
    }
   ],
   "sources": [
    {
     "key": "durand2023_evaluation",
     "doi": "10.4244/eij-d-22-00642",
     "url": null,
     "title": "Evaluation of the R-One robotic system for percutaneous coronary intervention: the R-EVOLUTION study",
     "year": 2023,
     "venue": "EuroIntervention"
    },
    {
     "key": "george2025_robot",
     "doi": "10.1016/j.jscai.2025.102568",
     "url": null,
     "title": "Robot-Assisted Cardiovascular Interventions",
     "year": 2025,
     "venue": "Journal of the Society for Cardiovascular Angiography & Interventions"
    },
    {
     "key": "mandhumula2025_robotic",
     "doi": "10.14797/mdcvj.1652",
     "url": null,
     "title": "Robotic Systems in Cardiovascular Interventions: Evolving Platforms and the Path Forward",
     "year": 2025,
     "venue": "Methodist DeBakey Cardiovascular Journal"
    }
   ],
   "read_level": "partial",
   "read_level_detail": "abstract/partial + web",
   "notes": "Stereotaxis agreed in April 2026 to buy Robocath for up to US$45M (US$20M upfront + US$25M milestones incl. FDA clearance of next-gen system); closing 2026-07-07 (Stereotaxis 10-Q via web summary; medtechdive fetched). No FDA clearance for R-One. NMPA approval for R-ONE 2023-12-08 (MicroPort HKEX filing, via search summary).",
   "maintainers_own": false,
   "found_by": "commercial"
  },
  {
   "schema_version": 1,
   "id": "liberty_microbot2024",
   "name": "LIBERTY",
   "full_name": "LIBERTY Endovascular Robotic System",
   "group": "Microbot Medical",
   "group_short": "Microbot Medical",
   "family": "commercial",
   "category": "commercial",
   "first_year": 2024,
   "latest_year": 2026,
   "versions": "single version; limited market release 2025-2026, full launch from SIR April 2026",
   "target_anatomy": "peripheral arterial/visceral (PAE, UFE, GAE, Y90, peripheral); neurovascular only a stated future target",
   "devices": [
    "guidewire",
    "microcatheter",
    "catheter"
   ],
   "devices_driven": "guide catheter, microcatheter, guidewire (telescopic); standard 0.014-0.018-in guidewires with compatible microcatheters (2-3 F) and guide catheters (4-6 F) (cornelis2026_in p. 3); in the 20-patient study the robot advanced microwire and microcatheter (0.014-0.016-in wires, 2.7 F Progreat or Truselect), guide catheters (typically 5 F) placed by hand (cornelis2026_in p. 3-5, Fig. 2b); tested 0.016-in microwire, 2.4 F microcatheter, 5 F guide (vidal2024_performance)",
   "n_dof": 3,
   "n_dof_detail": "3 (gao2026_legobot via S8); advance, retract, rotate (vidal2024_performance)",
   "translation_mechanism": "friction-roller",
   "translation_detail": "friction-roller (inferred; mechanism not described in vidal2024_performance)",
   "rotation_mechanism": "not-reported",
   "rotation_detail": "N.R.",
   "device_range": "N.R.",
   "footprint_mm": "palm-size drive (vidal2024_performance); 'handheld' system fixed to the angiography table by a mounting arm (cornelis2026_in p. 2-3, Fig. 1b)",
   "mass_kg": "<1 each for drive and wireless hand controller (vidal2024_performance)",
   "force_sensing": "none",
   "haptics_leader": "no: remote controller operable up to 30 ft (9.1 m) away, e.g. from the control room (cornelis2026_in p. 3, Fig. 6b); wireless handheld per vidal2024_performance",
   "imaging_compat": "fluoroscopy with registered DSA overlay (cornelis2026_in Fig. 2a); drive on a mounting arm fixed to the angiography table (Fig. 1b)",
   "sterility": "fully disposable, single-use system: robotic drive, mounting arm and remote controller (cornelis2026_in p. 2, Fig. 1)",
   "highest_validation": "human",
   "validation_detail": "20 pts treated (21 screened), 3 centres (MSKCC, Miami Cardiac & Vascular Institute, Brigham and Women's), 3 interventional radiologists, 3-day follow-up; Y-90 mapping 10, UFE 3, haemangioma 2, TACE 2, sacral, intercostal and pulmonary 1 each; robot removed before embolisation (cornelis2026_in); 2 pigs x 6 operators (vidal2024_performance); simulator benchmark",
   "key_numbers": "navigation to target without conversion 20/20 (95% CI 83.2-100%); robotic navigation 6.3+-7.6 min (median 3, range 1-32) of 120.1+-34.5 min procedure; fluoroscopy median 7.9 min; operator dose median 1.4 uSv (abstract; 1.46 uSv in Table 2) (cornelis2026_in). Wiring on PCI simulator 27.1 s vs manual 36.9 s vs GRX 62.3 s (winsor2024_performance). FDA 510(k) K243789 decided 2025-09-04.",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "A",
    "kind": "product-photo",
    "source": "https://www.microbotmedical.com/wp-content/uploads/2026/04/LIBERTY-Base_image_v2-scaled.webp (RGBA, found via microbotmedical.com WordPress media API; home page https://www.microbotmedical.com/)",
    "source_url": "https://www.microbotmedical.com/wp-content/uploads/2026/04/LIBERTY-Base_image_v2-scaled.webp",
    "licence": "press image (Microbot Medical)",
    "credit": "https://www.microbotmedical.com/wp-content/uploads/2026/04/LIBERTY-Base_image_v2-scaled.webp (RGBA, found via microbotmedical.com WordPress media API; home page https://www.microbotmedical.com/). Licence: press image (Microbot Medical).",
    "edits": "cropped (547,253)-(2095,1499) of 2560x1708, flattened on white; cut = same crop with the publisher alpha (no SAM)",
    "file": null
   },
   "pictures": [
    {
     "id": "liberty_microbot2024_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "LIBERTY drive on its table arm at the patient, operator holding the remote",
     "source_key": "web:microbotmedical.com",
     "source": "microbotmedical.com, (microbotmedical.com home page)",
     "source_url": "https://www.microbotmedical.com/wp-content/uploads/2026/04/Doctor-looking-at-monitor-1240x827.webp",
     "where": "https://www.microbotmedical.com/wp-content/uploads/2026/04/Doctor-looking-at-monitor-1240x827.webp (microbotmedical.com home page)",
     "licence": "press image"
    },
    {
     "id": "liberty_microbot2024_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Wireless hand-held LIBERTY remote controller, product view",
     "source_key": "web:microbotmedical.com",
     "source": "microbotmedical.com, (microbotmedical.com home page)",
     "source_url": "https://www.microbotmedical.com/wp-content/uploads/2026/04/Control_Image-scaled.jpg",
     "where": "https://www.microbotmedical.com/wp-content/uploads/2026/04/Control_Image-scaled.jpg (microbotmedical.com home page)",
     "licence": "press image"
    },
    {
     "id": "liberty_microbot2024_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Articulated mounting arm with clamp that holds the LIBERTY drive",
     "source_key": "web:microbotmedical.com",
     "source": "microbotmedical.com, (microbotmedical.com home page)",
     "source_url": "https://www.microbotmedical.com/wp-content/uploads/2026/04/LIBERTY-arm_image-scaled.jpg",
     "where": "https://www.microbotmedical.com/wp-content/uploads/2026/04/LIBERTY-arm_image-scaled.jpg (microbotmedical.com home page)",
     "licence": "press image"
    },
    {
     "id": "liberty_microbot2024_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Drive, mounting arm, hand-held remote and clinical set-up drawing",
     "source_key": "vidal2024_performance",
     "source": "Vidal et al., CardioVascular and Interventional Radiology (2024), Fig. 1, p. 3",
     "source_url": "https://doi.org/10.1007/s00270-024-03686-0",
     "where": "Fig. 1, p. 3",
     "licence": "publisher copyright"
    },
    {
     "id": "liberty_microbot2024_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "Disposable robotic drive and wireless remote controller, product view",
     "source_key": "cornelis2026_in",
     "source": "Cornelis et al., Journal of Vascular and Interventional Radiology (2026), Fig. 1(a), p. 3",
     "source_url": "https://doi.org/10.1016/j.jvir.2026.108591",
     "where": "Fig. 1(a), p. 3",
     "licence": "publisher copyright"
    },
    {
     "id": "liberty_microbot2024_06",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Drive on its mounting arm fixed to the angiography table (arrow)",
     "source_key": "cornelis2026_in",
     "source": "Cornelis et al., Journal of Vascular and Interventional Radiology (2026), Fig. 1(b), p. 3",
     "source_url": "https://doi.org/10.1016/j.jvir.2026.108591",
     "where": "Fig. 1(b), p. 3",
     "licence": "publisher copyright"
    },
    {
     "id": "liberty_microbot2024_07",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Operator steering with the hand-held remote from the control room",
     "source_key": "cornelis2026_in",
     "source": "Cornelis et al., Journal of Vascular and Interventional Radiology (2026), Fig. 6(b), p. 6",
     "source_url": "https://doi.org/10.1016/j.jvir.2026.108591",
     "where": "Fig. 6(b), p. 6",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "fda2025_k243789",
     "doi": null,
     "url": "https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfPMN/pmn.cfm?ID=K243789",
     "title": "510(k) Premarket Notification K243789: LIBERTY Endovascular Robotic System (Microbot Medical, Ltd.)",
     "year": 2025,
     "venue": null
    },
    {
     "key": "cornelis2026_in",
     "doi": "10.1016/j.jvir.2026.108591",
     "url": null,
     "title": "In Vivo Evaluation of a Disposable Endovascular Robotic System for Arterial Peripheral Vascular Interventions: A Multicenter Feasibility Study",
     "year": 2026,
     "venue": "Journal of Vascular and Interventional Radiology"
    },
    {
     "key": "vidal2024_performance",
     "doi": "10.1007/s00270-024-03686-0",
     "url": null,
     "title": "Performance Evaluation of a Miniature and Disposable Endovascular Robotic Device",
     "year": 2024,
     "venue": "CardioVascular and Interventional Radiology"
    },
    {
     "key": "moschovakizeiger2024_safety",
     "doi": "10.1186/s42155-024-00425-x",
     "url": null,
     "title": "Safety and feasibility study of a novel robotic system in an in vivo porcine vascular model",
     "year": 2024,
     "venue": "CVIR Endovascular"
    },
    {
     "key": "winsor2024_performance",
     "doi": "10.1016/j.jscai.2024.102148",
     "url": null,
     "title": "Performance of a Novel Miniaturized Robotic System in Percutaneous Coronary Intervention: A Preclinical Study",
     "year": 2024,
     "venue": "Journal of the Society for Cardiovascular Angiography & Interventions"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (cornelis2026_in); abstract + web (rest)",
   "notes": "Remote ability: Corewell Health teleintervention collaboration did simulated navigation between two sites 5 miles apart (web summary, simulation only). Neuro not yet. Nasdaq/PR: full launch April 2026, territories 4 to 8, goal 12 by end 2026. | X2 2026-11-08: cornelis2026_in read in full; mechanism and DOF count not described there.",
   "maintainers_own": false,
   "found_by": "commercial"
  },
  {
   "schema_version": 1,
   "id": "sentante_sentante2022",
   "name": "SENTANTE",
   "full_name": "SENTANTE Endovascular Robotic System",
   "group": "UAB Inovatyvi Medicina (Sentante)",
   "group_short": "Sentante",
   "family": "commercial",
   "category": "commercial",
   "first_year": 2022,
   "latest_year": 2026,
   "versions": "single platform; CE mark reported 2026-05-22; commercial rollout announced 2026-08-20 (unite.ai only, lower certainty)",
   "target_anatomy": "peripheral, visceral; vertebral stenting in pigs; stroke thrombectomy shown on cadaver models (press)",
   "devices": [
    "guidewire",
    "catheter"
   ],
   "devices_driven": "3 coaxial: one guidewire 0.014-0.035 in + two over-the-wire catheters 2-8 Fr; standard off-the-shelf devices",
   "n_dof": 2,
   "n_dof_detail": "2 per device (advance, rotate), 3 devices",
   "translation_mechanism": "other",
   "translation_detail": "other: paired sterile cassettes grip device and travel on rails",
   "rotation_mechanism": "rotating-drive-unit",
   "rotation_detail": "cassette rotation",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "yes: bedside unit measures manipulation force",
   "haptics_leader": "yes: leader uses real catheter/guidewire at workstation, reflects measured force",
   "imaging_compat": "remote workstation outside X-ray field",
   "sterility": "3 pairs of sterile single-use cassettes",
   "highest_validation": "human",
   "validation_detail": "ESSENTIAL first-in-human started July 2024, Paula Stradins hospital Riga (press; NCT06537947); 6 pigs; 24 GLP remote animal procedures and transatlantic cadaver thrombectomy (press)",
   "key_numbers": "pig study: no angiographic vessel injury; minimal trauma 3/16 vessels at necropsy (huistra2026_evaluation abstract). ESSENTIAL: 100% technical success, 0 device complications (unite.ai, unverified press).",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "render",
    "source": "https://sentante.com/wp-content/uploads/2025/12/Frame-2087328849-min.jpg (home page https://sentante.com/)",
    "source_url": "https://sentante.com/wp-content/uploads/2025/12/Frame-2087328849-min.jpg",
    "licence": "press image (Sentante)",
    "credit": "https://sentante.com/wp-content/uploads/2025/12/Frame-2087328849-min.jpg (home page https://sentante.com/). Licence: press image (Sentante).",
    "edits": "cropped (930,455)-(2350,1405) of 2800x1680 (bedside rail unit + mast + monitor, C-arm cut away)",
    "file": null
   },
   "pictures": [
    {
     "id": "sentante_sentante2022_01",
     "status": "cleared",
     "file": "pictures/extra/sentante_sentante2022_01.jpg",
     "thumb": "pictures/thumbs/sentante_sentante2022_01.jpg",
     "kind": "close-up",
     "caption": "Bedside unit cassettes holding three endovascular devices, close view",
     "source_key": "huistra2026_evaluation",
     "source": "Huistra et al., CardioVascular and Interventional Radiology (2026), Fig. 1(B), p. 3",
     "source_url": "https://doi.org/10.1007/s00270-026-04375-w",
     "where": "Fig. 1(B), p. 3",
     "licence": "CC BY 4.0"
    },
    {
     "id": "sentante_sentante2022_02",
     "status": "cleared",
     "file": "pictures/extra/sentante_sentante2022_02.jpg",
     "thumb": "pictures/thumbs/sentante_sentante2022_02.jpg",
     "kind": "leader",
     "caption": "Remote workstation and the operator moving the input device by hand",
     "source_key": "huistra2026_evaluation",
     "source": "Huistra et al., CardioVascular and Interventional Radiology (2026), Fig. 2, p. 4",
     "source_url": "https://doi.org/10.1007/s00270-026-04375-w",
     "where": "Fig. 2, p. 4",
     "licence": "CC BY 4.0"
    },
    {
     "id": "sentante_sentante2022_03",
     "status": "cleared",
     "file": "pictures/extra/sentante_sentante2022_03.jpg",
     "thumb": "pictures/thumbs/sentante_sentante2022_03.jpg",
     "kind": "leader",
     "caption": "Workstation INFLATE unit for remote balloon inflation and contrast injection",
     "source_key": "huistra2026_evaluation",
     "source": "Huistra et al., CardioVascular and Interventional Radiology (2026), Fig. 3, p. 4",
     "source_url": "https://doi.org/10.1007/s00270-026-04375-w",
     "where": "Fig. 3, p. 4",
     "licence": "CC BY 4.0"
    },
    {
     "id": "sentante_sentante2022_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Rendering of the rail-mounted bedside unit on the table under the C-arm",
     "source_key": "web:sentante.com",
     "source": "sentante.com, (sentante.com media library)",
     "source_url": "https://sentante.com/wp-content/uploads/2025/12/Frame-2087328848-min.jpg",
     "where": "https://sentante.com/wp-content/uploads/2025/12/Frame-2087328848-min.jpg (sentante.com media library)",
     "licence": "press image"
    },
    {
     "id": "sentante_sentante2022_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Rendering of a hybrid room with bedside unit and separate workstation room",
     "source_key": "web:sentante.com",
     "source": "sentante.com, (sentante.com media library)",
     "source_url": "https://sentante.com/wp-content/uploads/2026/06/room_desktop.png",
     "where": "https://sentante.com/wp-content/uploads/2026/06/room_desktop.png (sentante.com media library)",
     "licence": "press image"
    }
   ],
   "sources": [
    {
     "key": "huistra2026_evaluation",
     "doi": "10.1007/s00270-026-04375-w",
     "url": null,
     "title": "Evaluation of Fully Teleoperated Robotic Endovascular Interventions with Haptic Feedback: The SENTANTE Endovascular Robotic System",
     "year": 2026,
     "venue": "CardioVascular and Interventional Radiology"
    },
    {
     "key": "mandhumula2025_robotic",
     "doi": "10.14797/mdcvj.1652",
     "url": null,
     "title": "Robotic Systems in Cardiovascular Interventions: Evolving Platforms and the Path Forward",
     "year": 2025,
     "venue": "Methodist DeBakey Cardiovascular Journal"
    },
    {
     "key": "george2025_robot",
     "doi": "10.1016/j.jscai.2025.102568",
     "url": null,
     "title": "Robot-Assisted Cardiovascular Interventions",
     "year": 2025,
     "venue": "Journal of the Society for Cardiovascular Angiography & Interventions"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full text on disk (survey txt) for huistra; web for CE",
   "notes": "Only teleoperated system with true device-handle haptics among commercial systems found.",
   "maintainers_own": false,
   "found_by": "commercial"
  },
  {
   "schema_version": 1,
   "id": "iris_xcath2025",
   "name": "Iris",
   "full_name": "Iris Surgical Robotic System (XCath EVR)",
   "group": "XCath",
   "group_short": "XCath",
   "family": "commercial",
   "category": "clinical-stage",
   "first_year": 2025,
   "latest_year": 2026,
   "versions": "EVR (earlier name); Iris",
   "target_anatomy": "neurovascular (intracranial): aneurysm treatment, thrombectomy",
   "devices": [
    "guidewire",
    "microcatheter",
    "catheter",
    "sheath"
   ],
   "devices_driven": "steerable guidewire with electroactive-polymer tip; catheters/sheath; microcatheters (per press)",
   "n_dof": null,
   "n_dof_detail": "N.R.",
   "translation_mechanism": "other",
   "translation_detail": "other: pinch rollers for catheter (mandhumula2025_robotic via S8)",
   "rotation_mechanism": "not-reported",
   "rotation_detail": "N.R.",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "none reported",
   "haptics_leader": "no (joystick console visible in photo)",
   "imaging_compat": "works on monoplane angiography (company claim)",
   "sterility": "N.R.",
   "highest_validation": "human",
   "validation_detail": "3 aneurysm pts, Panama Clinic, Nov 2025 (press); 1 telerobotic thrombectomy, Panama, ~200 km, March 2026 (press); both company-reported",
   "key_numbers": "telerobotic thrombectomy: NIHSS 21 LVO, mTICI 3, first pass (hitconsultant 2026-03-20). Series C US$30M March 2026, total US$92M (pulse2/massdevice).",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "render",
    "source": "https://xcath.com/images/iris.png (home page https://xcath.com/)",
    "source_url": "https://xcath.com/images/iris.png",
    "licence": "press image (XCath)",
    "credit": "https://xcath.com/images/iris.png (home page https://xcath.com/). Licence: press image (XCath).",
    "edits": "cropped (222,123)-(1672,1006) of 1920x1080 RGBA, flattened on white; cut = same crop with the publisher alpha; not upscaled; no tone change; no erasing",
    "file": null
   },
   "pictures": [
    {
     "id": "iris_xcath2025_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "XCath console with two joysticks and touch screen in the Santiago control room",
     "source_key": "web:hitconsultant.net",
     "source": "hitconsultant.net, (HIT Consultant, 2026-03)",
     "source_url": "https://hitconsultant.net/wp-content/uploads/2026/03/XCath_Team_Santiago_Control_Room_DrPereira_Dr_Moll_for_wire-1500x841.jpg",
     "where": "https://hitconsultant.net/wp-content/uploads/2026/03/XCath_Team_Santiago_Control_Room_DrPereira_Dr_Moll_for_wire-1500x841.jpg (HIT Consultant, 2026-03)",
     "licence": "press image"
    }
   ],
   "sources": [
    {
     "key": "mandhumula2025_robotic",
     "doi": "10.14797/mdcvj.1652",
     "url": null,
     "title": "Robotic Systems in Cardiovascular Interventions: Evolving Platforms and the Path Forward",
     "year": 2025,
     "venue": "Methodist DeBakey Cardiovascular Journal"
    },
    {
     "key": "chen2026_teleoperation",
     "doi": "10.1109/TMRB.2026.3681030",
     "url": null,
     "title": "Remote Teleoperation of Endovascular Intervention Robots: A Systematic Review",
     "year": 2026,
     "venue": "IEEE Transactions on Medical Robotics and Bionics"
    }
   ],
   "read_level": "web",
   "read_level_detail": "web",
   "notes": "Not cleared by any regulator (Endovascular Today 2026-03-25 per S8). Operator Vitor Mendes Pereira, also lead of GRX neuro series. No peer-reviewed paper found.",
   "maintainers_own": false,
   "found_by": "commercial"
  },
  {
   "schema_version": 1,
   "id": "n1_remedy2025",
   "name": "N1",
   "full_name": "N1 System",
   "group": "Remedy Robotics",
   "group_short": "Remedy Robotics",
   "family": "commercial",
   "category": "clinical-stage",
   "first_year": 2025,
   "latest_year": 2026,
   "versions": "N1",
   "target_anatomy": "neurovascular / general (stroke, MI, trauma per company)",
   "devices": [
    "other"
   ],
   "devices_driven": "up to 4 passive instruments (chen2026_teleoperation via S8)",
   "n_dof": null,
   "n_dof_detail": "N.R.",
   "translation_mechanism": "not-reported",
   "translation_detail": "N.R.",
   "rotation_mechanism": "not-reported",
   "rotation_detail": "N.R.",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "none reported",
   "haptics_leader": "N.R.",
   "imaging_compat": "remote operation across hospitals",
   "sterility": "N.R.",
   "highest_validation": "human",
   "validation_detail": "fully remote brain angiogram between two Toronto hospitals, Oct 2025, operator V. Mendes Pereira (therobotreport, ieee spectrum via search; case count N.R.); remote silicone-model navigation over 12,800 km (chen2026_teleoperation)",
   "key_numbers": "US$35M raised (Axios Oct 2025 via therobotreport); 45 patents (search summary)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "clinical-photo",
    "source": "https://unityhealth.to/wp-content/uploads/2025/09/2509-cut-the-cord-1500-1000c.jpg (Unity Health Toronto story https://unityhealth.to/2025/11/first-robotic-assisted-neurovascular-procedure/)",
    "source_url": "https://unityhealth.to/wp-content/uploads/2025/09/2509-cut-the-cord-1500-1000c.jpg",
    "licence": "press image (Unity Health Toronto; photographer credit on the page)",
    "credit": "https://unityhealth.to/wp-content/uploads/2025/09/2509-cut-the-cord-1500-1000c.jpg (Unity Health Toronto story https://unityhealth.to/2025/11/first-robotic-assisted-neurovascular-procedure/). Licence: press image (Unity Health Toronto; photographer credit on the page).",
    "edits": "cropped (380,250)-(1280,880) of 1500x1000; not upscaled; no tone change; no erasing",
    "file": null
   },
   "pictures": [
    {
     "id": "n1_remedy2025_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Draped N1 bedside unit at the angiography table with the treating team",
     "source_key": "web:unityhealth.to",
     "source": "unityhealth.to, (Unity Health Toronto story, 2025-11)",
     "source_url": "https://unityhealth.to/wp-content/uploads/2025/09/2509-cut-the-cord-1500-1000d.jpg",
     "where": "https://unityhealth.to/wp-content/uploads/2025/09/2509-cut-the-cord-1500-1000d.jpg (Unity Health Toronto story, 2025-11)",
     "licence": "press image"
    },
    {
     "id": "n1_remedy2025_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Neurointerventionalist at the remote N1 workstation outside the procedure room",
     "source_key": "web:unityhealth.to",
     "source": "unityhealth.to, (Unity Health Toronto story, 2025-11)",
     "source_url": "https://unityhealth.to/wp-content/uploads/2025/09/2509-cut-the-cord-1500-1000a.jpg",
     "where": "https://unityhealth.to/wp-content/uploads/2025/09/2509-cut-the-cord-1500-1000a.jpg (Unity Health Toronto story, 2025-11)",
     "licence": "press image"
    }
   ],
   "sources": [
    {
     "key": "chen2026_teleoperation",
     "doi": "10.1109/TMRB.2026.3681030",
     "url": null,
     "title": "Remote Teleoperation of Endovascular Intervention Robots: A Systematic Review",
     "year": 2026,
     "venue": "IEEE Transactions on Medical Robotics and Bionics"
    }
   ],
   "read_level": "web",
   "read_level_detail": "web",
   "notes": "No clearance found (June 2026 summaries say N1 not yet for sale). Mission Thrombectomy exclusive robotics partner (Oct 2025); Australian Stroke Alliance partnership. Head of Regulatory Affairs job posting seen.",
   "maintainers_own": false,
   "found_by": "commercial"
  },
  {
   "schema_version": 1,
   "id": "niobe_stereotaxis2003",
   "name": "Niobe / Genesis",
   "full_name": "Niobe / Genesis / GenesisX Robotic Magnetic Navigation",
   "group": "Stereotaxis",
   "group_short": "Stereotaxis",
   "family": "commercial",
   "category": "magnetic-navigation",
   "first_year": 2003,
   "latest_year": 2026,
   "versions": "Niobe ES (2003-); Genesis (FDA 2020 per ren2023_critical); GenesisX (FDA 510(k) 2025-11-10, limited launch)",
   "target_anatomy": "cardiac electrophysiology (ablation, AF); coronary/peripheral use reported historically",
   "devices": [
    "guidewire",
    "catheter"
   ],
   "devices_driven": "magnetic-tip catheters and guidewires; Vdrive advancer",
   "n_dof": 3,
   "n_dof_detail": "3 (li2024_design Table I)",
   "translation_mechanism": "magnetic",
   "translation_detail": "magnetic",
   "rotation_mechanism": "magnetic-field",
   "rotation_detail": "tip direction by external field (two permanent magnets, 0.08-0.12 T, mandhumula2025_robotic)",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "none in robot; contact-force catheters integrated",
   "haptics_leader": "no",
   "imaging_compat": "fluoroscopy/mapping integrated (EP lab)",
   "sterility": "disposable advancer parts (N.R. detail)",
   "highest_validation": "human",
   "validation_detail": "thousands of EP cases historically (N.R. exact in sources opened)",
   "key_numbers": "GenesisX 510(k) Nov 2025 (medtechdive/dicardiology via search, not opened)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "render",
    "source": "https://www.stereotaxis.com/wp-content/uploads/2024/09/Genesis-Product-Image-scaled.webp (page https://www.stereotaxis.com/products/)",
    "source_url": "https://www.stereotaxis.com/wp-content/uploads/2024/09/Genesis-Product-Image-scaled.webp",
    "licence": "press image (Stereotaxis)",
    "credit": "https://www.stereotaxis.com/wp-content/uploads/2024/09/Genesis-Product-Image-scaled.webp (page https://www.stereotaxis.com/products/). Licence: press image (Stereotaxis).",
    "edits": "cropped (1,42)-(2559,1239) of 2560x1280 RGBA, flattened on white; cut = publisher alpha",
    "file": null
   },
   "pictures": [
    {
     "id": "niobe_stereotaxis2003_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Genesis RMN magnet arms around the table in the Warsaw electrophysiology lab",
     "source_key": "web:stereotaxis.com",
     "source": "stereotaxis.com",
     "source_url": "https://www.stereotaxis.com/wp-content/uploads/2024/08/1.-Stereotaxis-Genesis-RMN-system-in-the-robotic-electrophysiology-lab-at-the-National-Institute-of-Cardiology-in-Warsaw-Poland-2-scaled.jpg",
     "where": "https://www.stereotaxis.com/wp-content/uploads/2024/08/1.-Stereotaxis-Genesis-RMN-system-in-the-robotic-electrophysiology-lab-at-the-National-Institute-of-Cardiology-in-Warsaw-Poland-2-scaled.jpg",
     "licence": "press image"
    },
    {
     "id": "niobe_stereotaxis2003_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "GenesisX magnet pods and patient table, front product view",
     "source_key": "web:stereotaxis.com",
     "source": "stereotaxis.com",
     "source_url": "https://www.stereotaxis.com/wp-content/uploads/2024/09/GenesisX-Product-Image-1-scaled.webp",
     "where": "https://www.stereotaxis.com/wp-content/uploads/2024/09/GenesisX-Product-Image-1-scaled.webp",
     "licence": "press image"
    },
    {
     "id": "niobe_stereotaxis2003_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "GenesisX system, quarter-angle product view with table and C-arm",
     "source_key": "web:stereotaxis.com",
     "source": "stereotaxis.com",
     "source_url": "https://www.stereotaxis.com/wp-content/uploads/2024/10/GenesisX-qtr-angle@3x-2.png",
     "where": "https://www.stereotaxis.com/wp-content/uploads/2024/10/GenesisX-qtr-angle@3x-2.png",
     "licence": "press image"
    },
    {
     "id": "niobe_stereotaxis2003_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Genesis lab viewed from the control room with navigation workstation",
     "source_key": "web:stereotaxis.com",
     "source": "stereotaxis.com",
     "source_url": "https://www.stereotaxis.com/wp-content/uploads/2021/11/Genesis-Clinical-Lab.jpg",
     "where": "https://www.stereotaxis.com/wp-content/uploads/2021/11/Genesis-Clinical-Lab.jpg",
     "licence": "press image"
    }
   ],
   "sources": [
    {
     "key": "ren2023_critical",
     "doi": "10.1109/jsen.2023.3320356",
     "url": null,
     "title": "The Critical Technologies of Vascular Interventional Robotic Catheterization: A Review",
     "year": 2023,
     "venue": "IEEE Sensors Journal"
    },
    {
     "key": "li2024_design",
     "doi": "10.1109/tmrb.2024.3377374",
     "url": null,
     "title": "Robotic Systems Design in Endovascular Treatment",
     "year": 2024,
     "venue": "IEEE Transactions on Medical Robotics and Bionics"
    },
    {
     "key": "mandhumula2025_robotic",
     "doi": "10.14797/mdcvj.1652",
     "url": null,
     "title": "Robotic Systems in Cardiovascular Interventions: Evolving Platforms and the Path Forward",
     "year": 2025,
     "venue": "Methodist DeBakey Cardiovascular Journal"
    },
    {
     "key": "crinnion2022_robotics",
     "doi": "10.1136/neurintsurg-2021-018096",
     "url": null,
     "title": "Robotics in neurointerventional surgery: a systematic review of the literature",
     "year": 2021,
     "venue": "Journal of NeuroInterventional Surgery"
    }
   ],
   "read_level": "web",
   "read_level_detail": "web",
   "notes": "Stereotaxis bought Robocath 2026 (see rone row): now owns a mechanical-drive PCI robot plus magnetic EP robot.",
   "maintainers_own": false,
   "found_by": "commercial"
  },
  {
   "schema_version": 1,
   "id": "sensei_hansen2007",
   "name": "Sensei X",
   "full_name": "Sensei / Sensei X",
   "group": "Hansen Medical (Auris 2016; J&J 2019)",
   "group_short": "Hansen Medical",
   "family": "commercial",
   "category": "commercial",
   "first_year": 2007,
   "latest_year": 2019,
   "versions": "Sensei, Sensei X, Sensei X2 (catalogue no. SRS200; brochure LT0200 Rev. B, (c) 2014) (discontinued)",
   "target_anatomy": "cardiac EP",
   "devices": [
    "catheter",
    "sheath"
   ],
   "devices_driven": "proprietary robotically steerable sheath (Artisan / Artisan Extend control catheter, inner and outer guide) carrying a mapping catheter (Boston Scientific Polaris-Dx or St. Jude Livewire per the indications) (hansen2016_sensei-x2_BROCHURE pp. 3, 6); outer 14 F per ren2023_critical; 14/10.5 F per mandhumula2025_robotic",
   "n_dof": 6,
   "n_dof_detail": "6 (li2024_design Table I)",
   "translation_mechanism": "tendon/tip-actuation",
   "translation_detail": "tendon/tip-actuation",
   "rotation_mechanism": "tendon-bending",
   "rotation_detail": "tendon-driven bending",
   "device_range": "inner guide bends up to 275 degrees, outer guide 90 degrees articulation (brochure p. 3); auto-retract from 1 mm per half second to 10 mm/s with 1 mm precision; motion scaling 4:1, 3:1 or 2:1 (brochure p. 4)",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "IntelliSense distal contact force estimate with visual/vibration cue; 'Intellisense Fine Force Technology' shown in visual and tactile formats (brochure p. 4)",
   "haptics_leader": "remote physician workstation with monitors and a motion controller (brochure p. 2 photo); IntelliSense vibration cue only",
   "imaging_compat": "integrates 3D mapping (CARTO, EnSite Velocity), ICE, fluoroscopy and EKG recording (brochure pp. 2-3)",
   "sterility": "Sensei System Artisan Drape (8 pack, cat. no. 06196) (brochure p. 6)",
   "highest_validation": "human",
   "validation_detail": "EP clinical use: over 14,000 procedures, 26 studies, over 2,700 patients studied (brochure p. 5, company figures)",
   "key_numbers": "radiation time 17.0 -> 11.0 (35% reduction; axis unit printed 'mm') at one hospital after starting a Sensei programme (brochure p. 5, citing Kaplan 2013); 2x tip stability vs a manual catheter (company bench data, brochure p. 4)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "A",
    "kind": "product-photo",
    "source": "Hansen Medical \"Sensei X2 Brochure_US LT0200 Rev. B\" p2 embedded image xref 10 with its soft mask, from https://web.archive.org/web/2016id_/http://www.hansenmedical.com:80/sites/default/files/blob-file/Sensei%20X2%20Brochure_US%20LT0200%20Rev.%20B_2.pdf",
    "source_url": "https://web.archive.org/web/2016id_/http://www.hansenmedical.com:80/sites/default/files/blob-file/Sensei%20X2%20Brochure_US%20LT0200%20Rev.%20B_2.pdf",
    "licence": "press image (Hansen Medical marketing brochure, archived; company defunct, assets now J&J/Auris)",
    "credit": "Hansen Medical \"Sensei X2 Brochure_US LT0200 Rev. B\" p2 embedded image xref 10 with its soft mask, from https://web.archive.org/web/2016id_/http://www.hansenmedical.com:80/sites/default/files/blob-file/Sensei%20X2%20Brochure_US%20LT0200%20Rev.%20B_2.pdf. Licence: press image (Hansen Medical marketing brochure, archived; company defunct, assets now J&J/Auris).",
    "edits": "image + soft mask, cropped to (0,0)-(2592,1140), flattened on white; cut = brochure soft mask (no SAM)",
    "file": null
   },
   "pictures": [
    {
     "id": "sensei_hansen2007_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Sensei X2 remote catheter manipulator with two Artisan splayers on its setup arm",
     "source_key": "hansen2016_sensei-x2_BROCHURE",
     "source": "Medical (2014), brochure LT0200 Rev. B, p. 1 (cover photo, embedded image)",
     "source_url": null,
     "where": "brochure LT0200 Rev. B, p. 1 (cover photo, embedded image)",
     "licence": "press image"
    },
    {
     "id": "sensei_hansen2007_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Remote physician workstation with three monitors and the instinctive motion controller",
     "source_key": "hansen2016_sensei-x2_BROCHURE",
     "source": "Medical (2014), brochure LT0200 Rev. B, p. 2 (embedded image)",
     "source_url": null,
     "where": "brochure LT0200 Rev. B, p. 2 (embedded image)",
     "licence": "press image"
    }
   ],
   "sources": [
    {
     "key": "li2024_design",
     "doi": "10.1109/tmrb.2024.3377374",
     "url": null,
     "title": "Robotic Systems Design in Endovascular Treatment",
     "year": 2024,
     "venue": "IEEE Transactions on Medical Robotics and Bionics"
    },
    {
     "key": "ren2023_critical",
     "doi": "10.1109/jsen.2023.3320356",
     "url": null,
     "title": "The Critical Technologies of Vascular Interventional Robotic Catheterization: A Review",
     "year": 2023,
     "venue": "IEEE Sensors Journal"
    },
    {
     "key": "mandhumula2025_robotic",
     "doi": "10.14797/mdcvj.1652",
     "url": null,
     "title": "Robotic Systems in Cardiovascular Interventions: Evolving Platforms and the Path Forward",
     "year": 2025,
     "venue": "Methodist DeBakey Cardiovascular Journal"
    },
    {
     "key": "crinnion2022_robotics",
     "doi": "10.1136/neurintsurg-2021-018096",
     "url": null,
     "title": "Robotics in neurointerventional surgery: a systematic review of the literature",
     "year": 2021,
     "venue": "Journal of NeuroInterventional Surgery"
    },
    {
     "key": "chen2023_operating",
     "doi": "10.1109/tmrb.2023.3272049",
     "url": null,
     "title": "The Catheter and Guidewire Operating Systems of Vascular Interventional Surgical Robots: A Systematic Review",
     "year": 2023,
     "venue": "IEEE Transactions on Medical Robotics and Bionics"
    },
    {
     "key": "hansen2016_sensei-x2_BROCHURE",
     "doi": null,
     "url": null,
     "title": "Sensei X2 Robotic Catheter System brochure (LT0200 Rev. B)",
     "year": 2014,
     "venue": null
    }
   ],
   "read_level": "abstract",
   "read_level_detail": "brochure (full, hansen2016_sensei-x2_BROCHURE); abstract (S8)",
   "notes": "Commercially discontinued; Hansen bought by Auris 2016 (US$80M), Auris by J&J 2019 (US$3.4B) (S8 via chen2023_operating). FDA record not opened. | X2 2026-11-08: Sensei X2 brochure read in full (press material, internal use).",
   "maintainers_own": false,
   "found_by": "commercial"
  },
  {
   "schema_version": 1,
   "id": "magellan_hansen2012",
   "name": "Magellan",
   "full_name": "Magellan Robotic System",
   "group": "Hansen Medical (Auris)",
   "group_short": "Hansen Medical",
   "family": "commercial",
   "category": "commercial",
   "first_year": 2012,
   "latest_year": 2019,
   "versions": "Magellan Robotic System with the Magellan robotic catheter, formerly Northstar robotic catheter (brochure LT0040 Rev C, (c) 2012); 9 F sheath / 6 F leader",
   "target_anatomy": "multi-specialty peripheral vascular (indication: navigation to anatomical targets in the peripheral vasculature, then a conduit for manual placement of therapeutic devices, hansen2016_magellan_BROCHURE p. 2); aortic; neurovascular case series (23 pts per chen2023_operating; 9 angiograms + 18 interventions per miyachi2025_robotics - conflict)",
   "devices": [
    "guidewire",
    "catheter",
    "sheath"
   ],
   "devices_driven": "proprietary Magellan robotic catheter giving distal tip control of guidewires, catheters and guide (brochure p. 1); steerable sheath 9 F and leader 6 F; guidewire 0.014-0.035 in",
   "n_dof": 6,
   "n_dof_detail": "6 (li2024_design Table I)",
   "translation_mechanism": "tendon/tip-actuation",
   "translation_detail": "tendon/tip-actuation",
   "rotation_mechanism": "tendon-bending",
   "rotation_detail": "belt friction drive for guidewire; tendon-driven catheters",
   "device_range": "N.R.",
   "footprint_mm": "N.R. (robotic arm at the patient table + remote physician workstation; 'no specialized construction necessary', brochure p. 1)",
   "mass_kg": "N.R.",
   "force_sensing": "none",
   "haptics_leader": "no: remote physician workstation away from the radiation source (brochure p. 1)",
   "imaging_compat": "N.R.",
   "sterility": "N.R.",
   "highest_validation": "human",
   "validation_detail": ">1000 cases clinically (huistra2026_evaluation intro)",
   "key_numbers": "FDA approval 2012 for PVI as written by crinnion2022_robotics (a 510(k) clearance is likely; record not opened)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "A",
    "kind": "product-photo",
    "source": "Hansen Medical \"Magellan Robotic System Brochure\" p2 embedded image xref 23 with its soft mask, from https://web.archive.org/web/2016id_/http://www.hansenmedical.com:80/sites/default/files/blob-file/Hansen-Medical-Magellan-Robotic-System-Brochure.pdf",
    "source_url": "https://web.archive.org/web/2016id_/http://www.hansenmedical.com:80/sites/default/files/blob-file/Hansen-Medical-Magellan-Robotic-System-Brochure.pdf",
    "licence": "press image (Hansen Medical marketing brochure, archived)",
    "credit": "Hansen Medical \"Magellan Robotic System Brochure\" p2 embedded image xref 23 with its soft mask, from https://web.archive.org/web/2016id_/http://www.hansenmedical.com:80/sites/default/files/blob-file/Hansen-Medical-Magellan-Robotic-System-Brochure.pdf. Licence: press image (Hansen Medical marketing brochure, archived).",
    "edits": "image + soft mask, cropped (20,90)-(2172,1120), flattened on white; cut = brochure soft mask",
    "file": null
   },
   "pictures": [
    {
     "id": "magellan_hansen2012_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Remote catheter manipulator rail with sheath and leader splayers loaded",
     "source_key": "hansen2016_magellan_BROCHURE",
     "source": "Medical (2012), brochure LT0040 Rev C, p. 1 (embedded image)",
     "source_url": null,
     "where": "brochure LT0040 Rev C, p. 1 (embedded image)",
     "licence": "press image"
    },
    {
     "id": "magellan_hansen2012_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Physician at the remote workstation, bedside arm on the table behind",
     "source_key": "hansen2016_magellan_BROCHURE",
     "source": "Medical (2012), brochure LT0040 Rev C, p. 3 (embedded image)",
     "source_url": null,
     "where": "brochure LT0040 Rev C, p. 3 (embedded image)",
     "licence": "press image"
    },
    {
     "id": "magellan_hansen2012_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Remote physician workstation with monitor, touchscreen and motion controller",
     "source_key": "hansen2016_magellan_BROCHURE",
     "source": "Medical (2012), brochure LT0040 Rev C, p. 2 (embedded image)",
     "source_url": null,
     "where": "brochure LT0040 Rev C, p. 2 (embedded image)",
     "licence": "press image"
    },
    {
     "id": "magellan_hansen2012_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Magellan robotic catheter (formerly Northstar) with its articulating tip",
     "source_key": "hansen2016_magellan_BROCHURE",
     "source": "Medical (2012), brochure LT0040 Rev C, p. 2 (embedded image)",
     "source_url": null,
     "where": "brochure LT0040 Rev C, p. 2 (embedded image)",
     "licence": "press image"
    }
   ],
   "sources": [
    {
     "key": "li2024_design",
     "doi": "10.1109/tmrb.2024.3377374",
     "url": null,
     "title": "Robotic Systems Design in Endovascular Treatment",
     "year": 2024,
     "venue": "IEEE Transactions on Medical Robotics and Bionics"
    },
    {
     "key": "ren2023_critical",
     "doi": "10.1109/jsen.2023.3320356",
     "url": null,
     "title": "The Critical Technologies of Vascular Interventional Robotic Catheterization: A Review",
     "year": 2023,
     "venue": "IEEE Sensors Journal"
    },
    {
     "key": "crinnion2022_robotics",
     "doi": "10.1136/neurintsurg-2021-018096",
     "url": null,
     "title": "Robotics in neurointerventional surgery: a systematic review of the literature",
     "year": 2021,
     "venue": "Journal of NeuroInterventional Surgery"
    },
    {
     "key": "mandhumula2025_robotic",
     "doi": "10.14797/mdcvj.1652",
     "url": null,
     "title": "Robotic Systems in Cardiovascular Interventions: Evolving Platforms and the Path Forward",
     "year": 2025,
     "venue": "Methodist DeBakey Cardiovascular Journal"
    },
    {
     "key": "chen2023_operating",
     "doi": "10.1109/tmrb.2023.3272049",
     "url": null,
     "title": "The Catheter and Guidewire Operating Systems of Vascular Interventional Surgical Robots: A Systematic Review",
     "year": 2023,
     "venue": "IEEE Transactions on Medical Robotics and Bionics"
    },
    {
     "key": "miyachi2025_robotics",
     "doi": "10.5797/jnet.ra.2024-0112",
     "url": null,
     "title": "Robotics for Neuroendovascular Therapy",
     "year": 2025,
     "venue": "Journal of Neuroendovascular Therapy"
    },
    {
     "key": "hansen2016_magellan_BROCHURE",
     "doi": null,
     "url": null,
     "title": "Magellan Robotic System brochure (LT0040 Rev C)",
     "year": 2012,
     "venue": null
    }
   ],
   "read_level": "abstract",
   "read_level_detail": "brochure (full, hansen2016_magellan_BROCHURE); abstract (S8)",
   "notes": "Withdrawn after Auris acquisition (2019 per mandhumula2025_robotic; the same source also says 2016). | X2 2026-11-08: Magellan brochure read in full: no numbers beyond cited studies (Bismuth 2011 first-in-man iliofemoral, Riga 2010/2011).",
   "maintainers_own": false,
   "found_by": "commercial"
  },
  {
   "schema_version": 1,
   "id": "amigo_catheterrobotics2008",
   "name": "Amigo",
   "full_name": "Amigo Remote Catheter System",
   "group": "Catheter Robotics, now Catheter Precision (VTAK)",
   "group_short": "Catheter Robotics",
   "family": "commercial",
   "category": "commercial",
   "first_year": 2008,
   "latest_year": 2026,
   "versions": "single",
   "target_anatomy": "cardiac EP (mapping)",
   "devices": [
    "catheter",
    "sheath"
   ],
   "devices_driven": "one standard steerable EP catheter handle (Boston Scientific Blazer or Biosense Webster EZ Steer orientation, docking station specific to the catheter type); no proprietary catheters, introducers or sheaths (catheterrobotics2020_amigo_BROCHURE pp. 3, 7)",
   "n_dof": 3,
   "n_dof_detail": "3 (insert/withdraw, continuous 360-degree rotation, bidirectional deflection) (brochure p. 5)",
   "translation_mechanism": "other",
   "translation_detail": "other: mechanical cradle moving catheter handle",
   "rotation_mechanism": "handle-rotation",
   "rotation_detail": "cradle",
   "device_range": "linear translation < 12 +- 2 mm/s; linear resolution < 1.6 mm; rotation resolution < 1.1 deg; rotation max < 0.42 rev/s; articulation resolution 1.0% full scale; articulation max 0.48 rev/s (brochure p. 3)",
   "footprint_mm": "1016 x 1372 x 1118 mm (H x W x D; converted by X2 from 40 x 54 x 44 in as listed, whole robot) (brochure p. 3)",
   "mass_kg": "approx. 70 lb = 31.8 kg (converted by X2) (brochure p. 3)",
   "force_sensing": "none (used with contact-force catheters)",
   "haptics_leader": "no: handheld remote controller like a catheter handle (rotation knob, deflection knob, insert and withdraw buttons), up to 100 ft away (brochure p. 5)",
   "imaging_compat": "uses existing EP-lab monitors and workstations, no room rebuild (brochure p. 3)",
   "sterility": "disposable kit: drapes over the sides and top, nosecone to the introducer, catheter track, docking station and spreader form the sterile interface (brochure p. 7)",
   "highest_validation": "human",
   "validation_detail": "IDE trial NCT01139814: 206 patients enrolled at 13 centres, 8 pre-specified locations each, 1,448 locations mapped (brochure p. 1); 181-pt analysis 1,396/1,448 (96%) (PMC7252924 via search, not opened)",
   "key_numbers": "efficacy 96% (97% adjusted for missing source data; 99% with fluoroscopic confirmation only); responder success (6 of 8 locations) 98%; mean manipulation time 45 s per location, falling significantly by the 3rd case; no major complications, no perforations (brochure p. 1); FDA K122488 (2012): manipulation of diagnostic catheters in RA/RV only, ablation not established (510k.innolitics via search summary)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "A",
    "kind": "product-photo",
    "source": "catheterrobotics2020_amigo_BROCHURE (Catheter Robotics \"Amigo Remote Catheter System\" product sheet 82-1012-001 Rev1, (c) 2012), p. 3 embedded image (5616 x 3744; the page shows only a clipped part of it),",
    "source_url": null,
    "licence": "press image (Catheter Robotics brochure)",
    "credit": "Catheter Robotics, 2012. press image (Catheter Robotics brochure).",
    "edits": "native extract; cropped (0,520)-(5616,3744) to drop a lamp reflection at the top; nothing erased; none upscaled; no tone change",
    "file": null
   },
   "pictures": [
    {
     "id": "amigo_catheterrobotics2008_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Amigo handheld remote controller held in the operator's hand",
     "source_key": "chen2023_operating",
     "source": "Chen et al., IEEE Transactions on Medical Robotics and Bionics (2023), Fig. 8(e), p. 7",
     "source_url": "https://doi.org/10.1109/tmrb.2023.3272049",
     "where": "Fig. 8(e), p. 7",
     "licence": "publisher copyright"
    },
    {
     "id": "amigo_catheterrobotics2008_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Amigo under its sterile drape on the table of an EP laboratory",
     "source_key": "catheterrobotics2020_amigo_BROCHURE",
     "source": "Catheter Robotics (2012), brochure \"Amigo in Clinical Use\" (82-0100-005 Rev1), p. 1 (embedded image)",
     "source_url": null,
     "where": "brochure \"Amigo in Clinical Use\" (82-0100-005 Rev1), p. 1 (embedded image)",
     "licence": "press image"
    },
    {
     "id": "amigo_catheterrobotics2008_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Handheld remote controller with rotation knob, deflection knob and insert/withdraw buttons",
     "source_key": "catheterrobotics2020_amigo_BROCHURE",
     "source": "Catheter Robotics (2012), brochure \"Controller\" sheet (82-8020-001 Rev1), p. 5 (embedded image)",
     "source_url": null,
     "where": "brochure \"Controller\" sheet (82-8020-001 Rev1), p. 5 (embedded image)",
     "licence": "press image"
    },
    {
     "id": "amigo_catheterrobotics2008_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Disposable docking station and track that hold the catheter handle",
     "source_key": "catheterrobotics2020_amigo_BROCHURE",
     "source": "Catheter Robotics (2012), brochure \"Disposable Kit\" sheet (82-2000-001 Rev01), p. 7 (embedded image)",
     "source_url": null,
     "where": "brochure \"Disposable Kit\" sheet (82-2000-001 Rev01), p. 7 (embedded image)",
     "licence": "press image"
    }
   ],
   "sources": [
    {
     "key": "rafiitari2014_current",
     "doi": "10.1007/s10439-013-0946-8",
     "url": null,
     "title": "Current and Emerging Robot-Assisted Endovascular Catheterization Technologies: A Review",
     "year": 2014,
     "venue": "Annals of Biomedical Engineering"
    },
    {
     "key": "li2024_design",
     "doi": "10.1109/tmrb.2024.3377374",
     "url": null,
     "title": "Robotic Systems Design in Endovascular Treatment",
     "year": 2024,
     "venue": "IEEE Transactions on Medical Robotics and Bionics"
    },
    {
     "key": "chen2026_teleoperation",
     "doi": "10.1109/TMRB.2026.3681030",
     "url": null,
     "title": "Remote Teleoperation of Endovascular Intervention Robots: A Systematic Review",
     "year": 2026,
     "venue": "IEEE Transactions on Medical Robotics and Bionics"
    },
    {
     "key": "catheterrobotics2020_amigo_BROCHURE",
     "doi": null,
     "url": null,
     "title": "Amigo Remote Catheter System brochure (Amigo in Clinical Use; Technical Specifications; Controller; Disposable Kit)",
     "year": 2012,
     "venue": null
    }
   ],
   "read_level": "web",
   "read_level_detail": "brochure (full, catheterrobotics2020_amigo_BROCHURE); web",
   "notes": "Transcontinental in-vitro remote demo (Serafini 2022, 3,380 km, chen2026_teleoperation Table I). Company still lists Amigo as an IP asset in FY2025 (aggregator). | X2 2026-11-08: Amigo brochure (Catheter Robotics, (c) 2012) read in full; the main picture is now its studio product photo. | X4 2026-11-08: footprint cell reordered so the mm triple comes first (the volume parsers read the first A x B x C as mm)",
   "maintainers_own": false,
   "found_by": "commercial"
  },
  {
   "schema_version": 1,
   "id": "navion_nanoflex2025",
   "name": "Navion",
   "full_name": "Nanoflex magnetic telerobotic platform (Navion per S8)",
   "group": "Nanoflex Robotics (ETH Zurich spin-off, 2021)",
   "group_short": "Nanoflex Robotics",
   "family": "commercial",
   "category": "magnetic-navigation",
   "first_year": 2023,
   "latest_year": 2026,
   "versions": "N.R.",
   "target_anatomy": "stroke (remote thrombectomy), coronary",
   "devices": [
    "guidewire",
    "catheter"
   ],
   "devices_driven": "0.035-in magnetic guidewire; catheter",
   "n_dof": null,
   "n_dof_detail": "tip direction by field vector + advance of two devices",
   "translation_mechanism": "magnetic",
   "translation_detail": "magnetic",
   "rotation_mechanism": "magnetic-field",
   "rotation_detail": "magnetic (mobile 3-electromagnet field generator)",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "none",
   "haptics_leader": "no",
   "imaging_compat": "mobile field generator compatible with C-arm",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "7,000 km in-vitro coronary angiography, 260 runs, latency 134-143 ms (madder2025_transatlantic via S8); CTO reports 100% navigation + clot retrieval (magneticsmag, web)",
   "key_numbers": "no first-in-human found; FIH/FDA submission once planned for Q3 2023 (slipped)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "render",
    "source": "frame t = 5.0 s of https://nanoflexrobotics.com/wp-content/uploads/2024/01/home.mp4 (1280x720, home-page video)",
    "source_url": "https://nanoflexrobotics.com/wp-content/uploads/2024/01/home.mp4",
    "licence": "press image (Nanoflex Robotics)",
    "credit": "frame t = 5.0 s of https://nanoflexrobotics.com/wp-content/uploads/2024/01/home.mp4 (1280x720, home-page video). Licence: press image (Nanoflex Robotics).",
    "edits": "ffmpeg still at 5.0 s, cropped (300,20)-(1100,700)",
    "file": null
   },
   "pictures": [
    {
     "id": "navion_nanoflex2025_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Remote operator at the Nanoflex console in Zurich during the transatlantic study",
     "source_key": "web:nanoflexrobotics.com",
     "source": "nanoflexrobotics.com, (post 2025-08-14, first transatlantic remote animal thrombectomy)",
     "source_url": "https://nanoflexrobotics.com/wp-content/uploads/2025/08/NFX_2-scaled.png",
     "where": "https://nanoflexrobotics.com/wp-content/uploads/2025/08/NFX_2-scaled.png (post 2025-08-14, first transatlantic remote animal thrombectomy)",
     "licence": "press image"
    },
    {
     "id": "navion_nanoflex2025_02",
     "status": "cleared",
     "file": "pictures/extra/navion_nanoflex2025_02.jpg",
     "thumb": "pictures/thumbs/navion_nanoflex2025_02.jpg",
     "kind": "setup",
     "caption": "Electromagnetic navigation system beside the procedure table and C-arm in Zurich",
     "source_key": "madder2025_transatlantic",
     "source": "Madder et al., JACC: Advances (2025), Fig. 1 (left), PMC11719301",
     "source_url": "https://doi.org/10.1016/j.jacadv.2024.101456",
     "where": "Fig. 1 (left), PMC11719301",
     "licence": "CC BY 4.0"
    },
    {
     "id": "navion_nanoflex2025_03",
     "status": "cleared",
     "file": "pictures/extra/navion_nanoflex2025_03.jpg",
     "thumb": "pictures/thumbs/navion_nanoflex2025_03.jpg",
     "kind": "leader",
     "caption": "Gamepad controller with labelled catheter, guidewire and field-steering inputs",
     "source_key": "madder2025_transatlantic",
     "source": "Madder et al., JACC: Advances (2025), Fig. 1 (right), PMC11719301",
     "source_url": "https://doi.org/10.1016/j.jacadv.2024.101456",
     "where": "Fig. 1 (right), PMC11719301",
     "licence": "CC BY 4.0"
    }
   ],
   "sources": [
    {
     "key": "madder2025_transatlantic",
     "doi": "10.1016/j.jacadv.2024.101456",
     "url": null,
     "title": "Transatlantic Telerobotic Coronary Angiography",
     "year": 2025,
     "venue": "JACC: Advances"
    },
    {
     "key": "george2025_robot",
     "doi": "10.1016/j.jscai.2025.102568",
     "url": null,
     "title": "Robot-Assisted Cardiovascular Interventions",
     "year": 2025,
     "venue": "Journal of the Society for Cardiovascular Angiography & Interventions"
    }
   ],
   "read_level": "web",
   "read_level_detail": "web",
   "notes": "The name Navion was not found in any 2026 source I opened (search found nothing for \"Navion\"); S8 carries it from a paper. Treat the name as unverified.",
   "maintainers_own": false,
   "found_by": "commercial"
  },
  {
   "schema_version": 1,
   "id": "allvas_aopeng2021",
   "name": "ALLVAS",
   "full_name": "ALLVAS (REIS)",
   "group": "Aopeng Medical with Shanghai Changhai Hospital (Qingsheng Lu) and Shanghai Jiao Tong University (Kundong Wang) (song2022_biomimetic affiliations; company not named there)",
   "group_short": "Aopeng Medical",
   "family": "commercial",
   "category": "clinical-stage",
   "first_year": 2021,
   "latest_year": 2026,
   "versions": "ALLVAS; predecessor: the group's first-generation robot ('similar to the first-generation surgical robot initially studied by our research group', song2022_biomimetic p. 14, refs 13-14 = Wang 2018 IJMRCAS 14:e1915 and Lu 2020 VES 54:598-604; not read) -> 2022 biomimetic system, 38 porcine cases (song2022_biomimetic; robot unnamed there, identified as ALLVAS by song2023_novel, which cites it) -> 2023 EVAR in patients (song2023_novel); 2022: Changhai (Q. Lu) remote-controlled robot driven by hollow ultrasonic motors, ex vivo phantom (Lu 2022) (Alekseeva 2025 Table 7 row 1, Fig. 13e; Belikov 2024 Fig. 6 QIN) (alekseeva2025_design; belikov2024_evolution)",
   "target_anatomy": "aortic (EVAR), peripheral, coronary (one remote PCI)",
   "devices": [
    "guidewire",
    "catheter",
    "therapeutic-device"
   ],
   "devices_driven": "four manipulators with double V-grippers handle devices from a 0.014-in (0.36 mm) guidewire to a 40 mm stent-graft system (song2022_biomimetic p. 5); 2-3 devices at once in the porcine cases (catheter + guidewire, or stent-graft system, inner core and guidewire in TEVAR) (p. 10); up to 4 devices (song2023_novel); compatible with market devices",
   "n_dof": 18,
   "n_dof_detail": "18 (slave: two three-axis arms and four manipulators, each manipulator with two DC motors and a stepper; song2022_biomimetic p. 4, 7); '12-DOF motion in the four directions of the short axis' (p. 14); 12 per mandhumula2025_robotic as REIS",
   "translation_mechanism": "clamp-relay",
   "translation_detail": "clamp-relay",
   "rotation_mechanism": "rotating-clamp",
   "rotation_detail": "rotatable V-grippers, continuous progressive rotation with relay gripper (song2023_novel)",
   "device_range": "max axial speed 275 mm/s, min 5.15 mm/s, max thrust 27.45 N, max displacement 140 cm (song2022_biomimetic Table 1); rotation speeds 1.57 and 0.52 rad/s (p. 7)",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "force feedback; force sensor on the manipulator (type N.R.), in vitro feedback delay < 60 ms, peak error 0.15 N (song2022_biomimetic p. 8); automatic mode halts above 2 N (liang2025_unleashing)",
   "haptics_leader": "joysticks on a console outside the cath lab: button = clamp/release, knob = rotate, swing = advance/retract; force-feedback handle based on electromagnetic resistance (song2022_biomimetic p. 3, 7, 14; the paper says both 'four joysticks' and 'two sets of master joysticks')",
   "imaging_compat": "mobile base, arm + manipulator",
   "sterility": "detachable grippers, aimed at replacing all contact parts (song2022_biomimetic abstract, p. 14); single-use status N.R.",
   "highest_validation": "human",
   "validation_detail": "EVAR 5 pts (song2023_novel); 4 pts programmed steps (liang2025_unleashing); 1 remote PCI 800 km (Xu 2024); animal: 10 domestic swine (45 kg), 38 robotic cases (PCI 8, TEVAR 4, renal stent 8, iliac stent 10, IVC filter 8), 5 surgeons, plus a 3D-printed aorto-iliac model (song2022_biomimetic p. 9-12)",
   "key_numbers": "EVAR 5/5, operator dose -96.5% (song2023_novel abstract); remote PCI latency 30 ms, 800 km (chen2026_teleoperation Table I); swine: all technically successful, no adverse events, PCI operator dose 24.6 +- 2.72 uGy robotic vs 2224 +- 92.5 manual (the manual operator values equal the manual patient values in every column, possibly a table error), operative time not different, device exchange within 10 s, rotation accuracy 1 degree (song2022_biomimetic Table 2, p. 14)",
   "sim_model": "yes for vessels/wire: SOFA-based training platform of Tongji group (yao2025_sim4endor, full); no model of the robot itself found",
   "has_sim_model": true,
   "sim2real": "yes",
   "sim2real_detail": "YES: chen2026_learning (SAC + MPC filter, sim 49/50 -> phantom 18/20, full, IROS 2026); tian2026_visionlanguage (phantom 30/30, full); Tongji group lists 7 papers on ALLVAS/SOFA (S7b.md); liu2024_autonomous trained on robot not sim",
   "picture": {
    "status": "cleared",
    "grade": "C",
    "kind": "photo",
    "source": "tian2026_visionlanguage (arXiv 2606.30698) Fig. 3(a), native image xref 313 with the authors' soft mask, p5",
    "source_url": "https://arxiv.org/abs/2606.30698",
    "licence": "CC BY 4.0 (both arXiv licences checked on arxiv.org/abs)",
    "credit": "Tian et al., 2026, Fig. 3(a). CC BY 4.0 (both arXiv licences checked on arxiv.org/abs).",
    "edits": "full native image 777x690 with the authors' alpha, flattened on white; cut = authors' alpha (no SAM)",
    "file": "pictures/allvas_aopeng2021.jpg"
   },
   "pictures": [
    {
     "id": "allvas_aopeng2021_01",
     "status": "cleared",
     "file": "pictures/extra/allvas_aopeng2021_01.jpg",
     "thumb": "pictures/thumbs/allvas_aopeng2021_01.jpg",
     "kind": "close-up",
     "caption": "Draped mechanical arms carrying the rotatable gripper relays",
     "source_key": "chen2026_learning",
     "source": "Chen et al. (2026), Fig. 2, arXiv p. 3",
     "source_url": "https://arxiv.org/abs/2607.00066",
     "where": "Fig. 2, arXiv p. 3",
     "licence": "CC BY 4.0"
    },
    {
     "id": "allvas_aopeng2021_02",
     "status": "cleared",
     "file": "pictures/extra/allvas_aopeng2021_02.jpg",
     "thumb": "pictures/thumbs/allvas_aopeng2021_02.jpg",
     "kind": "render",
     "caption": "Functional unit: renderings and a photograph beside the angiography table",
     "source_key": "song2023_novel",
     "source": "Song et al., European Radiology (2023), Fig. 1, p. 3",
     "source_url": "https://doi.org/10.1007/s00330-023-09810-x",
     "where": "Fig. 1, p. 3",
     "licence": "CC BY 4.0"
    },
    {
     "id": "allvas_aopeng2021_03",
     "status": "cleared",
     "file": "pictures/extra/allvas_aopeng2021_03.jpg",
     "thumb": "pictures/thumbs/allvas_aopeng2021_03.jpg",
     "kind": "leader",
     "caption": "Rendering of the interventional console with monitors and control panels",
     "source_key": "song2023_novel",
     "source": "Song et al., European Radiology (2023), Fig. 2, p. 3",
     "source_url": "https://doi.org/10.1007/s00330-023-09810-x",
     "where": "Fig. 2, p. 3",
     "licence": "CC BY 4.0"
    },
    {
     "id": "allvas_aopeng2021_04",
     "status": "cleared",
     "file": "pictures/extra/allvas_aopeng2021_04.jpg",
     "thumb": "pictures/thumbs/allvas_aopeng2021_04.jpg",
     "kind": "close-up",
     "caption": "Renderings of the grippers rotating through four motion states",
     "source_key": "song2023_novel",
     "source": "Song et al., European Radiology (2023), Fig. 5, p. 8",
     "source_url": "https://doi.org/10.1007/s00330-023-09810-x",
     "where": "Fig. 5, p. 8",
     "licence": "CC BY 4.0"
    },
    {
     "id": "allvas_aopeng2021_05",
     "status": "cleared",
     "file": "pictures/extra/allvas_aopeng2021_05.jpg",
     "thumb": "pictures/thumbs/allvas_aopeng2021_05.jpg",
     "kind": "render",
     "caption": "Rendering of the two mechanical arms with gripper ends",
     "source_key": "tian2026_visionlanguage",
     "source": "Tian et al. (2026), Fig. 3(b), arXiv p. 5",
     "source_url": "https://arxiv.org/abs/2606.30698",
     "where": "Fig. 3(b), arXiv p. 5",
     "licence": "CC BY 4.0"
    },
    {
     "id": "allvas_aopeng2021_06",
     "status": "cleared",
     "file": "pictures/extra/allvas_aopeng2021_06.jpg",
     "thumb": "pictures/thumbs/allvas_aopeng2021_06.jpg",
     "kind": "render",
     "caption": "Bionic design: two three-axis arms with four manipulators and grippers (labelled)",
     "source_key": "song2022_biomimetic",
     "source": "Song et al., Micromachines (2022), Fig. 2(a-c), p. 4",
     "source_url": "https://doi.org/10.3390/mi13101587",
     "where": "Fig. 2(a-c), p. 4",
     "licence": "CC BY 4.0"
    },
    {
     "id": "allvas_aopeng2021_07",
     "status": "cleared",
     "file": "pictures/extra/allvas_aopeng2021_07.jpg",
     "thumb": "pictures/thumbs/allvas_aopeng2021_07.jpg",
     "kind": "close-up",
     "caption": "Rendering of the coaxial manipulators clamping a stent-graft system",
     "source_key": "song2022_biomimetic",
     "source": "Song et al., Micromachines (2022), Fig. 3(b), p. 6",
     "source_url": "https://doi.org/10.3390/mi13101587",
     "where": "Fig. 3(b), p. 6",
     "licence": "CC BY 4.0"
    },
    {
     "id": "allvas_aopeng2021_08",
     "status": "cleared",
     "file": "pictures/extra/allvas_aopeng2021_08.jpg",
     "thumb": "pictures/thumbs/allvas_aopeng2021_08.jpg",
     "kind": "in-use",
     "caption": "Robot grippers at the table beside the angiograms of five porcine procedure types",
     "source_key": "song2022_biomimetic",
     "source": "Song et al., Micromachines (2022), Fig. 8(a-e), p. 13",
     "source_url": "https://doi.org/10.3390/mi13101587",
     "where": "Fig. 8(a-e), p. 13",
     "licence": "CC BY 4.0"
    }
   ],
   "sources": [
    {
     "key": "song2023_novel",
     "doi": "10.1007/s00330-023-09810-x",
     "url": null,
     "title": "A novel endovascular robotic-assisted system for endovascular aortic repair: first-in-human evaluation of practicability and safety",
     "year": 2023,
     "venue": "European Radiology"
    },
    {
     "key": "song2022_biomimetic",
     "doi": "10.3390/mi13101587",
     "url": null,
     "title": "Novel Endovascular Interventional Surgical Robotic System Based on Biomimetic Manipulation",
     "year": 2022,
     "venue": "Micromachines"
    },
    {
     "key": "liang2025_unleashing",
     "doi": "10.1002/mco2.70489",
     "url": null,
     "title": "Unleashing the Potential: First-in-Human Evaluation of Automatic Robotic-Assisted Endovascular Aortic Repair for Standardized Therapies",
     "year": 2025,
     "venue": "MedComm"
    },
    {
     "key": "chen2026_teleoperation",
     "doi": "10.1109/TMRB.2026.3681030",
     "url": null,
     "title": "Remote Teleoperation of Endovascular Intervention Robots: A Systematic Review",
     "year": 2026,
     "venue": "IEEE Transactions on Medical Robotics and Bionics"
    },
    {
     "key": "chen2026_learning",
     "doi": null,
     "url": "https://arxiv.org/abs/2607.00066",
     "title": "Learning Expert Strategy for Autonomous Robotic Endovascular Intervention via Decoupled Procedural Execution",
     "year": 2026,
     "venue": null
    },
    {
     "key": "tian2026_visionlanguage",
     "doi": null,
     "url": "https://arxiv.org/abs/2606.30698",
     "title": "Vision-Language Procedural Reasoning for Context-Aware Reward Modeling of Robotic Endovascular Guidewire Navigation",
     "year": 2026,
     "venue": null
    },
    {
     "key": "liu2024_autonomous",
     "doi": null,
     "url": "https://arxiv.org/abs/2403.05748",
     "title": "Autonomous Guidewire Navigation for Robot-assisted Endovascular Interventions: A Knowledge-Driven Visual Guidance Approach",
     "year": 2024,
     "venue": null
    },
    {
     "key": "alekseeva2025_design",
     "doi": "10.1002/rob.22480",
     "url": null,
     "title": "The Design of Endovascular Robots for Cardiac Interventions: A Survey",
     "year": 2024,
     "venue": "Journal of Field Robotics"
    },
    {
     "key": "belikov2024_evolution",
     "doi": "10.1016/j.jestch.2024.101789",
     "url": null,
     "title": "Evolution and current state of robotic catheters for endovascular surgery: A comprehensive review",
     "year": 2024,
     "venue": "Engineering Science and Technology, an International Journal"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (song2022_biomimetic); partial (S8) for the rest",
   "notes": "NMPA registration not verified. Only commercial-grade robot with simulation-trained controllers on hardware (phantom only). | X2 2026-11-08: song2022 (Micromachines, CC BY 4.0) read in full: 18 DOF (12 was the short-axis count), 38 swine cases.",
   "maintainers_own": false,
   "found_by": "commercial"
  },
  {
   "schema_version": 1,
   "id": "etcath200_wemed2021",
   "name": "ETcath200",
   "full_name": "ETcath / ETcath200",
   "group": "Beijing WeMed Medical (Weimai)",
   "group_short": "WeMed",
   "family": "commercial",
   "category": "commercial",
   "first_year": 2021,
   "latest_year": 2026,
   "versions": "ETcath200",
   "target_anatomy": "coronary (elective PCI low-intermediate risk lesions)",
   "devices": [
    "guidewire",
    "catheter",
    "therapeutic-device"
   ],
   "devices_driven": "guidewire, RX balloon/stent catheter (guidewire arm); guiding catheter advance (catheter arm)",
   "n_dof": null,
   "n_dof_detail": "N.R. as a count",
   "translation_mechanism": "friction-roller",
   "translation_detail": "friction-roller (roller interface per yang2026_feasibility)",
   "rotation_mechanism": "not-reported",
   "rotation_detail": "N.R.",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "guidewire force sensing; claimed resolution 0.01 N (people.cn press)",
   "haptics_leader": "no (visual resistance display; joystick/roller control box)",
   "imaging_compat": "two passive arms on table rails, clear of X-ray equipment",
   "sterility": "single-use sterile cassette kit",
   "highest_validation": "human",
   "validation_detail": "RCT 73 robot vs 79 manual (yu2025_robot); 20 complex lesions (yang2026_feasibility)",
   "key_numbers": "RCT: clinical success 100% both, robot technical success 100%, longer procedure, lower operator dose (yu2025_robot abstract). Complex lesions: 16/20 (80%) technical success, 4 conversions, 61.0+-23.3 min (yang2026_feasibility).",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "A",
    "kind": "render",
    "source": "https://www.we-med.com/uploadfile/202509/2d2d043639daec2.png (WeMed product page 冠脉介入手术控制系统 ETcath200, https://www.we-med.com/index.php?c=show&id=661; the same file is the listing image https://www.we-med.com/uploadfile/202509/5289d21516dd81b.png)",
    "source_url": "https://www.we-med.com/uploadfile/202509/2d2d043639daec2.png",
    "licence": "press image (company product image)",
    "credit": "https://www.we-med.com/uploadfile/202509/2d2d043639daec2.png (WeMed product page 冠脉介入手术控制系统 ETcath200, https://www.we-med.com/index.php?c=show&id=661; the same file is the listing image https://www.we-med.com/uploadfile/202509/5289d21516dd81b.png). Licence: press image (company product image).",
    "edits": "RGBA product render flattened on white; cropped to the drawing with about 4 % margin (0,0)-(1422,1129) of 1422x1182; no erasing; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "etcath200_wemed2021_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Rendering of ETcath200 installed in a cath lab: two passive arms on the table",
     "source_key": "yang2026_feasibility",
     "source": "Yang et al., Catheterization and Cardiovascular Interventions (2026), Fig. 1(A), PMC13043798",
     "source_url": "https://doi.org/10.1002/ccd.70488",
     "where": "Fig. 1(A), PMC13043798",
     "licence": "CC BY-NC-ND 4.0"
    },
    {
     "id": "etcath200_wemed2021_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Operator at the shielded ETcath200 console outside the procedure room",
     "source_key": "yang2026_feasibility",
     "source": "Yang et al., Catheterization and Cardiovascular Interventions (2026), Fig. 1(B), PMC13043798",
     "source_url": "https://doi.org/10.1002/ccd.70488",
     "where": "Fig. 1(B), PMC13043798",
     "licence": "CC BY-NC-ND 4.0"
    },
    {
     "id": "etcath200_wemed2021_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Operator at the ETcath200 console during a robotic procedure at Lanzhou",
     "source_key": "web:chinadaily.com.cn",
     "source": "chinadaily.com.cn, China Daily 2026-05-26 image 1, (story photo supplied by the interviewee)",
     "source_url": "https://cds.chinadaily.com.cn/dams/capital/image/202605/26/6a157fff6b8ed8bf1912651f_m.jpeg",
     "where": "China Daily 2026-05-26 image 1, https://cds.chinadaily.com.cn/dams/capital/image/202605/26/6a157fff6b8ed8bf1912651f_m.jpeg (story https://cn.chinadaily.com.cn/a/202605/26/WS6a158025a310942cc49ae6e9.html; photo supplied by the interviewee)",
     "licence": "press image"
    }
   ],
   "sources": [
    {
     "key": "yu2025_robot",
     "doi": "10.26599/1671-5411.2025.08.008",
     "url": null,
     "title": "Robot-assisted percutaneous coronary intervention: a prospective, multicenter, randomized controlled, non-inferiority clinical trial",
     "year": 2025,
     "venue": "Journal of Geriatric Cardiology"
    },
    {
     "key": "yang2026_feasibility",
     "doi": "10.1002/ccd.70488",
     "url": null,
     "title": "Feasibility and Safety of the ETcath200 Robotic PCI System for Complex Coronary Lesions: A Prospective Single-Center Study",
     "year": 2026,
     "venue": "Catheterization and Cardiovascular Interventions"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full text on disk (yang2026) + web",
   "notes": "NMPA approval reported March 2025 (people.cn 2025-03-25 citing a Beijing E-Town WeChat post; registration number/date not seen). First robotic PCI at Anzhen Oct 2021 (search). WeMed contributed to NMPA standard YY/T 1994-2025 (web). Possible WeMed neuro product (Weimai) status: under review per yicai 2024.",
   "maintainers_own": false,
   "found_by": "commercial"
  },
  {
   "schema_version": 1,
   "id": "aviar_lnrobotics2018",
   "name": "AVIAR 2.0",
   "full_name": "AVIAR 2.0",
   "group": "LN Robotics",
   "group_short": "LN Robotics",
   "family": "commercial",
   "category": "commercial",
   "first_year": 2018,
   "latest_year": 2025,
   "versions": "AVIAR; AVIAR 2.0 (MFDS 2023)",
   "target_anatomy": "coronary",
   "devices": [
    "guidewire",
    "catheter",
    "therapeutic-device"
   ],
   "devices_driven": "multi-channel: guiding catheter fixed, guidewire, balloon/stent catheter via roller block",
   "n_dof": null,
   "n_dof_detail": "N.R.",
   "translation_mechanism": "friction-roller",
   "translation_detail": "friction-roller",
   "rotation_mechanism": "roller-rolling",
   "rotation_detail": "roller block (translation + rotation)",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "N.R.",
   "haptics_leader": "yes (haptic manipulator with control wheel + joystick)",
   "imaging_compat": "robotic positioning arm + IDU",
   "sterility": "N.R.",
   "highest_validation": "human",
   "validation_detail": "20 pts, multicentre (lee2025_safety)",
   "key_numbers": "technical and clinical success 100%; robotic time 23:06+-05:55 min; operator dose -84% (lee2025_safety abstract)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "product-photo",
    "source": "https://img.hankyung.com/photo/202606/AD.44819292.1.jpg (Hankyung Magazine article on LN Robotics, https://magazine.hankyung.com/job-joy/article/202606271488d)",
    "source_url": "https://img.hankyung.com/photo/202606/AD.44819292.1.jpg",
    "licence": "press image (LN Robotics product photo in news article)",
    "credit": "https://img.hankyung.com/photo/202606/AD.44819292.1.jpg (Hankyung Magazine article on LN Robotics, https://magazine.hankyung.com/job-joy/article/202606271488d). Licence: press image (LN Robotics product photo in news article).",
    "edits": "cropped (68,68)-(908,773) of 1000x826; not upscaled; no tone change; no erasing",
    "file": null
   },
   "pictures": [
    {
     "id": "aviar_lnrobotics2018_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Robotic PCI procedure: team preparation, cassette loading and console operation",
     "source_key": "lee2025_safety",
     "source": "Lee et al., Korean Circulation Journal (2025), Fig. 2, PMC12046302",
     "source_url": "https://doi.org/10.4070/kcj.2024.0226",
     "where": "Fig. 2, PMC12046302",
     "licence": "CC BY-NC 4.0"
    },
    {
     "id": "aviar_lnrobotics2018_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Labelled rendering of the physician console and procedure robot with IDU close-up",
     "source_key": "lee2025_safety",
     "source": "Lee et al., Korean Circulation Journal (2025), Fig. 1, PMC12046302",
     "source_url": "https://doi.org/10.4070/kcj.2024.0226",
     "where": "Fig. 1, PMC12046302",
     "licence": "CC BY-NC 4.0"
    }
   ],
   "sources": [
    {
     "key": "lee2025_safety",
     "doi": "10.4070/kcj.2024.0226",
     "url": null,
     "title": "Safety and Feasibility of Robot-Assisted Percutaneous Coronary Intervention Using the AVIAR 2.0 System: A Prospective, Multi-Center, Single-Arm, Open, Investigator-Initiated, Post-Approval Clinical Trial",
     "year": 2025,
     "venue": "Korean Circulation Journal"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full text on disk",
   "notes": "MFDS approval 2023 as stated by lee2025_safety.",
   "maintainers_own": false,
   "found_by": "commercial"
  },
  {
   "schema_version": 1,
   "id": "panvisa_abrobo2024",
   "name": "PANVIS-A",
   "full_name": "PANVIS-A",
   "group": "Shenzhen Institute of Advanced Biomedical Robot (Abrobo, Aibo Hechuang)",
   "group_short": "Abrobo",
   "family": "commercial",
   "category": "commercial",
   "first_year": 2023,
   "latest_year": 2026,
   "versions": "third generation per press reports",
   "target_anatomy": "neurovascular (cerebral angiography)",
   "devices": [
    "guidewire",
    "catheter"
   ],
   "devices_driven": "one 0.035-in guidewire + one 5F angiographic / 6F guiding catheter",
   "n_dof": 2,
   "n_dof_detail": "2 per device",
   "translation_mechanism": "clamp-relay",
   "translation_detail": "clamp-relay",
   "rotation_mechanism": "roller-rolling",
   "rotation_detail": "clamps twist guidewire (thumb-index mimic)",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "N.R.",
   "haptics_leader": "no (master-slave manipulator)",
   "imaging_compat": "slave on DSA table",
   "sterility": "N.R.",
   "highest_validation": "human",
   "validation_detail": "RCT 64 robot vs 66 manual, 4 centres, NCT05778214 (zhang2026_safety)",
   "key_numbers": "success 100% both arms; operator dose 1.67+-3.49 vs 43.63+-38.95 uSv (zhang2026_safety abstract)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "render",
    "source": "zhang2026_safety Fig. 1(A), PMC image https://cdn.ncbi.nlm.nih.gov/pmc/blobs/cc91/13217118/7172c200f078/jnis-18-5-g001.jpg (article page https://pmc.ncbi.nlm.nih.gov/articles/PMC13217118/)",
    "source_url": "https://doi.org/10.1136/jnis-2025-023412",
    "licence": "CC BY-NC 4.0",
    "credit": "Zhang et al., Journal of NeuroInterventional Surgery (2026), Fig. 1. CC BY-NC 4.0.",
    "edits": "cropped (0,0)-(305,192) of 684x390 (panel A, above the panel letter); not upscaled; no tone change; no erasing",
    "file": null
   },
   "pictures": [
    {
     "id": "panvisa_abrobo2024_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Rendering of the bedside unit on the table beside the C-arm, with console",
     "source_key": "zhang2026_safety",
     "source": "Zhang et al., Journal of NeuroInterventional Surgery (2026), Fig. 1(B), PMC13217118",
     "source_url": "https://doi.org/10.1136/jnis-2025-023412",
     "where": "Fig. 1(B), PMC13217118",
     "licence": "CC BY-NC 4.0"
    },
    {
     "id": "panvisa_abrobo2024_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Operator using the PANVIS-A console joystick in front of the angiography display",
     "source_key": "zhang2026_safety",
     "source": "Zhang et al., Journal of NeuroInterventional Surgery (2026), Fig. 1(D), PMC13217118",
     "source_url": "https://doi.org/10.1136/jnis-2025-023412",
     "where": "Fig. 1(D), PMC13217118",
     "licence": "CC BY-NC 4.0"
    },
    {
     "id": "panvisa_abrobo2024_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Rendering of the PANVIS-A console with touch screen and joysticks",
     "source_key": "zhang2026_safety",
     "source": "Zhang et al., Journal of NeuroInterventional Surgery (2026), Fig. 1(C), PMC13217118",
     "source_url": "https://doi.org/10.1136/jnis-2025-023412",
     "where": "Fig. 1(C), PMC13217118",
     "licence": "CC BY-NC 4.0"
    },
    {
     "id": "panvisa_abrobo2024_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "In vivo test: slave robot over the animal, master controller, gantry",
     "source_key": "cao2024_reciprocating",
     "source": "Cao et al., IEEE Transactions on Instrumentation and Measurement (2024), Fig. 15, p. 10 (lineage paper, Guo group)",
     "source_url": "https://doi.org/10.1109/tim.2023.3342853",
     "where": "Fig. 15, p. 10 (lineage paper, Guo group)",
     "licence": "publisher copyright"
    },
    {
     "id": "panvisa_abrobo2024_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Manipulator C in its sterile box, with snapshots of the clamp opening",
     "source_key": "cao2024_reciprocating",
     "source": "Cao et al., IEEE Transactions on Instrumentation and Measurement (2024), Fig. 5, p. 5",
     "source_url": "https://doi.org/10.1109/tim.2023.3342853",
     "where": "Fig. 5, p. 5",
     "licence": "publisher copyright"
    },
    {
     "id": "panvisa_abrobo2024_06",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Function diagram: slave actuators, radiation-protected console, gantry and master handles",
     "source_key": "cao2024_reciprocating",
     "source": "Cao et al., IEEE Transactions on Instrumentation and Measurement (2024), Fig. 1, p. 2",
     "source_url": "https://doi.org/10.1109/tim.2023.3342853",
     "where": "Fig. 1, p. 2",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "zhang2026_safety",
     "doi": "10.1136/jnis-2025-023412",
     "url": null,
     "title": "Safety and efficacy of cerebral robot assisted angiography: randomized comparison of robotic versus manual procedures",
     "year": 2026,
     "venue": "Journal of NeuroInterventional Surgery"
    },
    {
     "key": "cao2024_reciprocating",
     "doi": "10.1109/tim.2023.3342853",
     "url": null,
     "title": "A Reciprocating Delivery Device-Based Endovascular Intervention Robot With Multimanipulators Collaboration",
     "year": 2024,
     "venue": "IEEE Transactions on Instrumentation and Measurement"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full text on disk",
   "notes": "NMPA Class III 2024-08-26 (company release; yicai says Aibo Hechuang was the only interventional robot to get a certificate in 2024, indication angiography only, not treatment).",
   "maintainers_own": false,
   "found_by": "commercial"
  },
  {
   "schema_version": 1,
   "id": "ydhbns01_yidu2020",
   "name": "VAS HERO",
   "full_name": "YDHB-NS01 / VAS HERO",
   "group": "Yidu Hebei Robot Technology",
   "group_short": "Yidu Hebei",
   "family": "commercial",
   "category": "commercial",
   "first_year": 2020,
   "latest_year": 2026,
   "versions": "YDHB-NS01; v2.0 mentioned",
   "target_anatomy": "neurovascular (cerebral angiography)",
   "devices": [
    "guidewire",
    "catheter"
   ],
   "devices_driven": "0.035-in guidewire + 5F catheter",
   "n_dof": null,
   "n_dof_detail": "catheter advance+rotate, wire advance",
   "translation_mechanism": "linear-stage+clamp",
   "translation_detail": "linear-stage+clamp",
   "rotation_mechanism": "not-reported",
   "rotation_detail": "catheter carriage on linear axis; wire clamp-and-relay",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "N.R.",
   "haptics_leader": "no (steering handles, doctor console)",
   "imaging_compat": "bedside slave + remote console",
   "sterility": "N.R.",
   "highest_validation": "human",
   "validation_detail": "RCT 260 enrolled/257 done, 3 centres (liu2024_efficacy); 25+25 (liu2026_clinical)",
   "key_numbers": "success 100% both; operation time 47.94+-27.49 vs 48.59+-25.60 min (liu2024_efficacy); 27 vs 38 min p=0.005 (liu2026_clinical)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "render",
    "source": "liu2024_efficacy Fig. 2(B), PMC image https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ca6f/11221321/099807b86682/svn-2022-002260f02.jpg (https://pmc.ncbi.nlm.nih.gov/articles/PMC11221321/)",
    "source_url": "https://doi.org/10.1136/svn-2022-002260",
    "licence": "CC BY-NC 4.0",
    "credit": "Liu et al., Stroke and Vascular Neurology (2024), Fig. 2. CC BY-NC 4.0.",
    "edits": "cropped (422,0)-(783,228) of 783x574",
    "file": null
   },
   "pictures": [
    {
     "id": "ydhbns01_yidu2020_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "System rendering with callouts: disposables, operating arm, cabinet, workstation",
     "source_key": "liu2024_efficacy",
     "source": "Liu et al., Stroke and Vascular Neurology (2024), Fig. 2(A), PMC11221321",
     "source_url": "https://doi.org/10.1136/svn-2022-002260",
     "where": "Fig. 2(A), PMC11221321",
     "licence": "CC BY-NC 4.0"
    },
    {
     "id": "ydhbns01_yidu2020_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Operator at the workstation driving the robot with joystick and touch panel",
     "source_key": "liu2024_efficacy",
     "source": "Liu et al., Stroke and Vascular Neurology (2024), Fig. 2(D), PMC11221321",
     "source_url": "https://doi.org/10.1136/svn-2022-002260",
     "where": "Fig. 2(D), PMC11221321",
     "licence": "CC BY-NC 4.0"
    }
   ],
   "sources": [
    {
     "key": "liu2024_efficacy",
     "doi": "10.1136/svn-2022-002260",
     "url": null,
     "title": "Efficacy and safety of a neurointerventional operation robotic assistance system in cerebral angiography",
     "year": 2024,
     "venue": "Stroke and Vascular Neurology"
    },
    {
     "key": "liu2026_clinical",
     "doi": "10.1186/s41016-026-00426-w",
     "url": null,
     "title": "Clinical validation and literature review of robot-assisted cerebral angiography",
     "year": 2026,
     "venue": "Chinese Neurosurgical Journal"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full text on disk",
   "notes": "NMPA Class III approval 2023-03-13 per cn-healthcare.com 2023-04-28 (named 易度河北, product VAS HERO). CONFLICT: other press attributes the first NMPA approval (2023-03-14, 260-pt, 100% success) to Beijing Wansi (万思) Medical; the 260-pt 3-centre trial matches liu2024_efficacy (YDHB-NS01), so Wansi attribution looks like a mix-up; unresolved without the NMPA database.",
   "maintainers_own": false,
   "found_by": "commercial"
  },
  {
   "schema_version": 1,
   "id": "rational_denova2023",
   "name": "RATIONAL",
   "full_name": "RATIONAL",
   "group": "Hangzhou Denova (Dinova) Neuro Medtech, 杭州德诺脑神经医疗科技有限公司; co-developed with Beijing Tiantan Hospital (Gao Feng team)",
   "group_short": "Denova Medtech",
   "family": "commercial",
   "category": "clinical-stage",
   "first_year": 2023,
   "latest_year": 2026,
   "versions": "RATIONAL surgical control system (company promo); registered as Cerebrovascular Interventional Procedural Control System (NCT05972252)",
   "target_anatomy": "neurovascular (mechanical thrombectomy, anterior circulation)",
   "devices": [
    "guidewire",
    "microcatheter",
    "catheter",
    "therapeutic-device"
   ],
   "devices_driven": "4: microguidewire, microcatheter, aspiration catheter, stent retriever; guide/aspiration catheters inserted manually",
   "n_dof": null,
   "n_dof_detail": "N.R.",
   "translation_mechanism": "not-reported",
   "translation_detail": "N.R.",
   "rotation_mechanism": "not-reported",
   "rotation_detail": "N.R.",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "N.R.",
   "haptics_leader": "N.R. (three joysticks)",
   "imaging_compat": "console outside room",
   "sterility": "preloaded single-use cassette (DNNSJ07-IR)",
   "highest_validation": "human",
   "validation_detail": "10 pts first-in-human, Beijing Tiantan, Oct 2023-Jun 2024 (yang2025_use); trial NCT05972252, start 2023-10-15, Beijing Tiantan Hospital (clinicaltrials2023_nct05972252)",
   "key_numbers": "mTICI 3 in 8, 2b in 2; puncture-to-reperfusion 65.10+-22.23 min (robotic 13.70+-5.18, manual 51.40+-20.16); console dose 0.18+-0.11 vs 59.21+-52.57 uSv; 90-day mRS<=2 in 7; technician device exchange = main limitation",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "render",
    "source": "https://medtion-image.medtion.com/pgc/20250409/8911cefa18e30db24504d880554b0cca. (857 x 408 company promo image, 'RATIONAL 手术控制系统' + '配套耗材'), page https://www.brainmed.com/info/detail?id=51164 (脑医汇 2025-04-09, reposted from WeChat 神经介入在线); same pixels as the author's screenshot figures/raw/web/rational_user_promo.png",
    "source_url": "https://medtion-image.medtion.com/pgc/20250409/8911cefa18e30db24504d880554b0cca",
    "licence": "news/company image, publisher copyright",
    "credit": "https://medtion-image.medtion.com/pgc/20250409/8911cefa18e30db24504d880554b0cca. (857 x 408 company promo image, 'RATIONAL 手术控制系统' + '配套耗材'), page https://www.brainmed.com/info/detail?id=51164 (脑医汇 2025-04-09, reposted from WeChat 神经介入在线); same pixels as the author's screenshot figures/raw/web/rational_user_promo.png. Licence: news/company image, publisher copyright.",
    "edits": "RGBA composited on white; 2 orange leader lines on the plain white background (neither touches the robot) painted white by colour mask + 2 px dilation; 2 text blocks on plain white painted white (right: 2 lines of claims; left: end of the consumables text); fragments of the consumables graphic at the left edge (stent-retriever tip, tube end) painted white; cropped to the robot and table (about 22 px margin; the pedestal is cut by the original's bottom border); no inpainting model; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "rational_denova2023_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Whole system: table-mounted arm with drive heads, aspiration pump, console with three joysticks and touch panel, monitors (labelled figure panel)",
     "source_key": "web:brainmed.com/info/detail?id=51164",
     "source": "brainmed.com/info/detail?id=51164, article image (panel 'a', labels A1/A2/D1/D2; original publication not stated)",
     "source_url": "https://medtion-image.medtion.com/pgc/20250409/27f5f82e1f1cb5273e45415a14170b14",
     "where": "article image https://medtion-image.medtion.com/pgc/20250409/27f5f82e1f1cb5273e45415a14170b14. (panel 'a', labels A1/A2/D1/D2; original publication not stated)",
     "licence": "news/company image, publisher copyright"
    },
    {
     "id": "rational_denova2023_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Tiantan team in the angiography suite; the draped robot on the table at the right",
     "source_key": "web:brainmed.com/info/detail?id=51164",
     "source": "brainmed.com/info/detail?id=51164, article image",
     "source_url": "https://medtion-image.medtion.com/pgc/20250409/d2ed8b793d2329e0426a1946720532b7",
     "where": "article image https://medtion-image.medtion.com/pgc/20250409/d2ed8b793d2329e0426a1946720532b7.",
     "licence": "news/company image, publisher copyright"
    },
    {
     "id": "rational_denova2023_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Company promo image: the robot on the table with its matched consumables (stent retriever, microcatheter, support catheter, aspiration pump), with labels",
     "source_key": "web:brainmed.com/info/detail?id=51164",
     "source": "brainmed.com/info/detail?id=51164, article image (uncropped source of the main picture)",
     "source_url": "https://medtion-image.medtion.com/pgc/20250409/8911cefa18e30db24504d880554b0cca",
     "where": "article image https://medtion-image.medtion.com/pgc/20250409/8911cefa18e30db24504d880554b0cca. (uncropped source of the main picture)",
     "licence": "news/company image, publisher copyright"
    },
    {
     "id": "rational_denova2023_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Patent drawing: catheter controller whose delivery turntable stores and feeds the catheter (Denova patent; tie to RATIONAL inferred)",
     "source_key": "patent:WO2023274259A1",
     "source": "patent:WO2023274259A1, Fig. 1, (applicant 杭州德诺脑神经医疗科技有限公司)",
     "source_url": "https://patentimages.storage.googleapis.com/09/dd/0e/a374aa1ff4b0a5/PCTCN2022102091-appb-300001.png",
     "where": "Fig. 1, https://patentimages.storage.googleapis.com/09/dd/0e/a374aa1ff4b0a5/PCTCN2022102091-appb-300001.png (applicant 杭州德诺脑神经医疗科技有限公司)",
     "licence": "patent drawing (public)"
    }
   ],
   "sources": [
    {
     "key": "yang2025_use",
     "doi": "10.1001/jamaneurol.2025.0418",
     "url": null,
     "title": "Use of a Robot-Assisted Thrombectomy System in Acute Ischemic Stroke",
     "year": 2025,
     "venue": "JAMA Neurology"
    },
    {
     "key": "riosgarcia2026_thrombectomy",
     "doi": "10.1007/s11701-026-03535-x",
     "url": null,
     "title": "Robot-Assisted Mechanical Thrombectomy for Neurointerventional Surgery: An Exploratory Scoping Review",
     "year": 2026,
     "venue": "Journal of Robotic Surgery"
    },
    {
     "key": "brainmed2025_rational",
     "doi": null,
     "url": "https://www.brainmed.com/info/detail?id=51164",
     "title": "JAMA Neurology: Early Clinical Results of the First Use of Robot-Assisted Mechanical Thrombectomy for Acute Ischemic Stroke",
     "year": 2025,
     "venue": null
    },
    {
     "key": "clinicaltrials2023_nct05972252",
     "doi": null,
     "url": "https://clinicaltrials.gov/study/NCT05972252",
     "title": "First-in-man Study of the Cerebrovascular Interventional Procedural Control System (A Feasibility Study to Evaluate the Safety and Efficacy of the Cerebrovascular Interventional Procedural Control System in Treatment of Acute Ischemic Stroke)",
     "year": 2023,
     "venue": null
    }
   ],
   "read_level": "partial",
   "read_level_detail": "partial (PMC page via S8); web (brainmed 2025-04-09; ClinicalTrials.gov API v2)",
   "notes": "Only human thrombectomy robot series with all four devices driven. No regulatory approval found (search for 2026 NMPA approval found nothing). Developer: 杭州德诺脑神经医疗科技有限公司 (trial sponsor name 'Hangzhou Dinova Neuroscience Technology Co., Ltd'; 'Denova Medtech' in yang2025_use), co-developed with Beijing Tiantan Hospital (Gao Feng team) over five years: brainmed 2025-04-09, https://www.brainmed.com/info/detail?id=51164 (reposted from WeChat 神经介入在线), and ClinicalTrials.gov API v2 NCT05972252 (P9_two_robots.md §1). Trial NCT05972252 'First-in-man Study of the Cerebrovascular Interventional Procedural Control System': Beijing Tiantan, contact Feng Gao MD, start 2023-10-15, status UNKNOWN (last verified 2023-10). Consumable: yang2025_use writes DNNSJ07-IR, brainmed DNNS107-IR; the paper's spelling is kept. X5 excluded the row (no picture); X6 2026-11-08 re-included it after P9 found the picture (data/images_P9.csv, grade C).",
   "maintainers_own": false,
   "found_by": "commercial"
  },
  {
   "schema_version": 1,
   "id": "telos_imperativecare2026",
   "name": "Telos",
   "full_name": "Telos",
   "group": "Imperative Care",
   "group_short": "Imperative Care",
   "family": "commercial",
   "category": "clinical-stage",
   "first_year": 2026,
   "latest_year": 2026,
   "versions": "N.R.",
   "target_anatomy": "neurovascular (stroke), remote ambition",
   "devices": [
    "not-reported"
   ],
   "devices_driven": "N.R.",
   "n_dof": null,
   "n_dof_detail": "N.R.",
   "translation_mechanism": "not-reported",
   "translation_detail": "N.R.",
   "rotation_mechanism": "not-reported",
   "rotation_detail": "N.R.",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "N.R.",
   "haptics_leader": "N.R.",
   "imaging_compat": "N.R.",
   "sterility": "N.R.",
   "highest_validation": "bench",
   "validation_detail": "preclinical per george2025_robot Table 2; no cases reported (hlth.com 2026-03-20)",
   "key_numbers": "US$100M convertible-note round March 2026",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "render",
    "source": "https://www.imperativecare.com/wp-content/uploads/2026/10/93fd07aaf2014b2b5c40990c288f188d622d2193-scaled.png (alt text \"The Telos robotic platform\"), page https://www.imperativecare.com/robotics-platform",
    "source_url": "https://www.imperativecare.com/wp-content/uploads/2026/10/93fd07aaf2014b2b5c40990c288f188d622d2193-scaled.png",
    "licence": "press image",
    "credit": "https://www.imperativecare.com/wp-content/uploads/2026/10/93fd07aaf2014b2b5c40990c288f188d622d2193-scaled.png (alt text \"The Telos robotic platform\"), page https://www.imperativecare.com/robotics-platform. Licence: press image.",
    "edits": "RGBA composited on black (the page background); cropped to the right 1260 px where the object is; no other edit; not upscaled",
    "file": null
   },
   "pictures": [],
   "sources": [
    {
     "key": "george2025_robot",
     "doi": "10.1016/j.jscai.2025.102568",
     "url": null,
     "title": "Robot-Assisted Cardiovascular Interventions",
     "year": 2025,
     "venue": "Journal of the Society for Cardiovascular Angiography & Interventions"
    }
   ],
   "read_level": "web",
   "read_level_detail": "web",
   "notes": "New 2026 funding; no clearance or submission stated.",
   "maintainers_own": false,
   "found_by": "commercial"
  },
  {
   "schema_version": 1,
   "id": "magnendo_magnendo2026",
   "name": "Magnendo",
   "full_name": "Magnendo magnetic guidewire robot",
   "group": "Magnendo (MIT spin-out; Penumbra-led Series A US$18M, July 2026)",
   "group_short": "Magnendo",
   "family": "commercial",
   "category": "magnetic-navigation",
   "first_year": 2026,
   "latest_year": 2026,
   "versions": "N.R.",
   "target_anatomy": "neurovascular access (stroke)",
   "devices": [
    "guidewire"
   ],
   "devices_driven": "magnetically steerable guidewires with robotic control",
   "n_dof": null,
   "n_dof_detail": "N.R.",
   "translation_mechanism": "magnetic",
   "translation_detail": "magnetic",
   "rotation_mechanism": "magnetic-field",
   "rotation_detail": "magnetic",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "N.R.",
   "haptics_leader": "N.R.",
   "imaging_compat": "N.R.",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "preparing first-in-human studies (santelog summary of press release)",
   "key_numbers": "US$18M Series A",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "render",
    "source": "https://cdn.prod.website-files.com/66671603a2d58c965e1693ff/6a5fd7d38e72bc4f2bf32059_Magnendo_Representative%20Image_1.png (13334x9000; home page https://www.magnendo.com/)",
    "source_url": "https://cdn.prod.website-files.com/66671603a2d58c965e1693ff/6a5fd7d38e72bc4f2bf32059_Magnendo_Representative%20Image_1.png",
    "licence": "press image (Magnendo)",
    "credit": "https://cdn.prod.website-files.com/66671603a2d58c965e1693ff/6a5fd7d38e72bc4f2bf32059_Magnendo_Representative%20Image_1.png (13334x9000; home page https://www.magnendo.com/). Licence: press image (Magnendo).",
    "edits": "cropped (1100,1000)-(13334,8400), downscaled 3.4x to 3600 px wide (LANCZOS)",
    "file": null
   },
   "pictures": [
    {
     "id": "magnendo_magnendo2026_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Magnetic guidewire threaded through a transparent neurovascular phantom",
     "source_key": "web:magnendo.com",
     "source": "magnendo.com, (magnendo.com home page)",
     "source_url": "https://cdn.prod.website-files.com/66671603a2d58c965e1693ff/666df608fd72bb5136b86c81_Photo1_small.jpg",
     "where": "https://cdn.prod.website-files.com/66671603a2d58c965e1693ff/666df608fd72bb5136b86c81_Photo1_small.jpg (magnendo.com home page)",
     "licence": "press image"
    }
   ],
   "sources": [],
   "read_level": "web",
   "read_level_detail": "web (search snippet only)",
   "notes": "Likely the commercial form of the MIT telerobotic magnetic guidewire (S8 row); academic precursor is A5 scope.",
   "maintainers_own": false,
   "found_by": "commercial"
  },
  {
   "schema_version": 1,
   "id": "raysight_raysight2025",
   "name": "Raysight PCI",
   "full_name": "Raysight Medical PCI robot",
   "group": "Raysight Medical",
   "group_short": "Raysight Medical",
   "family": "commercial",
   "category": "clinical-stage",
   "first_year": 2025,
   "latest_year": 2026,
   "versions": "N.R.",
   "target_anatomy": "coronary",
   "devices": [
    "guidewire",
    "catheter",
    "therapeutic-device"
   ],
   "devices_driven": "3 channels: guide catheter, guidewire, balloon/stent device",
   "n_dof": null,
   "n_dof_detail": "N.R.",
   "translation_mechanism": "not-reported",
   "translation_detail": "N.R.",
   "rotation_mechanism": "not-reported",
   "rotation_detail": "N.R.",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "N.R.",
   "haptics_leader": "N.R.",
   "imaging_compat": "N.R.",
   "sterility": "N.R.",
   "highest_validation": "animal",
   "validation_detail": "3 pigs, 34 episodes (liu2026_ai)",
   "key_numbers": "correct-command rate 83.6-95.6% (not task success)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "AI controller on live fluoroscopy in pig (liu2026_ai, full; sim_to_real flagged no in S7b)",
   "picture": {
    "status": "cleared",
    "grade": "B",
    "kind": "clinical-photo",
    "source": "liu2026_ai Fig. 1(b), MDPI full-resolution figure https://mdpi-res.com/bioengineering/bioengineering-13-00848/article_deploy/html/images/bioengineering-13-00848-g001.png (1796x1176; article https://www.mdpi.com/2306-5354/13/8/848)",
    "source_url": "https://doi.org/10.3390/bioengineering13080848",
    "licence": "CC BY 4.0",
    "credit": "Liu et al., Bioengineering (2026), Fig. 1(b). CC BY 4.0.",
    "edits": "cropped (78,662)-(882,1172) of the 1796x1176 MDPI image, i.e. panel (b) right of the panel letter; no erasing; not upscaled",
    "file": "pictures/raysight_raysight2025.jpg"
   },
   "pictures": [
    {
     "id": "raysight_raysight2025_01",
     "status": "cleared",
     "file": "pictures/extra/raysight_raysight2025_01.jpg",
     "thumb": "pictures/thumbs/raysight_raysight2025_01.jpg",
     "kind": "render",
     "caption": "Rendering of the Raysight robot on the patient table beside a C-arm",
     "source_key": "liu2026_ai",
     "source": "Liu et al., Bioengineering (2026), Fig. 1(a), PMC13509165",
     "source_url": "https://doi.org/10.3390/bioengineering13080848",
     "where": "Fig. 1(a), PMC13509165",
     "licence": "CC BY 4.0"
    }
   ],
   "sources": [
    {
     "key": "liu2026_ai",
     "doi": "10.3390/bioengineering13080848",
     "url": null,
     "title": "AI-Driven Robotic PCI: A Perception-to-Action Framework for Coronary Guidewire Control",
     "year": 2026,
     "venue": "Bioengineering"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (S8/S7b)",
   "notes": "Interface proprietary.",
   "maintainers_own": false,
   "found_by": "commercial"
  },
  {
   "schema_version": 1,
   "id": "cgci_magnetecs2011",
   "name": "CGCI",
   "full_name": "CGCI (Catheter Guidance Control and Imaging) remote magnetic navigation system",
   "group": "Magnetecs Corp.",
   "group_short": "Magnetecs",
   "family": "commercial",
   "category": "magnetic-navigation",
   "first_year": 2011,
   "latest_year": 2013,
   "versions": "single system: animal validation in 10 pigs (gang2011_dynamically, abstract); initial human safety and feasibility protocol at La Paz University Hospital, Madrid, 5 flutter ablations (filgueirasrama2013_remote, Table 1); later discontinued (mandhumula2025_robotic: 'now seems to have been discontinued', 'not adopted commercially')",
   "target_anatomy": "cardiac electrophysiology: right and left atrial flutter ablation (filgueirasrama2013_remote Table 1); pig left atrium mapping and RF lesions (gang2011_dynamically abstract)",
   "devices": [
    "catheter",
    "sheath"
   ],
   "devices_driven": "magnetized irrigated gold-tip EP ablation catheter (MedFact) with three permanent-magnet pellets at the tip, through an Agilis ES sheath (filgueirasrama2013_remote Protocol 1, Fig. 1); 4-mm-tip ablation catheter in pigs (gang2011_dynamically abstract); catheter 7 Fr / 2.2 mm (jeong2017_feasibility Introduction)",
   "n_dof": 3,
   "n_dof_detail": "3 (mandhumula2025_robotic Table 1; alekseeva2025_design Table 14); field shaped by 8 coil-core electromagnets, push-pull by field gradient (filgueirasrama2013_remote Representative Results) plus a motorized linear catheter advancer",
   "translation_mechanism": "magnetic",
   "translation_detail": "magnetic (field-gradient push-pull at the tip); motorized linear catheter advancement mechanism with a sterilizable wheel-drive gearbox on a motor base, joystick-controlled slack/advance (filgueirasrama2013_remote Protocol 1, Fig. 2A, 2C)",
   "rotation_mechanism": "magnetic-field",
   "rotation_detail": "tip direction by dynamically shaped field of 8 fixed electromagnets, 4 above and 4 below the patient in a semi-spherical chamber (li2020_magnetic Sec. 3.3; gang2011_dynamically abstract)",
   "device_range": "N.R.",
   "footprint_mm": "N.R. (semi-spherical chamber of 8 electromagnets around the torso, li2020_magnetic Fig. 5)",
   "mass_kg": "N.R.",
   "force_sensing": "none reported",
   "haptics_leader": "no: right-hand 3D controller and left-hand 3-axis joystick at a remote operation console (filgueirasrama2013_remote Fig. 2B-C)",
   "imaging_compat": "X-ray fluoroscopy, EnSite NavX electroanatomic mapping, EP recording and ICE unified at the operation console (filgueirasrama2013_remote Protocol 1); recording and fluoroscopic equipment unaffected by the fields (gang2011_dynamically abstract)",
   "sterility": "sterilizable wheel-drive gearbox, disposable sheath clip and leg mount on the advancer (filgueirasrama2013_remote Fig. 2A)",
   "highest_validation": "human",
   "validation_detail": "human: 5 atrial flutter ablations (3 left, 2 counterclockwise right), acute success 5/5, no procedure-derived complications, no recurrence at 3-11 months (filgueirasrama2013_remote Table 1); animal: 10 pigs, left-atrial mapping, linear and circumferential RF lesions, selective PV isolation in a subset (gang2011_dynamically abstract)",
   "key_numbers": "field up to 0.16 T (filgueirasrama2013_remote Protocol 1); 0.14 T and 0.7 T/m gradients (mandhumula2025_robotic text); pigs, automated mode: 96 +/- 8.4% reproducible, 1.9 +/- 0.4 mm from target, 11.6 +/- 3.5 s to target, lesion depth 78.5 +/- 12.1% of atrial wall (gang2011_dynamically abstract); five initial experimental procedures: 95.7% reproducible, 1.9 +/- 0.9 mm, 23.28 +/- 14.8 s (filgueirasrama2013_remote Representative Results)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "photo",
    "source": "li2020_magnetic Fig. 5 (Hwang 2020; reproduced there from Moya 2013 Rev Esp Cardiol)",
    "source_url": "https://doi.org/10.1007/s11370-020-00311-0",
    "licence": "publisher copyright",
    "credit": "Hwang et al., Intelligent Service Robotics (2020), Fig. 5. publisher copyright.",
    "edits": "native extract from p. 5; no crop; none upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "cgci_magnetecs2011_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Motorized catheter advancer, 3D controller and joystick",
     "source_key": "filgueirasrama2013_remote",
     "source": "Filgueiras-Rama et al., Journal of Visualized Experiments (2013), Fig. 2, PMC3665328",
     "source_url": "https://doi.org/10.3791/3658",
     "where": "Fig. 2, PMC3665328",
     "licence": "CC BY-NC-ND 3.0"
    },
    {
     "id": "cgci_magnetecs2011_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "CGCI chamber with the operation console inset",
     "source_key": "li2024_design",
     "source": "Li et al., IEEE Transactions on Medical Robotics and Bionics (2024), Fig. 1(G), p. 2",
     "source_url": "https://doi.org/10.1109/tmrb.2024.3377374",
     "where": "Fig. 1(G), p. 2",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "gang2011_dynamically",
     "doi": "10.1161/circep.110.959692",
     "url": null,
     "title": "Dynamically Shaped Magnetic Fields: Initial Animal Validation of a New Remote Electrophysiology Catheter Guidance and Control System",
     "year": 2011,
     "venue": "Circulation: Arrhythmia and Electrophysiology"
    },
    {
     "key": "filgueirasrama2013_remote",
     "doi": "10.3791/3658",
     "url": null,
     "title": "Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures",
     "year": 2013,
     "venue": "Journal of Visualized Experiments"
    },
    {
     "key": "li2020_magnetic",
     "doi": "10.1007/s11370-020-00311-0",
     "url": null,
     "title": "A review of magnetic actuation systems and magnetically actuated guidewire- and catheter-based microrobots for vascular interventions",
     "year": 2020,
     "venue": "Intelligent Service Robotics"
    },
    {
     "key": "mandhumula2025_robotic",
     "doi": "10.14797/mdcvj.1652",
     "url": null,
     "title": "Robotic Systems in Cardiovascular Interventions: Evolving Platforms and the Path Forward",
     "year": 2025,
     "venue": "Methodist DeBakey Cardiovascular Journal"
    },
    {
     "key": "li2024_design",
     "doi": "10.1109/tmrb.2024.3377374",
     "url": null,
     "title": "Robotic Systems Design in Endovascular Treatment",
     "year": 2024,
     "venue": "IEEE Transactions on Medical Robotics and Bionics"
    },
    {
     "key": "rafiitari2014_current",
     "doi": "10.1007/s10439-013-0946-8",
     "url": null,
     "title": "Current and Emerging Robot-Assisted Endovascular Catheterization Technologies: A Review",
     "year": 2014,
     "venue": "Annals of Biomedical Engineering"
    },
    {
     "key": "alekseeva2025_design",
     "doi": "10.1002/rob.22480",
     "url": null,
     "title": "The Design of Endovascular Robots for Cardiac Interventions: A Survey",
     "year": 2024,
     "venue": "Journal of Field Robotics"
    },
    {
     "key": "jeong2017_feasibility",
     "doi": "10.1007/s12555-015-0269-7",
     "url": null,
     "title": "Feasibility study on magnetically steerable guidewire device for percutaneous coronary intervention",
     "year": 2016,
     "venue": "International Journal of Control, Automation and Systems"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (filgueirasrama2013_remote, Europe PMC full text); abstract (gang2011_dynamically); review-only for status (li2020_magnetic, mandhumula2025_robotic)",
   "notes": "Family: commercial (A4 scope; clinical-stage magnetic navigation). A4 had set it aside as EP-only and discontinued; the author put it in (round 8). data/snowball_candidates.csv files Gang 2011 under 'Niobe': it is the CGCI paper. Regulatory clearance N.R. in the sources read. Conflict: field maximum 0.16 T (filgueirasrama2013_remote) vs 0.14 T (mandhumula2025_robotic).",
   "maintainers_own": false,
   "found_by": "commercial"
  },
  {
   "schema_version": 1,
   "id": "phocus_aeon2015",
   "name": "Aeon Phocus",
   "full_name": "Aeon Phocus electromagnetic catheter steering system",
   "group": "Aeon Scientific AG (ETH Zurich spin-off)",
   "group_short": "Aeon Scientific",
   "family": "commercial",
   "category": "magnetic-navigation",
   "first_year": 2015,
   "latest_year": 2017,
   "versions": "single system: CE mark announced 2015-07-30 (startupticker2015_aeon); host of the ETH magnetic-catheter tests of 2017 (chautems2017_tethered, chautems2017_variable); company no longer in business (li2020_magnetic Sec. 3.4); 'discontinued despite regulatory approval' (mandhumula2025_robotic)",
   "target_anatomy": "cardiac arrhythmias (catheter ablation) in all four heart chambers (chautems2017_tethered Sec. III-A)",
   "devices": [
    "catheter"
   ],
   "devices_driven": "magnetic ablation catheters (model N.R.); in ETH tests a tethered magnet (NdFeB, 29 mm long, 5 mm radius) and variable-stiffness magnetic catheters with LMPA segments (chautems2017_tethered Fig. 7; chautems2017_variable)",
   "n_dof": 3,
   "n_dof_detail": "3 (alekseeva2025_design Table 14); field and field gradient from 7 electromagnets (chautems2017_tethered Sec. II)",
   "translation_mechanism": "magnetic",
   "translation_detail": "magnetic (field gradient on the tip magnet); catheter advance mechanism N.R.",
   "rotation_mechanism": "magnetic-field",
   "rotation_detail": "tip direction by field of 7 electromagnets arranged around the patient's torso (li2020_magnetic Sec. 3.4); static electromagnets (chautems2017_tethered Sec. I) vs 'movable electromagnets' (mandhumula2025_robotic): conflict",
   "device_range": "N.R.",
   "footprint_mm": "N.R. (encloses the patient's upper body, li2020_magnetic Fig. 6b)",
   "mass_kg": "N.R.",
   "force_sensing": "none in the system; ETH added Hall sensors around the workspace for field correction (chautems2017_tethered Sec. II)",
   "haptics_leader": "no: joystick in a separate control room (li2020_magnetic Sec. 3.4; chautems2017_tethered Sec. III-A)",
   "imaging_compat": "integrated with a Siemens Artis Zee angiography system (chautems2017_tethered Fig. 6; li2020_magnetic Sec. 3.4)",
   "sterility": "N.R.",
   "highest_validation": "bench",
   "validation_detail": "bench only in the sources read: tethered-magnet trajectories and force measurements inside the Aeon Phocus at Aeon's lab (chautems2017_tethered Sec. III); variable-stiffness catheter configurations in the Aeon field (chautems2017_variable Fig. 3). Clinical use is stated ('a medically certified system currently in clinical use', chautems2017_tethered abstract) but no patient study was found; alekseeva2025_design Table 14 gives 'ex vivo phantom studies (TRL3)'",
   "key_numbers": "7 electromagnets; model vs measured force error below 0.01 N, nine points at 0.071 +/- 0.005 N (chautems2017_tethered Sec. III-C); field controlled closed-loop at 1 Hz in the ETH tests (chautems2017_tethered Sec. II); 100 mT used to load a VS catheter with 0.003 Nm (chautems2017_variable Sec. III)",
   "sim_model": "none found (linear field model with saturation correction, no simulator; chautems2017_tethered Sec. II)",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "photo",
    "source": "chautems2017_variable Fig. 1(B) (same photo as li2020_magnetic Fig. 6a)",
    "source_url": "https://doi.org/10.1109/iros.2017.8202155",
    "licence": "publisher copyright",
    "credit": "Chautems et al., 2017 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (2017), Fig. 1. publisher copyright.",
    "edits": "native extract from chautems2017_variable-stiffness_IROS.pdf p. 1; cropped to panel B; none upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "phocus_aeon2015_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "Aeon Phocus electromagnets beside the patient table and Artis Zee",
     "source_key": "chautems2017_tethered",
     "source": "Chautems et al., 2017 IEEE International Conference on Robotics and Automation (ICRA) (2017), Fig. 6, p. 5",
     "source_url": "https://doi.org/10.1109/icra.2017.7989562",
     "where": "Fig. 6, p. 5",
     "licence": "publisher copyright"
    },
    {
     "id": "phocus_aeon2015_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "Aeon Phocus in the angiography suite with the control room inset",
     "source_key": "li2024_design",
     "source": "Li et al., IEEE Transactions on Medical Robotics and Bionics (2024), Fig. 1(H), p. 2",
     "source_url": "https://doi.org/10.1109/tmrb.2024.3377374",
     "where": "Fig. 1(H), p. 2",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "chautems2017_tethered",
     "doi": "10.1109/icra.2017.7989562",
     "url": null,
     "title": "The tethered magnet: Force and 5-DOF pose control for cardiac ablation",
     "year": 2017,
     "venue": "2017 IEEE International Conference on Robotics and Automation (ICRA)"
    },
    {
     "key": "chautems2017_variable",
     "doi": "10.1109/iros.2017.8202155",
     "url": null,
     "title": "A variable stiffness catheter controlled with an external magnetic field",
     "year": 2017,
     "venue": "2017 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS)"
    },
    {
     "key": "startupticker2015_aeon",
     "doi": null,
     "url": null,
     "title": "Green light to Aeon Scientific to launch its Aeon Phocus",
     "year": 2015,
     "venue": null
    },
    {
     "key": "li2020_magnetic",
     "doi": "10.1007/s11370-020-00311-0",
     "url": null,
     "title": "A review of magnetic actuation systems and magnetically actuated guidewire- and catheter-based microrobots for vascular interventions",
     "year": 2020,
     "venue": "Intelligent Service Robotics"
    },
    {
     "key": "li2024_design",
     "doi": "10.1109/tmrb.2024.3377374",
     "url": null,
     "title": "Robotic Systems Design in Endovascular Treatment",
     "year": 2024,
     "venue": "IEEE Transactions on Medical Robotics and Bionics"
    },
    {
     "key": "mandhumula2025_robotic",
     "doi": "10.14797/mdcvj.1652",
     "url": null,
     "title": "Robotic Systems in Cardiovascular Interventions: Evolving Platforms and the Path Forward",
     "year": 2025,
     "venue": "Methodist DeBakey Cardiovascular Journal"
    },
    {
     "key": "alekseeva2025_design",
     "doi": "10.1002/rob.22480",
     "url": null,
     "title": "The Design of Endovascular Robots for Cardiac Interventions: A Survey",
     "year": 2024,
     "venue": "Journal of Field Robotics"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (chautems2017_tethered, chautems2017_variable); web (startupticker2015_aeon)",
   "notes": "Family: commercial (A4 scope; CE-marked magnetic navigation). A4 had set it aside as EP-only; the author put it in (round 8). Nanoflex (navion_nanoflex2025) is a later, different ETH spin-off. Same ETH group tested the tethered magnet in it (review_coverage rows 'ETH_CHAUTEMS', not added here).",
   "maintainers_own": false,
   "found_by": "commercial"
  },
  {
   "schema_version": 1,
   "id": "capstan_capstanmedical2025",
   "name": "Capstan TMVR",
   "full_name": "Capstan Medical robotic TMVR system (catheter-based robotic delivery platform)",
   "group": "Capstan Medical",
   "group_short": "Capstan Medical",
   "family": "commercial",
   "category": "clinical-stage",
   "first_year": 2025,
   "latest_year": 2026,
   "versions": "single: first-in-human cases in Santiago, early 2025 (capstan2025_press); registered first-in-human study NCT06600191 (nct06600191_capstan)",
   "target_anatomy": "transcatheter mitral valve replacement for moderate-severe or worse mitral regurgitation (nct06600191_capstan); transfemoral venous access ('up through your femoral vein', santacruzworks_capstan)",
   "devices": [
    "catheter"
   ],
   "devices_driven": "own steerable delivery catheter and TMVR implant (capstan2025_press; mandhumula2025_robotic text)",
   "n_dof": 3,
   "n_dof_detail": "3-4 (mandhumula2025_robotic Table 1); robot 'controlling all six knobs at the same time' (santacruzworks_capstan, D. Wallace)",
   "translation_mechanism": "friction-roller",
   "translation_detail": "friction-roller (mandhumula2025_robotic Table 1 'Friction rollers'; Fig. 2I 'Drive-mechanism consisting roller assembly')",
   "rotation_mechanism": "tendon-bending",
   "rotation_detail": "steerable-catheter deflection by a multi-spool tendon mechanism that also deploys the implant (mandhumula2025_robotic text, Table 1 'Pull-wires'); shaft rotation N.R.",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "N.R.",
   "haptics_leader": "N.R.",
   "imaging_compat": "'Visual (Likely TEE and X-ray)' (mandhumula2025_robotic Table 1)",
   "sterility": "N.R. (robot draped in an animal-lab photo, santacruzworks_capstan)",
   "highest_validation": "human",
   "validation_detail": "human: 2 TMVR patients at Hospital Clinico Universidad Catolica, Santiago, both with mitral regurgitation eliminated and unobstructed LVOT (capstan2025_press, 2025-03-06); registered FIH study NCT06600191: 10 participants (estimated), 4 sites (Melbourne, Sao Paulo, Santiago, Auckland), recruiting (nct06600191_capstan, accessed 2026-11-08)",
   "key_numbers": "NCT06600191 first posted 2024-09-19, start 2025-02-24, primary completion 2026-12 (estimated), last update 2026-08-28 (nct06600191_capstan); USD 110 M financing (PR Newswire 2024-12-11)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "drawing",
    "source": "mandhumula2025_robotic Fig. 2(I) (PMC12513367 figure file https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ae99/12513367/445add2a14f2/mdcvj-21-5-1652-g2.jpg)",
    "source_url": "https://doi.org/10.14797/mdcvj.1652",
    "licence": "CC BY-NC 4.0",
    "credit": "Mandhumula et al., Methodist DeBakey Cardiovascular Journal (2025), Fig. 2. CC BY-NC 4.0.",
    "edits": "cropped panel (I) from the 800 px PMC figure; no edit; none upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "capstan_capstanmedical2025_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Draped robot and delivery catheter during an animal procedure",
     "source_key": "santacruzworks_capstan",
     "source": "Works (), web photo 'Aaron Evelyn Dan lab.jpg'",
     "source_url": null,
     "where": "web photo 'Aaron Evelyn Dan lab.jpg'",
     "licence": "press image"
    }
   ],
   "sources": [
    {
     "key": "nct06600191_capstan",
     "doi": null,
     "url": null,
     "title": "Capstan Medical TMVR Study: First-in-Human Evaluation of the Capstan TMVR System (NCT06600191)",
     "year": 2024,
     "venue": null
    },
    {
     "key": "capstan2025_press",
     "doi": null,
     "url": null,
     "title": "Capstan Medical Achieves Milestone: World's First Robotic Catheter Mitral Valve Replacements Successfully Completed",
     "year": 2025,
     "venue": null
    },
    {
     "key": "santacruzworks_capstan",
     "doi": null,
     "url": null,
     "title": "Interview: Dan Wallace, Co-founder & CTO of Capstan Medical",
     "year": null,
     "venue": null
    },
    {
     "key": "mandhumula2025_robotic",
     "doi": "10.14797/mdcvj.1652",
     "url": null,
     "title": "Robotic Systems in Cardiovascular Interventions: Evolving Platforms and the Path Forward",
     "year": 2025,
     "venue": "Methodist DeBakey Cardiovascular Journal"
    }
   ],
   "read_level": "web",
   "read_level_detail": "web (press release, registry, company interview); review-only (mandhumula2025_robotic)",
   "notes": "Family: commercial (A4 scope; clinical-stage). No peer-reviewed paper; patents (Wallace 2024, mandhumula2025_robotic refs 62-64) not opened. Structural-heart (TMVR) robot, in scope like the TEER robots. Company site and press releases carry no photo of the robot; the only photo found shows it draped in an animal lab (gallery).",
   "maintainers_own": false,
   "found_by": "commercial"
  },
  {
   "schema_version": 1,
   "id": "fluxone_fluxrobotics2023",
   "name": "Flux One",
   "full_name": "Flux One mobile magnetic navigation system",
   "group": "Flux Robotics B.V. (University of Twente spin-off; Heunis, Misra)",
   "group_short": "Flux Robotics",
   "family": "commercial",
   "category": "magnetic-navigation",
   "first_year": 2023,
   "latest_year": 2026,
   "versions": "Flux One: KUKA LBR iiwa with a liquid-cooled electromagnetic coil on a mobile trolley (heunis2023_flux Sec. II-B, Fig. 4); later system on a Doosan arm in the company photo (twente_fluxrobotics, article names 'Flux 2, the latest version'); described as a prototype of ARMM (utwente2023_flux; see armm_heunis2020)",
   "target_anatomy": "fenestrated EVAR: coeliac artery and branches, SMA, left renal and contralateral common iliac arteries of an abdominal phantom (heunis2023_flux Sec. III-B)",
   "devices": [
    "guidewire"
   ],
   "devices_driven": "magnetic J-tip guidewire: Terumo Radifocus 0.032-in (0.81 mm) with a 10 mm tip of five NdFeB magnets, 2 mm diameter, silicone coated (heunis2023_flux Sec. III-A)",
   "n_dof": 7,
   "n_dof_detail": "7 (arm and coil) + surgeon push-pull 1, guidewire bent in two planes (heunis2023_flux Sec. IV-C)",
   "translation_mechanism": "magnetic",
   "translation_detail": "magnetic (tip steering); insertion by the surgeon's hand at the bedside (heunis2023_flux Sec. I, IV-C)",
   "rotation_mechanism": "magnetic-field",
   "rotation_detail": "coil pose (7-DoF arm) and coil current set field strength and direction (heunis2023_flux Sec. I-II)",
   "device_range": "tip deflection -135 to 135 deg planned (heunis2023_flux Sec. II-A)",
   "footprint_mm": "arm horizontal reach 830 (heunis2023_flux Sec. II-B)",
   "mass_kg": "120 (whole mobile trolley, heunis2023_flux Sec. II-B)",
   "force_sensing": "none on the guidewire; arm keeps a 4 N virtual interaction-force constraint (heunis2023_flux Sec. III-A)",
   "haptics_leader": "Omega.6 haptic device for coil positioning with force feedback at a virtual safety barrier, plus SpaceMouse, push buttons and touchscreen (heunis2023_flux Sec. II-B, Fig. 4e)",
   "imaging_compat": "pre-operative cone-beam CT planning and live fluoroscopy in a hybrid OR (Siemens Artis Pheno); no CT artefacts per Siemens technician (heunis2023_flux Sec. III-B)",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "silicone abdominal phantom from patient CT, 4 targets: one vascular surgeon with conventional (case 1) and magnetic (case 2) guidewire, 11 novice operators with Flux One; all targets reached, no adverse events (heunis2023_flux Sec. III-B, IV-A, IV-C). Company reports preclinical animal trials and first tests in Miami (twente_fluxrobotics), no published result",
   "key_numbers": "coil field up to 60 mT (heunis2023_flux Sec. I, citing its ref. 18); guidewire navigation time -47%; target 4: 22.7 s vs 73 s (-69%); 11-37 s per target in case 2; mean SUS 80%; coil cooling 9.2 L/min keeps surface at 45 C; arm speed limit 0.02 m/s (heunis2023_flux Sec. III-IV)",
   "sim_model": "virtual clone of the system for trajectory planning (Policy Improvement with Path Integrals), no guidewire physics simulator (heunis2023_flux Sec. II-C)",
   "has_sim_model": true,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "product-photo",
    "source": "https://cdn.twente.com/filer_public/49/a6/49a6c924-a590-47aa-bc1a-fe419149be09/fluxrobotics_home.jpeg (page https://twente.com/en/artikelen/5595/flux-robotics-verandert-operaties-met-hightech-medische-innovatie/)",
    "source_url": "https://cdn.twente.com/filer_public/49/a6/49a6c924-a590-47aa-bc1a-fe419149be09/fluxrobotics_home.jpeg",
    "licence": "press image",
    "credit": "https://cdn.twente.com/filer_public/49/a6/49a6c924-a590-47aa-bc1a-fe419149be09/fluxrobotics_home.jpeg (page https://twente.com/en/artikelen/5595/flux-robotics-verandert-operaties-met-hightech-medische-innovatie/). Licence: press image.",
    "edits": "2048 px original; cropped to the trolley, arm and coil (people at left removed); no edit; none upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "fluxone_fluxrobotics2023_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Electromagnetic coil on the KUKA arm over the aortic phantom",
     "source_key": "heunis2023_flux",
     "source": "Heunis et al., IEEE Robotics and Automation Letters (2023), Fig. 1, p. 1",
     "source_url": "https://doi.org/10.1109/lra.2023.3289108",
     "where": "Fig. 1, p. 1",
     "licence": "publisher copyright"
    },
    {
     "id": "fluxone_fluxrobotics2023_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Flux One trolley and arm in a hybrid operating room",
     "source_key": "heunis2023_flux",
     "source": "Heunis et al., IEEE Robotics and Automation Letters (2023), Fig. 4 (centre), p. 6",
     "source_url": "https://doi.org/10.1109/lra.2023.3289108",
     "where": "Fig. 4 (centre), p. 6",
     "licence": "publisher copyright"
    },
    {
     "id": "fluxone_fluxrobotics2023_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Liquid-cooled electromagnetic end-effector of Flux One",
     "source_key": "heunis2023_flux",
     "source": "Heunis et al., IEEE Robotics and Automation Letters (2023), Fig. 4(a), p. 6",
     "source_url": "https://doi.org/10.1109/lra.2023.3289108",
     "where": "Fig. 4(a), p. 6",
     "licence": "publisher copyright"
    },
    {
     "id": "fluxone_fluxrobotics2023_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Researchers with the arm-mounted coil over a vascular phantom",
     "source_key": "utwente2023_flux",
     "source": "Twente (2023), web photo (Frans Nikkels)",
     "source_url": null,
     "where": "web photo (Frans Nikkels)",
     "licence": "press image"
    }
   ],
   "sources": [
    {
     "key": "heunis2023_flux",
     "doi": "10.1109/lra.2023.3289108",
     "url": null,
     "title": "The Flux One Magnetic Navigation System: A Preliminary Assessment for Stent Implantation",
     "year": 2023,
     "venue": "IEEE Robotics and Automation Letters"
    },
    {
     "key": "twente_fluxrobotics",
     "doi": null,
     "url": null,
     "title": "Flux Robotics verandert operaties met hightech medische innovatie",
     "year": null,
     "venue": null
    },
    {
     "key": "utwente2023_flux",
     "doi": null,
     "url": null,
     "title": "Robots improve safety, efficiency and precision of vascular surgery",
     "year": 2023,
     "venue": null
    },
    {
     "key": "pescio2025_endovascular",
     "doi": "10.1080/13645706.2025.2454237",
     "url": null,
     "title": "Endovascular robotics: technical advances and future directions",
     "year": 2025,
     "venue": "Minimally Invasive Therapy & Allied Technologies"
    },
    {
     "key": "mandhumula2025_robotic",
     "doi": "10.14797/mdcvj.1652",
     "url": null,
     "title": "Robotic Systems in Cardiovascular Interventions: Evolving Platforms and the Path Forward",
     "year": 2025,
     "venue": "Methodist DeBakey Cardiovascular Journal"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (heunis2023_flux); web (twente_fluxrobotics, utwente2023_flux)",
   "notes": "Family: commercial (A4 scope) by the author's decision (round 8; pescio2025 lists it as commercial-stage). By the Sec. II-A family rule it is preclinical: no clearance, no registered study, no patient found. Same group as armm_heunis2020 (kept as a separate row). The main picture shows the later Doosan-arm system, not the KUKA of the 2023 paper; the paper's photos are in the gallery.",
   "maintainers_own": false,
   "found_by": "commercial"
  },
  {
   "schema_version": 1,
   "id": "coast_jeong2020",
   "name": "COAST",
   "full_name": "COAST guidewire robot (coaxially aligned steerable)",
   "group": "Desai, Georgia Tech Robomed Lab",
   "group_short": "Georgia Tech",
   "family": "tip",
   "category": "actuated-device",
   "first_year": 2020,
   "latest_year": 2025,
   "versions": "2020 3-tube design 0.40 mm OD (jeong2020_design); 2022 same family run under fluoroscopic path planning, ex vivo porcine aorta (ravigopal2022_fluoroscopic); 2023 larger 0.89 mm OD with 3-fibre FBG shape+force sensing (deaton2023_simultaneous); 2025 two-tube 'modified COAST', 0.35 mm outer tube, 0.66 mm Pebax sheath, joystick teleoperation (brumfiel2025_modified)",
   "target_anatomy": "cardiovascular / peripheral (aortic bifurcation phantom, paediatric carotid and arch phantoms)",
   "devices": [
    "guidewire"
   ],
   "devices_driven": "the COAST wire itself (own nitinol-tube wire, not a commercial guidewire)",
   "n_dof": 4,
   "n_dof_detail": "4 actuated axes in 2020 prototype (tendon stroke X1, inner-tube position X2, outer-tube advance X3, whole-module advance X4); roll added by spur gear in 2025 version",
   "translation_mechanism": "tendon/tip-actuation",
   "translation_detail": "tendon/tip-actuation",
   "rotation_mechanism": "rotating-drive-unit",
   "rotation_detail": "none in 2020 prototype; spur-gear roll of actuation module (2025)",
   "device_range": "2020 prototype 188-257 mm tubes, 'shorter than a clinical wire'; handheld spooling variant takes up to 1.5 m (chavenet2026_handheld)",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "2020: miniature force sensor on tendon tension; 2023: FBG triplet tip force, RMSE 0.005-0.027 N (bench)",
   "haptics_leader": "no (Xbox controller teleoperation 2025)",
   "imaging_compat": "fluoroscopy used 2022, 2025; MR compatibility N.R.",
   "sterility": "N.R.",
   "highest_validation": "ex-vivo",
   "validation_detail": "ex vivo porcine aorta, navigation with COAST under fluoroscopic reconstruction (ravigopal2022 abstract); 2025: one qualitative teleoperated traversal of an aortic-bifurcation phantom with pulsatile flow, no success counts; 2020: phantom, no success count",
   "key_numbers": "2020: tendon-stroke model RMSE 0.032 mm (27-37 mm bending lengths); follow-the-leader tip-to-path mean 4.53 mm (low curvature) and 14.66 mm (high curvature) in free space; 2023 shape RMSE 0.62-1.94 mm by motion type; 2025 wire buckled between introducer and actuator so insertion was hand-assisted",
   "sim_model": "analytical tendon-stroke / static model with experimental fit (jeong2020 Sec. III, full); shape-from-FBG reconstruction (deaton2023, full); no physics simulator found",
   "has_sim_model": true,
   "sim2real": "none-found",
   "sim2real_detail": "none found (all control open-loop or teleoperated; no learned policy)",
   "picture": {
    "status": "not-cleared",
    "grade": "A",
    "kind": "photo",
    "source": "deaton2023_simultaneous Fig. 1 (lower photo: COAST actuation stage with guidewire)",
    "source_url": "https://doi.org/10.1109/lra.2023.3267008",
    "licence": "publisher copyright (IEEE)",
    "credit": "Deaton et al., IEEE Robotics and Automation Letters (2023), Fig. 1. publisher copyright (IEEE).",
    "edits": "native extract (2014 px); cropped; 2 black arrowheads on the white background erased (LaMa, 3 passes, looked at 4x zoom)",
    "file": null
   },
   "pictures": [
    {
     "id": "coast_jeong2020_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "Side view of the four-carriage linear actuation stage on acrylic base",
     "source_key": "jeong2020_design",
     "source": "Jeong et al., IEEE Robotics and Automation Letters (2020), Fig. 3(c), p. 3",
     "source_url": "https://doi.org/10.1109/lra.2020.3004782",
     "where": "Fig. 3(c), p. 3",
     "licence": "publisher copyright"
    },
    {
     "id": "coast_jeong2020_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Modified COAST actuation unit on a robot arm beside the C-arm",
     "source_key": "brumfiel2025_modified",
     "source": "Brumfiel et al. (2025), Fig. 2(a-1), p. 2",
     "source_url": "https://arxiv.org/abs/2512.13477",
     "where": "Fig. 2(a-1), p. 2",
     "licence": "arXiv non-exclusive distribution licence 1.0"
    },
    {
     "id": "coast_jeong2020_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "COAST guidewire actuation system with ex vivo porcine aorta under C-arm",
     "source_key": "ravigopal2022_fluoroscopic",
     "source": "Ravigopal et al., IEEE Robotics and Automation Letters (2022), Fig. 9(a), p. 7",
     "source_url": "https://doi.org/10.1109/lra.2022.3207568",
     "where": "Fig. 9(a), p. 7",
     "licence": "publisher copyright"
    },
    {
     "id": "coast_jeong2020_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Rendering of the enclosed two-tube modified COAST actuation unit",
     "source_key": "brumfiel2025_modified",
     "source": "Brumfiel et al. (2025), Fig. 1, p. 1",
     "source_url": "https://arxiv.org/abs/2512.13477",
     "where": "Fig. 1, p. 1",
     "licence": "arXiv non-exclusive distribution licence 1.0"
    },
    {
     "id": "coast_jeong2020_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Rendering of the modified actuation unit with its cover removed",
     "source_key": "brumfiel2025_modified",
     "source": "Brumfiel et al. (2025), Fig. 1, p. 1",
     "source_url": "https://arxiv.org/abs/2512.13477",
     "where": "Fig. 1, p. 1",
     "licence": "arXiv non-exclusive distribution licence 1.0"
    },
    {
     "id": "coast_jeong2020_06",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "COAST guidewire choosing branches in a bifurcation phantom, image sequence",
     "source_key": "jeong2020_design",
     "source": "Jeong et al., IEEE Robotics and Automation Letters (2020), Fig. 9, p. 7",
     "source_url": "https://doi.org/10.1109/lra.2020.3004782",
     "where": "Fig. 9, p. 7",
     "licence": "publisher copyright"
    },
    {
     "id": "coast_jeong2020_07",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Notched nitinol tubes of the COAST guidewire under magnification",
     "source_key": "jeong2020_design",
     "source": "Jeong et al., IEEE Robotics and Automation Letters (2020), Fig. 3(a), p. 3",
     "source_url": "https://doi.org/10.1109/lra.2020.3004782",
     "where": "Fig. 3(a), p. 3",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "jeong2020_design",
     "doi": "10.1109/lra.2020.3004782",
     "url": null,
     "title": "Design, Modeling, and Control of a Coaxially Aligned Steerable (COAST) Guidewire Robot",
     "year": 2020,
     "venue": "IEEE Robotics and Automation Letters"
    },
    {
     "key": "deaton2023_simultaneous",
     "doi": "10.1109/lra.2023.3267008",
     "url": null,
     "title": "Simultaneous Shape and Tip Force Sensing for the COAST Guidewire Robot",
     "year": 2023,
     "venue": "IEEE Robotics and Automation Letters"
    },
    {
     "key": "ravigopal2022_fluoroscopic",
     "doi": "10.1109/lra.2022.3207568",
     "url": null,
     "title": "Fluoroscopic Image-Based 3-D Environment Reconstruction and Automated Path Planning for a Robotically Steerable Guidewire",
     "year": 2022,
     "venue": "IEEE Robotics and Automation Letters"
    },
    {
     "key": "brumfiel2025_modified",
     "doi": null,
     "url": "https://arxiv.org/abs/2512.13477",
     "title": "Evaluating the Navigation Capabilities of a Modified COAST Guidewire Robot in an Anatomical Phantom Model",
     "year": 2025,
     "venue": null
    },
    {
     "key": "chavenet2026_handheld",
     "doi": null,
     "url": "https://arxiv.org/abs/2607.24629",
     "title": "Development of a Handheld Actuation Mechanism for a Tendon-driven Robotically Steered Guidewire",
     "year": 2026,
     "venue": null
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (jeong2020, deaton2023, brumfiel2025 arXiv, chavenet2026 arXiv); abstract (ravigopal2022)",
   "notes": "Family has the most hardware-complete published tendon guidewire in my scope; the 2023 paper and the 2025 modified version change OD, so quote the version with every size.",
   "maintainers_own": false,
   "found_by": "actuated-tip"
  },
  {
   "schema_version": 1,
   "id": "balloongw_barre2025",
   "name": "Balloon guidewire",
   "full_name": "Tendon-driven steerable guidewire with retractable distal balloon (+ handheld actuation)",
   "group": "Desai, Georgia Tech Robomed Lab",
   "group_short": "Georgia Tech",
   "family": "tip",
   "category": "actuated-device",
   "first_year": 2025,
   "latest_year": 2026,
   "versions": "2025 balloon guidewire (barre2025_towards); 2026 handheld actuation mechanism for tendon-driven guidewire, 0.836 kg, up to 1.5 m of wire, joystick feed/roll/bend (chavenet2026_handheld)",
   "target_anatomy": "endovascular, phantom vessel 3 mm ID with three branches",
   "devices": [
    "guidewire",
    "therapeutic-device"
   ],
   "devices_driven": "own notched-nitinol tendon guidewire (0.48 mm OD nitinol tube, 20 mm UAN bending segment, 76 um nitinol tendon in 2026 paper); balloon wire uses 0.15 mm nitinol tendon",
   "n_dof": null,
   "n_dof_detail": "bend, feed, roll (handheld); plus balloon inflation (2025)",
   "translation_mechanism": "tendon/tip-actuation",
   "translation_detail": "tendon/tip-actuation",
   "rotation_mechanism": "rotating-drive-unit",
   "rotation_detail": "motorised spool roll (handheld, 2026)",
   "device_range": "up to 1.5 m of wire spooled (2026)",
   "footprint_mm": "handheld housing 341.7 x 110.4 (Fig. 1e)",
   "mass_kg": "0.836 (handheld device)",
   "force_sensing": "N.R.",
   "haptics_leader": "no (joystick, momentary switch)",
   "imaging_compat": "C-arm in phantom test; MR compatibility N.R.",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "2025: phantom vessel under pulsatile flow, traversal, balloon inflation, flow arrest (one demonstration); 2026: one navigation of an abdominal aorta phantom, wire buckled between phantom entry and device (abstract-level counts N.R.)",
   "key_numbers": "balloon radii inflated 0.75-2.50 mm in 0.25 mm steps; 1.22 mm OD balloon on guidewire; Abaqus model of balloon inflation; pressure-channel test: position change 0.038 mm and curvature change 0.2 % (barre2025 Sec. V, context only partly read)",
   "sim_model": "Abaqus FE model of balloon inflation plus analytical curvature model (barre2025 Sec. III-IV, partial read)",
   "has_sim_model": true,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "photo",
    "source": "barre2025_towards Fig. 3(a) (actuation system, top view)",
    "source_url": "https://doi.org/10.1109/lra.2025.3590303",
    "licence": "publisher copyright (IEEE)",
    "credit": "Barré et al., IEEE Robotics and Automation Letters (2025), Fig. 3(a). publisher copyright (IEEE).",
    "edits": "native extract (2036 px); cropped at x=1345 to keep the orange zoom-box leader (which crosses the load cell) out; orange box edges beside the gauge erased (LaMa, 2 passes)",
    "file": null
   },
   "pictures": [
    {
     "id": "balloongw_barre2025_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Actuation system driving the balloon guidewire into a pulsatile-flow phantom",
     "source_key": "barre2025_towards",
     "source": "Barré et al., IEEE Robotics and Automation Letters (2025), Fig. 10(a-c), p. 5",
     "source_url": "https://doi.org/10.1109/lra.2025.3590303",
     "where": "Fig. 10(a-c), p. 5",
     "licence": "publisher copyright"
    },
    {
     "id": "balloongw_barre2025_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Handheld actuation mechanism steering the guidewire in a vascular phantom",
     "source_key": "chavenet2026_handheld",
     "source": "Chavenet et al. (2026), Fig. 2(a), p. 2",
     "source_url": "https://arxiv.org/abs/2607.24629",
     "where": "Fig. 2(a), p. 2",
     "licence": "arXiv non-exclusive distribution licence 1.0"
    },
    {
     "id": "balloongw_barre2025_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "Handheld actuation mechanism prototype with thumb joystick, cover partly open",
     "source_key": "chavenet2026_handheld",
     "source": "Chavenet et al. (2026), Fig. 1(a), p. 1",
     "source_url": "https://arxiv.org/abs/2607.24629",
     "where": "Fig. 1(a), p. 1",
     "licence": "arXiv non-exclusive distribution licence 1.0"
    },
    {
     "id": "balloongw_barre2025_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Section rendering of the handheld mechanism: spool, roll gear, tendon motor",
     "source_key": "chavenet2026_handheld",
     "source": "Chavenet et al. (2026), Fig. 1(b), p. 1",
     "source_url": "https://arxiv.org/abs/2607.24629",
     "where": "Fig. 1(b), p. 1",
     "licence": "arXiv non-exclusive distribution licence 1.0"
    },
    {
     "id": "balloongw_barre2025_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Syringe pump module that inflates the distal balloon",
     "source_key": "barre2025_towards",
     "source": "Barré et al., IEEE Robotics and Automation Letters (2025), Fig. 3(b), p. 2",
     "source_url": "https://doi.org/10.1109/lra.2025.3590303",
     "where": "Fig. 3(b), p. 2",
     "licence": "publisher copyright"
    },
    {
     "id": "balloongw_barre2025_06",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Section and exploded views of the guidewire with retractable balloon",
     "source_key": "barre2025_towards",
     "source": "Barré et al., IEEE Robotics and Automation Letters (2025), Fig. 2, p. 2",
     "source_url": "https://doi.org/10.1109/lra.2025.3590303",
     "where": "Fig. 2, p. 2",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "barre2025_towards",
     "doi": "10.1109/lra.2025.3590303",
     "url": null,
     "title": "Towards a Tendon-Driven Robotically Steerable Guidewire With a Retractable Distal Balloon",
     "year": 2025,
     "venue": "IEEE Robotics and Automation Letters"
    },
    {
     "key": "chavenet2026_handheld",
     "doi": null,
     "url": "https://arxiv.org/abs/2607.24629",
     "title": "Development of a Handheld Actuation Mechanism for a Tendon-driven Robotically Steered Guidewire",
     "year": 2026,
     "venue": null
    }
   ],
   "read_level": "full",
   "read_level_detail": "full text downloaded, read selectively (key numbers by grep); arXiv chavenet2026 read intro+methods",
   "notes": "Entry kept separate from COAST because the tube is a single notched outer tube, not three coaxial tubes.",
   "maintainers_own": false,
   "found_by": "actuated-tip"
  },
  {
   "schema_version": 1,
   "id": "srmc_abah2024",
   "name": "Robotic microcatheter",
   "full_name": "Self-steering robotic microcatheter (series-elastic, two bending segments)",
   "group": "Simaan, Vanderbilt (ARMA lab) with Chitale, VUMC",
   "group_short": "Vanderbilt",
   "family": "tip",
   "category": "actuated-device",
   "first_year": 2024,
   "latest_year": 2024,
   "versions": "single (2024 T-MRB); path planner in companion paper (ref [45] in abah2024, not read)",
   "target_anatomy": "neuroendovascular (ICA path, 2D vasculature models)",
   "devices": [
    "catheter"
   ],
   "devices_driven": "own notched-nitinol catheter: outer tube OD 1.2 mm / ID 0.95 mm, intermediate 0.89/0.725, inner 0.66 OD with 0.475 mm bore (S8 check of abah2024 Sec. IV-A); roughly 3.6 Fr at maximum OD (1.2 mm / 0.333, my conversion)",
   "n_dof": 4,
   "n_dof_detail": "4 (insertion, roll, proximal bend, distal bend; bending in two separate planes)",
   "translation_mechanism": "tendon/tip-actuation",
   "translation_detail": "tendon/tip-actuation",
   "rotation_mechanism": "rotating-drive-unit",
   "rotation_detail": "custom actuation unit roll DoF",
   "device_range": "N.R.",
   "footprint_mm": "N.R. (benchtop actuation unit on aluminium extrusion frame, Fig. 3)",
   "mass_kg": "N.R.",
   "force_sensing": "joint-level load sensing via series-elastic actuation; active compliance triggers at 0.01 N tip force (about 1 g)",
   "haptics_leader": "no",
   "imaging_compat": "bi-plane fluoroscopy for tracking (Fig. 11); catheter tracking and pose filtering algorithms",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "2D vasculature model: branch selection left and right, insertion into unknown channel under active compliance, one autonomous deployment along 2D ICA path; no success counts",
   "key_numbers": "distal segment OD about 0.88-1.2 mm (text differs, see S8 note); compliance trigger 0.01 N; autonomous insertion errors larger than simulated because passive extension floats between actuation unit and phantom entry",
   "sim_model": "kinematic model with calibration and simulated path following along 2D ICA (Fig. 8) (abah2024 Sec. V, full)",
   "has_sim_model": true,
   "sim2real": "model-based",
   "sim2real_detail": "model-based: planner configurations computed in simulation were run on the hardware; hardware position errors exceeded simulated errors (abah2024 Sec. V-C, full); no learned policy",
   "picture": {
    "status": "not-cleared",
    "grade": "A",
    "kind": "photo",
    "source": "abah2024_self Fig. 1 (photo of the 4-DOF actuation unit)",
    "source_url": "https://doi.org/10.1109/tmrb.2024.3464123",
    "licence": "CC BY-NC-ND 4.0 (PMC12245187 author manuscript; edits mean internal use only)",
    "credit": "Abah et al., IEEE Transactions on Medical Robotics and Bionics (2024), Fig. 1. CC BY-NC-ND 4.0 (PMC12245187 author manuscript; edits mean internal use only).",
    "edits": "native extract (4110 px figure); cropped to the photo; one brown arrow on the wooden base and a 6 px arrow tip erased (LaMa)",
    "file": null
   },
   "pictures": [
    {
     "id": "srmc_abah2024_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Actuation unit photo with CAD of the push-pull tube carriages",
     "source_key": "abah2024_self",
     "source": "Abah et al., IEEE Transactions on Medical Robotics and Bionics (2024), Fig. 1, p. 3",
     "source_url": "https://doi.org/10.1109/tmrb.2024.3464123",
     "where": "Fig. 1, p. 3",
     "licence": "CC BY-NC-ND 4.0 (PMC author manuscript)"
    },
    {
     "id": "srmc_abah2024_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Active compliance demonstration: microcatheter in a curved channel and beside a Phenom 21",
     "source_key": "abah2024_self",
     "source": "Abah et al., IEEE Transactions on Medical Robotics and Bionics (2024), Fig. 7, p. 6",
     "source_url": "https://doi.org/10.1109/tmrb.2024.3464123",
     "where": "Fig. 7, p. 6",
     "licence": "CC BY-NC-ND 4.0 (PMC author manuscript)"
    },
    {
     "id": "srmc_abah2024_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Video snapshots of autonomous insertion and steering in a 2D ICA model",
     "source_key": "abah2024_self",
     "source": "Abah et al., IEEE Transactions on Medical Robotics and Bionics (2024), Fig. 10, p. 7",
     "source_url": "https://doi.org/10.1109/tmrb.2024.3464123",
     "where": "Fig. 10, p. 7",
     "licence": "CC BY-NC-ND 4.0 (PMC author manuscript)"
    },
    {
     "id": "srmc_abah2024_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Microcatheter selecting the left and right branch of a Y phantom",
     "source_key": "abah2024_self",
     "source": "Abah et al., IEEE Transactions on Medical Robotics and Bionics (2024), Fig. 6, p. 6",
     "source_url": "https://doi.org/10.1109/tmrb.2024.3464123",
     "where": "Fig. 6, p. 6",
     "licence": "CC BY-NC-ND 4.0 (PMC author manuscript)"
    }
   ],
   "sources": [
    {
     "key": "abah2024_self",
     "doi": "10.1109/tmrb.2024.3464123",
     "url": null,
     "title": "Self-Steering Catheters for Neuroendovascular Interventions",
     "year": 2024,
     "venue": "IEEE Transactions on Medical Robotics and Bionics"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full",
   "notes": "Sized for microcatheter range, the smallest actuated-tip multi-DOF catheter among the read rows. Uses the CC BY-NC-ND statement printed on the author manuscript.",
   "maintainers_own": false,
   "found_by": "actuated-tip"
  },
  {
   "schema_version": 1,
   "id": "growing_mangan2025",
   "name": "Growing robot",
   "full_name": "Hybrid tendon-notched continuum robot + hydraulic everting (growing) robot",
   "group": "Morimoto (UCSD) with Hawkes (UCSB), Heit (Stanford)",
   "group_short": "UCSD / UCSB",
   "family": "tip",
   "category": "actuated-device",
   "first_year": 2025,
   "latest_year": 2025,
   "versions": "single (T-MRB 2025); 2021: VINE everting (growing) catheter, UCSB/UCSD/Stanford, same team (Li 2021 T-MRB) (Alekseeva 2025 Table 12 row 9, Fig. 19g) (alekseeva2025_design)",
   "target_anatomy": "neuro: type III aortic arch and extremely tortuous ICA benchtop models (mechanical thrombectomy)",
   "devices": [
    "catheter"
   ],
   "devices_driven": "own growing robot (2.67 mm OD, about 8 Fr) that pulls a commercial 5 Fr aspiration catheter (SOFIA); notched base 7.6 mm OD",
   "n_dof": null,
   "n_dof_detail": "notched base two segments, tendon-driven by 2 capstans; growth by fluid pressure; system roll and insertion",
   "translation_mechanism": "other",
   "translation_detail": "other: eversion by hydraulic pressure (35-40 kPa) plus linear actuator and friction drive for the aspiration catheter",
   "rotation_mechanism": "rotating-drive-unit",
   "rotation_detail": "system roll stage",
   "device_range": "growing robot length 445 mm (S8 citing mangan Sec. III-C)",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "pressure sensor on growth fluid; N.R. for tip force",
   "haptics_leader": "no",
   "imaging_compat": "N.R.",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "silicone arch and ICA models with two 360-degree loops of 7.3 mm radius; one full deployment in under 10 min with mock clot (Sec. VI-D, S8); no repeated-trial success rate found",
   "key_numbers": "growth pressure 35-40 kPa; housing withstands 85 kPa; steering error 9.9 +/- 1.2 % and 17.6 +/- 0.7 % of segment length (S8 citing Sec. VI-A); retraction buckles",
   "sim_model": "none found in text scanned (kinematics of notched robot and design optimisation reported; no simulator)",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "render",
    "source": "mangan2025_serially Fig. 5 (CAD of the watertight actuation subsystem)",
    "source_url": "https://doi.org/10.1109/tmrb.2025.3583160",
    "licence": "publisher copyright (IEEE)",
    "credit": "Mangan et al., IEEE Transactions on Medical Robotics and Bionics (2025), Fig. 5. publisher copyright (IEEE).",
    "edits": "native extract, no edits (labels and leader lines kept: they cross the motors, capstans and housing)",
    "file": null
   },
   "pictures": [
    {
     "id": "growing_mangan2025_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Full deployment in a benchtop model: arch, tortuous ICA, mock clot",
     "source_key": "mangan2025_serially",
     "source": "Mangan et al., IEEE Transactions on Medical Robotics and Bionics (2025), Fig. 11, p. 11",
     "source_url": "https://doi.org/10.1109/tmrb.2025.3583160",
     "where": "Fig. 11, p. 11",
     "licence": "publisher copyright"
    },
    {
     "id": "growing_mangan2025_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Notched robot and everting growing robot in arch and ICA phantoms",
     "source_key": "mangan2025_serially",
     "source": "Mangan et al., IEEE Transactions on Medical Robotics and Bionics (2025), Fig. 1, p. 2",
     "source_url": "https://doi.org/10.1109/tmrb.2025.3583160",
     "where": "Fig. 1, p. 2",
     "licence": "publisher copyright"
    },
    {
     "id": "growing_mangan2025_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Tendon-notched continuum robot in its watertight sleeve, bent",
     "source_key": "mangan2025_serially",
     "source": "Mangan et al., IEEE Transactions on Medical Robotics and Bionics (2025), Fig. 4(f), p. 5",
     "source_url": "https://doi.org/10.1109/tmrb.2025.3583160",
     "where": "Fig. 4(f), p. 5",
     "licence": "publisher copyright"
    },
    {
     "id": "growing_mangan2025_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Drawing of the hybrid tip: notched robot, growing robot, aspiration catheter",
     "source_key": "mangan2025_serially",
     "source": "Mangan et al., IEEE Transactions on Medical Robotics and Bionics (2025), Fig. 4(e), p. 5",
     "source_url": "https://doi.org/10.1109/tmrb.2025.3583160",
     "where": "Fig. 4(e), p. 5",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "mangan2025_serially",
     "doi": "10.1109/tmrb.2025.3583160",
     "url": null,
     "title": "Serially-Connected Soft Continuum Robots for Endovascular Emergencies",
     "year": 2025,
     "venue": "IEEE Transactions on Medical Robotics and Bionics"
    },
    {
     "key": "alekseeva2025_design",
     "doi": "10.1002/rob.22480",
     "url": null,
     "title": "The Design of Endovascular Robots for Cardiac Interventions: A Survey",
     "year": 2024,
     "venue": "Journal of Field Robotics"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full text downloaded; abstract, intro, hardware sections read, results via S8",
   "notes": "Affiliations are UCSD/UCSB/Stanford; brief mentioned UCSD/Stanford.",
   "maintainers_own": false,
   "found_by": "actuated-tip"
  },
  {
   "schema_version": 1,
   "id": "bellows_barnes2025",
   "name": "Bellows guidewire",
   "full_name": "Soft fluidic bellows guidewire with teleoperated drive and imitation-learning policy",
   "group": "Krieger lab, Johns Hopkins, with Sochol (University of Maryland)",
   "group_short": "Johns Hopkins",
   "family": "tip",
   "category": "actuated-device",
   "first_year": 2025,
   "latest_year": 2025,
   "versions": "arXiv 2510.09497 v2 (July 2026), submitted to IEEE",
   "target_anatomy": "neuro, large-scale (enlarged) 2D-projected bifurcation mazes",
   "devices": [
    "other"
   ],
   "devices_driven": "own 3D-printed fluid-driven soft robot, 5 mm bellows (large-scale analogue of a microguidewire, not a clinical size)",
   "n_dof": 2,
   "n_dof_detail": "2 (bending velocity, translation velocity)",
   "translation_mechanism": "tendon/tip-actuation",
   "translation_detail": "tendon/tip-actuation",
   "rotation_mechanism": "none",
   "rotation_detail": "none",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "force sensor in leader handle only (teleoperation); none on follower",
   "haptics_leader": "no force feedback; operator pushes a force-sensing handle, forces map proportionally to bend and translate velocity",
   "imaging_compat": "overhead camera converted to simulated fluoroscopy; no real X-ray",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "36 training mazes from 1584 possible, rearranged test set 3 mazes, novel test set 3 mazes; 647 demonstrations (218 normal, 429 recovery incl. DAgger)",
   "key_numbers": "83 % success on unseen layouts, 75 % on unseen patient-derived geometry (abstract); ablations 22 % to 61 % success; segmentation tip error 0.6 mm median, 1.9 mm 95th, 8.0 mm max",
   "sim_model": "no physics model; only a fluoroscopy rendering of camera frames (Sec. III-B)",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found: the policy trains on real teleoperated demonstrations with simulated fluoroscopy images; the paper contrasts itself with digital-twin-trained policies",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "photo",
    "source": "barnes2025_toward project page softrobotnavigation.github.io/resources/imgs/hardware_setup.png (middle panel: translation drive with bellows wire)",
    "source_url": "https://arxiv.org/abs/2510.09497",
    "licence": "project page image (authors), licence not stated",
    "credit": "Barnes et al., 2025. project page image (authors), licence not stated.",
    "edits": "crop; labels \"Fluidic tube\", \"Translation drive\" and an arrow erased (LaMa, mask of dark text pixels) then near-white residue set to white",
    "file": null
   },
   "pictures": [
    {
     "id": "bellows_barnes2025_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Leader handle with force sensor, syringe pump, translation drive and bellows tool",
     "source_key": "barnes2025_toward",
     "source": "Barnes et al. (2025), project page hardware_setup.png (= arXiv Fig. 2)",
     "source_url": "https://arxiv.org/abs/2510.09497",
     "where": "project page hardware_setup.png (= arXiv Fig. 2); https://softrobotnavigation.github.io/resources/imgs/hardware_setup.png",
     "licence": "author project page (terms not stated)"
    },
    {
     "id": "bellows_barnes2025_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Teleoperation control handle mounted on a six-axis force sensor",
     "source_key": "barnes2025_toward",
     "source": "Barnes et al. (2025), Fig. 2 (left), p. 3",
     "source_url": "https://arxiv.org/abs/2510.09497",
     "where": "Fig. 2 (left), p. 3",
     "licence": "arXiv non-exclusive distribution licence 1.0"
    },
    {
     "id": "bellows_barnes2025_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Soft fluidic-bellows microcatheter tip lit under UV, bent",
     "source_key": "barnes2025_toward",
     "source": "Barnes et al. (2025), Fig. 1 (top), p. 1",
     "source_url": "https://arxiv.org/abs/2510.09497",
     "where": "Fig. 1 (top), p. 1",
     "licence": "arXiv non-exclusive distribution licence 1.0"
    },
    {
     "id": "bellows_barnes2025_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Large-scale 3D-printed bellows tool navigating a 2D neurovascular maze",
     "source_key": "barnes2025_toward",
     "source": "Barnes et al. (2025), Fig. 1 (bottom right), p. 1",
     "source_url": "https://arxiv.org/abs/2510.09497",
     "where": "Fig. 1 (bottom right), p. 1",
     "licence": "arXiv non-exclusive distribution licence 1.0"
    },
    {
     "id": "bellows_barnes2025_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Large-scale bellows tool bent by fluid pressure",
     "source_key": "barnes2025_toward",
     "source": "Barnes et al. (2025), Fig. 2 (right), p. 3",
     "source_url": "https://arxiv.org/abs/2510.09497",
     "where": "Fig. 2 (right), p. 3",
     "licence": "arXiv non-exclusive distribution licence 1.0"
    }
   ],
   "sources": [
    {
     "key": "barnes2025_toward",
     "doi": null,
     "url": "https://arxiv.org/abs/2510.09497",
     "title": "Towards Autonomous Soft Robotic Endovascular Navigation via Imitation Learning",
     "year": 2025,
     "venue": null
    }
   ],
   "read_level": "full",
   "read_level_detail": "full",
   "notes": "Hardware is a large-scale analogue; quote the 5 mm bellows size next to any claim about neurovascular use.",
   "maintainers_own": false,
   "found_by": "actuated-tip"
  },
  {
   "schema_version": 1,
   "id": "hydraulic_gopesh2021",
   "name": "Hydraulic catheter",
   "full_name": "Hydraulic steerable microcatheter tip (hyperelastic, saline-driven chambers)",
   "group": "Friend lab, UC San Diego (Mechanical and Aerospace Engineering) with UCSD Neurosurgery, Radiology and Surgery; concept co-devised with Bernard Yan, Melbourne Brain Centre (gopesh2021_soft p. 1, 12)",
   "group_short": "UC San Diego",
   "family": "tip",
   "category": "actuated-device",
   "first_year": 2021,
   "latest_year": 2021,
   "versions": "Sci. Robotics 2021 (gopesh2021_soft); patent application US20190209811A1 'Hydraulically driven surgical apparatus'; Mooney-Rivlin constants in Gopesh and Friend, Soft Robot. 2020 (ref. 91); medRxiv preprint 2021.06.28.21258767",
   "target_anatomy": "neuro: in vivo external carotid -> ascending pharyngeal -> parotid artery with coil deployment in the parotid artery (not intracranial); PCOM aneurysm coiling in a silicone phantom (gopesh2021_soft p. 6-9)",
   "devices": [
    "guidewire",
    "microcatheter"
   ],
   "devices_driven": "own hydraulic microcatheter: 900 um outer diameter with four 50 um saline channels and a 400 um lumen, 15 mm steerable tip, 160 cm long Pebax shaft (gopesh2021_soft p. 3-5, 9); used through a 5 F guide with a 0.014-in Synchro2 micro-guidewire and AXIUM PRIME coils (p. 10)",
   "n_dof": null,
   "n_dof_detail": "3D tip orientation by pressurising one or more of four channels; no DOF count (gopesh2021_soft p. 1, 3)",
   "translation_mechanism": "tendon/tip-actuation",
   "translation_detail": "tendon/tip-actuation (hydraulic: four saline channels bend the tip; insertion by hand)",
   "rotation_mechanism": "none",
   "rotation_detail": "none reported: bending direction set by which channel is pressurised; shaft rotation N.R.",
   "device_range": "160 cm; 180-degree bend (curvature 400 1/m) at 350 kPa, rupture at 1200 kPa (gopesh2021_soft p. 4)",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "none",
   "haptics_leader": "no: handheld controller connected by microtubing (p. 9); in vivo a 1-ml syringe per channel locked with a one-way stopcock (p. 6); bench: Elveflow OB-1 pressure controller (p. 9)",
   "imaging_compat": "fluoroscopic roadmap (Siemens Artis Zeego); gold radiopaque markers at three positions and barium-filled Pebax (gopesh2021_soft p. 5, 10)",
   "sterility": "N.R.",
   "highest_validation": "animal",
   "validation_detail": "2 Yucatan miniature pigs (47 kg), one per acute terminal session (gopesh2021_soft p. 11): navigation external carotid -> ascending pharyngeal -> parotid artery and coil deployment; patient-derived silicone phantoms (femoral to ICA; ICA to a PCOM aneurysm) with pulsatile flow, trial count N.R.",
   "key_numbers": "180-degree bend at 350 kPa, rupture at 1200 kPa (safety factor about 4); response time < 1 s through 1.6 m of 50 um tubing; length-to-diameter ratio 10,000:1; no endothelial injury or perforation on angiography (gopesh2021_soft p. 3-10)",
   "sim_model": "ANSYS finite-element model of the tip (two-parameter Mooney-Rivlin) to choose channel radius and radial position; the channel count was fixed at four by the authors (gopesh2021_soft p. 4, 10)",
   "has_sim_model": true,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "photo",
    "source": "https://today.ucsd.edu/news_uploads/steerable_catheter_1.png (UCSD news release, today.ucsd.edu/story/bioinspired-steerable-catheter; right part: hydraulic tip photo)",
    "source_url": "https://today.ucsd.edu/news_uploads/steerable_catheter_1.png",
    "licence": "press image (UC San Diego), terms not stated",
    "credit": "https://today.ucsd.edu/news_uploads/steerable_catheter_1.png (UCSD news release, today.ucsd.edu/story/bioinspired-steerable-catheter; right part: hydraulic tip photo). Licence: press image (UC San Diego), terms not stated.",
    "edits": "crop removing the left fluoroscopy inset",
    "file": null
   },
   "pictures": [
    {
     "id": "hydraulic_gopesh2021_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Hyperelastic steerable tip: mold, fabricated tip and cross-section micrographs",
     "source_key": "gopesh2021_soft",
     "source": "Gopesh et al., Science Robotics (2021), Fig. 2(c-d), PMC9809155",
     "source_url": "https://doi.org/10.1126/scirobotics.abf0601",
     "where": "Fig. 2(c-d), PMC9809155",
     "licence": "publisher copyright (NIH author manuscript PMC9809155)"
    },
    {
     "id": "hydraulic_gopesh2021_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Tip fabrication steps from glass-rod mould to the finished four-channel tip",
     "source_key": "gopesh2021_soft",
     "source": "Gopesh et al., Science Robotics (2021), Fig. 7(A-M), p. 8",
     "source_url": "https://doi.org/10.1126/scirobotics.abf0601",
     "where": "Fig. 7(A-M), p. 8",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "gopesh2021_soft",
     "doi": "10.1126/scirobotics.abf0601",
     "url": null,
     "title": "Soft robotic steerable microcatheter for the endovascular treatment of cerebral disorders",
     "year": 2021,
     "venue": "Science Robotics"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (gopesh2021_soft)",
   "notes": "Hand-controlled: no bedside drive in the paper. The earlier '400 kPa' (web) is not in the paper; 350 kPa bends the tip 180 degrees. | X2 2026-11-08: raised to full text.",
   "maintainers_own": false,
   "found_by": "actuated-tip"
  },
  {
   "schema_version": 1,
   "id": "mitmagwire_kim2022",
   "name": "Magnetic soft wire",
   "full_name": "MIT telerobotic magnetic soft guidewire system",
   "group": "Zhao lab, MIT, with Massachusetts General Hospital / Harvard Medical School (neurosurgery), University of Cincinnati and Philips Research North America; animal work under UMass Medical School IACUC (kim2022_telerobotic affiliations, p. 18)",
   "group_short": "MIT",
   "family": "magnetic",
   "category": "magnetic-navigation",
   "first_year": 2019,
   "latest_year": 2022,
   "versions": "2019 ferromagnetic soft continuum robots: device only, magnet moved by hand and wire pushed by hand (kim2019_ferromagnetic); 2022 telerobotic system: KUKA arm with a 100 mm magnet, two motorised advancers, remote console, 400 um wire, pig (kim2022_telerobotic)",
   "target_anatomy": "neuro (phantoms, porcine brachial artery with accentuated tortuosity)",
   "devices": [
    "guidewire",
    "microcatheter",
    "sheath",
    "therapeutic-device"
   ],
   "devices_driven": "2 devices, driven independently or simultaneously: own magnetic soft guidewire, 400 um OD (tapered nitinol core in a TPU jacket with 20 vol% NdFeB, magnetically responsive distal 50 mm, coreless 4 mm tip) and a microcatheter; 0.0115-in coils and a Solitaire X stent retriever delivered through it; 7 F sheath (kim2022_telerobotic p. 3-4, 18); 2019 prototypes 600 um (PDMS + NdFeB, 80 um nitinol core) and 810 um (TPU + NdFeB) (kim2019_ferromagnetic)",
   "n_dof": 7,
   "n_dof_detail": "7-DOF arm (KUKA LBR Med 14 R820) sets the magnet pose (6-DOF end-effector control; pole flipped by turning axis 7 by 180 degrees) + 2 linear advancing units for wire and microcatheter (kim2022_telerobotic p. 3, 7, 17)",
   "translation_mechanism": "magnetic",
   "translation_detail": "magnetic (steering); insertion by two commercial worm-drive advancers (Stereotaxis QuikCAS Cardiodrive) driven by DC gearmotors through flexible shafts (kim2022_telerobotic p. 3, 18)",
   "rotation_mechanism": "magnetic-field",
   "rotation_detail": "field direction, no shaft rotation",
   "device_range": "magnet working distance d/R 2.64-3.67, i.e. 80-30 mT at the tip (kim2022_telerobotic p. 7)",
   "footprint_mm": "N.R. (arm on a mobile platform beside the operating table, kim2022_telerobotic p. 3)",
   "mass_kg": "magnet and fixture 7 kg (kim2022_telerobotic p. 18); arm N.R.",
   "force_sensing": "none: 'the advancing unit of our system does not provide any tactile or haptic feedback' (kim2022_telerobotic p. 17)",
   "haptics_leader": "no haptics: remote console a few metres away with a 6-DOF SpaceMouse Pro knob and buttons to advance/retract; ROS MoveIt/RViz virtual view (kim2022_telerobotic p. 17-18)",
   "imaging_compat": "real-time fluoroscopy, DSA roadmaps, 3D rotational angiography; the NdFeB particles make the wire radiopaque; compatible with standard biplane fluoroscopy (kim2022_telerobotic p. 8, 17)",
   "sterility": "N.R.",
   "highest_validation": "animal",
   "validation_detail": "head phantom under fluoroscopy (navigation 45.0 +- 4.0 s, n = 5); MCA aneurysm coiling and clot retrieval in phantoms (n = 3 each); 1 pig (56 kg Yorkshire, brachial-artery tortuosity model, 124.6 +- 19.7 s, n = 5); learning curve 6 novices and 2 experienced users x 15 trials; robot vs manual: one interventionalist, 10 trials each (kim2022_telerobotic pp. 8-16, 18)",
   "key_numbers": "robot vs manual 42.9 +- 10.5 vs 63.7 +- 22.4 s (P < 0.05); the manual wire crossed the siphon aneurysm in 5 of 10 trials; field at most 80 mT, gradient 1.75 mT/mm; N52 cylindrical magnet 100 mm diameter x 100 mm; tip deflection about 120 deg (attraction) and 90 deg (repulsion) (kim2022_telerobotic pp. 5-16)",
   "sim_model": "field maps in COMSOL; 2019 Abaqus finite-element model of the soft continuum robot (kim2019_ferromagnetic p. 13); MoveIt/RViz virtual scene used to plan magnet poses; magnet pose from joystick input via a Jacobian pseudo-inverse, no guidewire model in the loop (kim2022_telerobotic p. 17)",
   "has_sim_model": true,
   "sim2real": "none-found",
   "sim2real_detail": "none found (no learned controller in kim2019 or kim2022)",
   "picture": {
    "status": "not-cleared",
    "grade": "A",
    "kind": "photo",
    "source": "MIT News press image MIT-Robo-Stroke-02-press.jpg (left panel: robot arm with actuating magnet over the neurovascular phantom), news.mit.edu/sites/default/files/download/202204/",
    "source_url": null,
    "licence": "CC BY-NC-ND (MIT News terms: no alteration other than cropping; credit \"Courtesy of the researchers\")",
    "credit": "MIT News press image MIT-Robo-Stroke-02-press.jpg (left panel: robot arm with actuating magnet over the neurovascular phantom), news.mit.edu/sites/default/files/download/202204/. Licence: CC BY-NC-ND (MIT News terms: no alteration other than cropping; credit \"Courtesy of the researchers\").",
    "edits": "crop; 2 label areas on the plain black background set to black; white text \"Neurovascular Phantom\" over the phantom erased (LaMa, text mask only)",
    "file": null
   },
   "pictures": [
    {
     "id": "mitmagwire_kim2022_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Motorized guidewire and microcatheter advancement unit at the phantom inlet",
     "source_key": "kim2022_telerobotic",
     "source": "Kim et al., Science Robotics (2022), MIT News press image MIT-Robo-Stroke-02-press.jpg, right panel; news.mit.edu/sites/default/files/download/202204/",
     "source_url": "https://doi.org/10.1126/scirobotics.abg9907",
     "where": "MIT News press image MIT-Robo-Stroke-02-press.jpg, right panel; news.mit.edu/sites/default/files/download/202204/",
     "licence": "CC BY-NC-ND (MIT News press image; crop only)"
    },
    {
     "id": "mitmagwire_kim2022_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Renderings of the robot arm and magnet over a patient beside a C-arm",
     "source_key": "kim2022_telerobotic",
     "source": "Kim et al., Science Robotics (2022), MIT News press image MIT-Robo-Stroke-01-press.jpg, right panels",
     "source_url": "https://doi.org/10.1126/scirobotics.abg9907",
     "where": "MIT News press image MIT-Robo-Stroke-01-press.jpg, right panels",
     "licence": "CC BY-NC-ND (MIT News press image; crop only)"
    },
    {
     "id": "mitmagwire_kim2022_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "System drawing: 7-DOF arm with magnet, wire advancers and joystick console",
     "source_key": "kim2022_telerobotic",
     "source": "Kim et al., Science Robotics (2022), Fig. 2, PMC9254892",
     "source_url": "https://doi.org/10.1126/scirobotics.abg9907",
     "where": "Fig. 2, PMC9254892",
     "licence": "publisher copyright (NIH author manuscript PMC9254892)"
    },
    {
     "id": "mitmagwire_kim2022_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Overview drawing of the telerobotic platform on a mobile cart at the C-arm",
     "source_key": "kim2022_telerobotic",
     "source": "Kim et al., Science Robotics (2022), Fig. 1, PMC9254892",
     "source_url": "https://doi.org/10.1126/scirobotics.abg9907",
     "where": "Fig. 1, PMC9254892",
     "licence": "publisher copyright (NIH author manuscript PMC9254892)"
    },
    {
     "id": "mitmagwire_kim2022_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Arm placing the magnet over the head phantom under the C-arm: actual and virtual views",
     "source_key": "kim2022_telerobotic",
     "source": "Kim et al., Science Robotics (2022), Fig. 4(E-F), p. 8",
     "source_url": "https://doi.org/10.1126/scirobotics.abg9907",
     "where": "Fig. 4(E-F), p. 8",
     "licence": "publisher copyright"
    },
    {
     "id": "mitmagwire_kim2022_06",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Arm placing the magnet over the anaesthetised pig: virtual and actual views",
     "source_key": "kim2022_telerobotic",
     "source": "Kim et al., Science Robotics (2022), Fig. 7(E-F), p. 13",
     "source_url": "https://doi.org/10.1126/scirobotics.abg9907",
     "where": "Fig. 7(E-F), p. 13",
     "licence": "publisher copyright"
    },
    {
     "id": "mitmagwire_kim2022_07",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Drawing of the arm and magnet beside the C-arm around the porcine model",
     "source_key": "kim2022_telerobotic",
     "source": "Kim et al., Science Robotics (2022), Fig. 7(C), p. 13",
     "source_url": "https://doi.org/10.1126/scirobotics.abg9907",
     "where": "Fig. 7(C), p. 13",
     "licence": "publisher copyright"
    },
    {
     "id": "mitmagwire_kim2022_08",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Neurointerventionalist at the remote console and with a conventional guidewire for comparison",
     "source_key": "kim2022_telerobotic",
     "source": "Kim et al., Science Robotics (2022), Fig. 8(A), p. 15",
     "source_url": "https://doi.org/10.1126/scirobotics.abg9907",
     "where": "Fig. 8(A), p. 15",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "kim2022_telerobotic",
     "doi": "10.1126/scirobotics.abg9907",
     "url": null,
     "title": "Telerobotic neurovascular interventions with magnetic manipulation",
     "year": 2022,
     "venue": "Science Robotics"
    },
    {
     "key": "kim2019_ferromagnetic",
     "doi": "10.1126/scirobotics.aax7329",
     "url": null,
     "title": "Ferromagnetic soft continuum robots",
     "year": 2019,
     "venue": "Science Robotics"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (kim2019_ferromagnetic, kim2022_telerobotic)",
   "notes": "Highest-profile magnetic guidewire. Mount Sinai does not appear in either paper (corrected to MGH / Cincinnati / Philips). The earlier Dryad-based 0.72-0.91 mm diameter guess is replaced by the stated 400 um. | X2 2026-11-08: raised to full text.",
   "maintainers_own": false,
   "found_by": "actuated-tip"
  },
  {
   "schema_version": 1,
   "id": "helical_dreyfus2024",
   "name": "Helical magnetic",
   "full_name": "Dexterous helical magnetic robot (articulating magnetic tip + helical surface)",
   "group": "Nelson, Multi-Scale Robotics Lab, ETH Zurich (with Cantonal Hospital Aarau)",
   "group_short": "ETH Zurich",
   "family": "magnetic",
   "category": "magnetic-navigation",
   "first_year": 2024,
   "latest_year": 2024,
   "versions": "Sci. Robotics 2024; commercial successor is Nanoflex (A4 scope)",
   "target_anatomy": "neuro (aortic arch to millimetre-sized brain arteries; models and live pig)",
   "devices": [
    "catheter"
   ],
   "devices_driven": "own helical catheter-like robot; a news summary says under 1 mm diameter (secondary, unverified)",
   "n_dof": null,
   "n_dof_detail": "N.R.",
   "translation_mechanism": "magnetic",
   "translation_detail": "magnetic",
   "rotation_mechanism": "magnetic-field",
   "rotation_detail": "rotation turned into advance by helical ridge on wall contact",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "N.R.",
   "haptics_leader": "N.R.",
   "imaging_compat": "N.R.",
   "sterility": "N.R.",
   "highest_validation": "animal",
   "validation_detail": "models of human vasculature and blood vessels of a live pig (abstract); counts N.R.",
   "key_numbers": "N.R.",
   "sim_model": "N.R.",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found at abstract level",
   "picture": {
    "status": "cleared",
    "grade": "B",
    "kind": "drawing",
    "source": "dreyfus2024_dexterous accepted version (zenodo.org/records/10813540) Fig. 2 centre (eMNS beside the patient table, C-arm, advancer)",
    "source_url": "https://doi.org/10.1126/scirobotics.adh0298",
    "licence": "CC BY 4.0 (Zenodo record licence of the accepted manuscript; ETH Research Collection lists In Copyright for the same item)",
    "credit": "Dreyfus et al., Science Robotics (2024), Fig. 2. CC BY 4.0 (Zenodo record licence of the accepted manuscript; ETH Research Collection lists In Copyright for the same item).",
    "edits": "native extract (1332 px), circular inset fragments around the edge painted white, crop",
    "file": "pictures/helical_dreyfus2024.jpg"
   },
   "pictures": [
    {
     "id": "helical_dreyfus2024_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Navion eMNS beside a planar phantom with overhead camera, advancer and gamepad",
     "source_key": "dreyfus2022_simulation",
     "source": "Dreyfus et al., IEEE Robotics and Automation Letters (2022), Fig. 3, p. 3 (same group's eMNS and advancer, RA-L 2022)",
     "source_url": "https://doi.org/10.1109/lra.2022.3187249",
     "where": "Fig. 3, p. 3 (same group's eMNS and advancer, RA-L 2022)",
     "licence": "publisher copyright"
    },
    {
     "id": "helical_dreyfus2024_02",
     "status": "cleared",
     "file": "pictures/extra/helical_dreyfus2024_02.jpg",
     "thumb": "pictures/thumbs/helical_dreyfus2024_02.jpg",
     "kind": "in-use",
     "caption": "Helical robot navigating trans-radial, trans-femoral and aneurysm phantom routes",
     "source_key": "dreyfus2024_dexterous",
     "source": "Dreyfus et al., Science Robotics (2024), Fig. 5(B-E), accepted version p. 31",
     "source_url": "https://doi.org/10.1126/scirobotics.adh0298",
     "where": "Fig. 5(B-E), accepted version p. 31",
     "licence": "CC BY 4.0 (Zenodo 10813540 accepted version)"
    },
    {
     "id": "helical_dreyfus2024_03",
     "status": "cleared",
     "file": "pictures/extra/helical_dreyfus2024_03.jpg",
     "thumb": "pictures/thumbs/helical_dreyfus2024_03.jpg",
     "kind": "render",
     "caption": "Drawing of the helical guidewire, microcatheter and motorized advancer",
     "source_key": "dreyfus2024_dexterous",
     "source": "Dreyfus et al., Science Robotics (2024), Fig. 3, accepted version p. 29",
     "source_url": "https://doi.org/10.1126/scirobotics.adh0298",
     "where": "Fig. 3, accepted version p. 29",
     "licence": "CC BY 4.0 (Zenodo 10813540 accepted version)"
    },
    {
     "id": "helical_dreyfus2024_04",
     "status": "cleared",
     "file": "pictures/extra/helical_dreyfus2024_04.jpg",
     "thumb": "pictures/thumbs/helical_dreyfus2024_04.jpg",
     "kind": "render",
     "caption": "Exploded drawing of the advancer: friction drive wheel, guiding insert, motor",
     "source_key": "dreyfus2024_dexterous",
     "source": "Dreyfus et al., Science Robotics (2024), Fig. S1, accepted version p. 38",
     "source_url": "https://doi.org/10.1126/scirobotics.adh0298",
     "where": "Fig. S1, accepted version p. 38",
     "licence": "CC BY 4.0 (Zenodo 10813540 accepted version)"
    }
   ],
   "sources": [
    {
     "key": "dreyfus2024_dexterous",
     "doi": "10.1126/scirobotics.adh0298",
     "url": null,
     "title": "Dexterous helical magnetic robot for improved endovascular access",
     "year": 2024,
     "venue": "Science Robotics"
    }
   ],
   "read_level": "abstract",
   "read_level_detail": "abstract / web",
   "notes": "Accepted version exists at research-collection.ethz.ch (bitstream 659728); needs manual download.",
   "maintainers_own": false,
   "found_by": "actuated-tip"
  },
  {
   "schema_version": 1,
   "id": "cardiomag_fischer2022",
   "name": "CardioMag",
   "full_name": "CardioMag eMNS with magnetic catheter and magnetic localisation (ETH)",
   "group": "Nelson, ETH Zurich (Fischer, Boehler)",
   "group_short": "ETH Zurich",
   "family": "magnetic",
   "category": "magnetic-navigation",
   "first_year": 2022,
   "latest_year": 2022,
   "versions": "single (RA-L 2022); same eMNS platform as Navion's academic origin; 2017-19: ETH (Nelson) magnetic catheters in Aeon Phocus: tethered magnet catheter with force and 5-DOF pose control (Chautems 2017 ICRA) and variable-stiffness 2- and 3-segment catheters (Chautems 2017 IROS; 2019 Adv. Intell. Syst.) (Hwang 2020 Figs. 8a, 8g) (hwang2020_review)",
   "target_anatomy": "endoluminal, 2D vascular models (24 mm and 11 mm channels)",
   "devices": [
    "catheter"
   ],
   "devices_driven": "own catheter: OD 2.8 mm / ID 2 mm Flexan tube with 3 mm OD x 6 mm permanent magnet at tip, Hall sensor 12 mm behind magnet",
   "n_dof": null,
   "n_dof_detail": "field direction and gradient from 8 electromagnets; advance by Maxon-motor catheter advancer at 10 mm/s",
   "translation_mechanism": "magnetic",
   "translation_detail": "magnetic",
   "rotation_mechanism": "magnetic-field",
   "rotation_detail": "field direction",
   "device_range": "N.R.",
   "footprint_mm": "eMNS about 0.3 m scale bar in Fig. 1 (size N.R. in text)",
   "mass_kg": "N.R.",
   "force_sensing": "Hall-effect sensor for localisation (range +/- 36 mT per axis), no force sensing",
   "haptics_leader": "no",
   "imaging_compat": "localisation from magnetic field; fluoroscopy minimised; overhead camera as ground truth",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "2D vascular models a and b; catheter navigated through all branches; localisation tested over 40 trials on path 1-3 of model a",
   "key_numbers": "eMNS fields 20 mT, gradient 0.15 mT/mm; mean localisation error 3.64 mm (sd 1.61) model b, 2.74 mm with extra field change; model a mean 7.94 mm (sd 2.94), 5.65 mm with extra gradient; position estimate 38.3 ms",
   "sim_model": "linear model of the eMNS (coil currents to field), calibrated; no physics simulator of the catheter",
   "has_sim_model": true,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "A",
    "kind": "photo",
    "source": "fischer2022_using Fig. 3(a) (setup inside CardioMag: advancer, catheter, phantom between the coils)",
    "source_url": "https://doi.org/10.1109/lra.2022.3181420",
    "licence": "publisher copyright (IEEE)",
    "credit": "Fischer et al., IEEE Robotics and Automation Letters (2022), Fig. 3(a). publisher copyright (IEEE).",
    "edits": "native extract, crop left panel only",
    "file": null
   },
   "pictures": [
    {
     "id": "cardiomag_fischer2022_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Rendering of the CardioMag electromagnetic navigation system",
     "source_key": "fischer2022_using",
     "source": "Fischer et al., IEEE Robotics and Automation Letters (2022), Fig. 1(a), p. 2",
     "source_url": "https://doi.org/10.1109/lra.2022.3181420",
     "where": "Fig. 1(a), p. 2",
     "licence": "publisher copyright"
    },
    {
     "id": "cardiomag_fischer2022_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Magnetic catheter in the vascular model: overhead camera and RViz overlay",
     "source_key": "fischer2022_using",
     "source": "Fischer et al., IEEE Robotics and Automation Letters (2022), Fig. 3(b-c), p. 3",
     "source_url": "https://doi.org/10.1109/lra.2022.3181420",
     "where": "Fig. 3(b-c), p. 3",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "fischer2022_using",
     "doi": "10.1109/lra.2022.3181420",
     "url": null,
     "title": "Using Magnetic Fields to Navigate and Simultaneously Localize Catheters in Endoluminal Environments",
     "year": 2022,
     "venue": "IEEE Robotics and Automation Letters"
    },
    {
     "key": "hwang2020_review",
     "doi": "10.1007/s11370-020-00311-0",
     "url": null,
     "title": "A review of magnetic actuation systems and magnetically actuated guidewire- and catheter-based microrobots for vascular interventions",
     "year": 2020,
     "venue": "Intelligent Service Robotics"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full",
   "notes": "Centre-line automation plus localisation from field only. Commercial Navion is A4's.",
   "maintainers_own": false,
   "found_by": "actuated-tip"
  },
  {
   "schema_version": 1,
   "id": "armm_heunis2020",
   "name": "ARMM",
   "full_name": "ARMM (Advanced Robotics for Magnetic Manipulation)",
   "group": "Misra, Surgical Robotics Lab, University of Twente",
   "group_short": "U. Twente",
   "family": "magnetic",
   "category": "magnetic-navigation",
   "first_year": 2019,
   "latest_year": 2020,
   "versions": "single (RA-L 2020); coil optimisation in Sikorski 2019 (cited, not read); 2016: Twente (Misra) magnetically actuated catheter in closed loop on 2D ultrasound (Boskma, Scheggi, Misra 2016 BioRob) (Alekseeva 2025 Table 12 row 6) (alekseeva2025_design)",
   "target_anatomy": "iliac / aortic phantom from CT of a 62-year-old (gelatin torso phantom, pulsating flow)",
   "devices": [
    "catheter"
   ],
   "devices_driven": "commercial Sherpa NX Active 2 mm coronary guide catheter (500 mm) with five NdFeB magnets (2 mm x 2 mm) in the tip",
   "n_dof": null,
   "n_dof_detail": "two UR manipulators (UR10 carries the electromagnetic coil, UR5 carries the ultrasound probe) plus a 1-axis catheter insertion device",
   "translation_mechanism": "magnetic",
   "translation_detail": "magnetic (steering); separate insertion device, servo-driven gear and bearing, 1.3-6.4 mm/s, takes 3-34 Fr",
   "rotation_mechanism": "magnetic-field",
   "rotation_detail": "coil pose, no shaft rotation",
   "device_range": "500 mm catheter",
   "footprint_mm": "workspace sphere radius 783 mm (max 1300 mm); 9 m3 environment",
   "mass_kg": "N.R.",
   "force_sensing": "none; tip tracked by ultrasound (30 Hz) and motion capture",
   "haptics_leader": "no",
   "imaging_compat": "3D ultrasound feedback, optical motion capture; radiation-free",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "gelatin torso phantom with pulsating flow, 3D targets, PI control; target count N.R. in my read",
   "key_numbers": "coil at least 20 mT and over 0.6 mT/mm at 50-200 mm; mean tip error 2.09 +/- 0.49 mm; median time to target 32.6 s",
   "sim_model": "none found (dipole-field actuation model; no simulator)",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "A",
    "kind": "photo",
    "source": "U-Today 2021-06-28 \"Robot for surgeries inside blood vessels\", photo by Hans Wolkers: https://www.utoday.nl/uploads/images/2021/week26/_Z723444.jpg (UR arm with electromagnet over the torso phantom, researcher operating)",
    "source_url": "https://www.utoday.nl/uploads/images/2021/week26/_Z723444.jpg",
    "licence": "press image (U-Today / Hans Wolkers), terms not stated",
    "credit": "U-Today 2021-06-28 \"Robot for surgeries inside blood vessels\", photo by Hans Wolkers: https://www.utoday.nl/uploads/images/2021/week26/_Z723444.jpg (UR arm with electromagnet over the torso phantom, researcher operating). Licence: press image (U-Today / Hans Wolkers), terms not stated.",
    "edits": "downscaled 50 % from 5315 px (no crop); not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "armm_heunis2020_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Electromagnet coil with cooling fans on the UR arm end-effector",
     "source_key": "heunis2020_armm",
     "source": "Heunis et al., IEEE Robotics and Automation Letters (2020), U-Today 2021-06-28 photo by Hans Wolkers, (cropped to the coil)",
     "source_url": "https://doi.org/10.1109/lra.2020.2965077",
     "where": "U-Today 2021-06-28 photo by Hans Wolkers, https://www.utoday.nl/uploads/images/2021/week26/_Z723495.jpg (cropped to the coil)",
     "licence": "press image (U-Today / Hans Wolkers)"
    },
    {
     "id": "armm_heunis2020_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "ARMM in a clinical-style setting: UR arms with coil and US probe over a torso",
     "source_key": "heunis2020_armm",
     "source": "Heunis et al., IEEE Robotics and Automation Letters (2020), Fig. 1, p. 1",
     "source_url": "https://doi.org/10.1109/lra.2020.2965077",
     "where": "Fig. 1, p. 1",
     "licence": "publisher copyright"
    },
    {
     "id": "armm_heunis2020_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Rendering of the electromagnetic coil and the force-sensed ultrasound transducer over the phantom",
     "source_key": "heunis2020_armm",
     "source": "Heunis et al., IEEE Robotics and Automation Letters (2020), Fig. 4 (right), p. 5",
     "source_url": "https://doi.org/10.1109/lra.2020.2965077",
     "where": "Fig. 4 (right), p. 5",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "heunis2020_armm",
     "doi": "10.1109/lra.2020.2965077",
     "url": null,
     "title": "The ARMM System - Autonomous Steering of Magnetically-Actuated Catheters: Towards Endovascular Applications",
     "year": 2020,
     "venue": "IEEE Robotics and Automation Letters"
    },
    {
     "key": "alekseeva2025_design",
     "doi": "10.1002/rob.22480",
     "url": null,
     "title": "The Design of Endovascular Robots for Cardiac Interventions: A Survey",
     "year": 2024,
     "venue": "Journal of Field Robotics"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full",
   "notes": "Mobile electromagnet on a robot arm; not a clinical room install.",
   "maintainers_own": false,
   "found_by": "actuated-tip"
  },
  {
   "schema_version": 1,
   "id": "siatguidewire_zhang2022",
   "name": "Magnet gantry",
   "full_name": "SIAT magnetically steerable guidewire: two-sided permanent-magnet gantry (2022) and arm-held magnet with a guidewire advancer (2023)",
   "group": "Tiantian Xu group, Shenzhen Institutes of Advanced Technology (CAS), with the SIAT-CUHK joint lab / CUHK (Li Zhang) and the Department of Neurosurgery, South China Hospital of Shenzhen University (xu2023_magnetically)",
   "group_short": "SIAT",
   "family": "magnetic",
   "category": "magnetic-navigation",
   "first_year": 2022,
   "latest_year": 2023,
   "versions": "2022 RA-L 3D steering system, two-sided permanent-magnet gantry, guidewire fed by hand (zhang2022_magnetic); 2022 RCAR paper of Fu et al. (cited as xu2023 ref. 36; not read); 2023 Adv. Intell. Syst. (Fu ... Du, Xu): UR10 arm carrying a D50 x L25 mm N52 magnet with a pole-flip stepper on a mobile cart, 4-DOF guidewire/catheter advancer, new tip, dipole + Cosserat models, trajectory planning, DSA test (xu2023_magnetically, full)",
   "target_anatomy": "2022: peripheral phantoms (silicone thigh vessels ID 1 mm to 1.6 cm); 2023: femoral artery -> aortic arch -> carotid -> intracranial arteries in a 959 mm silicone phantom (xu2023_magnetically Sec. 3.4)",
   "devices": [
    "guidewire",
    "catheter"
   ],
   "devices_driven": "2022: commercial hydrophilic guidewire (LWSTDA35150) joined to an Ecoflex + NdFeB (1:1 mass) soft actuator 2.5 cm long and 1.9 mm in diameter; 2023: 0.035-in (0.89 mm) commercial guidewire with two axially magnetised 0.5 x 2.5 mm N52 NdFeB magnets in a PDMS-filled silicone tube (0.5/1 mm ID/OD); the advancer takes 0.3-5 mm devices (guidewire and catheter), only the guidewire moved in the experiments (xu2023_magnetically Sec. 2.1)",
   "n_dof": null,
   "n_dof_detail": "2022: two symmetric gantries, each three linear motors (x, y, z) carrying a rectangular permanent magnet; 2023: 6-DOF UR10 arm + pole-flip stepper; guidewire and catheter advancers with 4 DOF in total (xu2023_magnetically Sec. 2.1)",
   "translation_mechanism": "magnetic",
   "translation_detail": "magnetic (steering); 2022 forward push by hand; 2023 advancer: stepper-driven friction-wheel pair with a spring/screw clamp (xu2023_magnetically p. 4, Fig. S1)",
   "rotation_mechanism": "magnetic-field",
   "rotation_detail": "field direction; 2023 advancer rotates its linear module with a stepper and gear pair (xu2023_magnetically p. 4)",
   "device_range": "2023: advance speed 0-15 mm/s; magnet distance 40-180 mm (xu2023_magnetically p. 4, 8)",
   "footprint_mm": "2022 system 880 x 620 x 1600; workspace 700 x 500 x 500; 2023 mobile cart, dimensions N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "none",
   "haptics_leader": "no; 2023 teleoperation console with an Xbox joystick through ROS (xu2023_magnetically Sec. 3.4)",
   "imaging_compat": "camera in 2022 and on the 2023 bench; 2023 Philips Azurion 7M20 DSA in a cath room, system operated from outside the room (xu2023_magnetically p. 12-13)",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "2022: ring-passing task (8 mm rings) and path following, 3D vascular phantom; 2023: trajectory following in 3 resin phantoms (ID 10-13 mm, 160-180 mm long), teleoperated navigation to 4 intracranial targets in a 959 mm silicone phantom with pulsatile flow, one path under DSA in the partner hospital's cath room; repeat counts N.R.; pig tests named as future work (xu2023_magnetically Sec. 3)",
   "key_numbers": "2022: field 0-20 mT; deflection up to 180 degrees; localisation accuracy 8 mm (ring diameter). 2023: mean tip position error 1.52-1.88 mm and tip angle error 2.36-2.57 degrees over 3 phantoms; deflection up to about 100 degrees; navigation within 1-2 min; advance speeds 1.2-6.06 mm/s (xu2023_magnetically Sec. 3.3)",
   "sim_model": "2022 kinematic model; 2023 dipole field model, constant-curvature beam and Cosserat rod models (MATLAB bvp5c), COMSOL 5.6 field and tip FEM (xu2023_magnetically Sec. 2-3)",
   "has_sim_model": true,
   "sim2real": "yes",
   "sim2real_detail": "yes: luo2025_rlmg (RCAR 2025, full; found by W5): DDPG trained in SOFA+BeamAdapter, UR5 + permanent magnet + this advancer; 4 paths x 3 trials in a femoral-artery phantom; error 2.2-3.1 mm sim -> 2.8-3.8 mm real, time 7-13 s -> 31-67 s (Table I); no success rate",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "photo",
    "source": "zhang2022_magnetic Fig. 1(b) (two-sided permanent-magnet gantry with phantom)",
    "source_url": "https://doi.org/10.1109/lra.2022.3146909",
    "licence": "publisher copyright (IEEE)",
    "credit": "Zhang et al., IEEE Robotics and Automation Letters (2022), Fig. 1(b). publisher copyright (IEEE).",
    "edits": "native extract; crop; 9 red text labels + red arrows and a yellow outline erased (LaMa by colour mask), grey ghosts on the white background flattened, one yellow line inpainted (OpenCV Telea)",
    "file": null
   },
   "pictures": [
    {
     "id": "siatguidewire_zhang2022_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Guidewire passing through a set of rings steered by the magnet gantry",
     "source_key": "zhang2022_magnetic",
     "source": "Zhang et al., IEEE Robotics and Automation Letters (2022), Fig. 8, p. 5",
     "source_url": "https://doi.org/10.1109/lra.2022.3146909",
     "where": "Fig. 8, p. 5",
     "licence": "publisher copyright"
    },
    {
     "id": "siatguidewire_zhang2022_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Guidewire following three planned paths in a vascular phantom, time series",
     "source_key": "zhang2022_magnetic",
     "source": "Zhang et al., IEEE Robotics and Automation Letters (2022), Fig. 10, p. 6",
     "source_url": "https://doi.org/10.1109/lra.2022.3146909",
     "where": "Fig. 10, p. 6",
     "licence": "publisher copyright"
    },
    {
     "id": "siatguidewire_zhang2022_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Soft magnetic actuator at the guidewire tip bending under 1 to 20 mT",
     "source_key": "zhang2022_magnetic",
     "source": "Zhang et al., IEEE Robotics and Automation Letters (2022), Fig. 6, p. 5",
     "source_url": "https://doi.org/10.1109/lra.2022.3146909",
     "where": "Fig. 6, p. 5",
     "licence": "publisher copyright"
    },
    {
     "id": "siatguidewire_zhang2022_04",
     "status": "cleared",
     "file": "pictures/extra/siatguidewire_zhang2022_04.jpg",
     "thumb": "pictures/thumbs/siatguidewire_zhang2022_04.jpg",
     "kind": "render",
     "caption": "2023 system concept: arm-held magnet on a mobile cart, wire/catheter advancer, console (labelled)",
     "source_key": "xu2023_magnetically",
     "source": "Fu et al., Advanced Intelligent Systems (2023), Fig. 1(b), p. 3",
     "source_url": "https://doi.org/10.1002/aisy.202300267",
     "where": "Fig. 1(b), p. 3",
     "licence": "CC BY (Creative Commons Attribution License, version not printed)"
    },
    {
     "id": "siatguidewire_zhang2022_05",
     "status": "cleared",
     "file": "pictures/extra/siatguidewire_zhang2022_05.jpg",
     "thumb": "pictures/thumbs/siatguidewire_zhang2022_05.jpg",
     "kind": "setup",
     "caption": "In-vitro setup: arm-held magnet, pulsatile pumps, 3D phantom and guidewire advancer (labelled)",
     "source_key": "xu2023_magnetically",
     "source": "Fu et al., Advanced Intelligent Systems (2023), Fig. 5(a), p. 12",
     "source_url": "https://doi.org/10.1002/aisy.202300267",
     "where": "Fig. 5(a), p. 12",
     "licence": "CC BY (Creative Commons Attribution License, version not printed)"
    },
    {
     "id": "siatguidewire_zhang2022_06",
     "status": "cleared",
     "file": "pictures/extra/siatguidewire_zhang2022_06.jpg",
     "thumb": "pictures/thumbs/siatguidewire_zhang2022_06.jpg",
     "kind": "in-use",
     "caption": "System on a mobile cart beside the bed under DSA in a catheterisation room",
     "source_key": "xu2023_magnetically",
     "source": "Fu et al., Advanced Intelligent Systems (2023), Fig. 6(a), p. 13",
     "source_url": "https://doi.org/10.1002/aisy.202300267",
     "where": "Fig. 6(a), p. 13",
     "licence": "CC BY (Creative Commons Attribution License, version not printed)"
    },
    {
     "id": "siatguidewire_zhang2022_07",
     "status": "cleared",
     "file": "pictures/extra/siatguidewire_zhang2022_07.jpg",
     "thumb": "pictures/thumbs/siatguidewire_zhang2022_07.jpg",
     "kind": "setup",
     "caption": "Trajectory-following platform: arm-held magnet, phantom, cameras and guidewire advancer (labelled)",
     "source_key": "xu2023_magnetically",
     "source": "Fu et al., Advanced Intelligent Systems (2023), Fig. 4(a), p. 10",
     "source_url": "https://doi.org/10.1002/aisy.202300267",
     "where": "Fig. 4(a), p. 10",
     "licence": "CC BY (Creative Commons Attribution License, version not printed)"
    }
   ],
   "sources": [
    {
     "key": "zhang2022_magnetic",
     "doi": "10.1109/lra.2022.3146909",
     "url": null,
     "title": "Design and Characteristics of 3D Magnetically Steerable Guidewire System for Minimally Invasive Surgery",
     "year": 2022,
     "venue": "IEEE Robotics and Automation Letters"
    },
    {
     "key": "xu2023_magnetically",
     "doi": "10.1002/aisy.202300267",
     "url": null,
     "title": "A Magnetically Controlled Guidewire Robot System with Steering and Propulsion Capabilities for Vascular Interventional Surgery",
     "year": 2023,
     "venue": "Advanced Intelligent Systems"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (zhang2022_magnetic, xu2023_magnetically)",
   "notes": "2026-10-13 coordinator: sim2real corrected from 'none found' (W5_notes.md item 1). | X2 2026-11-08: xu2023 (Wiley, CC BY) received by hand and read in full; first author is Fu (key xu2023_magnetically kept); validation stays phantom; luo2025_rlmg used a UR5, xu2023 a UR10 (same group, different arm).",
   "maintainers_own": false,
   "found_by": "actuated-tip"
  },
  {
   "schema_version": 1,
   "id": "cuhkmobileem_yang2021",
   "name": "Mobile coils + US",
   "full_name": "Three-electromagnet parallel mechanism with US probe for guidewire steering",
   "group": "Zhang, CUHK Mechanical and Automation Engineering",
   "group_short": "CUHK",
   "family": "magnetic",
   "category": "magnetic-navigation",
   "first_year": 2021,
   "latest_year": 2021,
   "versions": "single (RA-L 2021)",
   "target_anatomy": "abdominal/peripheral phantom (bifurcated 5 mm ID silicone channel)",
   "devices": [
    "guidewire"
   ],
   "devices_driven": "own replica-moulded guidewire: 50 um nitinol wire, PDMS cannula 1 mm OD, NdFeB magnet 1.2 mm OD x 2 mm at tip",
   "n_dof": null,
   "n_dof_detail": "parallel mechanism of three electromagnets and US probe; 1-axis motorised feeder (1-15 mm/s, devices 0.5-5 mm)",
   "translation_mechanism": "magnetic",
   "translation_detail": "magnetic (steering) + motorised feeder",
   "rotation_mechanism": "magnetic-field",
   "rotation_detail": "field direction",
   "device_range": "N.R.",
   "footprint_mm": "cylindrical workspace 500 mm diameter",
   "mass_kg": "N.R.",
   "force_sensing": "none",
   "haptics_leader": "no",
   "imaging_compat": "B-mode US at 22 Hz for tracking (radiation-free)",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "three paths x three trials, tip reached target in all trials",
   "key_numbers": "30 mT per electromagnet at 100 mm, 12 mT omnidirectional at 100 mm; mean tip error 1.79 mm; speed 3.08 mm/s; kinematic modelling error 0.89 mm; field kept at 5 mT during run",
   "sim_model": "constant-curvature kinematic model with corrective angle (full)",
   "has_sim_model": true,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "photo",
    "source": "yang2021_magnetic Fig. 8(b) (parallel mechanism with three electromagnets)",
    "source_url": "https://doi.org/10.1109/lra.2021.3057295",
    "licence": "publisher copyright (IEEE)",
    "credit": "Yang et al., IEEE Robotics and Automation Letters (2021), Fig. 8(b). publisher copyright (IEEE).",
    "edits": "native extract, crop",
    "file": null
   },
   "pictures": [
    {
     "id": "cuhkmobileem_yang2021_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Three electromagnets and ultrasound probe over the water-tank phantom with feeder",
     "source_key": "yang2021_magnetic",
     "source": "Yang et al., IEEE Robotics and Automation Letters (2021), Fig. 8(a), p. 7",
     "source_url": "https://doi.org/10.1109/lra.2021.3057295",
     "where": "Fig. 8(a), p. 7",
     "licence": "publisher copyright"
    },
    {
     "id": "cuhkmobileem_yang2021_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Concept rendering: parallel electromagnet mechanism with US probe above a patient",
     "source_key": "yang2021_magnetic",
     "source": "Yang et al., IEEE Robotics and Automation Letters (2021), Fig. 1, p. 2",
     "source_url": "https://doi.org/10.1109/lra.2021.3057295",
     "where": "Fig. 1, p. 2",
     "licence": "publisher copyright"
    },
    {
     "id": "cuhkmobileem_yang2021_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Guidewire tip deflection under rotating external fields, image series",
     "source_key": "yang2021_magnetic",
     "source": "Yang et al., IEEE Robotics and Automation Letters (2021), Fig. 7, p. 6",
     "source_url": "https://doi.org/10.1109/lra.2021.3057295",
     "where": "Fig. 7, p. 6",
     "licence": "publisher copyright"
    },
    {
     "id": "cuhkmobileem_yang2021_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Structure of the magnetic guidewire: magnet segment, spring and core",
     "source_key": "yang2021_magnetic",
     "source": "Yang et al., IEEE Robotics and Automation Letters (2021), Fig. 2(a), p. 2",
     "source_url": "https://doi.org/10.1109/lra.2021.3057295",
     "where": "Fig. 2(a), p. 2",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "yang2021_magnetic",
     "doi": "10.1109/lra.2021.3057295",
     "url": null,
     "title": "Magnetic Control of a Steerable Guidewire Under Ultrasound Guidance Using Mobile Electromagnets",
     "year": 2021,
     "venue": "IEEE Robotics and Automation Letters"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full",
   "notes": "Crop clips panel (b) at its right edge.",
   "maintainers_own": false,
   "found_by": "actuated-tip"
  },
  {
   "schema_version": 1,
   "id": "msrc_wu2023",
   "name": "MSRC",
   "full_name": "Magnetically steerable robotic catheter with integrated magnetic localisation",
   "group": "Lei Zhou and Farshid Alambeigi (both UT Austin in mohanraj2022; Zhou at Univ. Wisconsin-Madison in wu2023)",
   "group_short": "Wisconsin / UT",
   "family": "magnetic",
   "category": "magnetic-navigation",
   "first_year": 2022,
   "latest_year": 2023,
   "versions": "2022 BioRob: kirigami heat-shrink catheter, Helmholtz pair and friction-drive feeder, manual knobs (mohanraj2022_kirigami, full) -> 2023 RA-L: integrated magnetic localisation (wu2023_integrated)",
   "target_anatomy": "peripheral arterial disease (lower-limb phantoms: Y 20 deg, S-shaped, 30 deg branch)",
   "devices": [
    "catheter"
   ],
   "devices_driven": "Cook G11430 catheter with 40 mm flexure-patterned heat-shrink distal end (3.2 mm pre-shrink OD), tip stack of N52 ring magnets 3 mm OD / 1.6 mm ID / 6 mm",
   "n_dof": 2,
   "n_dof_detail": "2 (insertion and planar steering; mohanraj2022 Sec. I, II-B); hardware: Helmholtz pair (220 mm diameter, 120 turns, up to 11 A) steering; friction-drive feeder on stepper",
   "translation_mechanism": "magnetic",
   "translation_detail": "magnetic (steering) + friction-drive feeder (drive wheel with a thick urethane layer, NEMA 17 stepper, spring preload; mohanraj2022 Sec. II-C, III-A)",
   "rotation_mechanism": "magnetic-field",
   "rotation_detail": "field direction",
   "device_range": "N.R.",
   "footprint_mm": "Helmholtz 220 mm diameter, 110 mm spacing",
   "mass_kg": "N.R.",
   "force_sensing": "16 three-axis magnetoresistive sensors (QMC5883L) locate the tip",
   "haptics_leader": "no (human operator controls insertion)",
   "imaging_compat": "fluoroscopy only at bifurcations; digital microscope in bench tests",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "three 3D-printed phantoms; catheter navigates under steering plus localisation; trial counts N.R.",
   "key_numbers": "mean position estimate error 0.95 mm after calibration; latency 400 ms mohanraj2022: 25 mT steering field at 13 A (power-supply limit); maximum tip deflection 12 mm; calculated pushing force 8 N (Sec. III-A, IV); one navigation through a 25 deg bifurcation of a leg phantom in 20 s (Sec. III-B, Fig. 9).",
   "sim_model": "mohanraj2022: analytical Helmholtz-field and dipole-torque model, Ansys Maxwell 3D finite elements for field and torque, SolidWorks finite elements for the flexure bending; tip displacement FE vs experiment RMSE 0.575 and 0.328 mm (Sec. II, IV, Figs. 4, 6)",
   "has_sim_model": true,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "photo",
    "source": "wu2023_integrated Fig. 6 centre (Helmholtz coils with 16-sensor array, catheter feed box)",
    "source_url": "https://doi.org/10.1109/lra.2023.3295297",
    "licence": "publisher copyright (IEEE)",
    "credit": "Wu et al., IEEE Robotics and Automation Letters (2023), Fig. 6. publisher copyright (IEEE).",
    "edits": "native extract (4242 px); crop; 7 labels erased and 4 leader lines erased (LaMa), one of which ran over the white coil face to a sensor; sensor-frame inset and axis triad on white background painted white",
    "file": null
   },
   "pictures": [
    {
     "id": "msrc_wu2023_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Catheter navigating a 3D-printed bifurcation phantom with localization on and off",
     "source_key": "wu2023_integrated",
     "source": "Wu et al., IEEE Robotics and Automation Letters (2023), Fig. 10, p. 7",
     "source_url": "https://doi.org/10.1109/lra.2023.3295297",
     "where": "Fig. 10, p. 7",
     "licence": "publisher copyright"
    },
    {
     "id": "msrc_wu2023_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Earlier setup: Helmholtz coils, friction-drive feeder, control box and microscope",
     "source_key": "mohanraj2022_kirigami",
     "source": "Mohanraj et al., 2022 9th IEEE RAS/EMBS International Conference for Biomedical Robotics and Biomechatronics (BioRob) (2022), Fig. 7, p. 5",
     "source_url": "https://doi.org/10.1109/biorob52689.2022.9925350",
     "where": "Fig. 7, p. 5",
     "licence": "publisher copyright"
    },
    {
     "id": "msrc_wu2023_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Digital-microscope snapshots of the catheter steering into a branch",
     "source_key": "wu2023_integrated",
     "source": "Wu et al., IEEE Robotics and Automation Letters (2023), Fig. 9, p. 7",
     "source_url": "https://doi.org/10.1109/lra.2023.3295297",
     "where": "Fig. 9, p. 7",
     "licence": "publisher copyright"
    },
    {
     "id": "msrc_wu2023_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Kirigami catheter passing a 25-degree bifurcation in a leg phantom",
     "source_key": "mohanraj2022_kirigami",
     "source": "Mohanraj et al., 2022 9th IEEE RAS/EMBS International Conference for Biomedical Robotics and Biomechatronics (BioRob) (2022), Fig. 9, p. 6",
     "source_url": "https://doi.org/10.1109/biorob52689.2022.9925350",
     "where": "Fig. 9, p. 6",
     "licence": "publisher copyright"
    },
    {
     "id": "msrc_wu2023_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD of the friction-drive insertion unit with drive wheel and stepper",
     "source_key": "mohanraj2022_kirigami",
     "source": "Mohanraj et al., 2022 9th IEEE RAS/EMBS International Conference for Biomedical Robotics and Biomechatronics (BioRob) (2022), Fig. 5, p. 3",
     "source_url": "https://doi.org/10.1109/biorob52689.2022.9925350",
     "where": "Fig. 5, p. 3",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "wu2023_integrated",
     "doi": "10.1109/lra.2023.3295297",
     "url": null,
     "title": "Integrated Magnetic Location Sensing and Actuation of Steerable Robotic Catheters for Peripheral Arterial Disease Treatment",
     "year": 2023,
     "venue": "IEEE Robotics and Automation Letters"
    },
    {
     "key": "mohanraj2022_kirigami",
     "doi": "10.1109/biorob52689.2022.9925350",
     "url": null,
     "title": "A Kirigami-Based Magnetically Steerable Robotic Catheter for Treatment of Peripheral Artery Disease",
     "year": 2022,
     "venue": "2022 9th IEEE RAS/EMBS International Conference for Biomedical Robotics and Biomechatronics (BioRob)"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (abstract, hardware, results by grep) mohanraj2022_kirigami full (2026-10-14).",
   "notes": "Uniform field, so steering works only in a plane per bifurcation. F4: hardware origin is mohanraj2022 (same coils, catheter, magnets and feeder).",
   "maintainers_own": false,
   "found_by": "actuated-tip"
  },
  {
   "schema_version": 1,
   "id": "mscrddg_tong2025",
   "name": "Soft magnetic rod",
   "full_name": "Magnetic soft continuum robot with real-time DDG hard-magnetic rod simulator and inverse-design field control",
   "group": "Wang, USTC (with M. Liu and W. Huang)",
   "group_short": "USTC",
   "family": "magnetic",
   "category": "magnetic-navigation",
   "first_year": 2025,
   "latest_year": 2025,
   "versions": "arXiv 2503.08864",
   "target_anatomy": "generic confined lumens (vascular and GI), 3D-printed lumen phantom",
   "devices": [
    "other"
   ],
   "devices_driven": "own MSCR: PDMS + NdFeB particles, rod radius 0.6 mm (1.2 mm OD), length 100 mm, magnetised tip 5 mm, E = 3.0 MPa",
   "n_dof": null,
   "n_dof_detail": "Helmholtz coil field (3 axes) + stepper advancer",
   "translation_mechanism": "magnetic",
   "translation_detail": "magnetic (steering) + stepper-motor advancer",
   "rotation_mechanism": "magnetic-field",
   "rotation_detail": "field direction",
   "device_range": "100 mm rod",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "none (contact force estimated in simulation)",
   "haptics_leader": "no",
   "imaging_compat": "camera",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "3D-printed lumen phantoms of varying geometry in Helmholtz coils; counts N.R.",
   "key_numbers": "remanent magnetisation 0.1448 A m; pulse magnetised at about 4 T; contact-force minimisation compared with passive pushing",
   "sim_model": "hard-magnetic elastic rod in discrete differential geometry with reduced-order contact (tong2025_realtime, full)",
   "has_sim_model": true,
   "sim2real": "model-based",
   "sim2real_detail": "model-based: field commands computed from the simulator ran on the hardware (tong2025 Sec. 5); no learned policy",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "render",
    "source": "tong2025_realtime arXiv 2503.08864 Fig. 5 (advancer, MSCR, Helmholtz coils, lumen phantom)",
    "source_url": "https://arxiv.org/abs/2503.08864",
    "licence": "arXiv author preprint, licence not checked",
    "credit": "Tong et al., 2025, Fig. 5. arXiv author preprint, licence not checked.",
    "edits": "native extract (4816 px); 5 labels, Push arrow and 4 leader lines erased (LaMa); background ghosts flattened to the background grey; leader ghosts on the flat-shaded coil face replaced by the column median",
    "file": null
   },
   "pictures": [
    {
     "id": "mscrddg_tong2025_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Rod pushed through a sinusoidal lumen phantom: simulation above, experiment below",
     "source_key": "tong2025_realtime",
     "source": "Tong et al. (2025), Fig. 7, arXiv p. 14",
     "source_url": "https://arxiv.org/abs/2503.08864",
     "where": "Fig. 7, arXiv p. 14",
     "licence": "CC BY-NC-ND 4.0"
    }
   ],
   "sources": [
    {
     "key": "tong2025_realtime",
     "doi": null,
     "url": "https://arxiv.org/abs/2503.08864",
     "title": "Real-time simulation enabled navigation control of magnetic soft continuum robots in confined lumens",
     "year": 2025,
     "venue": null
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (abstract, set-up); speed numbers not extracted",
   "notes": "Best example in this scope of a real-time physics model driving a magnetic wire; not a lone robot.",
   "maintainers_own": false,
   "found_by": "actuated-tip"
  },
  {
   "schema_version": 1,
   "id": "msmsr_li2024",
   "name": "CMNS",
   "full_name": "Multi-section magnetic soft robot with collaborative multirobot navigation system (CMNS)",
   "group": "Xu, University of Macau",
   "group_short": "U. Macau",
   "family": "magnetic",
   "category": "magnetic-navigation",
   "first_year": 2024,
   "latest_year": 2024,
   "versions": "single (Cyborg Bionic Syst. 2024)",
   "target_anatomy": "intravascular phantoms with multiple bifurcations",
   "devices": [
    "other"
   ],
   "devices_driven": "own telescoping two-tube soft robot: Tube-I OD 1.8 / ID 1.2 mm, Tube-II OD 3.5 / ID 2.5 mm",
   "n_dof": null,
   "n_dof_detail": "UR3e carries a 30 mm NdFeB N42 permanent magnet; second manipulator carries ultrasound probe; seven-joint redundancy handled by QP controller",
   "translation_mechanism": "magnetic",
   "translation_detail": "magnetic (steering) + telescoping tube motion",
   "rotation_mechanism": "magnetic-field",
   "rotation_detail": "rotation of external magnet",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "none",
   "haptics_leader": "no",
   "imaging_compat": "ultrasound tracking of the tip, closed loop",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "multi-bifurcation intravascular phantom navigation; counts N.R.",
   "key_numbers": "shape error 3.1-3.9 deg, tip error about 1.0-1.4 mm (Table 2); bending range -125 to 125 deg tested",
   "sim_model": "optimised Cosserat rod model with external heterogeneous field (full)",
   "has_sim_model": true,
   "sim2real": "model-based",
   "sim2real_detail": "model-based control using the Cosserat model on the hardware; no learned policy",
   "picture": {
    "status": "cleared",
    "grade": "A",
    "kind": "photo",
    "source": "li2024_multisection Fig. 1(B) embedded photo (CMNS with two UR arms, magnet, ultrasound probe and phantom; the figure's circles and labels are vector overlays and are not in the raster)",
    "source_url": "https://doi.org/10.34133/cbsystems.0188",
    "licence": "CC BY 4.0 (Cyborg Bionic Syst.; PMC open-access metadata licence_code CC BY)",
    "credit": "Li et al., Cyborg and Bionic Systems (2024), Fig. 1. CC BY 4.0 (Cyborg Bionic Syst.; PMC open-access metadata licence_code CC BY).",
    "edits": "native extract from the PMC open-data PDF; no crop, no edits; not upscaled",
    "file": "pictures/msmsr_li2024.jpg"
   },
   "pictures": [
    {
     "id": "msmsr_li2024_01",
     "status": "cleared",
     "file": "pictures/extra/msmsr_li2024_01.jpg",
     "thumb": "pictures/thumbs/msmsr_li2024_01.jpg",
     "kind": "in-use",
     "caption": "Two UR arms with magnet and ultrasound transducer over a soft anthropomorphic phantom",
     "source_key": "li2024_multisection",
     "source": "Li et al., Cyborg and Bionic Systems (2024), Fig. 8(A), p. 11",
     "source_url": "https://doi.org/10.34133/cbsystems.0188",
     "where": "Fig. 8(A), p. 11",
     "licence": "CC BY 4.0"
    },
    {
     "id": "msmsr_li2024_02",
     "status": "cleared",
     "file": "pictures/extra/msmsr_li2024_02.jpg",
     "thumb": "pictures/thumbs/msmsr_li2024_02.jpg",
     "kind": "in-use",
     "caption": "Autonomous navigation through a 3D ring path: setup and snapshot sequence",
     "source_key": "li2024_multisection",
     "source": "Li et al., Cyborg and Bionic Systems (2024), Fig. 7, p. 11",
     "source_url": "https://doi.org/10.34133/cbsystems.0188",
     "where": "Fig. 7, p. 11",
     "licence": "CC BY 4.0"
    },
    {
     "id": "msmsr_li2024_03",
     "status": "cleared",
     "file": "pictures/extra/msmsr_li2024_03.jpg",
     "thumb": "pictures/thumbs/msmsr_li2024_03.jpg",
     "kind": "render",
     "caption": "Collaborative multirobot navigation system: arm kinematics, whole system, US tracking",
     "source_key": "li2024_multisection",
     "source": "Li et al., Cyborg and Bionic Systems (2024), Fig. 4, p. 7",
     "source_url": "https://doi.org/10.34133/cbsystems.0188",
     "where": "Fig. 4, p. 7",
     "licence": "CC BY 4.0"
    }
   ],
   "sources": [
    {
     "key": "li2024_multisection",
     "doi": "10.34133/cbsystems.0188",
     "url": null,
     "title": "Multi-Section Magnetic Soft Robot with Multirobot Navigation System for Vasculature Intervention",
     "year": 2024,
     "venue": "Cyborg and Bionic Systems"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full text from (no PDF)",
   "notes": "Picture can be cropped from the CC BY PDF once downloaded.",
   "maintainers_own": false,
   "found_by": "actuated-tip"
  },
  {
   "schema_version": 1,
   "id": "magflow_pancaldi2025",
   "name": "MagFlow",
   "full_name": "MagFlow flow-driven magnetic microcatheter + OmniMag steering platform",
   "group": "Sakar, EPFL (with Mosimann, Toronto Western Hospital)",
   "group_short": "EPFL",
   "family": "magnetic",
   "category": "magnetic-navigation",
   "first_year": 2025,
   "latest_year": 2025,
   "versions": "arXiv 2508.05312",
   "target_anatomy": "distal cerebral / spinal arteries, porcine model",
   "devices": [
    "microcatheter",
    "catheter"
   ],
   "devices_driven": "inflatable flat-tube microcatheter, head width 150-250 um; fed through a 2.7 Fr (0.7 mm lumen) delivery microcatheter inside a 5 Fr guide catheter",
   "n_dof": null,
   "n_dof_detail": "OmniMag: spherical rotor with permanent magnet oriented by three orthogonal coils, mounted on a collaborative robot arm",
   "translation_mechanism": "other",
   "translation_detail": "other: blood-flow carried; no pushed shaft",
   "rotation_mechanism": "magnetic-field",
   "rotation_detail": "field direction",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "none",
   "haptics_leader": "no",
   "imaging_compat": "bi-plane fluoroscopy compatible",
   "sterility": "N.R.",
   "highest_validation": "animal",
   "validation_detail": "porcine in vivo under X-ray; six branches repeatedly steered in vertebral region; navigated 180 um arteries and a 500 um hairpin with 0.69 mm radius; superselective contrast and embolic infusion",
   "key_numbers": "OmniMag 3.7 mT at 2 A, 1.7 N m torque on the magnet; average field during steering 5.7 +/- 1.4 mT; arteries as small as 180 um; min curvature radius 0.69 mm",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "A",
    "kind": "photo",
    "source": "EPFL news \"Microcatheter delivers therapies to the tiniest blood vessels\" (actu.epfl.ch/news/microcatheter-delivers-therapies-to-the-tiniest-bl), image 158504 original 7678x5121 (OmniMag on a UR arm over the light pad, stylus, pump)",
    "source_url": null,
    "licence": "CC BY-SA 4.0 (EPFL/Alain Herzog)",
    "credit": "EPFL news \"Microcatheter delivers therapies to the tiniest blood vessels\" (actu.epfl.ch/news/microcatheter-delivers-therapies-to-the-tiniest-bl), image 158504 original 7678x5121 (OmniMag on a UR arm over the light pad, stylus, pump). Licence: CC BY-SA 4.0 (EPFL/Alain Herzog).",
    "edits": "crop removing the operators faces, downscaled 50 %",
    "file": null
   },
   "pictures": [
    {
     "id": "magflow_pancaldi2025_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "MagFlow steered by OmniMag above a planar phantom, guided with a stylus",
     "source_key": "pancaldi2025_flowdriven",
     "source": "Pancaldi et al. (2025), EPFL news image 158506",
     "source_url": "https://arxiv.org/abs/2508.05312",
     "where": "EPFL news image 158506, https://actu.epfl.ch/image/158506/original/7713x5145.jpg",
     "licence": "CC BY-SA 4.0 (EPFL / Alain Herzog)"
    },
    {
     "id": "magflow_pancaldi2025_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "OmniMag coil head over the microfluidic chip phantom carrying the microcatheter",
     "source_key": "pancaldi2025_flowdriven",
     "source": "Pancaldi et al. (2025), EPFL news image 158507",
     "source_url": "https://arxiv.org/abs/2508.05312",
     "where": "EPFL news image 158507, https://actu.epfl.ch/image/158507/original/8192x5464.jpg",
     "licence": "CC BY-SA 4.0 (EPFL / Alain Herzog)"
    },
    {
     "id": "magflow_pancaldi2025_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Rendering of OmniMag: rotating-magnet coil head on a collaborative arm",
     "source_key": "pancaldi2025_flowdriven",
     "source": "Pancaldi et al. (2025), Fig. 2(a), arXiv p. 21",
     "source_url": "https://arxiv.org/abs/2508.05312",
     "where": "Fig. 2(a), arXiv p. 21",
     "licence": "CC BY-NC-ND 4.0"
    },
    {
     "id": "magflow_pancaldi2025_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "OmniMag coil head 10 cm above the planar phantom",
     "source_key": "pancaldi2025_flowdriven",
     "source": "Pancaldi et al. (2025), Fig. 2(c), arXiv p. 21",
     "source_url": "https://arxiv.org/abs/2508.05312",
     "where": "Fig. 2(c), arXiv p. 21",
     "licence": "CC BY-NC-ND 4.0"
    },
    {
     "id": "magflow_pancaldi2025_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "MagFlow tip choosing branches in a planar phantom under steered fields",
     "source_key": "pancaldi2025_flowdriven",
     "source": "Pancaldi et al. (2025), Fig. 2(d), arXiv p. 21",
     "source_url": "https://arxiv.org/abs/2508.05312",
     "where": "Fig. 2(d), arXiv p. 21",
     "licence": "CC BY-NC-ND 4.0"
    },
    {
     "id": "magflow_pancaldi2025_06",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Drawing of the MagFlow microcatheter: hub, reinforced tube, microfabricated tube, head",
     "source_key": "pancaldi2025_flowdriven",
     "source": "Pancaldi et al. (2025), Fig. 1(a-b), arXiv p. 19",
     "source_url": "https://arxiv.org/abs/2508.05312",
     "where": "Fig. 1(a-b), arXiv p. 19",
     "licence": "CC BY-NC-ND 4.0"
    }
   ],
   "sources": [
    {
     "key": "pancaldi2025_flowdriven",
     "doi": null,
     "url": "https://arxiv.org/abs/2508.05312",
     "title": "Flow-driven magnetic microcatheter for superselective arterial embolization",
     "year": 2025,
     "venue": null
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (abstract, platform and in vivo sections)",
   "notes": "Smallest device in my scope; there is no bedside push drive.",
   "maintainers_own": false,
   "found_by": "actuated-tip"
  },
  {
   "schema_version": 1,
   "id": "millispinner_wu2024",
   "name": "Milli-spinner",
   "full_name": "Magnetic milli-spinner (untethered)",
   "group": "Zhao, Stanford Mechanical Engineering",
   "group_short": "Stanford",
   "family": "magnetic",
   "category": "magnetic-navigation",
   "first_year": 2024,
   "latest_year": 2026,
   "versions": "arXiv 2410.21112; optimisation follow-up Adv. Robotics Res. 2026 (arXiv 2601.01319, abstract not read)",
   "target_anatomy": "cerebral and general vasculature; phantoms, porcine blood aneurysm model",
   "devices": [
    "other"
   ],
   "devices_driven": "untethered 2.5 mm OD hollow spinner with helical fins and slits, in 3.5 mm ID tubes",
   "n_dof": null,
   "n_dof_detail": "rotating magnetic field from Helmholtz coils; six-axis robot arm holding a permanent magnet for navigation",
   "translation_mechanism": "magnetic",
   "translation_detail": "magnetic",
   "rotation_mechanism": "magnetic-field",
   "rotation_detail": "spinning in rotating field (up to 8.4k rpm tested)",
   "device_range": "untethered",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "none",
   "haptics_leader": "no",
   "imaging_compat": "fluoroscopy-guided in phantom",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "vascular phantoms; in-situ embolisation of an aneurysm model filled with anticoagulated porcine blood; no animal",
   "key_numbers": "23 cm/s in tubular environment (abstract); stable spinning needs 15-20 mT; 56.4 cm/s predicted by CFD at 9.6k rpm",
   "sim_model": "CFD of swimming speed compared with experiment (wu2024_millispinner, full)",
   "has_sim_model": true,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "A",
    "kind": "photo",
    "source": "Stanford Robotics Center demo page (src.stanford.edu/demo/magnetic-milli-spinner-for-robotic-endovascular-surgery-launch), image \"magnetic millispinner (2).jpg\" at 2500w (UR arm with rotating magnet over the head phantom)",
    "source_url": null,
    "licence": "web image (Stanford Robotics Center), terms not stated",
    "credit": "Stanford Robotics Center demo page (src.stanford.edu/demo/magnetic-milli-spinner-for-robotic-endovascular-surgery-launch), image \"magnetic millispinner (2).jpg\" at 2500w (UR arm with rotating magnet over the head phantom). Licence: web image (Stanford Robotics Center), terms not stated.",
    "edits": "WebP converted to PNG; no crop, no edits; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "millispinner_wu2024_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Robot arm with rotating magnet beside the head phantom on a light table",
     "source_key": "wu2024_millispinner",
     "source": "Wu et al. (2024), Stanford Robotics Center demo page image 'magnetic millispinner (1).jpg', src.stanford.edu/demo/magnetic-milli-spinner-for-robotic-endovascular-surgery-launch",
     "source_url": "https://arxiv.org/abs/2410.21112",
     "where": "Stanford Robotics Center demo page image 'magnetic millispinner (1).jpg', src.stanford.edu/demo/magnetic-milli-spinner-for-robotic-endovascular-surgery-launch",
     "licence": "press image (Stanford Robotics Center demo page)"
    },
    {
     "id": "millispinner_wu2024_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Rotating magnet close to the transparent head phantom with cerebral arteries",
     "source_key": "wu2024_millispinner",
     "source": "Wu et al. (2024), Stanford Robotics Center demo page image 'Magnetic Milli-spinner.png'",
     "source_url": "https://arxiv.org/abs/2410.21112",
     "where": "Stanford Robotics Center demo page image 'Magnetic Milli-spinner.png'",
     "licence": "press image (Stanford Robotics Center demo page)"
    },
    {
     "id": "millispinner_wu2024_03",
     "status": "cleared",
     "file": "pictures/extra/millispinner_wu2024_03.jpg",
     "thumb": "pictures/thumbs/millispinner_wu2024_03.jpg",
     "kind": "in-use",
     "caption": "Rotating magnet on a robot arm driving the spinner through a head-model flow phantom",
     "source_key": "wu2025_millispinner",
     "source": "Wu et al., Advanced Materials (2025), Fig. 2(h-j), p. 3",
     "source_url": "https://doi.org/10.1002/adma.202508180",
     "where": "Fig. 2(h-j), p. 3",
     "licence": "CC BY (Creative Commons Attribution License)"
    },
    {
     "id": "millispinner_wu2024_04",
     "status": "cleared",
     "file": "pictures/extra/millispinner_wu2024_04.jpg",
     "thumb": "pictures/thumbs/millispinner_wu2024_04.jpg",
     "kind": "in-use",
     "caption": "Fluoroscopy-guided navigation setup in an angiography suite with the flow model",
     "source_key": "wu2025_millispinner",
     "source": "Wu et al., Advanced Materials (2025), Fig. 2(e-f), p. 3",
     "source_url": "https://doi.org/10.1002/adma.202508180",
     "where": "Fig. 2(e-f), p. 3",
     "licence": "CC BY (Creative Commons Attribution License)"
    },
    {
     "id": "millispinner_wu2024_05",
     "status": "cleared",
     "file": "pictures/extra/millispinner_wu2024_05.jpg",
     "thumb": "pictures/thumbs/millispinner_wu2024_05.jpg",
     "kind": "close-up",
     "caption": "Optimized milli-spinner design drawing with photos of the printed spinner",
     "source_key": "lu2026_millispinner",
     "source": "Lu et al., Advanced Robotics Research (2026), Fig. 8(a), p. 9",
     "source_url": "https://doi.org/10.1002/adrr.70121",
     "where": "Fig. 8(a), p. 9",
     "licence": "CC BY (Creative Commons Attribution License)"
    }
   ],
   "sources": [
    {
     "key": "wu2024_millispinner",
     "doi": null,
     "url": "https://arxiv.org/abs/2410.21112",
     "title": "Magnetic Milli-spinner for Robotic Endovascular Surgery",
     "year": 2024,
     "venue": null
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (abstract and results by grep)",
   "notes": "Untethered: no bedside drive and no tip actuation, kept as a magnetic-navigation comparison point.",
   "maintainers_own": false,
   "found_by": "actuated-tip"
  },
  {
   "schema_version": 1,
   "id": "mricath_hao2025",
   "name": "MRI-actuated cath.",
   "full_name": "MRI-actuated robotic catheter (Lorentz-force micro-coils)",
   "group": "Cavusoglu, Case Western Reserve University",
   "group_short": "Case Western",
   "family": "magnetic",
   "category": "magnetic-navigation",
   "first_year": null,
   "latest_year": 2025,
   "versions": "single-coil-set prototype in 2025 kinematics paper; earlier design papers cited (refs 5-7 of hao2025, not read)",
   "target_anatomy": "cardiac EP (atrial fibrillation ablation under real-time MRI)",
   "devices": [
    "catheter"
   ],
   "devices_driven": "own catheter: rigid actuator segment with one axial and two side coils between flexible segments",
   "n_dof": null,
   "n_dof_detail": "3 coil currents per actuator (one coil set in the prototype)",
   "translation_mechanism": "magnetic",
   "translation_detail": "magnetic (MRI scanner static field acts on current-carrying coils); insertion length is an input",
   "rotation_mechanism": "magnetic-field",
   "rotation_detail": "coil torque",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "none",
   "haptics_leader": "no",
   "imaging_compat": "MRI-actuated and MR-guided by design; catadioptric stereo camera used in bench tests",
   "sterility": "N.R.",
   "highest_validation": "bench",
   "validation_detail": "open-loop complex tip trajectories tracked by stereo camera; no phantom with flow",
   "key_numbers": "N.R. (error figures not extracted)",
   "sim_model": "static Cosserat rod with analytical Jacobians, real-time (hao2025_realtime, abstract + method)",
   "has_sim_model": true,
   "sim2real": "model-based",
   "sim2real_detail": "model-based: kinematic model used for open-loop control of the prototype; no learned policy",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "photo",
    "source": "hao2025_realtime arXiv 2512.23085 Fig. 1 (one-coil-set catheter prototype hanging from its base)",
    "source_url": "https://arxiv.org/abs/2512.23085",
    "licence": "arXiv author preprint, licence not checked",
    "credit": "Hao et al., 2025, Fig. 1. arXiv author preprint, licence not checked.",
    "edits": "native extract; crop to the catheter column (drops the coil-drawing inset); 7 arrowheads on the plain wall erased (LaMa); not upscaled",
    "file": null
   },
   "pictures": [],
   "sources": [
    {
     "key": "hao2025_realtime",
     "doi": null,
     "url": "https://arxiv.org/abs/2512.23085",
     "title": "Real-Time Forward Kinematics and Jacobians for Control of an MRI-Guided Magnetically Actuated Robotic Catheter",
     "year": 2025,
     "venue": null
    }
   ],
   "read_level": "abstract",
   "read_level_detail": "abstract and intro read; numbers not extracted",
   "notes": "Cardiac EP, no mechanical bedside push described in what I read.",
   "maintainers_own": false,
   "found_by": "actuated-tip"
  },
  {
   "schema_version": 1,
   "id": "cobot_kim2026",
   "name": "Cobot guidewire",
   "full_name": "Intravascular collaborative robotic (Cobot) magnetic guidewire",
   "group": "DGIST (Daegu Gyeongbuk Institute of Science and Technology) and its spin-off IMsystem, with UMass Amherst, EPFL and Kyungpook National University (kim2026_magnetic affiliations, read by P6 from PMC13410658); 2022 ECMIS: DGIST (Hongsoo Choi, PI), Hanyang University ERICA (Byung-Ju Yi, advancer), Seoul National University Bundang Hospital, Seoul St. Mary's Hospital and ETH Zurich (hwang2022_ecmis p. 1, 14)",
   "group_short": "DGIST",
   "family": "magnetic",
   "category": "magnetic-navigation",
   "first_year": 2022,
   "latest_year": 2026,
   "versions": "2022 ECMIS (hwang2022_ecmis, Adv. Healthc. Mater.): eight-coil hemispherical electromagnetic actuation system under a carbon-composite bed, biplane C-arms, magnetic tip on a 0.014-in wire, Hanyang 5-DOF master-slave advancer, 2 swine -> 2026 Cobot guidewire (kim2026_magnetic): 8-coil system with IMsystem, phantom and swine. The link is inferred from the shared DGIST / IMsystem authors (S. Jeon, J.-y. Kim) and the eight-coil design; ECMIS is not named 'Cobot'; 2018-19: DGIST (S. Jeon, H. Choi) magnetic soft guidewire tip steered in MiniMag (Jeon 2018 Micro Nano Syst. Lett.) and OctoMag (Jeon 2019 Soft Robot.), phantoms (Hwang 2020 Figs. 7a-b; Konda 2025 Table 2 row 3) (hwang2020_review; konda2025_robotically)",
   "target_anatomy": "neuro (2026, phantom and swine); coronary, iliac and renal arteries (2022 ECMIS, swine)",
   "devices": [
    "guidewire",
    "catheter"
   ],
   "devices_driven": "2026: guidewire with permanent magnet and magnetic polymer tip, tip OD 0.4 mm (kim2026_magnetic, per P6 notes); 2022: 400 um x 10 mm tip unit (3 mm NdFeB magnet + magnetic polymer in a silicone tube) on a 0.014-in Fielder FC guidewire; the advancer moves the guidewire and a 6 F guiding catheter (hwang2022_ecmis p. 4, 8, 12)",
   "n_dof": null,
   "n_dof_detail": "2022: coil system gives 5-DOF magnetic control (3 translation, 2 rotation); advancer = Hanyang 5-DOF slave robot used for insertion and retraction (hwang2022_ecmis p. 8); 2026 N.R.",
   "translation_mechanism": "magnetic",
   "translation_detail": "magnetic (steering); 2022 insertion by the motorised master-slave advancer (hwang2022_ecmis p. 8)",
   "rotation_mechanism": "magnetic-field",
   "rotation_detail": "field direction",
   "device_range": "2022: tip steers over 90 degrees at 5-15 mT (hwang2022_ecmis p. 4)",
   "footprint_mm": "2022 coil workspace about 15 x 15 x 15 cm3 at up to 15 mT (hwang2022_ecmis p. 8); 2026: 150 mm cube of open volume with a uniform-field 52 mm cube, 30 mT used (kim2026_magnetic, per P6 notes)",
   "mass_kg": "N.R.",
   "force_sensing": "N.R.",
   "haptics_leader": "2022: C++/Qt GUI from a shielded control booth, haptics N.R. (hwang2022_ecmis p. 8)",
   "imaging_compat": "2022: biplane C-arms (floor and ceiling) with flat-panel detectors; the X-ray beam passes a central hole in the coil array; no electromagnetic interference observed (hwang2022_ecmis p. 8, 12)",
   "sterility": "N.R.",
   "highest_validation": "animal",
   "validation_detail": "2026: phantom (n = 7) and swine (n = 11) procedures vs a manual wire (kim2026_magnetic, per P6 notes); 2022: 2D phantom on OctoMag (4 repeats), 3D silicone phantom (3 repeats), 2 crossbred pigs (about 30 kg): iliac, circumflex and LAD with an artificial occlusion in swine 1, renal in swine 2; access by hand, then teleoperated by engineers (hwang2022_ecmis p. 6-13)",
   "key_numbers": "2026: procedure time 49.57 +- 19.61 vs 103.29 +- 68.18 s manual in phantom (p = 0.085), 22.36 +- 7.09 vs 79.63 +- 49.07 s in swine (p = 0.0033) (kim2026_magnetic, per P6 notes); 2022: friction coefficient 10.68 -> 0.09; 3D phantom right-coronary target 26 +- 4.04 s; operator dose rate in the booth < 11 uSv/h (hwang2022_ecmis)",
   "sim_model": "2022: analytical Euler-Bernoulli tip model solved by Newton-Raphson (hwang2022_ecmis p. 13); no simulator",
   "has_sim_model": true,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "render",
    "source": "https://imsystem.kr/images/pathfinder_navi.jpg (alt \"Pathfinder_Navi product image\"), page https://imsystem.kr/products#pathfinder",
    "source_url": "https://imsystem.kr/images/pathfinder_navi.jpg",
    "licence": "press image",
    "credit": "https://imsystem.kr/images/pathfinder_navi.jpg (alt \"Pathfinder_Navi product image\"), page https://imsystem.kr/products#pathfinder. Licence: press image.",
    "edits": "palette PNG with transparency composited on white; cropped with 4 % margin",
    "file": null
   },
   "pictures": [
    {
     "id": "cobot_kim2026_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Electromagnetic coil unit (IM_SUPERMAG_CLINIC) with its ring of coil cores",
     "source_key": "imsystem2026_pathfinder-navi_BROCHURE",
     "source": "imsystem2026_pathfinder-navi_BROCHURE, brochure p. 2, \"Electromagnetic coils\" panel (also",
     "source_url": "https://imsystem.kr/products",
     "where": "brochure p. 2, \"Electromagnetic coils\" panel (also https://imsystem.kr/products)",
     "licence": "press image"
    },
    {
     "id": "cobot_kim2026_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Coil unit placed under the patient table of a C-arm room (illustration)",
     "source_key": "https://imsystem.kr/images/pathfinder_overview_v2_en.png",
     "source": "https://imsystem.kr/images/pathfinder_overview_v2_en.png, products page, \"Surgical room & coils under the bed\" panel",
     "source_url": null,
     "where": "products page, \"Surgical room & coils under the bed\" panel",
     "licence": "press image"
    },
    {
     "id": "cobot_kim2026_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Remote control station outside the X-ray room (illustration)",
     "source_key": "imsystem2026_pathfinder-navi_BROCHURE",
     "source": "imsystem2026_pathfinder-navi_BROCHURE, brochure p. 2, \"Remote control\" panel",
     "source_url": null,
     "where": "brochure p. 2, \"Remote control\" panel",
     "licence": "press image"
    },
    {
     "id": "cobot_kim2026_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Coil system in a catheterisation laboratory",
     "source_key": "web:imsystem.kr",
     "source": "imsystem.kr, company page (P6 ctx picture)",
     "source_url": null,
     "where": "company page (P6 ctx picture)",
     "licence": "press image"
    },
    {
     "id": "cobot_kim2026_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "ECMIS (2022, same DGIST group): biplane C-arms, coils under the bed, advancer, shielded booth",
     "source_key": "hwang2022_ecmis",
     "source": "Hwang et al., Advanced Healthcare Materials (2022), Fig. 1(D), p. 3",
     "source_url": "https://doi.org/10.1002/adhm.202102529",
     "where": "Fig. 1(D), p. 3",
     "licence": "publisher copyright"
    },
    {
     "id": "cobot_kim2026_06",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "ECMIS (2022): eight-coil electromagnetic actuation system integrated under the surgical bed",
     "source_key": "hwang2022_ecmis",
     "source": "Hwang et al., Advanced Healthcare Materials (2022), Fig. 4(A), p. 9",
     "source_url": "https://doi.org/10.1002/adhm.202102529",
     "where": "Fig. 4(A), p. 9",
     "licence": "publisher copyright"
    },
    {
     "id": "cobot_kim2026_07",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "ECMIS (2022) in vivo set-up: swine on the bed, advancer, ceiling C-arm, control booth",
     "source_key": "hwang2022_ecmis",
     "source": "Hwang et al., Advanced Healthcare Materials (2022), Fig. 5(A), p. 10",
     "source_url": "https://doi.org/10.1002/adhm.202102529",
     "where": "Fig. 5(A), p. 10",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "kim2026_magnetic",
     "doi": "10.1002/adhm.71365",
     "url": null,
     "title": "Magnetic Control of Intravascular Collaborative Robotic (Cobot) Guidewire: Neurovascular Intervention Studies in Phantom and Swine Models",
     "year": 2026,
     "venue": "Advanced Healthcare Materials"
    },
    {
     "key": "hwang2022_ecmis",
     "doi": "10.1002/adhm.202102529",
     "url": null,
     "title": "An Electromagnetically Controllable Microrobotic Interventional System for Targeted, Real-Time Cardiovascular Intervention",
     "year": 2022,
     "venue": "Advanced Healthcare Materials"
    },
    {
     "key": "hwang2020_review",
     "doi": "10.1007/s11370-020-00311-0",
     "url": null,
     "title": "A review of magnetic actuation systems and magnetically actuated guidewire- and catheter-based microrobots for vascular interventions",
     "year": 2020,
     "venue": "Intelligent Service Robotics"
    },
    {
     "key": "konda2025_robotically",
     "doi": "10.1126/scirobotics.adt7461",
     "url": null,
     "title": "Robotically steerable guidewires—Current trends and future directions",
     "year": 2025,
     "venue": "Science Robotics"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (hwang2022_ecmis); kim2026_magnetic full HTML via P6 notes (not re-read by X2)",
   "notes": "Group and 2026 numbers from P6_gallery.md section 4 (PMC13410658 full HTML). ECMIS (2022) added as the predecessor system by inference; first_year 2026 -> 2022 rests on that inference. | X2 2026-11-08. | X4 2026-11-08: first_year marked (inferred): ECMIS (hwang2022_ecmis) taken as the predecessor from shared authors and the 8-coil design; no text states the link",
   "maintainers_own": false,
   "found_by": "actuated-tip"
  },
  {
   "schema_version": 1,
   "id": "microvast_tognarelli2012",
   "name": "MicroVAST",
   "full_name": "MicroVAST robotic magnetic navigation platform (external permanent magnet on a robot arm, robotic ultrasound tracking)",
   "group": "Menciassi, The BioRobotics Institute, Scuola Superiore Sant'Anna",
   "group_short": "SSSA",
   "family": "magnetic",
   "category": "magnetic-navigation",
   "first_year": 2012,
   "latest_year": 2016,
   "versions": "2012: wireless magnetic capsule dragged by an EPM on a 6-DoF arm, second arm holds the US probe (tognarelli2012_magnetic); 2015: 2D US tracking of soft-tethered devices on the MicroVAST platform (mura2015_ultrasound, abstract); 2016: 3D US tracking of a magnetic-dragged soft-tethered device (mura2016_computer, abstract)",
   "target_anatomy": "cardiovascular (atherosclerotic arteries, tognarelli2012_magnetic Introduction); listed as neuroendovascular in alekseeva2025_design Table 14",
   "devices": [
    "other"
   ],
   "devices_driven": "2012: capsule 5 mm x 10.6 mm, 0.75 g, with an internal NdFeB N52 magnet of 6 tablets (3.2 mm x 1.6 mm) (tognarelli2012_magnetic Methods); 2015-16: soft-tethered endovascular device (dimensions N.R. in the abstracts)",
   "n_dof": 6,
   "n_dof_detail": "6 (alekseeva2025_design Table 14): Mitsubishi RV-3SB 6-DoF arm moves the EPM; RV-6SL 6-DoF arm moves the US probe (tognarelli2012_magnetic Methods)",
   "translation_mechanism": "magnetic",
   "translation_detail": "magnetic (dragging by the moving external permanent magnet)",
   "rotation_mechanism": "other",
   "rotation_detail": "EPM pose (robot arm)",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R. (EPM 0.4 kg, 51 mm diameter x 25 mm, tognarelli2012_magnetic Methods)",
   "force_sensing": "none",
   "haptics_leader": "Phantom Omni haptic input device moves the EPM arm (tognarelli2012_magnetic Methods)",
   "imaging_compat": "ultrasound: Esaote CA430E convex probe (3.5-5 MHz) on the second arm with real-time US servoing (tognarelli2012_magnetic); 3D US tracking (mura2016_computer)",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "soft-tethered device: tracking and locomotion tests on the platform (mura2016_computer abstract; phantom type N.R.; alekseeva2025_design: 'ex vivo phantom studies (TRL3)'). The 2012 tests used the untethered capsule: 300 mm path of Plexiglas tube, PVC tube and a freshly excised porcine vessel in a flow loop at 2.3, 3.1 and 3.7 L/min, with and against flow (tognarelli2012_magnetic Methods)",
   "key_numbers": "EPM NdFeB N52, remanence 1.48 T; arm drag speed 5 mm/s (tognarelli2012_magnetic Methods); 3D US tracking error 6.4 +/- 2.8 px, mean displacement from the pre-operative path 13.6 +/- 4.5 mm, 12.2 +/- 1.5 ms per frame (mura2016_computer abstract)",
   "sim_model": "none found (analytical magnetic and fluid-drag model, tognarelli2012_magnetic)",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "photo",
    "source": "tognarelli2012_magnetic Fig. 2",
    "source_url": "https://doi.org/10.1007/s11701-011-0332-1",
    "licence": "publisher copyright",
    "credit": "Tognarelli et al., Journal of Robotic Surgery (2011), Fig. 2. publisher copyright.",
    "edits": "native extract from tognarelli2012_magnetic-propulsion_JRS.pdf p. 3; no crop; none upscaled",
    "file": null
   },
   "pictures": [],
   "sources": [
    {
     "key": "tognarelli2012_magnetic",
     "doi": "10.1007/s11701-011-0332-1",
     "url": null,
     "title": "Magnetic propulsion and ultrasound tracking of endovascular devices",
     "year": 2011,
     "venue": "Journal of Robotic Surgery"
    },
    {
     "key": "mura2015_ultrasound",
     "doi": "10.1002/rcs.1603",
     "url": null,
     "title": "Ultrasound-based tracking strategy for endoluminal devices in cardiovascular surgery: Computer-assisted robotic strategy for autonomous intervention",
     "year": 2014,
     "venue": "The International Journal of Medical Robotics and Computer Assisted Surgery"
    },
    {
     "key": "mura2016_computer",
     "doi": "10.1080/24699322.2016.1185467",
     "url": null,
     "title": "A computer-assisted robotic platform for vascular procedures exploiting 3D US-based tracking",
     "year": 2016,
     "venue": "Computer Assisted Surgery"
    },
    {
     "key": "alekseeva2025_design",
     "doi": "10.1002/rob.22480",
     "url": null,
     "title": "The Design of Endovascular Robots for Cardiac Interventions: A Survey",
     "year": 2024,
     "venue": "Journal of Field Robotics"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (tognarelli2012_magnetic); abstract (mura2015_ultrasound, mura2016_computer)",
   "notes": "Family: magnetic. The catheter-like device (soft-tethered) appears only in the 2015-16 papers, read as abstracts; Mura 2016 (T&F, CC BY-NC) and Mura 2015 (Wiley) are on the manual-download list and would decide the device size and test level. alekseeva2025_design Sec. 4 calls the field source an electromagnet; tognarelli2012_magnetic uses a permanent magnet.",
   "maintainers_own": false,
   "found_by": "actuated-tip"
  },
  {
   "schema_version": 1,
   "id": "belharet_elfakir2022",
   "name": "PRISME platforms",
   "full_name": "Magnetic catheter navigation platforms of the Belharet lab (8-coil EMA with haptic and VR teleoperation; KUKA-held permanent magnet with motorized catheter driver)",
   "group": "Belharet, PRISME EA 4229, Junia HEI / Univ. Orleans",
   "group_short": "U. Orléans",
   "family": "magnetic",
   "category": "magnetic-navigation",
   "first_year": 2022,
   "latest_year": 2024,
   "versions": "VHMM: 8-electromagnet EMA of the lab + PI XYZ positioner pushing the catheter + Omega.6 haptic master + Simscape VR (elfakir2022_towards, AIM 2022); KUKA LBR iiwa R14 holding a 70 x 70 mm NdFeB magnet + motorized catheter driver + glass phantom (elfakir2022_magnetic, ICARM 2022); PhD thesis 2024 (HAL tel-04914777, not opened)",
   "target_anatomy": "complex vascular networks and small arteries (2 mm), applications named: brain tumours, stenosis, cardiac ablation, renal artery occlusion (elfakir2022_magnetic Sec. I, Fig. 1)",
   "devices": [
    "catheter"
   ],
   "devices_driven": "own magnetic catheters: LDPE shaft with 3 NdFeB magnets (1 mm x 3 mm) at the tip (elfakir2022_towards Sec. II-B); 1 mm catheter with 3 magnets (1 x 3 mm, 8 mm spacing) in LDPE tube (elfakir2022_magnetic Table I, Fig. 6B)",
   "n_dof": null,
   "n_dof_detail": "EMA version: 2 bending angles + 1 insertion from the haptic device (elfakir2022_towards Sec. V); arm version: 7-DoF arm + motorized insertion (elfakir2022_magnetic Sec. IV-C)",
   "translation_mechanism": "magnetic",
   "translation_detail": "magnetic (tip steering); linear-stage push of the proximal end (PI XYZ stage, elfakir2022_towards Sec. II-A; motorized catheter control system, elfakir2022_magnetic Sec. IV-C)",
   "rotation_mechanism": "other",
   "rotation_detail": "field of 8 fixed electromagnets (EMA) or pose of a permanent magnet on a 7-DoF arm (KUKA)",
   "device_range": "catheter OD 1 mm (elfakir2022_magnetic Sec. IV-A)",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "none on the catheter; haptic forces come from virtual contact in the VR model (Ks = 1000 N/m, bm = 30 Ns/m, elfakir2022_towards Sec. III-D)",
   "haptics_leader": "Omega.6 (Force Dimension) with force feedback from simulated contacts (elfakir2022_towards Sec. II-A, III-D)",
   "imaging_compat": "cameras only (stereo vision; CCD camera tracking)",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "glass phantom with 2 mm arteries, 20 cm path and four successive bifurcations (45 and 90 deg): three navigations, all reached the target (elfakir2022_magnetic Sec. IV-C, Fig. 8); free-space and glass-vessel deflection under the EMA (elfakir2022_towards Figs. 6-8)",
   "key_numbers": "max tip deflection 155 deg (elfakir2022_magnetic Sec. IV-B); first navigation 35 s including actuator moves (Sec. IV-C); EMA current-to-angle polynomial model of degree 2 with error 0.39 (elfakir2022_towards Sec. IV-A); magnet 70 x 70 mm, Br 1.42 T (elfakir2022_magnetic Sec. II)",
   "sim_model": "Simscape (MATLAB) multibody model of the catheter with a spatial contact-force model, run alongside the real catheter as VR (elfakir2022_towards Sec. III); Euler-Bernoulli multi-element deflection model for catheter design (elfakir2022_magnetic Sec. II)",
   "has_sim_model": true,
   "sim2real": "none-found",
   "sim2real_detail": "none found (the virtual model drives haptic feedback while the real catheter runs open loop; no simulation-trained controller, elfakir2022_towards Sec. IV)",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "photo",
    "source": "elfakir2022_towards (AIM 2022, ) Fig. 2 (block diagram of the master-slave robotic system, p. 2): the photo of the 8-electromagnet actuation platform embedded in that figure, printed 34 x 56 pt but stored at 1141 x 1831 px",
    "source_url": "https://doi.org/10.1109/aim52237.2022.9863252",
    "licence": "publisher copyright (IEEE)",
    "credit": "Elfakir et al., 2022 IEEE/ASME International Conference on Advanced Intelligent Mechatronics (AIM) (2022), Fig. 2. publisher copyright (IEEE).",
    "edits": "native extract (1141x1831); no crop; no erasing; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "belharet_elfakir2022_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Haptic master, VR screen and eight-coil electromagnetic actuation system",
     "source_key": "elfakir2022_towards",
     "source": "Elfakir et al., 2022 IEEE/ASME International Conference on Advanced Intelligent Mechatronics (AIM) (2022), Fig. 1, p. 1",
     "source_url": "https://doi.org/10.1109/aim52237.2022.9863252",
     "where": "Fig. 1, p. 1",
     "licence": "publisher copyright"
    },
    {
     "id": "belharet_elfakir2022_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Prototype 1 mm magnetic catheter with three magnets on a ruler",
     "source_key": "elfakir2022_magnetic",
     "source": "Elfakir et al., 2022 International Conference on Advanced Robotics and Mechatronics (ICARM) (2022), Fig. 6(B), p. 5",
     "source_url": "https://doi.org/10.1109/icarm54641.2022.9959369",
     "where": "Fig. 6(B), p. 5",
     "licence": "publisher copyright"
    },
    {
     "id": "belharet_elfakir2022_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Magnetic catheter shape in a glass vessel model and simulation",
     "source_key": "elfakir2022_towards",
     "source": "Elfakir et al., 2022 IEEE/ASME International Conference on Advanced Intelligent Mechatronics (AIM) (2022), Fig. 6, p. 5",
     "source_url": "https://doi.org/10.1109/aim52237.2022.9863252",
     "where": "Fig. 6, p. 5",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "elfakir2022_towards",
     "doi": "10.1109/aim52237.2022.9863252",
     "url": null,
     "title": "Towards a Robust Steerability Magnetic Catheter with Haptic Force Feedback and Virtual Reality",
     "year": 2022,
     "venue": "2022 IEEE/ASME International Conference on Advanced Intelligent Mechatronics (AIM)"
    },
    {
     "key": "elfakir2022_magnetic",
     "doi": "10.1109/icarm54641.2022.9959369",
     "url": null,
     "title": "Magnetic Catheter Optimized for Navigation in a Complex Vascular Network",
     "year": 2022,
     "venue": "2022 International Conference on Advanced Robotics and Mechatronics (ICARM)"
    },
    {
     "key": "alekseeva2025_design",
     "doi": "10.1002/rob.22480",
     "url": null,
     "title": "The Design of Endovascular Robots for Cardiac Interventions: A Survey",
     "year": 2024,
     "venue": "Journal of Field Robotics"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (elfakir2022_towards, elfakir2022_magnetic)",
   "notes": "Family: magnetic. alekseeva2025_design Table 14 row 9 lists both 2022 papers as one system; the two papers use different field sources, kept as versions of one row. Thesis PDF behind an Anubis challenge on HAL: manual list.",
   "maintainers_own": false,
   "found_by": "actuated-tip"
  },
  {
   "schema_version": 1,
   "id": "mpi_tiryaki2023",
   "name": "7-T MRI steering",
   "full_name": "Ultrahigh-field magnetic guidewire steering inside a 7-T MRI scanner with a robotic MRI stage",
   "group": "Sitti, Physical Intelligence Department, Max Planck Institute for Intelligent Systems",
   "group_short": "MPI-IS",
   "family": "magnetic",
   "category": "magnetic-navigation",
   "first_year": 2023,
   "latest_year": 2023,
   "versions": "single (Sci. Adv. 2023)",
   "target_anatomy": "endovascular under MRI: renal artery, type 1 aortic arch, common carotid and middle cerebral artery glass models (tiryaki2023_magnetic Fig. 7); ex vivo porcine kidney renal cavity (non-vascular, Fig. 8)",
   "devices": [
    "guidewire",
    "catheter"
   ],
   "devices_driven": "own guidewire: MRI-compatible glass fibre-optic rod core with NdFeB tip magnets (1 mm x 1 mm cylinders) in parallel, perpendicular, antiparallel or dual configurations; 900 um Teflon supporting catheter (tiryaki2023_magnetic Results)",
   "n_dof": null,
   "n_dof_detail": "robotic MRI stage: x, y and yaw; manual insertion and base twist (tiryaki2023_magnetic Results, Fig. 5A)",
   "translation_mechanism": "magnetic",
   "translation_detail": "magnetic (tip steering by MRI main-field torque and fringe-field gradient); insertion by hand (tiryaki2023_magnetic Fig. 5A, Fig. 7)",
   "rotation_mechanism": "magnetic-field",
   "rotation_detail": "motorized stage moves and rotates the phantom relative to the main field; manual base twist (tiryaki2023_magnetic Results)",
   "device_range": "N.R.",
   "footprint_mm": "N.R. (inside a 7-T preclinical MRI bore)",
   "mass_kg": "N.R.",
   "force_sensing": "none during navigation (MRI-conditioned force sensor used only to calibrate magnet force)",
   "haptics_leader": "no: joystick / remote controller for the stage (tiryaki2023_magnetic Results)",
   "imaging_compat": "MRI (real-time 1-Hz FISP in the kidney test; tip seen as a 37 x 29 mm susceptibility artefact) (tiryaki2023_magnetic Fig. 8)",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "3D glass vascular models with physiological flow (renal artery, aortic arch at 100 mL per beat, CCA, MCAs), access through a Teflon port 40 cm from the target (tiryaki2023_magnetic Fig. 7); 2D obstacle tasks with three targets (Fig. 5); ex vivo porcine kidney renal cavity under real-time MRI, guidewire through the urinary tract, not a vessel (Fig. 8)",
   "key_numbers": "7 T; fringe gradients up to 20 T/m at the bore entrance; tip workspace 161 deg at 7 T (Fig. 3C); antiparallel magnet rotates up to 164 deg; platform rotation up to 48 deg needed in 2D tasks (tiryaki2023_magnetic Results)",
   "sim_model": "Cosserat rod model (20 segments) with a UHF magnetization model, used for guidewire design (tiryaki2023_magnetic Methods)",
   "has_sim_model": true,
   "sim2real": "none-found",
   "sim2real_detail": "none found (model used for design, no trained controller)",
   "picture": {
    "status": "cleared",
    "grade": "C",
    "kind": "render",
    "source": "tiryaki2023_magnetic Fig. 1(A) (PMC10132757 figure file sciadv.adg6438-f1.jpg)",
    "source_url": "https://doi.org/10.1126/sciadv.adg6438",
    "licence": "CC BY 4.0",
    "credit": "Tiryaki et al., Science Advances (2023), Fig. 1. CC BY 4.0.",
    "edits": "cropped panel A from the 785 px PMC figure; panel letter removed by crop; none upscaled",
    "file": "pictures/mpi_tiryaki2023.jpg"
   },
   "pictures": [
    {
     "id": "mpi_tiryaki2023_01",
     "status": "cleared",
     "file": "pictures/extra/mpi_tiryaki2023_01.jpg",
     "thumb": "pictures/thumbs/mpi_tiryaki2023_01.jpg",
     "kind": "in-use",
     "caption": "Guidewire steering in renal, arch, carotid and cerebral glass models",
     "source_key": "tiryaki2023_magnetic",
     "source": "Tiryaki et al., Science Advances (2023), Fig. 7",
     "source_url": "https://doi.org/10.1126/sciadv.adg6438",
     "where": "Fig. 7",
     "licence": "CC BY 4.0"
    },
    {
     "id": "mpi_tiryaki2023_02",
     "status": "cleared",
     "file": "pictures/extra/mpi_tiryaki2023_02.jpg",
     "thumb": "pictures/thumbs/mpi_tiryaki2023_02.jpg",
     "kind": "in-use",
     "caption": "Obstacle tasks with three tip-magnet configurations inside the 7-T scanner",
     "source_key": "tiryaki2023_magnetic",
     "source": "Tiryaki et al., Science Advances (2023), Fig. 5",
     "source_url": "https://doi.org/10.1126/sciadv.adg6438",
     "where": "Fig. 5",
     "licence": "CC BY 4.0"
    }
   ],
   "sources": [
    {
     "key": "tiryaki2023_magnetic",
     "doi": "10.1126/sciadv.adg6438",
     "url": null,
     "title": "Magnetic guidewire steering at ultrahigh magnetic fields",
     "year": 2023,
     "venue": "Science Advances"
    },
    {
     "key": "konda2025_robotically",
     "doi": "10.1126/scirobotics.adt7461",
     "url": null,
     "title": "Robotically steerable guidewires—Current trends and future directions",
     "year": 2025,
     "venue": "Science Robotics"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (PMC full text)",
   "notes": "Family: magnetic. konda2025 Table 2 row 4. The guidewire is advanced by hand; motor control is the stage that moves the phantom in the field. No photo of the stage in the paper body (fig. S7 in the supplement, not opened: manual list).",
   "maintainers_own": false,
   "found_by": "actuated-tip"
  },
  {
   "schema_version": 1,
   "id": "chonnam_jeong2017",
   "name": "PCI magnetic wire",
   "full_name": "Magnetically steerable PCI guidewire with a Helmholtz-coil EMA and a motorized feeding stage",
   "group": "J.-O. Park, S. Park, C.-S. Kim, Chonnam National University and Korea Medical Microrobot Center",
   "group_short": "Chonnam NU",
   "family": "magnetic",
   "category": "magnetic-navigation",
   "first_year": 2017,
   "latest_year": 2019,
   "versions": "2017: two pairs of Helmholtz coils + motorized feeding stage, feed-forward + PID steering (jeong2017_feasibility); 2019: EMA of two Helmholtz pairs and one Maxwell pair (one x-axis pair used) + linear-stage feeder, path regeneration, feeding control and vision tracking (kim2019_novel); 2018-21: same group's guide-wired helical microrobot (GHM) for mechanical atherectomy: 3D-printed corkscrew head (1.6 x 9.5 mm, NdFeB magnet magnetised across the axis) on a spherical joint at the tip of a 0.152 mm nitinol guidewire, steered by a uniform field and spun for drilling by a rotating field (18-370 Hz, resonant circuits) of three Helmholtz-coil pairs (30 mT), advanced and retracted by a motorised linear-stage feeder in an automatic tracing mode; in vitro feasibility (Nguyen 2018 EMBC); phantom path tracking, gelatin-thrombus drilling and 5 rats in vivo (Nguyen 2021 IEEE TBME 68:2490-2498, Secs. II-IV, Figs. 2, 4) (Konda 2025 Table 2 row 8) (nguyen2021_guidewired; konda2025_robotically)",
   "target_anatomy": "coronary (PCI), tested in planar vessel phantoms; 2021: chronic total occlusion; rat abdominal aorta used as a coronary-size model (nguyen2021_guidewired Sec. IV-G)",
   "devices": [
    "guidewire",
    "catheter",
    "sheath"
   ],
   "devices_driven": "2017: Asahi Conquest Pro 12 guidewire (tip OD 0.23 mm) with a bullet-shaped NdFeB magnet 1 mm x 7 mm (jeong2017_feasibility Sec. 2.1); 2019: 0.2 mm nitinol wire with a magnet tip (kim2019_novel Sec. 4.1); 2021: 0.152 mm super-elastic nitinol guidewire (Confluent Medical) carrying the 3D-printed helical head; 130 mm of wire through a Tygon sheath (0.79 mm ID) as guiding catheter (nguyen2021_guidewired Secs. II-A, IV-A)",
   "n_dof": 2,
   "n_dof_detail": "2: insertion (feeder) + planar tip steering (field); 2021: insertion (feeder) + 3-D steering and spin of the head (field)",
   "translation_mechanism": "linear-stage+clamp",
   "translation_detail": "linear-stage+clamp (motorized feeding stage with a guidewire holder, jeong2017_feasibility abstract; linear stage, kim2019_novel Fig. 1); tip steered magnetically",
   "rotation_mechanism": "magnetic-field",
   "rotation_detail": "field direction of the Helmholtz coils (no shaft rotation); 2021: a rotating field spins the helical head on its spherical joint; the guidewire does not turn (nguyen2021_guidewired Secs. II-A, III)",
   "device_range": "N.R.",
   "footprint_mm": "Helmholtz coil radius 162 mm, region of interest 100 x 100 (kim2019_novel Sec. 2.1)",
   "mass_kg": "N.R.",
   "force_sensing": "none",
   "haptics_leader": "no",
   "imaging_compat": "overhead CCD camera only (jeong2017_feasibility Sec. 3.1; kim2019_novel); 2021: optical camera on the phantom, C-arm X-ray (Ziehm Vision RFD) in the rat study (nguyen2021_guidewired Sec. IV-A)",
   "sterility": "N.R.",
   "highest_validation": "animal",
   "validation_detail": "2017: five-branch phantom (about 4 mm branches), insertion success 100% with feed-forward + PID vs about 75% with feed-forward only (jeong2017_feasibility Sec. 3.3); 2019: smooth and sharply curved vessel phantoms, 3 paths x 3 replicates (kim2019_novel Sec. 4, Table 1); 2021: 5 rats in vivo (abdominal aorta, injected 9 % gelatin thrombus, contrast angiography): thrombus drilled without perforation in 3, blood flow restored in 2, rats 1 and 2 died during thrombus formation and rat 3 of bleeding after drilling; vessel phantom path tracking RMSE about 0.2 mm, maximum below 0.7 mm at 0.3 mm/s; gelatin thrombi in tubes drilled through, 54 mm (9 %) in about 48 s and 40 mm (11 %) in 43 s (nguyen2021_guidewired Secs. IV-D to IV-G, Table II, Figs. 6-8)",
   "key_numbers": "steering-angle error below 0.5 deg with PID vs about 7 deg feed-forward only (jeong2017_feasibility Sec. 3.2); tip-position RMSE 0.44 +/- 0.19 mm on path I, below 0.7 +/- 0.4 mm on all paths; feeding speed 1 mm/s; camera 0.1 mm per pixel (kim2019_novel Sec. 3-4); 2021: three Helmholtz pairs on three 15 kW supplies, 30 mT, rotating field up to 370 Hz; drilling force up to 0.8 N and torque 0.1125 mN m at 100 Hz; feedback steering error below 0.5 deg (maximum 0.52 deg) against about 3 deg feed-forward (nguyen2021_guidewired Secs. III, IV-A, IV-D)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "photo",
    "source": "kim2019_novel Fig. 1",
    "source_url": "https://doi.org/10.1007/s12555-018-0116-8",
    "licence": "publisher copyright",
    "credit": "Kim et al., International Journal of Control, Automation and Systems (2019), Fig. 1. publisher copyright.",
    "edits": "native extract from kim2019_tip-positioning_IJCAS.pdf p. 3; no crop; none upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "chonnam_jeong2017_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Helmholtz coils, camera, guidewire device and motorized feeding stage",
     "source_key": "jeong2017_feasibility",
     "source": "Jeong et al., International Journal of Control, Automation and Systems (2016), Fig. 2(b), p. 3",
     "source_url": "https://doi.org/10.1007/s12555-015-0269-7",
     "where": "Fig. 2(b), p. 3",
     "licence": "publisher copyright"
    },
    {
     "id": "chonnam_jeong2017_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Helmholtz-coil EMA, feeding device, resonant circuit and C-arm in the shielded room",
     "source_key": "nguyen2021_guidewired",
     "source": "Nguyen et al., IEEE Transactions on Biomedical Engineering (2021), Fig. 4(a), p. 2493",
     "source_url": "https://doi.org/10.1109/tbme.2020.3046513",
     "where": "Fig. 4(a), p. 2493",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "chonnam_jeong2017_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "3D-printed helical microrobot head on the end of the guidewire",
     "source_key": "nguyen2021_guidewired",
     "source": "Nguyen et al., IEEE Transactions on Biomedical Engineering (2021), Fig. 2(b), p. 2491",
     "source_url": "https://doi.org/10.1109/tbme.2020.3046513",
     "where": "Fig. 2(b), p. 2491",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "chonnam_jeong2017_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Helical head drilling through a 54 mm gelatin thrombus in a tube over 48 s",
     "source_key": "nguyen2021_guidewired",
     "source": "Nguyen et al., IEEE Transactions on Biomedical Engineering (2021), Fig. 6(c), p. 2494",
     "source_url": "https://doi.org/10.1109/tbme.2020.3046513",
     "where": "Fig. 6(c), p. 2494",
     "licence": "publisher copyright (IEEE)"
    }
   ],
   "sources": [
    {
     "key": "jeong2017_feasibility",
     "doi": "10.1007/s12555-015-0269-7",
     "url": null,
     "title": "Feasibility study on magnetically steerable guidewire device for percutaneous coronary intervention",
     "year": 2016,
     "venue": "International Journal of Control, Automation and Systems"
    },
    {
     "key": "kim2019_novel",
     "doi": "10.1007/s12555-018-0116-8",
     "url": null,
     "title": "A Novel Tip-positioning Control of a Magnetically Steerable Guidewire in Sharply Curved Blood Vessel for Percutaneous Coronary Intervention",
     "year": 2019,
     "venue": "International Journal of Control, Automation and Systems"
    },
    {
     "key": "konda2025_robotically",
     "doi": "10.1126/scirobotics.adt7461",
     "url": null,
     "title": "Robotically steerable guidewires—Current trends and future directions",
     "year": 2025,
     "venue": "Science Robotics"
    },
    {
     "key": "nguyen2021_guidewired",
     "doi": "10.1109/tbme.2020.3046513",
     "url": null,
     "title": "Guide-Wired Helical Microrobot for Percutaneous Revascularization in Chronic Total Occlusion <i>in-Vivo</i> Validation",
     "year": 2021,
     "venue": "IEEE Transactions on Biomedical Engineering"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (jeong2017_feasibility, kim2019_novel, nguyen2021_guidewired)",
   "notes": "Family: magnetic. konda2025 Table 2 rows 5 and 7. The same group's guide-wired helical microrobot (Nguyen 2021 TBME, konda2025 row 8) was judged 'unclear' in review_coverage and is not added. | N4 2026-11-09: nguyen2021_guidewired read in full (the 'not added' sentence above predates N3, which filed the helical microrobot as a version line): same group's three-pair Helmholtz EMA with a motorised linear-stage feeder; 5 rats in vivo, so highest_validation phantom -> animal; C-arm X-ray added to imaging; first_year and latest_year kept at 2017 and 2019, as for every round-8 version line",
   "maintainers_own": false,
   "found_by": "actuated-tip"
  },
  {
   "schema_version": 1,
   "id": "polymtl_gosselin2011",
   "name": "MRN platform",
   "full_name": "MRI-based magnetic resonance navigation platform steering bead-tipped catheters and guidewires with added gradient coils",
   "group": "Martel, NanoRobotics Laboratory, Polytechnique Montreal (with Soulez, CHUM, for the animal study)",
   "group_short": "Polytechnique",
   "family": "magnetic",
   "category": "magnetic-navigation",
   "first_year": 2011,
   "latest_year": 2015,
   "versions": "2011: catheter with ferromagnetic spheres steered by MRI gradients, deflection characterised (gosselin2011_characterization, review-only); MRN platform with a propulsion and imaging coil insert in a 1.5-T Siemens Sonata (vonthron2011_mri); 2015: guidewire with a ferromagnetic bead steered in 2 rabbits (lalande2015_vivo, abstract)",
   "target_anatomy": "selective catheterization of aortic branches (renal, superior mesenteric and iliac arteries) in rabbits (lalande2015_vivo abstract)",
   "devices": [
    "guidewire",
    "catheter"
   ],
   "devices_driven": "2.5 Fr catheter (FasTracker 018, Boston Scientific) with two 0.9 mm chrome-steel beads 1.6 mm apart (vonthron2011_mri Sec. VII-A); guidewire with a magnetic bead at its tip (lalande2015_vivo abstract)",
   "n_dof": null,
   "n_dof_detail": "3D gradient force on the tip bead (three propulsion gradient axes, vonthron2011_mri Sec. IV)",
   "translation_mechanism": "magnetic",
   "translation_detail": "magnetic (gradient-force steering of the tip); advance N.R. in the abstract (manual per li2020_magnetic Sec. 4.1: 'blindly controlled' between tracking sequences)",
   "rotation_mechanism": "magnetic-field",
   "rotation_detail": "gradient direction of the added coils",
   "device_range": "N.R.",
   "footprint_mm": "N.R. (coil insert inside a clinical 1.5-T bore, vonthron2011_mri Fig. 2)",
   "mass_kg": "N.R.",
   "force_sensing": "none",
   "haptics_leader": "no",
   "imaging_compat": "MRI tracking sequence interleaved with propulsion (imaging and propulsion mutually exclusive, vonthron2011_mri Fig. 3); MRA roadmap and dedicated tracking (lalande2015_vivo abstract)",
   "sterility": "N.R.",
   "highest_validation": "animal",
   "validation_detail": "2 rabbits: selective catheterization of right and left renal arteries successful and reproducible, SMA and iliac feasible, no inadvertent side-branch entry when advanced without actuation (lalande2015_vivo abstract); catheter deflection in a water bath for gradients -400 to +400 mT/m in Maxwell coils and in the propulsion insert (vonthron2011_mri Sec. VII-A, Figs. 5-7)",
   "key_numbers": "propulsion insert up to 450 mT/m in three directions; minimum coil rise time 20 ms; clinical imaging gradients about 20 mT/m effective (40 mT/m nominal) on a Siemens Sonata (vonthron2011_mri Sec. III-IV)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "photo",
    "source": "vonthron2011_mri Fig. 2",
    "source_url": "https://doi.org/10.1109/iros.2011.6094721",
    "licence": "publisher copyright",
    "credit": "Vonthron et al., 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems (2011), Fig. 2. publisher copyright.",
    "edits": "native extract from vonthron2011_mri-platform_IROS.pdf p. 3; no crop; none upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "polymtl_gosselin2011_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Catheter and camera inside the propulsion coil insert",
     "source_key": "vonthron2011_mri",
     "source": "Vonthron et al., 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems (2011), Fig. 6(a), p. 5",
     "source_url": "https://doi.org/10.1109/iros.2011.6094721",
     "where": "Fig. 6(a), p. 5",
     "licence": "publisher copyright"
    },
    {
     "id": "polymtl_gosselin2011_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Catheter deflection test between a pair of Maxwell coils",
     "source_key": "vonthron2011_mri",
     "source": "Vonthron et al., 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems (2011), Fig. 5(a), p. 5",
     "source_url": "https://doi.org/10.1109/iros.2011.6094721",
     "where": "Fig. 5(a), p. 5",
     "licence": "publisher copyright"
    },
    {
     "id": "polymtl_gosselin2011_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Catheter tip with two ferromagnetic beads",
     "source_key": "vonthron2011_mri",
     "source": "Vonthron et al., 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems (2011), Fig. 4, p. 4",
     "source_url": "https://doi.org/10.1109/iros.2011.6094721",
     "where": "Fig. 4, p. 4",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "vonthron2011_mri",
     "doi": "10.1109/iros.2011.6094721",
     "url": null,
     "title": "A MRI-based integrated platform for the navigation of micro-devices and microrobots",
     "year": 2011,
     "venue": "2011 IEEE/RSJ International Conference on Intelligent Robots and Systems"
    },
    {
     "key": "lalande2015_vivo",
     "doi": "10.1118/1.4906194",
     "url": null,
     "title": "In vivo demonstration of magnetic guidewire steerability in a MRI system with additional gradient coils",
     "year": 2015,
     "venue": "Medical Physics"
    },
    {
     "key": "gosselin2011_characterization",
     "doi": "10.1118/1.3622599",
     "url": null,
     "title": "Characterization of the deflections of a catheter steered using a magnetic resonance imaging system",
     "year": 2011,
     "venue": "Medical Physics"
    },
    {
     "key": "li2020_magnetic",
     "doi": "10.1007/s11370-020-00311-0",
     "url": null,
     "title": "A review of magnetic actuation systems and magnetically actuated guidewire- and catheter-based microrobots for vascular interventions",
     "year": 2020,
     "venue": "Intelligent Service Robotics"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (vonthron2011_mri); abstract (lalande2015_vivo); review-only (gosselin2011_characterization via li2020_magnetic Sec. 4.2)",
   "notes": "Family: magnetic. The group's untethered MRN (1.5 mm sphere in a swine carotid) is out of scope. Lalande 2015 and Gosselin 2011 are Med. Phys. (Wiley): manual list; Lalande Fig. (in vivo setup) would be the better picture.",
   "maintainers_own": false,
   "found_by": "actuated-tip"
  },
  {
   "schema_version": 1,
   "id": "marc_losey2014",
   "name": "MARC catheter",
   "full_name": "MARC (magnetically assisted remote-controlled) catheter steered by tip-coil current in the MRI field",
   "group": "Hetts, Department of Radiology and Biomedical Imaging, UCSF",
   "group_short": "UCSF",
   "family": "magnetic",
   "category": "magnetic-navigation",
   "first_year": 2013,
   "latest_year": 2016,
   "versions": "2013: microcatheter tip deflection protocol (hetts2013_magnetically, JoVE); 2014: 2 mm catheter with a solenoid tip coil, foot pedal delivers +/-300 mA (losey2014_magnetically); 2015: 1.6 mm laser-lithographed dual-axis saddle coils, 1.5 T and 3 T (moftakhar2015_new); 2016: intramural copper-braided catheter with a saddle coil, in-room current cart (lillaney2016_endovascular)",
   "target_anatomy": "interventional MRI: abdominal aortic branch catheterization, renal artery embolization",
   "devices": [
    "microcatheter"
   ],
   "devices_driven": "own MARC microcatheters: 2 mm with solenoid coil at the tip (losey2014_magnetically abstract); 1.6 mm with double-saddle coils (moftakhar2015_new abstract)",
   "n_dof": null,
   "n_dof_detail": "tip deflection in 1 axis (2014) or 2 axes (2015); advance and twist by hand",
   "translation_mechanism": "magnetic",
   "translation_detail": "magnetic (Lorentz torque on the current-carrying tip coil in the MRI main field); insertion by hand",
   "rotation_mechanism": "magnetic-field",
   "rotation_detail": "tip deflection set by coil current direction and magnitude",
   "device_range": "catheter OD 2 mm (2014), 1.6 mm (2015)",
   "footprint_mm": "N.R. (clinical MRI scanner)",
   "mass_kg": "N.R.",
   "force_sensing": "none",
   "haptics_leader": "no: foot pedal (losey2014_magnetically) or in-room cart (lillaney2016_endovascular)",
   "imaging_compat": "real-time MRI at 1.5 T (bSSFP) and 3 T; compared with x-ray fluoroscopy",
   "sterility": "N.R.",
   "highest_validation": "animal",
   "validation_detail": "3 farm pigs (43 +/- 2 kg): MR-guided MARC renal artery embolization with the contralateral kidney under x-ray; embolization successful in all 6 kidneys (lillaney2016_endovascular abstract); in vitro cryogel abdominal aortic phantom: 192/240 (80%) turns with magnetic assistance vs 144/240 (60%) without (losey2014_magnetically abstract)",
   "key_numbers": "tip current 300 mA (losey2014_magnetically); MR-guided catheterization 93 +/- 56 s vs 60 +/- 22 s under x-ray (lillaney2016_endovascular); inexperienced operators 67% (1.5 T) and 75% (3 T) successful turns vs 76% under x-ray (moftakhar2015_new)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "photo",
    "source": "li2020_magnetic Fig. 8e(B), reproduced there from losey2014_magnetically Fig. 1B",
    "source_url": "https://doi.org/10.1007/s11370-020-00311-0",
    "licence": "publisher copyright",
    "credit": "Hwang et al., Intelligent Service Robotics (2020), Fig. 8e. publisher copyright.",
    "edits": "native extract from li2020_magnetic_ISR.pdf p. 9; cropped to panel B (panel letter removed); '2 mm' and '10 mm' labels kept; none upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "marc_losey2014_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "MARC tip schematic, prototype and MR images of deflection",
     "source_key": "losey2014_magnetically",
     "source": "Losey et al., Radiology (2014), Fig. 1, PMC4065602",
     "source_url": "https://doi.org/10.1148/radiol.14132041",
     "where": "Fig. 1, PMC4065602",
     "licence": "publisher copyright"
    },
    {
     "id": "marc_losey2014_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Laser-lithographed coil on the microcatheter tip",
     "source_key": "hetts2013_magnetically",
     "source": "Hetts et al., Journal of Visualized Experiments (2013), Fig. 5, PMC3643177",
     "source_url": "https://doi.org/10.3791/50299",
     "where": "Fig. 5, PMC3643177",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "losey2014_magnetically",
     "doi": "10.1148/radiol.14132041",
     "url": null,
     "title": "Magnetically Assisted Remote-controlled Endovascular Catheter for Interventional MR Imaging: In Vitro Navigation at 1.5 T versus X-ray Fluoroscopy",
     "year": 2014,
     "venue": "Radiology"
    },
    {
     "key": "lillaney2016_endovascular",
     "doi": "10.1148/radiol.2016152036",
     "url": null,
     "title": "Endovascular MR-guided Renal Embolization by Using a Magnetically Assisted Remote-controlled Catheter System",
     "year": 2016,
     "venue": "Radiology"
    },
    {
     "key": "moftakhar2015_new",
     "doi": "10.1148/radiol.2015142648",
     "url": null,
     "title": "New-Generation Laser-lithographed Dual-Axis Magnetically Assisted Remote-controlled Endovascular Catheter for Interventional MR Imaging: In Vitro Multiplanar Navigation at 1.5 T and 3 T versus X-ray Fluoroscopy",
     "year": 2015,
     "venue": "Radiology"
    },
    {
     "key": "hetts2013_magnetically",
     "doi": "10.3791/50299",
     "url": null,
     "title": "Magnetically-Assisted Remote Controlled Microcatheter Tip Deflection under Magnetic Resonance Imaging",
     "year": 2013,
     "venue": "Journal of Visualized Experiments"
    },
    {
     "key": "li2020_magnetic",
     "doi": "10.1007/s11370-020-00311-0",
     "url": null,
     "title": "A review of magnetic actuation systems and magnetically actuated guidewire- and catheter-based microrobots for vascular interventions",
     "year": 2020,
     "venue": "Intelligent Service Robotics"
    }
   ],
   "read_level": "abstract",
   "read_level_detail": "abstract + figures (PMC author manuscripts of losey2014, lillaney2016, moftakhar2015; hetts2013)",
   "notes": "Family: magnetic. Steering by current in the tip coil, insertion by hand; no bedside drive. No photo of the whole set-up (MRI room, current cart) in the four papers' figures; the picture is the catheter itself.",
   "maintainers_own": false,
   "found_by": "actuated-tip"
  },
  {
   "schema_version": 1,
   "id": "hanyang_lee2020",
   "name": "MCR in CMNS",
   "full_name": "Multifunctional magnetic catheter robot (MCR) in a closed-loop magnetic navigation system (CMNS)",
   "group": "G. Jang, Department of Mechanical Engineering, Hanyang University",
   "group_short": "Hanyang U.",
   "family": "magnetic",
   "category": "magnetic-navigation",
   "first_year": 2020,
   "latest_year": 2021,
   "versions": "CMNS hardware: 8 electromagnets at the vertices of a hexahedron with a back yoke (nam2018_magnetic); MCR with steering, tunnelling and stent-delivery motions (lee2021_steering, online 2020-01-15, IEEE TIE 68(1) 2021)",
   "target_anatomy": "occlusive vascular disease (angioplasty: steering, clot tunnelling, stent delivery) (lee2021_steering Sec. I)",
   "devices": [
    "guidewire",
    "therapeutic-device"
   ],
   "devices_driven": "own MCR: tube with a diametrically magnetized front magnet and drill tip, magnetic joint, two tension springs (26 N/m total), self-expandable stent; max OD 3.5 mm (about 10 Fr), min ID 0.4 mm passes a 0.014-in guidewire (lee2021_steering Sec. IV-A)",
   "n_dof": null,
   "n_dof_detail": "field direction, magnitude and rotation from 8 electromagnets: steering (static field), tunnelling (rotating field), stent release (field magnitude) (lee2021_steering Sec. II-C)",
   "translation_mechanism": "magnetic",
   "translation_detail": "magnetic (tip steering); advance mechanism N.R. (lee2021_steering)",
   "rotation_mechanism": "magnetic-field",
   "rotation_detail": "rotating field (20 mT, 12 Hz) spins the front magnet and drill tip for tunnelling (lee2021_steering Sec. IV-B)",
   "device_range": "MCR OD 3.5 mm",
   "footprint_mm": "cylindrical workspace up to 500 diameter (lee2021_steering Sec. II-B)",
   "mass_kg": "N.R.",
   "force_sensing": "none",
   "haptics_leader": "no: joystick controller (lee2021_steering Fig. 3b)",
   "imaging_compat": "biplane cameras (CMOS, 30 fps) only (lee2021_steering Sec. II-B, IV-B)",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "in vitro only: obstacle table with 4 steering points; stent-release threshold in a straight glass tube (10 trials); stent deployment accuracy in a branched 8 mm glass tube, 10 trials each for MCR and a conventional catheter; Y-shaped water-filled glass tube with a 5% agar clot: steer, tunnel, deploy stent, return (lee2021_steering Sec. IV)",
   "key_numbers": "steering at 20 mT; tunnelling at 20 mT, 12 Hz; stent release at 78.5 mT on average (theory 59 mT), 100% above 80 mT; stent position error 2.30 +/- 0.34 mm vs 8.79 +/- 0.69 mm for a conventional delivery catheter (lee2021_steering Sec. IV-B)",
   "sim_model": "none found (dynamic model of the magnetic joint for design, lee2021_steering Sec. III)",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "photo",
    "source": "lee2021_steering Fig. 3(b), right photo",
    "source_url": "https://doi.org/10.1109/tie.2020.2965480",
    "licence": "publisher copyright",
    "credit": "Lee et al., IEEE Transactions on Industrial Electronics (2021), Fig. 3(b). publisher copyright.",
    "edits": "native extract from lee2021_multifunctional-magnetic-catheter_TIE.pdf p. 3; cropped to the CMNS frame; none upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "hanyang_lee2020_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Catheter robot parts before and after assembly",
     "source_key": "lee2021_steering",
     "source": "Lee et al., IEEE Transactions on Industrial Electronics (2021), Fig. 8, p. 7",
     "source_url": "https://doi.org/10.1109/tie.2020.2965480",
     "where": "Fig. 8, p. 7",
     "licence": "publisher copyright"
    },
    {
     "id": "hanyang_lee2020_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Clot tunnelling and stent delivery in a Y-shaped glass vessel",
     "source_key": "lee2021_steering",
     "source": "Lee et al., IEEE Transactions on Industrial Electronics (2021), Fig. 12, p. 9",
     "source_url": "https://doi.org/10.1109/tie.2020.2965480",
     "where": "Fig. 12, p. 9",
     "licence": "publisher copyright"
    },
    {
     "id": "hanyang_lee2020_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Front view of the eight electromagnets around the workspace",
     "source_key": "lee2021_steering",
     "source": "Lee et al., IEEE Transactions on Industrial Electronics (2021), Fig. 3(b) left, p. 3",
     "source_url": "https://doi.org/10.1109/tie.2020.2965480",
     "where": "Fig. 3(b) left, p. 3",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "lee2021_steering",
     "doi": "10.1109/tie.2020.2965480",
     "url": null,
     "title": "Steering, Tunneling, and Stent Delivery of a Multifunctional Magnetic Catheter Robot to Treat Occlusive Vascular Disease",
     "year": 2021,
     "venue": "IEEE Transactions on Industrial Electronics"
    },
    {
     "key": "nam2018_magnetic",
     "doi": "10.1109/tie.2017.2782220",
     "url": null,
     "title": "Magnetic Navigation System Utilizing a Closed Magnetic Circuit to Maximize Magnetic Field and a Mapping Method to Precisely Control Magnetic Field in Real Time",
     "year": 2018,
     "venue": "IEEE Transactions on Industrial Electronics"
    },
    {
     "key": "zhao2022_remote",
     "doi": "10.21037/qims-21-792",
     "url": null,
     "title": "Remote vascular interventional surgery robotics: a literature review",
     "year": 2022,
     "venue": "Quantitative Imaging in Medicine and Surgery"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (lee2021_steering); figures only (nam2018_magnetic)",
   "notes": "Family: magnetic. zhao2022 Table 1 row 17b. Same university as hanyang_crr_kim2023 but a different lab (Jang, not Yi).",
   "maintainers_own": false,
   "found_by": "actuated-tip"
  },
  {
   "schema_version": 1,
   "id": "nit_nakazato2017",
   "name": "Peristaltic catheter",
   "full_name": "Peristaltically propelled active catheter: hydraulic two-balloon self-propelling catheter for the radial artery, driven by motorised syringes",
   "group": "Nippon Institute of Technology, Department of Innovative Systems Engineering (Yuichi Nakazato, K. Takita, M. Higuchi; K. Kawanaka) (nakazato2017_peristaltic p. 79)",
   "group_short": "Nippon IT",
   "family": "tip",
   "category": "actuated-device",
   "first_year": 2010,
   "latest_year": 2017,
   "versions": "2010: in-pipe micro mobile robot using peristalsis, hydraulic (nakazato2010_inpipe, J. Mech. Sci. Technol. 24:51-54; MAMM 2010), the mechanism the lab later tested 'using pseudoblood vessels with an inner diameter of <=6 mm ... assuming that the catheter is inserted in a femoral artery' (nakazato2017 Abstract; 2010 papers title only) -> 2016/2017: radial-artery catheter, section A 5 mm + section B 5/6/7 mm, phi 2.0 x 23.0 mm (nakazato2017_peristaltic Sec. 3.1, Figs. 2-3; MAMM-2016 proceedings, Springer 2017)",
   "target_anatomy": "radial-artery access for coronary treatment (radial ID 2.0-3.5 mm, Abstract); tested in silicone tubes of ID 2.5 and 3.0 mm and in the right internal and external carotid arteries of an endovascular surgery simulator (EVE, FAIN-Biomedical) (Sec. 4.2, 5.2)",
   "devices": [
    "guidewire",
    "catheter"
   ],
   "devices_driven": "its own active catheter, self-propelled: 'a self-propelled active catheter was realized without a guide wire' (Sec. 2); no off-the-shelf device",
   "n_dof": 1,
   "n_dof_detail": "1: forward locomotion by a travelling wave of two alternately inflated sections A and B; no steering, no rotation (Sec. 2, Fig. 1)",
   "translation_mechanism": "other",
   "translation_detail": "other: peristaltic self-propulsion inside the vessel: saline pressure-fed and aspirated alternately in balloon sections A and B, which grip the wall by friction and extend (Sec. 2, Fig. 1)",
   "rotation_mechanism": "none",
   "rotation_detail": "none",
   "device_range": "catheter phi 2.0 mm x 23.0 mm, feeding pipe phi 0.4 mm (Fig. 3); balloon sections of silicone rubber OD 0.8 mm, wall 0.12 mm, joined by silicone tubes OD 0.4 / ID 0.3 mm (Sec. 3.1)",
   "footprint_mm": "actuator: two syringe-and-linear-slider units in parallel, each 323.5 x 111.0 mm (Figs. 4-5 captions); connected to the catheter by a 1 m silicone tube (ID 0.5, OD 1.0 mm) (Sec. 3.2)",
   "mass_kg": "N.R.",
   "force_sensing": "none",
   "haptics_leader": "none (feed sequence of the two syringes; operator interface N.R.)",
   "imaging_compat": "N.R. (photographed in a transparent simulator)",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "phantom: forward driving over 30 mm in silicone tubes (ID 2.5 and 3.0 mm, Young's modulus 1.7 MPa, water-glycerin pseudo-blood 5.0 mPa s) at feeding rates 140-570 ul/s (Sec. 4.2-4.4, Table 1, Fig. 7); EVE simulator: moved forward in the right internal and external carotid arteries at radii of curvature up to 1.2 cm, moved backward at 0.8 cm (Sec. 5.3, Fig. 9). Number of runs N.R.",
   "key_numbers": "max speed 4.79 mm/s at 570 ul/s and 370 ul feed (Sec. 4.4); design target 5 mm/s (Sec. 3.1); feed volume 230-400 ul (Sec. 4.3); catheter phi 2.0 x 23.0 mm (Fig. 3)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "photo",
    "source": "nakazato2017_peristaltic Fig. 5 (syringes on two stepping-motor linear sliders), p. 84",
    "source_url": "https://doi.org/10.1007/978-3-319-45387-3_8",
    "licence": "publisher copyright (Springer)",
    "credit": "Nakazato et al., Microactuators and Micromechanisms (2016), Fig. 5. publisher copyright (Springer).",
    "edits": "native embedded raster extracted (CMYK converted to RGB); no crop; no edit; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "nit_nakazato2017_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "The 23 mm active catheter with its feeding pipe on a ruler",
     "source_key": "nakazato2017_peristaltic",
     "source": "Nakazato et al., Microactuators and Micromechanisms (2016), Fig. 3, p. 83",
     "source_url": "https://doi.org/10.1007/978-3-319-45387-3_8",
     "where": "Fig. 3, p. 83",
     "licence": "publisher copyright (Springer)"
    },
    {
     "id": "nit_nakazato2017_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Catheter advancing in a carotid artery of the endovascular simulator",
     "source_key": "nakazato2017_peristaltic",
     "source": "Nakazato et al., Microactuators and Micromechanisms (2016), Fig. 9, p. 88",
     "source_url": "https://doi.org/10.1007/978-3-319-45387-3_8",
     "where": "Fig. 9, p. 88",
     "licence": "publisher copyright (Springer)"
    }
   ],
   "sources": [
    {
     "key": "nakazato2017_peristaltic",
     "doi": "10.1007/978-3-319-45387-3_8",
     "url": null,
     "title": "Development of Peristaltically Propelled Active Catheter Used in Radial Artery",
     "year": 2016,
     "venue": "Microactuators and Micromechanisms"
    },
    {
     "key": "nakazato2010_inpipe",
     "doi": "10.1007/s12206-009-1174-x",
     "url": null,
     "title": "Development of an In-pipe micro mobile robot using peristalsis motion",
     "year": 2010,
     "venue": "Journal of Mechanical Science and Technology"
    },
    {
     "key": "alekseeva2025_design",
     "doi": "10.1002/rob.22480",
     "url": null,
     "title": "The Design of Endovascular Robots for Cardiac Interventions: A Survey",
     "year": 2024,
     "venue": "Journal of Field Robotics"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (nakazato2017_peristaltic); title (nakazato2010_inpipe); review-only (alekseeva2025_design Table 14 row 6)",
   "notes": "N3 2026-11-08, from review_comparison Sec. 1.3 (Alekseeva Table 14 row 6, 'Peristaltically Propelled Active Catheter', ex vivo phantom TRL3). In scope as an actuated device: the catheter moves itself inside vessel models by fluid pressure, and the fluid is moved by syringes on electric sliders 'consisting of a stepping motor and ball screws' (XA-42-D, SUS Corp., Sec. 3.2). Alekseeva's 2010 reference is an in-pipe robot, not a catheter. Main picture is the drive; the catheter itself (Fig. 3) is in the gallery.",
   "maintainers_own": false,
   "found_by": "actuated-tip"
  },
  {
   "schema_version": 1,
   "id": "tsinghua_wang2023",
   "name": "MFCR",
   "full_name": "MFCR: magnetic-controlled flexible continuum robot with C, J and S deformation modes, steered by a three-dimensional electromagnet platform",
   "group": "Tsinghua University, State Key Laboratory of Tribology in Advanced Equipment (Zili Wang, Ding Weng, Zhaoxin Li, Lei Chen, Yuan Ma, Jiadao Wang) (wang2023_magnetic p. 1)",
   "group_short": "Tsinghua U.",
   "family": "magnetic",
   "category": "magnetic-navigation",
   "first_year": 2023,
   "latest_year": 2023,
   "versions": "single version (wang2023_magnetic, Actuators 12:247, 2023)",
   "target_anatomy": "coronary access through aorta-coronary bifurcations (PTCA-type guidewire navigation, Sec. 3.2); tested in 3D-printed ring channels (ID 4 mm, 30-130 deg), simplified aorta-left/right coronary models at three angles, and a Y-bifurcation with clay obstacles (Sec. 3.2-3.3, Figs. 5-6)",
   "devices": [
    "guidewire"
   ],
   "devices_driven": "its own magnetic soft continuum robot (guidewire-like): silicone elastomer with NdFeB powder (1:1 by mass) as the magnetic tip, nitinol-core silicone body (Sec. 2.2); advanced into the branch 'with the help of manual operation' (Sec. 3.2)",
   "n_dof": null,
   "n_dof_detail": "tip deformation set by the field direction and strength (three planar modes C, J, S); insertion by hand (Sec. 3)",
   "translation_mechanism": "magnetic",
   "translation_detail": "magnetic (steering); forward push by hand ('with the help of manual operation', Sec. 3.2)",
   "rotation_mechanism": "magnetic-field",
   "rotation_detail": "magnetic torque of the external field on the programmed magnetisation; no axial rotation (Sec. 2.1, 3.1)",
   "device_range": "magnetic part L = 15 mm (segments 6, 3 and 6 mm with different magnetisation), D = 1.5 mm (Sec. 3.1, Fig. 3)",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "none",
   "haptics_leader": "none (N.R.)",
   "imaging_compat": "optical: DSLR camera, camera above the testbed (Fig. 1c, Sec. 3.1); fluoroscopy N.R.",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "bench: static deformation in the three-dimensional electromagnet platform against the model, n = 3 per condition (Sec. 3.1, Fig. 4); phantom: passing 30-130 deg ring channels and aorta-coronary models with a permanent magnet (Fig. 5), and entering a branch past an obstacle with J and S modes in the electromagnet system (Fig. 6, Videos S1-S2)",
   "key_numbers": "C-shape field 19.7-127 mT; < 150 mT in all tests (Sec. 4); max mean angle error 2.979 deg and max mean tip-position error 0.328 mm (Sec. 5); J mode 0.589 / 0.499 deg and 0.103 mm (Sec. 4); magnetised at 1.5 T for 10 s (Sec. 2.2)",
   "sim_model": "yes: quasi-static model from magnetic plus elastic potential energy on an Euler-Bernoulli beam, solved in MATLAB to predict the deformation modes (wang2023_magnetic Sec. 2.1, 3.1)",
   "has_sim_model": true,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "cleared",
    "grade": "C",
    "kind": "render",
    "source": "wang2023_magnetic Fig. 1(c), p. 3",
    "source_url": "https://doi.org/10.3390/act12060247",
    "licence": "CC BY 4.0",
    "credit": "Wang et al., Actuators (2023), Fig. 1(c). CC BY 4.0.",
    "edits": "native embedded raster (two strips of 3418 px joined); cropped to panel (c), panel letter cropped off; labels 'Camera', 'MFCR', 'Magnetic System', 'Testbed' and their arrows kept (one arrow touches the MFCR); not upscaled",
    "file": "pictures/tsinghua_wang2023.jpg"
   },
   "pictures": [
    {
     "id": "tsinghua_wang2023_01",
     "status": "cleared",
     "file": "pictures/extra/tsinghua_wang2023_01.jpg",
     "thumb": "pictures/thumbs/tsinghua_wang2023_01.jpg",
     "kind": "in-use",
     "caption": "MFCR in J and S modes passing an obstacle into a branch under the electromagnet system",
     "source_key": "wang2023_magnetic",
     "source": "Wang et al., Actuators (2023), Fig. 6, p. 8",
     "source_url": "https://doi.org/10.3390/act12060247",
     "where": "Fig. 6, p. 8",
     "licence": "CC BY 4.0"
    },
    {
     "id": "tsinghua_wang2023_02",
     "status": "cleared",
     "file": "pictures/extra/tsinghua_wang2023_02.jpg",
     "thumb": "pictures/thumbs/tsinghua_wang2023_02.jpg",
     "kind": "in-use",
     "caption": "MFCR turning through 30-130 degree ring channels and aorta-coronary models",
     "source_key": "wang2023_magnetic",
     "source": "Wang et al., Actuators (2023), Fig. 5, p. 7",
     "source_url": "https://doi.org/10.3390/act12060247",
     "where": "Fig. 5, p. 7",
     "licence": "CC BY 4.0"
    }
   ],
   "sources": [
    {
     "key": "wang2023_magnetic",
     "doi": "10.3390/act12060247",
     "url": null,
     "title": "A Magnetic-Controlled Flexible Continuum Robot with Different Deformation Modes for Vascular Interventional Navigation Surgery",
     "year": 2023,
     "venue": "Actuators"
    },
    {
     "key": "alekseeva2025_design",
     "doi": "10.1002/rob.22480",
     "url": null,
     "title": "The Design of Endovascular Robots for Cardiac Interventions: A Survey",
     "year": 2024,
     "venue": "Journal of Field Robotics"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full",
   "notes": "N3 2026-11-08, from review_comparison Sec. 1.3 (Alekseeva Table 15 row 2). In scope as magnetic navigation: a computer-controlled 'three-dimensional electromagnet platform' bends the tip inside vessel models with a measured result. Number of coils, currents and workspace of the platform N.R. The permanent magnet of Fig. 5 was 'held in the operator's hands or installed on a robot arm' (Sec. 4); which one N.R.",
   "maintainers_own": false,
   "found_by": "actuated-tip"
  },
  {
   "schema_version": 1,
   "id": "vascure_zhao2021",
   "name": "CASIA VasCure",
   "full_name": "CASIA vascular robotic system: Dual-finger Robotic Hand (DRH) and VasCure two-channel PCI robot",
   "group": "Institute of Automation, Chinese Academy of Sciences (CASIA), State Key Lab of Management and Control for Complex Systems / Multimodal AI Systems (Zeng-Guang Hou, Xiao-Liang Xie, Xiao-Hu Zhou, Shi-Qi Liu, Gui-Bin Bian); animal tests at Shanghai Huadong Hospital",
   "group_short": "CASIA",
   "family": "academic",
   "category": "academic",
   "first_year": 2011,
   "latest_year": 2025,
   "versions": "2011 image-based guidewire navigation and delivery system (ji2011_guidewire, title); 2013 enhanced dual-finger robotic hand for catheter (bian2013_enhanced, title); 2015 dual-finger robotic hand (DRH): bionic thumb (driven roller, 2 DOF) and bionic forefinger (passive roller, 3 DOF); rotating the rollers about their axes advances the device, translating them in opposite directions along their axes rolls it; two steppers, guidewire gripper, console with handle and LCD panel; bench tests with EM tracking (feng2015_bioinspired, full: Sec. II-A, II-B, III); motion-scaling control (feng2015_motion abstract); 2020 Dual-finger Robotic Hand for Angioplasty, DRH: bionic thumb + bionic forefinger rollers on two steppers, DC-motor clamping, guidewire gripper (wei2020_novel Sec. 2, full); 2021 VasCure: one active + two passive rollers = two channels for two guidewires, graspers A/B, slave on a robot arm (zhao2021_vascure Sec. II, full) and 5G version with generalized predictive control (zhang2021_improved, abstract); 2023-2025 same platform in a white/blue housing on an arm used for learning-based delivery (li2024_modelbased Fig. 2; li2023_casog; li2023_discrete; wang2025_fuzzy); VasCure",
   "target_anatomy": "coronary (PCI; bifurcation lesions with two-stent technique)",
   "devices": [
    "guidewire",
    "catheter",
    "therapeutic-device"
   ],
   "devices_driven": "guidewire (two guidewires in VasCure) and balloon/stent catheter; master has separate catheter and balloon joysticks; guide catheter advanced manually by the assistant in the pig test (zhao2021_vascure Sec. II-A, III-B)",
   "n_dof": null,
   "n_dof_detail": "N.R. as a total; per channel guidewire translation + rotation (zhao2021_vascure Sec. II-B) 2015 DRH: thumb 2 DOF + forefinger 3 DOF (feng2015 Sec. II-A).",
   "translation_mechanism": "friction-roller",
   "translation_detail": "friction-roller",
   "rotation_mechanism": "roller-rolling",
   "rotation_detail": "other: active and passive rollers translate along their own axes to roll the wire like thumb and forefinger (zhao2021_vascure Sec. II-B); A4/chen2026 review calls it a subjacent lifting mechanism",
   "device_range": "N.R. (DRH stated compatible with catheters and balloon/stent catheters of different diameters, wei2020_novel Sec. 2) 2015 tests: guidewire 0.35 mm (0.36 in Table I) and balloon/stent catheter 0.7 mm, displacement limited to 200 mm (feng2015 Sec. III-A, III-D).",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "proximal: guidewire friction force from motor torque via a T21WN torque sensor (li2024_modelbased Sec. IV-B); no integrated force feedback in VasCure per chen2026_teleoperation (review) 2015 DRH: none; a torque sensor is future work (feng2015 Sec. IV).",
   "haptics_leader": "no force feedback reported; master console = guidewire handle (push/pull + rotating knob), catheter joystick, balloon joystick, touchscreen GUI (zhao2021_vascure Fig. 3)",
   "imaging_compat": "X-ray fluoroscopy (DSA in pig PCI); EM tracking used for bench accuracy",
   "sterility": "N.R.",
   "highest_validation": "animal",
   "validation_detail": "Remote pig PCI over a 5G commercial network, surgeon about 10 km away, two guidewires to LCX and LAD then balloons along both (zhao2021_vascure Sec. III-B; one pig described); GPC controller PCI on an experimental pig, IAE reduced by at least 20% (zhang2021_improved, abstract); further 5G remote PCI pig trials reported by a review (Han 2023 via chen2026_teleoperation [57], review-level)",
   "key_numbers": "VasCure max guidewire error 0.25 mm advance / 0.38 mm retract over 150 mm at 7.2-25.2 mm/s, 10 trials per speed per channel, EM tracker at 40 Hz (zhao2021_vascure Sec. III-A, Tables I-II); DRH mean axial RMSe 0.72 +/- 0.49 mm (wei2020_novel Abstract); review: 5G latency 90 -> 163 ms at 1100 km and 81 -> 161 ms at 18.3 km (chen2026_teleoperation, Han 2023); learning on the robot: CASOG 94.00 +/- 4.32% success (50 deliveries x 3 seeds; human demonstrations 39/42) on a 15 x 15 x 1 cm printed planar phantom (li2023_casog, arXiv HTML Table 2); CORVE 80.33 +/- 5.09% and 84.00 +/- 4.76% vs CASOG 69.67 +/- 2.69% on phantom 1 (li2024_modelbased Table II) 2015 DRH (feng2015 Sec. III): 5 trials per manipulation (guidewire and balloon/stent translation at 10 mm/s, guidewire rotation), speed sweeps 0.5-60 mm/s; RMS errors shown only as bar plots (Fig. 6), no number in the text.",
   "sim_model": "group's own guidewire/vessel VR simulators (fast and stable guidewire simulator EMBC 2015; elastic guidewire simulator wang2018_simulator; titles only); no model of the robot found",
   "has_sim_model": true,
   "sim2real": "none-found",
   "sim2real_detail": "none found: the RL controllers (CASOG, CORVE, discrete SAC, offline-online RL) were trained on data recorded on the physical robot over a planar phantom with an overhead 140 x 140 px camera, not in simulation (li2024_modelbased Sec. III-A, full; li2023_casog Sec. IV, arXiv HTML); li2023_discrete (Robotica 2023, full): DSAC-AE learned guidewire delivery directly on the 2-DOF robot over a 15 x 15 x 1.5 cm 3D-printed planar model, 140 x 140 px overhead images, 10 discrete actions every 0.5 s, success after 50k real samples in < 15 h (Sec. 2.1, 4); the paper argues against training in simulation (Sec. 1)",
   "picture": {
    "status": "not-cleared",
    "grade": "A",
    "kind": "photo",
    "source": "wei2020_novel Fig. 1 (DRH; native embedded raster p. 3)",
    "source_url": "https://doi.org/10.1007/978-3-030-63833-7_61",
    "licence": "publisher copyright",
    "credit": "Wei et al., Neural Information Processing (2020), Fig. 1. publisher copyright.",
    "edits": "native extract; no crop; no edits; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "vascure_zhao2021_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "VasCure slave on its arm at the animal experiment site",
     "source_key": "zhao2021_vascure",
     "source": "Zhao et al., 2021 43rd Annual International Conference of the IEEE Engineering in Medicine &amp; Biology Society (EMBC) (2021), Fig. 9, p. 3",
     "source_url": "https://doi.org/10.1109/embc46164.2021.9629943",
     "where": "Fig. 9, p. 3",
     "licence": "publisher copyright"
    },
    {
     "id": "vascure_zhao2021_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "VasCure master console with two handles and touch screen",
     "source_key": "zhao2021_vascure",
     "source": "Zhao et al., 2021 43rd Annual International Conference of the IEEE Engineering in Medicine &amp; Biology Society (EMBC) (2021), Fig. 3, p. 2",
     "source_url": "https://doi.org/10.1109/embc46164.2021.9629943",
     "where": "Fig. 3, p. 2",
     "licence": "publisher copyright"
    },
    {
     "id": "vascure_zhao2021_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD of the two-channel delivery device",
     "source_key": "zhao2021_vascure",
     "source": "Zhao et al., 2021 43rd Annual International Conference of the IEEE Engineering in Medicine &amp; Biology Society (EMBC) (2021), Fig. 4, p. 2",
     "source_url": "https://doi.org/10.1109/embc46164.2021.9629943",
     "where": "Fig. 4, p. 2",
     "licence": "publisher copyright"
    },
    {
     "id": "vascure_zhao2021_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Dual-finger robotic hand beside the acrylic phantom table",
     "source_key": "wei2020_novel",
     "source": "Wei et al., Neural Information Processing (2020), Fig. 2, p. 4",
     "source_url": "https://doi.org/10.1007/978-3-030-63833-7_61",
     "where": "Fig. 2, p. 4",
     "licence": "publisher copyright"
    },
    {
     "id": "vascure_zhao2021_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Dual-finger robotic hand (DRH) with its transparent cover",
     "source_key": "feng2015_bioinspired",
     "source": "Feng et al., 2015 IEEE International Conference on Robotics and Automation (ICRA) (2015), Fig. 1(a), p. 2",
     "source_url": "https://doi.org/10.1109/icra.2015.7139944",
     "where": "Fig. 1(a), p. 2",
     "licence": "publisher copyright"
    },
    {
     "id": "vascure_zhao2021_06",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Master console of the DRH system with operating handle",
     "source_key": "feng2015_bioinspired",
     "source": "Feng et al., 2015 IEEE International Conference on Robotics and Automation (ICRA) (2015), Fig. 1(b), p. 2",
     "source_url": "https://doi.org/10.1109/icra.2015.7139944",
     "where": "Fig. 1(b), p. 2",
     "licence": "publisher copyright"
    },
    {
     "id": "vascure_zhao2021_07",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Pre-clinical setup: vascular simulator fed by the robot's delivery unit",
     "source_key": "li2024_modelbased",
     "source": "Li et al., IEEE Transactions on Medical Robotics and Bionics (2024), Fig. 2(a), p. 2",
     "source_url": "https://doi.org/10.1109/tmrb.2024.3407349",
     "where": "Fig. 2(a), p. 2",
     "licence": "publisher copyright"
    },
    {
     "id": "vascure_zhao2021_08",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Robot feeding a guidewire into the 3D-printed planar phantom used for on-robot RL",
     "source_key": "li2023_discrete",
     "source": "Li et al., Robotica (2022), Fig. 1(a), p. 1117",
     "source_url": "https://doi.org/10.1017/s0263574722001527",
     "where": "Fig. 1(a), p. 1117",
     "licence": "publisher copyright (Cambridge University Press)"
    }
   ],
   "sources": [
    {
     "key": "zhao2021_vascure",
     "doi": "10.1109/embc46164.2021.9629943",
     "url": null,
     "title": "Design and Performance Evaluation of a Novel Vascular Robotic System for Complex Percutaneous Coronary Interventions",
     "year": 2021,
     "venue": "2021 43rd Annual International Conference of the IEEE Engineering in Medicine &amp; Biology Society (EMBC)"
    },
    {
     "key": "wei2020_novel",
     "doi": "10.1007/978-3-030-63833-7_61",
     "url": null,
     "title": "A Novel Vascular Robotic System: Performance Evaluation",
     "year": 2020,
     "venue": "Neural Information Processing"
    },
    {
     "key": "zhang2021_improved",
     "doi": "10.1109/embc46164.2021.9630311",
     "url": null,
     "title": "An Improved Networked Predictive Controller for Vascular Robot Using 5G Networks",
     "year": 2021,
     "venue": "2021 43rd Annual International Conference of the IEEE Engineering in Medicine &amp; Biology Society (EMBC)"
    },
    {
     "key": "feng2015_bioinspired",
     "doi": "10.1109/icra.2015.7139944",
     "url": null,
     "title": "Design and evaluation of a bio-inspired robotic hand for percutaneous coronary intervention",
     "year": 2015,
     "venue": "2015 IEEE International Conference on Robotics and Automation (ICRA)"
    },
    {
     "key": "feng2015_motion",
     "doi": "10.1109/embc.2015.7319490",
     "url": null,
     "title": "Preliminary study for motion scaling based control in minimally invasive vascular interventional robot",
     "year": 2015,
     "venue": "2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)"
    },
    {
     "key": "bian2013_enhanced",
     "doi": "10.1109/icinfa.2013.6720323",
     "url": null,
     "title": "An enhanced dual-finger robotic Hand for Catheter manipulating in vascular intervention: A preliminary study",
     "year": 2013,
     "venue": "2013 IEEE International Conference on Information and Automation (ICIA)"
    },
    {
     "key": "ji2011_guidewire",
     "doi": "10.1109/coginf.2011.6016161",
     "url": null,
     "title": "Guidewire navigation and delivery system for robot-assisted cardiology interventions",
     "year": 2011,
     "venue": "IEEE 10th International Conference on Cognitive Informatics and Cognitive Computing (ICCI-CC′11)"
    },
    {
     "key": "li2023_casog",
     "doi": "10.1109/tie.2023.3310021",
     "url": null,
     "title": "CASOG: Conservative Actor–Critic With SmOoth Gradient for Skill Learning in Robot-Assisted Intervention",
     "year": 2024,
     "venue": "IEEE Transactions on Industrial Electronics"
    },
    {
     "key": "li2024_modelbased",
     "doi": "10.1109/tmrb.2024.3407349",
     "url": null,
     "title": "Model-Based Offline Reinforcement Learning for Autonomous Delivery of Guidewire",
     "year": 2024,
     "venue": "IEEE Transactions on Medical Robotics and Bionics"
    },
    {
     "key": "li2023_discrete",
     "doi": "10.1017/s0263574722001527",
     "url": null,
     "title": "Discrete soft actor-critic with auto-encoder on vascular robotic system",
     "year": 2022,
     "venue": "Robotica"
    },
    {
     "key": "wang2025_fuzzy",
     "doi": "10.1109/rcar65431.2025.11139655",
     "url": null,
     "title": "A Fuzzy-Logic-Based Method for Autonomous Guidewire Delivery",
     "year": 2025,
     "venue": "2025 IEEE International Conference on Real-time Computing and Robotics (RCAR)"
    },
    {
     "key": "wang2018_simulator",
     "doi": "10.1007/s11432-017-9476-y",
     "url": null,
     "title": "A simulator with an elastic guidewire and vascular system for minimally invasive vascular surgery",
     "year": 2018,
     "venue": "Science China Information Sciences"
    },
    {
     "key": "chen2026_teleoperation",
     "doi": "10.1109/TMRB.2026.3681030",
     "url": null,
     "title": "Remote Teleoperation of Endovascular Intervention Robots: A Systematic Review",
     "year": 2026,
     "venue": "IEEE Transactions on Medical Robotics and Bionics"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (zhao2021_vascure, wei2020_novel, li2024_modelbased); partial (li2023_casog arXiv HTML); abstract (zhang2021_improved, feng2015_motion); review (chen2026_teleoperation); full (feng2015_bioinspired, 2026-10-14); title (ji2011_guidewire, bian2013_enhanced, wang2025_fuzzy); full (li2023_discrete,, 2026-11-08)",
   "notes": "SAME ROBOT as A4 row vascure_unknown2021 (developer N.R. there): VasCure is CASIA's (zhao2021_vascure author list and Sec. I). Merge: keep this row's group/mechanism/numbers and A4's review-level 5G trial counts. The A4 'clinical-stage' label is not supported: no human study found. X-ray overlay in zhao2021 Fig. 10 reads 'SH WEICHUANG MEDICAL CO.' (meaning N.R.). | 2026-11-08 X3: li2023_discrete read in full; its Fig. 1(a) (robot beside the planar phantom) added to the gallery as _08; merged from vascure_unknown2021 (A4)",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "casiattvr_lin2024",
   "name": "CASIA TTVR robot",
   "full_name": "CASIA robotic transcatheter tricuspid valve replacement (TTVR) system",
   "group": "Shuangyi Wang group, CASIA / University of Chinese Academy of Sciences and CAS Centre for Artificial Intelligence and Robotics, Hong Kong Institute of Science & Innovation, with Zeng-Guang Hou and Xiao-Hu Zhou; clinical partner Kent Chak-Yu So (CUHK, Prince of Wales Hospital)",
   "group_short": "CASIA",
   "family": "academic",
   "category": "academic",
   "first_year": 2024,
   "latest_year": 2026,
   "versions": "2024 TTVR system: passive stabilizer, robotic drive, detachable delivery catheter, valve manipulation mechanism; RL + Monte Carlo probabilistic maps + human-robot co-piloted control (wang2024_robotic, arXiv abstract); 2025 model-free delivery with Data-Enabled Predictive Control (DeePC) on the same drive and the LuX-Valve Plus delivery system, a camera standing in for fluoroscopy over a printed heart phantom (lin2025_modelfree, full); 2026 patient-specific geometry-aware planning + numerical-Jacobian IK control (lin2026_autonomous, abstract); 2026 virtual-physical simulation platform (lin2026_robotic, full)",
   "target_anatomy": "right heart: tricuspid valve (transcatheter tricuspid valve replacement / intervention)",
   "devices": [
    "catheter",
    "therapeutic-device"
   ],
   "devices_driven": "large-bore steerable TTVR delivery catheter (detachable) with valve Delivery system: LuX-Valve Plus (Jenscare Biotechnology, Ningbo) (lin2025 Sec. II).",
   "n_dof": 5,
   "n_dof_detail": "5 (overall forward/backward along the long axis, catheter rotation, outer-sheath advance/retract, bending of the bending tube, inner-core advance/retract; lin2025 Sec. II, Fig. 1(b)); 2 controlled (overall translation and bending; lin2025 Sec. III; lin2026_robotic Experimental setup)",
   "translation_mechanism": "other",
   "translation_detail": "other: robotic drive of the delivery-catheter system; overall translation by its own motor, drawn as a pinion on a toothed rack in lin2025 Fig. 1(b) (the text does not describe the mechanism)",
   "rotation_mechanism": "handle-rotation",
   "rotation_detail": "four motors in the drive unit, coupled through isolation parts to the instrument case that holds the delivery system (rotation, outer sheath, bending, inner core); \"The power from the Drive Unit is transmitted to the catheter through the Isolation Parts without direct physical contact\" (lin2025 Sec. II, Fig. 1(b))",
   "device_range": "workspace drawn in lin2025 Fig. 1(c): overall translation -28 to 212 mm, rotation -180 to 180 deg, outer sheath -107 to 20 mm, bending -90 to 0 deg, inner core -20 to 20 mm (graphic only, not in the text)",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "N.R.",
   "haptics_leader": "leader side with operator interface and GUI (lin2026_robotic Fig. 2b); haptics N.R.",
   "imaging_compat": "fluoroscopy (virtual fluoroscopy in the platform, 32 deg RAO / 7 deg CAU); optical shape/pose tracking of the catheter lin2025: a 640 x 480 px, 30 fps camera over the phantom stands in for fluoroscopy (Sec. IV-A).",
   "sterility": "components above the isolation parts can be sterilised during surgery (lin2025 Sec. II: \"the ability to sterilize the components above the Isolation Parts during surgery, while maintaining a sterile environment for the catheter\")",
   "highest_validation": "animal",
   "validation_detail": "first-in-vivo animal study (species and number N.R. in the arXiv abstract; full text not read); 15 patient CT datasets + 3 cardiac phantoms with mm-scale tip tracking error (lin2026_autonomous abstract); 10 operators raw vs augmented virtual fluoroscopy and 10 closed-loop control trials on the virtual-physical platform (lin2026_robotic) lin2025: printed patient-CT heart phantom (SVC, RA, RV); 3 catheters x 3 random start positions and 3 camera poses x 3 runs (Sec. IV-A, IV-C, Tables I-II); still phantom level.",
   "key_numbers": "co-piloted control better than master-slave in time efficiency, control efficiency, autonomy and stability (numbers N.R. in abstract); platform: tracking-to-CT registration 0.59 +/- 0.16 mm, landmark projection 2.31 +/- 0.60 px, input-to-display latency 255.6 +/- 13.4 ms, 2D angular error 15.02 -> 2.57 deg (median) with augmented fluoroscopy across 10 operators (lin2026_robotic Tables 1-2) lin2025 DeePC: \"In most cases, the final error in slope is less than 1 deg and the error in intercept is under 3 pixels\" for the tip line in the camera image (Sec. IV-C); worst case 2.55 +/- 0.04 deg and 3.37 +/- 0.17 px (camera pose 3, position 2, Table II); no success rate or time reported.",
   "sim_model": "virtual-physical simulator: real robot-driven catheter, optical shape tracking, CT-derived virtual fluoroscopy in 3D Slicer 5.10 (lin2026_robotic)",
   "has_sim_model": true,
   "sim2real": "unclear",
   "sim2real_detail": "RL is part of the 2024 system (wang2024_robotic abstract); where it was trained is N.R. (arXiv PDF not read). lin2025_modelfree (full): DeePC uses a Hankel matrix of the operator's recorded master-slave motion and \"does not require additional calibration or model training\" (Sec. III-A, V); no simulator.",
   "picture": {
    "status": "not-cleared",
    "grade": "A",
    "kind": "photo",
    "source": "lin2026_autonomous Fig. 6(a) (experimental set-up, p. 9), IEEE TBME 2026,",
    "source_url": "https://doi.org/10.1109/tbme.2026.3725663",
    "licence": "publisher copyright (IEEE)",
    "credit": "Lin et al., IEEE Transactions on Biomedical Engineering (2026), Fig. 6(a). publisher copyright (IEEE).",
    "edits": "native extract: the photo is embedded as three 3302 px raster strips (p9_9, p9_7, p9_12; the labels and arrows are vector text, not in the raster); stitched without overlap to 3302 x 689; cropped to the robot (left 44.5 %, phantom and holders cut); nothing erased; none upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "casiattvr_lin2024_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Driving system with delivery catheter, camera measuring system and heart phantom",
     "source_key": "lin2025_modelfree",
     "source": "Lin et al., 2025 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (2025), Fig. 5, p. 4",
     "source_url": "https://doi.org/10.1109/iros60139.2025.11247226",
     "where": "Fig. 5, p. 4",
     "licence": "publisher copyright"
    },
    {
     "id": "casiattvr_lin2024_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Drive unit: instrument case, motors, isolation parts and controller",
     "source_key": "lin2025_modelfree",
     "source": "Lin et al., 2025 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (2025), Fig. 1(b), p. 2",
     "source_url": "https://doi.org/10.1109/iros60139.2025.11247226",
     "where": "Fig. 1(b), p. 2",
     "licence": "publisher copyright"
    },
    {
     "id": "casiattvr_lin2024_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Robotic drive holding the LuX-Valve delivery catheter",
     "source_key": "lin2025_modelfree",
     "source": "Lin et al., 2025 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (2025), Fig. 1(a), p. 2",
     "source_url": "https://doi.org/10.1109/iros60139.2025.11247226",
     "where": "Fig. 1(a), p. 2",
     "licence": "publisher copyright"
    },
    {
     "id": "casiattvr_lin2024_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Delivery catheter in the instrument case with drive, valve-rotation and translation modules",
     "source_key": "lin2026_autonomous",
     "source": "Lin et al., IEEE Transactions on Biomedical Engineering (2026), Fig. 2, p. 6",
     "source_url": "https://doi.org/10.1109/tbme.2026.3725663",
     "where": "Fig. 2, p. 6",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "wang2024_robotic",
     "doi": "10.48550/ARXIV.2411.12478",
     "url": null,
     "title": "Robotic transcatheter tricuspid valve replacement with hybrid enhanced intelligence: a new paradigm and first-in-vivo study",
     "year": 2024,
     "venue": "arXiv"
    },
    {
     "key": "lin2025_modelfree",
     "doi": "10.1109/iros60139.2025.11247226",
     "url": null,
     "title": "Model-Free Catheter Delivery Strategy for Robotic Transcatheter Tricuspid Valve Replacement",
     "year": 2025,
     "venue": "2025 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS)"
    },
    {
     "key": "lin2026_autonomous",
     "doi": "10.1109/tbme.2026.3725663",
     "url": null,
     "title": "Autonomous Patient-Specific Geometry-Aware Planning and Control Framework for Robotic Transcatheter Tricuspid Valve Intervention",
     "year": 2026,
     "venue": "IEEE Transactions on Biomedical Engineering"
    },
    {
     "key": "lin2026_robotic",
     "doi": "10.1007/s11701-026-03852-1",
     "url": null,
     "title": "A robotic simulation platform for fluoroscopy-guided catheter navigation in transcatheter tricuspid valve intervention: system development and proof-of-concept applications",
     "year": 2026,
     "venue": "Journal of Robotic Surgery"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (lin2026_robotic); abstract (wang2024_robotic, lin2026_autonomous); full (lin2025_modelfree, 2026-10-14)",
   "notes": "Structural-heart catheter robot, not a guidewire/neuro robot; include or move to a structural-heart box.",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "beihang_wang2010",
   "name": "Beihang VIR",
   "full_name": "Beihang remote-controlled vascular interventional robot (VISR / VIR / RVIR / VIR-2) and its successor catheter operating robot (COR, 2016), the 2023 MIVI robot",
   "group": "Beihang University Robotics Institute (Tianmiao Wang, Da Liu; 2010 corresponding author Dapeng Zhang) and Image Processing Centre / School of Astronautics (Cai Meng); clinical: Department of Neurosurgery, Navy General Hospital of PLA (Wang-sheng Lu, Zeng-min Tian; author affiliation in lu2011 and lu2016); 2023 version Beijing Institute of Petrochemical Technology (Shaoya Guan, Limei Ma) with Cai Meng",
   "group_short": "Beihang U.",
   "family": "commercial",
   "category": "clinical-stage",
   "first_year": 2010,
   "latest_year": 2023,
   "versions": "2010 VISR: 5-DOF lockable passive hydraulic supporting arm + catheter navigator (rollers on a gear), PVDF tip sensor, Omega 6 master, glass model and 1 dog (wang2010_remote) -> 2011 VIR + virtual surgery training system, 10 beagles (lu2011_application) -> 2013 RVIR: image guidance (C-arm calibration, MicronTracker, catheter localisation, 3D reconstruction), Falcon master (meng2013_remote) -> VIR-2, 15 patients 2013 (lu2016_clinical, online 2015) -> 2016 COR, a new driver with bionic friction fingers, leadscrew rotation and a clamping motor, 2.6 kg, bench and glass model (meng2016_novel) -> 2023 MIVI robot with EM-tracked navigation (guan2023_multi; its Fig. 5(b) is the same photograph as meng2016 Fig. 5)",
   "target_anatomy": "cerebral (angiography in patients); renal, cardiac chambers, cerebrovascular arteries in animals; aortic (2023 navigation: AAA, TAA, AD data)",
   "devices": [
    "guidewire",
    "catheter",
    "sheath"
   ],
   "devices_driven": "catheter only, one device: 1.5 mm catheters (wang2010_remote p. 200); 4F-6F (1.33-2.00 mm) single-bend catheters through a 6F sheath, guidewire not driven ('the medical robot controlled only the catheter', lu2011_application p. 363, 365); 5F single-curve catheter in patients (lu2016_clinical p. 133); COR: 4F catheter (meng2016_novel p. 307)",
   "n_dof": 2,
   "n_dof_detail": "2 active (axial: stepping motor 2; rotation: stepping motor 1) on a 5-DOF lockable passive hydraulic supporting arm (wang2010_remote p. 196); COR: translation, rotation and clamping motors (meng2016_novel p. 305)",
   "translation_mechanism": "friction-roller",
   "translation_detail": "friction-roller (catheter clamped by rollers 1 and 2 driven by stepping motor 2, wang2010_remote p. 196; COR / 2023 MIVI: bionic friction fingers, meng2016_novel p. 305, guan2023_multi Fig. 5a)",
   "rotation_mechanism": "other",
   "rotation_detail": "the roller pair sits on a passive gear turned by stepping motor 1 through an active gear (wang2010_remote p. 196); COR: the two bionic fingers translate in opposite directions via a two-direction leadscrew and belt (finger rolling) (meng2016_novel p. 305); 2023: rotation motor (guan2023_multi Fig. 5a)",
   "device_range": "catheter speed 10-25 mm/s (wang2010_remote p. 199; lu2011_application p. 364); stroke N.R.; COR 205 pulses per mm (meng2016_novel p. 307)",
   "footprint_mm": "N.R.",
   "mass_kg": "COR 2.6 kg, aluminium alloy and steel (meng2016_novel p. 309); VIR N.R.",
   "force_sensing": "PVDF piezoelectric film glued at the catheter tip, robot stalls above a threshold (wang2010_remote p. 198); lu2011 calls the force feedback virtual (p. 365); not used in the 15 patients (lu2016_clinical p. 136); COR none",
   "haptics_leader": "Omega 6 haptic device (Force Dimension) (wang2010_remote p. 198); 3-DOF Novint Falcon in a shielded cabinet (meng2013_remote p. 231); master controlled over LAN, device N.R. (lu2016_clinical p. 133)",
   "imaging_compat": "X-ray/DSA (GE LCV+ C-arm); RVIR image guidance with an H40 MicronTracker and C-arm calibration phantom (meng2013_remote p. 231-236); 2023: EM tracking + CTA-DSA 2D/3D registration",
   "sterility": "N.R.",
   "highest_validation": "human",
   "validation_detail": "15 patients (March-September 2013), robot-assisted cerebral angiography, femoral sheath placed by hand, no complications (lu2016_clinical p. 133-134); 10 beagles (16-20 kg), 9 targets including both carotid and both vertebral arteries, 5 repeats, no complications (lu2011_application p. 363; meng2013_remote '10 dogs'); 1 dog, 5 targets, and glass model with 10 repeats per speed (wang2010_remote); COR: bench (10 trials per length 10-50 mm, 10 rotations) and glass model (meng2016_novel); 2023 vascular model only (guan2023_multi)",
   "key_numbers": "remote positioning accuracy 1.05 +/- 0.28 mm; staff DSA exposure 0 min; procedure 25-41 min, mean 34.4 +/- 5.13 min (lu2016_clinical p. 134); catheter motion error < 0.5 mm in a glass model (wang2010_remote p. 199); distortion correction RMS 0.35 px, distance reconstruction RMS 0.53 mm (max 1.34 mm) (meng2013_remote); COR axial accuracy -0.04 to 0.34 mm, relative error within +-5% (meng2016_novel Table I); 2023: 2D/3D registration < 1 mm, EM positioning RMS < 1 mm and max < 2 mm over 4 paths x 26 points (guan2023_multi Results, Fig. 7)",
   "sim_model": "virtual surgery training system (lu2011_application abstract); no controller-training model",
   "has_sim_model": true,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "photo",
    "source": "lu2016_clinical Fig. 2 (slave component of the propulsion system of the VIR-2 robot used in the 15-patient series), Int J Med Robot 2016;12:132-136, p. 133,",
    "source_url": "https://doi.org/10.1002/rcs.1650",
    "licence": "publisher copyright (Wiley)",
    "credit": "Lu et al., The International Journal of Medical Robotics and Computer Assisted Surgery (2015), Fig. 2. publisher copyright (Wiley).",
    "edits": "native extract (953 x 693); 3-px white frame cropped; nothing erased; none upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "beihang_wang2010_01",
     "status": "cleared",
     "file": "pictures/extra/beihang_wang2010_01.jpg",
     "thumb": "pictures/thumbs/beihang_wang2010_01.jpg",
     "kind": "render",
     "caption": "CAD of the MIVI robot: bionic fingers, clamping and rotation motors",
     "source_key": "guan2023_multi",
     "source": "Guan et al., BMC Surgery (2023), Fig. 5(a), p. 4",
     "source_url": "https://doi.org/10.1186/s12893-023-01944-5",
     "where": "Fig. 5(a), p. 4",
     "licence": "CC BY 4.0"
    },
    {
     "id": "beihang_wang2010_02",
     "status": "cleared",
     "file": "pictures/extra/beihang_wang2010_02.jpg",
     "thumb": "pictures/thumbs/beihang_wang2010_02.jpg",
     "kind": "in-use",
     "caption": "Catheter navigated to four target positions in a bifurcation phantom",
     "source_key": "guan2023_multi",
     "source": "Guan et al., BMC Surgery (2023), Fig. 6, p. 4",
     "source_url": "https://doi.org/10.1186/s12893-023-01944-5",
     "where": "Fig. 6, p. 4",
     "licence": "CC BY 4.0"
    },
    {
     "id": "beihang_wang2010_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Supporting manipulator and catheter navigator at a glass vascular model under the C-arm",
     "source_key": "meng2013_remote",
     "source": "Meng et al., The International Journal of Medical Robotics and Computer Assisted Surgery (2013), Fig. 12, p. 238",
     "source_url": "https://doi.org/10.1002/rcs.1494",
     "where": "Fig. 12, p. 238",
     "licence": "publisher copyright"
    },
    {
     "id": "beihang_wang2010_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Robot beside a dog on the angiography table during the animal experiment",
     "source_key": "meng2013_remote",
     "source": "Meng et al., The International Journal of Medical Robotics and Computer Assisted Surgery (2013), Fig. 13, p. 238",
     "source_url": "https://doi.org/10.1002/rcs.1494",
     "where": "Fig. 13, p. 238",
     "licence": "publisher copyright"
    },
    {
     "id": "beihang_wang2010_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Clinical cerebral angiography: catheter fixed in the slave, bedside scene, operator at the master",
     "source_key": "lu2016_clinical",
     "source": "Lu et al., The International Journal of Medical Robotics and Computer Assisted Surgery (2015), Fig. 3(a-d), p. 134",
     "source_url": "https://doi.org/10.1002/rcs.1650",
     "where": "Fig. 3(a-d), p. 134",
     "licence": "publisher copyright"
    },
    {
     "id": "beihang_wang2010_06",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "RVIR master site (image guidance, remote control device) and slave site (labelled)",
     "source_key": "meng2013_remote",
     "source": "Meng et al., The International Journal of Medical Robotics and Computer Assisted Surgery (2013), Fig. 1, p. 232",
     "source_url": "https://doi.org/10.1002/rcs.1494",
     "where": "Fig. 1, p. 232",
     "licence": "publisher copyright"
    },
    {
     "id": "beihang_wang2010_07",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "2016 catheter operating robot (COR): prototype photo and CAD with bionic fingers",
     "source_key": "meng2016_novel",
     "source": "Meng et al., 2016 IEEE Workshop on Advanced Robotics and its Social Impacts (ARSO) (2016), Fig. 1(a-b), p. 305",
     "source_url": "https://doi.org/10.1109/arso.2016.7736300",
     "where": "Fig. 1(a-b), p. 305",
     "licence": "publisher copyright"
    },
    {
     "id": "beihang_wang2010_08",
     "status": "cleared",
     "file": "pictures/extra/beihang_wang2010_08.jpg",
     "thumb": "pictures/thumbs/beihang_wang2010_08.jpg",
     "kind": "close-up",
     "caption": "Bionic-finger catheter driver (COR / MIVI robot) during a rotation test",
     "source_key": "guan2023_multi",
     "source": "Guan et al., BMC Surgery (2023), Fig. 5(b), p. 4 (previous main picture; the same photo is meng2016_novel Fig. 5)",
     "source_url": "https://doi.org/10.1186/s12893-023-01944-5",
     "where": "Fig. 5(b), p. 4 (previous main picture; the same photo is meng2016_novel Fig. 5)",
     "licence": "CC BY 4.0"
    }
   ],
   "sources": [
    {
     "key": "wang2010_remote",
     "doi": "10.1002/rcs.306",
     "url": null,
     "title": "Remote‐controlled vascular interventional surgery robot",
     "year": 2010,
     "venue": "The International Journal of Medical Robotics and Computer Assisted Surgery"
    },
    {
     "key": "lu2011_application",
     "doi": "10.1002/rcs.406",
     "url": null,
     "title": "Application study of medical robots in vascular intervention",
     "year": 2011,
     "venue": "The International Journal of Medical Robotics and Computer Assisted Surgery"
    },
    {
     "key": "meng2013_remote",
     "doi": "10.1002/rcs.1494",
     "url": null,
     "title": "A remote‐controlled vascular interventional robot: system structure and image guidance",
     "year": 2013,
     "venue": "The International Journal of Medical Robotics and Computer Assisted Surgery"
    },
    {
     "key": "lu2016_clinical",
     "doi": "10.1002/rcs.1650",
     "url": null,
     "title": "Clinical application of a vascular interventional robot in cerebral angiography",
     "year": 2015,
     "venue": "The International Journal of Medical Robotics and Computer Assisted Surgery"
    },
    {
     "key": "meng2016_novel",
     "doi": "10.1109/arso.2016.7736300",
     "url": null,
     "title": "A novel catheter operating robot for vascular interventional surgery",
     "year": 2016,
     "venue": "2016 IEEE Workshop on Advanced Robotics and its Social Impacts (ARSO)"
    },
    {
     "key": "guan2023_multi",
     "doi": "10.1186/s12893-023-01944-5",
     "url": null,
     "title": "Multi-mode information fusion navigation system for robot-assisted vascular interventional surgery",
     "year": 2023,
     "venue": "BMC Surgery"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (wang2010_remote, lu2011_application, meng2013_remote, lu2016_clinical, meng2016_novel, guan2023_multi)",
   "notes": "Two hardware lines in one row: VISR/VIR/RVIR/VIR-2 (2010-2016, human) and the COR (2016) = 2023 MIVI robot (phantom). guan2023 Fig. 5(b) and meng2016 Fig. 5 are the same photograph (compared side by side by X2), so the MIVI robot is the COR; meng2016 calls the COR a new robot and cites wang2010 only as related work. | X2 2026-11-08: all five Beihang papers read in full; main picture now the VIR-2 drive (lu2016 Fig. 2).",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "hit_fu2011",
   "name": "HIT catheter robot",
   "full_name": "HIT master-slave robotic catheter system for a steerable pull-wire catheter",
   "group": "Harbin Institute of Technology, State Key Laboratory of Robotics and System (Yili Fu, Anzhu Gao, Hao Liu, Kai Li, Zhaoguang Liang) with Harbin Medical University",
   "group_short": "HIT",
   "family": "academic",
   "category": "academic",
   "first_year": 2011,
   "latest_year": 2011,
   "versions": "2008-2010 active/steerable catheter navigation studies (Fu et al., IJMRCAS 2008-2009, titles); 2011 robotic catheter system (fu2011_development, full); 2011 master-slave catheterisation system (fu2011_masterslave, title)",
   "target_anatomy": "thoracic/cardiac vessels (thorax vascular phantom, brachiocephalic trunk)",
   "devices": [
    "catheter"
   ],
   "devices_driven": "custom 7 Fr single-curve pull-wire steerable catheter with two 5-DOF magnetic tracking sensors, two electrodes and a thermocouple (fu2011_development Sec. III)",
   "n_dof": 3,
   "n_dof_detail": "3 (push/pull, rotate, bend; fu2011_development Sec. II-C)",
   "translation_mechanism": "friction-roller",
   "translation_detail": "friction-roller",
   "rotation_mechanism": "rotating-drive-unit",
   "rotation_detail": "other: both stepping motors at equal speed rotate the whole friction-wheel unit about the catheter (fu2011_development Sec. IV); bending by a lead-screw slide unit moving the handle sleeve",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "proximal: two force-sensing elements between the inner and outer wheel of the active friction wheel (fu2011_development Fig. 6)",
   "haptics_leader": "Novint Falcon 3-DOF handle with force feedback (fu2011_development Fig. 2)",
   "imaging_compat": "EM magnetic tracking + MR-derived 3D guiding image (20 slices); intended to reduce X-ray use",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "thorax vascular phantom (Shelley Medical), catheterisation to the brachiocephalic trunk (fu2011_development Sec. VI)",
   "key_numbers": "image-sensor registration error mean 0.19 mm, RMS 0.49 mm, SD 0.46 mm over 700 wall points (fu2011_development Sec. VI, Fig. 9)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "photo",
    "source": "fu2011_development Fig. 7 handle manipulation mechanism (native scan raster p. 3)",
    "source_url": "https://doi.org/10.1109/iccme.2011.5876772",
    "licence": "publisher copyright",
    "credit": "Fu et al., The 2011 IEEE/ICME International Conference on Complex Medical Engineering (2011), Fig. 7. publisher copyright.",
    "edits": "native extract; cropped below baked-in text labels and above a blue arrow; two thin leader lines on the robot left; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "hit_fu2011_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Whole system: insertion and handle mechanisms, 3-DOF master handle, phantom",
     "source_key": "fu2011_development",
     "source": "Fu et al., The 2011 IEEE/ICME International Conference on Complex Medical Engineering (2011), Fig. 1, p. 2",
     "source_url": "https://doi.org/10.1109/iccme.2011.5876772",
     "where": "Fig. 1, p. 2",
     "licence": "publisher copyright"
    },
    {
     "id": "hit_fu2011_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Catheter insertion mechanism with friction wheels and stepping motors",
     "source_key": "fu2011_development",
     "source": "Fu et al., The 2011 IEEE/ICME International Conference on Complex Medical Engineering (2011), Fig. 5, p. 3",
     "source_url": "https://doi.org/10.1109/iccme.2011.5876772",
     "where": "Fig. 5, p. 3",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "fu2011_development",
     "doi": "10.1109/iccme.2011.5876772",
     "url": null,
     "title": "Development of a novel robotic catheter system for endovascular minimally invasive surgery",
     "year": 2011,
     "venue": "The 2011 IEEE/ICME International Conference on Complex Medical Engineering"
    },
    {
     "key": "fu2011_masterslave",
     "doi": "10.1504/ijma.2011.045271",
     "url": null,
     "title": "The master-slave catheterisation system for positioning the steerable catheter",
     "year": 2011,
     "venue": "International Journal of Mechatronics and Automation"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (fu2011_development, OCR of a scanned PDF); title (fu2011_masterslave)",
   "notes": "Anzhu Gao later moved to SJTU (row sjtumr_huang2022). The full-system photo (Fig. 1) and insertion mechanism (Fig. 5) carry baked-in labels.",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "sia_zhang2025",
   "name": "SIA finger-twist robot",
   "full_name": "SIA master-slave vascular interventional robot with bionic finger-twisting guidewire mechanism",
   "group": "Shenyang Institute of Automation, CAS, State Key Laboratory of Robotics (Hao Liu, Tianyu Zhang, Peng Lin, Liming Zheng, Xiao He) with General Hospital of Northern Theater Command (Ximei Zhao, Jing Qiu); 2022 leader device with Shenyang Jianzhu University",
   "group_short": "SIA (CAS)",
   "family": "academic",
   "category": "academic",
   "first_year": 2022,
   "latest_year": 2025,
   "versions": "2022 master manipulator with force feedback (li2022_design, title/affiliations); 2025 slave with bionic finger twisting mechanism + force-based occlusion detection (zhang2025_obstruction, full); 2024: SIA (Hao Liu, Peng Lin) flexible-belt constrained catheterization robot: guidewire in a lumen of two magnet-joined belts pulled by friction rollers, rear-end clamp twists, bench delivery error <= 1.5 mm at 75-125 mm belt spacing (Tian 2024 ICMA; Alekseeva 2025 Table 10 row 4, Fig. 11e) (tian2024_flexbelt; alekseeva2025_design); 2017: SIA (A. Gao, H. Liu) with the General Hospital of Shenyang Command, contact-aided asymmetric tendon-driven ablation catheter (2.6 mm): tendons pulled by a motorised lead screw for the bench bending tests, left-atrium phantom reached by manual tendon, rotation and insertion (Gao 2017 RA-L) (Alekseeva 2025 Table 14 row 7) (gao2017_contactaided; alekseeva2025_design)",
   "target_anatomy": "N.R. (vascular model with 4 branch regions)",
   "devices": [
    "guidewire",
    "catheter",
    "therapeutic-device"
   ],
   "devices_driven": "guidewire (twisted and advanced) and catheter (clamped by a solenoid valve) (zhang2025_obstruction Sec. IV-A)",
   "n_dof": 2,
   "n_dof_detail": "2 (axial delivery + rotation; displacement and rotation-angle mapping, zhang2025_obstruction Sec. III)",
   "translation_mechanism": "linear-stage+clamp",
   "translation_detail": "linear-stage+clamp",
   "rotation_mechanism": "roller-rolling",
   "rotation_detail": "other: bionic finger twisting mechanism",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "proximal: two force sensors on the twisting mechanism for axial force and radial torque (zhang2025_obstruction Sec. II-A)",
   "haptics_leader": "master handle with two motors and high-precision encoders rendering axial force and radial torque (zhang2025_obstruction Sec. II-A)",
   "imaging_compat": "N.R.",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "40 interventions in a vascular model; occlusion detected in 36 (zhang2025_obstruction Sec. IV-B)",
   "key_numbers": "occlusion detection 90% (36/40); axial force RMSE 414.15 mN; radial torque error 1.01 N·m as printed (torque traces are in mN·m); sampling 1 kHz (zhang2025_obstruction Abstract, Sec. IV-A)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "photo",
    "source": "zhang2025_obstruction Fig. 5 experimental platform (native raster p. 5)",
    "source_url": "https://doi.org/10.1109/rcar65431.2025.11139717",
    "licence": "publisher copyright",
    "credit": "Zhang et al., 2025 IEEE International Conference on Real-time Computing and Robotics (RCAR) (2025), Fig. 5. publisher copyright.",
    "edits": "native extract; cropped above red text labels; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "sia_zhang2025_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Master-slave test platform: slave actuator, PC and Geomagic Touch handle",
     "source_key": "li2022_design",
     "source": "Li et al., 2022 IEEE International Conference on Robotics and Biomimetics (ROBIO) (2022), Figure 6(a), p. 4",
     "source_url": "https://doi.org/10.1109/robio55434.2022.10011933",
     "where": "Figure 6(a), p. 4",
     "licence": "publisher copyright"
    },
    {
     "id": "sia_zhang2025_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Self-designed master manipulator: operation handle, timing belt, force sensor",
     "source_key": "li2022_design",
     "source": "Li et al., 2022 IEEE International Conference on Robotics and Biomimetics (ROBIO) (2022), Figure 6(b), p. 4",
     "source_url": "https://doi.org/10.1109/robio55434.2022.10011933",
     "where": "Figure 6(b), p. 4",
     "licence": "publisher copyright"
    },
    {
     "id": "sia_zhang2025_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Master manipulator on the force-feedback accuracy test bench",
     "source_key": "li2022_design",
     "source": "Li et al., 2022 IEEE International Conference on Robotics and Biomimetics (ROBIO) (2022), Figure 8, p. 5",
     "source_url": "https://doi.org/10.1109/robio55434.2022.10011933",
     "where": "Figure 8, p. 5",
     "licence": "publisher copyright"
    },
    {
     "id": "sia_zhang2025_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD of the master manipulator: spline shaft, handle, slip ring, motor",
     "source_key": "li2022_design",
     "source": "Li et al., 2022 IEEE International Conference on Robotics and Biomimetics (ROBIO) (2022), Figure 2(a), p. 2",
     "source_url": "https://doi.org/10.1109/robio55434.2022.10011933",
     "where": "Figure 2(a), p. 2",
     "licence": "publisher copyright"
    },
    {
     "id": "sia_zhang2025_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Radial torque feedback mechanism of the master manipulator",
     "source_key": "li2022_design",
     "source": "Li et al., 2022 IEEE International Conference on Robotics and Biomimetics (ROBIO) (2022), Figure 5(b), p. 4",
     "source_url": "https://doi.org/10.1109/robio55434.2022.10011933",
     "where": "Figure 5(b), p. 4",
     "licence": "publisher copyright"
    },
    {
     "id": "sia_zhang2025_06",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "Tian 2024 flexible-belt robot",
     "source_key": "tian2024_flexbelt",
     "source": "Tian et al., 2024 IEEE International Conference on Mechatronics and Automation (ICMA) (2024), tian2024_flexbelt Fig. 8 physical model of the catheterization robot, p. 5",
     "source_url": "https://doi.org/10.1109/ICMA61710.2024.10633087",
     "where": "tian2024_flexbelt Fig. 8 physical model of the catheterization robot, p. 5",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "sia_zhang2025_07",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Tian 2024 flexible-belt robot: Experimental scene: robot, monitor and control electronics on an optical table",
     "source_key": "tian2024_flexbelt",
     "source": "Tian et al., 2024 IEEE International Conference on Mechatronics and Automation (ICMA) (2024), Fig. 10, p. 5",
     "source_url": "https://doi.org/10.1109/ICMA61710.2024.10633087",
     "where": "Fig. 10, p. 5",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "sia_zhang2025_08",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Tian 2024 flexible-belt robot: CAD overview of the delivery and twisting mechanisms (labelled)",
     "source_key": "tian2024_flexbelt",
     "source": "Tian et al., 2024 IEEE International Conference on Mechatronics and Automation (ICMA) (2024), Fig. 2, p. 2",
     "source_url": "https://doi.org/10.1109/ICMA61710.2024.10633087",
     "where": "Fig. 2, p. 2",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "sia_zhang2025_09",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Tian 2024 flexible-belt robot: Top-view CAD of belts, support block, roller set and clamps (labelled)",
     "source_key": "tian2024_flexbelt",
     "source": "Tian et al., 2024 IEEE International Conference on Mechatronics and Automation (ICMA) (2024), Fig. 3(b), p. 3",
     "source_url": "https://doi.org/10.1109/ICMA61710.2024.10633087",
     "where": "Fig. 3(b), p. 3",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "sia_zhang2025_10",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Tian 2024 flexible-belt robot: CAD of the twisting mechanism with drive gear and rear-end clamp",
     "source_key": "tian2024_flexbelt",
     "source": "Tian et al., 2024 IEEE International Conference on Mechatronics and Automation (ICMA) (2024), Fig. 7, p. 4",
     "source_url": "https://doi.org/10.1109/ICMA61710.2024.10633087",
     "where": "Fig. 7, p. 4",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "sia_zhang2025_11",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Tian 2024 flexible-belt robot: Two flexible belts joined by magnets to form the device lumen",
     "source_key": "tian2024_flexbelt",
     "source": "Tian et al., 2024 IEEE International Conference on Mechatronics and Automation (ICMA) (2024), Fig. 1, p. 2",
     "source_url": "https://doi.org/10.1109/ICMA61710.2024.10633087",
     "where": "Fig. 1, p. 2",
     "licence": "publisher copyright (IEEE)"
    }
   ],
   "sources": [
    {
     "key": "zhang2025_obstruction",
     "doi": "10.1109/rcar65431.2025.11139717",
     "url": null,
     "title": "Obstruction Detection for Robotic Assisted Vascular Intervention",
     "year": 2025,
     "venue": "2025 IEEE International Conference on Real-time Computing and Robotics (RCAR)"
    },
    {
     "key": "li2022_design",
     "doi": "10.1109/robio55434.2022.10011933",
     "url": null,
     "title": "Design and experimental verification of a novel master manipulator with force feedback for vascular interventional robot",
     "year": 2022,
     "venue": "2022 IEEE International Conference on Robotics and Biomimetics (ROBIO)"
    },
    {
     "key": "tian2024_flexbelt",
     "doi": "10.1109/ICMA61710.2024.10633087",
     "url": null,
     "title": "Flexible Belt Constrained Catheterization Robot",
     "year": 2024,
     "venue": "2024 IEEE International Conference on Mechatronics and Automation (ICMA)"
    },
    {
     "key": "alekseeva2025_design",
     "doi": "10.1002/rob.22480",
     "url": null,
     "title": "The Design of Endovascular Robots for Cardiac Interventions: A Survey",
     "year": 2024,
     "venue": "Journal of Field Robotics"
    },
    {
     "key": "gao2017_contactaided",
     "doi": "10.1109/lra.2017.2676351",
     "url": null,
     "title": "A Contact-Aided Asymmetric Steerable Catheter for Atrial Fibrillation Ablation",
     "year": 2017,
     "venue": "IEEE Robotics and Automation Letters"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (zhang2025_obstruction); title/affiliations (li2022_design)",
   "notes": "Bench photo of a lab prototype; no product-like housing.",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "tju_he2018",
   "name": "TJU linear-stepping",
   "full_name": "Tianjin University linear-stepping endovascular robot with variable-stiffness SMP catheter and FBG tip-force sensing",
   "group": "Tianjin University, Key Laboratory of Mechanism Theory and Equipment Design (Chengbin He, Shuxin Wang, Siyang Zuo)",
   "group_short": "Tianjin U.",
   "family": "academic",
   "category": "academic",
   "first_year": 2018,
   "latest_year": 2018,
   "versions": "single version (he2018_linear)",
   "target_anatomy": "aortic arch phantom (ascending/descending aorta)",
   "devices": [
    "catheter",
    "sheath"
   ],
   "devices_driven": "custom catheter: shape-memory-polymer tube 2.5 mm OD / 1.0 mm ID with water cooling, silicone outer sheath 5 mm x 90 mm, four FBG fibres at the tip (he2018_linear Sec. Methods)",
   "n_dof": 2,
   "n_dof_detail": "2 (linear + rotation)",
   "translation_mechanism": "clamp-relay",
   "translation_detail": "clamp-relay",
   "rotation_mechanism": "rotating-clamp",
   "rotation_detail": "brushless DC servomotor (Faulhaber 1226S012B) turns the travel clutch on a gear pair through a conducting rotation ring (he2018_linear Sec. Linear stepping actuation unit)",
   "device_range": "the custom catheter above only",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "distal: four FBG sensors (0.16 mm) at the catheter tip with temperature compensation",
   "haptics_leader": "no (PC user interface)",
   "imaging_compat": "N.R.",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "vascular phantom insertion in rigid vs flexible state with tip-force monitoring (he2018_linear Fig. 11)",
   "key_numbers": "two electromagnet clutches (front + travel); Faulhaber LM1247-100-11 linear motor, max 100 mm per step; insertion 10 mm/s in the phantom test; SMP Tg 35 deg C; rigid catheter holds its shape against a 1.8 N·cm load (he2018_linear Abstract, Sec. Methods/Results)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "A",
    "kind": "photo",
    "source": "he2018_linear Fig. 2(b) prototype photo (native raster p. 4)",
    "source_url": "https://doi.org/10.1007/s11548-018-1722-x",
    "licence": "publisher copyright",
    "credit": "He et al., International Journal of Computer Assisted Radiology and Surgery (2018), Fig. 2(b). publisher copyright.",
    "edits": "native extract; cropped to panel (b) and above the '(b)' panel letter; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "tju_he2018_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Linear-stepping robot inserting the catheter into the aortic phantom",
     "source_key": "he2018_linear",
     "source": "He et al., International Journal of Computer Assisted Radiology and Surgery (2018), Fig. 11(a), p. 10",
     "source_url": "https://doi.org/10.1007/s11548-018-1722-x",
     "where": "Fig. 11(a), p. 10",
     "licence": "publisher copyright"
    },
    {
     "id": "tju_he2018_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Configuration of the linear stepping actuation unit",
     "source_key": "he2018_linear",
     "source": "He et al., International Journal of Computer Assisted Radiology and Surgery (2018), Fig. 2(a), p. 4",
     "source_url": "https://doi.org/10.1007/s11548-018-1722-x",
     "where": "Fig. 2(a), p. 4",
     "licence": "publisher copyright"
    },
    {
     "id": "tju_he2018_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Variable-stiffness SMP catheter prototype with FBG fibres",
     "source_key": "he2018_linear",
     "source": "He et al., International Journal of Computer Assisted Radiology and Surgery (2018), Fig. 5(b), p. 6",
     "source_url": "https://doi.org/10.1007/s11548-018-1722-x",
     "where": "Fig. 5(b), p. 6",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "he2018_linear",
     "doi": "10.1007/s11548-018-1722-x",
     "url": null,
     "title": "A linear stepping endovascular intervention robot with variable stiffness and force sensing",
     "year": 2018,
     "venue": "International Journal of Computer Assisted Radiology and Surgery"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full",
   "notes": "Distinct from A2's tianjin_song2023 (Tianjin University of Technology). Robot and actuated catheter in one system; the bedside unit is a clamp-relay drive in the Nagoya 'propelling pencil' tradition (he2018_linear Introduction).",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "tut_ma2021",
   "name": "TUT catheter system",
   "full_name": "TUT catheter operating system with real-catheter master and clamp-relay slave",
   "group": "Tianjin University of Technology, Tianjin Key Laboratory for Control Theory & Applications in Complicated Industry Systems (Xu Ma), with Tianjin University of Technology and Education",
   "group_short": "Tianjin U. Tech.",
   "family": "academic",
   "category": "academic",
   "first_year": 2020,
   "latest_year": 2021,
   "versions": "2020 robotic catheter manipulation system with BP-neural-network PID (ma2020_development, title); 2021 new catheter operating system (ma2021_design)",
   "target_anatomy": "N.R.",
   "devices": [
    "catheter"
   ],
   "devices_driven": "catheter",
   "n_dof": 2,
   "n_dof_detail": "2 (axial + rotation frames)",
   "translation_mechanism": "clamp-relay",
   "translation_detail": "clamp-relay",
   "rotation_mechanism": "rotating-drive-unit",
   "rotation_detail": "rotating frame (drive N.R.)",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "proximal thrust measured during insertion; force sensor UNCSR and torque sensor OPT-563B listed (ma2021_design, PMC HTML)",
   "haptics_leader": "real catheter used as the input handle on a pulley; DC motor with encoder on the pulley gives force/torque feedback",
   "imaging_compat": "N.R.",
   "sterility": "N.R.",
   "highest_validation": "bench",
   "validation_detail": "simulation and axial-displacement bench tests only; no phantom or animal (ma2021_design)",
   "key_numbers": "axial stroke 300 mm, push/withdraw 30 mm/s; BP-PID max axial error < 1.5 mm, mean 0.48 mm; step-response overshoot 20% (PID) vs 12% (BP-PID) in simulation; Maxon EC32 axial motor; DSP TMS320F28335, serial 19200 baud (ma2021_design)",
   "sim_model": "none found (controller simulated as a mass-spring-damper only)",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "cleared",
    "grade": "C",
    "kind": "photo",
    "source": "ma2021_design Fig. 3 slave manipulator, https://cdn.ncbi.nlm.nih.gov/pmc/blobs/69b3/7861939/0d63d0cf83e2/ABB2021-8898311.003.jpg (page https://pmc.ncbi.nlm.nih.gov/articles/PMC7861939/)",
    "source_url": "https://doi.org/10.1155/2021/8898311",
    "licence": "CC BY (Creative Commons Attribution License, as stated)",
    "credit": "Ma et al., Applied Bionics and Biomechanics (2021), Fig. 3. CC BY (Creative Commons Attribution License, as stated).",
    "edits": "PMC image as served; no edits; not upscaled",
    "file": "pictures/tut_ma2021.jpg"
   },
   "pictures": [
    {
     "id": "tut_ma2021_01",
     "status": "cleared",
     "file": "pictures/extra/tut_ma2021_01.jpg",
     "thumb": "pictures/thumbs/tut_ma2021_01.jpg",
     "kind": "leader",
     "caption": "Master end manipulator: encoders on the catheter held by the surgeon",
     "source_key": "ma2021_design",
     "source": "Ma et al., Applied Bionics and Biomechanics (2021), Fig. 4 (PMC7861939 figure 004)",
     "source_url": "https://doi.org/10.1155/2021/8898311",
     "where": "Fig. 4 (PMC7861939 figure 004)",
     "licence": "CC BY (Creative Commons Attribution License, as stated)"
    },
    {
     "id": "tut_ma2021_02",
     "status": "cleared",
     "file": "pictures/extra/tut_ma2021_02.jpg",
     "thumb": "pictures/thumbs/tut_ma2021_02.jpg",
     "kind": "render",
     "caption": "Slave end console with two graspers, load cell and torque sensor",
     "source_key": "ma2021_design",
     "source": "Ma et al., Applied Bionics and Biomechanics (2021), Fig. 7 (PMC7861939 figure 007)",
     "source_url": "https://doi.org/10.1155/2021/8898311",
     "where": "Fig. 7 (PMC7861939 figure 007)",
     "licence": "CC BY (Creative Commons Attribution License, as stated)"
    },
    {
     "id": "tut_ma2021_03",
     "status": "cleared",
     "file": "pictures/extra/tut_ma2021_03.jpg",
     "thumb": "pictures/thumbs/tut_ma2021_03.jpg",
     "kind": "render",
     "caption": "Surgeon's console: hollow encoder, couplings and shaft holders",
     "source_key": "ma2021_design",
     "source": "Ma et al., Applied Bionics and Biomechanics (2021), Fig. 6 (PMC7861939 figure 006)",
     "source_url": "https://doi.org/10.1155/2021/8898311",
     "where": "Fig. 6 (PMC7861939 figure 006)",
     "licence": "CC BY (Creative Commons Attribution License, as stated)"
    },
    {
     "id": "tut_ma2021_04",
     "status": "cleared",
     "file": "pictures/extra/tut_ma2021_04.jpg",
     "thumb": "pictures/thumbs/tut_ma2021_04.jpg",
     "kind": "render",
     "caption": "2020 system: main end handle stage and slave end on its inclined stand",
     "source_key": "ma2020_development",
     "source": "Ma et al., Applied Bionics and Biomechanics (2020), Fig. 1 (PMC7775165 figure 001)",
     "source_url": "https://doi.org/10.1155/2020/8870106",
     "where": "Fig. 1 (PMC7775165 figure 001)",
     "licence": "CC BY (Creative Commons Attribution License, as stated)"
    },
    {
     "id": "tut_ma2021_05",
     "status": "cleared",
     "file": "pictures/extra/tut_ma2021_05.jpg",
     "thumb": "pictures/thumbs/tut_ma2021_05.jpg",
     "kind": "render",
     "caption": "Axial force measurement mechanism: catheter frame, clamp plate, load cell",
     "source_key": "ma2020_development",
     "source": "Ma et al., Applied Bionics and Biomechanics (2020), Fig. 4 (PMC7775165 figure 004)",
     "source_url": "https://doi.org/10.1155/2020/8870106",
     "where": "Fig. 4 (PMC7775165 figure 004)",
     "licence": "CC BY (Creative Commons Attribution License, as stated)"
    }
   ],
   "sources": [
    {
     "key": "ma2021_design",
     "doi": "10.1155/2021/8898311",
     "url": null,
     "title": "Design of a New Catheter Operating System for the Surgical Robot",
     "year": 2021,
     "venue": "Applied Bionics and Biomechanics"
    },
    {
     "key": "ma2020_development",
     "doi": "10.1155/2020/8870106",
     "url": null,
     "title": "Development of a Robotic Catheter Manipulation System Based on BP Neural Network PID Controller",
     "year": 2020,
     "venue": "Applied Bionics and Biomechanics"
    }
   ],
   "read_level": "partial",
   "read_level_detail": "partial (PMC full-text HTML read through WebFetch)",
   "notes": "Same Tianjin Key Lab (TUT) as A2's tianjin_song2023 but a different robot; lineage of Shuxiang Guo's Kagawa/BIT group.",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "xmu_mei2025",
   "name": "XMU wire robot",
   "full_name": "Xiamen University vascular interventional robot for sim-trained guidewire navigation",
   "group": "Xiamen University (Yang Zhao, Ziyang Mei, Dezhi Wu, Gang Liu) with Shuxiang Guo (SUSTech / BIT)",
   "group_short": "Xiamen U.",
   "family": "academic",
   "category": "academic",
   "first_year": 2024,
   "latest_year": 2026,
   "versions": "2024/2025 robot + Pymunk-trained RL agent (mei2025_transferring, full); same group and hardware table in FreezeSeg2RL (mei2025_freezeseg2rl) and EVEGARS (PRCV 2026, see A6 notes); 2020: Xiamen University (Y. Zhao) remote-controlled TACE robot with force sensing and bending feedback (Zhou, Mei, ... Zhao 2020, Micromachines 11:805) (Belikov 2024 Fig. 6 ZH2; Duan 2023 Table 1 row 13) (belikov2024_evolution; duan2023_progress; li2024_design; zhao2022_remote)",
   "target_anatomy": "coronary paths (virtual tasks built from DSA images); transparent ex vivo vessel model in a water tank",
   "devices": [
    "guidewire",
    "microcatheter"
   ],
   "devices_driven": "guidewire and microcatheter (mei2025_transferring Sec. IV-B)",
   "n_dof": 3,
   "n_dof_detail": "3 modules: guidewire delivery, guidewire rotation, microcatheter linear motion (mei2025_transferring Sec. IV-B)",
   "translation_mechanism": "friction-roller",
   "translation_detail": "friction-roller",
   "rotation_mechanism": "rotating-drive-unit",
   "rotation_detail": "other: rotating platform driven along the axis by the friction-wheel module (mei2025_transferring Sec. IV-B)",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "none reported",
   "haptics_leader": "none (discrete commands from agent or surgeon)",
   "imaging_compat": "camera above a transparent model (no X-ray)",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "transparent vessel model ('ex vivo vascular model'), 4 targets; RL agent 40 deliveries per target, interventional surgeon 20 per target, replayed expert sequence as control (mei2025_transferring Sec. IV-B, Table III)",
   "key_numbers": "RL success 82.50 / 87.50 / 82.50 / 72.50% (targets A-D) vs surgeon 100% and expert-clone replay 0%; mean steps 41.61 / 36.8 / 45.94 / 54.10 vs 31 / 26.95 / 34.05 / 41.65; actions push/pull 10 mm, rotate 45 deg, wait 0.5 s (Tables II-III); simulation success 99.30 / 99.26 / 98.34% over three training stages (Sec. IV-A); HX8-U28 bus servos for friction wheels, ASM34AK steppers, ESP32 control",
   "sim_model": "2D Pymunk guidewire-vessel simulation built from DSA path reconstructions (mei2025_transferring Sec. III-A)",
   "has_sim_model": true,
   "sim2real": "yes",
   "sim2real_detail": "yes, phantom level: agent trained only in 2D simulation and run zero-shot on the robot with camera images re-rendered to the simulator style (mei2025_transferring Sec. IV-B, full)",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "photo",
    "source": "mei2025_transferring Fig. 1(c) robot cut-out by the authors (native raster p. 2)",
    "source_url": "https://doi.org/10.1109/tmech.2024.3420954",
    "licence": "publisher copyright",
    "credit": "Mei et al., IEEE/ASME Transactions on Mechatronics (2025), Fig. 1(c). publisher copyright.",
    "edits": "native extract; cropped; three annotation fragments (blue arrow, 'Delivery in Real-world' text, blue bar) on plain white background painted white, none touching the robot; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "xmu_mei2025_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Robot with micro-catheter and guidewire manipulators at the ex vivo model",
     "source_key": "mei2025_transferring",
     "source": "Mei et al., IEEE/ASME Transactions on Mechatronics (2025), Fig. 6, p. 7",
     "source_url": "https://doi.org/10.1109/tmech.2024.3420954",
     "where": "Fig. 6, p. 7",
     "licence": "publisher copyright"
    },
    {
     "id": "xmu_mei2025_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Guidewire robot under the X-ray probe with the remote station",
     "source_key": "mei2026_evegars",
     "source": "Mei et al., Lecture Notes in Computer Science (2026), Fig. 8, p. 12",
     "source_url": "https://doi.org/10.1007/978-981-95-5740-0_15",
     "where": "Fig. 8, p. 12",
     "licence": "publisher copyright"
    },
    {
     "id": "xmu_mei2025_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Robot at the end of the angiography table with the ex vivo vessel model",
     "source_key": "mei2025_freezeseg2rl",
     "source": "Mei et al., PRICAI 2025: Trends in Artificial Intelligence (2026), Fig. 8(a), p. 13",
     "source_url": "https://doi.org/10.1007/978-981-95-7072-0_25",
     "where": "Fig. 8(a), p. 13",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "mei2025_transferring",
     "doi": "10.1109/tmech.2024.3420954",
     "url": null,
     "title": "Transferring Virtual Surgical Skills to Reality: AI Agents Mastering Surgical Decision-Making in Vascular Interventional Robotics",
     "year": 2025,
     "venue": "IEEE/ASME Transactions on Mechatronics"
    },
    {
     "key": "mei2025_freezeseg2rl",
     "doi": "10.1007/978-981-95-7072-0_25",
     "url": null,
     "title": "FreezeSeg2RL: Frozen Segmentation Pretraining for Reinforcement Learning On Vascular Interventional Robot Autonomous Delivering",
     "year": 2026,
     "venue": "PRICAI 2025: Trends in Artificial Intelligence"
    },
    {
     "key": "belikov2024_evolution",
     "doi": "10.1016/j.jestch.2024.101789",
     "url": null,
     "title": "Evolution and current state of robotic catheters for endovascular surgery: A comprehensive review",
     "year": 2024,
     "venue": "Engineering Science and Technology, an International Journal"
    },
    {
     "key": "duan2023_progress",
     "doi": "10.3390/mi14010197",
     "url": null,
     "title": "Technical and Clinical Progress on Robot-Assisted Endovascular Interventions: A Review",
     "year": 2023,
     "venue": "Micromachines"
    },
    {
     "key": "li2024_design",
     "doi": "10.1109/tmrb.2024.3377374",
     "url": null,
     "title": "Robotic Systems Design in Endovascular Treatment",
     "year": 2024,
     "venue": "IEEE Transactions on Medical Robotics and Bionics"
    },
    {
     "key": "zhao2022_remote",
     "doi": "10.21037/qims-21-792",
     "url": null,
     "title": "Remote vascular interventional surgery robotics: a literature review",
     "year": 2022,
     "venue": "Quantitative Imaging in Medicine and Surgery"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full",
   "notes": "A6 lists the EVEGARS/FreezeSeg2RL sim2real rows on the same hardware; this TMECH paper is the one that describes the robot.",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "soochow_yang2023",
   "name": "Soochow robot",
   "full_name": "Soochow University interventional surgical robot with catheter-tip thin-film force sensing",
   "group": "Soochow University, School of Optoelectronic Science and Engineering (Wei Wei, Dong Yang) with Suzhou University of Science and Technology and BIT (Nan Xiao)",
   "group_short": "Soochow U.",
   "family": "academic",
   "category": "academic",
   "first_year": 2022,
   "latest_year": 2023,
   "versions": "2022 strain-gauge catheter bending recognition (wei2022_intravascular, abstract); 2022 vascular environment identification (yang2022_vascular, title); 2023 multi-data detection robot (yang2023_interventional, abstract + figures)",
   "target_anatomy": "N.R. (DSA of cerebral vessels shown in the system schematic)",
   "devices": [
    "guidewire",
    "catheter"
   ],
   "devices_driven": "catheter and guidewire (separate clamping modules, yang2023_interventional Fig. 2 labels)",
   "n_dof": null,
   "n_dof_detail": "N.R.",
   "translation_mechanism": "linear-stage+clamp",
   "translation_detail": "linear-stage+clamp",
   "rotation_mechanism": "not-reported",
   "rotation_detail": "N.R.",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "distal thin-film force sensor in the catheter head (insect-antenna inspired) + pressure sensor in the catheter clamping device (2023); strain gauges on the catheter (2022)",
   "haptics_leader": "master with two knobs and touchscreen (yang2023_interventional Fig. 1); force feedback N.R.",
   "imaging_compat": "N.R.",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "vessel-model tests for environment classification (counts N.R. in the abstracts)",
   "key_numbers": "LSTM vascular-environment classification accuracy 94.2% (yang2023_interventional abstract); GA-optimised BP network reduces bending-recognition error by 37% (wei2022_intravascular abstract); EtherCAT motion control (Fig. 1)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "cleared",
    "grade": "C",
    "kind": "photo",
    "source": "yang2023_interventional Fig. 1 right panel, https://mdpi-res.com/applsci/applsci-13-05301/article_deploy/html/images/applsci-13-05301-g001.png (page https://www.mdpi.com/2076-3417/13/9/5301)",
    "source_url": "https://doi.org/10.3390/app13095301",
    "licence": "CC BY 4.0",
    "credit": "Yang et al., Applied Sciences (2023), Fig. 1. CC BY 4.0.",
    "edits": "cropped to the slave photo; not upscaled",
    "file": "pictures/soochow_yang2023.jpg"
   },
   "pictures": [
    {
     "id": "soochow_yang2023_01",
     "status": "cleared",
     "file": "pictures/extra/soochow_yang2023_01.jpg",
     "thumb": "pictures/thumbs/soochow_yang2023_01.jpg",
     "kind": "photo",
     "caption": "Slave with DC motors, encoders, guidewire and catheter clamping modules",
     "source_key": "yang2023_interventional",
     "source": "Yang et al., Applied Sciences (2023), Fig. 2 (MDPI HTML figure g002)",
     "source_url": "https://doi.org/10.3390/app13095301",
     "where": "Fig. 2 (MDPI HTML figure g002)",
     "licence": "CC BY 4.0"
    },
    {
     "id": "soochow_yang2023_02",
     "status": "cleared",
     "file": "pictures/extra/soochow_yang2023_02.jpg",
     "thumb": "pictures/thumbs/soochow_yang2023_02.jpg",
     "kind": "photo",
     "caption": "Catheter manipulator and guidewire manipulator on the slave rail",
     "source_key": "wei2022_intravascular",
     "source": "Wei et al., Machines (2022), Fig. 2 (MDPI HTML figure g002)",
     "source_url": "https://doi.org/10.3390/machines10010042",
     "where": "Fig. 2 (MDPI HTML figure g002)",
     "licence": "CC BY 4.0"
    },
    {
     "id": "soochow_yang2023_03",
     "status": "cleared",
     "file": "pictures/extra/soochow_yang2023_03.jpg",
     "thumb": "pictures/thumbs/soochow_yang2023_03.jpg",
     "kind": "render",
     "caption": "CAD of the clamping module: gears, DC motor, sensor and steering engine",
     "source_key": "yang2023_interventional",
     "source": "Yang et al., Applied Sciences (2023), Fig. 3 (MDPI HTML figure g003)",
     "source_url": "https://doi.org/10.3390/app13095301",
     "where": "Fig. 3 (MDPI HTML figure g003)",
     "licence": "CC BY 4.0"
    },
    {
     "id": "soochow_yang2023_04",
     "status": "cleared",
     "file": "pictures/extra/soochow_yang2023_04.jpg",
     "thumb": "pictures/thumbs/soochow_yang2023_04.jpg",
     "kind": "close-up",
     "caption": "Force sensor mounted on the module slideway",
     "source_key": "yang2023_interventional",
     "source": "Yang et al., Applied Sciences (2023), Fig. 5 (MDPI HTML figure g005)",
     "source_url": "https://doi.org/10.3390/app13095301",
     "where": "Fig. 5 (MDPI HTML figure g005)",
     "licence": "CC BY 4.0"
    },
    {
     "id": "soochow_yang2023_05",
     "status": "cleared",
     "file": "pictures/extra/soochow_yang2023_05.jpg",
     "thumb": "pictures/thumbs/soochow_yang2023_05.jpg",
     "kind": "close-up",
     "caption": "Resistance sensing in the catheter module, CAD and photos",
     "source_key": "wei2022_intravascular",
     "source": "Wei et al., Machines (2022), Fig. 3 (MDPI HTML figure g003)",
     "source_url": "https://doi.org/10.3390/machines10010042",
     "where": "Fig. 3 (MDPI HTML figure g003)",
     "licence": "CC BY 4.0"
    },
    {
     "id": "soochow_yang2023_06",
     "status": "cleared",
     "file": "pictures/extra/soochow_yang2023_06.jpg",
     "thumb": "pictures/thumbs/soochow_yang2023_06.jpg",
     "kind": "render",
     "caption": "CAD of the force-sensing slideway under the clamping module",
     "source_key": "yang2023_interventional",
     "source": "Yang et al., Applied Sciences (2023), Fig. 4 (MDPI HTML figure g004)",
     "source_url": "https://doi.org/10.3390/app13095301",
     "where": "Fig. 4 (MDPI HTML figure g004)",
     "licence": "CC BY 4.0"
    },
    {
     "id": "soochow_yang2023_07",
     "status": "cleared",
     "file": "pictures/extra/soochow_yang2023_07.jpg",
     "thumb": "pictures/thumbs/soochow_yang2023_07.jpg",
     "kind": "close-up",
     "caption": "Catheter tip with thin-film strain gauges",
     "source_key": "wei2022_intravascular",
     "source": "Wei et al., Machines (2022), Fig. 8 (MDPI HTML figure g008)",
     "source_url": "https://doi.org/10.3390/machines10010042",
     "where": "Fig. 8 (MDPI HTML figure g008)",
     "licence": "CC BY 4.0"
    },
    {
     "id": "soochow_yang2023_08",
     "status": "cleared",
     "file": "pictures/extra/soochow_yang2023_08.jpg",
     "thumb": "pictures/thumbs/soochow_yang2023_08.jpg",
     "kind": "leader",
     "caption": "Master manipulator with two control knobs and touch screen",
     "source_key": "yang2023_interventional",
     "source": "Yang et al., Applied Sciences (2023), Fig. 1 (left part) (MDPI HTML figure g001)",
     "source_url": "https://doi.org/10.3390/app13095301",
     "where": "Fig. 1 (left part) (MDPI HTML figure g001)",
     "licence": "CC BY 4.0"
    }
   ],
   "sources": [
    {
     "key": "yang2023_interventional",
     "doi": "10.3390/app13095301",
     "url": null,
     "title": "An Interventional Surgical Robot Based on Multi-Data Detection",
     "year": 2023,
     "venue": "Applied Sciences"
    },
    {
     "key": "wei2022_intravascular",
     "doi": "10.3390/machines10010042",
     "url": null,
     "title": "An Intravascular Catheter Bending Recognition Method for Interventional Surgical Robots",
     "year": 2022,
     "venue": "Machines"
    },
    {
     "key": "yang2022_vascular",
     "doi": "10.1109/robio55434.2022.10011932",
     "url": null,
     "title": "Vascular Environment Identification Based on Multi-dimensional Data Fusion for Interventional Surgical Robots",
     "year": 2022,
     "venue": "2022 IEEE International Conference on Robotics and Biomimetics (ROBIO)"
    }
   ],
   "read_level": "abstract",
   "read_level_detail": "abstract + figures",
   "notes": "Sharper photo in Fig. 2 carries red leader lines ending on the robot.",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "sjtumr_huang2022",
   "name": "SJTU MR wire drive",
   "full_name": "SJTU pneumatic MR-conditional guidewire delivery mechanism with decoupled actuation",
   "group": "Shanghai Jiao Tong University, Institute of Medical Robotics (Anzhu Gao, Guang-Zhong Yang; Shaoping Huang) with Empa",
   "group_short": "SJTU",
   "family": "academic",
   "category": "academic",
   "first_year": 2022,
   "latest_year": 2022,
   "versions": "single version (huang2022_pneumatic)",
   "target_anatomy": "coronary (PCI) under MRI; aorta phantom",
   "devices": [
    "guidewire"
   ],
   "devices_driven": "guidewire",
   "n_dof": 2,
   "n_dof_detail": "2 (translation + rotation, decoupled)",
   "translation_mechanism": "friction-roller",
   "translation_detail": "friction-roller",
   "rotation_mechanism": "rotating-drive-unit",
   "rotation_detail": "other: pneumatic slip ring rotates the whole wheel unit, driven by a rotary pneumatic step motor through 1:5 spur gears",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "none",
   "haptics_leader": "handheld control (huang2022_pneumatic Fig. 4); haptics N.R.",
   "imaging_compat": "MR-conditional: pneumatic step motors, 3D-printed parts; tested in a Siemens MAGNETOM Aera 1.5 T",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "real-time MRI-guided guidewire delivery in an aorta phantom (TRANDOMED SJK001F) (huang2022_pneumatic Sec. IV-C)",
   "key_numbers": "resolution 0.238 mm/step and 0.4 deg/step; mean translational error 0.37 mm; rotary motor torque 15.75 N·m/MPa as printed; pneumatic clamp 9 mm bore, 63 N/MPa; SNR loss < 2% (huang2022_pneumatic Abstract, Sec. II-III)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "render",
    "source": "huang2022_pneumatic Fig. 1(a) (native raster p. 2)",
    "source_url": "https://doi.org/10.1109/iros47612.2022.9981596",
    "licence": "publisher copyright",
    "credit": "Huang et al., 2022 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (2022), Fig. 1(a). publisher copyright.",
    "edits": "native extract; 50 px white margin added; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "sjtumr_huang2022_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Pneumatic guidewire mechanism on the MRI table beside the aortic phantom",
     "source_key": "huang2022_pneumatic",
     "source": "Huang et al., 2022 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (2022), Fig. 4, p. 4",
     "source_url": "https://doi.org/10.1109/iros47612.2022.9981596",
     "where": "Fig. 4, p. 4",
     "licence": "publisher copyright"
    },
    {
     "id": "sjtumr_huang2022_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Design of the pneumatic rotary motor (MotorR)",
     "source_key": "huang2022_pneumatic",
     "source": "Huang et al., 2022 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (2022), Fig. 3, p. 3",
     "source_url": "https://doi.org/10.1109/iros47612.2022.9981596",
     "where": "Fig. 3, p. 3",
     "licence": "publisher copyright"
    },
    {
     "id": "sjtumr_huang2022_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Section views: wheel transfer, pneumatic clamp and slip ring",
     "source_key": "huang2022_pneumatic",
     "source": "Huang et al., 2022 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (2022), Fig. 1(b)-(d), p. 2",
     "source_url": "https://doi.org/10.1109/iros47612.2022.9981596",
     "where": "Fig. 1(b)-(d), p. 2",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "huang2022_pneumatic",
     "doi": "10.1109/iros47612.2022.9981596",
     "url": null,
     "title": "A Pneumatic MR-conditional Guidewire Delivery Mechanism with Decoupled Actuations for Endovascular Intervention",
     "year": 2022,
     "venue": "2022 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS)"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full",
   "notes": "Third SJTU robot in the catalogue (A2 has sjtu_xie_shen2019 and sjtu_coronary_meng2025); this one is MR-conditional. Photo in the MR room (Fig. 4) is 573 px.",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "ciomp_chen2025",
   "name": "CIOMP isomorphic",
   "full_name": "CIOMP leader-follower isomorphic vascular interventional surgical robot",
   "group": "Changchun Institute of Optics, Fine Mechanics and Physics, CAS, State Key Laboratory of Dynamic Optical Imaging and Measurement (Pengfei Chen, Yutang Wang, Dapeng Tian)",
   "group_short": "CIOMP (CAS)",
   "family": "academic",
   "category": "academic",
   "first_year": 2025,
   "latest_year": 2025,
   "versions": "single version (chen2025_design)",
   "target_anatomy": "human vascular model",
   "devices": [
    "guidewire",
    "catheter"
   ],
   "devices_driven": "catheter and guidewire (catheter delivery mechanism, catheter rotation mechanism, guidewire operation mechanism; chen2025_design Fig. 1 labels)",
   "n_dof": null,
   "n_dof_detail": "N.R. (catheter delivery + rotation, guidewire delivery + rotation shown)",
   "translation_mechanism": "other",
   "translation_detail": "other: catheter between upper and lower pressing plates with an electric clamp; guidewire via operating handle on a screw drive (Fig. 1 labels)",
   "rotation_mechanism": "other",
   "rotation_detail": "gear drive (driving/driven gears, rotating motor; Fig. 1 labels)",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "N.R. in abstract; force channels in the four-channel bilateral controller (Fig. 2)",
   "haptics_leader": "isomorphic leader with identical structure; four-channel acceleration-based bilateral control with DOB/RFOB (abstract, Fig. 2)",
   "imaging_compat": "N.R.",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "intervention task in a human vascular model with 4 volunteers; CUSUM learning curves (chen2025_design abstract, Fig. 7)",
   "key_numbers": "leader-follower delivery error < 1 mm, guidewire rotation error < 0.3 deg; operators mastered the task within 10 trials; operator-experience classification accuracy 94% (chen2025_design abstract)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "cleared",
    "grade": "B",
    "kind": "render",
    "source": "chen2025_design Fig. 1 centre panel, https://mdpi-res.com/actuators/actuators-14-00029/article_deploy/html/images/actuators-14-00029-g001.png (page https://www.mdpi.com/2076-0825/14/1/29)",
    "source_url": "https://doi.org/10.3390/act14010029",
    "licence": "CC BY 4.0",
    "credit": "Chen et al., Actuators (2025), Fig. 1. CC BY 4.0.",
    "edits": "cropped to the grey render panel; not upscaled",
    "file": "pictures/ciomp_chen2025.jpg"
   },
   "pictures": [
    {
     "id": "ciomp_chen2025_01",
     "status": "cleared",
     "file": "pictures/extra/ciomp_chen2025_01.jpg",
     "thumb": "pictures/thumbs/ciomp_chen2025_01.jpg",
     "kind": "setup",
     "caption": "Leader robot, follower robot, camera and IPC on the test bench",
     "source_key": "chen2025_design",
     "source": "Chen et al., Actuators (2025), Fig. 4(a) (MDPI HTML figure g004)",
     "source_url": "https://doi.org/10.3390/act14010029",
     "where": "Fig. 4(a) (MDPI HTML figure g004)",
     "licence": "CC BY 4.0"
    },
    {
     "id": "ciomp_chen2025_02",
     "status": "cleared",
     "file": "pictures/extra/ciomp_chen2025_02.jpg",
     "thumb": "pictures/thumbs/ciomp_chen2025_02.jpg",
     "kind": "render",
     "caption": "CAD close-ups: catheter delivery, catheter rotation and guidewire mechanisms",
     "source_key": "chen2025_design",
     "source": "Chen et al., Actuators (2025), Fig. 1 (bottom row) (MDPI HTML figure g001)",
     "source_url": "https://doi.org/10.3390/act14010029",
     "where": "Fig. 1 (bottom row) (MDPI HTML figure g001)",
     "licence": "CC BY 4.0"
    }
   ],
   "sources": [
    {
     "key": "chen2025_design",
     "doi": "10.3390/act14010029",
     "url": null,
     "title": "Design and Evaluation of a Leader–Follower Isomorphic Vascular Interventional Surgical Robot",
     "year": 2025,
     "venue": "Actuators"
    }
   ],
   "read_level": "abstract",
   "read_level_detail": "abstract + figures",
   "notes": "Not in any earlier list.",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "yanshan_yu2023",
   "name": "Wearable VIR",
   "full_name": "Yanshan University wearable vascular interventional surgical robot",
   "group": "Yanshan University, Hebei Provincial Key Laboratory of Parallel Robot and Mechatronic System (Haoyang Yu, Hongbo Wang, Jianye Niu) with Fudan University Academy for Engineering & Technology",
   "group_short": "Yanshan U.",
   "family": "academic",
   "category": "academic",
   "first_year": 2023,
   "latest_year": 2024,
   "versions": "2023 wearable system (yu2023_wearable; received 2023, IJMRCAS 2024;20(1):e2616); its fuzzy-PID position controller comes from the group's earlier robot Yu et al., Appl. Sci. 2021;11(2):611 (ref. 24, not read); the same group's 2023 complex-coronary robot is A2's yu_complexcoronary_2023; 2021: H. Yu / H. Wang (Yanshan) VIS robot with force feedback and flexible clamping (Yu 2021 Appl. Sci. 11:611) and precise-delivery VIS robot with an operating-sleeve leader (Wang 2021 IEEE Access), possibly one robot (Chen 2023 Figs. 6(d), 9(a); Duan 2023 Table 1 row 4) (chen2023_operating; duan2023_progress); 2018: H. Y. Yu / H. B. Wang (Yanshan) master-slave system: master with an operating sleeve that slides and turns on a shaft (ball and V-groove decoupling), two encoders and a magnetic-particle clutch for force feedback; wire feeder that clamps, pushes and twists the device with a fixed, a promoting and a rotating finger; five servo motors; bench: feedback torque of the clutch calibrated with weights from 0.05 to 1 N m, about linear in the clutch current (Yu 2018 RCAR, Secs. II, IV, Figs. 2, 6, 11); the group's 2011-2015 mechanisms (X. Yang, H. Wang; Zhao 2022 Table 1 row 8b, Belikov 2024 Fig. 6 YA) are earlier versions, not read (yu2018_master; zhao2022_remote; belikov2024_evolution)",
   "target_anatomy": "coronary (PCI): radial artery to the coronary arteries in a human vessel model, femoral access to the right coronary artery in a pig (yu2023_wearable Sec. 2.3.3-2.3.4)",
   "devices": [
    "guidewire",
    "catheter"
   ],
   "devices_driven": "one guidewire or one catheter at a time; catheter and guidewire cannot be driven together (Sec. 4). Animal study: Cordis ATW guidewire (ATW-595-ME014) through a manually placed MPA1 8F catheter (Sec. 2.3.4)",
   "n_dof": 3,
   "n_dof_detail": "3 device DOF: clamp, push/pull, twist (Sec. 2.1, Sec. 5); plus DM pitch set by a linear actuator and position on a lockable slideway of the wearable frame (Sec. 2.1.2, Fig. 6)",
   "translation_mechanism": "clamp-relay",
   "translation_detail": "clamp-relay: fixing module (F1, F2) holds the wire while the clamping module (C1, C2) on a screw-driven slider pushes, then they swap ('reciprocating delivery'; Sec. 2.1.2, Figs. 7-8); propulsion DC motor 26SYK55.24 (Sec. 2.2.1)",
   "rotation_mechanism": "rotating-clamp",
   "rotation_detail": "wedge-shaped gripper closed by a crank-rocker and spring, rotated with the clamped wire through a gear set by a Maxon RE13 motor (Sec. 2.1.2, Fig. 9)",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "slave: pressure sensor (SBT674-10 N) under the clamping module, a lever with arm ratio l1/l2 = 3 amplifies the delivery resistance 3x (Sec. 2.1.2, Fig. 10); master: torque sensor (DSN-206) in the handle drive (Sec. 2.2.1)",
   "haptics_leader": "custom 3-DOF handle (operating manipulator): slide and rotation read by encoders, three-button squeeze read by a thin-film sensor (Flexiforce) sets the clamp; a servo motor with torque sensor drags the handle, velocity-force mapping slows it as delivery resistance rises (Sec. 2.1.1, 2.2.2, Figs. 2-5, 14)",
   "imaging_compat": "used under a C-arm angiography system in the pig study (Sec. 2.3.4, Fig. 19); radiolucency N.R.",
   "sterility": "driven gear shaft and gripper held by a magnetic cover, removed and replaced after surgery for sterilisation (Sec. 2.1.2); drape N.R.",
   "highest_validation": "animal",
   "validation_detail": "bench: 5 push and 5 twist master-slave tracking runs, 5 force-feedback runs (Sec. 2.3.1-2.3.2); human vessel model: 4 untrained testers x 3 targets x 3 trials, all 12 target deliveries within 60 s by the 3rd trial (Table 1); animal: 1 Bama pig (SIAT), guidewire to the right coronary artery, 3 robotic vs 3 manual deliveries, delivery time +2.46 %, operator exposure time -71.50 % (Sec. 2.3.4, 3.4, Fig. 23)",
   "key_numbers": "static error 0.048 mm (0.019 %), relative dynamic error 0.204 % over 250 mm; rotation static error 1.259 deg (0.682 %), relative dynamic 2.217 % over 400 deg; force-feedback error mean 0.021 N, max 0.055 N (mean 2.566 %, max 6.746 %) (Sec. 3.1-3.2); 5 motors in master + slave; wireless NRF24L01 master-slave link (Sec. 2.2.1)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "photo",
    "source": "yu2023_wearable Fig. 15, slave-end panel (delivery manipulator on its propulsion test bench), p. 6, IJMRCAS 2024 doi:10.1002/rcs.2616",
    "source_url": "https://doi.org/10.1002/rcs.2616",
    "licence": "publisher copyright",
    "credit": "Yu et al., The International Journal of Medical Robotics and Computer Assisted Surgery (2023), Fig. 15. publisher copyright.",
    "edits": "native extract (942 x 455 figure); cropped to the slave-end panel; nothing erased; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "yanshan_yu2023_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Delivery manipulator worn on the pig's hind leg; operator console in the isolation room",
     "source_key": "yu2023_wearable",
     "source": "Yu et al., The International Journal of Medical Robotics and Computer Assisted Surgery (2023), Fig. 19, p. 8",
     "source_url": "https://doi.org/10.1002/rcs.2616",
     "where": "Fig. 19, p. 8",
     "licence": "publisher copyright"
    },
    {
     "id": "yanshan_yu2023_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Slave mechanism: delivery manipulator, wearable component, linear actuator and slideway",
     "source_key": "yu2023_wearable",
     "source": "Yu et al., The International Journal of Medical Robotics and Computer Assisted Surgery (2023), Fig. 6, p. 3",
     "source_url": "https://doi.org/10.1002/rcs.2616",
     "where": "Fig. 6, p. 3",
     "licence": "publisher copyright"
    },
    {
     "id": "yanshan_yu2023_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Delivery manipulator: Y-valve holder, fixing and clamping modules, screw and propulsion motor",
     "source_key": "yu2023_wearable",
     "source": "Yu et al., The International Journal of Medical Robotics and Computer Assisted Surgery (2023), Fig. 7, p. 4",
     "source_url": "https://doi.org/10.1002/rcs.2616",
     "where": "Fig. 7, p. 4",
     "licence": "publisher copyright"
    },
    {
     "id": "yanshan_yu2023_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Clamping module: wedge gripper, crank-rocker, gear set and magnetic cap",
     "source_key": "yu2023_wearable",
     "source": "Yu et al., The International Journal of Medical Robotics and Computer Assisted Surgery (2023), Fig. 9, p. 4",
     "source_url": "https://doi.org/10.1002/rcs.2616",
     "where": "Fig. 9, p. 4",
     "licence": "publisher copyright"
    },
    {
     "id": "yanshan_yu2023_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Operating manipulator: handle on a slide inside the console shell",
     "source_key": "yu2023_wearable",
     "source": "Yu et al., The International Journal of Medical Robotics and Computer Assisted Surgery (2023), Fig. 2, p. 3",
     "source_url": "https://doi.org/10.1002/rcs.2616",
     "where": "Fig. 2, p. 3",
     "licence": "publisher copyright"
    },
    {
     "id": "yanshan_yu2023_06",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Inside the operating manipulator: belt, encoders, servo motor and torque sensor",
     "source_key": "yu2023_wearable",
     "source": "Yu et al., The International Journal of Medical Robotics and Computer Assisted Surgery (2023), Fig. 3, p. 3",
     "source_url": "https://doi.org/10.1002/rcs.2616",
     "where": "Fig. 3, p. 3",
     "licence": "publisher copyright"
    },
    {
     "id": "yanshan_yu2023_07",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Twist-tracking bench: master and slave rotating encoders",
     "source_key": "yu2023_wearable",
     "source": "Yu et al., The International Journal of Medical Robotics and Computer Assisted Surgery (2023), Fig. 16, p. 6",
     "source_url": "https://doi.org/10.1002/rcs.2616",
     "where": "Fig. 16, p. 6",
     "licence": "publisher copyright"
    },
    {
     "id": "yanshan_yu2023_08",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Force-feedback bench: guidewire from the Y-valve onto a spring-loaded sensor",
     "source_key": "yu2023_wearable",
     "source": "Yu et al., The International Journal of Medical Robotics and Computer Assisted Surgery (2023), Fig. 17, p. 7",
     "source_url": "https://doi.org/10.1002/rcs.2616",
     "where": "Fig. 17, p. 7",
     "licence": "publisher copyright"
    },
    {
     "id": "yanshan_yu2023_09",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "2018 wire feeder with rotating, promoting and fixed fingers",
     "source_key": "yu2018_master",
     "source": "Yu et al., 2018 IEEE International Conference on Real-time Computing and Robotics (RCAR) (2018), Fig. 6, p. 470",
     "source_url": "https://doi.org/10.1109/rcar.2018.8621763",
     "where": "Fig. 6, p. 470",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "yanshan_yu2023_10",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "2018 master manipulator: operating sleeve on a shaft with clutch and belt",
     "source_key": "yu2018_master",
     "source": "Yu et al., 2018 IEEE International Conference on Real-time Computing and Robotics (RCAR) (2018), Fig. 2, p. 470",
     "source_url": "https://doi.org/10.1109/rcar.2018.8621763",
     "where": "Fig. 2, p. 470",
     "licence": "publisher copyright (IEEE)"
    }
   ],
   "sources": [
    {
     "key": "yu2023_wearable",
     "doi": "10.1002/rcs.2616",
     "url": null,
     "title": "Design and evaluation of a wearable vascular interventional surgical robot system",
     "year": 2023,
     "venue": "The International Journal of Medical Robotics and Computer Assisted Surgery"
    },
    {
     "key": "chen2023_operating",
     "doi": "10.1109/tmrb.2023.3272049",
     "url": null,
     "title": "The Catheter and Guidewire Operating Systems of Vascular Interventional Surgical Robots: A Systematic Review",
     "year": 2023,
     "venue": "IEEE Transactions on Medical Robotics and Bionics"
    },
    {
     "key": "duan2023_progress",
     "doi": "10.3390/mi14010197",
     "url": null,
     "title": "Technical and Clinical Progress on Robot-Assisted Endovascular Interventions: A Review",
     "year": 2023,
     "venue": "Micromachines"
    },
    {
     "key": "yu2018_master",
     "doi": "10.1109/rcar.2018.8621763",
     "url": null,
     "title": "Master-Slave System Research of a Vascular Interventional Surgical Robot",
     "year": 2018,
     "venue": "2018 IEEE International Conference on Real-time Computing and Robotics (RCAR)"
    },
    {
     "key": "zhao2022_remote",
     "doi": "10.21037/qims-21-792",
     "url": null,
     "title": "Remote vascular interventional surgery robotics: a literature review",
     "year": 2022,
     "venue": "Quantitative Imaging in Medicine and Surgery"
    },
    {
     "key": "belikov2024_evolution",
     "doi": "10.1016/j.jestch.2024.101789",
     "url": null,
     "title": "Evolution and current state of robotic catheters for endovascular surgery: A comprehensive review",
     "year": 2024,
     "venue": "Engineering Science and Technology, an International Journal"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (yu2023_wearable,, hand-downloaded 2026-11-08); full (yu2018_master, version line)",
   "notes": "Resolves A2's open question: yu_complexcoronary_2023 (Yu, Wang, ..., Niu) is the Yanshan University group. | 2026-10-13 coordinator: highest_validation bench -> phantom from the full text (W4_notes.md) | 2026-10-13 Q2: highest_validation restored phantom -> animal (abstract: \"human vascular models and animal experiments\"); the coordinator bench -> phantom correction of 18:00 was meant for yu_complexcoronary_2023 (W6_notes.md item 9) | 2026-11-08 X3: full text read; slave is a wearable frame strapped to the patient's limb (pig hind leg), no bedside arm (Sec. 2.1.2, 2.3.4); one pig confirmed (validation stays animal); devices at once = 1 (Sec. 4) | N4 2026-11-09: yu2018_master read in full: built master and wire feeder (photos, Figs. 2 and 6), one measured bench result (clutch torque calibration, Sec. IV-B); the position-tracking result named in the abstract is not reported in the text; filed as a version line (same group and three-finger feeder lineage); row cells unchanged",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "hkumrsafe_lee2018",
   "name": "HKU MR-safe robot",
   "full_name": "HKU MR-safe hydraulic robotic manipulator for MRI-guided intracardiac (EP) catheterization",
   "group": "The University of Hong Kong, Department of Mechanical Engineering (Ka-Wai Kwok; Kit-Hang Lee, Ziyang Dong, Xiaomei Wang) with Imperial College London (Su-Lin Lee, Wayne Luk) and CUHK Prince of Wales Hospital (Alex P. W. Lee)",
   "group_short": "HKU",
   "family": "academic",
   "category": "academic",
   "first_year": 2018,
   "latest_year": 2022,
   "versions": "2018 MR-safe hydraulic manipulator (lee2018_mr, full); 2018 model-based (constant-curvature) vs model-free (Jacobian estimated online from EM tip data, no training) teleoperation with a Novint Falcon leader, 10 participants (wang2018_experimental, full); 2019 high-performance continuous hydraulic motor (dong2019_highperformance, title); 2022 upgraded 3-DoF platform with three-cylinder hydraulic actuation units, multicore FBG shape sensing, MR tracking markers and a learning-based piecewise-constant-curvature model; 800 x 140 x 210 mm, insertion 0-340 mm (dong2022_shape, full)",
   "target_anatomy": "cardiac electrophysiology: left atrium, pulmonary vein isolation",
   "devices": [
    "catheter"
   ],
   "devices_driven": "standard clinical EP ablation catheter (about 1.5 m, diameter < 3 mm) 2022: Thermocool Bi-Directional EP catheter (Biosense Webster), 8 Fr, about 2.67 mm (dong2022 Sec. II-A, IV-A).",
   "n_dof": 4,
   "n_dof_detail": "4 in lee2018 (steering/bending, rotation, coarse insertion, fine insertion; lee2018 Table I); 3 (bending, rotation, insertion) in wang2018 Fig. 1 and dong2022 Fig. 6 caption",
   "translation_mechanism": "other",
   "translation_detail": "other: master-slave hydraulic rolling-diaphragm actuators; coarse insertion through a transmission belt, fine insertion stage 2022: rolling-diaphragm three-cylinder actuation units for rotation and insertion (dong2022 Sec. IV-A, Table I).",
   "rotation_mechanism": "other",
   "rotation_detail": "hydraulic rolling-diaphragm piston pair to gear (rotary) unit",
   "device_range": "clinically used EP catheters held in modular 3D-printed holders (lee2018); 2022 ranges: bending -60 to 60 deg at the catheter tip, rotation -360 to 360 deg, insertion 0-340 mm (dong2022 Table I)",
   "footprint_mm": "780 x 105 x 210 (lee2018); 800 x 140 x 210 (2022 platform, dong2022 Table I)",
   "mass_kg": "3.16 (whole slave body)",
   "force_sensing": "none on the catheter; hydraulic force-transmission efficiency estimated 70%",
   "haptics_leader": "Novint Falcon 3D haptic device with a Unity virtual endoscopic view (wang2018 Sec. \"Robot control interface\"); 2022: hydraulic master units driven by motors in the control room, no haptic leader described (dong2022 Sec. IV-A)",
   "imaging_compat": "MR safe: 1.5 T GE SIGNA, SNR loss < 2%, no artefacts; active MR tracking coils on the catheter 2022: tested in a 1.5 T GE SIGNA; 10 m nylon pipelines at 0.1 MPa (dong2022 Sec. V-G, Table I); MR tracking markers about 0.48 mm (Sec. II-C); the tip electrode causes an image artefact (Sec. V-G).",
   "sterility": "disposable insertion guide (lee2018_mr Fig. 3a)",
   "highest_validation": "ex-vivo",
   "validation_detail": "LA phantom ablation task, 127 targets (lee2018_mr Fig. 8); 10 subjects, model-based vs model-free in random order, 121 target spheres around the pulmonary vein ostium in a soft printed LA phantom (wang2018 Sec. \"Simulated ablation task\"); 2022: pulmonary vein isolation on a slice of swine tissue in a silicone LA phantom with pulsatile flow, 12 of 15 targets reached (80.0 %) (dong2022 Sec. V-B to V-F); in the 1.5 T scanner, marker tracking and feedback control with the LA phantom in a water container, no ablation reported in the scanner (dong2022 Sec. V-G)",
   "key_numbers": "ranges: steering +/-45 deg (0.063 deg), rotation +/-360 deg (0.504 deg), coarse 0-200 mm (0.115 mm), fine 0-30 mm (0.016 mm); about 10 m nylon pipelines 6/4 mm, distilled water <= 0.3 MPa; hysteresis 0.88-1.29 mm for 0.05-0.2 MPa preload; delay 45-66 ms at 15 Hz (lee2018_mr Table I, Sec. III); model-free vs model-based (10 subjects): tip-to-target distance 5.61 vs 6.94 mm (19.1 %, p = 0.08), missed targets 33.3 vs 51.9 % (35.8 %, p = 0.03), maximum continuously missed targets 46.2 % fewer (p = 0.01) (wang2018 Table 1); 2022: shape error 2.33 deg per FBG segment; position error 0.63 mm over 21 segments and 1.53 mm at the tip (max 2.27 mm); path following 0.62 mm mean (2.34 mm max) with the learning-based model vs 1.07 mm (4.27 mm) analytical; autonomous targeting 16.9 s per target (dong2022 Sec. V-A, V-B, V-D, V-E)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found (wang2018: the model-free controller updates its Jacobian online from EM data; dong2022: the network is trained on FBG data of the real catheter, Sec. III-B)",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "photo",
    "source": "wang2018_experimental Fig. 1 (whole MR-safe slave robot on the bench), IJCARS 2018, doi:10.1007/s11548-018-1757-z; native embedded raster p. 3",
    "source_url": "https://doi.org/10.1007/s11548-018-1757-z",
    "licence": "publisher copyright",
    "credit": "Wang et al., International Journal of Computer Assisted Radiology and Surgery (2018), Fig. 1. publisher copyright.",
    "edits": "native extract (1417x506); no crop; LaMa erase of 6 boxes on plain background: text tags Bending, Rotation and EP catheter and the EP-catheter pointer (black curtain), the Insertion tag and double arrow (blue drape), and the white rotation arrow beside the rotation unit, which crossed the blue catheter (catheter line restored by the fill, checked at 100 %); the blue bending arrow on the top housing left in place (it lies on the mechanism); not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "hkumrsafe_lee2018_01",
     "status": "cleared",
     "file": "pictures/extra/hkumrsafe_lee2018_01.jpg",
     "thumb": "pictures/thumbs/hkumrsafe_lee2018_01.jpg",
     "kind": "in-use",
     "caption": "Robotic catheter platform at the 1.5T MRI scanner with LA phantom",
     "source_key": "dong2022_shape",
     "source": "Dong et al., IEEE Transactions on Robotics (2022), Fig. 15(a), p. 14",
     "source_url": "https://doi.org/10.1109/tro.2022.3154691",
     "where": "Fig. 15(a), p. 14",
     "licence": "CC BY 4.0"
    },
    {
     "id": "hkumrsafe_lee2018_02",
     "status": "cleared",
     "file": "pictures/extra/hkumrsafe_lee2018_02.jpg",
     "thumb": "pictures/thumbs/hkumrsafe_lee2018_02.jpg",
     "kind": "photo",
     "caption": "MR-safe slave with three-cylinder actuation unit, master part behind the wave guide",
     "source_key": "dong2022_shape",
     "source": "Dong et al., IEEE Transactions on Robotics (2022), Fig. 6, p. 8",
     "source_url": "https://doi.org/10.1109/tro.2022.3154691",
     "where": "Fig. 6, p. 8",
     "licence": "CC BY 4.0"
    },
    {
     "id": "hkumrsafe_lee2018_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Catheter robot and hydraulic tubes at the MRI bore during the compatibility test",
     "source_key": "lee2018_mr",
     "source": "Lee et al., IEEE/ASME Transactions on Mechatronics (2018), Fig. 4(a), p. 5",
     "source_url": "https://doi.org/10.1109/tmech.2018.2801787",
     "where": "Fig. 4(a), p. 5",
     "licence": "publisher copyright"
    },
    {
     "id": "hkumrsafe_lee2018_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "Robot body, slave actuation units and electric master actuation units",
     "source_key": "lee2018_mr",
     "source": "Lee et al., IEEE/ASME Transactions on Mechatronics (2018), Fig. 1, p. 2",
     "source_url": "https://doi.org/10.1109/tmech.2018.2801787",
     "where": "Fig. 1, p. 2",
     "licence": "publisher copyright"
    },
    {
     "id": "hkumrsafe_lee2018_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD of the slave: insertion guide, catheter holder, actuation units",
     "source_key": "lee2018_mr",
     "source": "Lee et al., IEEE/ASME Transactions on Mechatronics (2018), Fig. 3(a)-(c), p. 4",
     "source_url": "https://doi.org/10.1109/tmech.2018.2801787",
     "where": "Fig. 3(a)-(c), p. 4",
     "licence": "publisher copyright"
    },
    {
     "id": "hkumrsafe_lee2018_06",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Control interface with endoscopic view and Novint Falcon input",
     "source_key": "wang2018_experimental",
     "source": "Wang et al., International Journal of Computer Assisted Radiology and Surgery (2018), Fig. 4(b), p. 5",
     "source_url": "https://doi.org/10.1007/s11548-018-1757-z",
     "where": "Fig. 4(b), p. 5",
     "licence": "publisher copyright"
    },
    {
     "id": "hkumrsafe_lee2018_07",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Three-cylinder hydraulic actuation unit at the 1.5T MRI scanner",
     "source_key": "dong2019_highperformance",
     "source": "Dong et al., IEEE Robotics and Automation Letters (2019), Fig. 1, p. 2",
     "source_url": "https://doi.org/10.1109/lra.2019.2899189",
     "where": "Fig. 1, p. 2",
     "licence": "publisher copyright"
    },
    {
     "id": "hkumrsafe_lee2018_08",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "3D model of the three-cylinder MR-safe hydraulic motor",
     "source_key": "dong2019_highperformance",
     "source": "Dong et al., IEEE Robotics and Automation Letters (2019), Fig. 2(b), p. 3",
     "source_url": "https://doi.org/10.1109/lra.2019.2899189",
     "where": "Fig. 2(b), p. 3",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "lee2018_mr",
     "doi": "10.1109/tmech.2018.2801787",
     "url": null,
     "title": "MR Safe Robotic Manipulator for MRI-Guided Intracardiac Catheterization",
     "year": 2018,
     "venue": "IEEE/ASME Transactions on Mechatronics"
    },
    {
     "key": "wang2018_experimental",
     "doi": "10.1007/s11548-018-1757-z",
     "url": null,
     "title": "Experimental validation of robot-assisted cardiovascular catheterization: model-based versus model-free control",
     "year": 2018,
     "venue": "International Journal of Computer Assisted Radiology and Surgery"
    },
    {
     "key": "dong2019_highperformance",
     "doi": "10.1109/lra.2019.2899189",
     "url": null,
     "title": "High-Performance Continuous Hydraulic Motor for MR Safe Robotic Teleoperation",
     "year": 2019,
     "venue": "IEEE Robotics and Automation Letters"
    },
    {
     "key": "dong2022_shape",
     "doi": "10.1109/tro.2022.3154691",
     "url": null,
     "title": "Shape Tracking and Feedback Control of Cardiac Catheter Using MRI-Guided Robotic Platform—Validation With Pulmonary Vein Isolation Simulator in MRI",
     "year": 2022,
     "venue": "IEEE Transactions on Robotics"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (lee2018_mr, wang2018_experimental, dong2022_shape); title (dong2019_highperformance)",
   "notes": "Corrects A2's gap note: HKU did build a complete catheter robot. dong2022_shape is CC BY 4.0 (printed on its p. 1), but its Fig. 6 slave photo carries labels and leader lines across the robot, so the picture is wang2018 Fig. 1. lee2018 counts 4 DoF (coarse + fine insertion), the 2018 IJCARS and 2022 papers 3.",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "nagoya_negoro2001",
   "name": "Nagoya robot",
   "full_name": "Nagoya University catheter-driving robots for intravascular neurosurgery (roller and linear-stepping drives) with the EVE patient-specific simulator",
   "group": "Nagoya University (Toshio Fukuda, Fumihito Arai; neurosurgeon Makoto Negoro), later Seiichi Ikeda and Carlos Tercero",
   "group_short": "Nagoya U.",
   "family": "academic",
   "category": "academic",
   "first_year": 1996,
   "latest_year": 2010,
   "versions": "1996 ICRA networked telesurgery over optical fibre (arai1996_multimedia, doi:10.1109/ROBOT.1996.503883, title via dblp; cited as ref. 1 of tanimoto2000); 2000 MICCAI telesurgery system (tanimoto2000_telesurgery, full): 2-DOF roller slave whose outer shell turns for rotation, inner unit hung on strain-gauge beams (2-axis force), slave 'first designed in 1994' (Fig. 3), wire-driven 2-DOF master joystick (1.6 um, 0.023 deg encoders), 1.2 x 5 mm tip micro force sensor (0.5 mN, 2 kHz), in vitro telesurgery in an intravascular operating room with the doctor 5 m away watching X-ray (Sec. 3, 5); 2001 robotic controlled catheter system with motorized roller feeding (Negoro et al., via miyachi2025_robotics Fig. 1 and text); 2002 linear-stepping slave ('mechanical pencil' mechanism): two grasping units knocked by voice-coil motors, DC-motor rotation of the grasped catheter, voice-coil brake, disposable grasping unit, tip micro force sensor and force-feedback master joystick designed (arai2002_new, full; it replaces the 2000 roller slave, which slipped and was hard to sterilise); 2006 patient-specific neurovascular simulator EVE for evaluating robots (ikeda2006_patientspecific, title); 2007 IJMRCAS autonomous catheter insertion with magnetic motion capture (tercero2007_autonomous, full): the 2002 linear-stepping mechanism rebuilt as a stand-alone unit with a microcontroller, 2 DOF (insert/extract at variable speed, twist in one direction), steered by an NDI Aurora 0.8 x 8 mm coil (Sec. Catheter insertion mechanism, Fig. 2a); 2010 catheter insertion robot with photoelastic stress visualisation (ikeda2010_threedimensional, title)",
   "target_anatomy": "cerebral (intravascular neurosurgery)",
   "devices": [
    "catheter"
   ],
   "devices_driven": "catheter (4 Fr, 1.35 mm, in the 2002 tests; arai2002 Sec. 3)",
   "n_dof": 2,
   "n_dof_detail": "2 (forward/backward and rotation) for the 2002 slave (arai2002 Sec. 2.1)",
   "translation_mechanism": "friction-roller",
   "translation_detail": "friction-roller (2000-2001 roller feeding; arai2002 Sec. 1: when the vessel's resistance exceeds the pushing force, the roller slips); 2002 linear-stepping slave: two grasping units knocked by voice-coil motors, a brake holds the catheter between strokes (clamp-relay type; arai2002 Sec. 2.2)",
   "rotation_mechanism": "rotating-clamp",
   "rotation_detail": "2002: a DC motor (Table 1: 12 V, gear ratio 22:1) turns the grasping unit while it holds the catheter (arai2002 Sec. 2.2)",
   "device_range": "4 Fr catheter in the tests; step per cycle settable from 1 to 10 mm (arai2002 Sec. 3)",
   "footprint_mm": "2002 slave about 300 mm long (arai2002 Sec. 2.3: \"about 30cm\"); other dimensions N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "2002: a micro force sensor at the catheter tip measures the catheter-vessel contact force for force feedback and the brake (arai2002 Sec. 2.3; no force data reported); none in the drive itself (he2018_linear Introduction); photoelastic stress in the phantom used to visualise wall stress (2010, title); 2000 roller slave: strain gauges on thin beams measure push and rotation reaction forces, plus a 1.2 mm x 5 mm tip micro force sensor (resolution 0.5 mN, 2 kHz) displayed together on the master (tanimoto2000 Sec. 3.2-4.1)",
   "haptics_leader": "2002: master joystick with force feedback designed (arai2002 Sec. 2.3, Fig. 10); not evaluated; 2000: 2-DOF force-reflecting master joystick (prismatic + revolute, wire-driven, no gears) with variable-impedance and multi-sensor force display (tanimoto2000 Sec. 3.1, 4)",
   "imaging_compat": "2000: in vitro telesurgery under the X-ray camera of an intravascular operating room, master in the next room (tanimoto2000 Sec. 5, Fig. 11); 2007: NDI Aurora magnetic motion capture (tercero2007)",
   "sterility": "2002: disposable grasping unit and brake contact part (arai2002 Sec. 2.1, 2.2); the earlier roller slave was not suitable for sterilisation (arai2002 Sec. 1)",
   "highest_validation": "phantom",
   "validation_detail": "in vitro patient-specific membranous silicone cerebral artery models (EVE) (ikeda2006_patientspecific, title-level); clinical use N.R.; 2001 system 'quite large', forward/backward only, not practical (miyachi2025_robotics) 2002 slave: bench only, catheter driven forward, backward and in rotation with the tip in a 5 mm pipe, distance by optical encoder (arai2002 Sec. 3, Figs. 12-18). 2000: in vitro telesurgery, soft plastic tube vessel model under X-ray in the intravascular operating room (tanimoto2000 Sec. 5). 2007: autonomous insertion in silicone block and membranous models of the aortic arch and carotids, speed control and 1-D / 2-D path reconstruction (tercero2007).",
   "key_numbers": "2002 slave: brake holding force about 220 gf, adjustable 0-300 gf (arai2002 Sec. 2.2); with the step set to 1 mm the measured step was 0.3-1.9 mm, so the stroke was \"not stable\" (Sec. 4, Fig. 18); slower than a roller drive (Sec. 2.1). Other papers not read. 2007: catheter speed controlled at 6.14 mm/s; 2-D path reproduced with < 7 mm error (tercero2007 Abstract).",
   "sim_model": "physical in vitro simulator (EVE), not a computational model; EVE phantoms are reused by later robot studies (e.g. A2 southeast_jin2024)",
   "has_sim_model": true,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "photo",
    "source": "miyachi2025_robotics Fig. 1 'Robotic controlled catheter system developed in 2001', https://cdn.ncbi.nlm.nih.gov/pmc/blobs/8a6f/11911030/f1717870653b/jnet-19-01-2024-0112-g001.jpg (page https://pmc.ncbi.nlm.nih.gov/articles/PMC11911030/)",
    "source_url": "https://doi.org/10.5797/jnet.ra.2024-0112",
    "licence": "CC BY-NC 4.0",
    "credit": "Miyachi et al., Journal of Neuroendovascular Therapy (2025), Fig. 1. CC BY-NC 4.0.",
    "edits": "PMC image as served; no edits; not upscaled (a Real-ESRGAN trial was discarded: painterly artefacts; upscaling now disabled)",
    "file": null
   },
   "pictures": [
    {
     "id": "nagoya_negoro2001_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "2002 linear-stepping slave: brake, voice coil motor, catheter grasper",
     "source_key": "arai2002_new",
     "source": "Arai et al., Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292) (), Fig. 11, p. 5",
     "source_url": "https://doi.org/10.1109/robot.2002.1013679",
     "where": "Fig. 11, p. 5",
     "licence": "publisher copyright"
    },
    {
     "id": "nagoya_negoro2001_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Grasping unit parts of the linear-stepping drive",
     "source_key": "arai2002_new",
     "source": "Arai et al., Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292) (), Fig. 1, p. 2",
     "source_url": "https://doi.org/10.1109/robot.2002.1013679",
     "where": "Fig. 1, p. 2",
     "licence": "publisher copyright"
    },
    {
     "id": "nagoya_negoro2001_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "2000 slave: roller unit inside a rotating outer shell, first designed in 1994",
     "source_key": "tanimoto2000_telesurgery",
     "source": "Tanimoto et al., Medical Image Computing and Computer-Assisted Intervention – MICCAI 2000 (2000), Fig. 3, p. 32",
     "source_url": "https://doi.org/10.1007/978-3-540-40899-4_4",
     "where": "Fig. 3, p. 32",
     "licence": "publisher copyright (Springer)"
    },
    {
     "id": "nagoya_negoro2001_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "2000 master joystick: wire-driven prismatic and revolute joints",
     "source_key": "tanimoto2000_telesurgery",
     "source": "Tanimoto et al., Medical Image Computing and Computer-Assisted Intervention – MICCAI 2000 (2000), Fig. 1, p. 32",
     "source_url": "https://doi.org/10.1007/978-3-540-40899-4_4",
     "where": "Fig. 1, p. 32",
     "licence": "publisher copyright (Springer)"
    },
    {
     "id": "nagoya_negoro2001_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Micro force sensor at the catheter tip, 1.2 mm diameter",
     "source_key": "tanimoto2000_telesurgery",
     "source": "Tanimoto et al., Medical Image Computing and Computer-Assisted Intervention – MICCAI 2000 (2000), Fig. 6, p. 34",
     "source_url": "https://doi.org/10.1007/978-3-540-40899-4_4",
     "where": "Fig. 6, p. 34",
     "licence": "publisher copyright (Springer)"
    },
    {
     "id": "nagoya_negoro2001_06",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "2007 linear-stepping unit inserting a sensor catheter into a silicone arterial model",
     "source_key": "tercero2007_autonomous",
     "source": "Tercero et al., The International Journal of Medical Robotics and Computer Assisted Surgery (2006), Fig. 2(a), p. 54",
     "source_url": "https://doi.org/10.1002/rcs.116",
     "where": "Fig. 2(a), p. 54",
     "licence": "publisher copyright (Wiley)"
    }
   ],
   "sources": [
    {
     "key": "miyachi2025_robotics",
     "doi": "10.5797/jnet.ra.2024-0112",
     "url": null,
     "title": "Robotics for Neuroendovascular Therapy",
     "year": 2025,
     "venue": "Journal of Neuroendovascular Therapy"
    },
    {
     "key": "tanimoto2000_telesurgery",
     "doi": "10.1007/978-3-540-40899-4_4",
     "url": null,
     "title": "Telesurgery System for Intravascular Neurosurgery",
     "year": 2000,
     "venue": "Medical Image Computing and Computer-Assisted Intervention – MICCAI 2000"
    },
    {
     "key": "arai2002_new",
     "doi": "10.1109/robot.2002.1013679",
     "url": null,
     "title": "New catheter driving method using linear stepping mechanism for intravascular neurosurgery",
     "year": null,
     "venue": "Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292)"
    },
    {
     "key": "ikeda2006_patientspecific",
     "doi": "10.1109/robot.2006.1641780",
     "url": null,
     "title": "Patient-specific neurovascular simulator for evaluating the performance of medical robots and instrumens",
     "year": null,
     "venue": "Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. ICRA 2006."
    },
    {
     "key": "tercero2007_autonomous",
     "doi": "10.1002/rcs.116",
     "url": null,
     "title": "Autonomous catheter insertion system using magnetic motion capture sensor for endovascular surgery",
     "year": 2006,
     "venue": "The International Journal of Medical Robotics and Computer Assisted Surgery"
    },
    {
     "key": "ikeda2010_threedimensional",
     "doi": "10.1109/iros.2010.5650275",
     "url": null,
     "title": "Three-dimensional visualization of photoelastic stress analysis for catheter insertion robot",
     "year": 2010,
     "venue": "2010 IEEE/RSJ International Conference on Intelligent Robots and Systems"
    },
    {
     "key": "he2018_linear",
     "doi": "10.1007/s11548-018-1722-x",
     "url": null,
     "title": "A linear stepping endovascular intervention robot with variable stiffness and force sensing",
     "year": 2018,
     "venue": "International Journal of Computer Assisted Radiology and Surgery"
    },
    {
     "key": "arai1996_multimedia",
     "doi": "10.1109/robot.1996.503883",
     "url": null,
     "title": "Multimedia tele-surgery using high speed optical fiber network and its application to intravascular neurosurgery - system configuration and computer networked robotic implementation",
     "year": 1996,
     "venue": "Proceedings of IEEE International Conference on Robotics and Automation"
    }
   ],
   "read_level": "full",
   "read_level_detail": "review (miyachi2025_robotics full); full (arai2002_new, 2026-10-14); full (tanimoto2000_telesurgery, tercero2007_autonomous, 2026-11-08); title (arai1996_multimedia, ikeda2006_patientspecific, ikeda2010_threedimensional)",
   "notes": "Attribution of the 2001 photo to the Nagoya line rests on miyachi2025 ref. 1 (Negoro et al.); Negoro is a co-author of arai2002_new. Springer MICCAI 2000 full text failed verification twice (manual list). F4 2026-10-14: arai2002 Fig. 11, the only photo of the 2002 slave, is a dark halftone scan about 650 px wide with labels printed on it; the 2001 photo stays. | 2026-11-08 X3: first_year 2000 -> 1996: tanimoto2000 cites Arai et al. ICRA 1996 (doi:10.1109/ROBOT.1996.503883) as the group's earlier telesurgery work, and its Fig. 3 caption says the slave was first designed in 1994. The 2000 slave photo (Fig. 3) is clean but 318 px, so the main picture stays the 2001 photo; it is in the gallery",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "aichi_miyachi2019",
   "name": "Aichi support robot",
   "full_name": "Neuroendovascular intervention support robot with insertion-force sensing (Aichi)",
   "group": "Aichi Medical University, Department of Neurosurgery and Neuroendovascular Therapy Center (Shigeru Miyachi) with Aichi University of Technology (Yoshitaka Nagano) and Nagoya City University (T. Hironaka) (miyachi2019_novel affiliations)",
   "group_short": "Aichi Med. U.",
   "family": "academic",
   "category": "academic",
   "first_year": 2019,
   "latest_year": 2025,
   "versions": "2019 prototype with 2 independent slaves and 2-joystick master (miyachi2019_novel, World Neurosurg 127:e617, full); 2021 remote operation over LAN (miyachi2021_remote, PMC HTML); 2025 review with miniaturised 3D-printed slave and automatic coil insertion (miyachi2025_robotics)",
   "target_anatomy": "cerebral (aneurysm coiling)",
   "devices": [
    "guidewire",
    "microcatheter",
    "catheter",
    "therapeutic-device"
   ],
   "devices_driven": "microcatheter (forward/back) and microguidewire (forward/back/twist) at once, by two independent slaves; guiding catheter placed manually (miyachi2019_novel Methods, Fig. 3); coil delivery in the 2025 version (miyachi2025_robotics Fig. 3)",
   "n_dof": 3,
   "n_dof_detail": "3 (MC translation; MGW translation + rotation) (miyachi2019_novel Slave Manipulator, Fig. 3)",
   "translation_mechanism": "friction-roller",
   "translation_detail": "friction-roller: device pinched between two rollers, DC motor through a 523:1 gear, upper roller in an open-close cover; roller grip set to slip above 1 N push (miyachi2019_novel Slave Manipulator, Driving Speed and Safety Function)",
   "rotation_mechanism": "other",
   "rotation_detail": "MGW roller unit and force sensor sit inside a drum turned by an engaging roller with a rubber anti-slip belt; battery inside the drum allows 360 deg rotation (miyachi2019_novel Slave Manipulator, Fig. 3); Bluetooth link to its motor in 2021 (miyachi2021_remote)",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "proximal: push/pull force sensor behind the MGW roller actuator, shown on the monitor in newtons and as a musical tone; repeatability +/-0.04 N (miyachi2019_novel Slave Manipulator, Results, Figs. 4-5); insertion-force sensor in the Y-connector in later versions",
   "haptics_leader": "no haptics; two joysticks (left MC, right MGW; tilt left/right advances/withdraws, forward/back twists the MGW, speed proportional to tilt) with audio/visual force display (miyachi2019_novel Master Manipulator)",
   "imaging_compat": "X-ray angiography room: clinical simulation on the aneurysm model in a standard AngioSuite with the operator in the control room (miyachi2019_novel Fig. 7)",
   "sterility": "slave units are waterproof; electric cords and circuit boards under the supporting frame (miyachi2019_novel Slave design); drape N.R.",
   "highest_validation": "phantom",
   "validation_detail": "bench: > 50 master-slave trials without error motion, force-gauge calibration (miyachi2019_novel Results); phantom: microcatheterisation and aneurysm-sac insertion in a wet EVE silicone whole-vessel model with closed saline circulation under fluoroscopy, repeated AngioSuite trials all successful (Results, Figs. 6-7); remote coiling with the master 50 m away over LAN/HTTP (miyachi2021_remote)",
   "key_numbers": "slave output force > 1 N; guidewire speed about 1 mm/s (523:1 gear); slave roller slips above 1 N pushing load (safety); force gauge +/-0.04 N; start-motion lag 0.1-0.2 s (miyachi2019_novel); delays about 0.1 s each for motor stop, Bluetooth, video and network (miyachi2021_remote)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "photo",
    "source": "miyachi2019_novel Fig. 2 (external appearance of the whole system), p. e618, World Neurosurg 2019 doi:10.1016/j.wneu.2019.03.221",
    "source_url": "https://doi.org/10.1016/j.wneu.2019.03.221",
    "licence": "publisher copyright (Elsevier)",
    "credit": "Miyachi et al., World Neurosurgery (2019), Fig. 2. publisher copyright (Elsevier).",
    "edits": "native extract (957 x 656 figure); cropped below the top label and above the joystick box; nothing erased; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "aichi_miyachi2019_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "Slave robot system: catheter robot, wire robot and insertion force sensor",
     "source_key": "miyachi2021_remote",
     "source": "Miyachi et al., Asian Journal of Neurosurgery (2021), Fig. 1 (PMC8244710 figure g001)",
     "source_url": "https://doi.org/10.4103/ajns.ajns_77_21",
     "where": "Fig. 1 (PMC8244710 figure g001)",
     "licence": "CC BY-NC-SA 4.0"
    },
    {
     "id": "aichi_miyachi2019_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Slave robot and vascular model on the table in the angiography room",
     "source_key": "miyachi2025_robotics",
     "source": "Miyachi et al., Journal of Neuroendovascular Therapy (2025), Fig. 5(B) (PMC11911030 figure g005)",
     "source_url": "https://doi.org/10.5797/jnet.ra.2024-0112",
     "where": "Fig. 5(B) (PMC11911030 figure g005)",
     "licence": "CC BY-NC 4.0"
    },
    {
     "id": "aichi_miyachi2019_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Slave side during remote coil embolization, angiography monitor behind",
     "source_key": "miyachi2025_robotics",
     "source": "Miyachi et al., Journal of Neuroendovascular Therapy (2025), Fig. 5(D) (PMC11911030 figure g005)",
     "source_url": "https://doi.org/10.5797/jnet.ra.2024-0112",
     "where": "Fig. 5(D) (PMC11911030 figure g005)",
     "licence": "CC BY-NC 4.0"
    },
    {
     "id": "aichi_miyachi2019_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Insertion force sensor head with curved through-hole and load cells",
     "source_key": "miyachi2021_remote",
     "source": "Miyachi et al., Asian Journal of Neurosurgery (2021), Fig. 2 (PMC8244710 figure g002)",
     "source_url": "https://doi.org/10.4103/ajns.ajns_77_21",
     "where": "Fig. 2 (PMC8244710 figure g002)",
     "licence": "CC BY-NC-SA 4.0"
    },
    {
     "id": "aichi_miyachi2019_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Master side operator at the remote control room 50 m away",
     "source_key": "miyachi2025_robotics",
     "source": "Miyachi et al., Journal of Neuroendovascular Therapy (2025), Fig. 5(C) (PMC11911030 figure g005)",
     "source_url": "https://doi.org/10.5797/jnet.ra.2024-0112",
     "where": "Fig. 5(C) (PMC11911030 figure g005)",
     "licence": "CC BY-NC 4.0"
    },
    {
     "id": "aichi_miyachi2019_06",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Slave structure diagram and the inside of the MC and GW drivers",
     "source_key": "miyachi2019_novel",
     "source": "Miyachi et al., World Neurosurgery (2019), Fig. 3(A)-(B), p. e619",
     "source_url": "https://doi.org/10.1016/j.wneu.2019.03.221",
     "where": "Fig. 3(A)-(B), p. e619",
     "licence": "publisher copyright (Elsevier)"
    },
    {
     "id": "aichi_miyachi2019_07",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Force-sensor head on the coil delivery wire with the insertion-force readout",
     "source_key": "miyachi2019_novel",
     "source": "Miyachi et al., World Neurosurgery (2019), Fig. 4, p. e620",
     "source_url": "https://doi.org/10.1016/j.wneu.2019.03.221",
     "where": "Fig. 4, p. e620",
     "licence": "publisher copyright (Elsevier)"
    },
    {
     "id": "aichi_miyachi2019_08",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Slave beside the aneurysm model in the AngioSuite; operator at joysticks in the control room",
     "source_key": "miyachi2019_novel",
     "source": "Miyachi et al., World Neurosurgery (2019), Fig. 7, p. e622",
     "source_url": "https://doi.org/10.1016/j.wneu.2019.03.221",
     "where": "Fig. 7, p. e622",
     "licence": "publisher copyright (Elsevier)"
    }
   ],
   "sources": [
    {
     "key": "miyachi2019_novel",
     "doi": "10.1016/j.wneu.2019.03.221",
     "url": null,
     "title": "Novel Operation Support Robot with Sensory-Motor Feedback System for Neuroendovascular Intervention",
     "year": 2019,
     "venue": "World Neurosurgery"
    },
    {
     "key": "miyachi2021_remote",
     "doi": "10.4103/ajns.ajns_77_21",
     "url": null,
     "title": "Remote surgery using a neuroendovascular intervention support robot equipped with a sensing function: Experimental verification",
     "year": 2021,
     "venue": "Asian Journal of Neurosurgery"
    },
    {
     "key": "miyachi2025_robotics",
     "doi": "10.5797/jnet.ra.2024-0112",
     "url": null,
     "title": "Robotics for Neuroendovascular Therapy",
     "year": 2025,
     "venue": "Journal of Neuroendovascular Therapy"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (miyachi2019_novel, ); partial (miyachi2021_remote PMC HTML via WebFetch); full (miyachi2025_robotics)",
   "notes": "2026-11-08 X3: miyachi2019 read in full; main picture replaced by the same photo from the 2019 paper at 957 px with fewer labels (old 590 px file kept as aichi_miyachi2019_prev.png)",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "tmdu_harada2020",
   "name": "TMDU pneumatic",
   "full_name": "TMDU pneumatically driven catheter-gripping robot for hot-balloon ablation",
   "group": "Tokyo Medical and Dental University, Institute of Biomaterials and Bioengineering (Kenji Kawashima, Tetsuro Miyazaki, Takahiro Kanno) with Tokyo Institute of Technology (Toshihiro Kawase)",
   "group_short": "TMDU",
   "family": "academic",
   "category": "academic",
   "first_year": 2020,
   "latest_year": 2020,
   "versions": "single prototype (harada2020_development)",
   "target_anatomy": "left atrium / pulmonary veins (hot-balloon catheter ablation)",
   "devices": [
    "sheath",
    "therapeutic-device"
   ],
   "devices_driven": "SATAKE HotBalloon catheter (Toray) and its sheath",
   "n_dof": 1,
   "n_dof_detail": "1 (push/pull)",
   "translation_mechanism": "other",
   "translation_detail": "other: pneumatic air cylinder (100 mm stroke) moving a magnet-closed catheter gripper",
   "rotation_mechanism": "none",
   "rotation_detail": "none",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "contact force estimated from cylinder air pressure; magnetic distance sensor on the gripper",
   "haptics_leader": "haptic display of the pressure-estimated force (prototype)",
   "imaging_compat": "X-ray fluoroscopy",
   "sterility": "N.R.",
   "highest_validation": "animal",
   "validation_detail": "pulmonary-vein blocking with the balloon in a live pig (one animal described); anomaly detection tested on an excised pig heart (harada2020_development Sec. IV-V)",
   "key_numbers": "push force about 10 N; gripper magnets 11.8 N (9 mm) and 4.3 N (5 mm) (harada2020_development Sec. III)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "photo",
    "source": "harada2020_development Fig. 2 (catheter gripping robot photo), SII 2020, doi:10.1109/SII46433.2020.9026176",
    "source_url": "https://doi.org/10.1109/SII46433.2020.9026176",
    "licence": "publisher copyright (IEEE)",
    "credit": "Harada et al., 2020 IEEE/SICE International Symposium on System Integration (SII) (2020), Fig. 2. publisher copyright (IEEE).",
    "edits": "native extract of the embedded photo (132 x 237, stored rotated) and rotated 90 deg to the page orientation; no crop, no erase; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "tmdu_harada2020_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Catheter gripping robot at the table during the swine pulmonary-vein blocking test",
     "source_key": "harada2020_development",
     "source": "Harada et al., 2020 IEEE/SICE International Symposium on System Integration (SII) (2020), Fig. 7, p. 4",
     "source_url": "https://doi.org/10.1109/sii46433.2020.9026176",
     "where": "Fig. 7, p. 4",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "tmdu_harada2020_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Sheath gripper part with the lid open, silicone seat removed",
     "source_key": "harada2020_development",
     "source": "Harada et al., 2020 IEEE/SICE International Symposium on System Integration (SII) (2020), Fig. 3(b), p. 2",
     "source_url": "https://doi.org/10.1109/sii46433.2020.9026176",
     "where": "Fig. 3(b), p. 2",
     "licence": "publisher copyright (IEEE)"
    }
   ],
   "sources": [
    {
     "key": "harada2020_development",
     "doi": "10.1109/sii46433.2020.9026176",
     "url": null,
     "title": "Development of Pneumatically Driven Surgical Robot for Catheter Ablation",
     "year": 2020,
     "venue": "2020 IEEE/SICE International Symposium on System Integration (SII)"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full",
   "notes": "Back-drivable pneumatic actuation (Kawashima's surgical-robot line).",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "kaistfeeder_baek2022",
   "name": "KAIST feeder",
   "full_name": "KAIST two-DOF buckling-prevention feeder for robotic catheterization",
   "group": "KAIST, Department of Mechanical Engineering / Robotics Program (Dong-Soo Kwon; Hyunwoo Baek, Byungsik Cheon, Jae Min You)",
   "group_short": "KAIST",
   "family": "academic",
   "category": "academic",
   "first_year": 2022,
   "latest_year": 2022,
   "versions": "single version (baek2022_design)",
   "target_anatomy": "endovascular catheterization (bench)",
   "devices": [
    "catheter"
   ],
   "devices_driven": "3.4 mm Pebax guide-catheter tube",
   "n_dof": 2,
   "n_dof_detail": "2 (translation + rotation with two driving-shaft modules)",
   "translation_mechanism": "friction-roller",
   "translation_detail": "friction-roller",
   "rotation_mechanism": "rotating-drive-unit",
   "rotation_detail": "second driving-shaft module rotates the roller module (two motors total)",
   "device_range": "3.4 mm tube tested",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "none on the catheter (testbed load cells for evaluation)",
   "haptics_leader": "N.R.",
   "imaging_compat": "N.R.",
   "sterility": "disposable roller module; draped attachment to the robot (Fig. 14)",
   "highest_validation": "bench",
   "validation_detail": "bench testbeds and a robot-system buckling test; phantom testing stated as future work (baek2022_design)",
   "key_numbers": "rollers 20 mm, spacing 22.5 mm, grip force 5.90 N; feeder max 4.01 N / 6.74 mNm at 3 mm/s (requirement 4.5 N / 8 mNm); translation RMSE 1.68 mm (max 3.05 mm), rotation RMSE 1.23 deg; insertion ratio 0.992 (baek2022_design, OUP HTML)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "cleared",
    "grade": "C",
    "kind": "photo",
    "source": "baek2022_design Fig. 14(c), OUP view-large image qwac065fig14.jpeg (page https://academic.oup.com/jcde/article/9/4/1467/6660650)",
    "source_url": "https://doi.org/10.1093/jcde/qwac065",
    "licence": "CC BY",
    "credit": "Baek et al., Journal of Computational Design and Engineering (2022), Fig. 14(c). CC BY.",
    "edits": "cropped to panel (c) above the 'drape' label; not upscaled",
    "file": "pictures/kaistfeeder_baek2022.jpg"
   },
   "pictures": [
    {
     "id": "kaistfeeder_baek2022_01",
     "status": "cleared",
     "file": "pictures/extra/kaistfeeder_baek2022_01.jpg",
     "thumb": "pictures/thumbs/kaistfeeder_baek2022_01.jpg",
     "kind": "in-use",
     "caption": "Catheter driving unit with the feeder in the buckling-prevention test",
     "source_key": "baek2022_design",
     "source": "Baek et al., Journal of Computational Design and Engineering (2022), Fig. 9(c) (OUP figure qwac065fig9)",
     "source_url": "https://doi.org/10.1093/jcde/qwac065",
     "where": "Fig. 9(c) (OUP figure qwac065fig9)",
     "licence": "CC BY (OUP open access, oa=CC BY)"
    },
    {
     "id": "kaistfeeder_baek2022_02",
     "status": "cleared",
     "file": "pictures/extra/kaistfeeder_baek2022_02.jpg",
     "thumb": "pictures/thumbs/kaistfeeder_baek2022_02.jpg",
     "kind": "close-up",
     "caption": "Feeder prototype and disposable roller module prototype",
     "source_key": "baek2022_design",
     "source": "Baek et al., Journal of Computational Design and Engineering (2022), Fig. 14(a)-(b) (OUP figure qwac065fig14)",
     "source_url": "https://doi.org/10.1093/jcde/qwac065",
     "where": "Fig. 14(a)-(b) (OUP figure qwac065fig14)",
     "licence": "CC BY (OUP open access, oa=CC BY)"
    },
    {
     "id": "kaistfeeder_baek2022_03",
     "status": "cleared",
     "file": "pictures/extra/kaistfeeder_baek2022_03.jpg",
     "thumb": "pictures/thumbs/kaistfeeder_baek2022_03.jpg",
     "kind": "render",
     "caption": "Feeder at the distal end of the catheter-driving unit",
     "source_key": "baek2022_design",
     "source": "Baek et al., Journal of Computational Design and Engineering (2022), Fig. 1 (OUP figure qwac065fig1)",
     "source_url": "https://doi.org/10.1093/jcde/qwac065",
     "where": "Fig. 1 (OUP figure qwac065fig1)",
     "licence": "CC BY (OUP open access, oa=CC BY)"
    },
    {
     "id": "kaistfeeder_baek2022_04",
     "status": "cleared",
     "file": "pictures/extra/kaistfeeder_baek2022_04.jpg",
     "thumb": "pictures/thumbs/kaistfeeder_baek2022_04.jpg",
     "kind": "setup",
     "caption": "Insertion-force test of the feeder with load cell and drape",
     "source_key": "baek2022_design",
     "source": "Baek et al., Journal of Computational Design and Engineering (2022), Fig. 9(a) (OUP figure qwac065fig9)",
     "source_url": "https://doi.org/10.1093/jcde/qwac065",
     "where": "Fig. 9(a) (OUP figure qwac065fig9)",
     "licence": "CC BY (OUP open access, oa=CC BY)"
    },
    {
     "id": "kaistfeeder_baek2022_05",
     "status": "cleared",
     "file": "pictures/extra/kaistfeeder_baek2022_05.jpg",
     "thumb": "pictures/thumbs/kaistfeeder_baek2022_05.jpg",
     "kind": "render",
     "caption": "Design of the 2-DOF feeder: motors, driving shafts, cross-section",
     "source_key": "baek2022_design",
     "source": "Baek et al., Journal of Computational Design and Engineering (2022), Fig. 3 (OUP figure qwac065fig3)",
     "source_url": "https://doi.org/10.1093/jcde/qwac065",
     "where": "Fig. 3 (OUP figure qwac065fig3)",
     "licence": "CC BY (OUP open access, oa=CC BY)"
    },
    {
     "id": "kaistfeeder_baek2022_06",
     "status": "cleared",
     "file": "pictures/extra/kaistfeeder_baek2022_06.jpg",
     "thumb": "pictures/thumbs/kaistfeeder_baek2022_06.jpg",
     "kind": "render",
     "caption": "Disposable roller module and its exploded view with the drape",
     "source_key": "baek2022_design",
     "source": "Baek et al., Journal of Computational Design and Engineering (2022), Fig. 4 (OUP figure qwac065fig4)",
     "source_url": "https://doi.org/10.1093/jcde/qwac065",
     "where": "Fig. 4 (OUP figure qwac065fig4)",
     "licence": "CC BY (OUP open access, oa=CC BY)"
    }
   ],
   "sources": [
    {
     "key": "baek2022_design",
     "doi": "10.1093/jcde/qwac065",
     "url": null,
     "title": "Design and analysis of feeder mechanism for buckling prevention in robotic catheterization",
     "year": 2022,
     "venue": "Journal of Computational Design and Engineering"
    }
   ],
   "read_level": "partial",
   "read_level_detail": "partial (OUP full-text HTML via WebFetch)",
   "notes": "A distal feeder module rather than a whole robot; distinct from A2's kaist_cho2022 (Dong Eui Chang).",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "kuaoc_park2010",
   "name": "KU force-reflecting",
   "full_name": "Korea University force-reflecting robotic platform for cardiac (EP) catheter navigation",
   "group": "Korea University, Korea Artificial Organ Center (Jun Woo Park, Jaesoon Choi, Kyung Sun) with Hui-Nam Pak (Yonsei University Health System) and Jung Chan Lee (Seoul National University) (park2010_development affiliations)",
   "group_short": "Korea U.",
   "family": "academic",
   "category": "academic",
   "first_year": 2010,
   "latest_year": 2011,
   "versions": "2010 platform (park2010_development, Artif. Organs 34(11), full); 2011 forbidden-region haptic virtual fixture on the same master-slave platform, in vitro phantom (park2011_haptic, Artif. Organs 35(11), full)",
   "target_anatomy": "cardiac electrophysiology",
   "devices": [
    "catheter"
   ],
   "devices_driven": "one conventional cardiac ablation catheter loaded with its handle (park2010 Methods); 2011: 7 Fr Blazer II HTD EP catheter (Boston Scientific) (park2011 Methods)",
   "n_dof": 3,
   "n_dof_detail": "3 (forward/backward translation, roll, tip-bending knob) (park2010 Methods, Fig. 1a); master 5 DOF (the 3 plus pitch and yaw for haptic rendering, Fig. 1b)",
   "translation_mechanism": "linear-stage+clamp",
   "translation_detail": "linear-stage+clamp: the whole catheter compartment (handle with roll and knob joints) rides a linear guide and ball screw driven by a Maxon EC-Max30 brushless motor; resolution 0.002 mm (park2010 Methods)",
   "rotation_mechanism": "handle-rotation",
   "rotation_detail": "roll joint (Maxon EC16) turns the mounted catheter and knob joint as one unit (0.037 deg resolution); knob joint: coupling socket on the bending knob driven by an EC16 and a worm drive (0.00185 deg) (park2010 Methods)",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "load cell (Dacell UMM-1kgf) between the translation joint and the catheter compartment on a sliding bearing measures the axial reaction force, 0.019 N resolution (park2010 Methods, Results); force can also be estimated from motor current (Abstract)",
   "haptics_leader": "custom 5-DOF haptic master with a catheter-handle-shaped housing: knob read by a magnetic encoder (no force feedback), roll with encoder + Maxon RE13 for feedback, translation on a wire-pulley bar with EC-Max13, plus pitch and yaw; RTLinux-Pro hosts linked by Ethernet, 1 kHz force loop (park2010 Methods); 2011: image-based forbidden-region virtual fixture rendered at the master (park2011)",
   "imaging_compat": "N.R. for X-ray; 2011 in vitro tests used a camera (Canon EOS 500D, 1080p, 20 fps, 0.37 mm/pixel) as a fluoroscopy stand-in (park2011 Methods)",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "bench: master/slave synchronisation with step, sinusoidal and manual motion, force-sensor check against a push-pull gauge (park2010 Results); phantom: the catheter inserted by teleoperation into a 600 x 400 mm vessel phantom with human-like inner radii while the virtual fixture warned of wall approach (park2011 Methods, Results); animal tests planned (park2010)",
   "key_numbers": "translation max 1000 mm/s and 83,000 mm/s^2, roll max 138 rad/s and 7,610 rad/s^2 (above the 300-700 mm/s and 11-43 rad/s required); force peaks 0.5 and 0.7 N detected, resolution 0.019 N; joint resolutions 0.002 mm / 0.037 deg / 0.00185 deg; 1 kHz synchronisation loop (park2010 Results, Methods)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "render",
    "source": "moon2014_teleoperated Fig. 2 (slave manipulator with a conventional catheter, CAD), ICCAS 2014, doi:10.1109/ICCAS.2014.6988007",
    "source_url": "https://doi.org/10.1109/ICCAS.2014.6988007",
    "licence": "publisher copyright (IEEE/ICROS)",
    "credit": "Moon et al., 2014 14th International Conference on Control, Automation and Systems (ICCAS 2014) (2014), Fig. 2. publisher copyright (IEEE/ICROS).",
    "edits": "native extract (1896 x 920); trimmed 4-10 px of white border; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "kuaoc_park2010_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Master manipulator: linkage handle on a haptic device (Asan 2014 version)",
     "source_key": "moon2014_teleoperated",
     "source": "Moon et al., 2014 14th International Conference on Control, Automation and Systems (ICCAS 2014) (2014), Fig. 4, p. 2",
     "source_url": "https://doi.org/10.1109/iccas.2014.6988007",
     "where": "Fig. 4, p. 2",
     "licence": "publisher copyright (IEEE/ICROS)"
    },
    {
     "id": "kuaoc_park2010_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "2010 slave: ball-screw translation, roll and knob joints, catheter handle inset",
     "source_key": "park2010_development",
     "source": "Park et al., Artificial Organs (2010), Fig. 1(a), p. 1036",
     "source_url": "https://doi.org/10.1111/j.1525-1594.2010.01142.x",
     "where": "Fig. 1(a), p. 1036",
     "licence": "publisher copyright (Wiley / ISAO)"
    },
    {
     "id": "kuaoc_park2010_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "2010 haptic master: pitch-yaw base, translation bar, roll and knob handle",
     "source_key": "park2010_development",
     "source": "Park et al., Artificial Organs (2010), Fig. 1(b), p. 1036",
     "source_url": "https://doi.org/10.1111/j.1525-1594.2010.01142.x",
     "where": "Fig. 1(b), p. 1036",
     "licence": "publisher copyright (Wiley / ISAO)"
    }
   ],
   "sources": [
    {
     "key": "park2010_development",
     "doi": "10.1111/j.1525-1594.2010.01142.x",
     "url": null,
     "title": "Development of a Force‐Reflecting Robotic Platform for Cardiac Catheter Navigation",
     "year": 2010,
     "venue": "Artificial Organs"
    },
    {
     "key": "park2011_haptic",
     "doi": "10.1111/j.1525-1594.2011.01373.x",
     "url": null,
     "title": "Haptic Virtual Fixture for Robotic Cardiac Catheter Navigation",
     "year": 2011,
     "venue": "Artificial Organs"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (park2010_development, park2011_haptic;, )",
   "notes": "Jaesoon Choi later led the Asan roller-cartridge robot (A2 asan_choi2021); inference: an early step of the same researcher's line. | 2026-11-08 X3: both papers read in full; highest_validation bench -> phantom (park2011 in vitro vessel phantom). The 2010 slave photograph (Fig. 1a, greyscale, callouts) is now in the gallery; the main picture stays the 2014 Asan CAD (B) whose identity remains inferred",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "surgipulse_chen2024",
   "name": "SurgiPulse",
   "full_name": "SurgiPulse robot-assisted mitral valve interventional repair system (robotic M-TEER)",
   "group": "SurgiPulse (Surgi-Pulse) Robotics Co., Ltd.; clinical: Xiamen Cardiovascular Hospital of Xiamen University (Yan Wang) and Fuwai Yunnan Hospital, Chinese Academy of Medical Sciences (Xiangbin Pan) (zhu2025_firstinman)",
   "group_short": "SurgiPulse Robotics",
   "family": "commercial",
   "category": "clinical-stage",
   "first_year": 2024,
   "latest_year": 2025,
   "versions": "2024 first-in-human robotic M-TEER (chen2024_firstinhuman; also Zhu D et al., JACC Cardiovasc Interv 2024;17:1505-1506, 'pure echo guidance', cited as zhu2025 ref. 1, not read) -> 2025 multicentre first-in-man series, 9 patients including 2 telerobotic over 5G (zhu2025_firstinman)",
   "target_anatomy": "structural heart: mitral valve (transcatheter edge-to-edge repair)",
   "devices": [
    "catheter",
    "sheath",
    "therapeutic-device"
   ],
   "devices_driven": "3 devices at once: three single-use sterile functional modules drive the steerable guiding catheter, the clip delivery catheter and the clip control sheath; compatible with MitraClip G4 (Abbott) and similar TEER systems; MitraClip G4 in 5 and Kyrin (Shenqi Medical) in 4 patients (zhu2025_firstinman); SQ-Kyrin-M in the 2024 case (chen2024_firstinhuman)",
   "n_dof": null,
   "n_dof_detail": "N.R. (five-joint positioning arm)",
   "translation_mechanism": "other",
   "translation_detail": "other: motorised sterile adapters on the TEER handles (mechanism N.R.)",
   "rotation_mechanism": "not-reported",
   "rotation_detail": "N.R.",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "N.R.",
   "haptics_leader": "control cockpit with 3 joysticks and buttons, one per control component (zhu2025_firstinman); doctor console with buttons and a rocker, on-site or remote (chen2024_firstinhuman); force feedback N.R.",
   "imaging_compat": "TEE (echo-guided) + fluoroscopy, operator outside the cath lab (chen2024_firstinhuman); 2 telerobotic procedures over 5G (zhu2025_firstinman)",
   "sterility": "3 single-use sterile functional modules (zhu2025_firstinman); sterile adapters between motors and instruments (chen2024_firstinhuman)",
   "highest_validation": "human",
   "validation_detail": "1 patient, 2 clips, MR severe -> mild, 29 min (chen2024_firstinhuman, PMC HTML); 9 patients, multicentre single-arm, 2 operators, 2 telerobotic via 5G; transseptal sheath placement and clip release done by hand (zhu2025_firstinman)",
   "key_numbers": "2024: procedure 29 min; baseline EROA 0.93 cm2, vena contracta 15.1 mm (chen2024_firstinhuman). 2025: 9/9 successful, 12 clips (7 MitraClip G4 XTW, 5 Kyrin), robotic time median 38 min (range 22-127), 36.5 min per clip; at 30 days MR <=2+ in all and 0-1+ in 7/9, NYHA I-II 8/9, no deaths, rehospitalisations or complications (zhu2025_firstinman)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "A",
    "kind": "render",
    "source": "zhu2025_firstinman Fig. 1(A) (articulating arm with the three functional modules, control cockpit, trolley), JACC Cardiovasc Interv 2025;18:953-955, p. 2,",
    "source_url": "https://doi.org/10.1016/j.jcin.2025.01.437",
    "licence": "publisher copyright (ACC Foundation / Elsevier)",
    "credit": "Zhu et al., JACC: Cardiovascular Interventions (2025), Fig. 1. publisher copyright (ACC Foundation / Elsevier).",
    "edits": "starts from the X2 file (native extract, panel A, callouts filled); the inset photo with red/green/yellow boxes and its callout 1 (pixels (30,641)-(1218,1186)) replaced by a bilinear interpolation of the studio background sampled on the four sides of that rectangle plus 1 px gaussian grain (numpy, no inpainting model); nothing else changed; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "surgipulse_chen2024_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Rendering of the robotic positioning arm that carries the execution device",
     "source_key": "chen2024_firstinhuman",
     "source": "Chen et al., The International Journal of Cardiovascular Imaging (2024), graphical abstract panel B1, PMC11618145",
     "source_url": "https://doi.org/10.1007/s10554-024-03227-3",
     "where": "graphical abstract panel B1, PMC11618145",
     "licence": "CC BY-NC-ND 4.0"
    },
    {
     "id": "surgipulse_chen2024_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Doctor console with touch screen and joysticks beside the echo display",
     "source_key": "chen2024_firstinhuman",
     "source": "Chen et al., The International Journal of Cardiovascular Imaging (2024), graphical abstract panel B2, PMC11618145",
     "source_url": "https://doi.org/10.1007/s10554-024-03227-3",
     "where": "graphical abstract panel B2, PMC11618145",
     "licence": "CC BY-NC-ND 4.0"
    },
    {
     "id": "surgipulse_chen2024_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Rendering of the robotic host trolley",
     "source_key": "chen2024_firstinhuman",
     "source": "Chen et al., The International Journal of Cardiovascular Imaging (2024), graphical abstract panel B3, PMC11618145",
     "source_url": "https://doi.org/10.1007/s10554-024-03227-3",
     "where": "graphical abstract panel B3, PMC11618145",
     "licence": "CC BY-NC-ND 4.0"
    },
    {
     "id": "surgipulse_chen2024_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Three functional modules holding the guide, clip delivery catheter and clip sheath (boxed)",
     "source_key": "zhu2025_firstinman",
     "source": "Zhu et al., JACC: Cardiovascular Interventions (2025), Fig. 1(A) inset, p. 2",
     "source_url": "https://doi.org/10.1016/j.jcin.2025.01.437",
     "where": "Fig. 1(A) inset, p. 2",
     "licence": "publisher copyright"
    },
    {
     "id": "surgipulse_chen2024_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Execution device with the TEER instruments mounted, first-in-human case",
     "source_key": "chen2024_firstinhuman",
     "source": "Chen et al., The International Journal of Cardiovascular Imaging (2024), graphical abstract panel A2, PMC11618145 (previous main picture)",
     "source_url": "https://doi.org/10.1007/s10554-024-03227-3",
     "where": "graphical abstract panel A2, PMC11618145 (previous main picture)",
     "licence": "CC BY-NC-ND 4.0"
    }
   ],
   "sources": [
    {
     "key": "chen2024_firstinhuman",
     "doi": "10.1007/s10554-024-03227-3",
     "url": null,
     "title": "First-in-human robotic-assisted transcatheter mitral edge-to-edge repair for treatment of severe mitral regurgitation",
     "year": 2024,
     "venue": "The International Journal of Cardiovascular Imaging"
    },
    {
     "key": "zhu2025_firstinman",
     "doi": "10.1016/j.jcin.2025.01.437",
     "url": null,
     "title": "First-in-Man Study of Robotic-Assisted Transcatheter Edge-to-Edge Repair",
     "year": 2025,
     "venue": "JACC: Cardiovascular Interventions"
    }
   ],
   "read_level": "full",
   "read_level_detail": "partial (PMC HTML via WebFetch, chen2024_firstinhuman); full (zhu2025_firstinman)",
   "notes": "Company product; structural-heart scope; may belong in A4's commercial list. A telerobotic 8-case M-TEER series attributed to SurgiPulse appears in a 2025 EuroIntervention review (WebSearch snippet, not verified). | X2 2026-11-08: zhu2025 read in full: 9 patients, 3 devices driven at once. Clinical site corrected to Fuwai Yunnan Hospital (Kunming). The 2024 echo-guided first-in-man letter (Zhu 2024) and chen2024 both claim a first case; whether they describe the same patient is not stated.",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "csio_gupta2025",
   "name": "CSIO cardiac robot",
   "full_name": "CSIR-CSIO robot-assisted cardiac catheterization system",
   "group": "CSIR-Central Scientific Instruments Organisation and AcSIR (N. Gupta, R. Jha)",
   "group_short": "CSIR-CSIO",
   "family": "academic",
   "category": "academic",
   "first_year": 2025,
   "latest_year": 2025,
   "versions": "single report (gupta2025_hybrid)",
   "target_anatomy": "cardiac catheterization (bench)",
   "devices": [
    "catheter"
   ],
   "devices_driven": "catheter",
   "n_dof": 2,
   "n_dof_detail": "2 (translation + rotation)",
   "translation_mechanism": "other",
   "translation_detail": "other: roller-, gear- and belt-pulley mechanisms (abstract)",
   "rotation_mechanism": "other",
   "rotation_detail": "stepper-driven, 0.9 deg per pulse",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "spring-loaded force dynamics model; sensor N.R.",
   "haptics_leader": "surgeon-centric control panel for bidirectional manipulation",
   "imaging_compat": "N.R.",
   "sterility": "N.R.",
   "highest_validation": "bench",
   "validation_detail": "feed-forward PID tracking tests (gupta2025_hybrid abstract)",
   "key_numbers": "translation about 1 mm/s (0.060 rad/s), rotation 0.98 rad/s at 0.9 deg/pulse; displacement RMSE < 0.017 mm (R2 0.999), rotation RMSE < 0.11 deg, overshoot < 1% (gupta2025_hybrid abstract)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "photo",
    "source": "gupta2025_design Fig. 2(b) (prototype photo), IEEE T-MRB 7(1) 2025, doi:10.1109/TMRB.2024.3503911",
    "source_url": "https://doi.org/10.1109/TMRB.2024.3503911",
    "licence": "publisher copyright (IEEE)",
    "credit": "Gupta et al., IEEE Transactions on Medical Robotics and Bionics (2025), Fig. 2(b). publisher copyright (IEEE).",
    "edits": "native extract (2717 x 3455); cropped to panel (b) without the panel letter and the bottom label row; label text lying on the plain white background painted white (9 rectangles, no inpainting model); not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "csio_gupta2025_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Top view of both drives feeding a catheter into arterial replicas",
     "source_key": "gupta2025_design",
     "source": "Gupta et al., IEEE Transactions on Medical Robotics and Bionics (2025), Fig. 11, p. 9",
     "source_url": "https://doi.org/10.1109/tmrb.2024.3503911",
     "where": "Fig. 11, p. 9",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "csio_gupta2025_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Axial drive: spring-loaded roller pairs and gear train gripping the catheter",
     "source_key": "gupta2025_catheter",
     "source": "Gupta et al., 2025 International Conference on Innovation and Intelligence for Informatics, Computing, and Technologies (3ICT) (2025), Fig. 3, p. 3",
     "source_url": "https://doi.org/10.1109/3ict68299.2025.11442127",
     "where": "Fig. 3, p. 3",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "csio_gupta2025_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Rotational drive with its cover on, top view",
     "source_key": "gupta2025_catheter",
     "source": "Gupta et al., 2025 International Conference on Innovation and Intelligence for Informatics, Computing, and Technologies (3ICT) (2025), Fig. 2, p. 3",
     "source_url": "https://doi.org/10.1109/3ict68299.2025.11442127",
     "where": "Fig. 2, p. 3",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "csio_gupta2025_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Labelled CAD drawing of the two-drive catheter robot",
     "source_key": "gupta2025_design",
     "source": "Gupta et al., IEEE Transactions on Medical Robotics and Bionics (2025), Fig. 2(a), p. 4",
     "source_url": "https://doi.org/10.1109/tmrb.2024.3503911",
     "where": "Fig. 2(a), p. 4",
     "licence": "publisher copyright (IEEE)"
    }
   ],
   "sources": [
    {
     "key": "gupta2025_hybrid",
     "doi": "10.1177/09544119251385276",
     "url": null,
     "title": "Hybrid control algorithm for precision motion in robot-assisted cardiac catheterization",
     "year": 2025,
     "venue": "Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine"
    }
   ],
   "read_level": "abstract",
   "read_level_detail": "abstract",
   "notes": "",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "shibaura_zakaria2012",
   "name": "Foolproof guide",
   "full_name": "Shibaura Institute of Technology tele-operated foolproof catheter guide system (ER-fluid master, roller slave)",
   "group": "Shibaura Institute of Technology, Research Organization for Advanced Engineering (Takashi Komeda) with Universiti Teknologi MARA (Noor Ayuni Che Zakaria, Cheng Yee Low, Ahmad Yusri Ismail), M. D. Mohri Hospital (Mohri Makoto) and Fraunhofer Institute for Production Technology (Roman Dumitrescu)",
   "group_short": "Shibaura IT",
   "family": "academic",
   "category": "academic",
   "first_year": 2012,
   "latest_year": 2012,
   "versions": "single prototype (Prod. Eng. Res. Devel. 7:81-90; online 20 Nov 2012, issue dated 2013)",
   "target_anatomy": "interventional radiology catheterisation (vessel not specified)",
   "devices": [
    "catheter"
   ],
   "devices_driven": "catheter, \"compliant with catheter sizes 3-11 Fr\" (Sec. 8)",
   "n_dof": 2,
   "n_dof_detail": "2 (thrust and rotation) on the slave and on the master (Sec. 8)",
   "translation_mechanism": "other",
   "translation_detail": "other: \"passive roller as thrust mechanism while holding the catheter\", rubber with a high friction coefficient; stepping motor, DC motor and slide rail labelled in Fig. 9, their roles not stated (Sec. 8)",
   "rotation_mechanism": "rotating-drive-unit",
   "rotation_detail": "rotation of the slave housing about the catheter axis (Fig. 9 \"Rotation movement\"); actuator N.R.",
   "device_range": "3-11 Fr (Sec. 8)",
   "footprint_mm": "N.R. (\"lightweight, compact\", Sec. 8)",
   "mass_kg": "N.R.",
   "force_sensing": "claimed but not shown: \"It is installed with a force sensor to enable haptic feedback\" and \"For future work, force sensors will be attached to the slave robot\" (Sec. 8); design threshold: contact force above 0.12 N is treated as a collision (Sec. 6)",
   "haptics_leader": "master tool with 2 DOF (thrust on a sliding screw and bearing, rotation) and electro-rheological (ER) fluid as a passive actuator that stiffens when force is detected (Sec. 8); not demonstrated",
   "imaging_compat": "N.R. (concept: DSA, surgeon in a separate control room, Fig. 1)",
   "sterility": "requirement only: \"the parts of the catheter must be sterilizable\" (Sec. 8)",
   "highest_validation": "bench",
   "validation_detail": "initial thrust and rotation tracking of the slave following the master; no phantom, trial counts N.R. (Sec. 8, Figs. 10-11)",
   "key_numbers": "rotation tracking error < 1 deg with time delay < 10 ms; thrust tracking shows \"1:5 distance differences\" and a tracking error in the second stroke (Sec. 8); design limits: translational velocity below 10 mm/s, collision threshold 0.12 N (Sec. 6)",
   "sim_model": "none found (control software in MATLAB Simulink; system specified in CONSENS)",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "photo",
    "source": "zakaria2012_development Fig. 9 (slave robot photo, top left of the figure), Prod. Eng. Res. Devel. 7:81-90, doi:10.1007/s11740-012-0430-6; native raster p. 8 (228 x 152)",
    "source_url": "https://doi.org/10.1007/s11740-012-0430-6",
    "licence": "publisher copyright",
    "credit": "Che Zakaria et al., Production Engineering (2012), Fig. 9. publisher copyright.",
    "edits": "native extract; cropped to drop the orange thrust arrow at the left (two small cyan rotation-arrow marks on the bracket remain); not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "shibaura_zakaria2012_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Slave roller unit: stepping motor, roller, slide rail and DC motor",
     "source_key": "zakaria2012_development",
     "source": "Che Zakaria et al., Production Engineering (2012), Fig. 9 (bottom), p. 8",
     "source_url": "https://doi.org/10.1007/s11740-012-0430-6",
     "where": "Fig. 9 (bottom), p. 8",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "zakaria2012_development",
     "doi": "10.1007/s11740-012-0430-6",
     "url": null,
     "title": "Development of foolproof catheter guide system based on mechatronic design",
     "year": 2012,
     "venue": "Production Engineering"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (zakaria2012_development, 2026-10-14)",
   "notes": "Added by F4 2026-10-14 from the A8 title-only lead (snowball via li2024_review). Mostly a CONSENS design-methodology paper; the prototype is a 2-DoF master-slave with bench tracking only. Surname is Che Zakaria (bib key zakaria2012_development). Not in S8_systems.csv.",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "shu_li2018",
   "name": "SHU friction-wheel",
   "full_name": "Shanghai University master-slave vascular interventional surgery robot (friction-wheel slave, catheter-handling master)",
   "group": "Shanghai University, School of Mechatronic Engineering and Automation, Shanghai Key Laboratory of Intelligent Manufacturing and Robotics (Long Li, Zhihui Huang, Yingzhong Tian, Zexi Li) with Shenzhen Polytechnic (Wenbin Wang, Wei Chen) and Ryerson University (Fengfeng Xi)",
   "group_short": "Shanghai U.",
   "family": "academic",
   "category": "academic",
   "first_year": 2018,
   "latest_year": 2018,
   "versions": "2018 IEEE ROBIO prototype (li2018_design, doi:10.1109/ROBIO.2018.8664841); title only in a page-1 render (the text layer has no title)",
   "target_anatomy": "general vascular intervention; no anatomy tested (li2018_design Sec. I-II)",
   "devices": [
    "guidewire",
    "catheter"
   ],
   "devices_driven": "one catheter or guidewire (Sec. II); bench tests drove a catheter (Sec. III)",
   "n_dof": 2,
   "n_dof_detail": "2 (axial, circumferential) (Sec. II-C)",
   "translation_mechanism": "friction-roller",
   "translation_detail": "friction-roller: stepper motor 1 turns friction wheel 1; a spring clamping device presses the two wheels on the device (Sec. II-C, Figs. 3-4)",
   "rotation_mechanism": "other",
   "rotation_detail": "stepper motor 2 drives a ball screw that slides friction wheel 2 sideways, rolling the device in the groove of wheel 1 (Sec. II-C, Fig. 3(b))",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "force detection at the catheter front end and a force-feedback device at the master are part of the system architecture (Sec. II-A, Fig. 1); not evaluated",
   "haptics_leader": "custom master: the operator moves a real catheter between two spring-pressed friction wheels read by an encoder (axial) and turns an operating tube on a rotary encoder (rotation); force-feedback device described, not evaluated (Sec. II-A-B, Fig. 2)",
   "imaging_compat": "N.R. (DSA appears only in the architecture drawing, Fig. 1)",
   "sterility": "N.R.",
   "highest_validation": "bench",
   "validation_detail": "bench accuracy only: master inputs of 2, 5, 8, 10, 20 mm and 20, 45, 60, 90, 120 deg, 10 repeats each, slave output measured with an infrared range sensor and a light spot; several master-slave ratios (Sec. III-IV, Figs. 5-6, Tables I-III)",
   "key_numbers": "position accuracy 0.17-0.60 mm (repeatability 0.07-0.14 mm) over 2-20 mm; angle accuracy 0.27-0.88 deg (repeatability 0.10-0.18 deg) over 20-120 deg (Tables I-II)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "render",
    "source": "li2018_design Fig. 4 (structure of slave manipulator), p. 178, IEEE ROBIO 2018 doi:10.1109/ROBIO.2018.8664841",
    "source_url": "https://doi.org/10.1109/ROBIO.2018.8664841",
    "licence": "publisher copyright (IEEE)",
    "credit": "Li et al., 2018 IEEE International Conference on Robotics and Biomimetics (ROBIO) (2018), Fig. 4. publisher copyright (IEEE).",
    "edits": "page region rendered at the embedded strips' native scale (3.32 px/pt, 239 dpi; the figure is stored as ten 714 px strips plus vector labels); caption excluded; nothing erased; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "shu_li2018_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Displacement-accuracy bench: master and slave with the catheter drive device",
     "source_key": "li2018_design",
     "source": "Li et al., 2018 IEEE International Conference on Robotics and Biomimetics (ROBIO) (2018), Fig. 5(a)-(b), p. 179",
     "source_url": "https://doi.org/10.1109/robio.2018.8664841",
     "where": "Fig. 5(a)-(b), p. 179",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "shu_li2018_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Angle-accuracy bench: slave manipulator with infrared range sensor and light spot",
     "source_key": "li2018_design",
     "source": "Li et al., 2018 IEEE International Conference on Robotics and Biomimetics (ROBIO) (2018), Fig. 6(a)-(b), p. 179",
     "source_url": "https://doi.org/10.1109/robio.2018.8664841",
     "where": "Fig. 6(a)-(b), p. 179",
     "licence": "publisher copyright (IEEE)"
    }
   ],
   "sources": [
    {
     "key": "li2018_design",
     "doi": "10.1109/robio.2018.8664841",
     "url": null,
     "title": "Design and Performance Evaluation of a Novel Vascular Interventional Surgery Robot",
     "year": 2018,
     "venue": "2018 IEEE International Conference on Robotics and Biomimetics (ROBIO)"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (li2018_design,; text decoded per font, title from a page-1 render)",
   "notes": "2026-11-08 X3: new row from the hand-downloaded ROBIO 2018 paper. Different group from tianjin_song2023 (Tianjin Univ. of Technology) although both use an encoder-read real catheter as the master handle. No later paper of this robot found in lit/ (grep 'Yingzhong Tian')",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "insa_naudin2019",
   "name": "EVAR platform",
   "full_name": "INSA Lyon / Ampère low-cost robotic platform for endovascular aneurysm repair (EVAR): two stacked conveyors pinch the guidewire, an X-Y table rolls it, simulation-driven haptic leader",
   "group": "Laboratoire Ampère (UMR CNRS 5005), Université de Lyon, INSA Lyon (Iris Naudin, Minh Tu Pham, Richard Moreau, Arnaud Lelevé) (naudin2019_evar, affiliation line)",
   "group_short": "INSA Lyon",
   "family": "academic",
   "category": "academic",
   "first_year": 2019,
   "latest_year": 2019,
   "versions": "single version (naudin2019_evar, AIM 2019); its finite-element model of guide insertion comes from the INSA thesis of G. Mouktadiri 2012 and Mouktadiri et al., J. Biomed. Sci. Eng. 2013 (refs 5-6, not read)",
   "target_anatomy": "abdominal aorta and iliac arteries (EVAR of an abdominal aortic aneurysm); patient-specific silicone phantom printed by additive manufacturing, spring-suspended in a water tank (Sec. II, III-A, Fig. 6)",
   "devices": [
    "guidewire",
    "catheter"
   ],
   "devices_driven": "guidewire (\"guide\"); \"it is also possible to drive a catheter by this system instead of a guide wire\"; one device at a time (Sec. III-A)",
   "n_dof": 2,
   "n_dof_detail": "2 device DOF (translation along z, rotation about z) plus a prismatic gap adjustment (y) that sets the conveyor spacing for the device diameter (Sec. III-A, Fig. 3)",
   "translation_mechanism": "belt/track",
   "translation_detail": "belt/track: two conveyors placed one over the other pinch the guidewire, each driven by a DC motor, coupled so they turn in opposite directions (Sec. III-A, IV-A, Figs. 3-4)",
   "rotation_mechanism": "other",
   "rotation_detail": "other: an X-Y table translates one conveyor over the other, rolling the pinched wire about its own axis (cylindrical joint S1-S2; Sec. III-A, Figs. 3, 5)",
   "device_range": "N.R. (conveyor gap adjustable \"to use guide wires with different diameters\", Sec. III-A)",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "none on the robot; the force sent to the leader is the guide-aorta contact force of an ABAQUS simulation, looked up by inserted length (Sec. III-C, IV-B); the authors state it is not the force at the tool (Sec. V)",
   "haptics_leader": "Geomagic Touch (6 DOF, 3 motorised); pressing a stylus button acts as pinching the guide (clutch), stylus translation and rotation are sent to the conveyors and the X-Y table; renders the simulated contact force opposite to the push (Sec. III-A, III-C, Fig. 7)",
   "imaging_compat": "N.R. (no fluoroscopy in the platform; phantom in a transparent water tank)",
   "sterility": "N.R.",
   "highest_validation": "bench",
   "validation_detail": "bench: conveyor translation tracking of the stylus reference trajectory with a proportional speed loop (Simulink/ControlDesk, Fig. 14) and recording of the rotation reference (Sec. IV-A); haptic lookup coupled to the platform (Sec. IV-B). The silicone aorta phantom is built for guide insertion but no insertion result is reported; real-time control was not achieved with MATLAB/Simulink/dSPACE and was re-written in C afterwards (Sec. V). Alekseeva 2025 Table 4 lists it as TRL3 (ex vivo phantom).",
   "key_numbers": "motor speed command 0-10 V, direction 0/5 V (Sec. IV-A); simulated insertion speed 20 mm/s (Sec. IV-B); exit of contact for an arbitrary 90 deg rotation (Sec. V); tracking error shown only as a curve x10 (Fig. 14), no number reported (N.R.)",
   "sim_model": "yes: ABAQUS finite-element model of the guide inserted in a patient aorta and iliac model (elastic, hyperelastic and linear composite materials; Mouktadiri 2013, ref 6) gives contact forces per inserted length, used as the haptic lookup table (naudin2019_evar Sec. III-B, IV-B, Fig. 8)",
   "has_sim_model": true,
   "sim2real": "none-found",
   "sim2real_detail": "none found (the simulation feeds an offline force lookup; no simulation-trained controller)",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "photo",
    "source": "naudin2019_evar Fig. 4 (two conveyors), p. 3",
    "source_url": "https://doi.org/10.1109/AIM.2019.8868919",
    "licence": "publisher copyright (IEEE)",
    "credit": "Naudin et al., 2019 IEEE/ASME International Conference on Advanced Intelligent Mechatronics (AIM) (2019), Fig. 4. publisher copyright (IEEE).",
    "edits": "native extract; no crop; no edit; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "insa_naudin2019_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Top view of the X-Y table that shifts one conveyor to roll the wire",
     "source_key": "naudin2019_evar",
     "source": "Naudin et al., 2019 IEEE/ASME International Conference on Advanced Intelligent Mechatronics (AIM) (2019), Fig. 5, p. 3",
     "source_url": "https://doi.org/10.1109/AIM.2019.8868919",
     "where": "Fig. 5, p. 3",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "insa_naudin2019_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Silicone aorta and iliac phantom suspended in a water tank",
     "source_key": "naudin2019_evar",
     "source": "Naudin et al., 2019 IEEE/ASME International Conference on Advanced Intelligent Mechatronics (AIM) (2019), Fig. 6, p. 3",
     "source_url": "https://doi.org/10.1109/AIM.2019.8868919",
     "where": "Fig. 6, p. 3",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "insa_naudin2019_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Geomagic Touch haptic device used as the leader, with joint labels",
     "source_key": "naudin2019_evar",
     "source": "Naudin et al., 2019 IEEE/ASME International Conference on Advanced Intelligent Mechatronics (AIM) (2019), Fig. 7, p. 3 (image credited to Geomagic)",
     "source_url": "https://doi.org/10.1109/AIM.2019.8868919",
     "where": "Fig. 7, p. 3 (image credited to Geomagic)",
     "licence": "publisher copyright (IEEE)"
    }
   ],
   "sources": [
    {
     "key": "naudin2019_evar",
     "doi": "10.1109/AIM.2019.8868919",
     "url": null,
     "title": "A Robotic Platform For Endovascular Aneurysm Repair",
     "year": 2019,
     "venue": "2019 IEEE/ASME International Conference on Advanced Intelligent Mechatronics (AIM)"
    },
    {
     "key": "alekseeva2025_design",
     "doi": "10.1002/rob.22480",
     "url": null,
     "title": "The Design of Endovascular Robots for Cardiac Interventions: A Survey",
     "year": 2024,
     "venue": "Journal of Field Robotics"
    },
    {
     "key": "belikov2024_evolution",
     "doi": "10.1016/j.jestch.2024.101789",
     "url": null,
     "title": "Evolution and current state of robotic catheters for endovascular surgery: A comprehensive review",
     "year": 2024,
     "venue": "Engineering Science and Technology, an International Journal"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (naudin2019_evar); review-only (alekseeva2025_design Table 4 row 1; belikov2024_evolution Fig. 6 NA)",
   "notes": "N2 2026-11-08, from review_comparison §1.2 row 23. Built as a low-cost teaching and trajectory-planning platform for EVAR (Abstract, Sec. I). Alekseeva Fig. 12c draws only its rolling-belt principle. Highest validation is bench, not phantom as Alekseeva says: the phantom exists, but no result in it is reported.",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "ujn_cao2024",
   "name": "UJN catheter drive",
   "full_name": "University of Jinan compact continuous-delivery catheter drive with friction wheels in a disposable surgical box and a constant-force clamp",
   "group": "School of Mechanical Engineering, University of Jinan (Tianxiao Cao, Rongyu Ge [corresponding], Yi Zhang, Wenlong Wang) (cao2024_cathdrive, affiliation lines)",
   "group_short": "U. of Jinan",
   "family": "academic",
   "category": "academic",
   "first_year": 2024,
   "latest_year": 2024,
   "versions": "single version (cao2024_cathdrive, IDITR 2024); Alekseeva 2025 Table 10 lists a design by the same authors (W. Wang et al. 2024, clamping bracket block) as TRL2 concept, not catalogued",
   "target_anatomy": "N.R. (general vascular intervention; coronary, brain, liver and kidney lesions named in the introduction)",
   "devices": [
    "catheter"
   ],
   "devices_driven": "one catheter (Sec. II); tests with a catheter (Figs. 13-14)",
   "n_dof": 2,
   "n_dof_detail": "2 (axial feed, circumferential rotation) (Sec. II)",
   "translation_mechanism": "friction-roller",
   "translation_detail": "friction-roller: two active and two driven grooved friction wheels in a disposable box, the active ones driven through three gear shafts by one motor; the box couples to the power unit by a triangular-prism shaft (Sec. II-A1, II-B, Figs. 2, 4, 7)",
   "rotation_mechanism": "rotating-drive-unit",
   "rotation_detail": "gear pair rotates the whole axial-feed unit, the feed motor rides along, wires through a conductive slip ring (Sec. II-A2, Fig. 3)",
   "device_range": "N.R. (constant-force clamp adjustable by spring pre-compression, Sec. II-B, III)",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "none (a sawtooth constant-force clamp caps the clamping force mechanically, Sec. II-B, III)",
   "haptics_leader": "a \"master manipulator\" box stands on the bench in the platform photo (Fig. 12); its design is N.R.; the tests were run from upper-computer software (Sec. V)",
   "imaging_compat": "N.R.",
   "sterility": "disposable surgical box holds every part that touches the catheter; reusable power unit below (Sec. II-B, Fig. 5)",
   "highest_validation": "bench",
   "validation_detail": "bench: 10 axial moves of 100 mm measured with a vernier caliper and 10 rotations of 60 deg measured with a protractor on the experimental platform (Sec. V, Figs. 12-14); no phantom. Alekseeva 2025 Table 9 lists it as TRL3 (ex vivo phantom).",
   "key_numbers": "axial error -0.65 to +0.62 mm per 100 mm move; rotation error -2 to +2 deg per 60 deg (Sec. V); calculated: 19.72 mm per feed-motor turn, max feed speed 3845.39 mm/s, 0.05 rad per rotation-motor turn, max rotation speed printed as 6.42 rad/s in Eq. 11 and 6.24 rad/s in the text (Sec. IV); friction wheel radius 14.5 mm; feed motor 11,700 rpm with reducer 4.62; rotation motor 7,600 rpm with reducer 62.01 and gear ratio 2:1 (Sec. IV)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "render",
    "source": "cao2024_cathdrive Fig. 1 overall CAD diagram, p. 2",
    "source_url": "https://doi.org/10.1109/IDITR62018.2024.10554319",
    "licence": "publisher copyright (IEEE)",
    "credit": "Cao et al., 2024 3rd International Conference on Innovations and Development of Information Technologies and Robotics (IDITR) (2024), Fig. 1. publisher copyright (IEEE).",
    "edits": "native extract; cropped off the label row and leader lines (box 0,84,620,480); two dashed red group boxes remain across the model; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "ujn_cao2024_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Bench platform with PCs, master manipulator, drive and power supply (labelled)",
     "source_key": "cao2024_cathdrive",
     "source": "Cao et al., 2024 3rd International Conference on Innovations and Development of Information Technologies and Robotics (IDITR) (2024), Fig. 12, p. 6 (rendered at 300 dpi)",
     "source_url": "https://doi.org/10.1109/IDITR62018.2024.10554319",
     "where": "Fig. 12, p. 6 (rendered at 300 dpi)",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "ujn_cao2024_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Rotation test of the prototype gear with a protractor, two positions",
     "source_key": "cao2024_cathdrive",
     "source": "Cao et al., 2024 3rd International Conference on Innovations and Development of Information Technologies and Robotics (IDITR) (2024), Fig. 14, p. 6",
     "source_url": "https://doi.org/10.1109/IDITR62018.2024.10554319",
     "where": "Fig. 14, p. 6",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "ujn_cao2024_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Axial feed test of the catheter measured with a vernier caliper",
     "source_key": "cao2024_cathdrive",
     "source": "Cao et al., 2024 3rd International Conference on Innovations and Development of Information Technologies and Robotics (IDITR) (2024), Fig. 13, p. 6",
     "source_url": "https://doi.org/10.1109/IDITR62018.2024.10554319",
     "where": "Fig. 13, p. 6",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "ujn_cao2024_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD section of the disposable surgical box on its motor base",
     "source_key": "cao2024_cathdrive",
     "source": "Cao et al., 2024 3rd International Conference on Innovations and Development of Information Technologies and Robotics (IDITR) (2024), Fig. 5(a), p. 3",
     "source_url": "https://doi.org/10.1109/IDITR62018.2024.10554319",
     "where": "Fig. 5(a), p. 3",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "ujn_cao2024_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD of the gear-driven circumferential rotation structure",
     "source_key": "cao2024_cathdrive",
     "source": "Cao et al., 2024 3rd International Conference on Innovations and Development of Information Technologies and Robotics (IDITR) (2024), Fig. 3, p. 3",
     "source_url": "https://doi.org/10.1109/IDITR62018.2024.10554319",
     "where": "Fig. 3, p. 3",
     "licence": "publisher copyright (IEEE)"
    }
   ],
   "sources": [
    {
     "key": "cao2024_cathdrive",
     "doi": "10.1109/IDITR62018.2024.10554319",
     "url": null,
     "title": "Design of Catheter Drive Mechanism for Vascular Interventional Surgery Robot",
     "year": 2024,
     "venue": "2024 3rd International Conference on Innovations and Development of Information Technologies and Robotics (IDITR)"
    },
    {
     "key": "alekseeva2025_design",
     "doi": "10.1002/rob.22480",
     "url": null,
     "title": "The Design of Endovascular Robots for Cardiac Interventions: A Survey",
     "year": 2024,
     "venue": "Journal of Field Robotics"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (cao2024_cathdrive); review-only (alekseeva2025_design Table 9 row 5)",
   "notes": "N2 2026-11-08, from review_comparison §1.2 row 26. Main picture is CAD: the only prototype photo (Fig. 12, platform) shows the drive about 200 px wide inside a red box; that photo is gallery picture 01. Alekseeva Fig. 12(a,b) draws the generic roller principle only.",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "bupt_yang2022",
   "name": "BUPT guidewire robot",
   "full_name": "BUPT guidewire feeding robot (friction-wheel push-pull, gear rotation) used for deep-RL guidewire feeding on a vessel phantom",
   "group": "Beijing University of Posts and Telecommunications, School of Automation (Deai Yang, Jingzhou Song, Yuhang Hu) (yang2022_guidewire p. 1287; Crossref affiliations)",
   "group_short": "BUPT",
   "family": "academic",
   "category": "academic",
   "first_year": 2022,
   "latest_year": 2022,
   "versions": "single paper (yang2022_guidewire, ICMA 2022); the robot is described only in its Sec. IV-A",
   "target_anatomy": "abdominal-aorta target in a vessel phantom with pumped water at a controlled temperature (Sec. IV-A, IV-C, Figs. 1-2, 7); detection images from the phantom's femoral artery and aortic arch (Sec. IV-B)",
   "devices": [
    "guidewire"
   ],
   "devices_driven": "one guidewire (type N.R.)",
   "n_dof": 2,
   "n_dof_detail": "2: push-pull and rotation, decoupled (Sec. IV-A)",
   "translation_mechanism": "friction-roller",
   "translation_detail": "friction-roller: 'It moves the guidewire forward or backward via a pair of friction wheels clamping it' (Sec. IV-A)",
   "rotation_mechanism": "other",
   "rotation_detail": "'The rotation of the guidewire around the central axis is achieved by a pair of rotating gears' (Sec. IV-A)",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "none (force from the motor current proposed as future work, Sec. V)",
   "haptics_leader": "none: an autonomous SAC agent on a server sends (push-pull, rotation) actions (Sec. IV-A, Fig. 2)",
   "imaging_compat": "camera above the transparent phantom; the YOLOv5s tip detector was also run on angiographic images (Fig. 5); fluoroscopy with the robot N.R.",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "phantom: two training-and-test experiments on the physical phantom, (1) push-pull only, 500 episodes of <= 150 steps in 2.5 h, converged after about 260 episodes; (2) push-pull plus rotation, 500 episodes in 4.2 h, converged after about 300; test runs reached the target within the 40-pixel (about 5 mm) termination criterion (Sec. IV-C, Figs. 8-13). Number of test runs N.R.",
   "key_numbers": "push-pull accuracy 1 mm, rotation accuracy 5 deg (Sec. IV-A); action limits +/-20 mm, +/-90 deg (Sec. III-A); feeding error < 5 mm, tip detection >= 92.9 % (Abstract); YOLOv5s 23 ms per image (Sec. IV-B)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found: the policy is trained on the physical phantom without a simulator ('To avoid the error caused by the virtual simulation environment, we built an interventional surgery experimental platform based on vessel phantom', Sec. IV-A)",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "photo",
    "source": "yang2022_guidewire Fig. 1 (experimental platform), right part, p. 4",
    "source_url": "https://doi.org/10.1109/icma54519.2022.9856351",
    "licence": "publisher copyright (IEEE)",
    "credit": "Yang et al., 2022 IEEE International Conference on Mechatronics and Automation (ICMA) (2022), Fig. 1. publisher copyright (IEEE).",
    "edits": "native embedded raster (727 x 456) cropped to the robot (box 498,195,727,378); tip of the red pointer of the 'guidewire feeding robot' label remains at the lower left; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "bupt_yang2022_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Guidewire feeding robot beside the vessel phantom, camera, pump and thermostat",
     "source_key": "yang2022_guidewire",
     "source": "Yang et al., 2022 IEEE International Conference on Mechatronics and Automation (ICMA) (2022), Fig. 1, p. 4",
     "source_url": "https://doi.org/10.1109/icma54519.2022.9856351",
     "where": "Fig. 1, p. 4",
     "licence": "publisher copyright (IEEE)"
    }
   ],
   "sources": [
    {
     "key": "yang2022_guidewire",
     "doi": "10.1109/icma54519.2022.9856351",
     "url": null,
     "title": "Guidewire feeding method based on deep reinforcement learning for vascular intervention robot",
     "year": 2022,
     "venue": "2022 IEEE International Conference on Mechatronics and Automation (ICMA)"
    },
    {
     "key": "konda2025_robotically",
     "doi": "10.1126/scirobotics.adt7461",
     "url": null,
     "title": "Robotically steerable guidewires—Current trends and future directions",
     "year": 2025,
     "venue": "Science Robotics"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full",
   "notes": "N3 2026-11-08, from review_comparison Sec. 1.3 (Konda 2025 control row 37, ref. 129, one of the 'learning-only controllers'). The controller ran on this physical robot, so the robot itself is catalogued. No other paper describing the robot was found. Picture is 229 px wide and carries the tip of a red pointer: the robot is about a third of the 727 px setup photo.",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "cstar_activecath_jayender2006",
   "name": "CSTAR active catheter",
   "full_name": "CSTAR robot-assisted active-catheter insertion test bed (7-DOF PA10-7C arm inserting an SMA-actuated catheter)",
   "group": "Western University / Canadian Surgical Technologies and Advanced Robotics (CSTAR) (R. V. Patel; J. Jayender, M. Azizian) with NRC Integrated Manufacturing Technologies Institute (S. Nikumb, SMA micro-welding)",
   "group_short": "Western / CSTAR",
   "family": "academic",
   "category": "academic",
   "first_year": 2006,
   "latest_year": 2009,
   "versions": "2006 ICRA hybrid impedance (force/position) control of catheter insertion by a 7-DOF redundant robot with proximal force sensing (title; rafiitari2014_current Sec. Robotic platforms); 2007 IROS autonomous insertion with image guidance (title); 2008 TRO autonomous image-guided insertion (full); 2008 BioRob wave-variable bilateral teleoperation of the active catheter (title); 2009 IJRR augmented hybrid impedance control + master-slave SMA tip control (full, jayender2009_robot)",
   "target_anatomy": "vascular/angioplasty access (vinyl-tube vessel test bed); PCI-size (5 Fr) catheters as motivation",
   "devices": [
    "catheter"
   ],
   "devices_driven": "one 5 Fr guide catheter (Medtronic) instrumented with SMA actuators: three SMA wires at 120 deg, several sections (TRO 2008 Sec. II, VII)",
   "n_dof": 7,
   "n_dof_detail": "7 (Mitsubishi PA10-7C arm) plus SMA tip bending (yaw and pitch)",
   "translation_mechanism": "other",
   "translation_detail": "other: 7-DOF industrial arm (Mitsubishi PA10-7C) inserts the catheter in strokes whose length is set from image feedback",
   "rotation_mechanism": "other",
   "rotation_detail": "arm wrist (catheter roll use N.R.); tip steering by SMA actuators",
   "device_range": "one 5 Fr catheter",
   "footprint_mm": "N.R. (industrial arm)",
   "mass_kg": "N.R.",
   "force_sensing": "ATI Gamma 6-DOF wrist force/torque sensor regulates insertion force (TRO 2008 Sec. II)",
   "haptics_leader": "none in TRO 2008 (clinician sets start and target in a GUI); IJRR 2009: Phantom Omni gives yaw/pitch references for the SMA tip (closed loop on an NDI Aurora tip sensor, 30 Hz) and the user sets the insertion stroke (Sec. 3.2, 5.4, Fig. 4); bilateral wave-variable teleoperation in BioRob 2008 (title only)",
   "imaging_compat": "camera images of the test bed as X-ray stand-in (about 1.0 mm/pixel) plus 5-DOF NDI Aurora EM sensor at the tip (TRO 2008 Sec. II-III)",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "autonomous insertion through a vinyl-tube test bed with tubes of 3.0, 4.5 and 6.0 mm internal diameter and two bifurcations (second at a random 3-D angle) (TRO 2008 Sec. II, VIII); IJRR 2009: position, force, and force+moment control runs in the 3.0 mm tube, then a teleoperated run through two active branches (left, then right) with SMA bending at each junction (Sec. 5, Figs. 7-20)",
   "key_numbers": "arm Cartesian tracking RMS 0.27/0.30/0.43 mm (x/y/z) and 0.18/0.06/0.17 deg; force tracking RMS 0.05 N; host-arm loop 333 Hz; EM sensor RMS 0.9-1.3 mm (TRO 2008 Sec. II, VI); insertion force regulated at 0.25 N, never exceeded through two active branches (IJRR 2009 Sec. 5.4, Fig. 20)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "photo",
    "source": "jayender2006_impedance_ICRA Fig. 2 'Testbed for catheter insertion' (photo, p. 3), ICRA 2006",
    "source_url": "https://doi.org/10.1109/robot.2006.1641777",
    "licence": "publisher copyright (IEEE)",
    "credit": "Jayender et al., Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. ICRA 2006. (), Fig. 2. publisher copyright (IEEE).",
    "edits": "native extract (1024x743); no crop; no erasing; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "cstar_activecath_jayender2006_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "PA10-7C arm inserting the active catheter into the planar vessel test bed",
     "source_key": "jayender2007_autonomous",
     "source": "jayender2007_autonomous, Fig. 8, p. 5",
     "source_url": null,
     "where": "Fig. 8, p. 5",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "cstar_activecath_jayender2006_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Unlabelled view of the arm, catheter gripper and vessel-network test bed",
     "source_key": "jayender2006_robot",
     "source": "Jayender et al., Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. ICRA 2006. (), Fig. 2, p. 3",
     "source_url": "https://doi.org/10.1109/robot.2006.1641777",
     "where": "Fig. 2, p. 3",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "cstar_activecath_jayender2006_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "SMA-actuated active catheter tip shown at successive bending angles",
     "source_key": "jayender2008_autonomous",
     "source": "Jayender et al., IEEE Transactions on Robotics (2008), Fig. 11, p. 8",
     "source_url": "https://doi.org/10.1109/tro.2008.2001353",
     "where": "Fig. 11, p. 8",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "cstar_activecath_jayender2006_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "SMA wires laser-microwelded to stainless-steel pads at the catheter tip",
     "source_key": "jayender2008_autonomous",
     "source": "Jayender et al., IEEE Transactions on Robotics (2008), Fig. 12, p. 8",
     "source_url": "https://doi.org/10.1109/tro.2008.2001353",
     "where": "Fig. 12, p. 8",
     "licence": "publisher copyright (IEEE)"
    }
   ],
   "sources": [
    {
     "key": "jayender2008_autonomous",
     "doi": "10.1109/tro.2008.2001353",
     "url": null,
     "title": "Autonomous Image-Guided Robot-Assisted Active Catheter Insertion",
     "year": 2008,
     "venue": "IEEE Transactions on Robotics"
    },
    {
     "key": "jayender2006_robot",
     "doi": "10.1109/robot.2006.1641777",
     "url": null,
     "title": "Robot-assisted catheter insertion using hybrid impedance control",
     "year": null,
     "venue": "Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. ICRA 2006."
    },
    {
     "key": "jayender2008_wave",
     "doi": "10.1109/biorob.2008.4762778",
     "url": null,
     "title": "Wave variables based bilateral teleoperation of an active catheter",
     "year": 2008,
     "venue": "2008 2nd IEEE RAS &amp; EMBS International Conference on Biomedical Robotics and Biomechatronics"
    },
    {
     "key": "jayender2009_robot",
     "doi": "10.1177/0278364909103785",
     "url": null,
     "title": "Robot-assisted Active Catheter Insertion: Algorithms and Experiments",
     "year": 2009,
     "venue": "The International Journal of Robotics Research"
    },
    {
     "key": "rafiitari2014_current",
     "doi": "10.1007/s10439-013-0946-8",
     "url": null,
     "title": "Current and Emerging Robot-Assisted Endovascular Catheterization Technologies: A Review",
     "year": 2014,
     "venue": "Annals of Biomedical Engineering"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (TRO 2008; IJRR 2009, ); title/secondary for 2006, 2007, 2008 BioRob",
   "notes": "General-purpose industrial arm used as the inserter; the contribution is the SMA active catheter with force/position control. | 2026-11-08 X3: IJRR 2009 read in full; its two hardware figures (Fig. 7 test bed, Fig. 2 micro-welded SMA tip) repeat pictures already in the gallery (_01 IROS 2007 Fig. 8, _04 TRO 2008 Fig. 12), so no gallery addition",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "cstar_ablation_khoshnam2014",
   "name": "CSTAR ablation robot",
   "full_name": "CSTAR robotics-assisted ablation-catheter manipulation system (pull-wire drive with tension sensing and model-based contact-force estimation)",
   "group": "Western University / CSTAR (R. V. Patel; M. Khoshnam, I. Khalaji)",
   "group_short": "Western / CSTAR",
   "family": "academic",
   "category": "academic",
   "first_year": 2014,
   "latest_year": 2015,
   "versions": "2014 BioRob robotics-assisted catheter manipulation for ablation efficiency (title); 2015 IROS system with real-time force estimation (full); 3-DOF manipulator named as ongoing work (IROS 2015 Sec. V)",
   "target_anatomy": "cardiac ablation (atria)",
   "devices": [
    "catheter"
   ],
   "devices_driven": "one 7 Fr unidirectional steerable ablation catheter (Biosense Webster); handle cover removed, prismatic knob fixed to the stage slider (IROS 2015 Sec. II)",
   "n_dof": 1,
   "n_dof_detail": "1 actuated (pull-wire flexion); catheter body free in the sheath",
   "translation_mechanism": "other",
   "translation_detail": "other: body insertion not actuated; pull-wire driven by a Zaber T-LSR300B motorised linear stage",
   "rotation_mechanism": "none",
   "rotation_detail": "none (not actuated)",
   "device_range": "one catheter model",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "ATI Nano43 measures pull-wire tension; tip-tissue force estimated from tension plus tip pose (no tip sensor); ATI Nano17 under the tissue as ground truth (IROS 2015 Sec. II)",
   "haptics_leader": "none; GUI displays real-time contact-force estimate",
   "imaging_compat": "camera tracking of tip markers (640 x 480 px, 30 fps) as fluoroscopy stand-in",
   "sterility": "N.R.",
   "highest_validation": "bench",
   "validation_detail": "artificial tissue on a Nano17 sensor moved by a Zaber T-LSM050A stage, including 8.5 mm sinusoidal wall motion; three cases in Table II (IROS 2015 Sec. IV)",
   "key_numbers": "tip placed within +-1 mm of target; contact-force estimation error below 3 gf, maximum 2.64 gf (IROS 2015 abstract, Sec. V)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "render",
    "source": "khoshnam2015_ablation_IROS Fig. 1 (CAD of set-up), left part: motorized linear stage, handle clamp, pull-wire force sensor",
    "source_url": "https://doi.org/10.1109/iros.2015.7353821",
    "licence": "publisher copyright (IEEE)",
    "credit": "Khoshnam et al., 2015 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (2015), Fig. 1. publisher copyright (IEEE).",
    "edits": "native extract (3828x1769); cropped to the pull-wire drive; 3 leader arrows on white background erased (LaMa, imgprep erase --box/--line), robot untouched; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "cstar_ablation_khoshnam2014_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Proximal actuator: motorised stage pulling the catheter knob through a force sensor",
     "source_key": "khoshnam2015_robotics",
     "source": "Khoshnam et al., 2015 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (2015), Fig. 2, p. 2",
     "source_url": "https://doi.org/10.1109/iros.2015.7353821",
     "where": "Fig. 2, p. 2",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "cstar_ablation_khoshnam2014_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Catheter tip against a force sensor under a side camera, linear stage behind",
     "source_key": "khoshnam2015_robotics",
     "source": "Khoshnam et al., 2015 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (2015), Fig. 3, p. 2",
     "source_url": "https://doi.org/10.1109/iros.2015.7353821",
     "where": "Fig. 3, p. 2",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "cstar_ablation_khoshnam2014_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD of the 2014 set-up: handle actuation stage, camera and tip force sensor",
     "source_key": "khoshnam2014_robotics",
     "source": "Khoshnam et al., 5th IEEE RAS/EMBS International Conference on Biomedical Robotics and Biomechatronics (2014), Fig. 1, p. 2",
     "source_url": "https://doi.org/10.1109/biorob.2014.6913794",
     "where": "Fig. 1, p. 2",
     "licence": "publisher copyright (IEEE)"
    }
   ],
   "sources": [
    {
     "key": "khoshnam2015_robotics",
     "doi": "10.1109/iros.2015.7353821",
     "url": null,
     "title": "A robotics-assisted catheter manipulation system for cardiac ablation with real-time force estimation",
     "year": 2015,
     "venue": "2015 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS)"
    },
    {
     "key": "khoshnam2014_robotics",
     "doi": "10.1109/biorob.2014.6913794",
     "url": null,
     "title": "Robotics-assisted catheter manipulation for improving cardiac ablation efficiency",
     "year": 2014,
     "venue": "5th IEEE RAS/EMBS International Conference on Biomedical Robotics and Biomechatronics"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (IROS 2015); title (BioRob 2014)",
   "notes": "Boundary case: actuates only tip flexion of a conventional ablation catheter (compare robots_A3 toronto_nazari2024 EP-handle robot).",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "ryerson_cathnav_ganji2009",
   "name": "CathNav",
   "full_name": "CathNav / Althea I and Althea II: 3-DOF robots for semi-automatic and automatic navigation of steerable EP catheters",
   "group": "Ryerson University (now Toronto Metropolitan University; F. Janabi-Sharifi) with University of Waterloo (Y. Ganji) and St. Michael's Hospital (A. N. Cheema)",
   "group_short": "Ryerson",
   "family": "academic",
   "category": "academic",
   "first_year": 2009,
   "latest_year": 2021,
   "versions": "2009 IJCARS CathNav, called Althea I by the group (norouzighazbi2021 Sec. 1, ref. 14): Velmex linear stage + two rotary stages, stepper motors, 3 swine; 2021 Artif. Organs Althea II (norouzighazbi2021_design, full): three HerkuleX DRS-0602 smart servos for twist, translation and knob bending (Sec. 2.2.1-2.2.2) on an inclined 3D-printed arm (SLS nylon + FDM) riding a Macron MSA-R6S belt-driven linear actuator (325 mm travel, up to 6230 mm/s), customisable handle parts for other catheters, guidewires and sheaths, magnetic stainless-steel shaft holders, gearbox and external bearings removed, portable, assembly 20 min, five times faster than Althea I, two units can cooperate (Sec. 2.2, Figs. 2-3, 11); the 2024 grip-insert-release follower of the same group is robots_A3 toronto_nazari2024",
   "target_anatomy": "right atrium (intracardiac EP navigation)",
   "devices": [
    "guidewire",
    "catheter",
    "sheath"
   ],
   "devices_driven": "one bidirectional steerable ablation catheter SteeroCath-T (Boston Scientific): 7 Fr shaft, 8 Fr tip, 110 cm (ganji2009 Sec. System setup); Althea II: EP catheters with rotational knobs, swappable handle holder parts for other handles, guidewires and sheaths (norouzighazbi2021 Sec. 2.2.1)",
   "n_dof": 3,
   "n_dof_detail": "3 (insertion/retraction, handle twist, knob deflection)",
   "translation_mechanism": "linear-stage+clamp",
   "translation_detail": "linear-stage+clamp (2009: Velmex linear stage moves the handle, telescopic tubing keeps the external shaft straight; 2021: belt-driven linear actuator carries the handle holder, norouzighazbi2021 Sec. 2.2.2)",
   "rotation_mechanism": "handle-rotation",
   "rotation_detail": "two rotary stages: one twists the handle, one turns the steering knob",
   "device_range": "one catheter model",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "none",
   "haptics_leader": "Novint Falcon 3-D haptic device as input (force feedback N.R.); CathNav GUI",
   "imaging_compat": "NDI Aurora EM tracking, two sensors on the distal shaft; fluoroscopy",
   "sterility": "N.R.",
   "highest_validation": "animal",
   "validation_detail": "3 swine (St. Michael's Hospital vivarium); catheter introduced manually into the right atrium then mounted on the robot; automatic navigation to EM-sensor targets (high RA, tricuspid annulus) (ganji2009 Sec. Experiments setup, Results); Althea II 2021: bench accuracy/repeatability in positioning and velocity modes, comparison with Althea I, cooperative two-robot object manipulation, mitral-valve and clip grasping inside an artificial heart model, image-based visual servoing; no in vivo test (norouzighazbi2021 Sec. 3-4)",
   "key_numbers": "mean distance to target 6.53 mm, all trials below 10 mm (ganji2009 Abstract, Results); Althea II: > 90 % accuracy in velocity and positioning modes, about 2.5x more accurate and 6x more repeatable than Althea I (Table 5), cooperative object path error 0.299 mm, YOLO tip detection MSE 0.05 mm (Table 4), assembly 18 / 23 / 17 min by three people (norouzighazbi2021)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "photo",
    "source": "norouzighazbi2021_design Fig. 2(A), right photograph (Althea II prototype on its belt-driven linear actuator), p. E174, Artif. Organs 2021 doi:10.1111/aor.13870",
    "source_url": "https://doi.org/10.1111/aor.13870",
    "licence": "publisher copyright (Wiley / ICAOT)",
    "credit": "Norouzi‐Ghazbi et al., Artificial Organs (2021), Fig. 2. publisher copyright (Wiley / ICAOT).",
    "edits": "native extract (1890 x 1217 figure); cropped to the photograph inside panel (A); nothing erased; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "ryerson_cathnav_ganji2009_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Althea II motors and motions, inclined arm and rotatory handle holder, with photos",
     "source_key": "norouzighazbi2021_design",
     "source": "Norouzi‐Ghazbi et al., Artificial Organs (2021), Fig. 2(A)-(B), p. E174",
     "source_url": "https://doi.org/10.1111/aor.13870",
     "where": "Fig. 2(A)-(B), p. E174",
     "licence": "publisher copyright (Wiley / ICAOT)"
    },
    {
     "id": "ryerson_cathnav_ganji2009_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Two Althea II units cooperating, magnetic shaft holders and mated catheter tips",
     "source_key": "norouzighazbi2021_design",
     "source": "Norouzi‐Ghazbi et al., Artificial Organs (2021), Fig. 11(A)-(C), p. E182",
     "source_url": "https://doi.org/10.1111/aor.13870",
     "where": "Fig. 11(A)-(C), p. E182",
     "licence": "publisher copyright (Wiley / ICAOT)"
    },
    {
     "id": "ryerson_cathnav_ganji2009_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Magnetic shaft holders routing the catheter and the EM-compatible test table",
     "source_key": "norouzighazbi2021_design",
     "source": "Norouzi‐Ghazbi et al., Artificial Organs (2021), Fig. 3(A)-(B), p. E175",
     "source_url": "https://doi.org/10.1111/aor.13870",
     "where": "Fig. 3(A)-(B), p. E175",
     "licence": "publisher copyright (Wiley / ICAOT)"
    },
    {
     "id": "ryerson_cathnav_ganji2009_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Cooperative object manipulation by two catheters beside the EM field generator",
     "source_key": "norouzighazbi2021_design",
     "source": "Norouzi‐Ghazbi et al., Artificial Organs (2021), Fig. 13, p. E183",
     "source_url": "https://doi.org/10.1111/aor.13870",
     "where": "Fig. 13, p. E183",
     "licence": "publisher copyright (Wiley / ICAOT)"
    },
    {
     "id": "ryerson_cathnav_ganji2009_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Catheter grasping the mitral valve and clip inside an artificial heart model",
     "source_key": "norouzighazbi2021_design",
     "source": "Norouzi‐Ghazbi et al., Artificial Organs (2021), Fig. 12, p. E182",
     "source_url": "https://doi.org/10.1111/aor.13870",
     "where": "Fig. 12, p. E182",
     "licence": "publisher copyright (Wiley / ICAOT)"
    },
    {
     "id": "ryerson_cathnav_ganji2009_06",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Althea II system overview: smart motors, PC, EM tracking, camera and shaft holders",
     "source_key": "norouzighazbi2021_design",
     "source": "Norouzi‐Ghazbi et al., Artificial Organs (2021), Fig. 1, p. E173",
     "source_url": "https://doi.org/10.1111/aor.13870",
     "where": "Fig. 1, p. E173",
     "licence": "publisher copyright (Wiley / ICAOT)"
    }
   ],
   "sources": [
    {
     "key": "ganji2009_robot",
     "doi": "10.1007/s11548-009-0296-z",
     "url": null,
     "title": "Robot-assisted catheter manipulation for intracardiac navigation",
     "year": 2009,
     "venue": "International Journal of Computer Assisted Radiology and Surgery"
    },
    {
     "key": "norouzighazbi2021_design",
     "doi": "10.1111/aor.13870",
     "url": null,
     "title": "Design and experimental evaluation of an automated catheter operating system",
     "year": 2021,
     "venue": "Artificial Organs"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (IJCARS 2009; Althea II, norouzighazbi2021_design, )",
   "notes": "Earlier, distinct robot of the A3 Toronto lineage. For A3's 'Althea II year N.R.': Althea II is Norouzi-Ghazbi et al. 2021 (Artif. Organs): reduced weight, assembly 20 min (5x faster), tip detection accuracy 0.05 mm, target accuracy above 90% in velocity and positioning modes (abstract). | 2026-11-08 X3: Althea II paper read in full; it names the 2009 CathNav robot Althea I (ref. 14), so Althea I and II are versions of this row and toronto_nazari2024 is the third generation (its 'Althea II, year N.R.' = 2021). Main picture now Althea II (2021); old 272 px 2009 thumbnail kept as ryerson_cathnav_ganji2009_prev.png",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "cathpilot_zhou2022",
   "name": "CathPilot",
   "full_name": "CathPilot (expandable cable-driven tip platform steered through a 3-D cam handle)",
   "group": "Toronto Metropolitan University (M. A. Tavallaei) with Sunnybrook Research Institute (G. A. Wright), University of Toronto (A. Dueck), Magellan Biomedical, University of Waterloo",
   "group_short": "Toronto Metropolitan",
   "family": "tip",
   "category": "actuated-device",
   "first_year": 2022,
   "latest_year": 2023,
   "versions": "2022 TMECH design and bench verification; 2023 TBME performance validation, ex-vivo CTO crossing and in-vivo porcine safety",
   "target_anatomy": "peripheral arteries, chronic total occlusion (CTO) crossing",
   "devices": [
    "guidewire",
    "catheter",
    "sheath"
   ],
   "devices_driven": "CathPilot catheter positions a standard guidewire tip; frame deliverable through a 12 Fr sheath (OD 5.3 mm), expanding to 20 mm (TMECH 2022 Sec. III)",
   "n_dof": 2,
   "n_dof_detail": "2 (planar positioning of the guidewire end-effector within the expanded frame)",
   "translation_mechanism": "tendon/tip-actuation",
   "translation_detail": "tendon/tip-actuation (four PTFE cables, 0.012 in, from handle to an end-effector suspended in an expandable frame)",
   "rotation_mechanism": "not-reported",
   "rotation_detail": "N.R. (planar 2-DOF)",
   "device_range": "standard guidewire through the end-effector; several frame opening diameters tested",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "none (passive)",
   "haptics_leader": "handle with a 2-DOF 3-D cam surface sets all four cable lengths: fully manual mechanical teleoperation, no motors (TMECH 2022 Sec. III)",
   "imaging_compat": "X-ray fluoroscopy (N.R. further)",
   "sterility": "N.R.",
   "highest_validation": "animal",
   "validation_detail": "TBME 2023: tortuous vessel phantom (target reach vs non-steerable and steerable catheters), ex-vivo human CTO samples (fresh and fixed), in-vivo porcine aorta in one male pig of 56.6 kg",
   "key_numbers": "target-reach success 31% non-steerable, 69% steerable, 100% CathPilot; CTO crossing 83% fresh and 100% fixed; up to four times higher force delivery and pushability (TBME 2023 abstract); submillimetre positioning (TMECH 2022 abstract)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "render",
    "source": "zhou2022_cathpilot_TMECH Fig. 1 (CAD of manipulator unit, multilumen catheter, user-input handle)",
    "source_url": "https://doi.org/10.1109/tmech.2022.3188955",
    "licence": "CC BY-NC-ND 4.0 (article licence line); zhou2023_cathpilot_TBME is CC BY 4.0",
    "credit": "Zhou et al., IEEE/ASME Transactions on Mechatronics (2022), Fig. 1. CC BY-NC-ND 4.0 (article licence line); zhou2023_cathpilot_TBME is CC BY 4.0.",
    "edits": "native extract (2000x595); text labels (OCR) and 3 blue arrows on white background erased (LaMa); faint grey residue in the erased label areas set to white; top 95 px cropped; 40 px white padding (render background); not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "cathpilot_zhou2022_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "Handle prototype with thumbstick and tensioner lock on a 12 Fr sheath",
     "source_key": "zhou2022_cathpilot",
     "source": "Zhou et al., IEEE/ASME Transactions on Mechatronics (2022), Fig. 7, p. 6",
     "source_url": "https://doi.org/10.1109/tmech.2022.3188955",
     "where": "Fig. 7, p. 6",
     "licence": "publisher copyright"
    },
    {
     "id": "cathpilot_zhou2022_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "CathPilot with silicone tube and lesion fixture in the catheterization lab",
     "source_key": "zhou2023_cathpilot",
     "source": "Zhou et al., IEEE Transactions on Biomedical Engineering (2023), Fig. 2, p. 3",
     "source_url": "https://doi.org/10.1109/tbme.2023.3276199",
     "where": "Fig. 2, p. 3",
     "licence": "publisher copyright"
    },
    {
     "id": "cathpilot_zhou2022_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Expandable cable-driven frame emerging from the delivery sheath, four stages",
     "source_key": "zhou2022_cathpilot",
     "source": "Zhou et al., IEEE/ASME Transactions on Mechatronics (2022), Fig. 3, p. 3",
     "source_url": "https://doi.org/10.1109/tmech.2022.3188955",
     "where": "Fig. 3, p. 3",
     "licence": "publisher copyright"
    },
    {
     "id": "cathpilot_zhou2022_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD of the handle unit: shell, cam surface, sensor module, tensioner",
     "source_key": "zhou2022_cathpilot",
     "source": "Zhou et al., IEEE/ASME Transactions on Mechatronics (2022), Fig. 4, p. 4",
     "source_url": "https://doi.org/10.1109/tmech.2022.3188955",
     "where": "Fig. 4, p. 4",
     "licence": "publisher copyright"
    },
    {
     "id": "cathpilot_zhou2022_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Spring-loaded tensioner pulleys and brake surfaces inside the handle, top view",
     "source_key": "zhou2022_cathpilot",
     "source": "Zhou et al., IEEE/ASME Transactions on Mechatronics (2022), Fig. 6, p. 6",
     "source_url": "https://doi.org/10.1109/tmech.2022.3188955",
     "where": "Fig. 6, p. 6",
     "licence": "publisher copyright"
    },
    {
     "id": "cathpilot_zhou2022_06",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Force test layout: CathPilot, phantom, load cell and GUI",
     "source_key": "zhou2023_cathpilot",
     "source": "Zhou et al., IEEE Transactions on Biomedical Engineering (2023), Fig. 5, p. 5",
     "source_url": "https://doi.org/10.1109/tbme.2023.3276199",
     "where": "Fig. 5, p. 5",
     "licence": "publisher copyright"
    },
    {
     "id": "cathpilot_zhou2022_07",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Occlusion-crossing phantom setup with camera, GUI and delivery sheath",
     "source_key": "zhou2022_cathpilot",
     "source": "Zhou et al., IEEE/ASME Transactions on Mechatronics (2022), Fig. 10, p. 8",
     "source_url": "https://doi.org/10.1109/tmech.2022.3188955",
     "where": "Fig. 10, p. 8",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "zhou2022_cathpilot",
     "doi": "10.1109/tmech.2022.3188955",
     "url": null,
     "title": "The CathPilot: A Novel Approach for Accurate Interventional Device Steering and Tracking",
     "year": 2022,
     "venue": "IEEE/ASME Transactions on Mechatronics"
    },
    {
     "key": "zhou2023_cathpilot",
     "doi": "10.1109/tbme.2023.3276199",
     "url": null,
     "title": "The CathPilot: Performance Validation and Preclinical Safety and Feasibility Assessment",
     "year": 2023,
     "venue": "IEEE Transactions on Biomedical Engineering"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (TMECH 2022, TBME 2023)",
   "notes": "Not motorised: the 'teleoperation' is a cable-and-cam transmission; included as a boundary case because the coordinator's snowball list names it. Tavallaei is the author of the Western University RCNS papers (western_thakur2009).",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "cathrob_cercenelli2017",
   "name": "CathROB",
   "full_name": "CathROB remote catheter navigation system (with its 2007-2008 telerobotic predecessor)",
   "group": "University of Bologna, Laboratory of Bioengineering (L. Cercenelli, E. Marcelli, G. Plicchi, B. Bortolani), developed with Tre Esse Progettazione Biomedica",
   "group_short": "U. Bologna",
   "family": "academic",
   "category": "academic",
   "first_year": 2007,
   "latest_year": 2017,
   "versions": "2007 ASAIO J telerobotic system (cercenelli2007_initial, full): driving unit on an articulation arm giving advance/withdrawal, rotation and tip steering to a standard EP catheter, PIC16F876 control unit at the bedside, remote push-button box with display (wired or wireless), automatic repositioning to stored targets (Methods, Figs. 1-2); 2008 Computers in Cardiology telerobotic system with force sensing (title); 2017 CathROB: mock handle plus push-button box, compact arm-mounted Motion Unit (full)",
   "target_anatomy": "cardiac electrophysiology mapping and RF ablation (right atrium in sheep; silicone left-atrium model)",
   "devices": [
    "catheter"
   ],
   "devices_driven": "one standard tip-steerable EP catheter; adapters for Navistar Thermocool and EZ-steer bidirectional (Biosense Webster), Sprinklr XL 7 Fr (Medtronic), Blazer II XP (Boston Scientific); tested with Navistar Thermocool 4 mm 7.5 Fr (Sec. 2.1); 2007: RF Enhancr steerable EP catheter (Medtronic) (cercenelli2007 Methods)",
   "n_dof": 3,
   "n_dof_detail": "3 (advance/withdraw, rotation, tip bend/straighten)",
   "translation_mechanism": "linear-stage+clamp",
   "translation_detail": "linear-stage+clamp (Motion Unit moves the handle held by a spring-preloaded jaw block with silicone-coated rollers; Delrin telescopic sheath to the introducer)",
   "rotation_mechanism": "handle-rotation",
   "rotation_detail": "DC micromotor rotates the gripped handle; steering element turned through catheter-specific adapters",
   "device_range": "four commercial EP catheter models via adapters",
   "footprint_mm": "Motion Unit 53 x 8 x 11 cm (Fig. 4 labels; text prints 53 x 8 x 110 cm) retracted, 73 x 8 x 11 cm extended (Sec. 2.1)",
   "mass_kg": "2.3 (Motion Unit); supporting arm 7.5 (Sec. 2.1, Fig. 4)",
   "force_sensing": "Honeywell FS-series piezoresistive sensor in the push path; alarm at 60% and stop at 80% of a perforation force of 128 +- 12 gF measured on excised ovine atrium (Sec. 2.1)",
   "haptics_leader": "mock catheter handle plus push-button box; vibration motor and acoustic alarm when thresholds are exceeded; up to four stored targets for automatic repositioning",
   "imaging_compat": "standard fluoroscopy and CARTO electroanatomic mapping; operator outside the radiation field",
   "sterility": "disposable or sterilisable adapters; Motion Unit and arm draped in sterile polyethylene in vivo",
   "highest_validation": "animal",
   "validation_detail": "in vitro silicone heart and vascular mock-up; in vivo 4 sheep (49 +- 4 kg) with right-atrial CARTO mapping and RF ablation at RA isthmus and posterior wall (Sec. 2.2, 3); 2007 predecessor: 3 sheep (58 +- 3 kg), navigation and repositioning to 12 predefined endocardial targets under fluoroscopy, manual vs robotic (cercenelli2007 Methods, Results)",
   "key_numbers": "automatic repositioning error 1.5 +- 0.6 mm (left targets) and 1.7 +- 0.5 mm (right; abstract 1.7 +- 0.4); map-to-CT deviation 1.37 +- 0.98 mm; in vivo set-up 5 +- 3 min, maps 63 +- 8 points in 36 +- 7 min with 15 +- 3 min fluoroscopy; speeds 13-18 mm/s, 30-45 deg/s, 2-4 mm/s; no perforation or rhythm change (Sec. 2.1, 3); 2007: navigation 13.0 +- 5.6 s robotic vs 16.1 +- 6.4 s manual, repositioning 9.2 +- 2.5 vs 17.8 +- 7.1 s (both p < 0.001); bench repositioning accuracy 0.2 +- 0.1 mm, 1.4 +- 0.8 mm, 2.1 +- 0.9 mm (longitudinal, rotational, steering) (cercenelli2007 Abstract, Methods)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "cleared",
    "grade": "B",
    "kind": "photo",
    "source": "cercenelli2017_cathrob Fig. 2(b) top (Motion Unit on articulated arm), native embedded image on PDF p. 3 from the PMC open-access PDF",
    "source_url": "https://doi.org/10.1155/2017/2712453",
    "licence": "CC BY 4.0",
    "credit": "Cercenelli et al., Applied Bionics and Biomechanics (2017), Fig. 2(b). CC BY 4.0.",
    "edits": "native extract (1586 x 1320); cropped to Motion Unit and upper arm; no erasing (labels were vector overlays outside the bitmap); not upscaled (upscale disabled)",
    "file": "pictures/cathrob_cercenelli2017.jpg"
   },
   "pictures": [
    {
     "id": "cathrob_cercenelli2017_01",
     "status": "cleared",
     "file": "pictures/extra/cathrob_cercenelli2017_01.jpg",
     "thumb": "pictures/thumbs/cathrob_cercenelli2017_01.jpg",
     "kind": "in-use",
     "caption": "Draped Motion Unit on its arm prepared for the in-vivo animal study",
     "source_key": "cercenelli2017_cathrob",
     "source": "Cercenelli et al., Applied Bionics and Biomechanics (2017), Fig. 9, p. 9",
     "source_url": "https://doi.org/10.1155/2017/2712453",
     "where": "Fig. 9, p. 9",
     "licence": "CC BY 4.0 (Hindawi; PDF states 'Creative Commons Attribution License')"
    },
    {
     "id": "cathrob_cercenelli2017_02",
     "status": "cleared",
     "file": "pictures/extra/cathrob_cercenelli2017_02.jpg",
     "thumb": "pictures/thumbs/cathrob_cercenelli2017_02.jpg",
     "kind": "in-use",
     "caption": "In-vitro set-up: arm-mounted Motion Unit feeding a catheter into a vascular model",
     "source_key": "cercenelli2017_cathrob",
     "source": "Cercenelli et al., Applied Bionics and Biomechanics (2017), Fig. 8(a), p. 8",
     "source_url": "https://doi.org/10.1155/2017/2712453",
     "where": "Fig. 8(a), p. 8",
     "licence": "CC BY 4.0 (Hindawi; PDF states 'Creative Commons Attribution License')"
    },
    {
     "id": "cathrob_cercenelli2017_03",
     "status": "cleared",
     "file": "pictures/extra/cathrob_cercenelli2017_03.jpg",
     "thumb": "pictures/thumbs/cathrob_cercenelli2017_03.jpg",
     "kind": "setup",
     "caption": "Whole system: arm-mounted Motion Unit, GUI monitor, control box and push-button box",
     "source_key": "cercenelli2017_cathrob",
     "source": "Cercenelli et al., Applied Bionics and Biomechanics (2017), Fig. 2(b), p. 3",
     "source_url": "https://doi.org/10.1155/2017/2712453",
     "where": "Fig. 2(b), p. 3",
     "licence": "CC BY 4.0 (Hindawi; PDF states 'Creative Commons Attribution License')"
    },
    {
     "id": "cathrob_cercenelli2017_04",
     "status": "cleared",
     "file": "pictures/extra/cathrob_cercenelli2017_04.jpg",
     "thumb": "pictures/thumbs/cathrob_cercenelli2017_04.jpg",
     "kind": "close-up",
     "caption": "Motion Unit holding an EP catheter handle, with clamp insets",
     "source_key": "cercenelli2017_cathrob",
     "source": "Cercenelli et al., Applied Bionics and Biomechanics (2017), Fig. 3, p. 4",
     "source_url": "https://doi.org/10.1155/2017/2712453",
     "where": "Fig. 3, p. 4",
     "licence": "CC BY 4.0 (Hindawi; PDF states 'Creative Commons Attribution License')"
    },
    {
     "id": "cathrob_cercenelli2017_05",
     "status": "cleared",
     "file": "pictures/extra/cathrob_cercenelli2017_05.jpg",
     "thumb": "pictures/thumbs/cathrob_cercenelli2017_05.jpg",
     "kind": "photo",
     "caption": "Disassembled Motion Unit, supporting arm, anchoring plate and cable",
     "source_key": "cercenelli2017_cathrob",
     "source": "Cercenelli et al., Applied Bionics and Biomechanics (2017), Fig. 4, p. 4",
     "source_url": "https://doi.org/10.1155/2017/2712453",
     "where": "Fig. 4, p. 4",
     "licence": "CC BY 4.0 (Hindawi; PDF states 'Creative Commons Attribution License')"
    },
    {
     "id": "cathrob_cercenelli2017_06",
     "status": "cleared",
     "file": "pictures/extra/cathrob_cercenelli2017_06.jpg",
     "thumb": "pictures/thumbs/cathrob_cercenelli2017_06.jpg",
     "kind": "close-up",
     "caption": "Handle adapters fitting four commercial tip-steerable EP catheters",
     "source_key": "cercenelli2017_cathrob",
     "source": "Cercenelli et al., Applied Bionics and Biomechanics (2017), Fig. 5, p. 5",
     "source_url": "https://doi.org/10.1155/2017/2712453",
     "where": "Fig. 5, p. 5",
     "licence": "CC BY 4.0 (Hindawi; PDF states 'Creative Commons Attribution License')"
    },
    {
     "id": "cathrob_cercenelli2017_07",
     "status": "cleared",
     "file": "pictures/extra/cathrob_cercenelli2017_07.jpg",
     "thumb": "pictures/thumbs/cathrob_cercenelli2017_07.jpg",
     "kind": "leader",
     "caption": "Command interface: mock catheter handle and push-button box",
     "source_key": "cercenelli2017_cathrob",
     "source": "Cercenelli et al., Applied Bionics and Biomechanics (2017), Fig. 6, p. 6",
     "source_url": "https://doi.org/10.1155/2017/2712453",
     "where": "Fig. 6, p. 6",
     "licence": "CC BY 4.0 (Hindawi; PDF states 'Creative Commons Attribution License')"
    },
    {
     "id": "cathrob_cercenelli2017_08",
     "status": "cleared",
     "file": "pictures/extra/cathrob_cercenelli2017_08.jpg",
     "thumb": "pictures/thumbs/cathrob_cercenelli2017_08.jpg",
     "kind": "render",
     "caption": "3D rendering of the system attached to a cath-lab table by an articulated arm",
     "source_key": "cercenelli2017_cathrob",
     "source": "Cercenelli et al., Applied Bionics and Biomechanics (2017), Fig. 1, p. 2",
     "source_url": "https://doi.org/10.1155/2017/2712453",
     "where": "Fig. 1, p. 2",
     "licence": "CC BY 4.0 (Hindawi; PDF states 'Creative Commons Attribution License')"
    }
   ],
   "sources": [
    {
     "key": "cercenelli2017_cathrob",
     "doi": "10.1155/2017/2712453",
     "url": null,
     "title": "CathROB: A Highly Compact and Versatile Remote Catheter Navigation System",
     "year": 2017,
     "venue": "Applied Bionics and Biomechanics"
    },
    {
     "key": "cercenelli2007_initial",
     "doi": "10.1097/mat.0b013e3181484cd0",
     "url": null,
     "title": "Initial Experience With a Telerobotic System to Remotely Navigate and Automatically Reposition Standard Steerable EP Catheters",
     "year": 2007,
     "venue": "ASAIO Journal"
    },
    {
     "key": "marcelli2008_novel",
     "doi": "10.1109/cic.2008.4748996",
     "url": null,
     "title": "A novel telerobotic system to remotely navigate standard electrophysiology catheters",
     "year": 2008,
     "venue": "2008 Computers in Cardiology"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (CathROB 2017; 2007 ASAIO, ); title (2008)",
   "notes": "Venue is Applied Bionics and Biomechanics (Hindawi, CC BY 4.0). Only CathROB is listed by li2024_design as an academic reference system next to commercial ones. | 2026-11-08 X3: 2007 paper read in full. Its two photographs (Fig. 2 driving unit on the articulation arm; Fig. 3 in vivo sheep set-up with the operator at the push-button box, 975 px greyscale) are not added because the gallery already holds 8 pictures; they are candidates if the coordinator swaps one",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "harvard_mccath_kesner2011",
   "name": "Motion-comp. catheter",
   "full_name": "Harvard motion-compensation catheter system (voice-coil guidewire drive with 3-D ultrasound servoing)",
   "group": "Harvard SEAS BioRobotics Lab (R. D. Howe; S. B. Kesner)",
   "group_short": "Harvard",
   "family": "academic",
   "category": "academic",
   "first_year": 2011,
   "latest_year": 2014,
   "versions": "2011 ICRA force control of flexible catheter robots for beating-heart surgery (title); 2011 TRO position control with friction and backlash compensation (full, PMC author manuscript); 2014 IJRR robotic catheter cardiac ablation combining 3DUS guidance and force control, new force-sensing RF ablation end effector (full, kesner2014_robotic)",
   "target_anatomy": "intracardiac beating-heart repair (mitral annulus tracking); RF cardiac ablation (kesner2014 Sec. 1-2)",
   "devices": [
    "guidewire",
    "sheath"
   ],
   "devices_driven": "guidewire/instrument sliding in a fixed 85 cm Teflon sheath with steel spring; in vivo 1.5 mm OD guidewire in 1.6 mm ID sheath (TRO 2011 Sec. III, Table I)",
   "n_dof": 1,
   "n_dof_detail": "1 actuated (fast axial translation); bending and rotation by the clinician with conventional catheter controls",
   "translation_mechanism": "other",
   "translation_detail": "other: voice-coil linear actuator (H2W NCC20-18-02-1X, 50.8 mm travel, 26.7 N peak) on a BX3-3 linear ball slide",
   "rotation_mechanism": "none",
   "rotation_detail": "none (manual); pull-wire bending and guidewire twisting proposed as future DOF (Fig. 18)",
   "device_range": "sheath ID 1.59-2.38 mm with guidewire OD 0.76-2.23 mm tested (Table I)",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "LCFD-1KG load cell (10 N range) in the drive measures friction; LP-50F potentiometer for position (TRO 2011); IJRR 2014: catheter-tip force sensor, a reflective surface on perpendicular 0.25 mm NiTi flexures read by a fibre-optic transducer, 3D-printed (Objet Connex500), about 5 mm diameter, integrated with the RF ablation electrode, calibrated against an ATI Mini40 (Sec. 2.2, Figs. 4-5)",
   "haptics_leader": "linear joystick adds commands to the fast axis; no force feedback reported",
   "imaging_compat": "3-D ultrasound (Philips SONOS 7500, epicardial) with GPU Radon-transform tool tracking; EKF compensates 50-100 ms imaging delay",
   "sterility": "N.R.",
   "highest_validation": "animal",
   "validation_detail": "one 75 kg pig, catheter inserted through the top of the left atrium (not through the vasculature), mitral-annulus tracking trials longer than 15 s; number of trials N.R. (TRO 2011 Sec. VII); IJRR 2014: bench force-control runs and water-tank runs under 3DUS against a target moving 12 mm at about 1 Hz (sinusoid and human mitral-annulus trajectory), robotic vs manual Medtronic RF Marinr MCXL catheter (Sec. 4-5, Figs. 16-17)",
   "key_numbers": "in vivo RMS tracking error below 1.0 mm in all trials (0.77 mm shown) vs above 8 mm without compensation; friction compensation up to 2 N; bench MAE 1.28 -> 0.26 mm (inverse compensation, 1 Hz) and 2.34 -> 0.24 mm (model-based); design targets >= 20 mm travel, >= 210 mm/s, >= 3800 mm/s^2, about 4 N (TRO 2011); IJRR 2014: 1 N contact force held on the moving target under 3DUS with 0.08 N RMS error, 97 % less RMS contact-resistance variation than the manual catheter, force control improved motion tracking by about 20 % (Abstract)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "render",
    "source": "kesner2011_force Fig. 2 (drive system CAD, p. 2), IEEE ICRA 2011,",
    "source_url": "https://doi.org/10.1109/icra.2011.5979690",
    "licence": "publisher copyright (IEEE)",
    "credit": "Kesner et al., 2011 IEEE International Conference on Robotics and Automation (2011), Fig. 2. publisher copyright (IEEE).",
    "edits": "native extract (embedded 1179 x 526); no crop; nothing erased; none upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "harvard_mccath_kesner2011_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "3D-printed optical force sensor at the tip of the catheter guidewire stem",
     "source_key": "kesner2011_force",
     "source": "Kesner et al., 2011 IEEE International Conference on Robotics and Automation (2011), Fig. 4 (photograph), p. 2",
     "source_url": "https://doi.org/10.1109/icra.2011.5979690",
     "where": "Fig. 4 (photograph), p. 2",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "harvard_mccath_kesner2011_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Force-sensing RF ablation end effector: solid model and 3D-printed prototype on the guidewire",
     "source_key": "kesner2014_robotic",
     "source": "Kesner et al., The International Journal of Robotics Research (2014), Fig. 4(a), p. 633",
     "source_url": "https://doi.org/10.1177/0278364913511350",
     "where": "Fig. 4(a), p. 633",
     "licence": "publisher copyright"
    },
    {
     "id": "harvard_mccath_kesner2011_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Robotic catheter tip on a moving target in the water tank beside the 3DUS probe",
     "source_key": "kesner2014_robotic",
     "source": "Kesner et al., The International Journal of Robotics Research (2014), Fig. 17 (bottom), p. 641",
     "source_url": "https://doi.org/10.1177/0278364913511350",
     "where": "Fig. 17 (bottom), p. 641",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "kesner2011_position",
     "doi": "10.1109/tro.2011.2160467",
     "url": null,
     "title": "Position Control of Motion Compensation Cardiac Catheters",
     "year": 2011,
     "venue": "IEEE Transactions on Robotics"
    },
    {
     "key": "kesner2011_force",
     "doi": "10.1109/icra.2011.5979690",
     "url": null,
     "title": "Force control of flexible catheter robots for beating heart surgery",
     "year": 2011,
     "venue": "2011 IEEE International Conference on Robotics and Automation"
    },
    {
     "key": "kesner2014_robotic",
     "doi": "10.1177/0278364913511350",
     "url": null,
     "title": "Robotic catheter cardiac ablation combining ultrasound guidance and force control",
     "year": 2014,
     "venue": "The International Journal of Robotics Research"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (TRO 2011 via PMC HTML; IJRR 2014, ); title (ICRA 2011)",
   "notes": "Proximal drive for one fast DOF; same Harvard group later built the ICE-steering robot (harvard_ice_loschak2017). Boundary case: transatrial, not transvascular. | 2026-11-08 X3: IJRR 2014 read in full: same drive (voice coil NCC20-18-02-1X on a BX3-3 slide, LP-50F), 85 cm Teflon or Nylon sheath with steel-spring guidewire (Sec. 2); no new animal test (validation stays animal from TRO 2011)",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "harvard_ice_loschak2017",
   "name": "ICE catheter robot",
   "full_name": "Harvard 4-DOF robotic ultrasound (ICE) catheter steering system",
   "group": "Harvard SEAS (R. D. Howe; P. M. Loschak, A. Degirmenci) with MIT Lincoln Laboratory (L. J. Brattain) and Beth Israel Deaconess Medical Center (C. M. Tschabrunn, E. Anter)",
   "group_short": "Harvard",
   "family": "academic",
   "category": "academic",
   "first_year": 2017,
   "latest_year": 2020,
   "versions": "2017 TRO algorithms for automatically pointing ICE catheters, benchtop (full, PMC author manuscript); 2020 IJRR in-vivo automatic steering with respiratory motion compensation (full, loschak2020_automatically); earlier in vivo navigation study Degirmenci et al. 2016 (cited in loschak2020 Sec. 1, not read)",
   "target_anatomy": "intracardiac echocardiography in the heart chambers",
   "devices": [
    "catheter"
   ],
   "devices_driven": "AcuNav 10 Fr (3.30 mm) 110 cm ICE catheter with 64-element array (Biosense Webster) (TRO 2017 Sec. II)",
   "n_dof": 4,
   "n_dof_detail": "4 (pitch knob, yaw knob, handle roll, handle translation)",
   "translation_mechanism": "linear-stage+clamp",
   "translation_detail": "linear-stage+clamp (lead-screw translation stage carries the whole handle)",
   "rotation_mechanism": "handle-rotation",
   "rotation_detail": "motor grounded to the stage turns the handle by timing belt; two handle-mounted motors turn the knobs by timing belts",
   "device_range": "one ICE catheter model",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "none reported",
   "haptics_leader": "none (automatic target-based steering)",
   "imaging_compat": "ICE ultrasound; EM tracking of instrument tip in tests; IJRR 2020: four EM trackers (two on the US catheter, one on the target catheter, one on the chest wall for respiration) (Sec. 3.2)",
   "sterility": "N.R.",
   "highest_validation": "animal",
   "validation_detail": "2017: benchtop water tank with gelatin left-atrium phantom; 2020: one 64 kg live pig, US catheter via a 14 Fr femoral-vein introducer into the right atrium, target 6 Fr quadpolar catheter in the left ventricle, heart paced at 120 bpm; volume-imaging steps (18 steps, 133 s), instrument tracking (329 s) and tracking a manually steered target (431 s) (IJRR 2020 Sec. 3.2-3.3)",
   "key_numbers": "benchtop position RMS 1.9 mm; imager spinning 0.25 deg RMS with 1.0 mm tip drift; 3-D pointing 1.6 mm and 0.17 deg RMS; test speeds <= 1 mm/s and <= 0.5 deg/s; 6.5 W brushed DC motors with Maxon EPOS2 (TRO 2017); in vivo 1.05 mm and 1.33 deg mean absolute error with respiratory compensation (IJRR 2020 abstract); in vivo step imaging 2.56 mm / 0.98 deg MAE over 134 s of well-modelled breathing, 6.59 mm / 2.27 deg when the model was outdated; manual-target tracking 2.81 deg MAE and 2.14 mm position MAE over 431 s (Sec. 3.3)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "photo",
    "source": "loschak2017_algorithms Fig. 11 (US catheter steering robot with 4 DOF); https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5311/5295822/ec2024e38a33/nihms820364f11.jpg (PMC5295822)",
    "source_url": "https://doi.org/10.1109/tro.2016.2623331",
    "licence": "publisher copyright (IEEE; NIH author manuscript in PMC)",
    "credit": "Loschak et al., IEEE Transactions on Robotics (2017), Fig. 11. publisher copyright (IEEE; NIH author manuscript in PMC).",
    "edits": "PMC figure image as is; not upscaled; labels and green dashed outline left in place (they cross the robot)",
    "file": null
   },
   "pictures": [
    {
     "id": "harvard_ice_loschak2017_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD of the catheter steering robot holding the ICE handle, beside a heart diagram",
     "source_key": "loschak2013_automated",
     "source": "loschak2013_automated, Fig. 1, p. 1 (ICRA 2013, 10.1109/icra.2013.6631410)",
     "source_url": null,
     "where": "Fig. 1, p. 1 (ICRA 2013, 10.1109/icra.2013.6631410)",
     "licence": "publisher copyright (IEEE)"
    }
   ],
   "sources": [
    {
     "key": "loschak2017_algorithms",
     "doi": "10.1109/tro.2016.2623331",
     "url": null,
     "title": "Algorithms for Automatically Pointing Ultrasound Imaging Catheters",
     "year": 2017,
     "venue": "IEEE Transactions on Robotics"
    },
    {
     "key": "loschak2020_automatically",
     "doi": "10.1177/0278364920903785",
     "url": null,
     "title": "Automatically steering cardiac catheters in vivo with respiratory motion compensation",
     "year": 2020,
     "venue": "The International Journal of Robotics Research"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (TRO 2017 via PMC HTML; IJRR 2020, )",
   "notes": "Second ICE-handle robot next to the Siemens one (siemens_ice_kim2020), which cites it as prior work. | 2026-11-08 X3: IJRR 2020 read in full; it has no photograph of the robot (only a small drawing in Fig. 3), so the main picture stays the TRO 2017 Fig. 11; one 64 kg pig confirms the animal level",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "buffalo_seta_srimathveeravalli2010",
   "name": "SETA",
   "full_name": "SETA (System for Endovascular Teleoperated Access)",
   "group": "State University of New York (SUNY) at Buffalo, Dept. of Mechanical and Aerospace Engineering (G. Srimathveeravalli, T. Kesavadas, X. Li)",
   "group_short": "U. Buffalo",
   "family": "academic",
   "category": "academic",
   "first_year": 2010,
   "latest_year": 2010,
   "versions": "2010 IJMRCAS (full); the same PI's later SAER robot (UIUC/Buffalo) is robots_A3 saer_sankaran2018; Ashammagari et al. 2016 IMECE automated aortic-arch access on the VIST simulator used a 7-DOF Robai Cyton arm, neither SETA nor SAER (ashammagari2016_image, full)",
   "target_anatomy": "neurovascular / endovascular access (design data from femoral-to-internal-carotid angiograms in rabbits and on VIST; srimathveeravalli2010_design Materials and Methods)",
   "devices": [
    "guidewire",
    "catheter"
   ],
   "devices_driven": "guidewire and catheter simultaneously, any standard device 0.014-0.13 in (friction-wheel range); bench: 0.035 in guidewire + 5 Fr Boston Scientific Expo catheter (Results); VIST trial: the manual angiogram (0.035 / 0.014 in Emerald guidewires, 5 Fr Tempo Aqua catheter) repeated with SETA",
   "n_dof": 3,
   "n_dof_detail": "3 motorised: guidewire insert/withdraw, catheter insert/withdraw, catheter twist (three Maxon EC-22 motors); a travelling cart carrying the guidewire drive and the steering stage runs on a pulley (Design of patient-side slave, Actuators; Fig. 2)",
   "translation_mechanism": "friction-roller",
   "translation_detail": "friction-roller: driven lower + idler upper 2 in polyurethane wheels (Shore 55A, mu ~0.6), spring-tensioned self-adjusting housing, normal load 1.275 N (Slave actuators; Fig. 3)",
   "rotation_mechanism": "rotating-clamp",
   "rotation_detail": "catheter only: miniature gripper of brass roller pins on O-ring-tensioned steel shafts (transmits torque, allows axial slip) turned by a pulley from a servomotor and torque sensor (Slave actuators; Fig. 4)",
   "device_range": "0.014-0.13 in (Slave actuators)",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "proximal: LXT 971 torque sensor (Cooper Instruments, +/-2.5 Nm, 0.005 Nm resolution) between each motor and its wheel/pulley, converted to axial and radial tool forces (Slave actuators; Teleoperation)",
   "haptics_leader": "Novint Falcon; twist mapped to left-right stylus motion; force-reflecting loop at 500 Hz with Butterworth tremor filter (5-25 Hz), motion scaling and delay term (Teleoperation and haptic feedback, Eq. 1, Fig. 5)",
   "imaging_compat": "N.R.",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "bench: step inputs to 30/60/90 mm at 1000/2500/5000 rpm, 15 repeats each, plus ramps (Fig. 6); steering 1 deg steps over 360 deg, 10 cycles each way on a 5 F catheter (Fig. 7); phantom: teleoperated 0.035 in guidewire in a silicone vessel with one bifurcation (Fig. 8); VIST simulator: 8 neurovascular surgeons and fellows (7 M, 1 F, mean 500 cases) repeated a carotid angiogram, procedure time 87.42 s robotic vs 80.57 s manual (p = 0.829), contrast 7 vs 5.75 cc (p = 0.723), 1 participant did not finish; questionnaire 2.25-3.0 of 4 (Table 3, Fig. 11). In vivo animal studies only planned (Abstract, Conclusion)",
   "key_numbers": "insertion slip < 0.4 mm per 100 mm; teleoperated phantom lag < 0.003 in; back-slip force 0.76 N (4x below the 3 N tool limit, so buckling stays outside the lumen); EC-22 motors 18,000 rpm max with 1:128 gearhead (~3 Nm); friction-wheel assembly 130 g; teleoperation 500 Hz; master spec from motion study: 28.5 mm stroke, 4.5 N, 13 Hz hand motion (Slave actuators, Teleoperation, Results)",
   "sim_model": "none found (VIST simulator used as the test patient, not a model of SETA)",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "photo",
    "source": "srimathveeravalli2010_design Fig. 2 (patient-side slave, two photographs), p. 164, IJMRCAS 2010 doi:10.1002/rcs.301",
    "source_url": "https://doi.org/10.1002/rcs.301",
    "licence": "publisher copyright",
    "credit": "Srimathveeravalli et al., The International Journal of Medical Robotics and Computer Assisted Surgery (2010), Fig. 2. publisher copyright.",
    "edits": "native extract (the PDF embeds the figure at 500 x 327); no crop; nothing erased; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "buffalo_seta_srimathveeravalli2010_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Slave driving guidewire and catheter into the VIST simulator, simulated fluoroscopy behind",
     "source_key": "srimathveeravalli2010_design",
     "source": "Srimathveeravalli et al., The International Journal of Medical Robotics and Computer Assisted Surgery (2010), Fig. 10, p. 168",
     "source_url": "https://doi.org/10.1002/rcs.301",
     "where": "Fig. 10, p. 168",
     "licence": "publisher copyright"
    },
    {
     "id": "buffalo_seta_srimathveeravalli2010_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Friction-wheel insertion and withdrawal actuator with polyurethane wheels",
     "source_key": "srimathveeravalli2010_design",
     "source": "Srimathveeravalli et al., The International Journal of Medical Robotics and Computer Assisted Surgery (2010), Fig. 3(B), p. 165",
     "source_url": "https://doi.org/10.1002/rcs.301",
     "where": "Fig. 3(B), p. 165",
     "licence": "publisher copyright"
    },
    {
     "id": "buffalo_seta_srimathveeravalli2010_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Steering stage: miniature roller gripper inside its pulley housing",
     "source_key": "srimathveeravalli2010_design",
     "source": "Srimathveeravalli et al., The International Journal of Medical Robotics and Computer Assisted Surgery (2010), Fig. 4(B), p. 165",
     "source_url": "https://doi.org/10.1002/rcs.301",
     "where": "Fig. 4(B), p. 165",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "srimathveeravalli2010_design",
     "doi": "10.1002/rcs.301",
     "url": null,
     "title": "Design and fabrication of a robotic mechanism for remote steering and positioning of interventional devices",
     "year": 2010,
     "venue": "The International Journal of Medical Robotics and Computer Assisted Surgery"
    },
    {
     "key": "ashammagari2016_image",
     "doi": "10.1115/imece2016-65922",
     "url": null,
     "title": "Image Guided Automation of Endovascular Robotic Surgery",
     "year": 2016,
     "venue": "Volume 14: Emerging Technologies; Materials: Genetics to Structures; Safety Engineering and Risk Analysis"
    },
    {
     "key": "rafiitari2014_current",
     "doi": "10.1007/s10439-013-0946-8",
     "url": null,
     "title": "Current and Emerging Robot-Assisted Endovascular Catheterization Technologies: A Review",
     "year": 2014,
     "venue": "Annals of Biomedical Engineering"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (srimathveeravalli2010_design,, hand-downloaded 2026-11-08)",
   "notes": "Predecessor of SAER in the Kesavadas group. No picture: Wiley paper not downloaded. | 2026-11-08 X3: full text read. The rabbit work in the paper is the manual motion-capture study (2 radiologists, 15 datasets), not a robot test, so validation stays phantom. Slave on a passive articulated arm for orientation at the cannula; authors list footprint reduction and a twisting master as open items (Conclusion). The paper's Table 1 surveys 8 earlier systems",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "roses_danieli2022",
   "name": "ROSES",
   "full_name": "ROSES (RObotic System for Endovascular Surgery)",
   "group": "Calabrian High Tech (CHT S.r.l.; G. Danieli) with Magna Graecia University (C. Indolfi, A. Polimeni, S. De Rosa)",
   "group_short": "Calabrian High Tech",
   "family": "commercial",
   "category": "clinical-stage",
   "first_year": 2018,
   "latest_year": 2023,
   "versions": "2018 PCT patent (ref. 6 of indolfi2023_first); robot actuator v1 (motor axes parallel to the gear train), v2 (motors perpendicular, thinner), v3 (36 mm central passage for haemostasis valve and large catheters) (danieli2022_development Fig. 12); disposables for angioplasty (DA), big catheters (DEBC), movable-core guidewires and a tip-curvature catheter; cart with rail and force transducer for endovascular surgery (Fig. 13); first patient 22 Jan 2019; 2023 case report",
   "target_anatomy": "coronary PCI; endovascular surgery, large catheters for aneurysm repair or TAVI (cart version)",
   "devices": [
    "guidewire",
    "therapeutic-device"
   ],
   "devices_driven": "guidewire plus balloon or stent catheter per slave; first-in-human: 6 Fr JR4 guide, 0.014 in BMW wire, 2.0 x 12 mm balloon, 2.5 x 15 mm DES (indolfi2023_first)",
   "n_dof": 3,
   "n_dof_detail": "3 per slave (catheter advance/retract, guidewire advance/retract, common rotation); one console drives up to three slaves (techbriefs 2019 entry)",
   "translation_mechanism": "friction-roller",
   "translation_detail": "friction-roller (3-D-printed disposables convert gear rotation into advance/retract through friction wheels)",
   "rotation_mechanism": "rotating-drive-unit",
   "rotation_detail": "the disposable is rotated by a concentric gear train in the robot actuator (danieli2022_development Sec. 2)",
   "device_range": "0.014 in guidewires to large catheters (36 mm passage in v3); exact Fr range N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "resistance to advancement shown on the console; cart version measures forces opposed by the patient with a force transducer (danieli2022_development abstract, Sec. 3)",
   "haptics_leader": "passive master console with joysticks per track (one for the guidewire, one for devices); no force rendering reported",
   "imaging_compat": "fluoroscopy; cockpit inside or outside the cath lab",
   "sterility": "sterile disposables in contact with the devices, split upper/lower so they can be removed without withdrawing the device (danieli2022_development abstract)",
   "highest_validation": "human",
   "validation_detail": "in vitro tubing and X-ray tests; first patient 22 Jan 2019 (two stents), trials 'still in progress' in 2022 (danieli2022_development Sec. 2); 2023 case report of one 64-year-old patient (R-PCI of a PL branch)",
   "key_numbers": "case: procedure 35 min, contrast 110 mL, stent result satisfactory at 2.5-year follow-up (indolfi2023_first); fluoroscopy time N.R.",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "cleared",
    "grade": "B",
    "kind": "photo",
    "source": "danieli2022_development Fig. 12, centre unit (robot actuator, second edition); https://mdpi-res.com/applmech/applmech-03-00054/article_deploy/html/images/applmech-03-00054-g012.png (article https://doi.org/10.3390/applmech3030054)",
    "source_url": "https://doi.org/10.3390/applmech3030054",
    "licence": "CC BY 4.0",
    "credit": "Danieli et al., Applied Mechanics (2022), Fig. 12. CC BY 4.0.",
    "edits": "full-size MDPI figure image; cropped to the centre unit; not upscaled",
    "file": "pictures/roses_danieli2022.jpg"
   },
   "pictures": [
    {
     "id": "roses_danieli2022_01",
     "status": "cleared",
     "file": "pictures/extra/roses_danieli2022_01.jpg",
     "thumb": "pictures/thumbs/roses_danieli2022_01.jpg",
     "kind": "in-use",
     "caption": "First patient case: operator at the ROSES console, robot actuator on the table",
     "source_key": "danieli2022_development",
     "source": "Danieli et al., Applied Mechanics (2022), Fig. 9(a), p. 6",
     "source_url": "https://doi.org/10.3390/applmech3030054",
     "where": "Fig. 9(a), p. 6",
     "licence": "CC BY 4.0"
    },
    {
     "id": "roses_danieli2022_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "Bedside power unit on its stand and close-up of the functional unit",
     "source_key": "indolfi2023_first",
     "source": "Indolfi et al., European Heart Journal - Case Reports (2023), Fig. 1(B-C), p. 3",
     "source_url": "https://doi.org/10.1093/ehjcr/ytad506",
     "where": "Fig. 1(B-C), p. 3",
     "licence": "CC BY-NC 4.0"
    },
    {
     "id": "roses_danieli2022_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Interventional cardiologist at the ROSES console with joystick and touch screen",
     "source_key": "indolfi2023_first",
     "source": "Indolfi et al., European Heart Journal - Case Reports (2023), graphical abstract, p. 2",
     "source_url": "https://doi.org/10.1093/ehjcr/ytad506",
     "where": "graphical abstract, p. 2",
     "licence": "CC BY-NC 4.0"
    },
    {
     "id": "roses_danieli2022_04",
     "status": "cleared",
     "file": "pictures/extra/roses_danieli2022_04.jpg",
     "thumb": "pictures/thumbs/roses_danieli2022_04.jpg",
     "kind": "photo",
     "caption": "First ROSES prototype ever built, on a wooden bench",
     "source_key": "danieli2022_development",
     "source": "Danieli et al., Applied Mechanics (2022), Fig. 1, p. 2",
     "source_url": "https://doi.org/10.3390/applmech3030054",
     "where": "Fig. 1, p. 2",
     "licence": "CC BY 4.0"
    },
    {
     "id": "roses_danieli2022_05",
     "status": "cleared",
     "file": "pictures/extra/roses_danieli2022_05.jpg",
     "thumb": "pictures/thumbs/roses_danieli2022_05.jpg",
     "kind": "close-up",
     "caption": "Disposable actuator closed and open, showing four friction wheels and spur gears",
     "source_key": "danieli2022_development",
     "source": "Danieli et al., Applied Mechanics (2022), Fig. 6, p. 5",
     "source_url": "https://doi.org/10.3390/applmech3030054",
     "where": "Fig. 6, p. 5",
     "licence": "CC BY 4.0"
    },
    {
     "id": "roses_danieli2022_06",
     "status": "cleared",
     "file": "pictures/extra/roses_danieli2022_06.jpg",
     "thumb": "pictures/thumbs/roses_danieli2022_06.jpg",
     "kind": "in-use",
     "caption": "Early in vitro trial under X-ray with PVC tubing on the angiography table",
     "source_key": "danieli2022_development",
     "source": "Danieli et al., Applied Mechanics (2022), Fig. 8(a), p. 6",
     "source_url": "https://doi.org/10.3390/applmech3030054",
     "where": "Fig. 8(a), p. 6",
     "licence": "CC BY 4.0"
    },
    {
     "id": "roses_danieli2022_07",
     "status": "cleared",
     "file": "pictures/extra/roses_danieli2022_07.jpg",
     "thumb": "pictures/thumbs/roses_danieli2022_07.jpg",
     "kind": "in-use",
     "caption": "First in vitro experiment in water-filled transparent tubing at Catanzaro",
     "source_key": "danieli2022_development",
     "source": "Danieli et al., Applied Mechanics (2022), Fig. 7(a), p. 5",
     "source_url": "https://doi.org/10.3390/applmech3030054",
     "where": "Fig. 7(a), p. 5",
     "licence": "CC BY 4.0"
    },
    {
     "id": "roses_danieli2022_08",
     "status": "cleared",
     "file": "pictures/extra/roses_danieli2022_08.jpg",
     "thumb": "pictures/thumbs/roses_danieli2022_08.jpg",
     "kind": "render",
     "caption": "CAD of the cart arm that holds the robot actuator",
     "source_key": "danieli2022_development",
     "source": "Danieli et al., Applied Mechanics (2022), Fig. 13, p. 9",
     "source_url": "https://doi.org/10.3390/applmech3030054",
     "where": "Fig. 13, p. 9",
     "licence": "CC BY 4.0"
    }
   ],
   "sources": [
    {
     "key": "danieli2022_development",
     "doi": "10.3390/applmech3030054",
     "url": null,
     "title": "Development of Disposables and Accessories for ROSES and Their In Vitro Experimentation",
     "year": 2022,
     "venue": "Applied Mechanics"
    },
    {
     "key": "indolfi2023_first",
     "doi": "10.1093/ehjcr/ytad506",
     "url": null,
     "title": "First-in-human robotic percutaneous coronary intervention by the ROSES robotic system: a case report",
     "year": 2023,
     "venue": "European Heart Journal - Case Reports"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (danieli2022_development, indolfi2023_first); web (techbriefs 2019 contest entry)",
   "notes": "In S8_systems.csv but in no catalogue file before A9. A larger multicentre pivotal trial is described as ongoing in the case report (status not found).",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "rns_beyar2006",
   "name": "RNS",
   "full_name": "Remote Navigation System (RNS)",
   "group": "NaviCath Ltd. (R. Beyar co-founder) with Rambam Medical Center / Technion; clinical sites also Fundeni Hospital and Shaare Zedek (beyar2006_remote p. 296-297)",
   "group_short": "NaviCath",
   "family": "commercial",
   "category": "clinical-stage",
   "first_year": 2005,
   "latest_year": 2006,
   "versions": "2005 concept, design and pre-clinical studies (EuroIntervention 2005;1:340-5, cited as weisz2013_safety ref. 1; not read); 2006 JACC first-in-human pilot (beyar2006_remote); described as the basis of CorPath 200 (crinnion2022_robotics; no full text states that NaviCath became Corindus)",
   "target_anatomy": "coronary PCI",
   "devices": [
    "guidewire",
    "catheter",
    "therapeutic-device"
   ],
   "devices_driven": "standard 0.014-in coronary guidewire and the angioplasty device (balloon or stent); the guiding catheter is hooked to the RNS but not driven; the two devices are interlocked: 'When the guidewire is manipulated, the device is locked at its position and vice versa' (beyar2006_remote p. 296-297). Rapid-exchange devices per wagener2024_features (not stated in beyar2006)",
   "n_dof": 3,
   "n_dof_detail": "3: wire axial and rotation (optionally discrete 30-degree steps), device axial (beyar2006_remote p. 296)",
   "translation_mechanism": "friction-roller",
   "translation_detail": "friction-roller (device: motored roller pair with a passive motion-sensing roller pair behind it, beyar2006_remote p. 296, Fig. 2B; wire: 'mechanical transmission module', type N.R.)",
   "rotation_mechanism": "other",
   "rotation_detail": "wire navigator rotates the wire through a mechanical transmission module (type N.R.) (beyar2006_remote p. 296)",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "no force sensor named: motion-sensing rollers report slippage of the motored rollers and the system halts; 'any force that exceeds a threshold causes system stall' (beyar2006_remote p. 296, 299)",
   "haptics_leader": "no: computerised touch-screen control console and joystick (beyar2006_remote p. 296, Fig. 3); haptic force feedback named as future work (p. 299)",
   "imaging_compat": "standard fluoroscopy screens; the protocol kept the operators at the bedside (beyar2006_remote p. 299)",
   "sterility": "detachable wire and device navigators on a sterile plastic-sheet-covered base; Y-connector in a sterile holder (beyar2006_remote p. 296, Fig. 2 caption); disposable status N.R.",
   "highest_validation": "human",
   "validation_detail": "glass coronary model; anaesthetised sheep (number N.R.), 14 coronary branches, 8 stents implanted; first-in-human pilot: 18 patients (15 men, 3 women) at 3 centres, single-vessel PCI (beyar2006_remote p. 297); 20 lesions per wagener2024_features Table 1 (lesion count not stated in beyar2006)",
   "key_numbers": "wire crossed the lesion in 17 of 18; stent delivered in 15 of 17; technical success 94% (guidewire) and 83% (overall procedure); clinical success 100%; fluoroscopy time 8.8 +- 4.8 vs 9.1 +- 3.5 min with standard technique (NS); catheterisation time 44 +- 32.7 vs 61 +- 19 min; diameter stenosis 60.6 +- 13.5% -> 17.0 +- 7.8%; no in-hospital MACE (beyar2006_remote p. 296-298)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "photo",
    "source": "beyar2006_rns Fig. 2(A) (prototype bedside unit on the patient table, loaded with wire and device), JACC 2006;47:296-300, p. 3,",
    "source_url": "https://doi.org/10.1016/j.jacc.2005.09.024",
    "licence": "publisher copyright (Elsevier / ACC Foundation)",
    "credit": "Beyar et al., Journal of the American College of Cardiology (2006), Fig. 2. publisher copyright (Elsevier / ACC Foundation).",
    "edits": "native extract (embedded 1000 x 1172 holds panels A and B); cropped to panel A without the panel letter; nothing erased; none upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "rns_beyar2006_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Bedside unit on the patient table and operator control unit in the cath lab",
     "source_key": "beyar2006_remote",
     "source": "Beyar et al., Journal of the American College of Cardiology (2006), Fig. 1, p. 2",
     "source_url": "https://doi.org/10.1016/j.jacc.2005.09.024",
     "where": "Fig. 1, p. 2",
     "licence": "publisher copyright"
    },
    {
     "id": "rns_beyar2006_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "leader",
     "caption": "Operator control unit: touch screen and joystick",
     "source_key": "beyar2006_remote",
     "source": "Beyar et al., Journal of the American College of Cardiology (2006), Fig. 3, p. 4",
     "source_url": "https://doi.org/10.1016/j.jacc.2005.09.024",
     "where": "Fig. 3, p. 4",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "beyar2006_remote",
     "doi": "10.1016/j.jacc.2005.09.024",
     "url": null,
     "title": "Remote-Control Percutaneous Coronary Interventions: Concept, Validation, and First-in-Humans Pilot Clinical Trial",
     "year": 2006,
     "venue": "Journal of the American College of Cardiology"
    },
    {
     "key": "wagener2024_features",
     "doi": "10.3390/jcm13185537",
     "url": null,
     "title": "Features and Limitations of Robotically Assisted Percutaneous Coronary Intervention (R-PCI): A Systematic Review of R-PCI",
     "year": 2024,
     "venue": "Journal of Clinical Medicine"
    },
    {
     "key": "chen2023_operating",
     "doi": "10.1109/tmrb.2023.3272049",
     "url": null,
     "title": "The Catheter and Guidewire Operating Systems of Vascular Interventional Surgical Robots: A Systematic Review",
     "year": 2023,
     "venue": "IEEE Transactions on Medical Robotics and Bionics"
    },
    {
     "key": "crinnion2022_robotics",
     "doi": "10.1136/neurintsurg-2021-018096",
     "url": null,
     "title": "Robotics in neurointerventional surgery: a systematic review of the literature",
     "year": 2021,
     "venue": "Journal of NeuroInterventional Surgery"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (beyar2006_remote); secondary (reviews)",
   "notes": "In S8_systems.csv but in no catalogue file before A9 (A3 assigned it to A4; A4 did not add it). Picture is a schematic reproduced in chen2023_operating. | X2 2026-11-08: raised to full text (beyar2006_remote). Two devices loaded but only one moves at a time. Main picture now Beyar Fig. 2(A) photo (old schematic kept as rns_beyar2006_prev.png).",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "polimi_zhang2022",
   "name": "MitraClip stabiliser",
   "full_name": "PoliMi motorised stabiliser for the MitraClip delivery catheter with IRL path planning",
   "group": "Politecnico di Milano, DEIB NEARLab (E. De Momi; X. Zhang, A. Segato) with E. Votta (cardiovascular biomechanics); Horizon 2020 funding",
   "group_short": "Politecnico di Milano",
   "family": "academic",
   "category": "academic",
   "first_year": 2022,
   "latest_year": 2022,
   "versions": "2022 IROS (only)",
   "target_anatomy": "structural heart: transseptal mitral edge-to-edge repair",
   "devices": [
    "catheter",
    "sheath",
    "therapeutic-device"
   ],
   "devices_driven": "Abbott MitraClip delivery catheter, 16 Fr (5.28 mm), 109.5 cm, three pull wires 90 deg apart, inside its sheath (Sec. III-C)",
   "n_dof": 3,
   "n_dof_detail": "3 (medio-lateral bending, antero-posterior bending, insertion in the sheath)",
   "translation_mechanism": "linear-stage+clamp",
   "translation_detail": "linear-stage+clamp (linear actuator on the motorised stabiliser advances the delivery catheter)",
   "rotation_mechanism": "none",
   "rotation_detail": "none; two bending DOF actuated through the handle",
   "device_range": "one clinical delivery system",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R. (3-D-printed PLA)",
   "force_sensing": "none",
   "haptics_leader": "none (autonomous execution of planned path, PID on EM feedback)",
   "imaging_compat": "NDI Aurora EM: 5-DOF tip sensor (0.7 +- 1.4 mm) for feedback, 6-DOF probe (0.48 +- 0.88 mm) for recording",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "patient-specific silicone phantom of femoral vein and IVC with rigid fossa ovalis and mitral replicas registered to Unity (Sec. IV-A)",
   "key_numbers": "closed-loop tip error 1.12 +- 0.75, 1.09 +- 0.68, 1.66 +- 0.62 mm (X/Y/Z), maximum 2.64 mm; PID reduces mean error by 32.68% vs open loop; planned path 60.63 +- 0.96 mm (BC+GAIL) vs 64.99 +- 6.11 mm (manual) (Sec. V)",
   "sim_model": "yes: Unity scene of the patient anatomy with a Cosserat-rod-based catheter kinematic model (zhang2022_robotic Sec. III)",
   "has_sim_model": true,
   "sim2real": "yes",
   "sim2real_detail": "yes (phantom): a BC+GAIL inverse-RL path planner trained in the Unity environment generated the path that the robot executed in the physical phantom with EM closed loop (zhang2022_robotic Sec. IV, Fig. 7)",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "photo",
    "source": "zhang2022_structural_IROS Fig. 4(A) catheter actuation plant (inside the red frame)",
    "source_url": "https://doi.org/10.1109/iros47612.2022.9981676",
    "licence": "publisher copyright (IEEE)",
    "credit": "Zhang et al., 2022 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (2022), Fig. 4. publisher copyright (IEEE).",
    "edits": "native extract (961x568, the whole composite is one raster); cropped to panel A interior; labels and dashed callout lines are baked in and left; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "polimi_zhang2022_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Whole system: actuation plant, motorised stabiliser close-ups, phantom, EM tracker and PCs",
     "source_key": "zhang2022_robotic",
     "source": "Zhang et al., 2022 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (2022), Fig. 4(A)-(G), p. 3",
     "source_url": "https://doi.org/10.1109/iros47612.2022.9981676",
     "where": "Fig. 4(A)-(G), p. 3",
     "licence": "publisher copyright (IEEE)"
    }
   ],
   "sources": [
    {
     "key": "zhang2022_robotic",
     "doi": "10.1109/iros47612.2022.9981676",
     "url": null,
     "title": "Robotic Actuation and Control of a Catheter for Structural Intervention Cardiology",
     "year": 2022,
     "venue": "2022 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS)"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full",
   "notes": "Fills the Politecnico di Milano gap of A3. Only robot in A9 with a simulation-trained planner run on hardware.",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "caranx_smits2025",
   "name": "Caranx TAVI robot",
   "full_name": "Caranx Medical robotic instrument manipulator for transcatheter aortic valve implantation",
   "group": "Caranx Medical (P. Berthet-Rayne, J. Smits, P. Schegg) with Institut Arnault Tzanck, Clinique Pasteur, Emory University, University Hospital Nice",
   "group_short": "Caranx Medical",
   "family": "commercial",
   "category": "commercial",
   "first_year": 2023,
   "latest_year": 2025,
   "versions": "Oct 2023 hybrid-room phantom tests; Dec 2023 - Feb 2024 three in-vivo porcine experiments (CERIMED Marseille); 15 Mar 2024 robot-assisted TAV implantation in a pig; 2025 FRAI paper",
   "target_anatomy": "transfemoral TAVI (aortic valve)",
   "devices": [
    "guidewire",
    "catheter",
    "therapeutic-device"
   ],
   "devices_driven": "Edwards SAPIEN 3 delivery system (flex catheter and handle), intraventricular guidewire, balloon inflation device (Results, Fig. 2)",
   "n_dof": null,
   "n_dof_detail": "N.R. as a number; four drivers: catheter driver, handle driver (flex and balloon fine-positioning wheels), guidewire driver, inflation driver",
   "translation_mechanism": "friction-roller",
   "translation_detail": "friction-roller (friction-wheel transmissions for delivery catheter and guidewire, pretensioned by one screw)",
   "rotation_mechanism": "handle-rotation",
   "rotation_detail": "handle wheels through geared transmissions; catheter roll N.R.",
   "device_range": "one delivery-system type per interface (a reusable base with per-device interfaces envisioned)",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "in-line pressure sensor for pressure-monitored balloon inflation; instrument force sensing N.R.",
   "haptics_leader": "single wireless handheld user-input device; teleoperation from a shielded room",
   "imaging_compat": "fluoroscopy (wireless pedal) and camera test bench; neural-network feature tracking for closed-loop positioning",
   "sterility": "plastic transmission covers on handle wheels; quick-release thumbscrews and spring-loaded sliders; N.R. further",
   "highest_validation": "animal",
   "validation_detail": "3 in-vivo porcine experiments with 20 navigation and balloon-inflation sequences (no implant) and one robot-assisted TAV implantation in a pig; phantom operator study and level-3 supervised autonomy with camera and fluoroscopy feedback (Results)",
   "key_numbers": "fluoroscopy closed-loop positioning 30 runs without failure, final error 0.5 mm median, min-max range 1.03 mm; calibration about 5 s; autonomy up to 2x accuracy and 4x precision vs manual on phantom (Results)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found (network trained on real fluoroscopy data)",
   "picture": {
    "status": "cleared",
    "grade": "B",
    "kind": "clinical-photo",
    "source": "smits2025_tavi_FRAI Fig. 2 (left panel, in-vivo set-up 15 Mar 2024), robotic instrument manipulator region",
    "source_url": "https://doi.org/10.3389/frobt.2025.1650228",
    "licence": "CC BY 4.0",
    "credit": "Smits et al., Frontiers in Robotics and AI (2025), Fig. 2. CC BY 4.0.",
    "edits": "the PDF splits the photo into 3 raster tiles (705x430, 705x288, 284x715): stitched at native size (no vector annotations included), cropped to the manipulator",
    "file": "pictures/caranx_smits2025.jpg"
   },
   "pictures": [
    {
     "id": "caranx_smits2025_01",
     "status": "cleared",
     "file": "pictures/extra/caranx_smits2025_01.jpg",
     "thumb": "pictures/thumbs/caranx_smits2025_01.jpg",
     "kind": "in-use",
     "caption": "Operator teleoperating the TAVI robot with a wireless handheld from a shielded room",
     "source_key": "smits2025_towards",
     "source": "Smits et al., Frontiers in Robotics and AI (2025), Fig. 3, p. 6",
     "source_url": "https://doi.org/10.3389/frobt.2025.1650228",
     "where": "Fig. 3, p. 6",
     "licence": "CC BY 4.0"
    },
    {
     "id": "caranx_smits2025_02",
     "status": "cleared",
     "file": "pictures/extra/caranx_smits2025_02.jpg",
     "thumb": "pictures/thumbs/caranx_smits2025_02.jpg",
     "kind": "setup",
     "caption": "Phantom testbench with tracking camera, monitor and user input device",
     "source_key": "smits2025_towards",
     "source": "Smits et al., Frontiers in Robotics and AI (2025), Fig. 7(a), p. 14",
     "source_url": "https://doi.org/10.3389/frobt.2025.1650228",
     "where": "Fig. 7(a), p. 14",
     "licence": "CC BY 4.0"
    }
   ],
   "sources": [
    {
     "key": "smits2025_towards",
     "doi": "10.3389/frobt.2025.1650228",
     "url": null,
     "title": "Towards autonomous robot-assisted transcatheter heart valve implantation: in vivo teleoperation and phantom validation of AI-guided positioning",
     "year": 2025,
     "venue": "Frontiers in Robotics and AI"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full",
   "notes": "Pre-market company prototype (not in robots_A4). CC BY 4.0 paper.",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "hamlyn_driver_rafiitari2013",
   "name": "Hamlyn driver",
   "full_name": "Hamlyn hands-on robotic catheter driver for learning from demonstration (pre-CathBot)",
   "group": "Imperial College London, Hamlyn Centre (G.-Z. Yang; H. Rafii-Tari, W. Chi, C. J. Payne, J. Liu, C. Riga, C. Bicknell)",
   "group_short": "Imperial",
   "family": "academic",
   "category": "academic",
   "first_year": 2013,
   "latest_year": 2018,
   "versions": "2012 IROS force-feedback system for catheterisation (Payne, title only); 2013 MICCAI GMM/GMR learning with the driver; 2014 MICCAI hierarchical-HMM cooperative catheterisation; 2018 IJCARS non-rigid-registration trajectory transfer; from 2020 the Hamlyn LfD work runs on CathBot (chi2020_collaborative uses 'the CathBot system')",
   "target_anatomy": "aortic arch cannulation (innominate, left common carotid) in silicone phantoms",
   "devices": [
    "catheter"
   ],
   "devices_driven": "one standard catheter (operator handles the guidewire manually in the 2013 shared-control scheme)",
   "n_dof": 2,
   "n_dof_detail": "2 (axial, rotational)",
   "translation_mechanism": "friction-roller",
   "translation_detail": "friction-roller (pair of friction wheels coupled to one servomotor)",
   "rotation_mechanism": "rotating-drive-unit",
   "rotation_detail": "second servomotor rotates the frame that holds the catheter; two Dynamixel MX-28 servomotors, PID (rafiitari2013 Sec. 2.3; chi2018 Sec. Experiments)",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "none on the driver; ATI Mini40 6-DOF sensor under the phantom for evaluation (chi2018)",
   "haptics_leader": "hands-on master: proximal position-sensing unit that reads natural catheter motions (two DOF); no force feedback in these papers",
   "imaging_compat": "NDI Aurora 6-DOF EM sensor at the tip; 2-D projected image for the operator",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "2013: 12 robotic cannulations per learned model (expert and intermediate) across 4 inexperienced operators; 2018: cross-validation over three type-I aortic-arch phantoms under dry, continuous and pulsatile flow, forces vs four experts",
   "key_numbers": "2018 success 98.1% dry and 94.4% continuous flow; mean contact force -33.3% and force SD -70.6% vs manual (chi2018 abstract)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found (policies learned from real phantom demonstrations)",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "photo",
    "source": "payne2012_forcefeedback_IROS Fig. 1 (top photograph: the master-slave force feedback system in situ), IROS 2012",
    "source_url": "https://doi.org/10.1109/iros.2012.6386149",
    "licence": "publisher copyright (IEEE)",
    "credit": "Payne et al., 2012 IEEE/RSJ International Conference on Intelligent Robots and Systems (2012), Fig. 1. publisher copyright (IEEE).",
    "edits": "native extract (1509x686); white margins trimmed to (84,45)-(1426,686); no erasing; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "hamlyn_driver_rafiitari2013_01",
     "status": "cleared",
     "file": "pictures/extra/hamlyn_driver_rafiitari2013_01.jpg",
     "thumb": "pictures/thumbs/hamlyn_driver_rafiitari2013_01.jpg",
     "kind": "setup",
     "caption": "Catheter manipulator at a vascular phantom with flow pumps, camera and EM tracking",
     "source_key": "chi2018_learningbased",
     "source": "Chi et al., International Journal of Computer Assisted Radiology and Surgery (2018), Fig. 4, p. 5",
     "source_url": "https://doi.org/10.1007/s11548-018-1743-5",
     "where": "Fig. 4, p. 5",
     "licence": "CC BY 4.0"
    },
    {
     "id": "hamlyn_driver_rafiitari2013_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Cooperative set-up: catheter driver feeding an aortic-arch phantom under camera view",
     "source_key": "rafiitari2014_hierarchical",
     "source": "Rafii-Tari et al., Lecture Notes in Computer Science (2014), Fig. 1(a), p. 5",
     "source_url": "https://doi.org/10.1007/978-3-319-10404-1_62",
     "where": "Fig. 1(a), p. 5",
     "licence": "publisher copyright (Springer LNCS)"
    },
    {
     "id": "hamlyn_driver_rafiitari2013_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Measurement unit, aortic phantom, proximal position sensor and catheter driving unit",
     "source_key": "rafiitari2013_learningbased",
     "source": "Rafii-Tari et al., Lecture Notes in Computer Science (2013), Fig. 1(a)-(e), p. 4",
     "source_url": "https://doi.org/10.1007/978-3-642-40763-5_46",
     "where": "Fig. 1(a)-(e), p. 4",
     "licence": "publisher copyright (Springer LNCS)"
    },
    {
     "id": "hamlyn_driver_rafiitari2013_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "2012 force-feedback master-slave insertion device held in situ",
     "source_key": "payne2012_force",
     "source": "Payne et al., 2012 IEEE/RSJ International Conference on Intelligent Robots and Systems (2012), Fig. 1 (top), p. 2",
     "source_url": "https://doi.org/10.1109/iros.2012.6386149",
     "where": "Fig. 1 (top), p. 2",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "hamlyn_driver_rafiitari2013_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "2012 user study: operator at the robotic device with phantom and F/T sensor",
     "source_key": "payne2012_force",
     "source": "Payne et al., 2012 IEEE/RSJ International Conference on Intelligent Robots and Systems (2012), Fig. 6, p. 5",
     "source_url": "https://doi.org/10.1109/iros.2012.6386149",
     "where": "Fig. 6, p. 5",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "hamlyn_driver_rafiitari2013_06",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Rendering of the 2012 insertion robot: clutch, over-tube discs, master force sensor",
     "source_key": "payne2012_force",
     "source": "Payne et al., 2012 IEEE/RSJ International Conference on Intelligent Robots and Systems (2012), Fig. 2, p. 3",
     "source_url": "https://doi.org/10.1109/iros.2012.6386149",
     "where": "Fig. 2, p. 3",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "hamlyn_driver_rafiitari2013_07",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD of the 2012 device: clutch, master and slave actuators on one slide",
     "source_key": "payne2012_force",
     "source": "Payne et al., 2012 IEEE/RSJ International Conference on Intelligent Robots and Systems (2012), Fig. 1 (bottom, two embedded strips joined), p. 2",
     "source_url": "https://doi.org/10.1109/iros.2012.6386149",
     "where": "Fig. 1 (bottom, two embedded strips joined), p. 2",
     "licence": "publisher copyright (IEEE)"
    }
   ],
   "sources": [
    {
     "key": "rafiitari2013_learningbased",
     "doi": "10.1007/978-3-642-40763-5_46",
     "url": null,
     "title": "Learning-Based Modeling of Endovascular Navigation for Collaborative Robotic Catheterization",
     "year": 2013,
     "venue": "Lecture Notes in Computer Science"
    },
    {
     "key": "rafiitari2014_hierarchical",
     "doi": "10.1007/978-3-319-10404-1_62",
     "url": null,
     "title": "Hierarchical HMM Based Learning of Navigation Primitives for Cooperative Robotic Endovascular Catheterization",
     "year": 2014,
     "venue": "Lecture Notes in Computer Science"
    },
    {
     "key": "chi2018_learningbased",
     "doi": "10.1007/s11548-018-1743-5",
     "url": null,
     "title": "Learning-based endovascular navigation through the use of non-rigid registration for collaborative robotic catheterization",
     "year": 2018,
     "venue": "International Journal of Computer Assisted Radiology and Surgery"
    },
    {
     "key": "payne2012_force",
     "doi": "10.1109/iros.2012.6386149",
     "url": null,
     "title": "A force feedback system for endovascular catheterisation",
     "year": 2012,
     "venue": "2012 IEEE/RSJ International Conference on Intelligent Robots and Systems"
    },
    {
     "key": "chi2020_collaborative",
     "doi": "10.1109/icra40945.2020.9196912",
     "url": null,
     "title": "Collaborative Robot-Assisted Endovascular Catheterization with Generative Adversarial Imitation Learning",
     "year": 2020,
     "venue": "2020 IEEE International Conference on Robotics and Automation (ICRA)"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (rafiitari2013, rafiitari2014, chi2018); title (Payne 2012)",
   "notes": "Answers A3's open question: the Hamlyn LfD hardware 2013-2018 was this in-house driver, not Sensei/Magellan; Chi 2020 (GAIL) used CathBot.",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "ncsu_sma_crews2012",
   "name": "SMA ablation cath.",
   "full_name": "NC State SMA-actuated robotic ablation catheter (Buckner lab)",
   "group": "North Carolina State University, Mechanical and Aerospace Engineering, Electro-Mechanics Research Laboratory (G. D. Buckner; J. H. Crews, J. H. Wiest); NIH SBIR 5R44HL095227 (no company named)",
   "group_short": "NC State",
   "family": "tip",
   "category": "actuated-device",
   "first_year": 2008,
   "latest_year": 2015,
   "versions": "2008 Veeramani, Buckner et al.: modelling (Smart Mater. Struct.) and design and control (ASME DSCC) of an SMA-actuated robotic catheter, cited by crews2012 and wiest2015 (not read); 2012 JIMSS design optimisation of single-tendon and antagonistic SMA segments in COMSOL with a genetic algorithm, tested on planar wire rigs (crews2012_design, full); 2015 RAS path optimisation and control of a two-segment, eight-tendon catheter (wiest2015_path, full); the lab's later bedside robot is robots_A3 portable_kantu2025 (NC State/NYU), predecessor of LegoBot",
   "target_anatomy": "endocardial RF ablation (left atrium)",
   "devices": [
    "catheter"
   ],
   "devices_driven": "own 2.7 mm catheter with two bending segments, each actuated by four offset SMA tendons (wiest2015 Sec. 2)",
   "n_dof": 4,
   "n_dof_detail": "4 bending (two segments x bend angle and orientation)",
   "translation_mechanism": "tendon/tip-actuation",
   "translation_detail": "tendon/tip-actuation (SMA tendons heated by PWM); no robotic insertion stage",
   "rotation_mechanism": "none",
   "rotation_detail": "none",
   "device_range": "90 and 180 degrees of omnidirectional bending for the proximal and distal segments (wiest2015_path p. 93); own 2.7 mm catheter",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "none",
   "haptics_leader": "joystick on the catheter handle",
   "imaging_compat": "modified EnSite NavX (St. Jude) electrode localisation (wiest2015_path p. 94); trakSTAR magnetic tracking on the 2012 test rigs (crews2012_design p. 552)",
   "sterility": "N.R.",
   "highest_validation": "bench",
   "validation_detail": "bench: catheter submerged in a saline tank with EnSite patch electrodes; path optimisation repeated on four point sets; closed-loop control on one optimised 16-point path (wiest2015_path pp. 95-96); 2012: single-tendon rig (4 tendon offsets x 11 prestrains, 5 tests each) and four antagonistic rigs (crews2012_design p. 552-553)",
   "key_numbers": "path optimisation about 20 s; step response about 2 s with < 10 deg overshoot; mean steady-state tip error 5.5 mm, called unacceptably large by the authors; NavX uncertainty 7.1 +- 3.5 mm, imprecision +- 0.8 mm (wiest2015_path); 2012: optimal bend radius 7.0 mm (single-crystal model) and 7.6 mm (polycrystalline); experimental optimum prestrain about 3.5-4.5% and tendon offset about 1 mm (crews2012_design p. 555-556)",
   "sim_model": "yes: COMSOL finite-element models of SMA-actuated segments coupled to a genetic algorithm in MATLAB (single-crystal and polycrystalline free-energy SMA models), checked on wire rigs (crews2012_design p. 546-557); MATLAB simulations to tune the 2015 path optimiser (wiest2015_path Sec. 2.6)",
   "has_sim_model": true,
   "sim2real": "none-found",
   "sim2real_detail": "none found (simulation used for design optimisation, not for a controller)",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "photo",
    "source": "wiest2015_path Fig. 1 (SMA catheter with handle and joystick); https://cdn.ncbi.nlm.nih.gov/pmc/blobs/efac/4326024/83bb6e389e21/nihms648507f1.jpg (PMC4326024)",
    "source_url": "https://doi.org/10.1016/j.robot.2014.10.019",
    "licence": "publisher copyright (Elsevier; NIH author manuscript in PMC)",
    "credit": "Wiest et al., Robotics and Autonomous Systems (2015), Fig. 1. publisher copyright (Elsevier; NIH author manuscript in PMC).",
    "edits": "PMC figure image as is; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "ncsu_sma_crews2012_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "Catheter segment prototype: solid model and photo of SMA actuators, collets and beam",
     "source_key": "crews2012_design",
     "source": "Crews et al., Journal of Intelligent Material Systems and Structures (2012), Fig. 2(a-b), p. 546",
     "source_url": "https://doi.org/10.1177/1045389x12436738",
     "where": "Fig. 2(a-b), p. 546",
     "licence": "publisher copyright"
    },
    {
     "id": "ncsu_sma_crews2012_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Rendering of the two-segment catheter bent to both sides",
     "source_key": "wiest2015_path",
     "source": "Wiest et al., Robotics and Autonomous Systems (2015), Fig. 3, p. 89",
     "source_url": "https://doi.org/10.1016/j.robot.2014.10.019",
     "where": "Fig. 3, p. 89",
     "licence": "publisher copyright"
    },
    {
     "id": "ncsu_sma_crews2012_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Single-tendon test rig with trakSTAR sensors and the actuator-offset block",
     "source_key": "crews2012_design",
     "source": "Crews et al., Journal of Intelligent Material Systems and Structures (2012), Fig. 8(a-b), p. 552",
     "source_url": "https://doi.org/10.1177/1045389x12436738",
     "where": "Fig. 8(a-b), p. 552",
     "licence": "publisher copyright"
    },
    {
     "id": "ncsu_sma_crews2012_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Antagonistic test rig: flexible beam with two SMA tendons",
     "source_key": "crews2012_design",
     "source": "Crews et al., Journal of Intelligent Material Systems and Structures (2012), Fig. 9, p. 553",
     "source_url": "https://doi.org/10.1177/1045389x12436738",
     "where": "Fig. 9, p. 553",
     "licence": "publisher copyright"
    },
    {
     "id": "ncsu_sma_crews2012_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Catheter submerged in a saline tank with EnSite patch electrodes",
     "source_key": "wiest2015_path",
     "source": "Wiest et al., Robotics and Autonomous Systems (2015), Fig. 11(a), p. 95",
     "source_url": "https://doi.org/10.1016/j.robot.2014.10.019",
     "where": "Fig. 11(a), p. 95",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "crews2012_design",
     "doi": "10.1177/1045389x12436738",
     "url": null,
     "title": "Design optimization of a shape memory alloy–actuated robotic catheter",
     "year": 2012,
     "venue": "Journal of Intelligent Material Systems and Structures"
    },
    {
     "key": "wiest2015_path",
     "doi": "10.1016/j.robot.2014.10.019",
     "url": null,
     "title": "Path optimization and control of a shape memory alloy actuated catheter for endocardial radiofrequency ablation",
     "year": 2015,
     "venue": "Robotics and Autonomous Systems"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (crews2012_design, wiest2015_path journal PDFs)",
   "notes": "Seed-lineage row requested by the coordinator: the BIRO Lab robots (Kantu, LegoBot) descend from Buckner's NC State catheter work. | X2 2026-11-08: first_year 2012 -> 2008 from the lab's earlier SMA robotic-catheter papers cited in both full texts (not read). wiest2015 journal PDF matches the PMC manuscript. | X4 2026-11-08: first_year marked (inferred): Veeramani, Buckner et al. 2008 SMA robotic-catheter papers are cited by crews2012 and wiest2015 but not read",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "siemens_ice_kim2020",
   "name": "ICE manipulator",
   "full_name": "Siemens Healthineers robotic ICE catheter manipulator (proximal and distal units)",
   "group": "Siemens Healthineers Digital Technology & Innovation (Y.-H. Kim, A. Kapoor, T. Mansi) with Houston Methodist (C. H. Lin, Z. Li) and Texas A&M (R. Langari, zero-slack design)",
   "group_short": "Siemens",
   "family": "academic",
   "category": "academic",
   "first_year": 2020,
   "latest_year": 2022,
   "versions": "2020 arXiv (kim2020_towards: 'Back' unit on the handle turns both knobs and gives bulk rotation, 'Front' unit at the introducer gives translation and rotation; 3 pig experiments) / 2022 IJCARS 4-DOF manipulator with automated view recovery (distal and proximal units; 4 pig experiments); 2022 arXiv zero-slack separable ICE robot (debuy2022_design: reusable back portion with four Faulhaber LM 1483-080-11-C linear motors pulling the four tendons directly through 3:1 spools, disposable front portion clipped on with a twist lock and magnetic coupling; 2 bending DOF only, translation/rotation not handled; Materials and Methods, Fig. 1); 2025 arXiv tip-visibility guidance (title)",
   "target_anatomy": "intracardiac echocardiography during EP and structural-heart procedures (incl. transseptal puncture)",
   "devices": [
    "catheter"
   ],
   "devices_driven": "ACUSON AcuNav Volume ICE catheters (Siemens Healthineers)",
   "n_dof": 4,
   "n_dof_detail": "4 (two knob angles, bulk rotation, translation)",
   "translation_mechanism": "other",
   "translation_detail": "other: proximal unit at the introducer sheath gives linear and rotational motion of the shaft (mechanism N.R.)",
   "rotation_mechanism": "handle-rotation",
   "rotation_detail": "distal unit holds the handle, turns both knobs and gives bulk rotation synchronised with the proximal unit",
   "device_range": "one ICE catheter family",
   "footprint_mm": "zero-slack version: 298 mm long, 66 mm diameter (debuy2022 Fig. 1(a) dimension labels); 2020/2022 manipulator N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "none",
   "haptics_leader": "6-DOF analog joystick, no force feedback",
   "imaging_compat": "ICE ultrasound; fluoroscopy-free robot-guided transseptal punctures in animals",
   "sterility": "zero-slack version: reusable actuator back portion, disposable front portion that holds the catheter tendons (debuy2022 Introduction, Fig. 1); 2020/2022 manipulator N.R.",
   "highest_validation": "animal",
   "validation_detail": "4 animal experiments (pig, Houston Methodist MITIE) including 2 fluoro-less robot-guided transseptal punctures; beating-heart phantom (Archetype Medical) (kim2022 Sec. 3)",
   "key_numbers": "view recovery 2.09 +- 0.90 mm and 3.93 +- 2.07 deg in animals, 0.67 +- 0.79 mm and 0.37 +- 0.19 deg in phantom (kim2022 abstract); bench compensation at 60 deg bend 14.8 mm / 31.0 deg -> 5.0 mm / 10.3 deg RMSE (kim2020 arXiv); zero-slack bench, 3 sinusoid trials: tip MAE 4.80 mm / 6.11 deg, 3.31 mm / 3.26 deg with +/-10 deg hysteresis compensation (debuy2022 Table 1)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "clinical-photo",
    "source": "kim2022_ice_IJCARS Fig. 1(b) robotic ICE manipulator (distal and proximal units) on the pig",
    "source_url": "https://doi.org/10.1007/s11548-022-02631-1",
    "licence": "publisher copyright (Springer, (c) CARS 2022)",
    "credit": "Kim et al., International Journal of Computer Assisted Radiology and Surgery (2022), Fig. 1(b). publisher copyright (Springer, (c) CARS 2022).",
    "edits": "native extract (1500x961); cropped to panel (b) without its panel caption; label boxes and arrows on the robot left as is; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "siemens_ice_kim2020_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Robotic ICE manipulator on the pig in the CT suite, operators at the table",
     "source_key": "kim2022_automated",
     "source": "Kim et al., International Journal of Computer Assisted Radiology and Surgery (2022), Fig. 1(a), p. 3",
     "source_url": "https://doi.org/10.1007/s11548-022-02631-1",
     "where": "Fig. 1(a), p. 3",
     "licence": "publisher copyright (Springer, (c) CARS 2022)"
    },
    {
     "id": "siemens_ice_kim2020_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "2020 version on the pig: orange back unit on the handle, front unit at the sheath",
     "source_key": "kim2020_towards",
     "source": "Kim et al. (2020), Fig. 1, top photograph, p. 2 (arXiv 2009.05859)",
     "source_url": "https://doi.org/10.48550/ARXIV.2009.05859",
     "where": "Fig. 1, top photograph, p. 2 (arXiv 2009.05859)",
     "licence": "arXiv non-exclusive distribution licence (authors' copyright)"
    },
    {
     "id": "siemens_ice_kim2020_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Zero-slack separable ICE robot: reusable linear-motor back portion, disposable tendon front portion",
     "source_key": "debuy2022_design",
     "source": "DeBuy et al. (2022), Fig. 1(a)-(c), p. 1 (arXiv 2204.00645)",
     "source_url": "https://doi.org/10.48550/ARXIV.2204.00645",
     "where": "Fig. 1(a)-(c), p. 1 (arXiv 2204.00645)",
     "licence": "arXiv non-exclusive distribution licence (authors' copyright)"
    }
   ],
   "sources": [
    {
     "key": "kim2022_automated",
     "doi": "10.1007/s11548-022-02631-1",
     "url": null,
     "title": "Automated catheter tip repositioning for intra-cardiac echocardiography",
     "year": 2022,
     "venue": "International Journal of Computer Assisted Radiology and Surgery"
    },
    {
     "key": "kim2020_towards",
     "doi": "10.48550/ARXIV.2009.05859",
     "url": null,
     "title": "Towards Automatic Manipulation of Intra-cardiac Echocardiography Catheter",
     "year": 2020,
     "venue": "arXiv"
    },
    {
     "key": "debuy2022_design",
     "doi": "10.48550/ARXIV.2204.00645",
     "url": null,
     "title": "Design and validation of zero-slack separable manipulator for Intracardiac Echocardiography",
     "year": 2022,
     "venue": "arXiv"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (IJCARS 2022; arXiv 2009.05859, PDF ); full (zero-slack, 2-page arXiv 2204.00645, )",
   "notes": "Industrial research prototype, not a product; category academic for that reason. Covers the 'Houston' gap through Houston Methodist. | 2026-11-08 X3: zero-slack paper read in full (it is a 2-page abstract); kim2020 PDF confirms 3 animal experiments in the 2020 version, the row keeps kim2022's 4",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "kcl_cardioxplorer_xu2024",
   "name": "CardioXplorer",
   "full_name": "CardioXplorer open-source modular teleoperated robotic catheter-ablation system",
   "group": "King's College London, School of Biomedical Engineering & Imaging Sciences (K. S. Rhode, R. J. Housden; Z. Xu, A. M. Zeidan) with Guy's and St Thomas' and St George's hospitals",
   "group_short": "KCL",
   "family": "academic",
   "category": "academic",
   "first_year": 2024,
   "latest_year": 2024,
   "versions": "2024 MDPI Robotics (only); sibling KCL robot for transseptal puncture (kcl_tsp_zeidan2023)",
   "target_anatomy": "atrial-fibrillation catheter ablation (pulmonary vein isolation)",
   "devices": [
    "catheter"
   ],
   "devices_driven": "commercial ablation catheters through a catheter-agnostic handle gripper: Thermocool SmartTouch SF and CS, Webster CS EZ Steer (Biosense Webster), Blazer II XP (Boston Scientific) (Sec. 2.1)",
   "n_dof": 3,
   "n_dof_detail": "3 (insertion/retraction, handle rotation, knob)",
   "translation_mechanism": "linear-stage+clamp",
   "translation_detail": "linear-stage+clamp (linear module: NEMA-17 stepper with GT2 belt drive carries the handle, 220 mm insertion depth)",
   "rotation_mechanism": "handle-rotation",
   "rotation_detail": "NEMA-8 stepper (19:1) rotates the handle without limit through a slip ring; servo (12 kg.cm holding torque) turns the knob +-60 deg",
   "device_range": "four commercial ablation catheter models (open-source CAD handles)",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "none on the robot (knob torque of about 6 kg.cm measured during design)",
   "haptics_leader": "joystick, no haptics",
   "imaging_compat": "NDI Aurora EM tracking in tests; phantom imaged on a Siemens Artis Q biplane",
   "sterility": "detachable disposable single-use catheter; N.R. further",
   "highest_validation": "phantom",
   "validation_detail": "benchtop targeting of left pulmonary veins in an AF-patient cardiac phantom; 3 cardiologists and 2 trainees, 5 trials, manual vs robot (Sec. 3)",
   "key_numbers": "task duration -1.59 s with the robot; robotic motion 35.2% smoother for experts than intermediates; jerk improvement vs manual 42.2% (experts) and 13.6% (intermediates); speeds up to +-25 mm/s, 0.5 deg rotation steps up to 9.375 rps; parts cost about USD 700 (abstract, Sec. 2)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "cleared",
    "grade": "A",
    "kind": "photo",
    "source": "xu2024_cardioxplorer_Robotics Fig. 4 left photo (SmartTouch SF catheter in the catheter-agnostic gripper); full-size image https://mdpi-res.com/robotics/robotics-13-00080/article_deploy/html/images/robotics-13-00080-g004.png",
    "source_url": "https://doi.org/10.3390/robotics13050080",
    "licence": "CC BY 4.0",
    "credit": "Xu et al., Robotics (2024), Fig. 4. CC BY 4.0.",
    "edits": "cropped from the 3155x1185 MDPI full-size figure (caption text below the photo excluded); no other edits; not upscaled",
    "file": "pictures/kcl_cardioxplorer_xu2024.jpg"
   },
   "pictures": [
    {
     "id": "kcl_cardioxplorer_xu2024_01",
     "status": "cleared",
     "file": "pictures/extra/kcl_cardioxplorer_xu2024_01.jpg",
     "thumb": "pictures/thumbs/kcl_cardioxplorer_xu2024_01.jpg",
     "kind": "in-use",
     "caption": "Robot driving an ablation catheter into the AF cardiac phantom in the cath lab",
     "source_key": "xu2024_cardioxplorer",
     "source": "Xu et al., Robotics (2024), Fig. 12(a), robot trial, p. 10",
     "source_url": "https://doi.org/10.3390/robotics13050080",
     "where": "Fig. 12(a), robot trial, p. 10",
     "licence": "CC BY 4.0"
    },
    {
     "id": "kcl_cardioxplorer_xu2024_02",
     "status": "cleared",
     "file": "pictures/extra/kcl_cardioxplorer_xu2024_02.jpg",
     "thumb": "pictures/thumbs/kcl_cardioxplorer_xu2024_02.jpg",
     "kind": "photo",
     "caption": "Manufactured robot from above: rotation module on the linear module, with dimensions",
     "source_key": "xu2024_cardioxplorer",
     "source": "Xu et al., Robotics (2024), Fig. 2(a), lower photo, p. 4",
     "source_url": "https://doi.org/10.3390/robotics13050080",
     "where": "Fig. 2(a), lower photo, p. 4",
     "licence": "CC BY 4.0"
    },
    {
     "id": "kcl_cardioxplorer_xu2024_03",
     "status": "cleared",
     "file": "pictures/extra/kcl_cardioxplorer_xu2024_03.jpg",
     "thumb": "pictures/thumbs/kcl_cardioxplorer_xu2024_03.jpg",
     "kind": "photo",
     "caption": "Side view of the manufactured robot holding a catheter handle, with dimensions",
     "source_key": "xu2024_cardioxplorer",
     "source": "Xu et al., Robotics (2024), Fig. 2(a), upper photo, p. 4",
     "source_url": "https://doi.org/10.3390/robotics13050080",
     "where": "Fig. 2(a), upper photo, p. 4",
     "licence": "CC BY 4.0"
    },
    {
     "id": "kcl_cardioxplorer_xu2024_04",
     "status": "cleared",
     "file": "pictures/extra/kcl_cardioxplorer_xu2024_04.jpg",
     "thumb": "pictures/thumbs/kcl_cardioxplorer_xu2024_04.jpg",
     "kind": "render",
     "caption": "CAD rendering of the linear, rotation and catheter-mount modules",
     "source_key": "xu2024_cardioxplorer",
     "source": "Xu et al., Robotics (2024), Fig. 2(b), p. 4",
     "source_url": "https://doi.org/10.3390/robotics13050080",
     "where": "Fig. 2(b), p. 4",
     "licence": "CC BY 4.0"
    },
    {
     "id": "kcl_cardioxplorer_xu2024_05",
     "status": "cleared",
     "file": "pictures/extra/kcl_cardioxplorer_xu2024_05.jpg",
     "thumb": "pictures/thumbs/kcl_cardioxplorer_xu2024_05.jpg",
     "kind": "close-up",
     "caption": "CAD of the adaptive silicone gripper around a catheter knob",
     "source_key": "xu2024_cardioxplorer",
     "source": "Xu et al., Robotics (2024), Fig. 3(b), p. 4",
     "source_url": "https://doi.org/10.3390/robotics13050080",
     "where": "Fig. 3(b), p. 4",
     "licence": "CC BY 4.0"
    },
    {
     "id": "kcl_cardioxplorer_xu2024_06",
     "status": "cleared",
     "file": "pictures/extra/kcl_cardioxplorer_xu2024_06.jpg",
     "thumb": "pictures/thumbs/kcl_cardioxplorer_xu2024_06.jpg",
     "kind": "leader",
     "caption": "Gamepad controller in the control room and responder robot at the catheterisation suite",
     "source_key": "xu2024_cardioxplorer",
     "source": "Xu et al., Robotics (2024), Fig. 8, p. 7",
     "source_url": "https://doi.org/10.3390/robotics13050080",
     "where": "Fig. 8, p. 7",
     "licence": "CC BY 4.0"
    },
    {
     "id": "kcl_cardioxplorer_xu2024_07",
     "status": "cleared",
     "file": "pictures/extra/kcl_cardioxplorer_xu2024_07.jpg",
     "thumb": "pictures/thumbs/kcl_cardioxplorer_xu2024_07.jpg",
     "kind": "in-use",
     "caption": "Three actuation configurations with the resulting catheter tip articulation",
     "source_key": "xu2024_cardioxplorer",
     "source": "Xu et al., Robotics (2024), Fig. 9, p. 7",
     "source_url": "https://doi.org/10.3390/robotics13050080",
     "where": "Fig. 9, p. 7",
     "licence": "CC BY 4.0"
    }
   ],
   "sources": [
    {
     "key": "xu2024_cardioxplorer",
     "doi": "10.3390/robotics13050080",
     "url": null,
     "title": "CardioXplorer: An Open-Source Modular Teleoperative Robotic Catheter Ablation System",
     "year": 2024,
     "venue": "Robotics"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full",
   "notes": "Second KCL robot family next to the A3 neuro manipulator (kclneuro_sadati2025); open-source designs. CC BY 4.0.",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "kcl_tsp_zeidan2023",
   "name": "Transseptal robot",
   "full_name": "KCL force-sensing robot for transseptal puncture (needle and dilator-sheath manipulator)",
   "group": "King's College London (K. Rhode; A. M. Zeidan, Z. Xu, C. E. Mower) with Brunel University London (Y. Noh) and Guy's and St Thomas'",
   "group_short": "KCL",
   "family": "academic",
   "category": "academic",
   "first_year": 2023,
   "latest_year": 2023,
   "versions": "2023 ICRA (only); 2016: KCL 3-DOF MR-compatible multisegment cardiac catheter steering mechanism (Ataollahi 2016 TBME) (Belikov 2024 Fig. 5 AT1; Pescio 2025 Table 2 row 10) (belikov2024_evolution; pescio2025_endovascular); 2015-19: KCL (K. Rhode, H. Liu, J. Back) tendon-driven catheter robot with tension sensing (Back 2015; model-free position control Back 2017), likely the same hardware as Z. Zhang 2019 RA-L cable-driven continuum catheter control with Inria (Belikov 2024 Fig. 5 AT2, JEs) (belikov2024_evolution)",
   "target_anatomy": "interatrial septum (transseptal puncture before left-atrial ablation)",
   "devices": [
    "sheath"
   ],
   "devices_driven": "standard transseptal kit: 8.5 Fr SL0 sheath (St Jude), Torflex dilator (Baylis), BRK-1 Brockenbrough needle (71 cm) (Sec. I)",
   "n_dof": 4,
   "n_dof_detail": "4 actuated (translation and rotation of needle and of dilator-sheath), 2 task-space DOF",
   "translation_mechanism": "linear-stage+clamp",
   "translation_detail": "linear-stage+clamp (lead screws on NEMA-17 steppers M1, M2 move needle and dilator-sheath carriages)",
   "rotation_mechanism": "other",
   "rotation_detail": "NEMA-17 steppers M3, M4 rotate needle and sheath continuously",
   "device_range": "one transseptal kit",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "optoelectronic sensors (New Japan Radio) in the tool fixtures measure contact and puncture force along one axis",
   "haptics_leader": "N.R.",
   "imaging_compat": "N.R.",
   "sterility": "N.R.",
   "highest_validation": "bench",
   "validation_detail": "puncture experiments on anthropomorphic fossa-ovalis tissue models (Sec. IV)",
   "key_numbers": "puncture force 3.97 +- 0.45 N (1 SD), similar to manual values in the literature (abstract)",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "photo",
    "source": "zeidan2023_transseptal_ICRA Fig. 6 (force-testing set-up), left part: the 4-stepper TSP robot",
    "source_url": "https://doi.org/10.1109/icra48891.2023.10160254",
    "licence": "publisher copyright (IEEE version); authors applied CC BY to the accepted manuscript (not obtained)",
    "credit": "Zeidan et al., 2023 IEEE International Conference on Robotics and Automation (ICRA) (2023), Fig. 6. publisher copyright (IEEE version); authors applied CC BY to the accepted manuscript (not obtained).",
    "edits": "native extract (1168x414); cropped to the robot, excluding the label arrow and red puncture inset; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "kcl_tsp_zeidan2023_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Force-testing set-up: robot feeding the TSP kit through a tube to a fossa ovalis model",
     "source_key": "zeidan2023_design",
     "source": "Zeidan et al., 2023 IEEE International Conference on Robotics and Automation (ICRA) (2023), Fig. 6, p. 6",
     "source_url": "https://doi.org/10.1109/icra48891.2023.10160254",
     "where": "Fig. 6, p. 6",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "kcl_tsp_zeidan2023_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD of the robot: needle and dilator-sheath stages, circuit housing, OLED display",
     "source_key": "zeidan2023_design",
     "source": "Zeidan et al., 2023 IEEE International Conference on Robotics and Automation (ICRA) (2023), Fig. 2, upper left view, p. 2",
     "source_url": "https://doi.org/10.1109/icra48891.2023.10160254",
     "where": "Fig. 2, upper left view, p. 2",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "kcl_tsp_zeidan2023_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD of the needle and dilator-sheath fixtures with master switch",
     "source_key": "zeidan2023_design",
     "source": "Zeidan et al., 2023 IEEE International Conference on Robotics and Automation (ICRA) (2023), Fig. 2, upper right view, p. 2",
     "source_url": "https://doi.org/10.1109/icra48891.2023.10160254",
     "where": "Fig. 2, upper right view, p. 2",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "kcl_tsp_zeidan2023_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD top view: four NEMA17 steppers, lead screws and limit switches",
     "source_key": "zeidan2023_design",
     "source": "Zeidan et al., 2023 IEEE International Conference on Robotics and Automation (ICRA) (2023), Fig. 2, lower left view, p. 2",
     "source_url": "https://doi.org/10.1109/icra48891.2023.10160254",
     "where": "Fig. 2, lower left view, p. 2",
     "licence": "publisher copyright (IEEE)"
    },
    {
     "id": "kcl_tsp_zeidan2023_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Exploded CAD of the force-sensing fixtures with cantilever beams and reflectors",
     "source_key": "zeidan2023_design",
     "source": "Zeidan et al., 2023 IEEE International Conference on Robotics and Automation (ICRA) (2023), Fig. 2, lower right view, p. 2 (accepted manuscript, Brunel BURA 2438/28704, embedded 8713 px)",
     "source_url": "https://doi.org/10.1109/icra48891.2023.10160254",
     "where": "Fig. 2, lower right view, p. 2 (accepted manuscript, Brunel BURA 2438/28704, embedded 8713 px)",
     "licence": "publisher copyright (IEEE); accepted manuscript says authors applied CC BY, repository record says IEEE rights"
    }
   ],
   "sources": [
    {
     "key": "zeidan2023_design",
     "doi": "10.1109/icra48891.2023.10160254",
     "url": null,
     "title": "Design and Development of a Novel Force-Sensing Robotic System for the Transseptal Puncture in Left Atrial Catheter Ablation",
     "year": 2023,
     "venue": "2023 IEEE International Conference on Robotics and Automation (ICRA)"
    },
    {
     "key": "belikov2024_evolution",
     "doi": "10.1016/j.jestch.2024.101789",
     "url": null,
     "title": "Evolution and current state of robotic catheters for endovascular surgery: A comprehensive review",
     "year": 2024,
     "venue": "Engineering Science and Technology, an International Journal"
    },
    {
     "key": "pescio2025_endovascular",
     "doi": "10.1080/13645706.2025.2454237",
     "url": null,
     "title": "Endovascular robotics: technical advances and future directions",
     "year": 2025,
     "venue": "Minimally Invasive Therapy & Allied Technologies"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full",
   "notes": "Authors applied CC BY to the accepted manuscript; IEEE version is publisher copyright.",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "gatech_tmvr_qi2023",
   "name": "TMVR delivery",
   "full_name": "Georgia Tech telerobotic transcatheter delivery system for a mitral valve implant",
   "group": "Georgia Institute of Technology, RoboMed Laboratory (J. P. Desai; R. Qi, N. U. Nayar)",
   "group_short": "Georgia Tech",
   "family": "tip",
   "category": "actuated-device",
   "first_year": 2020,
   "latest_year": 2023,
   "versions": "2020 IROS first robotic transcatheter delivery system (title); ICRA 2021, T-MRB 2022 and ICRA 2023 papers of Nayar, Qi and Desai (qi2023 refs. [18]-[20], not read); 2023 RAL telerobotic system: reinforced guide tube in a 24 Fr commercial steerable sheath, stronger actuation, waterproofing, stabiliser, wireless joystick (qi2023, full)",
   "target_anatomy": "mitral valve (transseptal implant delivery)",
   "devices": [
    "catheter",
    "sheath"
   ],
   "devices_driven": "own robotic catheter (5.7 mm OD) on a 1.11 m reinforced guide tube inside a customised steerable outer sheath (VERGO, Duke Extrusion; 6.6 mm ID, 8.3 mm OD, 990.6 mm) (qi2023 Abstract, Sec. IV-A)",
   "n_dof": 4,
   "n_dof_detail": "4 (proximal bending +-90 deg, distal bending +-120 deg, prismatic 70 mm actuatable and restricted to 60 mm, distal torsion +-75 deg; qi2023 Sec. II)",
   "translation_mechanism": "tendon/tip-actuation",
   "translation_detail": "tendon/tip-actuation (distal prismatic joint: the quadlumen tube is advanced by a Pololu 100:1 gearmotor through a lead screw on a linear guide; tendon-driven bending and torsion joints; actuation unit on a stabiliser with a linear guide rail; qi2023 Sec. II)",
   "rotation_mechanism": "tendon-bending",
   "rotation_detail": "tendon-driven distal torsion joint: two antagonistic tendons on a lead-screw holder driven by a DC motor with a 16:1 gearbox (qi2023 Sec. II)",
   "device_range": "own catheter",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "none reported",
   "haptics_leader": "wireless Xbox 360 controller, no haptics",
   "imaging_compat": "N.R.",
   "sterility": "N.R.; waterproofed with two three-way stopcocks for saline introduction (qi2023 Sec. II)",
   "highest_validation": "phantom",
   "validation_detail": "implant delivery in a realistic human cardiovascular phantom (United Biologics) with a ViVitro pulsatile pump (63.1 ml/stroke, 70 beats/min), one demonstration; tube validation with the implant free and against the leaflet; no animal study yet (qi2023 Sec. IV-A, IV-B, V)",
   "key_numbers": "joint tracking RMSE 0.20, 0.74, 0.02 and 0.17 mm (qi2023 Sec. IV-A); Maxon 0.5 W 8 mm DC motors (64:1 bending, 16:1 torsion) and Pololu 100:1 prismatic gearmotor, tendon force up to about 20 N (Sec. II); implant advanced 40 mm under the leaflet (Sec. IV-A); tip deflection about 2 mm during a 15 s hold (Sec. IV-B)",
   "sim_model": "analytical static deflection model of the reinforced quadlumen tube (eqs. 1-10), checked against ANSYS 18.2 FEM and a camera bench test in 12 configurations (qi2023 Sec. III-C, Table I); not a model of the whole robot",
   "has_sim_model": true,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "render",
    "source": "qi2023_telerobotic Fig. 2 (system CAD: actuation system on the stabiliser with the guide tube), RA-L 2023, doi:10.1109/LRA.2023.3265592; native embedded raster p. 2 (3166 x 1136), which carries none of the vector labels",
    "source_url": "https://doi.org/10.1109/LRA.2023.3265592",
    "licence": "publisher copyright (IEEE)",
    "credit": "Qi et al., IEEE Robotics and Automation Letters (2023), Fig. 2. publisher copyright (IEEE).",
    "edits": "native extract; cropped to the actuation system and stabiliser (guide tube cut at the right edge so the detail insets stay out); 40 px of white added at the top as margin (render background is pure white); no other edits; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "gatech_tmvr_qi2023_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Telerobotic delivery system in a human cardiovascular phantom, side view",
     "source_key": "qi2023_telerobotic",
     "source": "Qi et al., IEEE Robotics and Automation Letters (2023), Fig. 1, p. 1",
     "source_url": "https://doi.org/10.1109/lra.2023.3265592",
     "where": "Fig. 1, p. 1",
     "licence": "publisher copyright"
    },
    {
     "id": "gatech_tmvr_qi2023_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Implant delivery setup: robot, pulsatile pump, phantom and gamepad",
     "source_key": "qi2023_telerobotic",
     "source": "Qi et al., IEEE Robotics and Automation Letters (2023), Fig. 7(a), p. 6",
     "source_url": "https://doi.org/10.1109/lra.2023.3265592",
     "where": "Fig. 7(a), p. 6",
     "licence": "publisher copyright"
    },
    {
     "id": "gatech_tmvr_qi2023_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Robotic catheter with bending section beside a one-cent coin",
     "source_key": "qi2023_telerobotic",
     "source": "Qi et al., IEEE Robotics and Automation Letters (2023), Fig. 7(b), p. 6",
     "source_url": "https://doi.org/10.1109/lra.2023.3265592",
     "where": "Fig. 7(b), p. 6",
     "licence": "publisher copyright"
    },
    {
     "id": "gatech_tmvr_qi2023_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Guide tube and implant inside the heart phantom, two views",
     "source_key": "qi2023_telerobotic",
     "source": "Qi et al., IEEE Robotics and Automation Letters (2023), Fig. 7(c-d), p. 6",
     "source_url": "https://doi.org/10.1109/lra.2023.3265592",
     "where": "Fig. 7(c-d), p. 6",
     "licence": "publisher copyright"
    },
    {
     "id": "gatech_tmvr_qi2023_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Earlier steerable catheter delivering the mitral clip inside a phantom heart",
     "source_key": "nayar2020_towards",
     "source": "Nayar et al., 2020 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (2020), Fig. 9(a), p. 6 (IROS 2020 predecessor)",
     "source_url": "https://doi.org/10.1109/iros45743.2020.9341551",
     "where": "Fig. 9(a), p. 6 (IROS 2020 predecessor)",
     "licence": "publisher copyright"
    },
    {
     "id": "gatech_tmvr_qi2023_06",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "setup",
     "caption": "Tendon actuation stages on a perforated plate with the catheter, earlier prototype",
     "source_key": "nayar2020_towards",
     "source": "Nayar et al., 2020 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (2020), Fig. 7, p. 4",
     "source_url": "https://doi.org/10.1109/iros45743.2020.9341551",
     "where": "Fig. 7, p. 4",
     "licence": "publisher copyright"
    },
    {
     "id": "gatech_tmvr_qi2023_07",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Assembled catheter with bending and torsion joints and implant module",
     "source_key": "nayar2020_towards",
     "source": "Nayar et al., 2020 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (2020), Fig. 6(a), p. 4",
     "source_url": "https://doi.org/10.1109/iros45743.2020.9341551",
     "where": "Fig. 6(a), p. 4",
     "licence": "publisher copyright"
    },
    {
     "id": "gatech_tmvr_qi2023_08",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "Renderings of the implant delivery module with clip closed and opened",
     "source_key": "nayar2020_towards",
     "source": "Nayar et al., 2020 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (2020), Fig. 5, p. 3",
     "source_url": "https://doi.org/10.1109/iros45743.2020.9341551",
     "where": "Fig. 5, p. 3",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "qi2023_telerobotic",
     "doi": "10.1109/lra.2023.3265592",
     "url": null,
     "title": "Telerobotic Transcatheter Delivery System for Mitral Valve Implant",
     "year": 2023,
     "venue": "IEEE Robotics and Automation Letters"
    },
    {
     "key": "nayar2020_towards",
     "doi": "10.1109/iros45743.2020.9341551",
     "url": null,
     "title": "Towards the Development of a Robotic Transcatheter Delivery System for Mitral Valve Implant",
     "year": 2020,
     "venue": "2020 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS)"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (IEEE PDF, 2026-10-14)",
   "notes": "Tip-actuated device, so category actuated-device; Desai's COAST and balloon guidewires are in robots_A5. F4 2026-10-14: no clean photo of the whole robot in the paper (Figs. 1, 7(a), 8 show the unit small or with pointers).",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "dupont_teer_pistorius2025",
   "name": "TEER robot",
   "full_name": "Boston Children's robotic drive for transcatheter edge-to-edge mitral repair (MitraClip cartridges on a universal catheter drive)",
   "group": "Boston Children's Hospital / Harvard Medical School (P. E. Dupont; L. Pistorius, N. U. Nayar, P. Tran) with UCSF (S. Elmariah)",
   "group_short": "Boston Children's",
   "family": "academic",
   "category": "academic",
   "first_year": 2025,
   "latest_year": 2026,
   "versions": "2025 arXiv; 2026 RAL; the universal drive itself is announced for a separate letter",
   "target_anatomy": "mitral valve (TEER)",
   "devices": [
    "sheath",
    "therapeutic-device"
   ],
   "devices_driven": "Abbott MitraClip NTR through an Edwards PASCAL Precision transseptal sheath; manual handles replaced by transmission cartridges (Sec. II)",
   "n_dof": 8,
   "n_dof_detail": "8 used (transseptal sheath 3, intermediate sheath 3, device sheath 2); drive supports up to four telescoping sheaths with up to four motorised inputs each",
   "translation_mechanism": "linear-stage+clamp",
   "translation_detail": "linear-stage+clamp (device-agnostic carts translate each cartridge)",
   "rotation_mechanism": "handle-rotation",
   "rotation_detail": "motor-driven worm gears for bending and rotation; clamp on the handle for device-sheath roll",
   "device_range": "procedure-specific cartridges on device-agnostic carts",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "none reported",
   "haptics_leader": "game controller (haptic device input supported by the ROS 2 software)",
   "imaging_compat": "N.R.",
   "sterility": "N.R.",
   "highest_validation": "phantom",
   "validation_detail": "silicone mitral model (United Biologics); one operator; 5 manual and 5 robotic trials per step test; 30 manual and 30 robotic clip deliveries, 10 per segment A1P1, A2P2, A3P3 (Sec. IV)",
   "key_numbers": "segment 2 robotic time 52% of manual; mean clip placement error from 3 mm to below 1 mm for segments 2 and 3; inadvertent clip rotation 28 +- 4 deg manual vs 6 +- 7 deg robotic; speed limits 5.46 deg/s flexure, 14.56 deg/s roll, 6 mm/s translation",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "photo",
    "source": "pistorius2026_teer_RAL Fig. 4(b) robotic clip delivery system (drive system with three cartridges)",
    "source_url": "https://doi.org/10.1109/lra.2026.3698357",
    "licence": "publisher copyright (IEEE; NIH author manuscript PMC13271658)",
    "credit": "Pistorius et al., IEEE Robotics and Automation Letters (2026), Fig. 4(b). publisher copyright (IEEE; NIH author manuscript PMC13271658).",
    "edits": "native extract (2050x1926); cropped above the label arrow, so the wheels are cut at the bottom; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "dupont_teer_pistorius2025_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Robotic clip delivery system at the silicone heart model with game controller",
     "source_key": "pistorius2026_using",
     "source": "Pistorius et al., IEEE Robotics and Automation Letters (2026), Fig. 4(b), p. 5",
     "source_url": "https://doi.org/10.1109/lra.2026.3698357",
     "where": "Fig. 4(b), p. 5",
     "licence": "publisher copyright (IEEE; NIH author manuscript PMC13271658)"
    },
    {
     "id": "dupont_teer_pistorius2025_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "Top view of three cartridges on carts with leadscrews, motors and grippers",
     "source_key": "pistorius2026_using",
     "source": "Pistorius et al., IEEE Robotics and Automation Letters (2026), Fig. 2(c), p. 2",
     "source_url": "https://doi.org/10.1109/lra.2026.3698357",
     "where": "Fig. 2(c), p. 2",
     "licence": "publisher copyright (IEEE; NIH author manuscript PMC13271658)"
    },
    {
     "id": "dupont_teer_pistorius2025_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Manual TEER handles beside their robotic cartridges, degrees of freedom colour-coded",
     "source_key": "pistorius2026_using",
     "source": "Pistorius et al., IEEE Robotics and Automation Letters (2026), Fig. 2(a)-(b), p. 2",
     "source_url": "https://doi.org/10.1109/lra.2026.3698357",
     "where": "Fig. 2(a)-(b), p. 2",
     "licence": "publisher copyright (IEEE; NIH author manuscript PMC13271658)"
    },
    {
     "id": "dupont_teer_pistorius2025_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD of the cartridge lock clamp and gear connection to the cart",
     "source_key": "pistorius2026_using",
     "source": "Pistorius et al., IEEE Robotics and Automation Letters (2026), Fig. 2(d), p. 2",
     "source_url": "https://doi.org/10.1109/lra.2026.3698357",
     "where": "Fig. 2(d), p. 2",
     "licence": "publisher copyright (IEEE; NIH author manuscript PMC13271658)"
    }
   ],
   "sources": [
    {
     "key": "pistorius2026_using",
     "doi": "10.1109/lra.2026.3698357",
     "url": null,
     "title": "Using Robotics to Improve Transcatheter Edge-to-Edge Repair of the Mitral Valve",
     "year": 2026,
     "venue": "IEEE Robotics and Automation Letters"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full",
   "notes": "Distinct from the Dupont autonomous intracardiac catheter (robots_A3 dupont_fagogenis2019).",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "levshai_menshikov2023",
   "name": "LevshAi",
   "full_name": "LevshAi intelligent robotic motion-copying system for endovascular neurosurgery",
   "group": "Neurosputnik LLC with MIPT, NUST MISIS and Moscow State University (I. Menshikov, A. Bernadotte)",
   "group_short": "Neurosputnik",
   "family": "commercial",
   "category": "commercial",
   "first_year": 2023,
   "latest_year": 2023,
   "versions": "2023 IEEE CBS system paper (full); 2023 ICARA personalised 3-D vascular simulator (title)",
   "target_anatomy": "cerebral vessels (endovascular neurosurgery, aneurysm coiling)",
   "devices": [
    "guidewire",
    "catheter"
   ],
   "devices_driven": "catheters and guidewires; dispenser for gel; coil installation on the control side (Sec. II)",
   "n_dof": null,
   "n_dof_detail": "N.R. (axial movement and rotation of catheters)",
   "translation_mechanism": "other",
   "translation_detail": "other: stepper transmission mechanisms (type N.R.)",
   "rotation_mechanism": "not-reported",
   "rotation_detail": "stepper transmission (N.R.)",
   "device_range": "N.R.",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "optical motion encoders and piezo sensors along the catheter detect twisting and vibration (Sec. II-C)",
   "haptics_leader": "leader identical to a real catheter and torquer; stepper motors render twist resistance, linear miniature solenoids render wall contact, LED force scale",
   "imaging_compat": "X-ray fluoroscopy; AI processing of fluoroscopy",
   "sterility": "N.R.",
   "highest_validation": "bench",
   "validation_detail": "tested by surgeons of the Russian Endovascular Neuro Society, qualitative only (Sec. I)",
   "key_numbers": "N.R.",
   "sim_model": "personalised 3-D vascular simulator built from patient images (menshikov2023_preoperative, title; CBS Sec. II-E)",
   "has_sim_model": true,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "C",
    "kind": "photo",
    "source": "menshikov2023_levshai_CBS Fig. 6 (preclinical trial photo), hardware box at the bottom edge",
    "source_url": null,
    "licence": "publisher copyright (IEEE)",
    "credit": "menshikov2023_levshai_CBS Fig. 6 (preclinical trial photo), hardware box at the bottom edge. Licence: publisher copyright (IEEE).",
    "edits": "the PDF splits the photo into 7 raster tiles: stitched at native size, a 3-px tile seam filled from the neighbouring column, cropped to the hardware box (people excluded); not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "levshai_menshikov2023_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "in-use",
     "caption": "Preclinical trial: control unit on the table with the 3D vessel simulation projected",
     "source_key": "menshikov2023_intelligent",
     "source": "Menshikov et al., 2022 IEEE International Conference on Cyborg and Bionic Systems (CBS) (2023), Fig. 6, p. 5",
     "source_url": "https://doi.org/10.1109/cbs55922.2023.10115398",
     "where": "Fig. 6, p. 5",
     "licence": "publisher copyright"
    },
    {
     "id": "levshai_menshikov2023_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "System drawing: executive manipulator at the patient, surgeon-side control unit",
     "source_key": "menshikov2023_intelligent",
     "source": "Menshikov et al., 2022 IEEE International Conference on Cyborg and Bionic Systems (CBS) (2023), Fig. 1, p. 3",
     "source_url": "https://doi.org/10.1109/cbs55922.2023.10115398",
     "where": "Fig. 1, p. 3",
     "licence": "publisher copyright"
    }
   ],
   "sources": [
    {
     "key": "menshikov2023_intelligent",
     "doi": "10.1109/cbs55922.2023.10115398",
     "url": null,
     "title": "Intelligent Robotic Motion Copying System LevshAi for Neurosurgical Endovascular Operations with Haptic Feedback and Preoperative Personalized Simulation",
     "year": 2023,
     "venue": "2022 IEEE International Conference on Cyborg and Bionic Systems (CBS)"
    },
    {
     "key": "menshikov2023_preoperative",
     "doi": "10.1109/icara56516.2023.10125981",
     "url": null,
     "title": "Preoperative Personalized Vascular 3D Simulator of the Intelligent Robotic Ecosystem LevshAI for Endovascular Neurosurgery",
     "year": 2023,
     "venue": "2023 9th International Conference on Automation, Robotics and Applications (ICARA)"
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (CBS 2023)",
   "notes": "Company prototype with university co-authors; no quantitative results or hardware photo in the paper.",
   "maintainers_own": false,
   "found_by": "gap"
  },
  {
   "schema_version": 1,
   "id": "wpi_flanagan2024",
   "name": "WPI telescoping",
   "full_name": "WPI MQP robotic platform for telescoping neurointerventional catheters (proof of concept)",
   "group": "Worcester Polytechnic Institute, undergraduate MQP team (advisors Y. Zheng, Z. Zhang)",
   "group_short": "WPI",
   "family": "academic",
   "category": "academic",
   "first_year": 2024,
   "latest_year": 2024,
   "versions": "2024 MQP report; builds on earlier WPI MQP guidewire robots (stepper-and-solenoid design; BLDC roller design) described in its background",
   "target_anatomy": "neurointervention",
   "devices": [
    "catheter"
   ],
   "devices_driven": "modular telescoping catheters of several sizes",
   "n_dof": 2,
   "n_dof_detail": "2 (linear and rotational per catheter module)",
   "translation_mechanism": "friction-roller",
   "translation_detail": "friction-roller (driven and support wheels on a board; 3-wheel, straight and S-shaped layouts tested)",
   "rotation_mechanism": "rotating-drive-unit",
   "rotation_detail": "the whole wheel board rotates through a gear and slip ring (BLDC motors with FOC drivers)",
   "device_range": "various catheter sizes (N.R.)",
   "footprint_mm": "N.R.",
   "mass_kg": "N.R.",
   "force_sensing": "none",
   "haptics_leader": "N.R. (micro-ROS over Wi-Fi, EM sensor integration)",
   "imaging_compat": "N.R.",
   "sterility": "N.R.",
   "highest_validation": "bench",
   "validation_detail": "several 3-D-printed prototypes built and iterated; qualitative tests only",
   "key_numbers": "N.R.",
   "sim_model": "none found",
   "has_sim_model": false,
   "sim2real": "none-found",
   "sim2real_detail": "none found",
   "picture": {
    "status": "not-cleared",
    "grade": "B",
    "kind": "photo",
    "source": "flanagan2024_robotic Fig. 12 (completed 3-wheel test prototype), native embedded image p. 15 of the MQP report",
    "source_url": "https://digital.wpi.edu/show/j96024883",
    "licence": "N.R. (WPI student report on digital.wpi.edu; rights statement not checked)",
    "credit": "Flanagan et al., 2024, Fig. 12. N.R. (WPI student report on digital.wpi.edu; rights statement not checked).",
    "edits": "native extract; no crop; not upscaled",
    "file": null
   },
   "pictures": [
    {
     "id": "wpi_flanagan2024_01",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "Final prototype: rotational gear, alignment wheels, PCB platform and encoder",
     "source_key": "flanagan2024_robotic",
     "source": "Flanagan et al. (2024), Fig. 17, p. 20",
     "source_url": "https://digital.wpi.edu/show/j96024883",
     "where": "Fig. 17, p. 20",
     "licence": "N.R. (WPI student report on digital.wpi.edu; rights statement not checked)"
    },
    {
     "id": "wpi_flanagan2024_02",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD of the final prototype with primary and secondary slip rings",
     "source_key": "flanagan2024_robotic",
     "source": "Flanagan et al. (2024), Fig. 18, p. 20",
     "source_url": "https://digital.wpi.edu/show/j96024883",
     "where": "Fig. 18, p. 20",
     "licence": "N.R. (WPI student report on digital.wpi.edu; rights statement not checked)"
    },
    {
     "id": "wpi_flanagan2024_03",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Device platform with red rotational gear, wiring and driver board",
     "source_key": "flanagan2024_robotic",
     "source": "Flanagan et al. (2024), Fig. 14, p. 17",
     "source_url": "https://digital.wpi.edu/show/j96024883",
     "where": "Fig. 14, p. 17",
     "licence": "N.R. (WPI student report on digital.wpi.edu; rights statement not checked)"
    },
    {
     "id": "wpi_flanagan2024_04",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "close-up",
     "caption": "Acrylic top with support-wheel and end-wheel bearings on the trolley",
     "source_key": "flanagan2024_robotic",
     "source": "Flanagan et al. (2024), Fig. 16, p. 19",
     "source_url": "https://digital.wpi.edu/show/j96024883",
     "where": "Fig. 16, p. 19",
     "licence": "N.R. (WPI student report on digital.wpi.edu; rights statement not checked)"
    },
    {
     "id": "wpi_flanagan2024_05",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "photo",
     "caption": "Early 3-wheel testing prototype with driven wheel and connecting rods",
     "source_key": "flanagan2024_robotic",
     "source": "Flanagan et al. (2024), Fig. 7, p. 12",
     "source_url": "https://digital.wpi.edu/show/j96024883",
     "where": "Fig. 7, p. 12",
     "licence": "N.R. (WPI student report on digital.wpi.edu; rights statement not checked)"
    },
    {
     "id": "wpi_flanagan2024_06",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD of the first rotational design: slip ring, rotational and driven gears",
     "source_key": "flanagan2024_robotic",
     "source": "Flanagan et al. (2024), Fig. 11, p. 15",
     "source_url": "https://digital.wpi.edu/show/j96024883",
     "where": "Fig. 11, p. 15",
     "licence": "N.R. (WPI student report on digital.wpi.edu; rights statement not checked)"
    },
    {
     "id": "wpi_flanagan2024_07",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD of the S-shaped catheter layout in the testing prototype",
     "source_key": "flanagan2024_robotic",
     "source": "Flanagan et al. (2024), Fig. 9, p. 13",
     "source_url": "https://digital.wpi.edu/show/j96024883",
     "where": "Fig. 9, p. 13",
     "licence": "N.R. (WPI student report on digital.wpi.edu; rights statement not checked)"
    },
    {
     "id": "wpi_flanagan2024_08",
     "status": "not-cleared",
     "file": null,
     "thumb": null,
     "kind": "render",
     "caption": "CAD of the alignment wheels and endplate on the main platform",
     "source_key": "flanagan2024_robotic",
     "source": "Flanagan et al. (2024), Fig. 10, p. 14",
     "source_url": "https://digital.wpi.edu/show/j96024883",
     "where": "Fig. 10, p. 14",
     "licence": "N.R. (WPI student report on digital.wpi.edu; rights statement not checked)"
    }
   ],
   "sources": [
    {
     "key": "flanagan2024_robotic",
     "doi": null,
     "url": "https://digital.wpi.edu/show/j96024883",
     "title": "A Robotic Platform for Neurointervention",
     "year": 2024,
     "venue": null
    }
   ],
   "read_level": "full",
   "read_level_detail": "full (MQP report)",
   "notes": "Student report, no peer review; included because it documents a built prototype (coordinator rule).",
   "maintainers_own": false,
   "found_by": "gap"
  }
 ]
}