Catheter Robot Atlas

Commercial and clinical-stage systems · sentante_sentante2022

SENTANTE

SENTANTE Endovascular Robotic System
UAB Inovatyvi Medicina (Sentante) · 2022–2026
SENTANTE: main picture1 / 6
Not cleared for distribution. https://sentante.com/wp-content/uploads/2025/12/Frame-2087328849-min.jpg (home page https://sentante.com/). Licence: press image (Sentante). Picture grade B.
Family
Commercial and clinical-stage systems (commercial)
Devices
3 coaxial: one guidewire 0.014-0.035 in + two over-the-wire catheters 2-8 Fr; standard off-the-shelf devices
Degrees of freedom
2 per device (advance, rotate), 3 devices
Push
Other drives
Twist
Rotating drive unit
Tested up to
Human
Sim-to-real
None found — No simulation-trained controller found for this robot.

Testing

Highest level
Human
What was tested
ESSENTIAL first-in-human started July 2024, Paula Stradins hospital Riga (press; NCT06537947); 6 pigs; 24 GLP remote animal procedures and transatlantic cadaver thrombectomy (press)
Key numbers
pig study: no angiographic vessel injury; minimal trauma 3/16 vessels at necropsy (huistra2026_evaluation abstract). ESSENTIAL: 100% technical success, 0 device complications (unite.ai, unverified press).

Mechanism

Push (translation)
other: paired sterile cassettes grip device and travel on rails
Twist (rotation)
cassette rotation
Device range
N.R.
Target anatomy
peripheral, visceral; vertebral stenting in pigs; stroke thrombectomy shown on cadaver models (press)

Sensing and interface

Force sensing
yes: bedside unit measures manipulation force
Leader and haptics
yes: leader uses real catheter/guidewire at workstation, reflects measured force
Imaging
remote workstation outside X-ray field
Sterility
3 pairs of sterile single-use cassettes

Size

Footprint (mm)
N.R.
Mass (kg)
N.R.

Simulation

Simulation model
none found
Sim-trained controller
none found

Versions

Lineage
single platform; CE mark reported 2026-05-22; commercial rollout announced 2026-08-20 (unite.ai only, lower certainty)

Sources

  1. Evaluation of Fully Teleoperated Robotic Endovascular Interventions with Haptic Feedback: The SENTANTE Endovascular Robotic System · CardioVascular and Interventional Radiology, 2026 · doi:10.1007/s00270-026-04375-w [huistra2026_evaluation]
  2. Robotic Systems in Cardiovascular Interventions: Evolving Platforms and the Path Forward · Methodist DeBakey Cardiovascular Journal, 2025 · doi:10.14797/mdcvj.1652 [mandhumula2025_robotic]
  3. Robot-Assisted Cardiovascular Interventions · Journal of the Society for Cardiovascular Angiography & Interventions, 2025 · doi:10.1016/j.jscai.2025.102568 [george2025_robot]

Notes

Notes
Only teleoperated system with true device-handle haptics among commercial systems found.

This record

Read level
full — full text on disk (survey txt) for huistra; web for CE
Picture
https://sentante.com/wp-content/uploads/2025/12/Frame-2087328849-min.jpg (home page https://sentante.com/) ↗ — licence: press image (Sentante); grade B
Picture changes
cropped (930,455)-(2350,1405) of 2800x1680 (bedside rail unit + mast + monitor, C-arm cut away)
Found by
commercial: Search of commercial and clinical-stage systems.
Data
JSON · YAML: records/robots/sentante_sentante2022.yaml
Correction
Suggest a correction [repository not created yet]
← Sensei XSETA →