 "name": "Catheter Robot Atlas",
 "generated": "2026-11-11",
 "schema": "review.schema.json",
 "metadata_licence": "to be decided by the maintainers (CC0-1.0 or CC-BY-4.0)",
 "pictures": "Each picture keeps its owner's licence (see picture.licence); only cleared pictures are published.",
 "count": 34,
 "reviews": [
  {
   "schema_version": 1,
   "key": "bonatti2014_robotic",
   "year": 2014,
   "venue": "Nat. Rev. Cardiol.",
   "title": "Robotic technology in cardiovascular medicine",
   "doi": "10.1038/nrcardio.2014.23",
   "n_robots": "N.R. (abstract)",
   "robot_pictures": "unknown (full text not read)",
   "taxonomy_axes": "abstract: by field (interventional cardiology, electrophysiology, endovascular surgery, minimally invasive cardiac surgery, laparoscopic vascular surgery)",
   "commercial": "unknown (full text not read)",
   "academic": "unknown (full text not read)",
   "actuated_tip": "unknown (full text not read)",
   "magnetic": "unknown (full text not read)",
   "simulation": "unknown (full text not read)",
   "sim2real": "unknown (full text not read)",
   "pages": "10 (11(5):266-275)",
   "n_refs": "54 (Crossref)",
   "citations": "86 (COCI, V1 2026-11-07)",
   "read_level": "abstract (Europe PMC, PMID 24663088, R4A 2026-11-07)"
  },
  {
   "schema_version": 1,
   "key": "rafiitari2014_current",
   "year": 2014,
   "venue": "Ann. Biomed. Eng.",
   "title": "Current and Emerging Robot-Assisted Endovascular Catheterization Technologies: A Review",
   "doi": "10.1007/s10439-013-0946-8",
   "n_robots": "18 (6 commercial in Table 3 + 12 research in Table 4)",
   "robot_pictures": "partial: Fig. 1 milestone strip pictures 4 commercial systems (Stereotaxis magnetic navigation, Hansen Sensei X, Hansen Magellan, Catheter Robotics Amigo; Corindus CorPath 200 is named on the strip without a picture); Fig. 5 photos of 3 research robots (Tanimoto, Thakur, Payne); Fig. 4 is fluoroscopy (PDF p. 2 (698) and p. 13 (709) checked by R4A 2026-11-07; was 'no photo of any commercial robot')",
   "taxonomy_axes": "Table 3/4 columns: vascular vs EP, distal/proximal force sensing, force feedback, human-robot interface, 3D navigation, steerable catheter",
   "commercial": "yes (Sensei X, Magellan, Niobe, Amigo, CorPath, CGCI)",
   "academic": "yes",
   "actuated_tip": "yes (Sensei, Magellan, Amigo)",
   "magnetic": "yes (Niobe, CGCI)",
   "simulation": "skill-assessment simulators only (Table 2); no robot simulation",
   "sim2real": "no",
   "pages": 19,
   "n_refs": 118,
   "citations": 268,
   "read_level": "full (survey/lit/txt; Fig. 1 checked on the PDF page, R4A 2026-11-07)"
  },
  {
   "schema_version": 1,
   "key": "ali2016_steerable",
   "year": 2016,
   "venue": "IEEE Trans. Biomed. Eng.",
   "title": "Steerable Catheters in Cardiology: Classifying Steerability and Assessing Future Challenges",
   "doi": "10.1109/TBME.2016.2525785",
   "n_robots": "N.R. (abstract: existing, patented and experimental designs)",
   "robot_pictures": "unknown (full text not read)",
   "taxonomy_axes": "abstract: force generation in the tip (electric, thermal, magnetic) vs force transmission to the tip (hydraulic chamber, mechanic cable)",
   "commercial": "unknown (full text not read)",
   "academic": "unknown (full text not read)",
   "actuated_tip": "yes (abstract)",
   "magnetic": "yes (magnetic actuation, abstract)",
   "simulation": "unknown (full text not read)",
   "sim2real": "unknown (full text not read)",
   "pages": "15 (63(4):679-693)",
   "n_refs": "68 (Crossref)",
   "citations": "71 (COCI, V1 2026-11-07)",
   "read_level": "abstract (Europe PMC, PMID 26863645, R4A 2026-11-07)"
  },
  {
   "schema_version": 1,
   "key": "hu2018_steerable",
   "year": 2018,
   "venue": "Comput. Assist. Surg.",
   "title": "Steerable catheters for minimally invasive surgery: a review and future directions",
   "doi": "10.1080/24699322.2018.1526972",
   "n_robots": "N.R. (abstract)",
   "robot_pictures": "unknown (full text not read)",
   "taxonomy_axes": "abstract: four actuation groups (tendon-driven, magnetic navigation, soft-material-driven, hybrid)",
   "commercial": "unknown (full text not read)",
   "academic": "unknown (full text not read)",
   "actuated_tip": "yes (abstract)",
   "magnetic": "yes (abstract)",
   "simulation": "unknown (full text not read)",
   "sim2real": "unknown (full text not read)",
   "pages": "21 (23(1):21-41)",
   "n_refs": "146 (Crossref)",
   "citations": "158 (COCI, V1 2026-11-07)",
   "read_level": "abstract (Europe PMC, PMID 30497292, R4A 2026-11-07)"
  },
  {
   "schema_version": 1,
   "key": "hwang2020_review",
   "year": 2020,
   "venue": "Intell. Serv. Robot.",
   "title": "A review of magnetic actuation systems and magnetically actuated guidewire- and catheter-based microrobots for vascular interventions",
   "doi": "10.1007/s11370-020-00311-0",
   "n_robots": "4 commercial magnetic navigation systems (Niobe, Genesis, CGCI, Aeon Phocus; Sec. 3) plus academic magnetic guidewires (Fig. 7, 6 panels) and catheters (Fig. 8, 7 panels)",
   "robot_pictures": "yes: Niobe (Fig. 3a), Genesis (Fig. 4a, render), CGCI magnet chamber (Fig. 5), Aeon Phocus (Fig. 6a, b)",
   "taxonomy_axes": "magnetic actuation systems x guidewire/catheter microrobots",
   "commercial": "4 magnetic navigation systems",
   "academic": "magnetically actuated guidewires and catheters from academic groups",
   "actuated_tip": "yes",
   "magnetic": "yes (scope)",
   "simulation": "no",
   "sim2real": "no",
   "pages": 14,
   "n_refs": 105,
   "citations": 165,
   "read_level": "full (2026-10-14; first author is Hwang, not Li: key corrected from li2020_magnetic)"
  },
  {
   "schema_version": 1,
   "key": "crinnion2022_robotics",
   "year": 2022,
   "venue": "J. NeuroInterv. Surg.",
   "title": "Robotics in neurointerventional surgery: a systematic review of the literature",
   "doi": "10.1136/neurintsurg-2021-018096",
   "n_robots": "5 (Table 1: Sensei, Niobe, Amigo, Magellan, CorPath 200) + GRX",
   "robot_pictures": "yes: Fig. 1-3 photos of Magellan arm, CorPath 200 arm, CorPath GRX arm and cassette (numbered parts)",
   "taxonomy_axes": "PRISMA over neuro studies; Table 1 = indication, control panel, advantages/disadvantages",
   "commercial": "yes",
   "academic": "no",
   "actuated_tip": "Sensei, Magellan (Table 1)",
   "magnetic": "Niobe (Table 1 only)",
   "simulation": "no",
   "sim2real": "no",
   "pages": 7,
   "n_refs": 55,
   "citations": 48,
   "read_level": "full (JATS XML)"
  },
  {
   "schema_version": 1,
   "key": "zhao2022_remote",
   "year": 2022,
   "venue": "Quant. Imaging Med. Surg.",
   "title": "Remote vascular interventional surgery robotics: a literature review",
   "doi": "10.21037/qims-21-792",
   "n_robots": "24 institutions in Table 1 (columns field, haptic feedback, force sensing, autonomous delivery); the text names 5 commercial systems (Magellan, CorPath GRX, R-One, Genesis RMN with Niobe, Sensei) and academic robots it does not count",
   "robot_pictures": "some: 9 robots pictured, photos or renders (Fig. 2 Guo's three generations, Fig. 3 SJTU robot, Fig. 4 CASIA and Hansen manipulators, Fig. 5 CorPath GRX, Fig. 7 CathROB, Fig. 8 Genesis RMN, Fig. 17 two MR-compatible robots)",
   "taxonomy_axes": "general vascular vs EP robots; basic vs secondary functions; linear platform vs friction wheel; force sensing distal vs proximal; master controllers heterogeneous vs isomorphic; safety strategies; control methods; autonomy",
   "commercial": "yes (text only)",
   "academic": "yes (main focus)",
   "actuated_tip": "mention (Artisan catheter, EP catheter handles)",
   "magnetic": "mention (Genesis RMN with Niobe, Fig. 8)",
   "simulation": "no (VR training mentioned)",
   "sim2real": "no",
   "pages": "23 (12(4):2552-2574)",
   "n_refs": 113,
   "citations": 58,
   "read_level": "full (lit/txt + PDF, X1 2026-11-08); search Web of Science, IEEE Xplore, Wiley, Science Direct, Springer Link, 1997 to December 2020; CC BY-NC-ND 4.0"
  },
  {
   "schema_version": 1,
   "key": "chen2023_operating",
   "year": 2023,
   "venue": "IEEE T-MRB",
   "title": "The Catheter and Guidewire Operating Systems of Vascular Interventional Surgical Robots: A Systematic Review",
   "doi": "10.1109/TMRB.2023.3272049",
   "n_robots": "17 rows in Table I (clinical studies; robot systems merged down rows)",
   "robot_pictures": "partial: Fig. 1 chevron chain of five companies with photos; Fig. 3-9 mechanism examples",
   "taxonomy_axes": "hardware (mechanisms, contact force, master, haptics) vs algorithm (bilateral control, safety, skill evaluation); clinical application",
   "commercial": "yes",
   "academic": "yes",
   "actuated_tip": "no",
   "magnetic": "12 hits, minor",
   "simulation": "no (1 hit)",
   "sim2real": "no",
   "pages": 16,
   "n_refs": 109,
   "citations": 22,
   "read_level": "full (V_ extract, structure + text)"
  },
  {
   "schema_version": 1,
   "key": "duan2023_progress",
   "year": 2023,
   "venue": "Micromachines",
   "title": "Technical and Clinical Progress on Robot-Assisted Endovascular Interventions: A Review",
   "doi": "10.3390/mi14010197",
   "n_robots": "15 (Table 1: CorPath, Magellan + 13 academic groups)",
   "robot_pictures": "minimal: Fig. 6 CorPath GRX photo; Fig. 3 mechanism schematics; no per-robot photos",
   "taxonomy_axes": "Table 1 = translation mechanism (friction roller / clamp) x rotation (clamped wheel / bionic finger) x teleoperation (isometric / non-isometric)",
   "commercial": "yes (2)",
   "academic": "yes (13)",
   "actuated_tip": "no",
   "magnetic": "mention only",
   "simulation": "mention (1 hit)",
   "sim2real": "no",
   "pages": "N.R. (open PDF pending)",
   "n_refs": 130,
   "citations": 50,
   "read_level": "full (JATS XML)"
  },
  {
   "schema_version": 1,
   "key": "morag2023_barriers",
   "year": 2023,
   "venue": "Tech. Vasc. Interv. Radiol.",
   "title": "Overcoming Barriers and Advancements in Endovascular Robotics: A Review of Systems and Developments",
   "doi": "10.1016/j.tvir.2023.100918",
   "n_robots": "N.R. (abstract names Magellan and LIBERTY)",
   "robot_pictures": "unknown (Elsevier)",
   "taxonomy_axes": "abstract: adoption barriers (room space, set-up time, range of compatible tools, cost); Magellan and LIBERTY as examples",
   "commercial": "yes (Magellan, LIBERTY; abstract)",
   "academic": "unknown (full text not read)",
   "actuated_tip": "unknown (full text not read)",
   "magnetic": "unknown (full text not read)",
   "simulation": "unknown (full text not read)",
   "sim2real": "unknown (full text not read)",
   "pages": "N.R. (article 100918)",
   "n_refs": "14 (Crossref)",
   "citations": "6 (COCI, V1 2026-11-07)",
   "read_level": "abstract (Europe PMC, PMID 38071030, R4A 2026-11-07)"
  },
  {
   "schema_version": 1,
   "key": "najafi2023_current",
   "year": 2023,
   "venue": "Cardiovasc. Intervent. Radiol.",
   "title": "Current State of Robotics in Interventional Radiology",
   "doi": "10.1007/s00270-023-03421-1",
   "n_robots": "6 endovascular systems in Table 1 (Sensei, Magellan, CorPath GRX, R-One, Niobe ES, Amigo) + 6 platforms under development named in the text (LIBERTY, Endoways, Coral, AngioBot, Aopeng, WeMed) + non-vascular CT/MRI robots (Table 3)",
   "robot_pictures": "no: Fig. 1 is a drawing of manual, robotic and MRI-guided set-ups (p. 10 (558))",
   "taxonomy_axes": "Table 1 columns: institute, regulatory status, compatibility with off-the-shelf equipment, DOF, procedures; Table 2 clinical studies; vascular vs non-vascular",
   "commercial": "yes (Table 1)",
   "academic": "MR-safe and MR-conditional research platforms in text (refs 41-43)",
   "actuated_tip": "no",
   "magnetic": "Niobe ES (Table 1)",
   "simulation": "simulators for training mentioned in the discussion",
   "sim2real": "no",
   "pages": 13,
   "n_refs": "89 (Crossref)",
   "citations": "48 (COCI, R4A 2026-11-07)",
   "read_level": "full (, fetched by R4A 2026-11-07, CC BY 4.0)"
  },
  {
   "schema_version": 1,
   "key": "pore2023_autonomous",
   "year": 2023,
   "venue": "IEEE Trans. Robot.",
   "title": "Autonomous Navigation for Robot-Assisted Intraluminal and Endovascular Procedures: A Systematic Review",
   "doi": "10.1109/TRO.2023.3269384",
   "n_robots": "65 studies (motion planning, not robots)",
   "robot_pictures": "no",
   "taxonomy_axes": "level of autonomy x planning family (node / sampling / optimization / learning)",
   "commercial": "partial",
   "academic": "partial",
   "actuated_tip": "no",
   "magnetic": "no",
   "simulation": "in silico as validation tier",
   "sim2real": "no",
   "pages": 20,
   "n_refs": 204,
   "citations": 54,
   "read_level": "full"
  },
  {
   "schema_version": 1,
   "key": "ren2023_critical",
   "year": 2023,
   "venue": "IEEE Sens. J.",
   "title": "The Critical Technologies of Vascular Interventional Robotic Catheterization: A Review",
   "doi": "10.1109/JSEN.2023.3320356",
   "n_robots": "14 robots (Table IV)",
   "robot_pictures": "partial: Fig. 1 slave robot photos (SenseiX etc.), Fig. 2-3 mechanism examples",
   "taxonomy_axes": "axial delivery, twisting, force sensing (Table II), feedback (Table III), robots by application (Table I-IV)",
   "commercial": "yes",
   "academic": "yes",
   "actuated_tip": "yes (Sensei)",
   "magnetic": "yes (Niobe, 56 hits)",
   "simulation": "minor (9 hits)",
   "sim2real": "no",
   "pages": 19,
   "n_refs": 184,
   "citations": 26,
   "read_level": "full (txt)"
  },
  {
   "schema_version": 1,
   "key": "yang2023_magnetically",
   "year": 2023,
   "venue": "Adv. Intell. Syst.",
   "title": "Magnetically Actuated Continuum Medical Robots: A Review",
   "doi": "10.1002/aisy.202200416",
   "n_robots": "N.R. (abstract)",
   "robot_pictures": "unknown (Wiley)",
   "taxonomy_axes": "abstract: tethered (intravascular microcatheters) vs untethered magnetic devices; design, fabrication, modelling, control",
   "commercial": "unknown (full text not read)",
   "academic": "unknown (full text not read)",
   "actuated_tip": "unknown (full text not read)",
   "magnetic": "yes (abstract)",
   "simulation": "unknown (full text not read)",
   "sim2real": "unknown (full text not read)",
   "pages": "N.R. (article 2200416)",
   "n_refs": "221 (Crossref)",
   "citations": "128 (COCI, V1 2026-11-07)",
   "read_level": "abstract (Crossref, DOI content negotiation, R4A 2026-11-07)"
  },
  {
   "schema_version": 1,
   "key": "belikov2024_evolution",
   "year": 2024,
   "venue": "Eng. Sci. Technol. Int. J.",
   "title": "Evolution and current state of robotic catheters for endovascular surgery: A comprehensive review",
   "doi": "10.1016/j.jestch.2024.101789",
   "n_robots": "57 models in 130 versions (Sec. 2; PRISMA, Google Scholar, January 2011 to December 2023; 197 reports); includes Amigo, CorPath 200, CorPath GRX, Niobe with V-drive, Sensei X, Magellan, R-One, CathBot, ROSES, Althea (Figs. 5-6)",
   "robot_pictures": "none: every version is drawn as a pictogram table of its mechanisms (Figs. 4-6); no photograph or drawing of a robot (all 9 figures checked on the PDF, embedded images per page)",
   "taxonomy_axes": "mechanism classification of the leader (primary) and follower (secondary) units, actuation and feedback channels (Fig. 3: rollers, grab mechanism, spool; clamp rotation, whole-part rotation, sliding grips; conveyor belts, sliding rollers, differential; tip: pneumatic, magnetic, motor); per version: DoF, simultaneous translation and rotation, quick release, tip movement type, level of development 0-5 (3D model, phantom, animal, cadaver, human, commercial) (Sec. 4.3); ranges of motion and speed (Fig. 7); trueness and precision of translation and rotation (Fig. 8); correlation of mechanisms with these parameters (Fig. 9); problems and trends (Table 1)",
   "commercial": "yes, 7 in the timeline (Amigo, CorPath 200, CorPath GRX, Niobe with V-drive, Sensei X, Magellan, R-One)",
   "academic": "yes (most of the 57 models)",
   "actuated_tip": "yes: tip movement type coded per version; specialized catheters in < 15 % of versions (tendon: Sensei, Magellan, FU, AT, QI, YI; precurved tubes COAST; pneumatic RO; shape-memory polymer HE; magnetic WO1.1) (Sec. 4.9)",
   "magnetic": "part: Niobe with V-drive and one magnetic tip (WO1.1); no other magnetic navigation system",
   "simulation": "no (one numerical error-compensation model mentioned, Sec. 6)",
   "sim2real": "no",
   "pages": "17 (vol. 57, article 101789)",
   "n_refs": 211,
   "citations": "3 (COCI, V1 2026-11-07)",
   "read_level": "full (lit/txt + PDF, X1 2026-11-08); CC BY 4.0; supplementary material (Supplementary Methods, Supplementary Table 1, figure-reading notes) not downloaded"
  },
  {
   "schema_version": 1,
   "key": "li2024_design",
   "year": 2024,
   "venue": "IEEE T-MRB",
   "title": "Robotic Systems Design in Endovascular Treatment",
   "doi": "10.1109/TMRB.2024.3377374",
   "n_robots": "9 commercial (Table I) + academic mechanism examples",
   "robot_pictures": "yes for commercial: Fig. 1 photo collage A-H of eight commercial systems; Fig. 3-7 schematics; Fig. 8 radar chart",
   "taxonomy_axes": "follower / leader / control; Table I columns: intended use, imaging, haptics, off-the-shelf compatibility, motion types, controller, intuitiveness, presence, limitations",
   "commercial": "yes",
   "academic": "yes (mechanisms)",
   "actuated_tip": "yes (Sensei, Magellan)",
   "magnetic": "yes (Niobe, Genesis; 54 hits)",
   "simulation": "no",
   "sim2real": "no; RL mentioned in autonomy section",
   "pages": 17,
   "n_refs": 160,
   "citations": 17,
   "read_level": "full (V_ extract)"
  },
  {
   "schema_version": 1,
   "key": "alekseeva2025_design",
   "year": 2025,
   "venue": "J. Field Robot.",
   "title": "The Design of Endovascular Robots for Cardiac Interventions: A Survey",
   "doi": "10.1002/rob.22480",
   "n_robots": "85 rows in Tables 1-15: 62 systems (11 commercial, 51 academic = 45 cardiac + 6 neurovascular) and 23 robotic tools (Sec. 2.2, p. 1917; abstract; Sec. 6)",
   "robot_pictures": "line drawings by one illustrator (Acknowledgments), no photographs: 52 of the 62 systems (Figs. 8-11, 13, 15-18, 21; not drawn: CorPath 200, Genesis RMN, Sensei X, Payne 2012, P. Zhang 2011, H. Liu 2017, L. Li 2018, Naudin 2019, LevshAi, T. Cao 2024; MicroVAST and ARMM share Fig. 21(d)) and 7 of the 23 tools (Fig. 19); drive mechanisms Figs. 12, 14; leader controls Fig. 22 (drawing style checked on PDF pp. 24 and 26)",
   "taxonomy_axes": "three control classes: proximal tip (passive), hybrid, distal tip (active) (Sec. 3); Tables 1-15 give the same 9 columns for all 85 rows: number of arms, DoF, tool manipulation principle, tool compatibility, human-machine interface, feedback, visualization, TRL (medical TRL of Rier et al. 2022); papers per system per year (Figs. 5-7); controls and visualization (X-ray, MRI, ultrasound, 3D) (Sec. 4); CorPath GRX field experience, reasons for low adoption, vision of collaborative 6-DoF robots that also change and assemble tools (Sec. 5)",
   "commercial": "yes, 11 (Amigo, CorPath 200, CorPath GRX, R-One, Niobe, Genesis RMN, Sensei X, Magellan, Navion, CGCI, Aeon Phocus; Tables 1, 11, 14)",
   "academic": "yes, 51 (Tables 2-10, 12-14; TRL3 for most, TRL5 for 11, TRL7 for Choi 2021, RVIR, REIS, ROSES)",
   "actuated_tip": "yes: 23 robotic tools (tendon: COAST, Qi 2019, A. Gao 2017, Y. Yan 2023; fluid pressure: MALICA, multi-actuator soft catheters, VINE; shape-memory polymer: He 2018, Mattmann; IPMC; peristaltic) and the pull-wire Sensei X and Magellan (Tables 11-15)",
   "magnetic": "yes: Niobe, Genesis RMN, CGCI, Aeon Phocus, Navion; MicroVAST, ARMM, Z. Yang 2021, Kim 2022, hybrid of Cha (OctoMag); magnetic tools (Tables 11-15)",
   "simulation": "excluded: vascular simulators and learning-based navigation papers excluded at screening (Sec. 2.2)",
   "sim2real": "no",
   "pages": "49 (42(5):1914-1962)",
   "n_refs": "323 (Crossref reference-count)",
   "citations": 4,
   "read_level": "full (lit/txt + PDF, X1 2026-11-08); search: Scopus, no date limit, run October 2024, English only; 277 papers; data available from the corresponding author on request (Data Availability Statement)"
  },
  {
   "schema_version": 1,
   "key": "cheng2025_continuum_mitral",
   "year": 2025,
   "venue": "IEEE Access",
   "title": "Continuum Robotic Catheter Systems for Transcatheter Mitral Valve Procedures: A Technical Review",
   "doi": "10.1109/access.2025.3548273",
   "n_robots": "N.R.",
   "robot_pictures": "not read",
   "taxonomy_axes": "continuum catheter systems for mitral procedures",
   "commercial": "N.R.",
   "academic": "N.R.",
   "actuated_tip": "yes (scope)",
   "magnetic": "N.R.",
   "simulation": "N.R.",
   "sim2real": "N.R.",
   "pages": 14,
   "n_refs": 79,
   "citations": 4,
   "read_level": "title/listing only"
  },
  {
   "schema_version": 1,
   "key": "george2025_robot",
   "year": 2025,
   "venue": "J. Soc. Cardiovasc. Angiogr. Interv.",
   "title": "Robot-Assisted Cardiovascular Interventions",
   "doi": "10.1016/j.jscai.2025.102568",
   "n_robots": "CorPath GRX, R-One + 7 emerging systems (Table 2)",
   "robot_pictures": "not seen (text only; PDF pending)",
   "taxonomy_axes": "Table 1 clinical studies; Table 2 new systems by stage",
   "commercial": "yes",
   "academic": "yes (7 emerging)",
   "actuated_tip": "no",
   "magnetic": "6 hits",
   "simulation": "no",
   "sim2real": "no",
   "pages": "N.R.",
   "n_refs": 59,
   "citations": 2,
   "read_level": "full text (txt), figures not checked"
  },
  {
   "schema_version": 1,
   "key": "grand2025_challenges",
   "year": 2025,
   "venue": "Science Robotics",
   "title": "The grand challenges of learning medical robot autonomy",
   "doi": "10.1126/scirobotics.adz8279",
   "n_robots": "n/a (Viewpoint; no endovascular system named)",
   "robot_pictures": "none (Fig. 1 is a schematic of teleoperation, classical and learned autonomy)",
   "taxonomy_axes": "sense-think-act structure of automation; challenges of learned autonomy: data (incl. sim-to-real gap), edge cases, collaborative autonomy and trust, testing, verification and regulation; translational pathway (start where teleoperation is already justified; emergent procedures such as stroke thrombectomy; steep learning curves)",
   "commercial": "n/a",
   "academic": "n/a",
   "actuated_tip": "n/a",
   "magnetic": "n/a",
   "simulation": "yes, one paragraph: simulation yields data but 'often struggles with the sim-to-real gap'",
   "sim2real": "mention (data challenge)",
   "pages": "5 (10(104):eadz8279)",
   "n_refs": 31,
   "citations": 2,
   "read_level": "full (lit/txt + PDF, X1 2026-11-08)"
  },
  {
   "schema_version": 1,
   "key": "konda2025_robotically",
   "year": 2025,
   "venue": "Science Robotics",
   "title": "Robotically steerable guidewires - Current trends and future directions",
   "doi": "10.1126/scirobotics.adt7461",
   "n_robots": "40 papers in Table 2 (22 design and actuation, 8 sensing, 10 control), one row per paper; magnetic, tendon-driven and one pneumatic guidewire, plus motorized drives for passive wires; devices not counted by the review",
   "robot_pictures": "some: Fig. 3 photos of 3 magnetically steered guidewires and Fig. 4 photos of 3 tendon-driven guidewires (COAST family); Fig. 2 drive-mechanism renders; no commercial robot",
   "taxonomy_axes": "actuation: magnetic vs motorized (passive wire on a motorized unit; active tendon tube), pneumatic; motion basis translation, bending, bending-plane rotation (Fig. 2); modelling (PCC, Cosserat, FEM, data-driven); sensing; control; evaluation hierarchy custom phantom to in vivo; Table 2 columns: focus, paper, actuation, active guidewire, feedback, modelling, control, demonstration, animal model, target application",
   "commercial": "no (only the manual Artiria steerable guidewire and Bendit microcatheter named)",
   "academic": "mention (motorized units that drive passive wires, Table 2)",
   "actuated_tip": "yes (core of the review)",
   "magnetic": "yes (magnetically steerable guidewires and their field sources; no commercial system named)",
   "simulation": "SOFA with SofaGym and simulated vasculature for RL path planning (Control section)",
   "sim2real": "no explicit transfer analysis",
   "pages": "15 (10(105):eadt7461)",
   "n_refs": 158,
   "citations": 4,
   "read_level": "full (lit/txt + PDF, X1 2026-11-08); no search method stated"
  },
  {
   "schema_version": 1,
   "key": "mandhumula2025_robotic",
   "year": 2025,
   "venue": "Methodist DeBakey Cardiovasc. J.",
   "title": "Robotic Systems in Cardiovascular Interventions: Evolving Platforms and the Path Forward",
   "doi": "10.14797/mdcvj.1652",
   "n_robots": "~19-24 systems in Table 1 (roller / gripper / tendon / magnetic groups)",
   "robot_pictures": "yes: Fig. 1 commercial photos (CorPath GRX, 200, Liberty, R-One, Sensei, Magellan...); Fig. 2 pre-commercial and academic (Sentante, Choi roller cartridge...)",
   "taxonomy_axes": "actuation mechanism (roller, gripper, tendon, magnetic) x DOF x catheter driving x tip articulation x feedback x compatible devices",
   "commercial": "yes",
   "academic": "yes (pre-commercial + academic)",
   "actuated_tip": "yes",
   "magnetic": "yes (Niobe, Genesis, Navion; 29 hits)",
   "simulation": "no",
   "sim2real": "no",
   "pages": 19,
   "n_refs": 126,
   "citations": 0,
   "read_level": "full (JATS XML)"
  },
  {
   "schema_version": 1,
   "key": "miyachi2025_robotics",
   "year": 2025,
   "venue": "J. Neuroendovasc. Ther.",
   "title": "Robotics for Neuroendovascular Therapy",
   "doi": "10.5797/jnet.ra.2024-0112",
   "n_robots": "3-4 (CorPath GRX, 2001 catheter system, neuro support robot)",
   "robot_pictures": "yes: Fig. 1-3 photos of 3 systems; Fig. 5 telesurgery set-up",
   "taxonomy_axes": "history and systems; 13 limitations",
   "commercial": "yes",
   "academic": "yes",
   "actuated_tip": "no",
   "magnetic": "3 hits",
   "simulation": "1 hit",
   "sim2real": "no",
   "pages": "N.R.",
   "n_refs": 40,
   "citations": 3,
   "read_level": "full (JATS XML)"
  },
  {
   "schema_version": 1,
   "key": "peng2025_robotic",
   "year": 2025,
   "venue": "SmartBot",
   "title": "Robotic-Assisted Endovascular Embolization: Progress and Future Perspectives",
   "doi": "10.1002/smb2.12009",
   "n_robots": "N.R. (no table; tethered actuated-tip and magnetic devices and untethered magnetic microrobots described; no commercial or bedside robot)",
   "robot_pictures": "none of a robot: Fig. 3 micrographs and schematics of 3 device tips; Figs. 4-5 untethered robots; Figs. 1, 6 schematics",
   "taxonomy_axes": "disease models; embolic agents (coils, particulates, liquid and gel); robot-assisted embolization tethered vs untethered (magnetic particles, microcoils); tip actuation and magnetic field sources",
   "commercial": "no",
   "academic": "no",
   "actuated_tip": "yes (hydraulic, magnetic, variable-stiffness tips, Sec. 4.1)",
   "magnetic": "yes (fringe-field navigation, electromagnet and permanent-magnet systems, untethered robots)",
   "simulation": "no",
   "sim2real": "no",
   "pages": "16 (1(1):e12009)",
   "n_refs": 136,
   "citations": "19 (COCI, V1 2026-11-07)",
   "read_level": "full (lit/txt + PDF, X1 2026-11-08); CC BY"
  },
  {
   "schema_version": 1,
   "key": "pescio2025_endovascular",
   "year": 2025,
   "venue": "Minim. Invasive Ther. Allied Technol.",
   "title": "Endovascular robotics: technical advances and future directions",
   "doi": "10.1080/13645706.2025.2454237",
   "n_robots": "29: 12 commercial or company-stage (Table 1: Genesis, Niobe, Sensei X2, Magellan, CorPath GRX, CorPath 200, R-One+, Amigo RCS, Nanoflex, Flux One, Sentante, Liberty) and 17 research platforms (Table 2, one row per platform and year)",
   "robot_pictures": "some: Fig. 1 timeline (2007-2022) pictures 11 commercial systems with company credit lines (Genesis not pictured); no picture of a research platform",
   "taxonomy_axes": "Tables 1-2 share 7 columns: system, application, endovascular instruments, controller set-up, haptic feedback, 3D navigation, description; research trends MRI compatibility, human-robot interaction, autonomy (levels of Yang, IEC/TR 60601-4-1, Haidegger, Pore); reasons for commercial failure (Sec. 2.1)",
   "commercial": "yes (12, Table 1)",
   "academic": "yes (17, Table 2)",
   "actuated_tip": "yes (steerable catheters in the instruments column; Jayender SMA, Fu pull-wire, He variable stiffness)",
   "magnetic": "yes (Genesis, Niobe, Nanoflex, Flux One)",
   "simulation": "one paragraph: deep RL trained in a finite-element simulation, 100 % in simulation and 30 % ex vivo (Karstensen); simulators proposed for training (Sec. 3)",
   "sim2real": "mention (the simulation-to-ex-vivo drop named a domain-transfer problem)",
   "pages": "14 (34(3):239-252)",
   "n_refs": 79,
   "citations": 9,
   "read_level": "full (lit/txt + PDF, X1 2026-11-08); non-systematic mini-review, no search window stated; CC BY 4.0"
  },
  {
   "schema_version": 1,
   "key": "roshanfar2025_advanced",
   "year": 2025,
   "venue": "Micromachines",
   "title": "Advanced Robotics for the Next-Generation of Cardiac Interventions",
   "doi": "10.3390/mi16040363",
   "n_robots": "N.R. (narrative, per-system)",
   "robot_pictures": "yes for FDA-approved: Fig. 1 photos (CorPath GRX etc.); Fig. 2 autonomy classes with system images",
   "taxonomy_axes": "autonomy classes, shape sensing, haptics, tracking, soft robotics",
   "commercial": "yes",
   "academic": "yes",
   "actuated_tip": "yes",
   "magnetic": "partial",
   "simulation": "minor",
   "sim2real": "no",
   "pages": "N.R. (article 363)",
   "n_refs": 89,
   "citations": 8,
   "read_level": "full (JATS XML)"
  },
  {
   "schema_version": 1,
   "key": "sun2025_autonomous",
   "year": 2025,
   "venue": "iScience",
   "title": "Advancements and challenges in autonomous endovascular interventional robotics: A comprehensive review",
   "doi": "10.1016/j.isci.2025.114024",
   "n_robots": "N.R. (mechanism families Fig. 14-15; Table 2 ~20 control studies)",
   "robot_pictures": "partial: Fig. 14 mechanism schematics, Fig. 15 robot mechanisms",
   "taxonomy_axes": "autonomy grading (Table 1), sensing, control, execution; platform mechanisms",
   "commercial": "yes",
   "academic": "yes",
   "actuated_tip": "yes",
   "magnetic": "yes (83 hits)",
   "simulation": "yes (56 hits)",
   "sim2real": "reference list only (one sim-to-real title cited); no section",
   "pages": 37,
   "n_refs": 261,
   "citations": 0,
   "read_level": "full"
  },
  {
   "schema_version": 1,
   "key": "chen2026_teleoperation",
   "year": 2026,
   "venue": "IEEE T-MRB",
   "title": "Remote Teleoperation of Endovascular Intervention Robots: A Systematic Review",
   "doi": "10.1109/TMRB.2026.3681030",
   "n_robots": "16 studies; 7 platforms compared in Fig. 3",
   "robot_pictures": "partial: Fig. 3 comparative figure of seven platforms (interface columns)",
   "taxonomy_axes": "platforms, telecommunication framework, clinical evaluation",
   "commercial": "yes",
   "academic": "yes",
   "actuated_tip": "no",
   "magnetic": "14 hits",
   "simulation": "10 hits (latency tests)",
   "sim2real": "no",
   "pages": 15,
   "n_refs": 100,
   "citations": 0,
   "read_level": "full (V_ extract + txt)"
  },
  {
   "schema_version": 1,
   "key": "gunkan2025_foreseeable",
   "year": 2026,
   "venue": "Interv. Neuroradiol.",
   "title": "The foreseeable potential of robotics in neurointervention: Current robotic systems and applications",
   "doi": "10.1177/15910199251318405",
   "n_robots": "unknown (full text not read)",
   "robot_pictures": "unknown (full text not read)",
   "taxonomy_axes": "Letter (Europe PMC publication type), no abstract",
   "commercial": "unknown (full text not read)",
   "academic": "unknown (full text not read)",
   "actuated_tip": "unknown (full text not read)",
   "magnetic": "unknown (full text not read)",
   "simulation": "unknown (full text not read)",
   "sim2real": "unknown (full text not read)",
   "pages": "4 (32(4):2043-2046; online 2025)",
   "n_refs": "8 (Crossref)",
   "citations": "0 (COCI, R4A 2026-11-07)",
   "read_level": "title (Europe PMC lists a Letter, PMID 39905770)"
  },
  {
   "schema_version": 1,
   "key": "ji2026_soft",
   "year": 2026,
   "venue": "Nat. Rev. Cardiol.",
   "title": "Soft robotic devices for cardiovascular medicine",
   "doi": "10.1038/s41569-026-01287-7",
   "n_robots": "N.R. (no table; endovascular continuum instruments cited by reference; named commercial: Sensei, Amigo, Genesis RMN and GenesisX)",
   "robot_pictures": "none (Figs. 1-7 are schematics; Fig. 4 generic cartoons of cable, magnetic and fluidic tips)",
   "taxonomy_axes": "soft robotic simulators, interventional instruments (percutaneous, endovascular continuum, untethered), implants; actuation cable, fluidic, magnetic, SMA, dielectric elastomer (Box 1); variable stiffness; six-stage translation pathway (Fig. 7)",
   "commercial": "mention (Sensei, Amigo, Genesis RMN, GenesisX)",
   "academic": "no",
   "actuated_tip": "yes (cable, magnetic, fluidic continuum instruments)",
   "magnetic": "mention (Genesis RMN in clinical use; magnetic tips)",
   "simulation": "physical heart simulators only; no computational simulation of devices",
   "sim2real": "no",
   "pages": "19 (23(11):769-787)",
   "n_refs": 172,
   "citations": "0 (COCI, R4A 2026-11-07)",
   "read_level": "full (lit/txt + PDF, X1 2026-11-08)"
  },
  {
   "schema_version": 1,
   "key": "pantano2026_force",
   "year": 2026,
   "venue": "IEEE T-MRB",
   "title": "Force Measurement in Robot-Assisted Endovascular Procedures: A Systematic Review",
   "doi": "10.1109/TMRB.2026.3680997",
   "n_robots": "176 publications (force classes, not robots)",
   "robot_pictures": "partial: Fig. 1 Artis suite photo; Fig. 6-9, 11 test benches and sensors",
   "taxonomy_axes": "force taxonomy (8 classes) x sensor x experiment (in silico / in vitro / ex vivo / in vivo)",
   "commercial": "n/a",
   "academic": "n/a",
   "actuated_tip": "no",
   "magnetic": "no",
   "simulation": "in-silico tier of Table II",
   "sim2real": "no",
   "pages": 18,
   "n_refs": 203,
   "citations": 0,
   "read_level": "full (V_ extract)"
  },
  {
   "schema_version": 1,
   "key": "riosgarcia2026_thrombectomy",
   "year": 2026,
   "venue": "J. Robot. Surg.",
   "title": "Robot-Assisted Mechanical Thrombectomy for Neurointerventional Surgery: An Exploratory Scoping Review",
   "doi": "10.1007/s11701-026-03535-x",
   "n_robots": "14 studies",
   "robot_pictures": "N.R.",
   "taxonomy_axes": "scoping, clinical outcomes",
   "commercial": "yes",
   "academic": "no",
   "actuated_tip": "N.R.",
   "magnetic": "N.R.",
   "simulation": "N.R.",
   "sim2real": "no",
   "pages": "N.R.",
   "n_refs": 76,
   "citations": 0,
   "read_level": "structure"
  },
  {
   "schema_version": 1,
   "key": "yang2026_toward",
   "year": 2026,
   "venue": "Sci. Adv.",
   "title": "Toward autonomous robotic-assisted and microrobotic surgery",
   "doi": "10.1126/sciadv.aec4197",
   "n_robots": "N.R. (several anatomies; Fig. 1 endovascular)",
   "robot_pictures": "partial (4 composite figures)",
   "taxonomy_axes": "roadmap: autonomy across endovascular, endoluminal, ophthalmic, micro",
   "commercial": "mention",
   "academic": "mention",
   "actuated_tip": "mention",
   "magnetic": "28 hits",
   "simulation": "1 hit",
   "sim2real": "no",
   "pages": "N.R.",
   "n_refs": 206,
   "citations": 0,
   "read_level": "structure (JATS XML)"
  },
  {
   "schema_version": 1,
   "key": "yao2026_embodied",
   "year": 2026,
   "venue": "IEEE Rev. Biomed. Eng.",
   "title": "Advancing Embodied Intelligence in Robotic-Assisted Endovascular Procedures: A Systematic Review of AI Solutions",
   "doi": "10.1109/RBME.2025.3641383",
   "n_robots": "112 studies (AI methods, not robots)",
   "robot_pictures": "no (Fig. 1 four-panel concept)",
   "taxonomy_axes": "perception x learning-based control; Fig. 6 roadmap in silico > phantom > in vivo > clinical",
   "commercial": "mention",
   "academic": "mention",
   "actuated_tip": "no",
   "magnetic": "no",
   "simulation": "yes (validation tier)",
   "sim2real": "roadmap level only",
   "pages": 19,
   "n_refs": 134,
   "citations": 2,
   "read_level": "full (V_ extract)"
  }
 ]
}