Catheter Robot Atlas

Academic bedside robots · western_thakur2009

RCNS

Remote Catheter Navigation System (RCNS / MR-RCNS)
Western University and Robarts Research Institute (Drangova) · 2009–2016
RCNS: main picture1 / 5
Not cleared for distribution. tavallaei2016_mri3dof Fig. 2, upper half (3-DOF MR-compatible slave: handle manipulator + catheter manipulator; embedded 969x666). Licence: publisher copyright (Springer; (c) CARS 2015). Picture grade B.
Family
Academic bedside robots (academic)
Devices
6-7 F ablation catheters (input catheter as leader, patient catheter as follower)
Degrees of freedom
2 (axial, radial) in 2009 and 2013; 3 in 2016
Push
Friction rollers
Twist
Rotating drive unit
Tested up to
Animal
Sim-to-real
None found — No simulation-trained controller found for this robot.

Testing

Highest level
Animal
What was tested
2009: bench plus 8 operators navigating a carotid model; 2013: bench and in-scanner tests; porcine in-vivo and ex-vivo tests reported in the Western thesis (ir.lib.uwo.ca/etd/3024), web summary only, animal count not read
Key numbers
2009: within 1 mm and 1 deg, latency under 300 ms; 2013: delay 41+-21 ms, 2+-2 deg radial, 1.0+-0.8 mm over 100 mm axial; 2016: axial error < 1 mm over 30 mm; axial grip 4 N, radial grip 18 mN.m

Mechanism

Push (translation)
friction-roller (urethane drive wheel(s) with spring-loaded idler rollers; two chained active rollers from 2013)
Twist (rotation)
catheter in a slip-ring gantry rotated by a servo (2013: ultrasonic motors); chain drive
Device range
adjustable platform for different catheter gauges; 6-7 F used
Target anatomy
cardiac / EP catheterisation; carotid model; ablation lesions (porcine, thesis)

Sensing and interface

Force sensing
none
Leader and haptics
none; leader is a real input catheter read by optical encoders
Imaging
fluoroscopy (2009); MRI-compatible (2013): worst-case SNR drop 2.5%, slave 60 cm from isocentre; 2016 SNR drop < 3%, no artifacts
Sterility
N.R.

Size

Footprint (mm)
N.R.
Mass (kg)
N.R.

Simulation

Simulation model
none found
Sim-trained controller
none found

Versions

Lineage
2009 TBME (Thakur, fluoroscopy); 2013 TBME (Tavallaei, MR-compatible, ultrasonic motors); 2016 IJCARS (3 DOF, plunger added)

Sources

  1. Design and Performance Evaluation of a Remote Catheter Navigation System · IEEE Transactions on Biomedical Engineering, 2009 · doi:10.1109/TBME.2009.2017203 [thakur2009_remote]
  2. A Magnetic-Resonance-Imaging-Compatible Remote Catheter Navigation System · IEEE Transactions on Biomedical Engineering, 2013 · doi:10.1109/TBME.2012.2229709 [tavallaei2013_mri]
  3. Magnetic resonance imaging compatible remote catheter navigation system with 3 degrees of freedom · International Journal of Computer Assisted Radiology and Surgery, 2016 · doi:10.1007/s11548-015-1337-4 [tavallaei2016_mri3dof]

Notes

Notes
Row id uses 2009 first author; the same lab filed patents and founded Vital Biomedical Technologies (web, unverified).

This record

Read level
full — full (2009, 2013); abstract/web (2016, thesis)
Picture
tavallaei2016_mri3dof Fig. 2, upper half (3-DOF MR-compatible slave: handle manipulator + catheter manipulator; embedded 969x666) ↗ — licence: publisher copyright (Springer; (c) CARS 2015); grade B
Picture changes
native extract; cropped to the slave half; 4 text labels and 2 arrows erased with LaMa on the plain blue backdrop (one arrow lay on the catheter manipulator's black support rod; checked at 4x zoom); not upscaled
Found by
academic: Search of academic bedside robots.
Data
JSON · YAML: records/robots/western_thakur2009.yaml
Correction
Suggest a correction [repository not created yet]