 "schema_version": 1,
 "id": "western_thakur2009",
 "name": "RCNS",
 "full_name": "Remote Catheter Navigation System (RCNS / MR-RCNS)",
 "group": "Western University and Robarts Research Institute (Drangova)",
 "group_short": "Western U.",
 "family": "academic",
 "category": "academic",
 "first_year": 2009,
 "latest_year": 2016,
 "versions": "2009 TBME (Thakur, fluoroscopy); 2013 TBME (Tavallaei, MR-compatible, ultrasonic motors); 2016 IJCARS (3 DOF, plunger added)",
 "target_anatomy": "cardiac / EP catheterisation; carotid model; ablation lesions (porcine, thesis)",
 "devices": [
  "catheter"
 ],
 "devices_driven": "6-7 F ablation catheters (input catheter as leader, patient catheter as follower)",
 "n_dof": 2,
 "n_dof_detail": "2 (axial, radial) in 2009 and 2013; 3 in 2016",
 "translation_mechanism": "friction-roller",
 "translation_detail": "friction-roller (urethane drive wheel(s) with spring-loaded idler rollers; two chained active rollers from 2013)",
 "rotation_mechanism": "rotating-drive-unit",
 "rotation_detail": "catheter in a slip-ring gantry rotated by a servo (2013: ultrasonic motors); chain drive",
 "device_range": "adjustable platform for different catheter gauges; 6-7 F used",
 "footprint_mm": "N.R.",
 "mass_kg": "N.R.",
 "force_sensing": "none",
 "haptics_leader": "none; leader is a real input catheter read by optical encoders",
 "imaging_compat": "fluoroscopy (2009); MRI-compatible (2013): worst-case SNR drop 2.5%, slave 60 cm from isocentre; 2016 SNR drop < 3%, no artifacts",
 "sterility": "N.R.",
 "highest_validation": "animal",
 "validation_detail": "2009: bench plus 8 operators navigating a carotid model; 2013: bench and in-scanner tests; porcine in-vivo and ex-vivo tests reported in the Western thesis (ir.lib.uwo.ca/etd/3024), web summary only, animal count not read",
 "key_numbers": "2009: within 1 mm and 1 deg, latency under 300 ms; 2013: delay 41+-21 ms, 2+-2 deg radial, 1.0+-0.8 mm over 100 mm axial; 2016: axial error < 1 mm over 30 mm; axial grip 4 N, radial grip 18 mN.m",
 "sim_model": "none found",
 "has_sim_model": false,
 "sim2real": "none-found",
 "sim2real_detail": "none found",
 "picture": {
  "status": "not-cleared",
  "grade": "B",
  "kind": "photo",
  "source": "tavallaei2016_mri3dof Fig. 2, upper half (3-DOF MR-compatible slave: handle manipulator + catheter manipulator; embedded 969x666)",
  "source_url": "https://doi.org/10.1007/s11548-015-1337-4",
  "licence": "publisher copyright (Springer; (c) CARS 2015)",
  "credit": "Tavallaei et al., International Journal of Computer Assisted Radiology and Surgery (2016), Fig. 2. publisher copyright (Springer; (c) CARS 2015).",
  "edits": "native extract; cropped to the slave half; 4 text labels and 2 arrows erased with LaMa on the plain blue backdrop (one arrow lay on the catheter manipulator's black support rod; checked at 4x zoom); not upscaled",
  "file": null
 },
 "pictures": [
  {
   "id": "western_thakur2009_01",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "in-use",
   "caption": "MR-compatible catheter manipulator on the patient table at the MRI bore",
   "source_key": "tavallaei2016_mri3dof",
   "source": "Tavallaei et al., International Journal of Computer Assisted Radiology and Surgery (2016), Fig. 1 (photo part), p. 2",
   "source_url": "https://doi.org/10.1007/s11548-015-1337-4",
   "where": "Fig. 1 (photo part), p. 2",
   "licence": "publisher copyright (Springer; (c) CARS 2015)"
  },
  {
   "id": "western_thakur2009_02",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "leader",
   "caption": "Master user interface: catheter sensor and plunger sensor for the input catheter",
   "source_key": "tavallaei2016_mri3dof",
   "source": "Tavallaei et al., International Journal of Computer Assisted Radiology and Surgery (2016), Fig. 2, lower half, p. 2",
   "source_url": "https://doi.org/10.1007/s11548-015-1337-4",
   "where": "Fig. 2, lower half, p. 2",
   "licence": "publisher copyright (Springer; (c) CARS 2015)"
  },
  {
   "id": "western_thakur2009_03",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "photo",
   "caption": "2009 fluoroscopy version: catheter sensor, gantry catheter manipulator and phantom",
   "source_key": "thakur2009_remote",
   "source": "Thakur et al., IEEE Transactions on Biomedical Engineering (2009), Fig. 1, p. 2",
   "source_url": "https://doi.org/10.1109/TBME.2009.2017203",
   "where": "Fig. 1, p. 2",
   "licence": "publisher copyright (IEEE)"
  },
  {
   "id": "western_thakur2009_04",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "photo",
   "caption": "2013 MR-compatible version: master catheter sensor beside the ultrasonic-motor slave",
   "source_key": "tavallaei2013_mri",
   "source": "Tavallaei et al., IEEE Transactions on Biomedical Engineering (2013), Fig. 2, p. 2",
   "source_url": "https://doi.org/10.1109/TBME.2012.2229709",
   "where": "Fig. 2, p. 2",
   "licence": "publisher copyright (IEEE)"
  }
 ],
 "sources": [
  {
   "key": "thakur2009_remote",
   "doi": "10.1109/TBME.2009.2017203",
   "url": null,
   "title": "Design and Performance Evaluation of a Remote Catheter Navigation System",
   "year": 2009,
   "venue": "IEEE Transactions on Biomedical Engineering"
  },
  {
   "key": "tavallaei2013_mri",
   "doi": "10.1109/TBME.2012.2229709",
   "url": null,
   "title": "A Magnetic-Resonance-Imaging-Compatible Remote Catheter Navigation System",
   "year": 2013,
   "venue": "IEEE Transactions on Biomedical Engineering"
  },
  {
   "key": "tavallaei2016_mri3dof",
   "doi": "10.1007/s11548-015-1337-4",
   "url": null,
   "title": "Magnetic resonance imaging compatible remote catheter navigation system with 3 degrees of freedom",
   "year": 2016,
   "venue": "International Journal of Computer Assisted Radiology and Surgery"
  }
 ],
 "read_level": "full",
 "read_level_detail": "full (2009, 2013); abstract/web (2016, thesis)",
 "notes": "Row id uses 2009 first author; the same lab filed patents and founded Vital Biomedical Technologies (web, unverified).",
 "maintainers_own": false,
 "found_by": "academic"
}