Catheter Robot Atlas

Academic bedside robots · southeast_jin2024

MR-fluid platform

Southeast University / Kagawa MR-fluid haptic robotic platform with force sensing and guidewire-catheter collaborative operation
Southeast University, State Key Laboratory of Digital Medical Engineering (Aiguo Song; Xiaoliang Jin) with Kagawa University (Shuxiang Guo); Zhuhai Hanglok Medical Technology co-author on the 2025 follow-up · 2023–2024
MR-fluid platform: main picture1 / 7
Not cleared for distribution. jin2024_novel Fig. 6 (follower manipulator with CMU and GMU), T-IM 2024, doi:10.1109/TIM.2023.3338682. Licence: publisher copyright. Picture grade C.
Family
Academic bedside robots (academic)
Devices
guidewire and catheter (guidewire unit GMU, catheter unit CMU)
Degrees of freedom
N.R.
Push
Linear stage
Twist
Rotating clamp
Tested up to
Phantom
Sim-to-real
None found — No simulation-trained controller found for this robot.

Testing

Highest level
Phantom
What was tested
Vessel model and EVE endovascular evaluator; sample counts N.R. in the sections read
Key numbers
Load cell +/-5 N; stepper 0.36 deg resolution; haptic force 0.4-2.1 N for 0-0.6 A (plot reading)

Mechanism

Push (translation)
linear-stage+clamp
Twist (rotation)
Synchronous-belt rotation of the grasper (pulley diameter 46.3 mm; belt also used for linear motion)
Device range
N.R.
Target anatomy
vessel model; endovascular evaluator (EVE) model at 120/80 mmHg

Sensing and interface

Force sensing
Total proximal force by TEAC TU-UJ5N load cell (-5 to 5 N) on a lead screw behind the grasper (spring-loaded slider moves slightly under load); torque by torque sensor during rotation; load cell reads positive for guidewire insertion
Leader and haptics
MR-fluid haptic leader: two coils (30 mm inner, 120 mm outer diameter, 1200 turns); haptic force rises with current over 0-0.6 A (about 0.4 to 2.1 N, read from the Fig. 5 plot)
Imaging
N.R.
Sterility
N.R.; grasper contact blocks are rubber-faced and opened by hollow steppers

Size

Footprint (mm)
rail with ruler in Fig. 6 photo; size N.R.
Mass (kg)
N.R.

Simulation

Simulation model
none found
Sim-trained controller
none found

Versions

Lineage
jin2024_novel (T-IM 2024, received Mar 2023) -> jin2025_natural (T-HMS 2025: leader device with haptic feedback; abstract not read)

Sources

  1. A Novel Robotic Platform for Endovascular Surgery: Human–Robot Interaction Studies · IEEE Transactions on Instrumentation and Measurement, 2024 · doi:10.1109/tim.2023.3338682 [jin2024_novel]

Notes

Notes
Same Kagawa lineage as kagawa_mrf_guo2019 but with a load cell mounted on the grasper slide for proximal force. | 2026-10-13 coordinator: jin2025_natural moved to hanglok_wang2024: its follower is the Hanglok MULLER unit (W4, P2) | 2026-10-13 Q2: latest_year 2025 -> 2024 after jin2025_natural moved to hanglok_wang2024

This record

Read level
partial — partial (jin2024 text); abstract (jin2025)
Picture
jin2024_novel Fig. 6 (follower manipulator with CMU and GMU), T-IM 2024, doi:10.1109/TIM.2023.3338682 ↗ — licence: publisher copyright; grade C
Picture changes
native extract (688x380, the largest copy in the PDF); red dashed unit boxes, 4 labels and 4 arrows removed (OpenCV Telea, colour and darkness masks on the wall and rail); 5 px frame cropped; not upscaled.
Found by
academic: Search of academic bedside robots.
Data
JSON · YAML: records/robots/southeast_jin2024.yaml
Correction
Suggest a correction [repository not created yet]