 "schema_version": 1,
 "id": "southeast_jin2024",
 "name": "MR-fluid platform",
 "full_name": "Southeast University / Kagawa MR-fluid haptic robotic platform with force sensing and guidewire-catheter collaborative operation",
 "group": "Southeast University, State Key Laboratory of Digital Medical Engineering (Aiguo Song; Xiaoliang Jin) with Kagawa University (Shuxiang Guo); Zhuhai Hanglok Medical Technology co-author on the 2025 follow-up",
 "group_short": "Southeast U.",
 "family": "academic",
 "category": "academic",
 "first_year": 2023,
 "latest_year": 2024,
 "versions": "jin2024_novel (T-IM 2024, received Mar 2023) -> jin2025_natural (T-HMS 2025: leader device with haptic feedback; abstract not read)",
 "target_anatomy": "vessel model; endovascular evaluator (EVE) model at 120/80 mmHg",
 "devices": [
  "guidewire",
  "catheter"
 ],
 "devices_driven": "guidewire and catheter (guidewire unit GMU, catheter unit CMU)",
 "n_dof": null,
 "n_dof_detail": "N.R.",
 "translation_mechanism": "linear-stage+clamp",
 "translation_detail": "linear-stage+clamp",
 "rotation_mechanism": "rotating-clamp",
 "rotation_detail": "Synchronous-belt rotation of the grasper (pulley diameter 46.3 mm; belt also used for linear motion)",
 "device_range": "N.R.",
 "footprint_mm": "rail with ruler in Fig. 6 photo; size N.R.",
 "mass_kg": "N.R.",
 "force_sensing": "Total proximal force by TEAC TU-UJ5N load cell (-5 to 5 N) on a lead screw behind the grasper (spring-loaded slider moves slightly under load); torque by torque sensor during rotation; load cell reads positive for guidewire insertion",
 "haptics_leader": "MR-fluid haptic leader: two coils (30 mm inner, 120 mm outer diameter, 1200 turns); haptic force rises with current over 0-0.6 A (about 0.4 to 2.1 N, read from the Fig. 5 plot)",
 "imaging_compat": "N.R.",
 "sterility": "N.R.; grasper contact blocks are rubber-faced and opened by hollow steppers",
 "highest_validation": "phantom",
 "validation_detail": "Vessel model and EVE endovascular evaluator; sample counts N.R. in the sections read",
 "key_numbers": "Load cell +/-5 N; stepper 0.36 deg resolution; haptic force 0.4-2.1 N for 0-0.6 A (plot reading)",
 "sim_model": "none found",
 "has_sim_model": false,
 "sim2real": "none-found",
 "sim2real_detail": "none found",
 "picture": {
  "status": "not-cleared",
  "grade": "C",
  "kind": "photo",
  "source": "jin2024_novel Fig. 6 (follower manipulator with CMU and GMU), T-IM 2024, doi:10.1109/TIM.2023.3338682",
  "source_url": "https://doi.org/10.1109/TIM.2023.3338682",
  "licence": "publisher copyright",
  "credit": "Jin et al., IEEE Transactions on Instrumentation and Measurement (2024), Fig. 6. publisher copyright.",
  "edits": "native extract (688x380, the largest copy in the PDF); red dashed unit boxes, 4 labels and 4 arrows removed (OpenCV Telea, colour and darkness masks on the wall and rail); 5 px frame cropped; not upscaled.",
  "file": null
 },
 "pictures": [
  {
   "id": "southeast_jin2024_01",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "in-use",
   "caption": "Follower manipulator delivering devices into the EVE model under a camera",
   "source_key": "jin2024_novel",
   "source": "Jin et al., IEEE Transactions on Instrumentation and Measurement (2024), Fig. 13, p. 6",
   "source_url": "https://doi.org/10.1109/tim.2023.3338682",
   "where": "Fig. 13, p. 6",
   "licence": "publisher copyright"
  },
  {
   "id": "southeast_jin2024_02",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "leader",
   "caption": "MR-fluid leader manipulator with catheter and guidewire control units",
   "source_key": "jin2024_novel",
   "source": "Jin et al., IEEE Transactions on Instrumentation and Measurement (2024), Fig. 3, p. 3",
   "source_url": "https://doi.org/10.1109/tim.2023.3338682",
   "where": "Fig. 3, p. 3",
   "licence": "publisher copyright"
  },
  {
   "id": "southeast_jin2024_03",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "leader",
   "caption": "Linkage leader device coupled to an F/T sensor for testing",
   "source_key": "jin2025_natural",
   "source": "Jin et al., IEEE Transactions on Human-Machine Systems (2025), Fig. 7, p. 5",
   "source_url": "https://doi.org/10.1109/thms.2025.3591542",
   "where": "Fig. 7, p. 5",
   "licence": "publisher copyright"
  },
  {
   "id": "southeast_jin2024_04",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "setup",
   "caption": "Leader device next to the follower manipulator and joystick",
   "source_key": "jin2025_natural",
   "source": "Jin et al., IEEE Transactions on Human-Machine Systems (2025), Fig. 12, p. 7",
   "source_url": "https://doi.org/10.1109/thms.2025.3591542",
   "where": "Fig. 12, p. 7",
   "licence": "publisher copyright"
  },
  {
   "id": "southeast_jin2024_05",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "close-up",
   "caption": "Grasper device with two sliding blocks driven by stepping motors",
   "source_key": "jin2024_novel",
   "source": "Jin et al., IEEE Transactions on Instrumentation and Measurement (2024), Fig. 7(a), p. 4",
   "source_url": "https://doi.org/10.1109/tim.2023.3338682",
   "where": "Fig. 7(a), p. 4",
   "licence": "publisher copyright"
  },
  {
   "id": "southeast_jin2024_06",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "render",
   "caption": "CAD of the leader device: linkage, encoders and DC motors",
   "source_key": "jin2025_natural",
   "source": "Jin et al., IEEE Transactions on Human-Machine Systems (2025), Fig. 3(a), p. 3",
   "source_url": "https://doi.org/10.1109/thms.2025.3591542",
   "where": "Fig. 3(a), p. 3",
   "licence": "publisher copyright"
  }
 ],
 "sources": [
  {
   "key": "jin2024_novel",
   "doi": "10.1109/tim.2023.3338682",
   "url": null,
   "title": "A Novel Robotic Platform for Endovascular Surgery: Human–Robot Interaction Studies",
   "year": 2024,
   "venue": "IEEE Transactions on Instrumentation and Measurement"
  }
 ],
 "read_level": "partial",
 "read_level_detail": "partial (jin2024 text); abstract (jin2025)",
 "notes": "Same Kagawa lineage as kagawa_mrf_guo2019 but with a load cell mounted on the grasper slide for proximal force. | 2026-10-13 coordinator: jin2025_natural moved to hanglok_wang2024: its follower is the Hanglok MULLER unit (W4, P2) | 2026-10-13 Q2: latest_year 2025 -> 2024 after jin2025_natural moved to hanglok_wang2024",
 "maintainers_own": false,
 "found_by": "academic"
}