BUPT guidewire robot

BUPT guidewire feeding robot (friction-wheel push-pull, gear rotation) used for deep-RL guidewire feeding on a vessel phantom
Beijing University of Posts and Telecommunications, School of Automation (Deai Yang, Jingzhou Song, Yuhang Hu) (yang2022_guidewire p. 1287; Crossref affiliations) · 2022
BUPT guidewire robot: main picture1 / 2
Not cleared for distribution. yang2022_guidewire Fig. 1 (experimental platform), right part, p. 4. Licence: publisher copyright (IEEE). Picture grade C.
Family
Academic bedside robots (academic)
Devices
one guidewire (type N.R.)
Degrees of freedom
2: push-pull and rotation, decoupled (Sec. IV-A)
Push
Friction rollers
Twist
Other
Tested up to
Phantom
Sim-to-real
None found — No simulation-trained controller found for this robot.

Testing

Highest level
Phantom
What was tested
phantom: two training-and-test experiments on the physical phantom, (1) push-pull only, 500 episodes of <= 150 steps in 2.5 h, converged after about 260 episodes; (2) push-pull plus rotation, 500 episodes in 4.2 h, converged after about 300; test runs reached the target within the 40-pixel (about 5 mm) termination criterion (Sec. IV-C, Figs. 8-13). Number of test runs N.R.
Key numbers
push-pull accuracy 1 mm, rotation accuracy 5 deg (Sec. IV-A); action limits +/-20 mm, +/-90 deg (Sec. III-A); feeding error < 5 mm, tip detection >= 92.9 % (Abstract); YOLOv5s 23 ms per image (Sec. IV-B)

Mechanism

Push (translation)
friction-roller: 'It moves the guidewire forward or backward via a pair of friction wheels clamping it' (Sec. IV-A)
Twist (rotation)
'The rotation of the guidewire around the central axis is achieved by a pair of rotating gears' (Sec. IV-A)
Device range
N.R.
Target anatomy
abdominal-aorta target in a vessel phantom with pumped water at a controlled temperature (Sec. IV-A, IV-C, Figs. 1-2, 7); detection images from the phantom's femoral artery and aortic arch (Sec. IV-B)

Sensing and interface

Force sensing
none (force from the motor current proposed as future work, Sec. V)
Leader and haptics
none: an autonomous SAC agent on a server sends (push-pull, rotation) actions (Sec. IV-A, Fig. 2)
Imaging
camera above the transparent phantom; the YOLOv5s tip detector was also run on angiographic images (Fig. 5); fluoroscopy with the robot N.R.
Sterility
N.R.

Size

Footprint (mm)
N.R.
Mass (kg)
N.R.

Simulation

Simulation model
none found
Sim-trained controller
none found: the policy is trained on the physical phantom without a simulator ('To avoid the error caused by the virtual simulation environment, we built an interventional surgery experimental platform based on vessel phantom', Sec. IV-A)

Versions

Lineage
single paper (yang2022_guidewire, ICMA 2022); the robot is described only in its Sec. IV-A

Sources

  1. Guidewire feeding method based on deep reinforcement learning for vascular intervention robot · 2022 IEEE International Conference on Mechatronics and Automation (ICMA), 2022 · doi:10.1109/icma54519.2022.9856351 [yang2022_guidewire]
  2. Robotically steerable guidewires—Current trends and future directions · Science Robotics, 2025 · doi:10.1126/scirobotics.adt7461 [konda2025_robotically]

Notes

Notes
N3 2026-11-08, from review_comparison Sec. 1.3 (Konda 2025 control row 37, ref. 129, one of the 'learning-only controllers'). The controller ran on this physical robot, so the robot itself is catalogued. No other paper describing the robot was found. Picture is 229 px wide and carries the tip of a red pointer: the robot is about a third of the 727 px setup photo.

This record

Read level
full
Picture
yang2022_guidewire Fig. 1 (experimental platform), right part, p. 4 ↗ — licence: publisher copyright (IEEE); grade C
Picture changes
native embedded raster (727 x 456) cropped to the robot (box 498,195,727,378); tip of the red pointer of the 'guidewire feeding robot' label remains at the lower left; not upscaled
Found by
gap: Gap searches for robots the other searches missed.
Data
JSON · YAML: records/robots/bupt_yang2022.yaml
Correction
Suggest a correction [repository not created yet]