Catheter Robot Atlas

Actuated-tip devices · balloongw_barre2025

Balloon guidewire

Tendon-driven steerable guidewire with retractable distal balloon (+ handheld actuation)
Desai, Georgia Tech Robomed Lab · 2025–2026
Balloon guidewire: main picture1 / 7
Not cleared for distribution. barre2025_towards Fig. 3(a) (actuation system, top view). Licence: publisher copyright (IEEE). Picture grade B.
Family
Actuated-tip devices (actuated-device)
Devices
own notched-nitinol tendon guidewire (0.48 mm OD nitinol tube, 20 mm UAN bending segment, 76 um nitinol tendon in 2026 paper); balloon wire uses 0.15 mm nitinol tendon
Degrees of freedom
bend, feed, roll (handheld); plus balloon inflation (2025)
Push
Tip-actuated
Twist
Rotating drive unit
Tested up to
Phantom
Sim-to-real
None found — No simulation-trained controller found for this robot.

Testing

Highest level
Phantom
What was tested
2025: phantom vessel under pulsatile flow, traversal, balloon inflation, flow arrest (one demonstration); 2026: one navigation of an abdominal aorta phantom, wire buckled between phantom entry and device (abstract-level counts N.R.)
Key numbers
balloon radii inflated 0.75-2.50 mm in 0.25 mm steps; 1.22 mm OD balloon on guidewire; Abaqus model of balloon inflation; pressure-channel test: position change 0.038 mm and curvature change 0.2 % (barre2025 Sec. V, context only partly read)

Mechanism

Push (translation)
tendon/tip-actuation
Twist (rotation)
motorised spool roll (handheld, 2026)
Device range
up to 1.5 m of wire spooled (2026)
Target anatomy
endovascular, phantom vessel 3 mm ID with three branches

Sensing and interface

Force sensing
N.R.
Leader and haptics
no (joystick, momentary switch)
Imaging
C-arm in phantom test; MR compatibility N.R.
Sterility
N.R.

Size

Footprint (mm)
handheld housing 341.7 x 110.4 (Fig. 1e)
Mass (kg)
0.836 (handheld device)

Simulation

Simulation model
Abaqus FE model of balloon inflation plus analytical curvature model (barre2025 Sec. III-IV, partial read)
Sim-trained controller
none found

Versions

Lineage
2025 balloon guidewire (barre2025_towards); 2026 handheld actuation mechanism for tendon-driven guidewire, 0.836 kg, up to 1.5 m of wire, joystick feed/roll/bend (chavenet2026_handheld)

Sources

  1. Towards a Tendon-Driven Robotically Steerable Guidewire With a Retractable Distal Balloon · IEEE Robotics and Automation Letters, 2025 · doi:10.1109/lra.2025.3590303 [barre2025_towards]
  2. Development of a Handheld Actuation Mechanism for a Tendon-driven Robotically Steered Guidewire · link [chavenet2026_handheld]

Notes

Notes
Entry kept separate from COAST because the tube is a single notched outer tube, not three coaxial tubes.

This record

Read level
full — full text downloaded, read selectively (key numbers by grep); arXiv chavenet2026 read intro+methods
Picture
barre2025_towards Fig. 3(a) (actuation system, top view) ↗ — licence: publisher copyright (IEEE); grade B
Picture changes
native extract (2036 px); cropped at x=1345 to keep the orange zoom-box leader (which crosses the load cell) out; orange box edges beside the gauge erased (LaMa, 2 passes)
Found by
actuated-tip: Search of actuated-tip and magnetic devices.
Data
JSON · YAML: records/robots/balloongw_barre2025.yaml
Correction
Suggest a correction [repository not created yet]