 "schema_version": 1,
 "id": "balloongw_barre2025",
 "name": "Balloon guidewire",
 "full_name": "Tendon-driven steerable guidewire with retractable distal balloon (+ handheld actuation)",
 "group": "Desai, Georgia Tech Robomed Lab",
 "group_short": "Georgia Tech",
 "family": "tip",
 "category": "actuated-device",
 "first_year": 2025,
 "latest_year": 2026,
 "versions": "2025 balloon guidewire (barre2025_towards); 2026 handheld actuation mechanism for tendon-driven guidewire, 0.836 kg, up to 1.5 m of wire, joystick feed/roll/bend (chavenet2026_handheld)",
 "target_anatomy": "endovascular, phantom vessel 3 mm ID with three branches",
 "devices": [
  "guidewire",
  "therapeutic-device"
 ],
 "devices_driven": "own notched-nitinol tendon guidewire (0.48 mm OD nitinol tube, 20 mm UAN bending segment, 76 um nitinol tendon in 2026 paper); balloon wire uses 0.15 mm nitinol tendon",
 "n_dof": null,
 "n_dof_detail": "bend, feed, roll (handheld); plus balloon inflation (2025)",
 "translation_mechanism": "tendon/tip-actuation",
 "translation_detail": "tendon/tip-actuation",
 "rotation_mechanism": "rotating-drive-unit",
 "rotation_detail": "motorised spool roll (handheld, 2026)",
 "device_range": "up to 1.5 m of wire spooled (2026)",
 "footprint_mm": "handheld housing 341.7 x 110.4 (Fig. 1e)",
 "mass_kg": "0.836 (handheld device)",
 "force_sensing": "N.R.",
 "haptics_leader": "no (joystick, momentary switch)",
 "imaging_compat": "C-arm in phantom test; MR compatibility N.R.",
 "sterility": "N.R.",
 "highest_validation": "phantom",
 "validation_detail": "2025: phantom vessel under pulsatile flow, traversal, balloon inflation, flow arrest (one demonstration); 2026: one navigation of an abdominal aorta phantom, wire buckled between phantom entry and device (abstract-level counts N.R.)",
 "key_numbers": "balloon radii inflated 0.75-2.50 mm in 0.25 mm steps; 1.22 mm OD balloon on guidewire; Abaqus model of balloon inflation; pressure-channel test: position change 0.038 mm and curvature change 0.2 % (barre2025 Sec. V, context only partly read)",
 "sim_model": "Abaqus FE model of balloon inflation plus analytical curvature model (barre2025 Sec. III-IV, partial read)",
 "has_sim_model": true,
 "sim2real": "none-found",
 "sim2real_detail": "none found",
 "picture": {
  "status": "not-cleared",
  "grade": "B",
  "kind": "photo",
  "source": "barre2025_towards Fig. 3(a) (actuation system, top view)",
  "source_url": "https://doi.org/10.1109/lra.2025.3590303",
  "licence": "publisher copyright (IEEE)",
  "credit": "Barré et al., IEEE Robotics and Automation Letters (2025), Fig. 3(a). publisher copyright (IEEE).",
  "edits": "native extract (2036 px); cropped at x=1345 to keep the orange zoom-box leader (which crosses the load cell) out; orange box edges beside the gauge erased (LaMa, 2 passes)",
  "file": null
 },
 "pictures": [
  {
   "id": "balloongw_barre2025_01",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "in-use",
   "caption": "Actuation system driving the balloon guidewire into a pulsatile-flow phantom",
   "source_key": "barre2025_towards",
   "source": "Barré et al., IEEE Robotics and Automation Letters (2025), Fig. 10(a-c), p. 5",
   "source_url": "https://doi.org/10.1109/lra.2025.3590303",
   "where": "Fig. 10(a-c), p. 5",
   "licence": "publisher copyright"
  },
  {
   "id": "balloongw_barre2025_02",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "in-use",
   "caption": "Handheld actuation mechanism steering the guidewire in a vascular phantom",
   "source_key": "chavenet2026_handheld",
   "source": "Chavenet et al. (2026), Fig. 2(a), p. 2",
   "source_url": "https://arxiv.org/abs/2607.24629",
   "where": "Fig. 2(a), p. 2",
   "licence": "arXiv non-exclusive distribution licence 1.0"
  },
  {
   "id": "balloongw_barre2025_03",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "photo",
   "caption": "Handheld actuation mechanism prototype with thumb joystick, cover partly open",
   "source_key": "chavenet2026_handheld",
   "source": "Chavenet et al. (2026), Fig. 1(a), p. 1",
   "source_url": "https://arxiv.org/abs/2607.24629",
   "where": "Fig. 1(a), p. 1",
   "licence": "arXiv non-exclusive distribution licence 1.0"
  },
  {
   "id": "balloongw_barre2025_04",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "render",
   "caption": "Section rendering of the handheld mechanism: spool, roll gear, tendon motor",
   "source_key": "chavenet2026_handheld",
   "source": "Chavenet et al. (2026), Fig. 1(b), p. 1",
   "source_url": "https://arxiv.org/abs/2607.24629",
   "where": "Fig. 1(b), p. 1",
   "licence": "arXiv non-exclusive distribution licence 1.0"
  },
  {
   "id": "balloongw_barre2025_05",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "close-up",
   "caption": "Syringe pump module that inflates the distal balloon",
   "source_key": "barre2025_towards",
   "source": "Barré et al., IEEE Robotics and Automation Letters (2025), Fig. 3(b), p. 2",
   "source_url": "https://doi.org/10.1109/lra.2025.3590303",
   "where": "Fig. 3(b), p. 2",
   "licence": "publisher copyright"
  },
  {
   "id": "balloongw_barre2025_06",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "render",
   "caption": "Section and exploded views of the guidewire with retractable balloon",
   "source_key": "barre2025_towards",
   "source": "Barré et al., IEEE Robotics and Automation Letters (2025), Fig. 2, p. 2",
   "source_url": "https://doi.org/10.1109/lra.2025.3590303",
   "where": "Fig. 2, p. 2",
   "licence": "publisher copyright"
  }
 ],
 "sources": [
  {
   "key": "barre2025_towards",
   "doi": "10.1109/lra.2025.3590303",
   "url": null,
   "title": "Towards a Tendon-Driven Robotically Steerable Guidewire With a Retractable Distal Balloon",
   "year": 2025,
   "venue": "IEEE Robotics and Automation Letters"
  },
  {
   "key": "chavenet2026_handheld",
   "doi": null,
   "url": "https://arxiv.org/abs/2607.24629",
   "title": "Development of a Handheld Actuation Mechanism for a Tendon-driven Robotically Steered Guidewire",
   "year": 2026,
   "venue": null
  }
 ],
 "read_level": "full",
 "read_level_detail": "full text downloaded, read selectively (key numbers by grep); arXiv chavenet2026 read intro+methods",
 "notes": "Entry kept separate from COAST because the tube is a single notched outer tube, not three coaxial tubes.",
 "maintainers_own": false,