Catheter Robot Atlas

Magnetic navigation · armm_heunis2020

ARMM

ARMM (Advanced Robotics for Magnetic Manipulation)
Misra, Surgical Robotics Lab, University of Twente · 2019–2020
ARMM: main picture1 / 4
Not cleared for distribution. U-Today 2021-06-28 "Robot for surgeries inside blood vessels", photo by Hans Wolkers: https://www.utoday.nl/uploads/images/2021/week26/_Z723444.jpg (UR arm with electromagnet over the torso phantom, researcher operating). Licence: press image (U-Today / Hans Wolkers), terms not stated. Picture grade A.
Family
Magnetic navigation (magnetic-navigation)
Devices
commercial Sherpa NX Active 2 mm coronary guide catheter (500 mm) with five NdFeB magnets (2 mm x 2 mm) in the tip
Degrees of freedom
two UR manipulators (UR10 carries the electromagnetic coil, UR5 carries the ultrasound probe) plus a 1-axis catheter insertion device
Push
Magnetic
Twist
Field direction
Tested up to
Phantom
Sim-to-real
None found — No simulation-trained controller found for this robot.

Testing

Highest level
Phantom
What was tested
gelatin torso phantom with pulsating flow, 3D targets, PI control; target count N.R. in my read
Key numbers
coil at least 20 mT and over 0.6 mT/mm at 50-200 mm; mean tip error 2.09 +/- 0.49 mm; median time to target 32.6 s

Mechanism

Push (translation)
magnetic (steering); separate insertion device, servo-driven gear and bearing, 1.3-6.4 mm/s, takes 3-34 Fr
Twist (rotation)
coil pose, no shaft rotation
Device range
500 mm catheter
Target anatomy
iliac / aortic phantom from CT of a 62-year-old (gelatin torso phantom, pulsating flow)

Sensing and interface

Force sensing
none; tip tracked by ultrasound (30 Hz) and motion capture
Leader and haptics
no
Imaging
3D ultrasound feedback, optical motion capture; radiation-free
Sterility
N.R.

Size

Footprint (mm)
workspace sphere radius 783 mm (max 1300 mm); 9 m3 environment
Mass (kg)
N.R.

Simulation

Simulation model
none found (dipole-field actuation model; no simulator)
Sim-trained controller
none found

Versions

Lineage
single (RA-L 2020); coil optimisation in Sikorski 2019 (cited, not read); 2016: Twente (Misra) magnetically actuated catheter in closed loop on 2D ultrasound (Boskma, Scheggi, Misra 2016 BioRob) (Alekseeva 2025 Table 12 row 6) (alekseeva2025_design)

Sources

  1. The ARMM System - Autonomous Steering of Magnetically-Actuated Catheters: Towards Endovascular Applications · IEEE Robotics and Automation Letters, 2020 · doi:10.1109/lra.2020.2965077 [heunis2020_armm]
  2. The Design of Endovascular Robots for Cardiac Interventions: A Survey · Journal of Field Robotics, 2024 · doi:10.1002/rob.22480 [alekseeva2025_design]

Notes

Notes
Mobile electromagnet on a robot arm; not a clinical room install.

This record

Read level
full
Picture
U-Today 2021-06-28 "Robot for surgeries inside blood vessels", photo by Hans Wolkers: https://www.utoday.nl/uploads/images/2021/week26/_Z723444.jpg (UR arm with electromagnet over the torso phantom, researcher operating) ↗ — licence: press image (U-Today / Hans Wolkers), terms not stated; grade A
Picture changes
downscaled 50 % from 5315 px (no crop); not upscaled
Found by
actuated-tip: Search of actuated-tip and magnetic devices.
Data
JSON · YAML: records/robots/armm_heunis2020.yaml
Correction
Suggest a correction [repository not created yet]