 "schema_version": 1,
 "id": "ujn_cao2024",
 "name": "UJN catheter drive",
 "full_name": "University of Jinan compact continuous-delivery catheter drive with friction wheels in a disposable surgical box and a constant-force clamp",
 "group": "School of Mechanical Engineering, University of Jinan (Tianxiao Cao, Rongyu Ge [corresponding], Yi Zhang, Wenlong Wang) (cao2024_cathdrive, affiliation lines)",
 "group_short": "U. of Jinan",
 "family": "academic",
 "category": "academic",
 "first_year": 2024,
 "latest_year": 2024,
 "versions": "single version (cao2024_cathdrive, IDITR 2024); Alekseeva 2025 Table 10 lists a design by the same authors (W. Wang et al. 2024, clamping bracket block) as TRL2 concept, not catalogued",
 "target_anatomy": "N.R. (general vascular intervention; coronary, brain, liver and kidney lesions named in the introduction)",
 "devices": [
  "catheter"
 ],
 "devices_driven": "one catheter (Sec. II); tests with a catheter (Figs. 13-14)",
 "n_dof": 2,
 "n_dof_detail": "2 (axial feed, circumferential rotation) (Sec. II)",
 "translation_mechanism": "friction-roller",
 "translation_detail": "friction-roller: two active and two driven grooved friction wheels in a disposable box, the active ones driven through three gear shafts by one motor; the box couples to the power unit by a triangular-prism shaft (Sec. II-A1, II-B, Figs. 2, 4, 7)",
 "rotation_mechanism": "rotating-drive-unit",
 "rotation_detail": "gear pair rotates the whole axial-feed unit, the feed motor rides along, wires through a conductive slip ring (Sec. II-A2, Fig. 3)",
 "device_range": "N.R. (constant-force clamp adjustable by spring pre-compression, Sec. II-B, III)",
 "footprint_mm": "N.R.",
 "mass_kg": "N.R.",
 "force_sensing": "none (a sawtooth constant-force clamp caps the clamping force mechanically, Sec. II-B, III)",
 "haptics_leader": "a \"master manipulator\" box stands on the bench in the platform photo (Fig. 12); its design is N.R.; the tests were run from upper-computer software (Sec. V)",
 "imaging_compat": "N.R.",
 "sterility": "disposable surgical box holds every part that touches the catheter; reusable power unit below (Sec. II-B, Fig. 5)",
 "highest_validation": "bench",
 "validation_detail": "bench: 10 axial moves of 100 mm measured with a vernier caliper and 10 rotations of 60 deg measured with a protractor on the experimental platform (Sec. V, Figs. 12-14); no phantom. Alekseeva 2025 Table 9 lists it as TRL3 (ex vivo phantom).",
 "key_numbers": "axial error -0.65 to +0.62 mm per 100 mm move; rotation error -2 to +2 deg per 60 deg (Sec. V); calculated: 19.72 mm per feed-motor turn, max feed speed 3845.39 mm/s, 0.05 rad per rotation-motor turn, max rotation speed printed as 6.42 rad/s in Eq. 11 and 6.24 rad/s in the text (Sec. IV); friction wheel radius 14.5 mm; feed motor 11,700 rpm with reducer 4.62; rotation motor 7,600 rpm with reducer 62.01 and gear ratio 2:1 (Sec. IV)",
 "sim_model": "none found",
 "has_sim_model": false,
 "sim2real": "none-found",
 "sim2real_detail": "none found",
 "picture": {
  "status": "not-cleared",
  "grade": "C",
  "kind": "render",
  "source": "cao2024_cathdrive Fig. 1 overall CAD diagram, p. 2",
  "source_url": "https://doi.org/10.1109/IDITR62018.2024.10554319",
  "licence": "publisher copyright (IEEE)",
  "credit": "Cao et al., 2024 3rd International Conference on Innovations and Development of Information Technologies and Robotics (IDITR) (2024), Fig. 1. publisher copyright (IEEE).",
  "edits": "native extract; cropped off the label row and leader lines (box 0,84,620,480); two dashed red group boxes remain across the model; not upscaled",
  "file": null
 },
 "pictures": [
  {
   "id": "ujn_cao2024_01",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "setup",
   "caption": "Bench platform with PCs, master manipulator, drive and power supply (labelled)",
   "source_key": "cao2024_cathdrive",
   "source": "Cao et al., 2024 3rd International Conference on Innovations and Development of Information Technologies and Robotics (IDITR) (2024), Fig. 12, p. 6 (rendered at 300 dpi)",
   "source_url": "https://doi.org/10.1109/IDITR62018.2024.10554319",
   "where": "Fig. 12, p. 6 (rendered at 300 dpi)",
   "licence": "publisher copyright (IEEE)"
  },
  {
   "id": "ujn_cao2024_02",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "close-up",
   "caption": "Rotation test of the prototype gear with a protractor, two positions",
   "source_key": "cao2024_cathdrive",
   "source": "Cao et al., 2024 3rd International Conference on Innovations and Development of Information Technologies and Robotics (IDITR) (2024), Fig. 14, p. 6",
   "source_url": "https://doi.org/10.1109/IDITR62018.2024.10554319",
   "where": "Fig. 14, p. 6",
   "licence": "publisher copyright (IEEE)"
  },
  {
   "id": "ujn_cao2024_03",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "setup",
   "caption": "Axial feed test of the catheter measured with a vernier caliper",
   "source_key": "cao2024_cathdrive",
   "source": "Cao et al., 2024 3rd International Conference on Innovations and Development of Information Technologies and Robotics (IDITR) (2024), Fig. 13, p. 6",
   "source_url": "https://doi.org/10.1109/IDITR62018.2024.10554319",
   "where": "Fig. 13, p. 6",
   "licence": "publisher copyright (IEEE)"
  },
  {
   "id": "ujn_cao2024_04",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "render",
   "caption": "CAD section of the disposable surgical box on its motor base",
   "source_key": "cao2024_cathdrive",
   "source": "Cao et al., 2024 3rd International Conference on Innovations and Development of Information Technologies and Robotics (IDITR) (2024), Fig. 5(a), p. 3",
   "source_url": "https://doi.org/10.1109/IDITR62018.2024.10554319",
   "where": "Fig. 5(a), p. 3",
   "licence": "publisher copyright (IEEE)"
  },
  {
   "id": "ujn_cao2024_05",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "render",
   "caption": "CAD of the gear-driven circumferential rotation structure",
   "source_key": "cao2024_cathdrive",
   "source": "Cao et al., 2024 3rd International Conference on Innovations and Development of Information Technologies and Robotics (IDITR) (2024), Fig. 3, p. 3",
   "source_url": "https://doi.org/10.1109/IDITR62018.2024.10554319",
   "where": "Fig. 3, p. 3",
   "licence": "publisher copyright (IEEE)"
  }
 ],
 "sources": [
  {
   "key": "cao2024_cathdrive",
   "doi": "10.1109/IDITR62018.2024.10554319",
   "url": null,
   "title": "Design of Catheter Drive Mechanism for Vascular Interventional Surgery Robot",
   "year": 2024,
   "venue": "2024 3rd International Conference on Innovations and Development of Information Technologies and Robotics (IDITR)"
  },
  {
   "key": "alekseeva2025_design",
   "doi": "10.1002/rob.22480",
   "url": null,
   "title": "The Design of Endovascular Robots for Cardiac Interventions: A Survey",
   "year": 2024,
   "venue": "Journal of Field Robotics"
  }
 ],
 "read_level": "full",
 "read_level_detail": "full (cao2024_cathdrive); review-only (alekseeva2025_design Table 9 row 5)",
 "notes": "N2 2026-11-08, from review_comparison §1.2 row 26. Main picture is CAD: the only prototype photo (Fig. 12, platform) shows the drive about 200 px wide inside a red box; that photo is gallery picture 01. Alekseeva Fig. 12(a,b) draws the generic roller principle only.",
 "maintainers_own": false,
 "found_by": "gap"
}