 "schema_version": 1,
 "id": "surgipulse_chen2024",
 "name": "SurgiPulse",
 "full_name": "SurgiPulse robot-assisted mitral valve interventional repair system (robotic M-TEER)",
 "group": "SurgiPulse (Surgi-Pulse) Robotics Co., Ltd.; clinical: Xiamen Cardiovascular Hospital of Xiamen University (Yan Wang) and Fuwai Yunnan Hospital, Chinese Academy of Medical Sciences (Xiangbin Pan) (zhu2025_firstinman)",
 "group_short": "SurgiPulse Robotics",
 "family": "commercial",
 "category": "clinical-stage",
 "first_year": 2024,
 "latest_year": 2025,
 "versions": "2024 first-in-human robotic M-TEER (chen2024_firstinhuman; also Zhu D et al., JACC Cardiovasc Interv 2024;17:1505-1506, 'pure echo guidance', cited as zhu2025 ref. 1, not read) -> 2025 multicentre first-in-man series, 9 patients including 2 telerobotic over 5G (zhu2025_firstinman)",
 "target_anatomy": "structural heart: mitral valve (transcatheter edge-to-edge repair)",
 "devices": [
  "catheter",
  "sheath",
  "therapeutic-device"
 ],
 "devices_driven": "3 devices at once: three single-use sterile functional modules drive the steerable guiding catheter, the clip delivery catheter and the clip control sheath; compatible with MitraClip G4 (Abbott) and similar TEER systems; MitraClip G4 in 5 and Kyrin (Shenqi Medical) in 4 patients (zhu2025_firstinman); SQ-Kyrin-M in the 2024 case (chen2024_firstinhuman)",
 "n_dof": null,
 "n_dof_detail": "N.R. (five-joint positioning arm)",
 "translation_mechanism": "other",
 "translation_detail": "other: motorised sterile adapters on the TEER handles (mechanism N.R.)",
 "rotation_mechanism": "not-reported",
 "rotation_detail": "N.R.",
 "device_range": "N.R.",
 "footprint_mm": "N.R.",
 "mass_kg": "N.R.",
 "force_sensing": "N.R.",
 "haptics_leader": "control cockpit with 3 joysticks and buttons, one per control component (zhu2025_firstinman); doctor console with buttons and a rocker, on-site or remote (chen2024_firstinhuman); force feedback N.R.",
 "imaging_compat": "TEE (echo-guided) + fluoroscopy, operator outside the cath lab (chen2024_firstinhuman); 2 telerobotic procedures over 5G (zhu2025_firstinman)",
 "sterility": "3 single-use sterile functional modules (zhu2025_firstinman); sterile adapters between motors and instruments (chen2024_firstinhuman)",
 "highest_validation": "human",
 "validation_detail": "1 patient, 2 clips, MR severe -> mild, 29 min (chen2024_firstinhuman, PMC HTML); 9 patients, multicentre single-arm, 2 operators, 2 telerobotic via 5G; transseptal sheath placement and clip release done by hand (zhu2025_firstinman)",
 "key_numbers": "2024: procedure 29 min; baseline EROA 0.93 cm2, vena contracta 15.1 mm (chen2024_firstinhuman). 2025: 9/9 successful, 12 clips (7 MitraClip G4 XTW, 5 Kyrin), robotic time median 38 min (range 22-127), 36.5 min per clip; at 30 days MR <=2+ in all and 0-1+ in 7/9, NYHA I-II 8/9, no deaths, rehospitalisations or complications (zhu2025_firstinman)",
 "sim_model": "none found",
 "has_sim_model": false,
 "sim2real": "none-found",
 "sim2real_detail": "none found",
 "picture": {
  "status": "not-cleared",
  "grade": "A",
  "kind": "render",
  "source": "zhu2025_firstinman Fig. 1(A) (articulating arm with the three functional modules, control cockpit, trolley), JACC Cardiovasc Interv 2025;18:953-955, p. 2,",
  "source_url": "https://doi.org/10.1016/j.jcin.2025.01.437",
  "licence": "publisher copyright (ACC Foundation / Elsevier)",
  "credit": "Zhu et al., JACC: Cardiovascular Interventions (2025), Fig. 1. publisher copyright (ACC Foundation / Elsevier).",
  "edits": "starts from the X2 file (native extract, panel A, callouts filled); the inset photo with red/green/yellow boxes and its callout 1 (pixels (30,641)-(1218,1186)) replaced by a bilinear interpolation of the studio background sampled on the four sides of that rectangle plus 1 px gaussian grain (numpy, no inpainting model); nothing else changed; not upscaled",
  "file": null
 },
 "pictures": [
  {
   "id": "surgipulse_chen2024_01",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "render",
   "caption": "Rendering of the robotic positioning arm that carries the execution device",
   "source_key": "chen2024_firstinhuman",
   "source": "Chen et al., The International Journal of Cardiovascular Imaging (2024), graphical abstract panel B1, PMC11618145",
   "source_url": "https://doi.org/10.1007/s10554-024-03227-3",
   "where": "graphical abstract panel B1, PMC11618145",
   "licence": "CC BY-NC-ND 4.0"
  },
  {
   "id": "surgipulse_chen2024_02",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "leader",
   "caption": "Doctor console with touch screen and joysticks beside the echo display",
   "source_key": "chen2024_firstinhuman",
   "source": "Chen et al., The International Journal of Cardiovascular Imaging (2024), graphical abstract panel B2, PMC11618145",
   "source_url": "https://doi.org/10.1007/s10554-024-03227-3",
   "where": "graphical abstract panel B2, PMC11618145",
   "licence": "CC BY-NC-ND 4.0"
  },
  {
   "id": "surgipulse_chen2024_03",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "render",
   "caption": "Rendering of the robotic host trolley",
   "source_key": "chen2024_firstinhuman",
   "source": "Chen et al., The International Journal of Cardiovascular Imaging (2024), graphical abstract panel B3, PMC11618145",
   "source_url": "https://doi.org/10.1007/s10554-024-03227-3",
   "where": "graphical abstract panel B3, PMC11618145",
   "licence": "CC BY-NC-ND 4.0"
  },
  {
   "id": "surgipulse_chen2024_04",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "in-use",
   "caption": "Three functional modules holding the guide, clip delivery catheter and clip sheath (boxed)",
   "source_key": "zhu2025_firstinman",
   "source": "Zhu et al., JACC: Cardiovascular Interventions (2025), Fig. 1(A) inset, p. 2",
   "source_url": "https://doi.org/10.1016/j.jcin.2025.01.437",
   "where": "Fig. 1(A) inset, p. 2",
   "licence": "publisher copyright"
  },
  {
   "id": "surgipulse_chen2024_05",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "in-use",
   "caption": "Execution device with the TEER instruments mounted, first-in-human case",
   "source_key": "chen2024_firstinhuman",
   "source": "Chen et al., The International Journal of Cardiovascular Imaging (2024), graphical abstract panel A2, PMC11618145 (previous main picture)",
   "source_url": "https://doi.org/10.1007/s10554-024-03227-3",
   "where": "graphical abstract panel A2, PMC11618145 (previous main picture)",
   "licence": "CC BY-NC-ND 4.0"
  }
 ],
 "sources": [
  {
   "key": "chen2024_firstinhuman",
   "doi": "10.1007/s10554-024-03227-3",
   "url": null,
   "title": "First-in-human robotic-assisted transcatheter mitral edge-to-edge repair for treatment of severe mitral regurgitation",
   "year": 2024,
   "venue": "The International Journal of Cardiovascular Imaging"
  },
  {
   "key": "zhu2025_firstinman",
   "doi": "10.1016/j.jcin.2025.01.437",
   "url": null,
   "title": "First-in-Man Study of Robotic-Assisted Transcatheter Edge-to-Edge Repair",
   "year": 2025,
   "venue": "JACC: Cardiovascular Interventions"
  }
 ],
 "read_level": "full",
 "read_level_detail": "partial (PMC HTML via WebFetch, chen2024_firstinhuman); full (zhu2025_firstinman)",
 "notes": "Company product; structural-heart scope; may belong in A4's commercial list. A telerobotic 8-case M-TEER series attributed to SurgiPulse appears in a 2025 EuroIntervention review (WebSearch snippet, not verified). | X2 2026-11-08: zhu2025 read in full: 9 patients, 3 devices driven at once. Clinical site corrected to Fuwai Yunnan Hospital (Kunming). The 2024 echo-guided first-in-man letter (Zhu 2024) and chen2024 both claim a first case; whether they describe the same patient is not stated.",
 "maintainers_own": false,
 "found_by": "gap"
}