 "schema_version": 1,
 "id": "nagoya_negoro2001",
 "name": "Nagoya robot",
 "full_name": "Nagoya University catheter-driving robots for intravascular neurosurgery (roller and linear-stepping drives) with the EVE patient-specific simulator",
 "group": "Nagoya University (Toshio Fukuda, Fumihito Arai; neurosurgeon Makoto Negoro), later Seiichi Ikeda and Carlos Tercero",
 "group_short": "Nagoya U.",
 "family": "academic",
 "category": "academic",
 "first_year": 1996,
 "latest_year": 2010,
 "versions": "1996 ICRA networked telesurgery over optical fibre (arai1996_multimedia, doi:10.1109/ROBOT.1996.503883, title via dblp; cited as ref. 1 of tanimoto2000); 2000 MICCAI telesurgery system (tanimoto2000_telesurgery, full): 2-DOF roller slave whose outer shell turns for rotation, inner unit hung on strain-gauge beams (2-axis force), slave 'first designed in 1994' (Fig. 3), wire-driven 2-DOF master joystick (1.6 um, 0.023 deg encoders), 1.2 x 5 mm tip micro force sensor (0.5 mN, 2 kHz), in vitro telesurgery in an intravascular operating room with the doctor 5 m away watching X-ray (Sec. 3, 5); 2001 robotic controlled catheter system with motorized roller feeding (Negoro et al., via miyachi2025_robotics Fig. 1 and text); 2002 linear-stepping slave ('mechanical pencil' mechanism): two grasping units knocked by voice-coil motors, DC-motor rotation of the grasped catheter, voice-coil brake, disposable grasping unit, tip micro force sensor and force-feedback master joystick designed (arai2002_new, full; it replaces the 2000 roller slave, which slipped and was hard to sterilise); 2006 patient-specific neurovascular simulator EVE for evaluating robots (ikeda2006_patientspecific, title); 2007 IJMRCAS autonomous catheter insertion with magnetic motion capture (tercero2007_autonomous, full): the 2002 linear-stepping mechanism rebuilt as a stand-alone unit with a microcontroller, 2 DOF (insert/extract at variable speed, twist in one direction), steered by an NDI Aurora 0.8 x 8 mm coil (Sec. Catheter insertion mechanism, Fig. 2a); 2010 catheter insertion robot with photoelastic stress visualisation (ikeda2010_threedimensional, title)",
 "target_anatomy": "cerebral (intravascular neurosurgery)",
 "devices": [
  "catheter"
 ],
 "devices_driven": "catheter (4 Fr, 1.35 mm, in the 2002 tests; arai2002 Sec. 3)",
 "n_dof": 2,
 "n_dof_detail": "2 (forward/backward and rotation) for the 2002 slave (arai2002 Sec. 2.1)",
 "translation_mechanism": "friction-roller",
 "translation_detail": "friction-roller (2000-2001 roller feeding; arai2002 Sec. 1: when the vessel's resistance exceeds the pushing force, the roller slips); 2002 linear-stepping slave: two grasping units knocked by voice-coil motors, a brake holds the catheter between strokes (clamp-relay type; arai2002 Sec. 2.2)",
 "rotation_mechanism": "rotating-clamp",
 "rotation_detail": "2002: a DC motor (Table 1: 12 V, gear ratio 22:1) turns the grasping unit while it holds the catheter (arai2002 Sec. 2.2)",
 "device_range": "4 Fr catheter in the tests; step per cycle settable from 1 to 10 mm (arai2002 Sec. 3)",
 "footprint_mm": "2002 slave about 300 mm long (arai2002 Sec. 2.3: \"about 30cm\"); other dimensions N.R.",
 "mass_kg": "N.R.",
 "force_sensing": "2002: a micro force sensor at the catheter tip measures the catheter-vessel contact force for force feedback and the brake (arai2002 Sec. 2.3; no force data reported); none in the drive itself (he2018_linear Introduction); photoelastic stress in the phantom used to visualise wall stress (2010, title); 2000 roller slave: strain gauges on thin beams measure push and rotation reaction forces, plus a 1.2 mm x 5 mm tip micro force sensor (resolution 0.5 mN, 2 kHz) displayed together on the master (tanimoto2000 Sec. 3.2-4.1)",
 "haptics_leader": "2002: master joystick with force feedback designed (arai2002 Sec. 2.3, Fig. 10); not evaluated; 2000: 2-DOF force-reflecting master joystick (prismatic + revolute, wire-driven, no gears) with variable-impedance and multi-sensor force display (tanimoto2000 Sec. 3.1, 4)",
 "imaging_compat": "2000: in vitro telesurgery under the X-ray camera of an intravascular operating room, master in the next room (tanimoto2000 Sec. 5, Fig. 11); 2007: NDI Aurora magnetic motion capture (tercero2007)",
 "sterility": "2002: disposable grasping unit and brake contact part (arai2002 Sec. 2.1, 2.2); the earlier roller slave was not suitable for sterilisation (arai2002 Sec. 1)",
 "highest_validation": "phantom",
 "validation_detail": "in vitro patient-specific membranous silicone cerebral artery models (EVE) (ikeda2006_patientspecific, title-level); clinical use N.R.; 2001 system 'quite large', forward/backward only, not practical (miyachi2025_robotics) 2002 slave: bench only, catheter driven forward, backward and in rotation with the tip in a 5 mm pipe, distance by optical encoder (arai2002 Sec. 3, Figs. 12-18). 2000: in vitro telesurgery, soft plastic tube vessel model under X-ray in the intravascular operating room (tanimoto2000 Sec. 5). 2007: autonomous insertion in silicone block and membranous models of the aortic arch and carotids, speed control and 1-D / 2-D path reconstruction (tercero2007).",
 "key_numbers": "2002 slave: brake holding force about 220 gf, adjustable 0-300 gf (arai2002 Sec. 2.2); with the step set to 1 mm the measured step was 0.3-1.9 mm, so the stroke was \"not stable\" (Sec. 4, Fig. 18); slower than a roller drive (Sec. 2.1). Other papers not read. 2007: catheter speed controlled at 6.14 mm/s; 2-D path reproduced with < 7 mm error (tercero2007 Abstract).",
 "sim_model": "physical in vitro simulator (EVE), not a computational model; EVE phantoms are reused by later robot studies (e.g. A2 southeast_jin2024)",
 "has_sim_model": true,
 "sim2real": "none-found",
 "sim2real_detail": "none found",
 "picture": {
  "status": "not-cleared",
  "grade": "C",
  "kind": "photo",
  "source": "miyachi2025_robotics Fig. 1 'Robotic controlled catheter system developed in 2001', https://cdn.ncbi.nlm.nih.gov/pmc/blobs/8a6f/11911030/f1717870653b/jnet-19-01-2024-0112-g001.jpg (page https://pmc.ncbi.nlm.nih.gov/articles/PMC11911030/)",
  "source_url": "https://doi.org/10.5797/jnet.ra.2024-0112",
  "licence": "CC BY-NC 4.0",
  "credit": "Miyachi et al., Journal of Neuroendovascular Therapy (2025), Fig. 1. CC BY-NC 4.0.",
  "edits": "PMC image as served; no edits; not upscaled (a Real-ESRGAN trial was discarded: painterly artefacts; upscaling now disabled)",
  "file": null
 },
 "pictures": [
  {
   "id": "nagoya_negoro2001_01",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "photo",
   "caption": "2002 linear-stepping slave: brake, voice coil motor, catheter grasper",
   "source_key": "arai2002_new",
   "source": "Arai et al., Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292) (), Fig. 11, p. 5",
   "source_url": "https://doi.org/10.1109/robot.2002.1013679",
   "where": "Fig. 11, p. 5",
   "licence": "publisher copyright"
  },
  {
   "id": "nagoya_negoro2001_02",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "close-up",
   "caption": "Grasping unit parts of the linear-stepping drive",
   "source_key": "arai2002_new",
   "source": "Arai et al., Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292) (), Fig. 1, p. 2",
   "source_url": "https://doi.org/10.1109/robot.2002.1013679",
   "where": "Fig. 1, p. 2",
   "licence": "publisher copyright"
  },
  {
   "id": "nagoya_negoro2001_03",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "photo",
   "caption": "2000 slave: roller unit inside a rotating outer shell, first designed in 1994",
   "source_key": "tanimoto2000_telesurgery",
   "source": "Tanimoto et al., Medical Image Computing and Computer-Assisted Intervention – MICCAI 2000 (2000), Fig. 3, p. 32",
   "source_url": "https://doi.org/10.1007/978-3-540-40899-4_4",
   "where": "Fig. 3, p. 32",
   "licence": "publisher copyright (Springer)"
  },
  {
   "id": "nagoya_negoro2001_04",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "leader",
   "caption": "2000 master joystick: wire-driven prismatic and revolute joints",
   "source_key": "tanimoto2000_telesurgery",
   "source": "Tanimoto et al., Medical Image Computing and Computer-Assisted Intervention – MICCAI 2000 (2000), Fig. 1, p. 32",
   "source_url": "https://doi.org/10.1007/978-3-540-40899-4_4",
   "where": "Fig. 1, p. 32",
   "licence": "publisher copyright (Springer)"
  },
  {
   "id": "nagoya_negoro2001_05",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "close-up",
   "caption": "Micro force sensor at the catheter tip, 1.2 mm diameter",
   "source_key": "tanimoto2000_telesurgery",
   "source": "Tanimoto et al., Medical Image Computing and Computer-Assisted Intervention – MICCAI 2000 (2000), Fig. 6, p. 34",
   "source_url": "https://doi.org/10.1007/978-3-540-40899-4_4",
   "where": "Fig. 6, p. 34",
   "licence": "publisher copyright (Springer)"
  },
  {
   "id": "nagoya_negoro2001_06",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "in-use",
   "caption": "2007 linear-stepping unit inserting a sensor catheter into a silicone arterial model",
   "source_key": "tercero2007_autonomous",
   "source": "Tercero et al., The International Journal of Medical Robotics and Computer Assisted Surgery (2006), Fig. 2(a), p. 54",
   "source_url": "https://doi.org/10.1002/rcs.116",
   "where": "Fig. 2(a), p. 54",
   "licence": "publisher copyright (Wiley)"
  }
 ],
 "sources": [
  {
   "key": "miyachi2025_robotics",
   "doi": "10.5797/jnet.ra.2024-0112",
   "url": null,
   "title": "Robotics for Neuroendovascular Therapy",
   "year": 2025,
   "venue": "Journal of Neuroendovascular Therapy"
  },
  {
   "key": "tanimoto2000_telesurgery",
   "doi": "10.1007/978-3-540-40899-4_4",
   "url": null,
   "title": "Telesurgery System for Intravascular Neurosurgery",
   "year": 2000,
   "venue": "Medical Image Computing and Computer-Assisted Intervention – MICCAI 2000"
  },
  {
   "key": "arai2002_new",
   "doi": "10.1109/robot.2002.1013679",
   "url": null,
   "title": "New catheter driving method using linear stepping mechanism for intravascular neurosurgery",
   "year": null,
   "venue": "Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292)"
  },
  {
   "key": "ikeda2006_patientspecific",
   "doi": "10.1109/robot.2006.1641780",
   "url": null,
   "title": "Patient-specific neurovascular simulator for evaluating the performance of medical robots and instrumens",
   "year": null,
   "venue": "Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. ICRA 2006."
  },
  {
   "key": "tercero2007_autonomous",
   "doi": "10.1002/rcs.116",
   "url": null,
   "title": "Autonomous catheter insertion system using magnetic motion capture sensor for endovascular surgery",
   "year": 2006,
   "venue": "The International Journal of Medical Robotics and Computer Assisted Surgery"
  },
  {
   "key": "ikeda2010_threedimensional",
   "doi": "10.1109/iros.2010.5650275",
   "url": null,
   "title": "Three-dimensional visualization of photoelastic stress analysis for catheter insertion robot",
   "year": 2010,
   "venue": "2010 IEEE/RSJ International Conference on Intelligent Robots and Systems"
  },
  {
   "key": "he2018_linear",
   "doi": "10.1007/s11548-018-1722-x",
   "url": null,
   "title": "A linear stepping endovascular intervention robot with variable stiffness and force sensing",
   "year": 2018,
   "venue": "International Journal of Computer Assisted Radiology and Surgery"
  },
  {
   "key": "arai1996_multimedia",
   "doi": "10.1109/robot.1996.503883",
   "url": null,
   "title": "Multimedia tele-surgery using high speed optical fiber network and its application to intravascular neurosurgery - system configuration and computer networked robotic implementation",
   "year": 1996,
   "venue": "Proceedings of IEEE International Conference on Robotics and Automation"
  }
 ],
 "read_level": "full",
 "read_level_detail": "review (miyachi2025_robotics full); full (arai2002_new, 2026-10-14); full (tanimoto2000_telesurgery, tercero2007_autonomous, 2026-11-08); title (arai1996_multimedia, ikeda2006_patientspecific, ikeda2010_threedimensional)",
 "notes": "Attribution of the 2001 photo to the Nagoya line rests on miyachi2025 ref. 1 (Negoro et al.); Negoro is a co-author of arai2002_new. Springer MICCAI 2000 full text failed verification twice (manual list). F4 2026-10-14: arai2002 Fig. 11, the only photo of the 2002 slave, is a dark halftone scan about 650 px wide with labels printed on it; the 2001 photo stays. | 2026-11-08 X3: first_year 2000 -> 1996: tanimoto2000 cites Arai et al. ICRA 1996 (doi:10.1109/ROBOT.1996.503883) as the group's earlier telesurgery work, and its Fig. 3 caption says the slave was first designed in 1994. The 2000 slave photo (Fig. 3) is clean but 318 px, so the main picture stays the 2001 photo; it is in the gallery",
 "maintainers_own": false,
 "found_by": "gap"
}