 "schema_version": 1,
 "id": "mitmagwire_kim2022",
 "name": "Magnetic soft wire",
 "full_name": "MIT telerobotic magnetic soft guidewire system",
 "group": "Zhao lab, MIT, with Massachusetts General Hospital / Harvard Medical School (neurosurgery), University of Cincinnati and Philips Research North America; animal work under UMass Medical School IACUC (kim2022_telerobotic affiliations, p. 18)",
 "group_short": "MIT",
 "family": "magnetic",
 "category": "magnetic-navigation",
 "first_year": 2019,
 "latest_year": 2022,
 "versions": "2019 ferromagnetic soft continuum robots: device only, magnet moved by hand and wire pushed by hand (kim2019_ferromagnetic); 2022 telerobotic system: KUKA arm with a 100 mm magnet, two motorised advancers, remote console, 400 um wire, pig (kim2022_telerobotic)",
 "target_anatomy": "neuro (phantoms, porcine brachial artery with accentuated tortuosity)",
 "devices": [
  "guidewire",
  "microcatheter",
  "sheath",
  "therapeutic-device"
 ],
 "devices_driven": "2 devices, driven independently or simultaneously: own magnetic soft guidewire, 400 um OD (tapered nitinol core in a TPU jacket with 20 vol% NdFeB, magnetically responsive distal 50 mm, coreless 4 mm tip) and a microcatheter; 0.0115-in coils and a Solitaire X stent retriever delivered through it; 7 F sheath (kim2022_telerobotic p. 3-4, 18); 2019 prototypes 600 um (PDMS + NdFeB, 80 um nitinol core) and 810 um (TPU + NdFeB) (kim2019_ferromagnetic)",
 "n_dof": 7,
 "n_dof_detail": "7-DOF arm (KUKA LBR Med 14 R820) sets the magnet pose (6-DOF end-effector control; pole flipped by turning axis 7 by 180 degrees) + 2 linear advancing units for wire and microcatheter (kim2022_telerobotic p. 3, 7, 17)",
 "translation_mechanism": "magnetic",
 "translation_detail": "magnetic (steering); insertion by two commercial worm-drive advancers (Stereotaxis QuikCAS Cardiodrive) driven by DC gearmotors through flexible shafts (kim2022_telerobotic p. 3, 18)",
 "rotation_mechanism": "magnetic-field",
 "rotation_detail": "field direction, no shaft rotation",
 "device_range": "magnet working distance d/R 2.64-3.67, i.e. 80-30 mT at the tip (kim2022_telerobotic p. 7)",
 "footprint_mm": "N.R. (arm on a mobile platform beside the operating table, kim2022_telerobotic p. 3)",
 "mass_kg": "magnet and fixture 7 kg (kim2022_telerobotic p. 18); arm N.R.",
 "force_sensing": "none: 'the advancing unit of our system does not provide any tactile or haptic feedback' (kim2022_telerobotic p. 17)",
 "haptics_leader": "no haptics: remote console a few metres away with a 6-DOF SpaceMouse Pro knob and buttons to advance/retract; ROS MoveIt/RViz virtual view (kim2022_telerobotic p. 17-18)",
 "imaging_compat": "real-time fluoroscopy, DSA roadmaps, 3D rotational angiography; the NdFeB particles make the wire radiopaque; compatible with standard biplane fluoroscopy (kim2022_telerobotic p. 8, 17)",
 "sterility": "N.R.",
 "highest_validation": "animal",
 "validation_detail": "head phantom under fluoroscopy (navigation 45.0 +- 4.0 s, n = 5); MCA aneurysm coiling and clot retrieval in phantoms (n = 3 each); 1 pig (56 kg Yorkshire, brachial-artery tortuosity model, 124.6 +- 19.7 s, n = 5); learning curve 6 novices and 2 experienced users x 15 trials; robot vs manual: one interventionalist, 10 trials each (kim2022_telerobotic pp. 8-16, 18)",
 "key_numbers": "robot vs manual 42.9 +- 10.5 vs 63.7 +- 22.4 s (P < 0.05); the manual wire crossed the siphon aneurysm in 5 of 10 trials; field at most 80 mT, gradient 1.75 mT/mm; N52 cylindrical magnet 100 mm diameter x 100 mm; tip deflection about 120 deg (attraction) and 90 deg (repulsion) (kim2022_telerobotic pp. 5-16)",
 "sim_model": "field maps in COMSOL; 2019 Abaqus finite-element model of the soft continuum robot (kim2019_ferromagnetic p. 13); MoveIt/RViz virtual scene used to plan magnet poses; magnet pose from joystick input via a Jacobian pseudo-inverse, no guidewire model in the loop (kim2022_telerobotic p. 17)",
 "has_sim_model": true,
 "sim2real": "none-found",
 "sim2real_detail": "none found (no learned controller in kim2019 or kim2022)",
 "picture": {
  "status": "not-cleared",
  "grade": "A",
  "kind": "photo",
  "source": "MIT News press image MIT-Robo-Stroke-02-press.jpg (left panel: robot arm with actuating magnet over the neurovascular phantom), news.mit.edu/sites/default/files/download/202204/",
  "source_url": null,
  "licence": "CC BY-NC-ND (MIT News terms: no alteration other than cropping; credit \"Courtesy of the researchers\")",
  "credit": "MIT News press image MIT-Robo-Stroke-02-press.jpg (left panel: robot arm with actuating magnet over the neurovascular phantom), news.mit.edu/sites/default/files/download/202204/. Licence: CC BY-NC-ND (MIT News terms: no alteration other than cropping; credit \"Courtesy of the researchers\").",
  "edits": "crop; 2 label areas on the plain black background set to black; white text \"Neurovascular Phantom\" over the phantom erased (LaMa, text mask only)",
  "file": null
 },
 "pictures": [
  {
   "id": "mitmagwire_kim2022_01",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "close-up",
   "caption": "Motorized guidewire and microcatheter advancement unit at the phantom inlet",
   "source_key": "kim2022_telerobotic",
   "source": "Kim et al., Science Robotics (2022), MIT News press image MIT-Robo-Stroke-02-press.jpg, right panel; news.mit.edu/sites/default/files/download/202204/",
   "source_url": "https://doi.org/10.1126/scirobotics.abg9907",
   "where": "MIT News press image MIT-Robo-Stroke-02-press.jpg, right panel; news.mit.edu/sites/default/files/download/202204/",
   "licence": "CC BY-NC-ND (MIT News press image; crop only)"
  },
  {
   "id": "mitmagwire_kim2022_02",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "render",
   "caption": "Renderings of the robot arm and magnet over a patient beside a C-arm",
   "source_key": "kim2022_telerobotic",
   "source": "Kim et al., Science Robotics (2022), MIT News press image MIT-Robo-Stroke-01-press.jpg, right panels",
   "source_url": "https://doi.org/10.1126/scirobotics.abg9907",
   "where": "MIT News press image MIT-Robo-Stroke-01-press.jpg, right panels",
   "licence": "CC BY-NC-ND (MIT News press image; crop only)"
  },
  {
   "id": "mitmagwire_kim2022_03",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "render",
   "caption": "System drawing: 7-DOF arm with magnet, wire advancers and joystick console",
   "source_key": "kim2022_telerobotic",
   "source": "Kim et al., Science Robotics (2022), Fig. 2, PMC9254892",
   "source_url": "https://doi.org/10.1126/scirobotics.abg9907",
   "where": "Fig. 2, PMC9254892",
   "licence": "publisher copyright (NIH author manuscript PMC9254892)"
  },
  {
   "id": "mitmagwire_kim2022_04",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "render",
   "caption": "Overview drawing of the telerobotic platform on a mobile cart at the C-arm",
   "source_key": "kim2022_telerobotic",
   "source": "Kim et al., Science Robotics (2022), Fig. 1, PMC9254892",
   "source_url": "https://doi.org/10.1126/scirobotics.abg9907",
   "where": "Fig. 1, PMC9254892",
   "licence": "publisher copyright (NIH author manuscript PMC9254892)"
  },
  {
   "id": "mitmagwire_kim2022_05",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "in-use",
   "caption": "Arm placing the magnet over the head phantom under the C-arm: actual and virtual views",
   "source_key": "kim2022_telerobotic",
   "source": "Kim et al., Science Robotics (2022), Fig. 4(E-F), p. 8",
   "source_url": "https://doi.org/10.1126/scirobotics.abg9907",
   "where": "Fig. 4(E-F), p. 8",
   "licence": "publisher copyright"
  },
  {
   "id": "mitmagwire_kim2022_06",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "in-use",
   "caption": "Arm placing the magnet over the anaesthetised pig: virtual and actual views",
   "source_key": "kim2022_telerobotic",
   "source": "Kim et al., Science Robotics (2022), Fig. 7(E-F), p. 13",
   "source_url": "https://doi.org/10.1126/scirobotics.abg9907",
   "where": "Fig. 7(E-F), p. 13",
   "licence": "publisher copyright"
  },
  {
   "id": "mitmagwire_kim2022_07",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "render",
   "caption": "Drawing of the arm and magnet beside the C-arm around the porcine model",
   "source_key": "kim2022_telerobotic",
   "source": "Kim et al., Science Robotics (2022), Fig. 7(C), p. 13",
   "source_url": "https://doi.org/10.1126/scirobotics.abg9907",
   "where": "Fig. 7(C), p. 13",
   "licence": "publisher copyright"
  },
  {
   "id": "mitmagwire_kim2022_08",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "leader",
   "caption": "Neurointerventionalist at the remote console and with a conventional guidewire for comparison",
   "source_key": "kim2022_telerobotic",
   "source": "Kim et al., Science Robotics (2022), Fig. 8(A), p. 15",
   "source_url": "https://doi.org/10.1126/scirobotics.abg9907",
   "where": "Fig. 8(A), p. 15",
   "licence": "publisher copyright"
  }
 ],
 "sources": [
  {
   "key": "kim2022_telerobotic",
   "doi": "10.1126/scirobotics.abg9907",
   "url": null,
   "title": "Telerobotic neurovascular interventions with magnetic manipulation",
   "year": 2022,
   "venue": "Science Robotics"
  },
  {
   "key": "kim2019_ferromagnetic",
   "doi": "10.1126/scirobotics.aax7329",
   "url": null,
   "title": "Ferromagnetic soft continuum robots",
   "year": 2019,
   "venue": "Science Robotics"
  }
 ],
 "read_level": "full",
 "read_level_detail": "full (kim2019_ferromagnetic, kim2022_telerobotic)",
 "notes": "Highest-profile magnetic guidewire. Mount Sinai does not appear in either paper (corrected to MGH / Cincinnati / Philips). The earlier Dryad-based 0.72-0.91 mm diameter guess is replaced by the stated 400 um. | X2 2026-11-08: raised to full text.",
 "maintainers_own": false,
 "found_by": "actuated-tip"
}