{
 "schema_version": 1,
 "id": "kclneuro_sadati2025",
 "name": "KCL lead-screw",
 "full_name": "KCL lead-screw neurointervention manipulator",
 "group": "King's College London (Booth, Bergeles; Robertshaw, Jackson, Chen)",
 "group_short": "KCL",
 "family": "academic",
 "category": "academic",
 "first_year": 2025,
 "latest_year": 2026,
 "versions": "Hamlyn Symposium 2025 (Sadati, long CTR in vitro); RA-L 2026 HM-MARL; IROS 2026 world model; arXiv 2026 progressive fusion; arXiv 2607.07253 haptic leader study",
 "target_anatomy": "neurovascular: femoral artery to carotid / ICA in printed phantoms of patient CTA",
 "devices": [
  "guidewire",
  "microcatheter",
  "catheter",
  "therapeutic-device"
 ],
 "devices_driven": "0.035 in guidewire (180 cm Terumo) + 0.058 in Navien support catheter (125 cm) (towardb); jackson2026: Terumo Glidewire + Penumbra SlipCath Beacon, Penumbra Neuron MAX fixed (Sec. III-B); concentric shafts allow up to three devices (guidewires, microcatheters, stent retrievers; jackson2026 Sec. II-B)",
 "n_dof": 2,
 "n_dof_detail": "2 per carriage (translation, rotation); 4 with two devices",
 "translation_mechanism": "linear-stage+clamp",
 "translation_detail": "linear-stage+clamp (carriages on one 1 m, 2 mm-pitch lead screw; telescopic tubes between carriages against buckling)",
 "rotation_mechanism": "rotating-clamp",
 "rotation_detail": "hollow-shaft NEMA 17 stepper per carriage with drill-chuck coupling",
 "device_range": "two device sizes used; range N.R.",
 "footprint_mm": "1 m lead screw on 20x20 mm aluminium frame; other dimensions N.R.",
 "mass_kg": "N.R.",
 "force_sensing": "ATI Mini 58 six-DOF force sensor in the guidewire carriage, proximal axial/lateral/torsional forces at 250 Hz (jackson2026 Sec. II-B, Fig. 2(c)); phantom with eight piezoresistive wall-force sensors (Fig. 3)",
 "haptics_leader": "yes in jackson2026_manual: device-mimicking dual-device handle (buttons select catheter, guidewire or both) on MyActuator RMD-L 4015 brushless motors, force reflection at 250 Hz; compared with manual, joystick and haptics-off (Sec. II-A, Fig. 1)",
 "imaging_compat": "overhead camera or mobile C-arm (Siemens Cios Spin) tracking; robot and phantom under the mobile C-arm in a mock angiography suite (jackson2026 Fig. 4(a)); no MR claim",
 "sterility": "N.R.",
 "highest_validation": "phantom",
 "validation_detail": "in-vitro printed phantoms: 10 episodes per task (HM-MARL), 5 runs per task n=25 (world model), 5 runs per sub-task (progressive); 10 neuroradiologists x 8 runs in the haptic leader study",
 "key_numbers": "HM-MARL in vitro right ICA 100% (A12) and 70-80% (A23), left 0%; manual expert 10/10 right, 2/10 left; world model 68% vs SAC 60% in vitro; max 40 mm/s translation, 180 deg/s rotation",
 "sim_model": "yes: stEVE / SOFA BeamAdapter patient-specific CTA models (Navien and Terumo wire, E = 47 and 43 MPa) - robertshaw2026_towardb",
 "has_sim_model": true,
 "sim2real": "yes",
 "sim2real_detail": "yes: hierarchical multi-agent SAC (RA-L 2026): sim 92-100% single anatomy -> in vitro 100/70-80% right, 0% left; TD-MPC2 world model 58% sim holdout -> 68% bench; progressive fusion 90% sim -> 60/67% bench (the sim-to-real study table, robertshaw2026_towardb read full)",
 "picture": {
  "status": "cleared",
  "grade": "C",
  "kind": "photo",
  "source": "jackson2026_manual Fig. 2 (arXiv 2607.07253v1 HTML figure https://arxiv.org/html/2607.07253v1/Figs_robot_figure.png; page https://arxiv.org/html/2607.07253)",
  "source_url": "https://arxiv.org/abs/2607.07253v1",
  "licence": "CC BY 4.0",
  "credit": "Jackson et al., 2026, Fig. 2. CC BY 4.0.",
  "edits": "downloaded PNG 2888x989; cropped; letter tags a-e and their white arrows kept (arrows end on the frame and motors); not upscaled",
  "file": "pictures/kclneuro_sadati2025.jpg"
 },
 "pictures": [
  {
   "id": "kclneuro_sadati2025_01",
   "status": "cleared",
   "file": "pictures/extra/kclneuro_sadati2025_01.jpg",
   "thumb": "pictures/thumbs/kclneuro_sadati2025_01.jpg",
   "kind": "in-use",
   "caption": "Lead-screw manipulator beside a vascular phantom on the table under a mobile C-arm",
   "source_key": "robertshaw2026_safe",
   "source": "Robertshaw et al. (2026), Fig. 2, p. 3 (arXiv 2604.20151v1)",
   "source_url": "https://arxiv.org/abs/2604.20151",
   "where": "Fig. 2, p. 3 (arXiv 2604.20151v1)",
   "licence": "CC BY 4.0"
  },
  {
   "id": "kclneuro_sadati2025_02",
   "status": "cleared",
   "file": "pictures/extra/kclneuro_sadati2025_02.jpg",
   "thumb": "pictures/thumbs/kclneuro_sadati2025_02.jpg",
   "kind": "photo",
   "caption": "Long concentric-tube manipulator: lead-screw guide rail, telescopic tubes, actuation units",
   "source_key": "robertshaw2026_towardb",
   "source": "Robertshaw et al., IEEE Robotics and Automation Letters (2026), Fig. 3, p. 4 (arXiv 2602.18663v1)",
   "source_url": "https://doi.org/10.1109/lra.2026.3664661",
   "where": "Fig. 3, p. 4 (arXiv 2602.18663v1)",
   "licence": "CC BY 4.0"
  },
  {
   "id": "kclneuro_sadati2025_03",
   "status": "cleared",
   "file": "pictures/extra/kclneuro_sadati2025_03.jpg",
   "thumb": "pictures/thumbs/kclneuro_sadati2025_03.jpg",
   "kind": "in-use",
   "caption": "Robot and force-sensing phantom under a mobile C-arm in a mock angiography suite",
   "source_key": "jackson2026_manual",
   "source": "Jackson et al. (2026), Fig. 4(a), p. 4 (arXiv 2607.07253v1)",
   "source_url": "https://arxiv.org/abs/2607.07253",
   "where": "Fig. 4(a), p. 4 (arXiv 2607.07253v1)",
   "licence": "CC BY 4.0"
  },
  {
   "id": "kclneuro_sadati2025_04",
   "status": "cleared",
   "file": "pictures/extra/kclneuro_sadati2025_04.jpg",
   "thumb": "pictures/thumbs/kclneuro_sadati2025_04.jpg",
   "kind": "leader",
   "caption": "Device-mimicking haptic controller: handle, brushless motors, mode buttons",
   "source_key": "jackson2026_manual",
   "source": "Jackson et al. (2026), Fig. 1, p. 2 (arXiv 2607.07253v1)",
   "source_url": "https://arxiv.org/abs/2607.07253",
   "where": "Fig. 1, p. 2 (arXiv 2607.07253v1)",
   "licence": "CC BY 4.0"
  },
  {
   "id": "kclneuro_sadati2025_05",
   "status": "cleared",
   "file": "pictures/extra/kclneuro_sadati2025_05.jpg",
   "thumb": "pictures/thumbs/kclneuro_sadati2025_05.jpg",
   "kind": "leader",
   "caption": "Neuroradiologist teleoperating the robot from the control room",
   "source_key": "jackson2026_manual",
   "source": "Jackson et al. (2026), Fig. 4(b), p. 4 (arXiv 2607.07253v1)",
   "source_url": "https://arxiv.org/abs/2607.07253",
   "where": "Fig. 4(b), p. 4 (arXiv 2607.07253v1)",
   "licence": "CC BY 4.0"
  }
 ],
 "sources": [
  {
   "key": "robertshaw2026_towardb",
   "doi": "10.1109/lra.2026.3664661",
   "url": null,
   "title": "Toward AI Autonomous Navigation for Mechanical Thrombectomy Using Hierarchical Modular Multi-Agent Reinforcement Learning (HM-MARL)",
   "year": 2026,
   "venue": "IEEE Robotics and Automation Letters"
  },
  {
   "key": "robertshaw2026_safe",
   "doi": null,
   "url": "https://arxiv.org/abs/2604.20151",
   "title": "Toward Safe Autonomous Robotic Endovascular Interventions using World Models",
   "year": 2026,
   "venue": null
  },
  {
   "key": "robertshaw2026_progressive",
   "doi": null,
   "url": "https://arxiv.org/abs/2608.18647",
   "title": "Progressive Experience Fusion for Multi-Task World Model Control in Endovascular Navigation",
   "year": 2026,
   "venue": null
  },
  {
   "key": "jackson2026_manual",
   "doi": null,
   "url": "https://arxiv.org/abs/2607.07253",
   "title": "Manual, Joystick, or Haptic Control? An In Vitro Comparison of Navigation Strategies for Robotic Interventional Neuroradiology Procedures",
   "year": 2026,
   "venue": null
  }
 ],
 "read_level": "full",
 "read_level_detail": "full",
 "notes": "Fig. 3 caption of towardb calls the device a 'concentric tube robot' [Sadati 2025]; id kclneuro_sadati2025 is the proposed id in the sim-to-real study table. | 2026-11-08 X3: jackson2026 read in full: two NEMA 17 steppers (24 V, 600 mA, 80 Ncm), one for lead-screw translation and one for rotation; scissor-frame and telescopic-tube anti-buckling (Sec. II-B); 10 neuroradiologists (4 novices, 6 experts) x 8 navigations; wall forces stayed below 0.70 N with every controller; manual 47.7 s vs haptic-on 248.7 s, haptic-off 314.7 s, joystick 392.6 s (Abstract)",
 "maintainers_own": false,
 "found_by": "academic"
}
