 "schema_version": 1,
 "id": "kcl_tsp_zeidan2023",
 "name": "Transseptal robot",
 "full_name": "KCL force-sensing robot for transseptal puncture (needle and dilator-sheath manipulator)",
 "group": "King's College London (K. Rhode; A. M. Zeidan, Z. Xu, C. E. Mower) with Brunel University London (Y. Noh) and Guy's and St Thomas'",
 "group_short": "KCL",
 "family": "academic",
 "category": "academic",
 "first_year": 2023,
 "latest_year": 2023,
 "versions": "2023 ICRA (only); 2016: KCL 3-DOF MR-compatible multisegment cardiac catheter steering mechanism (Ataollahi 2016 TBME) (Belikov 2024 Fig. 5 AT1; Pescio 2025 Table 2 row 10) (belikov2024_evolution; pescio2025_endovascular); 2015-19: KCL (K. Rhode, H. Liu, J. Back) tendon-driven catheter robot with tension sensing (Back 2015; model-free position control Back 2017), likely the same hardware as Z. Zhang 2019 RA-L cable-driven continuum catheter control with Inria (Belikov 2024 Fig. 5 AT2, JEs) (belikov2024_evolution)",
 "target_anatomy": "interatrial septum (transseptal puncture before left-atrial ablation)",
 "devices": [
  "sheath"
 ],
 "devices_driven": "standard transseptal kit: 8.5 Fr SL0 sheath (St Jude), Torflex dilator (Baylis), BRK-1 Brockenbrough needle (71 cm) (Sec. I)",
 "n_dof": 4,
 "n_dof_detail": "4 actuated (translation and rotation of needle and of dilator-sheath), 2 task-space DOF",
 "translation_mechanism": "linear-stage+clamp",
 "translation_detail": "linear-stage+clamp (lead screws on NEMA-17 steppers M1, M2 move needle and dilator-sheath carriages)",
 "rotation_mechanism": "other",
 "rotation_detail": "NEMA-17 steppers M3, M4 rotate needle and sheath continuously",
 "device_range": "one transseptal kit",
 "footprint_mm": "N.R.",
 "mass_kg": "N.R.",
 "force_sensing": "optoelectronic sensors (New Japan Radio) in the tool fixtures measure contact and puncture force along one axis",
 "haptics_leader": "N.R.",
 "imaging_compat": "N.R.",
 "sterility": "N.R.",
 "highest_validation": "bench",
 "validation_detail": "puncture experiments on anthropomorphic fossa-ovalis tissue models (Sec. IV)",
 "key_numbers": "puncture force 3.97 +- 0.45 N (1 SD), similar to manual values in the literature (abstract)",
 "sim_model": "none found",
 "has_sim_model": false,
 "sim2real": "none-found",
 "sim2real_detail": "none found",
 "picture": {
  "status": "not-cleared",
  "grade": "C",
  "kind": "photo",
  "source": "zeidan2023_transseptal_ICRA Fig. 6 (force-testing set-up), left part: the 4-stepper TSP robot",
  "source_url": "https://doi.org/10.1109/icra48891.2023.10160254",
  "licence": "publisher copyright (IEEE version); authors applied CC BY to the accepted manuscript (not obtained)",
  "credit": "Zeidan et al., 2023 IEEE International Conference on Robotics and Automation (ICRA) (2023), Fig. 6. publisher copyright (IEEE version); authors applied CC BY to the accepted manuscript (not obtained).",
  "edits": "native extract (1168x414); cropped to the robot, excluding the label arrow and red puncture inset; not upscaled",
  "file": null
 },
 "pictures": [
  {
   "id": "kcl_tsp_zeidan2023_01",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "setup",
   "caption": "Force-testing set-up: robot feeding the TSP kit through a tube to a fossa ovalis model",
   "source_key": "zeidan2023_design",
   "source": "Zeidan et al., 2023 IEEE International Conference on Robotics and Automation (ICRA) (2023), Fig. 6, p. 6",
   "source_url": "https://doi.org/10.1109/icra48891.2023.10160254",
   "where": "Fig. 6, p. 6",
   "licence": "publisher copyright (IEEE)"
  },
  {
   "id": "kcl_tsp_zeidan2023_02",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "render",
   "caption": "CAD of the robot: needle and dilator-sheath stages, circuit housing, OLED display",
   "source_key": "zeidan2023_design",
   "source": "Zeidan et al., 2023 IEEE International Conference on Robotics and Automation (ICRA) (2023), Fig. 2, upper left view, p. 2",
   "source_url": "https://doi.org/10.1109/icra48891.2023.10160254",
   "where": "Fig. 2, upper left view, p. 2",
   "licence": "publisher copyright (IEEE)"
  },
  {
   "id": "kcl_tsp_zeidan2023_03",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "render",
   "caption": "CAD of the needle and dilator-sheath fixtures with master switch",
   "source_key": "zeidan2023_design",
   "source": "Zeidan et al., 2023 IEEE International Conference on Robotics and Automation (ICRA) (2023), Fig. 2, upper right view, p. 2",
   "source_url": "https://doi.org/10.1109/icra48891.2023.10160254",
   "where": "Fig. 2, upper right view, p. 2",
   "licence": "publisher copyright (IEEE)"
  },
  {
   "id": "kcl_tsp_zeidan2023_04",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "render",
   "caption": "CAD top view: four NEMA17 steppers, lead screws and limit switches",
   "source_key": "zeidan2023_design",
   "source": "Zeidan et al., 2023 IEEE International Conference on Robotics and Automation (ICRA) (2023), Fig. 2, lower left view, p. 2",
   "source_url": "https://doi.org/10.1109/icra48891.2023.10160254",
   "where": "Fig. 2, lower left view, p. 2",
   "licence": "publisher copyright (IEEE)"
  },
  {
   "id": "kcl_tsp_zeidan2023_05",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "close-up",
   "caption": "Exploded CAD of the force-sensing fixtures with cantilever beams and reflectors",
   "source_key": "zeidan2023_design",
   "source": "Zeidan et al., 2023 IEEE International Conference on Robotics and Automation (ICRA) (2023), Fig. 2, lower right view, p. 2 (accepted manuscript, Brunel BURA 2438/28704, embedded 8713 px)",
   "source_url": "https://doi.org/10.1109/icra48891.2023.10160254",
   "where": "Fig. 2, lower right view, p. 2 (accepted manuscript, Brunel BURA 2438/28704, embedded 8713 px)",
   "licence": "publisher copyright (IEEE); accepted manuscript says authors applied CC BY, repository record says IEEE rights"
  }
 ],
 "sources": [
  {
   "key": "zeidan2023_design",
   "doi": "10.1109/icra48891.2023.10160254",
   "url": null,
   "title": "Design and Development of a Novel Force-Sensing Robotic System for the Transseptal Puncture in Left Atrial Catheter Ablation",
   "year": 2023,
   "venue": "2023 IEEE International Conference on Robotics and Automation (ICRA)"
  },
  {
   "key": "belikov2024_evolution",
   "doi": "10.1016/j.jestch.2024.101789",
   "url": null,
   "title": "Evolution and current state of robotic catheters for endovascular surgery: A comprehensive review",
   "year": 2024,
   "venue": "Engineering Science and Technology, an International Journal"
  },
  {
   "key": "pescio2025_endovascular",
   "doi": "10.1080/13645706.2025.2454237",
   "url": null,
   "title": "Endovascular robotics: technical advances and future directions",
   "year": 2025,
   "venue": "Minimally Invasive Therapy & Allied Technologies"
  }
 ],
 "read_level": "full",
 "read_level_detail": "full",
 "notes": "Authors applied CC BY to the accepted manuscript; IEEE version is publisher copyright.",
 "maintainers_own": false,
 "found_by": "gap"
}