 "schema_version": 1,
 "id": "harvard_mccath_kesner2011",
 "name": "Motion-comp. catheter",
 "full_name": "Harvard motion-compensation catheter system (voice-coil guidewire drive with 3-D ultrasound servoing)",
 "group": "Harvard SEAS BioRobotics Lab (R. D. Howe; S. B. Kesner)",
 "group_short": "Harvard",
 "family": "academic",
 "category": "academic",
 "first_year": 2011,
 "latest_year": 2014,
 "versions": "2011 ICRA force control of flexible catheter robots for beating-heart surgery (title); 2011 TRO position control with friction and backlash compensation (full, PMC author manuscript); 2014 IJRR robotic catheter cardiac ablation combining 3DUS guidance and force control, new force-sensing RF ablation end effector (full, kesner2014_robotic)",
 "target_anatomy": "intracardiac beating-heart repair (mitral annulus tracking); RF cardiac ablation (kesner2014 Sec. 1-2)",
 "devices": [
  "guidewire",
  "sheath"
 ],
 "devices_driven": "guidewire/instrument sliding in a fixed 85 cm Teflon sheath with steel spring; in vivo 1.5 mm OD guidewire in 1.6 mm ID sheath (TRO 2011 Sec. III, Table I)",
 "n_dof": 1,
 "n_dof_detail": "1 actuated (fast axial translation); bending and rotation by the clinician with conventional catheter controls",
 "translation_mechanism": "other",
 "translation_detail": "other: voice-coil linear actuator (H2W NCC20-18-02-1X, 50.8 mm travel, 26.7 N peak) on a BX3-3 linear ball slide",
 "rotation_mechanism": "none",
 "rotation_detail": "none (manual); pull-wire bending and guidewire twisting proposed as future DOF (Fig. 18)",
 "device_range": "sheath ID 1.59-2.38 mm with guidewire OD 0.76-2.23 mm tested (Table I)",
 "footprint_mm": "N.R.",
 "mass_kg": "N.R.",
 "force_sensing": "LCFD-1KG load cell (10 N range) in the drive measures friction; LP-50F potentiometer for position (TRO 2011); IJRR 2014: catheter-tip force sensor, a reflective surface on perpendicular 0.25 mm NiTi flexures read by a fibre-optic transducer, 3D-printed (Objet Connex500), about 5 mm diameter, integrated with the RF ablation electrode, calibrated against an ATI Mini40 (Sec. 2.2, Figs. 4-5)",
 "haptics_leader": "linear joystick adds commands to the fast axis; no force feedback reported",
 "imaging_compat": "3-D ultrasound (Philips SONOS 7500, epicardial) with GPU Radon-transform tool tracking; EKF compensates 50-100 ms imaging delay",
 "sterility": "N.R.",
 "highest_validation": "animal",
 "validation_detail": "one 75 kg pig, catheter inserted through the top of the left atrium (not through the vasculature), mitral-annulus tracking trials longer than 15 s; number of trials N.R. (TRO 2011 Sec. VII); IJRR 2014: bench force-control runs and water-tank runs under 3DUS against a target moving 12 mm at about 1 Hz (sinusoid and human mitral-annulus trajectory), robotic vs manual Medtronic RF Marinr MCXL catheter (Sec. 4-5, Figs. 16-17)",
 "key_numbers": "in vivo RMS tracking error below 1.0 mm in all trials (0.77 mm shown) vs above 8 mm without compensation; friction compensation up to 2 N; bench MAE 1.28 -> 0.26 mm (inverse compensation, 1 Hz) and 2.34 -> 0.24 mm (model-based); design targets >= 20 mm travel, >= 210 mm/s, >= 3800 mm/s^2, about 4 N (TRO 2011); IJRR 2014: 1 N contact force held on the moving target under 3DUS with 0.08 N RMS error, 97 % less RMS contact-resistance variation than the manual catheter, force control improved motion tracking by about 20 % (Abstract)",
 "sim_model": "none found",
 "has_sim_model": false,
 "sim2real": "none-found",
 "sim2real_detail": "none found",
 "picture": {
  "status": "not-cleared",
  "grade": "B",
  "kind": "render",
  "source": "kesner2011_force Fig. 2 (drive system CAD, p. 2), IEEE ICRA 2011,",
  "source_url": "https://doi.org/10.1109/icra.2011.5979690",
  "licence": "publisher copyright (IEEE)",
  "credit": "Kesner et al., 2011 IEEE International Conference on Robotics and Automation (2011), Fig. 2. publisher copyright (IEEE).",
  "edits": "native extract (embedded 1179 x 526); no crop; nothing erased; none upscaled",
  "file": null
 },
 "pictures": [
  {
   "id": "harvard_mccath_kesner2011_01",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "close-up",
   "caption": "3D-printed optical force sensor at the tip of the catheter guidewire stem",
   "source_key": "kesner2011_force",
   "source": "Kesner et al., 2011 IEEE International Conference on Robotics and Automation (2011), Fig. 4 (photograph), p. 2",
   "source_url": "https://doi.org/10.1109/icra.2011.5979690",
   "where": "Fig. 4 (photograph), p. 2",
   "licence": "publisher copyright (IEEE)"
  },
  {
   "id": "harvard_mccath_kesner2011_02",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "close-up",
   "caption": "Force-sensing RF ablation end effector: solid model and 3D-printed prototype on the guidewire",
   "source_key": "kesner2014_robotic",
   "source": "Kesner et al., The International Journal of Robotics Research (2014), Fig. 4(a), p. 633",
   "source_url": "https://doi.org/10.1177/0278364913511350",
   "where": "Fig. 4(a), p. 633",
   "licence": "publisher copyright"
  },
  {
   "id": "harvard_mccath_kesner2011_03",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "in-use",
   "caption": "Robotic catheter tip on a moving target in the water tank beside the 3DUS probe",
   "source_key": "kesner2014_robotic",
   "source": "Kesner et al., The International Journal of Robotics Research (2014), Fig. 17 (bottom), p. 641",
   "source_url": "https://doi.org/10.1177/0278364913511350",
   "where": "Fig. 17 (bottom), p. 641",
   "licence": "publisher copyright"
  }
 ],
 "sources": [
  {
   "key": "kesner2011_position",
   "doi": "10.1109/tro.2011.2160467",
   "url": null,
   "title": "Position Control of Motion Compensation Cardiac Catheters",
   "year": 2011,
   "venue": "IEEE Transactions on Robotics"
  },
  {
   "key": "kesner2011_force",
   "doi": "10.1109/icra.2011.5979690",
   "url": null,
   "title": "Force control of flexible catheter robots for beating heart surgery",
   "year": 2011,
   "venue": "2011 IEEE International Conference on Robotics and Automation"
  },
  {
   "key": "kesner2014_robotic",
   "doi": "10.1177/0278364913511350",
   "url": null,
   "title": "Robotic catheter cardiac ablation combining ultrasound guidance and force control",
   "year": 2014,
   "venue": "The International Journal of Robotics Research"
  }
 ],
 "read_level": "full",
 "read_level_detail": "full (TRO 2011 via PMC HTML; IJRR 2014, ); title (ICRA 2011)",
 "notes": "Proximal drive for one fast DOF; same Harvard group later built the ICE-steering robot (harvard_ice_loschak2017). Boundary case: transatrial, not transvascular. | 2026-11-08 X3: IJRR 2014 read in full: same drive (voice coil NCC20-18-02-1X on a BX3-3 slide, LP-50F), 85 cm Teflon or Nylon sheath with steel-spring guidewire (Sec. 2); no new animal test (validation stays animal from TRO 2011)",
 "maintainers_own": false,
 "found_by": "gap"
}