 "schema_version": 1,
 "id": "hanyang_crr_kim2023",
 "name": "Hanyang CRR",
 "full_name": "Hanyang/Yonsei master-slave catheter-guidewire driving systems (assembly-type 2016; coaxial controller-responder robot CRR 2023)",
 "group": "Hanyang University (Byung-Ju Yi) with Yonsei University Severance Hospital (Jong Yun Won)",
 "group_short": "Hanyang / Yonsei",
 "family": "commercial",
 "category": "clinical-stage",
 "first_year": 2016,
 "latest_year": 2024,
 "versions": "cha2016_assembly (Proc IMechE H 231(1):69-79, issue 2017, online 2016: assembly-type 4-DOF master-slave, phantom) -> Woo 2019 Appl Sci (5-DOF, haptic) and Song 2021 Appl Sci (in vivo usability), cited by kim2023 refs 14-15, not read -> 2022 its 5-DOF slave used as the guidewire/guide-catheter advancer of DGIST's ECMIS, 2 swine (hwang2022_ecmis p. 8) -> kim2023_robotassisted (JVIR 2023: 7-DOF coaxial controller-responder robot, CRR, human pilot)",
 "target_anatomy": "hepatic arteries for TACE (CRR); arterial phantom (2016)",
 "devices": [
  "guidewire",
  "microcatheter",
  "catheter"
 ],
 "devices_driven": "2016: 5 F catheter and 0.035-in guidewire (cha2016_assembly p. 75); CRR: 5 F catheter, 0.035-in guidewire, 2.2 F microcatheter (Progreat) and 0.014-in micro-guidewire (Meister), 4 devices (kim2023_robotassisted p. 1566-1567); how many move simultaneously N.R.",
 "n_dof": 7,
 "n_dof_detail": "4 (2016: insertion and rotation of catheter and guidewire, cha2016_assembly p. 71); 7 (CRR: insertion and rotation of catheter, guidewire and micro-guidewire, insertion of microcatheter, kim2023_robotassisted p. 1566)",
 "translation_mechanism": "friction-roller",
 "translation_detail": "friction-roller (2016 guidewire: active and passive roller, spring-adjusted friction) plus other: rack-and-pinion carriage that moves the catheter drive (cha2016_assembly p. 72); CRR drive type N.R. (kim2023_robotassisted)",
 "rotation_mechanism": "other",
 "rotation_detail": "2016: plastic gear trains rotate the catheter (Y-connector fixed to the rotation part) and the guidewire roller unit (cha2016_assembly p. 72); CRR N.R.",
 "device_range": "commercially available devices; 2016 catheter drive stroke 460 mm (cha2016_assembly p. 73); CRR 5 F catheter stroke 45 cm, microcatheter stroke 20 cm longer (kim2023_robotassisted p. 1568-1569)",
 "footprint_mm": "N.R.",
 "mass_kg": "N.R.",
 "force_sensing": "Guidewire-tip contact estimated from actuator current, no dedicated sensor: under 200 mA in a straight artery, +300 mA curved, +500 mA blocked (cha2016_assembly p. 76); CRR N.R.",
 "haptics_leader": "2016: 2-DOF parallel-mechanism master (insertion, rotation) with two DC motors for haptic feedback, activate/release and catheter/guidewire mode buttons (cha2016_assembly p. 74); CRR: finger-grip handle with activate/release buttons (kim2023_robotassisted p. 1566), force feedback N.R.",
 "imaging_compat": "2016: camera over a transparent water-filled phantom; CRR: hybrid angio-CT suite (Canon INFX-8000C with Aquilion), robot mounted on the angiotable (kim2023_robotassisted p. 1567, Fig. 2a)",
 "sterility": "Device-contacting parts detach and are EtO-sterilised (all but the roller actuator part), assembly 86 s (cha2016_assembly p. 73, 77); the same for the CRR (kim2023_robotassisted citing cha2016)",
 "highest_validation": "human",
 "validation_detail": "2016: bench (10 insertion trials) and phantom (4 users x 3 trials; survey of 8) (cha2016_assembly); 2022: 2 swine as ECMIS advancer (hwang2022_ecmis); kim2023: single-centre prospective pilot, 10 HCC patients, 5 robot-assisted vs 5 conventional TACE, one operator; technical success 4/5 patients and 7/8 target vessels (one failure: 5 F catheter twisted in the telescope); no procedure-related adverse event",
 "key_numbers": "2016: max insertion error 0.63 mm, max response time 16 ms (cha2016_assembly). CRR: operator dose median 0.4 vs 53.2 uSv (P = .005); patient dose 2,167.5 vs 2,989.7 uSv (P = .311); procedure time median 56 (47-65) vs 37 (30-58) min (P = .101); 8 of 30 TACE steps robotised (abstract; Results: 8 of 22 procedural steps) (kim2023_robotassisted)",
 "sim_model": "none found",
 "has_sim_model": false,
 "sim2real": "none-found",
 "sim2real_detail": "none found",
 "picture": {
  "status": "not-cleared",
  "grade": "B",
  "kind": "photo",
  "source": "kim2023_robotassisted Fig. 1(a) (photo of the 7-DOF CRR responder robot), J Vasc Interv Radiol 2023;34:1565-1574, p. 4,",
  "source_url": "https://doi.org/10.1016/j.jvir.2023.06.004",
  "licence": "publisher copyright (SIR / Elsevier)",
  "credit": "Kim et al., Journal of Vascular and Interventional Radiology (2023), Fig. 1(a). publisher copyright (SIR / Elsevier).",
  "edits": "native extract (embedded 2073 x 2247, panels a-d); cropped to panel a below the three module labels; the label descenders (rows 165-178, x 215-765) replaced by mirrored backdrop rows 179-192; panel letter \"a\" (bottom left, on the backdrop) filled with a smoothed Coons patch of its border (no LaMa); none upscaled",
  "file": null
 },
 "pictures": [
  {
   "id": "hanyang_crr_kim2023_01",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "setup",
   "caption": "Master console and slave robot over the patient in the angiography room",
   "source_key": "song2022_learningbased",
   "source": "Song et al., Journal of Computational Design and Engineering (2022), Fig. 4, J Comput Des Eng 2022 (academic.oup.com view-large 379575173)",
   "source_url": "https://doi.org/10.1093/jcde/qwac074",
   "where": "Fig. 4, J Comput Des Eng 2022 (academic.oup.com view-large 379575173)",
   "licence": "CC BY-NC (article page; version not stated)"
  },
  {
   "id": "hanyang_crr_kim2023_02",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "leader",
   "caption": "Two-DOF joystick master device with mode and activation buttons",
   "source_key": "song2022_learningbased",
   "source": "Song et al., Journal of Computational Design and Engineering (2022), Fig. 17 (view-large 379575229)",
   "source_url": "https://doi.org/10.1093/jcde/qwac074",
   "where": "Fig. 17 (view-large 379575229)",
   "licence": "CC BY-NC (article page; version not stated)"
  },
  {
   "id": "hanyang_crr_kim2023_03",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "setup",
   "caption": "Autonomous setup: slave robot, vascular phantom, RGB camera and control screens",
   "source_key": "song2022_learningbased",
   "source": "Song et al., Journal of Computational Design and Engineering (2022), Fig. 14 (view-large 379575215)",
   "source_url": "https://doi.org/10.1093/jcde/qwac074",
   "where": "Fig. 14 (view-large 379575215)",
   "licence": "CC BY-NC (article page; version not stated)"
  },
  {
   "id": "hanyang_crr_kim2023_04",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "render",
   "caption": "CAD of the 7-DOF responder robot: telescopic support, catheter/guidewire and microcatheter modules",
   "source_key": "kim2023_robotassisted",
   "source": "Kim et al., Journal of Vascular and Interventional Radiology (2023), Fig. 1(b), p. 4",
   "source_url": "https://doi.org/10.1016/j.jvir.2023.06.004",
   "where": "Fig. 1(b), p. 4",
   "licence": "publisher copyright"
  },
  {
   "id": "hanyang_crr_kim2023_05",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "leader",
   "caption": "Controller device: finger-grip handle on a pantograph with insertion and rotation axes",
   "source_key": "kim2023_robotassisted",
   "source": "Kim et al., Journal of Vascular and Interventional Radiology (2023), Fig. 1(c-d), p. 4",
   "source_url": "https://doi.org/10.1016/j.jvir.2023.06.004",
   "where": "Fig. 1(c-d), p. 4",
   "licence": "publisher copyright"
  },
  {
   "id": "hanyang_crr_kim2023_06",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "in-use",
   "caption": "Responder robot mounted on the angiography table over the patient during TACE",
   "source_key": "kim2023_robotassisted",
   "source": "Kim et al., Journal of Vascular and Interventional Radiology (2023), Fig. 2(b), p. 5",
   "source_url": "https://doi.org/10.1016/j.jvir.2023.06.004",
   "where": "Fig. 2(b), p. 5",
   "licence": "publisher copyright"
  },
  {
   "id": "hanyang_crr_kim2023_07",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "in-use",
   "caption": "Assistants at the table and operator at the shielded controller site",
   "source_key": "kim2023_robotassisted",
   "source": "Kim et al., Journal of Vascular and Interventional Radiology (2023), Fig. 2(c-d), p. 5",
   "source_url": "https://doi.org/10.1016/j.jvir.2023.06.004",
   "where": "Fig. 2(c-d), p. 5",
   "licence": "publisher copyright"
  },
  {
   "id": "hanyang_crr_kim2023_08",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "photo",
   "caption": "Four-DOF slave robot of the earlier assembly-type master-slave system",
   "source_key": "song2022_learningbased",
   "source": "Song et al., Journal of Computational Design and Engineering (2022), Fig. 2 (previous main picture; OUP view-large 379575168)",
   "source_url": "https://doi.org/10.1093/jcde/qwac074",
   "where": "Fig. 2 (previous main picture; OUP view-large 379575168)",
   "licence": "CC BY-NC (per the OUP permissions link; version not stated)"
  }
 ],
 "sources": [
  {
   "key": "cha2016_assembly",
   "doi": "10.1177/0954411916679328",
   "url": null,
   "title": "An assembly-type master–slave catheter and guidewire driving system for vascular intervention",
   "year": 2016,
   "venue": "Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine"
  },
  {
   "key": "kim2023_robotassisted",
   "doi": "10.1016/j.jvir.2023.06.004",
   "url": null,
   "title": "Robot-Assisted Transarterial Chemoembolization of Hepatocellular Carcinoma Using a Coaxial Microcatheter Driving Controller-Responder Robot System: Clinical Pilot Study",
   "year": 2023,
   "venue": "Journal of Vascular and Interventional Radiology"
  },
  {
   "key": "hwang2022_ecmis",
   "doi": "10.1002/adhm.202102529",
   "url": null,
   "title": "An Electromagnetically Controllable Microrobotic Interventional System for Targeted, Real-Time Cardiovascular Intervention",
   "year": 2022,
   "venue": "Advanced Healthcare Materials"
  }
 ],
 "read_level": "full",
 "read_level_detail": "full (cha2016_assembly, kim2023_robotassisted)",
 "notes": "kim2023 cites cha2016 (ref. 13) as a previous description of the CRR system ('described in previous studies (13-15)'); the word predecessor is not used. latest_year 2024 is not supported by cha2016 or kim2023 (kim2023 is 2023). Elsevier/SAGE papers received by hand 2026-11-08. F4 2026-10-14: du2024_analyzing (full) uses the SIAT isomorphic primary-secondary robot and never mentions Hanyang; moved to row siat_haptic_duan2025. | X2 2026-11-08: raised to full text; main picture now the CRR itself (kim2023 Fig. 1a).",
 "maintainers_own": false,
 "found_by": "academic"
}