 "schema_version": 1,
 "id": "hamlyn_driver_rafiitari2013",
 "name": "Hamlyn driver",
 "full_name": "Hamlyn hands-on robotic catheter driver for learning from demonstration (pre-CathBot)",
 "group": "Imperial College London, Hamlyn Centre (G.-Z. Yang; H. Rafii-Tari, W. Chi, C. J. Payne, J. Liu, C. Riga, C. Bicknell)",
 "group_short": "Imperial",
 "family": "academic",
 "category": "academic",
 "first_year": 2013,
 "latest_year": 2018,
 "versions": "2012 IROS force-feedback system for catheterisation (Payne, title only); 2013 MICCAI GMM/GMR learning with the driver; 2014 MICCAI hierarchical-HMM cooperative catheterisation; 2018 IJCARS non-rigid-registration trajectory transfer; from 2020 the Hamlyn LfD work runs on CathBot (chi2020_collaborative uses 'the CathBot system')",
 "target_anatomy": "aortic arch cannulation (innominate, left common carotid) in silicone phantoms",
 "devices": [
  "catheter"
 ],
 "devices_driven": "one standard catheter (operator handles the guidewire manually in the 2013 shared-control scheme)",
 "n_dof": 2,
 "n_dof_detail": "2 (axial, rotational)",
 "translation_mechanism": "friction-roller",
 "translation_detail": "friction-roller (pair of friction wheels coupled to one servomotor)",
 "rotation_mechanism": "rotating-drive-unit",
 "rotation_detail": "second servomotor rotates the frame that holds the catheter; two Dynamixel MX-28 servomotors, PID (rafiitari2013 Sec. 2.3; chi2018 Sec. Experiments)",
 "device_range": "N.R.",
 "footprint_mm": "N.R.",
 "mass_kg": "N.R.",
 "force_sensing": "none on the driver; ATI Mini40 6-DOF sensor under the phantom for evaluation (chi2018)",
 "haptics_leader": "hands-on master: proximal position-sensing unit that reads natural catheter motions (two DOF); no force feedback in these papers",
 "imaging_compat": "NDI Aurora 6-DOF EM sensor at the tip; 2-D projected image for the operator",
 "sterility": "N.R.",
 "highest_validation": "phantom",
 "validation_detail": "2013: 12 robotic cannulations per learned model (expert and intermediate) across 4 inexperienced operators; 2018: cross-validation over three type-I aortic-arch phantoms under dry, continuous and pulsatile flow, forces vs four experts",
 "key_numbers": "2018 success 98.1% dry and 94.4% continuous flow; mean contact force -33.3% and force SD -70.6% vs manual (chi2018 abstract)",
 "sim_model": "none found",
 "has_sim_model": false,
 "sim2real": "none-found",
 "sim2real_detail": "none found (policies learned from real phantom demonstrations)",
 "picture": {
  "status": "not-cleared",
  "grade": "B",
  "kind": "photo",
  "source": "payne2012_forcefeedback_IROS Fig. 1 (top photograph: the master-slave force feedback system in situ), IROS 2012",
  "source_url": "https://doi.org/10.1109/iros.2012.6386149",
  "licence": "publisher copyright (IEEE)",
  "credit": "Payne et al., 2012 IEEE/RSJ International Conference on Intelligent Robots and Systems (2012), Fig. 1. publisher copyright (IEEE).",
  "edits": "native extract (1509x686); white margins trimmed to (84,45)-(1426,686); no erasing; not upscaled",
  "file": null
 },
 "pictures": [
  {
   "id": "hamlyn_driver_rafiitari2013_01",
   "status": "cleared",
   "file": "pictures/extra/hamlyn_driver_rafiitari2013_01.jpg",
   "thumb": "pictures/thumbs/hamlyn_driver_rafiitari2013_01.jpg",
   "kind": "setup",
   "caption": "Catheter manipulator at a vascular phantom with flow pumps, camera and EM tracking",
   "source_key": "chi2018_learningbased",
   "source": "Chi et al., International Journal of Computer Assisted Radiology and Surgery (2018), Fig. 4, p. 5",
   "source_url": "https://doi.org/10.1007/s11548-018-1743-5",
   "where": "Fig. 4, p. 5",
   "licence": "CC BY 4.0"
  },
  {
   "id": "hamlyn_driver_rafiitari2013_02",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "in-use",
   "caption": "Cooperative set-up: catheter driver feeding an aortic-arch phantom under camera view",
   "source_key": "rafiitari2014_hierarchical",
   "source": "Rafii-Tari et al., Lecture Notes in Computer Science (2014), Fig. 1(a), p. 5",
   "source_url": "https://doi.org/10.1007/978-3-319-10404-1_62",
   "where": "Fig. 1(a), p. 5",
   "licence": "publisher copyright (Springer LNCS)"
  },
  {
   "id": "hamlyn_driver_rafiitari2013_03",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "setup",
   "caption": "Measurement unit, aortic phantom, proximal position sensor and catheter driving unit",
   "source_key": "rafiitari2013_learningbased",
   "source": "Rafii-Tari et al., Lecture Notes in Computer Science (2013), Fig. 1(a)-(e), p. 4",
   "source_url": "https://doi.org/10.1007/978-3-642-40763-5_46",
   "where": "Fig. 1(a)-(e), p. 4",
   "licence": "publisher copyright (Springer LNCS)"
  },
  {
   "id": "hamlyn_driver_rafiitari2013_04",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "photo",
   "caption": "2012 force-feedback master-slave insertion device held in situ",
   "source_key": "payne2012_force",
   "source": "Payne et al., 2012 IEEE/RSJ International Conference on Intelligent Robots and Systems (2012), Fig. 1 (top), p. 2",
   "source_url": "https://doi.org/10.1109/iros.2012.6386149",
   "where": "Fig. 1 (top), p. 2",
   "licence": "publisher copyright (IEEE)"
  },
  {
   "id": "hamlyn_driver_rafiitari2013_05",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "in-use",
   "caption": "2012 user study: operator at the robotic device with phantom and F/T sensor",
   "source_key": "payne2012_force",
   "source": "Payne et al., 2012 IEEE/RSJ International Conference on Intelligent Robots and Systems (2012), Fig. 6, p. 5",
   "source_url": "https://doi.org/10.1109/iros.2012.6386149",
   "where": "Fig. 6, p. 5",
   "licence": "publisher copyright (IEEE)"
  },
  {
   "id": "hamlyn_driver_rafiitari2013_06",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "render",
   "caption": "Rendering of the 2012 insertion robot: clutch, over-tube discs, master force sensor",
   "source_key": "payne2012_force",
   "source": "Payne et al., 2012 IEEE/RSJ International Conference on Intelligent Robots and Systems (2012), Fig. 2, p. 3",
   "source_url": "https://doi.org/10.1109/iros.2012.6386149",
   "where": "Fig. 2, p. 3",
   "licence": "publisher copyright (IEEE)"
  },
  {
   "id": "hamlyn_driver_rafiitari2013_07",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "render",
   "caption": "CAD of the 2012 device: clutch, master and slave actuators on one slide",
   "source_key": "payne2012_force",
   "source": "Payne et al., 2012 IEEE/RSJ International Conference on Intelligent Robots and Systems (2012), Fig. 1 (bottom, two embedded strips joined), p. 2",
   "source_url": "https://doi.org/10.1109/iros.2012.6386149",
   "where": "Fig. 1 (bottom, two embedded strips joined), p. 2",
   "licence": "publisher copyright (IEEE)"
  }
 ],
 "sources": [
  {
   "key": "rafiitari2013_learningbased",
   "doi": "10.1007/978-3-642-40763-5_46",
   "url": null,
   "title": "Learning-Based Modeling of Endovascular Navigation for Collaborative Robotic Catheterization",
   "year": 2013,
   "venue": "Lecture Notes in Computer Science"
  },
  {
   "key": "rafiitari2014_hierarchical",
   "doi": "10.1007/978-3-319-10404-1_62",
   "url": null,
   "title": "Hierarchical HMM Based Learning of Navigation Primitives for Cooperative Robotic Endovascular Catheterization",
   "year": 2014,
   "venue": "Lecture Notes in Computer Science"
  },
  {
   "key": "chi2018_learningbased",
   "doi": "10.1007/s11548-018-1743-5",
   "url": null,
   "title": "Learning-based endovascular navigation through the use of non-rigid registration for collaborative robotic catheterization",
   "year": 2018,
   "venue": "International Journal of Computer Assisted Radiology and Surgery"
  },
  {
   "key": "payne2012_force",
   "doi": "10.1109/iros.2012.6386149",
   "url": null,
   "title": "A force feedback system for endovascular catheterisation",
   "year": 2012,
   "venue": "2012 IEEE/RSJ International Conference on Intelligent Robots and Systems"
  },
  {
   "key": "chi2020_collaborative",
   "doi": "10.1109/icra40945.2020.9196912",
   "url": null,
   "title": "Collaborative Robot-Assisted Endovascular Catheterization with Generative Adversarial Imitation Learning",
   "year": 2020,
   "venue": "2020 IEEE International Conference on Robotics and Automation (ICRA)"
  }
 ],
 "read_level": "full",
 "read_level_detail": "full (rafiitari2013, rafiitari2014, chi2018); title (Payne 2012)",
 "notes": "Answers A3's open question: the Hamlyn LfD hardware 2013-2018 was this in-house driver, not Sensei/Magellan; Chi 2020 (GAIL) used CathBot.",
 "maintainers_own": false,
 "found_by": "gap"
}