 "schema_version": 1,
 "id": "growing_mangan2025",
 "name": "Growing robot",
 "full_name": "Hybrid tendon-notched continuum robot + hydraulic everting (growing) robot",
 "group": "Morimoto (UCSD) with Hawkes (UCSB), Heit (Stanford)",
 "group_short": "UCSD / UCSB",
 "family": "tip",
 "category": "actuated-device",
 "first_year": 2025,
 "latest_year": 2025,
 "versions": "single (T-MRB 2025); 2021: VINE everting (growing) catheter, UCSB/UCSD/Stanford, same team (Li 2021 T-MRB) (Alekseeva 2025 Table 12 row 9, Fig. 19g) (alekseeva2025_design)",
 "target_anatomy": "neuro: type III aortic arch and extremely tortuous ICA benchtop models (mechanical thrombectomy)",
 "devices": [
  "catheter"
 ],
 "devices_driven": "own growing robot (2.67 mm OD, about 8 Fr) that pulls a commercial 5 Fr aspiration catheter (SOFIA); notched base 7.6 mm OD",
 "n_dof": null,
 "n_dof_detail": "notched base two segments, tendon-driven by 2 capstans; growth by fluid pressure; system roll and insertion",
 "translation_mechanism": "other",
 "translation_detail": "other: eversion by hydraulic pressure (35-40 kPa) plus linear actuator and friction drive for the aspiration catheter",
 "rotation_mechanism": "rotating-drive-unit",
 "rotation_detail": "system roll stage",
 "device_range": "growing robot length 445 mm (S8 citing mangan Sec. III-C)",
 "footprint_mm": "N.R.",
 "mass_kg": "N.R.",
 "force_sensing": "pressure sensor on growth fluid; N.R. for tip force",
 "haptics_leader": "no",
 "imaging_compat": "N.R.",
 "sterility": "N.R.",
 "highest_validation": "phantom",
 "validation_detail": "silicone arch and ICA models with two 360-degree loops of 7.3 mm radius; one full deployment in under 10 min with mock clot (Sec. VI-D, S8); no repeated-trial success rate found",
 "key_numbers": "growth pressure 35-40 kPa; housing withstands 85 kPa; steering error 9.9 +/- 1.2 % and 17.6 +/- 0.7 % of segment length (S8 citing Sec. VI-A); retraction buckles",
 "sim_model": "none found in text scanned (kinematics of notched robot and design optimisation reported; no simulator)",
 "has_sim_model": false,
 "sim2real": "none-found",
 "sim2real_detail": "none found",
 "picture": {
  "status": "not-cleared",
  "grade": "C",
  "kind": "render",
  "source": "mangan2025_serially Fig. 5 (CAD of the watertight actuation subsystem)",
  "source_url": "https://doi.org/10.1109/tmrb.2025.3583160",
  "licence": "publisher copyright (IEEE)",
  "credit": "Mangan et al., IEEE Transactions on Medical Robotics and Bionics (2025), Fig. 5. publisher copyright (IEEE).",
  "edits": "native extract, no edits (labels and leader lines kept: they cross the motors, capstans and housing)",
  "file": null
 },
 "pictures": [
  {
   "id": "growing_mangan2025_01",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "in-use",
   "caption": "Full deployment in a benchtop model: arch, tortuous ICA, mock clot",
   "source_key": "mangan2025_serially",
   "source": "Mangan et al., IEEE Transactions on Medical Robotics and Bionics (2025), Fig. 11, p. 11",
   "source_url": "https://doi.org/10.1109/tmrb.2025.3583160",
   "where": "Fig. 11, p. 11",
   "licence": "publisher copyright"
  },
  {
   "id": "growing_mangan2025_02",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "in-use",
   "caption": "Notched robot and everting growing robot in arch and ICA phantoms",
   "source_key": "mangan2025_serially",
   "source": "Mangan et al., IEEE Transactions on Medical Robotics and Bionics (2025), Fig. 1, p. 2",
   "source_url": "https://doi.org/10.1109/tmrb.2025.3583160",
   "where": "Fig. 1, p. 2",
   "licence": "publisher copyright"
  },
  {
   "id": "growing_mangan2025_03",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "close-up",
   "caption": "Tendon-notched continuum robot in its watertight sleeve, bent",
   "source_key": "mangan2025_serially",
   "source": "Mangan et al., IEEE Transactions on Medical Robotics and Bionics (2025), Fig. 4(f), p. 5",
   "source_url": "https://doi.org/10.1109/tmrb.2025.3583160",
   "where": "Fig. 4(f), p. 5",
   "licence": "publisher copyright"
  },
  {
   "id": "growing_mangan2025_04",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "render",
   "caption": "Drawing of the hybrid tip: notched robot, growing robot, aspiration catheter",
   "source_key": "mangan2025_serially",
   "source": "Mangan et al., IEEE Transactions on Medical Robotics and Bionics (2025), Fig. 4(e), p. 5",
   "source_url": "https://doi.org/10.1109/tmrb.2025.3583160",
   "where": "Fig. 4(e), p. 5",
   "licence": "publisher copyright"
  }
 ],
 "sources": [
  {
   "key": "mangan2025_serially",
   "doi": "10.1109/tmrb.2025.3583160",
   "url": null,
   "title": "Serially-Connected Soft Continuum Robots for Endovascular Emergencies",
   "year": 2025,
   "venue": "IEEE Transactions on Medical Robotics and Bionics"
  },
  {
   "key": "alekseeva2025_design",
   "doi": "10.1002/rob.22480",
   "url": null,
   "title": "The Design of Endovascular Robots for Cardiac Interventions: A Survey",
   "year": 2024,
   "venue": "Journal of Field Robotics"
  }
 ],
 "read_level": "full",
 "read_level_detail": "full text downloaded; abstract, intro, hardware sections read, results via S8",
 "notes": "Affiliations are UCSD/UCSB/Stanford; brief mentioned UCSD/Stanford.",
 "maintainers_own": false,
 "found_by": "actuated-tip"
}