 "schema_version": 1,
 "id": "dupont_teer_pistorius2025",
 "name": "TEER robot",
 "full_name": "Boston Children's robotic drive for transcatheter edge-to-edge mitral repair (MitraClip cartridges on a universal catheter drive)",
 "group": "Boston Children's Hospital / Harvard Medical School (P. E. Dupont; L. Pistorius, N. U. Nayar, P. Tran) with UCSF (S. Elmariah)",
 "group_short": "Boston Children's",
 "family": "academic",
 "category": "academic",
 "first_year": 2025,
 "latest_year": 2026,
 "versions": "2025 arXiv; 2026 RAL; the universal drive itself is announced for a separate letter",
 "target_anatomy": "mitral valve (TEER)",
 "devices": [
  "sheath",
  "therapeutic-device"
 ],
 "devices_driven": "Abbott MitraClip NTR through an Edwards PASCAL Precision transseptal sheath; manual handles replaced by transmission cartridges (Sec. II)",
 "n_dof": 8,
 "n_dof_detail": "8 used (transseptal sheath 3, intermediate sheath 3, device sheath 2); drive supports up to four telescoping sheaths with up to four motorised inputs each",
 "translation_mechanism": "linear-stage+clamp",
 "translation_detail": "linear-stage+clamp (device-agnostic carts translate each cartridge)",
 "rotation_mechanism": "handle-rotation",
 "rotation_detail": "motor-driven worm gears for bending and rotation; clamp on the handle for device-sheath roll",
 "device_range": "procedure-specific cartridges on device-agnostic carts",
 "footprint_mm": "N.R.",
 "mass_kg": "N.R.",
 "force_sensing": "none reported",
 "haptics_leader": "game controller (haptic device input supported by the ROS 2 software)",
 "imaging_compat": "N.R.",
 "sterility": "N.R.",
 "highest_validation": "phantom",
 "validation_detail": "silicone mitral model (United Biologics); one operator; 5 manual and 5 robotic trials per step test; 30 manual and 30 robotic clip deliveries, 10 per segment A1P1, A2P2, A3P3 (Sec. IV)",
 "key_numbers": "segment 2 robotic time 52% of manual; mean clip placement error from 3 mm to below 1 mm for segments 2 and 3; inadvertent clip rotation 28 +- 4 deg manual vs 6 +- 7 deg robotic; speed limits 5.46 deg/s flexure, 14.56 deg/s roll, 6 mm/s translation",
 "sim_model": "none found",
 "has_sim_model": false,
 "sim2real": "none-found",
 "sim2real_detail": "none found",
 "picture": {
  "status": "not-cleared",
  "grade": "C",
  "kind": "photo",
  "source": "pistorius2026_teer_RAL Fig. 4(b) robotic clip delivery system (drive system with three cartridges)",
  "source_url": "https://doi.org/10.1109/lra.2026.3698357",
  "licence": "publisher copyright (IEEE; NIH author manuscript PMC13271658)",
  "credit": "Pistorius et al., IEEE Robotics and Automation Letters (2026), Fig. 4(b). publisher copyright (IEEE; NIH author manuscript PMC13271658).",
  "edits": "native extract (2050x1926); cropped above the label arrow, so the wheels are cut at the bottom; not upscaled",
  "file": null
 },
 "pictures": [
  {
   "id": "dupont_teer_pistorius2025_01",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "in-use",
   "caption": "Robotic clip delivery system at the silicone heart model with game controller",
   "source_key": "pistorius2026_using",
   "source": "Pistorius et al., IEEE Robotics and Automation Letters (2026), Fig. 4(b), p. 5",
   "source_url": "https://doi.org/10.1109/lra.2026.3698357",
   "where": "Fig. 4(b), p. 5",
   "licence": "publisher copyright (IEEE; NIH author manuscript PMC13271658)"
  },
  {
   "id": "dupont_teer_pistorius2025_02",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "photo",
   "caption": "Top view of three cartridges on carts with leadscrews, motors and grippers",
   "source_key": "pistorius2026_using",
   "source": "Pistorius et al., IEEE Robotics and Automation Letters (2026), Fig. 2(c), p. 2",
   "source_url": "https://doi.org/10.1109/lra.2026.3698357",
   "where": "Fig. 2(c), p. 2",
   "licence": "publisher copyright (IEEE; NIH author manuscript PMC13271658)"
  },
  {
   "id": "dupont_teer_pistorius2025_03",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "close-up",
   "caption": "Manual TEER handles beside their robotic cartridges, degrees of freedom colour-coded",
   "source_key": "pistorius2026_using",
   "source": "Pistorius et al., IEEE Robotics and Automation Letters (2026), Fig. 2(a)-(b), p. 2",
   "source_url": "https://doi.org/10.1109/lra.2026.3698357",
   "where": "Fig. 2(a)-(b), p. 2",
   "licence": "publisher copyright (IEEE; NIH author manuscript PMC13271658)"
  },
  {
   "id": "dupont_teer_pistorius2025_04",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "render",
   "caption": "CAD of the cartridge lock clamp and gear connection to the cart",
   "source_key": "pistorius2026_using",
   "source": "Pistorius et al., IEEE Robotics and Automation Letters (2026), Fig. 2(d), p. 2",
   "source_url": "https://doi.org/10.1109/lra.2026.3698357",
   "where": "Fig. 2(d), p. 2",
   "licence": "publisher copyright (IEEE; NIH author manuscript PMC13271658)"
  }
 ],
 "sources": [
  {
   "key": "pistorius2026_using",
   "doi": "10.1109/lra.2026.3698357",
   "url": null,
   "title": "Using Robotics to Improve Transcatheter Edge-to-Edge Repair of the Mitral Valve",
   "year": 2026,
   "venue": "IEEE Robotics and Automation Letters"
  }
 ],
 "read_level": "full",
 "read_level_detail": "full",
 "notes": "Distinct from the Dupont autonomous intracardiac catheter (robots_A3 dupont_fagogenis2019).",
 "maintainers_own": false,
 "found_by": "gap"
}