 "schema_version": 1,
 "id": "dupont_fagogenis2019",
 "name": "Haptic-vision cath.",
 "full_name": "Autonomous intracardiac catheter (haptic vision)",
 "group": "Boston Children's Hospital / Harvard Medical School, Pediatric Cardiac Bioengineering Lab (G. Fagogenis, P. E. Dupont)",
 "group_short": "Boston Children's",
 "family": "academic",
 "category": "academic",
 "first_year": 2019,
 "latest_year": 2019,
 "versions": "2019 Sci Robot",
 "target_anatomy": "transapical aortic paravalvular leak closure (pig)",
 "devices": [
  "catheter"
 ],
 "devices_driven": "its own concentric-tube robotic catheter (three precurved superelastic tubes, OD 2.77 / 2.40 / 1.875 mm, Table 1) carrying the haptic-vision sensor; tools pass through the innermost tube (occluder on a wire inside a delivery cannula, Fig. 6)",
 "n_dof": null,
 "n_dof_detail": "N.R. as a number: the drive rotates and telescopically extends three tubes relative to each other, forming two telescoping sections (Robotic catheter design; Table 1; movie S1)",
 "translation_mechanism": "other",
 "translation_detail": "other: concentric-tube drive at the tube bases rotates and telescopically extends three precurved superelastic tubes (Robotic catheter design)",
 "rotation_mechanism": "other",
 "rotation_detail": "concentric-tube drive rotates each tube at its base (Robotic catheter design)",
 "device_range": "tube OD 1.875-2.77 mm; sensor: 8 mm silicone optical window with 2.5 mm working channel (Table 1; Haptic vision sensor design)",
 "footprint_mm": "N.R.",
 "mass_kg": "N.R.",
 "force_sensing": "no force sensor: tissue contact is inferred from the haptic-vision image (1 mm^3 NanEye CMOS camera + LED in an 8 mm silicone window); tip force set by the contact duty cycle (Fig. 1, Fig. 7)",
 "haptics_leader": "Touch (3D Systems) six-DOF joystick for the teleoperated comparator; force feedback N.R. (Computer software design)",
 "imaging_compat": "tip camera (haptic vision) for navigation; ultrasound monitor in the OR set-up (Fig. 2B); fluoroscopy N.R.",
 "sterility": "drive system draped in plastic in the OR (Fig. 2B); valve and flush system at the inner tube's proximal end keeps air out of the lumen (Robotic catheter design)",
 "highest_validation": "animal",
 "validation_detail": "in vivo, Yorkshire swine 84.3 +- 4.7 kg with a custom leaky bioprosthetic aortic valve, transapical access: apex to annulus 5 animals / 90 autonomous trials (teleop 3 / 9, manual 3 / 13); circumnavigation 3 animals / 65 trials; to the leak 5 animals / 83 trials; occluder deployment 8/11 autonomous, 7/9 teleop, 11/13 manual (Results, In vivo experiments); ex vivo pressurized porcine heart for software testing (Fig. 5)",
 "key_numbers": "autonomous 99% (89/90) apex to annulus; 95% (79/83) to leak; 66% (43/65) for annulus following; time 39+-17 s vs 34+-29 s teleop vs 31+-27 s manual; tip-to-leak distance 3.0 +- 2.0 mm (operator registration) and 2.9 +- 1.5 mm (autonomous) (Results)",
 "sim_model": "none found (a data-replay simulator of recorded in vivo images and trajectories was used to develop the navigation software, Fig. 5; it is not a mechanics model of the robot)",
 "has_sim_model": false,
 "sim2real": "none-found",
 "sim2real_detail": "none found",
 "picture": {
  "status": "not-cleared",
  "grade": "C",
  "kind": "photo",
  "source": "https://www.therobotreport.com/wp-content/uploads/2019/04/kinematicControl.jpg (lead image of https://www.therobotreport.com/robotic-catheter-brings-autonomous-navigation-into-the-human-body/; credit Pediatric Cardiac Bioengineering Lab, Boston Children's Hospital)",
  "source_url": "https://www.therobotreport.com/wp-content/uploads/2019/04/kinematicControl.jpg",
  "licence": "press image",
  "credit": "https://www.therobotreport.com/wp-content/uploads/2019/04/kinematicControl.jpg (lead image of https://www.therobotreport.com/robotic-catheter-brings-autonomous-navigation-into-the-human-body/; credit Pediatric Cardiac Bioengineering Lab, Boston Children's Hospital). Licence: press image.",
  "edits": "full-size JPEG 2048x1536; cropped; not upscaled",
  "file": null
 },
 "pictures": [
  {
   "id": "dupont_fagogenis2019_01",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "in-use",
   "caption": "Draped catheter drive system at a porcine heart, joystick and graphical interface",
   "source_key": "fagogenis2019_autonomous",
   "source": "Fagogenis et al., Science Robotics (2019), Fig. 2(B), author manuscript (PMC image nihms-1035499-f0002.jpg, 800 px)",
   "source_url": "https://doi.org/10.1126/scirobotics.aaw1977",
   "where": "Fig. 2(B), author manuscript (PMC image nihms-1035499-f0002.jpg, 800 px)",
   "licence": "publisher copyright (AAAS; NIH author manuscript PMC6693882)"
  },
  {
   "id": "dupont_fagogenis2019_02",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "close-up",
   "caption": "The three pre-curved concentric tubes of the robotic catheter",
   "source_key": "fagogenis2019_autonomous",
   "source": "Fagogenis et al., Science Robotics (2019), Fig. 4(C), author manuscript (PMC image nihms-1035499-f0004.jpg, 800 px)",
   "source_url": "https://doi.org/10.1126/scirobotics.aaw1977",
   "where": "Fig. 4(C), author manuscript (PMC image nihms-1035499-f0004.jpg, 800 px)",
   "licence": "publisher copyright (AAAS; NIH author manuscript PMC6693882)"
  },
  {
   "id": "dupont_fagogenis2019_03",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "close-up",
   "caption": "Haptic-vision sensor at the catheter tip beside a US cent coin",
   "source_key": "fagogenis2019_autonomous",
   "source": "Fagogenis et al., Science Robotics (2019), Fig. 1(A), p. 2",
   "source_url": "https://doi.org/10.1126/scirobotics.aaw1977",
   "where": "Fig. 1(A), p. 2",
   "licence": "publisher copyright"
  },
  {
   "id": "dupont_fagogenis2019_04",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "photo",
   "caption": "Fabricated concentric-tube catheter with sensor inside a 3D-printed heart model",
   "source_key": "fagogenis2019_autonomous",
   "source": "Fagogenis et al., Science Robotics (2019), Fig. 4(B), p. 7",
   "source_url": "https://doi.org/10.1126/scirobotics.aaw1977",
   "where": "Fig. 4(B), p. 7",
   "licence": "publisher copyright"
  }
 ],
 "sources": [
  {
   "key": "fagogenis2019_autonomous",
   "doi": "10.1126/scirobotics.aaw1977",
   "url": null,
   "title": "Autonomous robotic intracardiac catheter navigation using haptic vision",
   "year": 2019,
   "venue": "Science Robotics"
  }
 ],
 "read_level": "full",
 "read_level_detail": "full (fagogenis2019_autonomous,, hand-downloaded 2026-11-08)",
 "notes": "Tip-actuated catheter: overlaps agent A5; listed because it was named in the brief. Coordinator may drop. | 2026-11-08 X3: full text read. Correction: translation_mechanism tendon/tip-actuation -> other: concentric-tube drive (the paper builds the catheter as a concentric tube robot, no tendons); the drive sits on a passively adjustable frame on the OR table",
 "maintainers_own": false,
 "found_by": "academic"
}