 "schema_version": 1,
 "id": "csio_gupta2025",
 "name": "CSIO cardiac robot",
 "full_name": "CSIR-CSIO robot-assisted cardiac catheterization system",
 "group": "CSIR-Central Scientific Instruments Organisation and AcSIR (N. Gupta, R. Jha)",
 "group_short": "CSIR-CSIO",
 "family": "academic",
 "category": "academic",
 "first_year": 2025,
 "latest_year": 2025,
 "versions": "single report (gupta2025_hybrid)",
 "target_anatomy": "cardiac catheterization (bench)",
 "devices": [
  "catheter"
 ],
 "devices_driven": "catheter",
 "n_dof": 2,
 "n_dof_detail": "2 (translation + rotation)",
 "translation_mechanism": "other",
 "translation_detail": "other: roller-, gear- and belt-pulley mechanisms (abstract)",
 "rotation_mechanism": "other",
 "rotation_detail": "stepper-driven, 0.9 deg per pulse",
 "device_range": "N.R.",
 "footprint_mm": "N.R.",
 "mass_kg": "N.R.",
 "force_sensing": "spring-loaded force dynamics model; sensor N.R.",
 "haptics_leader": "surgeon-centric control panel for bidirectional manipulation",
 "imaging_compat": "N.R.",
 "sterility": "N.R.",
 "highest_validation": "bench",
 "validation_detail": "feed-forward PID tracking tests (gupta2025_hybrid abstract)",
 "key_numbers": "translation about 1 mm/s (0.060 rad/s), rotation 0.98 rad/s at 0.9 deg/pulse; displacement RMSE < 0.017 mm (R2 0.999), rotation RMSE < 0.11 deg, overshoot < 1% (gupta2025_hybrid abstract)",
 "sim_model": "none found",
 "has_sim_model": false,
 "sim2real": "none-found",
 "sim2real_detail": "none found",
 "picture": {
  "status": "not-cleared",
  "grade": "C",
  "kind": "photo",
  "source": "gupta2025_design Fig. 2(b) (prototype photo), IEEE T-MRB 7(1) 2025, doi:10.1109/TMRB.2024.3503911",
  "source_url": "https://doi.org/10.1109/TMRB.2024.3503911",
  "licence": "publisher copyright (IEEE)",
  "credit": "Gupta et al., IEEE Transactions on Medical Robotics and Bionics (2025), Fig. 2(b). publisher copyright (IEEE).",
  "edits": "native extract (2717 x 3455); cropped to panel (b) without the panel letter and the bottom label row; label text lying on the plain white background painted white (9 rectangles, no inpainting model); not upscaled",
  "file": null
 },
 "pictures": [
  {
   "id": "csio_gupta2025_01",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "in-use",
   "caption": "Top view of both drives feeding a catheter into arterial replicas",
   "source_key": "gupta2025_design",
   "source": "Gupta et al., IEEE Transactions on Medical Robotics and Bionics (2025), Fig. 11, p. 9",
   "source_url": "https://doi.org/10.1109/tmrb.2024.3503911",
   "where": "Fig. 11, p. 9",
   "licence": "publisher copyright (IEEE)"
  },
  {
   "id": "csio_gupta2025_02",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "close-up",
   "caption": "Axial drive: spring-loaded roller pairs and gear train gripping the catheter",
   "source_key": "gupta2025_catheter",
   "source": "Gupta et al., 2025 International Conference on Innovation and Intelligence for Informatics, Computing, and Technologies (3ICT) (2025), Fig. 3, p. 3",
   "source_url": "https://doi.org/10.1109/3ict68299.2025.11442127",
   "where": "Fig. 3, p. 3",
   "licence": "publisher copyright (IEEE)"
  },
  {
   "id": "csio_gupta2025_03",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "close-up",
   "caption": "Rotational drive with its cover on, top view",
   "source_key": "gupta2025_catheter",
   "source": "Gupta et al., 2025 International Conference on Innovation and Intelligence for Informatics, Computing, and Technologies (3ICT) (2025), Fig. 2, p. 3",
   "source_url": "https://doi.org/10.1109/3ict68299.2025.11442127",
   "where": "Fig. 2, p. 3",
   "licence": "publisher copyright (IEEE)"
  },
  {
   "id": "csio_gupta2025_04",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "render",
   "caption": "Labelled CAD drawing of the two-drive catheter robot",
   "source_key": "gupta2025_design",
   "source": "Gupta et al., IEEE Transactions on Medical Robotics and Bionics (2025), Fig. 2(a), p. 4",
   "source_url": "https://doi.org/10.1109/tmrb.2024.3503911",
   "where": "Fig. 2(a), p. 4",
   "licence": "publisher copyright (IEEE)"
  }
 ],
 "sources": [
  {
   "key": "gupta2025_hybrid",
   "doi": "10.1177/09544119251385276",
   "url": null,
   "title": "Hybrid control algorithm for precision motion in robot-assisted cardiac catheterization",
   "year": 2025,
   "venue": "Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine"
  }
 ],
 "read_level": "abstract",
 "read_level_detail": "abstract",
 "notes": "",
 "maintainers_own": false,
 "found_by": "gap"
}