 "schema_version": 1,
 "id": "cobot_kim2026",
 "name": "Cobot guidewire",
 "full_name": "Intravascular collaborative robotic (Cobot) magnetic guidewire",
 "group": "DGIST (Daegu Gyeongbuk Institute of Science and Technology) and its spin-off IMsystem, with UMass Amherst, EPFL and Kyungpook National University (kim2026_magnetic affiliations, read by P6 from PMC13410658); 2022 ECMIS: DGIST (Hongsoo Choi, PI), Hanyang University ERICA (Byung-Ju Yi, advancer), Seoul National University Bundang Hospital, Seoul St. Mary's Hospital and ETH Zurich (hwang2022_ecmis p. 1, 14)",
 "group_short": "DGIST",
 "family": "magnetic",
 "category": "magnetic-navigation",
 "first_year": 2022,
 "latest_year": 2026,
 "versions": "2022 ECMIS (hwang2022_ecmis, Adv. Healthc. Mater.): eight-coil hemispherical electromagnetic actuation system under a carbon-composite bed, biplane C-arms, magnetic tip on a 0.014-in wire, Hanyang 5-DOF master-slave advancer, 2 swine -> 2026 Cobot guidewire (kim2026_magnetic): 8-coil system with IMsystem, phantom and swine. The link is inferred from the shared DGIST / IMsystem authors (S. Jeon, J.-y. Kim) and the eight-coil design; ECMIS is not named 'Cobot'; 2018-19: DGIST (S. Jeon, H. Choi) magnetic soft guidewire tip steered in MiniMag (Jeon 2018 Micro Nano Syst. Lett.) and OctoMag (Jeon 2019 Soft Robot.), phantoms (Hwang 2020 Figs. 7a-b; Konda 2025 Table 2 row 3) (hwang2020_review; konda2025_robotically)",
 "target_anatomy": "neuro (2026, phantom and swine); coronary, iliac and renal arteries (2022 ECMIS, swine)",
 "devices": [
  "guidewire",
  "catheter"
 ],
 "devices_driven": "2026: guidewire with permanent magnet and magnetic polymer tip, tip OD 0.4 mm (kim2026_magnetic, per P6 notes); 2022: 400 um x 10 mm tip unit (3 mm NdFeB magnet + magnetic polymer in a silicone tube) on a 0.014-in Fielder FC guidewire; the advancer moves the guidewire and a 6 F guiding catheter (hwang2022_ecmis p. 4, 8, 12)",
 "n_dof": null,
 "n_dof_detail": "2022: coil system gives 5-DOF magnetic control (3 translation, 2 rotation); advancer = Hanyang 5-DOF slave robot used for insertion and retraction (hwang2022_ecmis p. 8); 2026 N.R.",
 "translation_mechanism": "magnetic",
 "translation_detail": "magnetic (steering); 2022 insertion by the motorised master-slave advancer (hwang2022_ecmis p. 8)",
 "rotation_mechanism": "magnetic-field",
 "rotation_detail": "field direction",
 "device_range": "2022: tip steers over 90 degrees at 5-15 mT (hwang2022_ecmis p. 4)",
 "footprint_mm": "2022 coil workspace about 15 x 15 x 15 cm3 at up to 15 mT (hwang2022_ecmis p. 8); 2026: 150 mm cube of open volume with a uniform-field 52 mm cube, 30 mT used (kim2026_magnetic, per P6 notes)",
 "mass_kg": "N.R.",
 "force_sensing": "N.R.",
 "haptics_leader": "2022: C++/Qt GUI from a shielded control booth, haptics N.R. (hwang2022_ecmis p. 8)",
 "imaging_compat": "2022: biplane C-arms (floor and ceiling) with flat-panel detectors; the X-ray beam passes a central hole in the coil array; no electromagnetic interference observed (hwang2022_ecmis p. 8, 12)",
 "sterility": "N.R.",
 "highest_validation": "animal",
 "validation_detail": "2026: phantom (n = 7) and swine (n = 11) procedures vs a manual wire (kim2026_magnetic, per P6 notes); 2022: 2D phantom on OctoMag (4 repeats), 3D silicone phantom (3 repeats), 2 crossbred pigs (about 30 kg): iliac, circumflex and LAD with an artificial occlusion in swine 1, renal in swine 2; access by hand, then teleoperated by engineers (hwang2022_ecmis p. 6-13)",
 "key_numbers": "2026: procedure time 49.57 +- 19.61 vs 103.29 +- 68.18 s manual in phantom (p = 0.085), 22.36 +- 7.09 vs 79.63 +- 49.07 s in swine (p = 0.0033) (kim2026_magnetic, per P6 notes); 2022: friction coefficient 10.68 -> 0.09; 3D phantom right-coronary target 26 +- 4.04 s; operator dose rate in the booth < 11 uSv/h (hwang2022_ecmis)",
 "sim_model": "2022: analytical Euler-Bernoulli tip model solved by Newton-Raphson (hwang2022_ecmis p. 13); no simulator",
 "has_sim_model": true,
 "sim2real": "none-found",
 "sim2real_detail": "none found",
 "picture": {
  "status": "not-cleared",
  "grade": "C",
  "kind": "render",
  "source": "https://imsystem.kr/images/pathfinder_navi.jpg (alt \"Pathfinder_Navi product image\"), page https://imsystem.kr/products#pathfinder",
  "source_url": "https://imsystem.kr/images/pathfinder_navi.jpg",
  "licence": "press image",
  "credit": "https://imsystem.kr/images/pathfinder_navi.jpg (alt \"Pathfinder_Navi product image\"), page https://imsystem.kr/products#pathfinder. Licence: press image.",
  "edits": "palette PNG with transparency composited on white; cropped with 4 % margin",
  "file": null
 },
 "pictures": [
  {
   "id": "cobot_kim2026_01",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "render",
   "caption": "Electromagnetic coil unit (IM_SUPERMAG_CLINIC) with its ring of coil cores",
   "source_key": "imsystem2026_pathfinder-navi_BROCHURE",
   "source": "imsystem2026_pathfinder-navi_BROCHURE, brochure p. 2, \"Electromagnetic coils\" panel (also",
   "source_url": "https://imsystem.kr/products",
   "where": "brochure p. 2, \"Electromagnetic coils\" panel (also https://imsystem.kr/products)",
   "licence": "press image"
  },
  {
   "id": "cobot_kim2026_02",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "setup",
   "caption": "Coil unit placed under the patient table of a C-arm room (illustration)",
   "source_key": "https://imsystem.kr/images/pathfinder_overview_v2_en.png",
   "source": "https://imsystem.kr/images/pathfinder_overview_v2_en.png, products page, \"Surgical room & coils under the bed\" panel",
   "source_url": null,
   "where": "products page, \"Surgical room & coils under the bed\" panel",
   "licence": "press image"
  },
  {
   "id": "cobot_kim2026_03",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "leader",
   "caption": "Remote control station outside the X-ray room (illustration)",
   "source_key": "imsystem2026_pathfinder-navi_BROCHURE",
   "source": "imsystem2026_pathfinder-navi_BROCHURE, brochure p. 2, \"Remote control\" panel",
   "source_url": null,
   "where": "brochure p. 2, \"Remote control\" panel",
   "licence": "press image"
  },
  {
   "id": "cobot_kim2026_04",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "in-use",
   "caption": "Coil system in a catheterisation laboratory",
   "source_key": "web:imsystem.kr",
   "source": "imsystem.kr, company page (P6 ctx picture)",
   "source_url": null,
   "where": "company page (P6 ctx picture)",
   "licence": "press image"
  },
  {
   "id": "cobot_kim2026_05",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "render",
   "caption": "ECMIS (2022, same DGIST group): biplane C-arms, coils under the bed, advancer, shielded booth",
   "source_key": "hwang2022_ecmis",
   "source": "Hwang et al., Advanced Healthcare Materials (2022), Fig. 1(D), p. 3",
   "source_url": "https://doi.org/10.1002/adhm.202102529",
   "where": "Fig. 1(D), p. 3",
   "licence": "publisher copyright"
  },
  {
   "id": "cobot_kim2026_06",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "setup",
   "caption": "ECMIS (2022): eight-coil electromagnetic actuation system integrated under the surgical bed",
   "source_key": "hwang2022_ecmis",
   "source": "Hwang et al., Advanced Healthcare Materials (2022), Fig. 4(A), p. 9",
   "source_url": "https://doi.org/10.1002/adhm.202102529",
   "where": "Fig. 4(A), p. 9",
   "licence": "publisher copyright"
  },
  {
   "id": "cobot_kim2026_07",
   "status": "not-cleared",
   "file": null,
   "thumb": null,
   "kind": "in-use",
   "caption": "ECMIS (2022) in vivo set-up: swine on the bed, advancer, ceiling C-arm, control booth",
   "source_key": "hwang2022_ecmis",
   "source": "Hwang et al., Advanced Healthcare Materials (2022), Fig. 5(A), p. 10",
   "source_url": "https://doi.org/10.1002/adhm.202102529",
   "where": "Fig. 5(A), p. 10",
   "licence": "publisher copyright"
  }
 ],
 "sources": [
  {
   "key": "kim2026_magnetic",
   "doi": "10.1002/adhm.71365",
   "url": null,
   "title": "Magnetic Control of Intravascular Collaborative Robotic (Cobot) Guidewire: Neurovascular Intervention Studies in Phantom and Swine Models",
   "year": 2026,
   "venue": "Advanced Healthcare Materials"
  },
  {
   "key": "hwang2022_ecmis",
   "doi": "10.1002/adhm.202102529",
   "url": null,
   "title": "An Electromagnetically Controllable Microrobotic Interventional System for Targeted, Real-Time Cardiovascular Intervention",
   "year": 2022,
   "venue": "Advanced Healthcare Materials"
  },
  {
   "key": "hwang2020_review",
   "doi": "10.1007/s11370-020-00311-0",
   "url": null,
   "title": "A review of magnetic actuation systems and magnetically actuated guidewire- and catheter-based microrobots for vascular interventions",
   "year": 2020,
   "venue": "Intelligent Service Robotics"
  },
  {
   "key": "konda2025_robotically",
   "doi": "10.1126/scirobotics.adt7461",
   "url": null,
   "title": "Robotically steerable guidewires—Current trends and future directions",
   "year": 2025,
   "venue": "Science Robotics"
  }
 ],
 "read_level": "full",
 "read_level_detail": "full (hwang2022_ecmis); kim2026_magnetic full HTML via P6 notes (not re-read by X2)",
 "notes": "Group and 2026 numbers from P6_gallery.md section 4 (PMC13410658 full HTML). ECMIS (2022) added as the predecessor system by inference; first_year 2026 -> 2022 rests on that inference. | X2 2026-11-08. | X4 2026-11-08: first_year marked (inferred): ECMIS (hwang2022_ecmis) taken as the predecessor from shared authors and the 8-coil design; no text states the link",
 "maintainers_own": false,
 "found_by": "actuated-tip"
}