{
 "schema_version": 1,
 "id": "asan_choi2021",
 "name": "Asan PCI robot",
 "full_name": "Asan Medical Center modular bi-motional roller-cartridge PCI robot",
 "group": "Asan Medical Center, University of Ulsan College of Medicine (Jaesoon Choi; Dept. of Cardiology, Young-Hak Kim; Dept. of Convergence Medicine, Youngjin Moon) (choi2021_vascular p. 1)",
 "group_short": "Asan Med. Center",
 "family": "commercial",
 "category": "clinical-stage",
 "first_year": 2021,
 "latest_year": 2021,
 "versions": "choi2021_vascular (Biosensors 2021); 2017-18: Asan (J. Choi) EP platform driving a commercial ablation (steerable) catheter with rolling belts, leader with a 3-RRR planar manipulator (Moon 2018), ex vivo phantom (Hu 2017) (Alekseeva 2025 Table 3 row 7, Fig. 8f; Belikov 2024 Fig. 5 HU1) (alekseeva2025_design; belikov2024_evolution); 2020-21: Asan (J. Choi, Y.-H. Kim) cardiac-ablation catheter robot: dual-gripper front module inserts and rotates the catheter without slip, handle module turns the bending knob, Jacobian updated from two position sensors on the catheter (Lee 2021 J. Mech. Robot. 13, doi:10.1115/1.4048224) (Belikov 2024 Fig. 5 LE) (lee2021_design; belikov2024_evolution); 2021: deep RL (Rainbow) guidewire navigation trained and tested on the physical 2-D and 3-D coronary phantoms with an Asan robotic module whose opposed roller pair advances the wire and whose vertical roller shift rotates it, step 0.4 mm or 33 deg (Kweon 2021 IEEE Access; Konda 2025 control row 33); real-world training, not sim-to-real (kweon2021_deep; konda2025_robotically)",
 "target_anatomy": "coronary (PCI)",
 "devices": [
  "guidewire",
  "catheter",
  "therapeutic-device"
 ],
 "devices_driven": "three modules drive a guiding catheter, a guidewire and a balloon catheter (Sec. 2.1.2, p. 3), 3 devices at once; the clamping also fits guide extensions and IVUS catheters (p. 2); bench devices 5 F catheter, 0.014-in guidewire, 3.5 x 15 mm balloon (p. 10); in vivo only the guidewire was robot-driven (p. 13-16)",
 "n_dof": 8,
 "n_dof_detail": "8 by our sum (paper gives no total): guiding-catheter and guidewire modules 3-DOF each (clamp, translate, rotate), balloon module 2-DOF (choi2021_vascular Sec. 2.1.2, p. 3)",
 "translation_mechanism": "friction-roller",
 "translation_detail": "friction-roller (tightly pressed roller pairs, 20 mm rollers driven through bevel gears) (choi2021_vascular Sec. 2.1.1, p. 2-3)",
 "rotation_mechanism": "rotating-clamp",
 "rotation_detail": "Roller pair rubs the device: a motor, bevel gear and ball screw raise the cartridge frame; limited range of about 900-1800 degrees from a 25 mm vertical displacement (Sec. 2.3.2, p. 7); clamping by motor, timing belt and bidirectional ball screw (p. 4)",
 "device_range": "accommodates instruments of various sizes via the active clamping mechanism; rotation range about 900-1800 degrees per cartridge stroke (p. 7); translation stroke and speeds N.R.",
 "footprint_mm": "N.R.",
 "mass_kg": "N.R.",
 "force_sensing": "none: no force sensor; the haptic cue is a virtual wall near the cartridge rotation limit, computed from cartridge position (choi2021_vascular Discussion, p. 17)",
 "haptics_leader": "master: 3-RRR planar parallel mechanism + linear actuator ('clutch-like trigger') + spherical wrist mechanism, called a 6-DOF mechanism (Sec. 2.1.3, p. 4-5; p. 17), Maxon DC motors; force feedback used only as a virtual wall",
 "imaging_compat": "real-time fluoroscopy on the console monitors; physician behind radiation-shielded glass (choi2021_vascular p. 5, Fig. 17b)",
 "sterility": "roller cartridge designed as a disposable part (p. 4); sterile drapes and detachable sterilised rollers form the sterile interface, no closed housing (p. 15, 17)",
 "highest_validation": "human",
 "validation_detail": "bench: 20 cartridge-gap trials, 10 repetitions per translation length and per 360-degree rotation; phantom: EVE silicone model, trial count N.R.; animal: one 60 kg pig, robot-driven guidewire into the RCA; clinical: 2 patients (coronary angiography), robot-driven guidewire to the LAD and the RCA, both technically successful; MFDS approval 20190064902 (choi2021_vascular p. 9-16)",
 "key_numbers": "translation mean error: guiding catheter -0.93 to 0.75 mm, guidewire 0.11-0.86 mm, balloon 0.07-0.57 mm (Table 1); rotation error at 360 degrees: guiding catheter 3.29 +- 5.48, guidewire 1.93 +- 2.50 degrees (Table 2) (choi2021_vascular)",
 "sim_model": "none found",
 "has_sim_model": false,
 "sim2real": "none-found",
 "sim2real_detail": "none found",
 "picture": {
  "status": "cleared",
  "grade": "B",
  "kind": "photo",
  "source": "choi2021_vascular Fig. 12 (phantom setup for PCI), Biosensors 2021, image https://mdpi-res.com/biosensors/biosensors-11-00329/article_deploy/html/images/biosensors-11-00329-g012.png",
  "source_url": "https://doi.org/10.3390/bios11090329",
  "licence": "CC BY 4.0",
  "credit": "Choi et al., Biosensors (2021), Fig. 12. CC BY 4.0.",
  "edits": "MDPI web images (2815x1631, 3426x1310); main cropped, one leader line + its dot over the wall/pole and a text fragment at the edge removed (OpenCV Telea)",
  "file": "pictures/asan_choi2021.jpg"
 },
 "pictures": [
  {
   "id": "asan_choi2021_01",
   "status": "cleared",
   "file": "pictures/extra/asan_choi2021_01.jpg",
   "thumb": "pictures/thumbs/asan_choi2021_01.jpg",
   "kind": "photo",
   "caption": "Clinical prototype: master console with haptic device and slave robot end-effector",
   "source_key": "choi2021_vascular",
   "source": "Choi et al., Biosensors (2021), Fig. 5",
   "source_url": "https://doi.org/10.3390/bios11090329",
   "where": "Fig. 5 (https://mdpi-res.com/biosensors/biosensors-11-00329/article_deploy/html/images/biosensors-11-00329-g005.png)",
   "licence": "CC BY 4.0"
  },
  {
   "id": "asan_choi2021_02",
   "status": "cleared",
   "file": "pictures/extra/asan_choi2021_02.jpg",
   "thumb": "pictures/thumbs/asan_choi2021_02.jpg",
   "kind": "in-use",
   "caption": "Clinical trial: team at the table and operator at the master console",
   "source_key": "choi2021_vascular",
   "source": "Choi et al., Biosensors (2021), Fig. 17",
   "source_url": "https://doi.org/10.3390/bios11090329",
   "where": "Fig. 17 (https://mdpi-res.com/biosensors/biosensors-11-00329/article_deploy/html/images/biosensors-11-00329-g017.png)",
   "licence": "CC BY 4.0"
  },
  {
   "id": "asan_choi2021_03",
   "status": "cleared",
   "file": "pictures/extra/asan_choi2021_03.jpg",
   "thumb": "pictures/thumbs/asan_choi2021_03.jpg",
   "kind": "setup",
   "caption": "Roller module with EM tracker and Aurora field generator beside a phantom",
   "source_key": "choi2021_vascular",
   "source": "Choi et al., Biosensors (2021), Fig. 11",
   "source_url": "https://doi.org/10.3390/bios11090329",
   "where": "Fig. 11 (https://mdpi-res.com/biosensors/biosensors-11-00329/article_deploy/html/images/biosensors-11-00329-g011.png)",
   "licence": "CC BY 4.0"
  },
  {
   "id": "asan_choi2021_04",
   "status": "cleared",
   "file": "pictures/extra/asan_choi2021_04.jpg",
   "thumb": "pictures/thumbs/asan_choi2021_04.jpg",
   "kind": "render",
   "caption": "Renderings of the slave side and master side with labelled parts",
   "source_key": "choi2021_vascular",
   "source": "Choi et al., Biosensors (2021), Fig. 1",
   "source_url": "https://doi.org/10.3390/bios11090329",
   "where": "Fig. 1 (https://mdpi-res.com/biosensors/biosensors-11-00329/article_deploy/html/images/biosensors-11-00329-g001.png)",
   "licence": "CC BY 4.0"
  },
  {
   "id": "asan_choi2021_05",
   "status": "cleared",
   "file": "pictures/extra/asan_choi2021_05.jpg",
   "thumb": "pictures/thumbs/asan_choi2021_05.jpg",
   "kind": "render",
   "caption": "CAD of the end-effector modules for guidewire, catheter and balloon",
   "source_key": "choi2021_vascular",
   "source": "Choi et al., Biosensors (2021), Fig. 2",
   "source_url": "https://doi.org/10.3390/bios11090329",
   "where": "Fig. 2 (https://mdpi-res.com/biosensors/biosensors-11-00329/article_deploy/html/images/biosensors-11-00329-g002.png)",
   "licence": "CC BY 4.0"
  },
  {
   "id": "asan_choi2021_06",
   "status": "cleared",
   "file": "pictures/extra/asan_choi2021_06.jpg",
   "thumb": "pictures/thumbs/asan_choi2021_06.jpg",
   "kind": "close-up",
   "caption": "CAD of the bi-motional roller cartridge, roller module and clamping drive",
   "source_key": "choi2021_vascular",
   "source": "Choi et al., Biosensors (2021), Fig. 3",
   "source_url": "https://doi.org/10.3390/bios11090329",
   "where": "Fig. 3 (https://mdpi-res.com/biosensors/biosensors-11-00329/article_deploy/html/images/biosensors-11-00329-g003.png)",
   "licence": "CC BY 4.0"
  },
  {
   "id": "asan_choi2021_07",
   "status": "cleared",
   "file": "pictures/extra/asan_choi2021_07.jpg",
   "thumb": "pictures/thumbs/asan_choi2021_07.jpg",
   "kind": "leader",
   "caption": "CAD of the haptic master device: spherical, linear and planar mechanisms",
   "source_key": "choi2021_vascular",
   "source": "Choi et al., Biosensors (2021), Fig. 4",
   "source_url": "https://doi.org/10.3390/bios11090329",
   "where": "Fig. 4 (https://mdpi-res.com/biosensors/biosensors-11-00329/article_deploy/html/images/biosensors-11-00329-g004.png)",
   "licence": "CC BY 4.0"
  },
  {
   "id": "asan_choi2021_08",
   "status": "cleared",
   "file": "pictures/extra/asan_choi2021_08.jpg",
   "thumb": "pictures/thumbs/asan_choi2021_08.jpg",
   "kind": "in-use",
   "caption": "Catheter steered to two targets in a vascular phantom, image sequence",
   "source_key": "choi2021_vascular",
   "source": "Choi et al., Biosensors (2021), Fig. 13",
   "source_url": "https://doi.org/10.3390/bios11090329",
   "where": "Fig. 13 (https://mdpi-res.com/biosensors/biosensors-11-00329/article_deploy/html/images/biosensors-11-00329-g013.png)",
   "licence": "CC BY 4.0"
  }
 ],
 "sources": [
  {
   "key": "choi2021_vascular",
   "doi": "10.3390/bios11090329",
   "url": null,
   "title": "A Vascular Intervention Assist Device Using Bi-Motional Roller Cartridge Structure and Clinical Evaluation",
   "year": 2021,
   "venue": "Biosensors"
  },
  {
   "key": "alekseeva2025_design",
   "doi": "10.1002/rob.22480",
   "url": null,
   "title": "The Design of Endovascular Robots for Cardiac Interventions: A Survey",
   "year": 2024,
   "venue": "Journal of Field Robotics"
  },
  {
   "key": "belikov2024_evolution",
   "doi": "10.1016/j.jestch.2024.101789",
   "url": null,
   "title": "Evolution and current state of robotic catheters for endovascular surgery: A comprehensive review",
   "year": 2024,
   "venue": "Engineering Science and Technology, an International Journal"
  },
  {
   "key": "lee2021_design",
   "doi": "10.1115/1.4048224",
   "url": null,
   "title": "Design and Control of a Robotic Steering Mechanism for Electrophysiological Catheters",
   "year": 2020,
   "venue": "Journal of Mechanisms and Robotics"
  },
  {
   "key": "kweon2021_deep",
   "doi": "10.1109/access.2021.3135277",
   "url": null,
   "title": "Deep Reinforcement Learning for Guidewire Navigation in Coronary Artery Phantom",
   "year": 2021,
   "venue": "IEEE Access"
  },
  {
   "key": "konda2025_robotically",
   "doi": "10.1126/scirobotics.adt7461",
   "url": null,
   "title": "Robotically steerable guidewires—Current trends and future directions",
   "year": 2025,
   "venue": "Science Robotics"
  }
 ],
 "read_level": "full",
 "read_level_detail": "full (choi2021_vascular)",
 "notes": "Jaesoon Choi also appears with LN Robotics (maker of commercial AVIAR, A4 scope); a precursor relationship is plausible but not stated in the abstract. | X2 2026-11-08: full text read: no mention of LN Robotics or AVIAR (no company named, no conflict of interest declared); the 'force feedback' of the abstract is a virtual wall without a force sensor; humans: 2 patients, guidewire only.",
 "maintainers_own": false,
 "found_by": "academic"
}
